{"manifest":[{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"17058253","datemodified":"2021-01-08T13:45:54","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"e65213de0a42651709fa9895d3e0bf0f","name":"kmod-qlgc-fastlinq-8.55.5.0-1.rhel8u2.x86_64.rpm","release":"2021-01-08T13:07:05","revision":"0","sha1sum":"8c3dacb7713ce78d88f63baa949fefe536e533e4","size":"16MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.5.0-1"},{"bytes":"17657981","datemodified":"2021-01-08T13:38:51","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"d3a0e5775332af17940f777e30ebb6c0","name":"kmod-qlgc-fastlinq-8.55.5.0-2.rhel8u3.x86_64.rpm","release":"2021-01-08T13:07:05","revision":"0","sha1sum":"a70514c4487d53c8937434778ddd11ba11e29118","size":"16MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.5.0-1"}],"id":{"product":"fac6c21a4a1e47499a956ff93dccfbd6","version":"a667fb329020427aab645ab7a92dd413"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat&nbsp; Enterprise Linux Server&nbsp;8 update 1.</li>\n\t<li>This product now adds PCIe Advanced Error Recovery (AER) support</li>\n\t<li>This product now supports RoCE bonding mode</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which system crash after unloading and reloading only roce driver</li>\n\t<li>This product corrects an issue which VF RDMA system crash in overnight reboot test on multiple VMs</li>\n\t<li>This product corrects an issue which VMs crash randomly upon advanced property disable/enable with Max VFs enumerated on all PFs</li>\n\t<li>This product corrects an issue which iSCSI BFS system fails to reboot if one port is down and reboot is attempted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 3 and 8 update 2</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for Windows Server 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3375360","datemodified":"2020-12-16T14:12:25","file_list":["cp045156.xml","cpqsetup.exe","hbcpssssefd3.rel","payload.json","setup.dll"],"md5sum":"3a42864d76fbfabf0b8a9e5e21125b73","name":"cp045156.exe","release":"2020-12-16T14:04:05","revision":"0","sha1sum":"8f25d316965c81a99da4d69e1df0bd043d60f42a","size":"3MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"dab6093d4d7545e892501476a1f6d448","version":"1387201922974cc1af042d05cbc58648"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-10T05:39:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This release corrects logical block address mismatches that could results in partial or total data loss.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD4"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD4"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5772361","datemodified":"2020-12-13T16:15:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/CP045857.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/SCIMARRNNSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045857.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045857.scexe"],"md5sum":"7a1a97c6403e6973d65d83a7ad868ec4","name":"firmware-hdd-adb3ab8147-HPD4-2.1.x86_64.rpm","release":"2020-12-13T16:03:07","revision":"0","sha1sum":"3c0748b487f30d8420f3d0c55e3c515bfe40e2ea","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"6559625804344daab70667e2f1b0b044","version":"e8e50297b9dd4dccb457e9d35033faad"},"installation":{"command":"CP043262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T18:54:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5928760","datemodified":"2020-10-29T15:48:49","file_list":["SignedImageInstaller64.dll","U14_2.80_10_16_2020.signed.flash","cp046131.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"65054195686d74263dcefd2a423a4048","name":"cp046131.exe","release":"2020-10-29T15:32:05","revision":"0","sha1sum":"d495beb3f7ed5766609e87d9ef451128f7b9164c","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"393089474d234baf8404a8ee98140881","version":"fa817827e0b3422e97e551d8dc246c9c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL170r/XL190r Gen9（U14）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T20:12:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4202043","datemodified":"2021-01-09T01:55:19","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbe","./lib/modules/4.12.14-195-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"d1f70e5e63da2fda09436a12f425d73a","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-09T01:41:06","revision":"0","sha1sum":"5fa47f6c761b6dcfdb1e37dffe942e9668156bd8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4991618","datemodified":"2021-01-09T01:48:23","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"d1651a61c2617b38617329e54b764119","name":"hp-ixgbe-kmp-default-5.9.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-09T01:41:06","revision":"0","sha1sum":"86dc6251243e1624cfc93a22e082c9d6a081fc9c","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"3ab4de78da484144892d6ddcd8fd9b97","version":"7cba14b9508d40b3ae58ccf25ec8ceea"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VR000150GWEPP および VR000480GWEPR ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.&nbsp;</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15750438","datemodified":"2021-01-28T14:05:44","file_list":["/CP045691_BUILD_3.data","/CP045691.vmexe","/CP045691.vmexe64","/CP045691.vmfile","/CP045691_VMw.zip","/CP045691.xml","/payload.json","/CP045691_VMw.zip/index.xml","/CP045691_VMw.zip/vendor-index.xml","/CP045691_VMw.zip/metadata.zip","/CP045691_VMw.zip/vib20/CP045691/HPE_bootbank_CP045691_HPG1.3-7.0.0.15843807.vib","/CP045691_VMw.zip/metadata.zip/vendor-index.xml","/CP045691_VMw.zip/metadata.zip/vmware.xml","/CP045691_VMw.zip/metadata.zip/vibs/CP045691--7816885282568183564.xml","/CP045691_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045691_HPG1.3-7.0.0.15843807.xml"],"md5sum":"6492b36f9e2cc368340edd229f8b78b8","name":"CP045691.zip","release":"2021-01-28T14:03:04","revision":"0","sha1sum":"da476a27e961d061af97ac8498805f2fcde6ed87","size":"15MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1","vib_list":[{"name":"CP045691","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"dbdc578953024bf9bb26afb2d6d4cd6a","version":"891be3a8fce947598fd565f62994d3c7"},"installation":{"command":"CP040667.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:26:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.Â </li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB8000JFECQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5650859","datemodified":"2020-12-13T14:30:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/CP045447.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/SMKRPSD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045447.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045447.scexe"],"md5sum":"e28841f3e354b20364d294a462fdad3f","name":"firmware-hdd-252770cdda-HPD7-6.1.x86_64.rpm","release":"2020-12-13T14:19:04","revision":"0","sha1sum":"dba057eef8feee14bb91144dd9d8814f0c5a1b41","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"cf9ee3d9e8f04b18823882812129b4e0","version":"a380b1d743374d0ab10a6718cab5b423"},"installation":{"command":"CP040301.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5575640","datemodified":"2019-01-22T15:53:42","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/CP038805.xml","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/U24_1.60_01_22_2018.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u24-1.60_2018_01_22-2.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038805.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP038805.scexe"],"md5sum":"9f4b55abf38b05b8f3c035f38d9d6ae7","name":"firmware-system-u24-1.60_2018_01_22-2.1.i386.rpm","release":"2019-01-22T21:52:01","revision":"0","sha1sum":"094b7fc7276d268cd68a1d13e589e09e1e826587","size":"5MB","target_guids":[],"type_of_change":"2","version":"1.60_01-22-2018"}],"id":{"product":"195ed5d18cb04288998708cea17b124d","version":"1de8a7dd85014090b70a94394a614cc4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL260a Gen9/XL2x260w (U24) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL260a Gen9/XL2x260w (U24)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-22T21:35:28","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. The revision of the microcode included in this System ROM does NOT have issues with more frequent reboots and unpredictable system behavior which impacted the previous Intel microcode which was part of the Spectre Variant 2 mitigation. Additional information is available from Intel&rsquo;s Security Exploit Newsroom, <a href=\"https://newsroom.intel.com/press-kits/security-exploits-intel-products/\">https://newsroom.intel.com/press-kits/security-exploits-intel-products/</a>.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Updated the Intel processor microcode to the latest version.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.60(B) contains updates to the component packaging and is functionally equivalent to ver. 1.60. It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the firmware to version 1.60.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. The revision of the microcode included in this System ROM does NOT have issues with more frequent reboots and unpredictable system behavior which impacted the previous Intel microcode which was part of the Spectre Variant 2 mitigation. Additional information is available from Intel&rsquo;s Security Exploit Newsroom, <a href=\"https://newsroom.intel.com/press-kits/security-exploits-intel-products/\">https://newsroom.intel.com/press-kits/security-exploits-intel-products/</a>.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Updated the Intel processor microcode to the latest version.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"}],"sw_keys":[{"name":"U24","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30116","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30052","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 10/25GbE 2P SFP28 MCX512F, HPE 10/25GbE 2P SFP28 MCX562A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter on ESXi 6.5"},{"lang":"ja","x_late":"このパッケージには、ESXi 6.5上のHPE 10GbE 2P SFP + MCX4121A、HPE 10GbE 2p SFP + MCX4621A OCP3、HPE 10/25GbE 2P SFP28 MCX512F、HPE 10/25GbE 2P SFP28 MCX562A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプターをアップグレードするためのユーティリティとバイナリが含まれています"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (P13188-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (P10112-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"36485932","datemodified":"2021-02-03T03:04:41","file_list":["/CP045140.vmexe","/CP045140.vmfile","/CP045140_VMw.zip","/CP045140.xml","/payload.json","/README.txt","/CP045140_VMw.zip/index.xml","/CP045140_VMw.zip/vendor-index.xml","/CP045140_VMw.zip/metadata.zip","/CP045140_VMw.zip/vib20/CP045140/HPE_bootbank_CP045140_1.0.1-6.5.0.4240417.vib","/CP045140_VMw.zip/metadata.zip/vendor-index.xml","/CP045140_VMw.zip/metadata.zip/vmware.xml","/CP045140_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045140_1.0.1-6.5.0.4240417.xml","/CP045140_VMw.zip/metadata.zip/vibs/CP045140-1448046837180798026.xml"],"md5sum":"33eabe17916d2cdf47f980dbf2d2cb8c","name":"CP045140.zip","release":"2021-02-03T03:10:05","revision":"0","sha1sum":"14011b07124eba0f3196fcd7f723afe2853683d1","size":"34MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30116","a6b1a447-382a-5a4f-15B3-101715B30052","a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.4","vib_list":[{"name":"CP045140","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"432284a4a7d540b6ab240935dd40f590","version":"662daac797f047d5b31b4cfd6b334e67"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 6.5）"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:55:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.27.4000:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.27.2008:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>New Feature and Changes in Version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.29.1016:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<p><strong>New Feature and Changes in Version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Ethernet wqe_too_small Mode: A per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats:</li>\n\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused packets to drop due to header size issues and/or failing checks. This issue was caused due to a Linux issue that caused VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) might take longer than when MKEY_BY_NAME was disabled.</li>\n\t<li>In rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>An issue that caused the device to go to dead IRISC as one of the firmware semaphores could not be released when a speed change or port state change was triggered.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the eth_wqe_too_small counter to count ODP page faults.</li>\n\t<li>A low performance was observed after enabling the RoCE Accelerator capability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5768873","datemodified":"2021-01-28T08:21:33","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"7602891bc03deb871595c891b2681201","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u9.x86_64.rpm","release":"2021-01-28T07:53:07","revision":"0","sha1sum":"477ff49f5d70a8150239641fa746cae48c761a40","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"6227fd0bddb244e4842587fb56f2e5ab","version":"25695862758646df99223672f0eab786"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n                   <br/>\n                    # rpm -Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。  </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                      # rpm -e kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial driver for RedHat Enterprise Linux Server&nbsp;7 update&nbsp;8 version&nbsp;10.01.00.64.07.6-k1a</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"584577","datemodified":"2021-01-28T10:15:26","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"efd6c2200e73b72fe7b439007e986986","name":"elx-lpfc-kmp-default-12.8.352.11_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-28T10:06:10","revision":"0","sha1sum":"1960d2e0b97b142e73420df30b19a307495fa399","size":"570KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"83fed5e4a427414fb0792283dd57ec37","version":"62bc5eaa23ef4d089893fce919a6c61d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.20</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB8000JFECQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n      HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>    <br />\n      None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3793256","datemodified":"2020-12-16T16:28:07","file_list":["cp045558.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPSD7.rel"],"md5sum":"cd686232345f1e4e0fe0d65e0e938305","name":"cp045558.exe","release":"2020-12-16T16:21:04","revision":"0","sha1sum":"527dcfcc30e3caec86972dcce90383cdd0b57f7d","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"b23cbcef087a471c988db0eccfc20ffd","version":"79c1738548ae47adb3d91555ea24d00e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:52:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp043545.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp043596.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.2.0"}]},"DirectoryScan":false,"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"\n This component provides updated IE firmware that can be installed directly on supported Operating Systems.\n "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3854943","datemodified":"2020-03-25T20:06:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/CP043594.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/cp043545.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/cp043545.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/cp043596.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/cp043596.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.2.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043594.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043594.scexe"],"md5sum":"7f4ce8705900b8d23408c792fee26bd1","name":"firmware-iegen10-0.2.2.0-1.1.x86_64.rpm","release":"2020-04-01T00:00:00","revision":"1","sha1sum":"ffcb54c3e5022a0f47827357d0f5421be47dfc5e","size":"3MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.2.0"}],"id":{"product":"05f0508175404d989c50e4f9a4e09a23","version":"c7019b92936b44c4b1998df780ffcc6f"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p><br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-07-12T03:59:51","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None  <P><B>Firmware Dependencies:</B></P>None  <P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where Processor or Memory temperature reporting may not be collected properly by the platform and the system fans may be running faster than expected. This issue has been seen occasionally after a server reboot and is typically corrected with a subsequent server reboot. <P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<P><B>Important Notes:</B></P>None  <P><B>Firmware Dependencies:</B></P>None  <P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where Processor or Memory temperature reporting may not be collected properly by the platform and the system fans may be running faster than expected. This issue has been seen occasionally after a server reboot and is typically corrected with a subsequent server reboot. <P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"Smart Storage Administrator CLI (智慧型儲存管理員 CLI (SSACLI) 是一款基於命令列的磁碟組態程式，可用於設定、管理、診斷及監控 Smart Array 控制器，以及現在的主機匯流排介面卡 (HBA)、儲存控制器等其他儲存裝置和 SCSI Express 磁碟機、SAS 交換器裝置等將來的裝置。SSASCRIPTING - 在線上或離線環境中均可執行指令碼處理。SSA Scripting 應用程式有 2 種指令碼處理模式 – 擷取和輸入。"},{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. \n\nSSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."},{"lang":"ko","x_late":"스마트 스토리지 관리자 CLI(SSACLI)는 명령줄 기반의 디스크 구성 프로그램으로 스마트 어레이 컨트롤러와 호스트 버스 어댑터(HBAs)와 같은 기타 저장 장치, 스토리지 컨트롤러, SCSI Express 드라이버와 같은 미래 장치 및 SAS 스위치 장치를 구성, 관리, 진단 및 감시합니다. SSASCRIPTING - 스크립팅은 오프라인 또는 온라인 환경에서 수행될 수 있습니다. SSA 스크립팅 응용 프로그램에는 2개의 스크립팅 모드(캡처 및 입력)가 있습니다."},{"lang":"cn","x_late":"Smart Storage Administrator CLI (SSACLI)是一款基于命令行的磁盘配置程序，可帮助您配置、管理、诊断和监控智能阵列控制器，且现在还可支持其他存储设备，如主机总线适配器（HBA）、存储控制器，未来还可支持 SCSI Express 驱动器以及 SAS 交换机设备。SSASCRIPTING - 离线或在线环境中均可执行脚本处理。SSA Scripting应用有两种脚本处理模式—捕获和输入。"},{"lang":"ja","x_late":"Smart Storage Administrator CLI(SSACLI) は、Smartアレイコントローラーや他のストレージデバイス、例えばホストバスアダプター(HBA)、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。SSASCRIPTING - スクリプトは、オフラインまたはオンライン環境で実行することができます。SSAスクリプティングアプリケーションは、2つのスクリプティングモード - CaptureおよびInputを持っています。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16386609","datemodified":"2021-01-26T19:59:25","file_list":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-5.10-44.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"md5sum":"37382e415838efdab9b2de4e3361e853","name":"ssacli-5.10-44.0.x86_64.rpm","release":"2021-01-26T19:50:13","revision":"0","sha1sum":"2ce928052016a2362736541966f37d2f4151726f","size":"15MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"type_of_change":"0","version":"5.10.44.0"}],"id":{"product":"51c52bf006bd4c60b09797563ff886bf","version":"ac75ab6c9d9e4f8e8522e30feda93f57"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-22T15:24:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2035211","datemodified":"2020-12-02T16:06:06","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"b8403c268dc39dd8d0bd959cf554882e","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp1.x86_64.rpm","release":"2020-12-02T14:22:07","revision":"0","sha1sum":"4c2e0c74af9087834ac18a1deedb1f3d3a1c3ed3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"},{"bytes":"1980634","datemodified":"2020-12-02T16:08:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/compat","./lib/modules/4.12.14-195-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-195-default/updates/drivers","./lib/modules/4.12.14-195-default/updates/drivers/infiniband","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-195-default/updates/drivers/net","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/i915.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/kvmgt.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/mdev.ko","./lib/modules/4.12.14-195-default/updates/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/4.12.14-195-default/updates/net","./lib/modules/4.12.14-195-default/updates/net/9p","./lib/modules/4.12.14-195-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/rds","./lib/modules/4.12.14-195-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"18372d86af11e5c6654e32974521d382","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_195-OFED.4.9.2.2.4.1.sles15sp1.x86_64.rpm","release":"2020-12-02T14:22:07","revision":"0","sha1sum":"1cc3e577c1e7c851cb60e3f5b6edacc344590940","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"}],"id":{"product":"ecc46179b9da4907abbf4738a44b1dc2","version":"16bba50e634d45d9b60de2834208dcc7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-195-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp1.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_195-OFED.4.9.2.2.4.1.sles15sp1.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP1 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for SUSE LINUX Enterprise Server 15 SP1 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15913065","datemodified":"2021-01-28T13:17:44","file_list":["/CP045687_BUILD_4.data","/CP045687.vmexe","/CP045687.vmexe64","/CP045687.vmfile","/CP045687_VMw.zip","/CP045687.xml","/payload.json","/CP045687_VMw.zip/index.xml","/CP045687_VMw.zip/vendor-index.xml","/CP045687_VMw.zip/metadata.zip","/CP045687_VMw.zip/vib20/CP045687/HPE_bootbank_CP045687_HPG1.4-7.0.0.15843807.vib","/CP045687_VMw.zip/metadata.zip/vendor-index.xml","/CP045687_VMw.zip/metadata.zip/vmware.xml","/CP045687_VMw.zip/metadata.zip/vibs/CP045687--7018534880474534748.xml","/CP045687_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045687_HPG1.4-7.0.0.15843807.xml"],"md5sum":"3600eaad43bff76a1a936fd5c94a66f1","name":"CP045687.zip","release":"2021-01-28T13:14:05","revision":"0","sha1sum":"a23d0b6f95f218995d78f8a21bc23a0a2f3e4cfd","size":"15MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045687","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"c565c3f6bc0f4964b8b59efe8bfdfdea","version":"522ca652661446d0b9a16e8a69874b27"},"installation":{"command":"CP040528.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:23:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"13587704","datemodified":"2021-02-16T06:00:13","file_list":["CHIF/","CHIF/X64/","cp039984.exe","cp039985.exe","cp040013.exe","cp041932.exe","cp044589.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"md5sum":"923bc8b1d5d538f0a8df69dabb86e0e1","name":"cp044589.exe","release":"2021-02-16T05:56:05","revision":"0","sha1sum":"ac6ae67737fd9f0f2eb748a779a502af60e2432d","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f36672a","20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"type_of_change":"1","version":"2.8.0.0"}],"id":{"product":"8fe22752c5324386870794853904b4ba","version":"a23006bfb53f41f48196f7696b780a3d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ol>\n\t<li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>\n\t<li>Change to the directory.</li>\n\t<li>Run the .exe file by double-clicking it. A dialog box will display.</li>\n\t<li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-16T09:37:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpsut.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\HPSUT\\bin"},{"name":"sut.exe","sw_key_expectedpath":"%ProgramFiles%\\SUT\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1749929","datemodified":"2021-01-22T05:09:02","file_list":["./opt/emulex/sles15sp1/i386/lib/libdfc.so","./opt/emulex/sles15sp1/i386/lib/libdfc.so.12","./opt/emulex/sles15sp1/i386/lib/libdfc.so.12.8.316","./opt/emulex/sles15sp1/i386/lib/libemsdm.so","./opt/emulex/sles15sp1/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp1/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp1/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp1/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/sles15sp1/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp1/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.316","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"ac161d9dde2e9afd76233d1516326f47","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.sles15sp1.x86_64.rpm","release":"2021-01-22T05:04:49","revision":"0","sha1sum":"a18525024475517f41ab5a6e391923ef7167e03b","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"},{"bytes":"1749924","datemodified":"2021-01-22T05:13:03","file_list":["./opt/emulex/sles15sp2/i386/lib/libdfc.so","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12.8.316","./opt/emulex/sles15sp2/i386/lib/libemsdm.so","./opt/emulex/sles15sp2/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/sles15sp2/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp2/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.316","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"4acde23cfce5ac856819ef4deb38ff96","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.sles15sp2.x86_64.rpm","release":"2021-01-22T05:04:49","revision":"0","sha1sum":"19496f72e10829b2a9aa2ee544b907b765cc7f87","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"3a4168637f45404b864aa9e998210305","version":"aeb879adcbac43ab850b8ca21745c4c1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;1 and SuSE Linux Enterprise Server 15 service pack&nbsp;2 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --reinstall &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.6.272.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MM1000JFJTH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17182669","datemodified":"2021-01-28T09:16:06","file_list":["/CP045675_BUILD_3.data","/CP045675.vmexe","/CP045675.vmexe64","/CP045675.vmfile","/CP045675_VMw.zip","/CP045675.xml","/payload.json","/CP045675_VMw.zip/index.xml","/CP045675_VMw.zip/vendor-index.xml","/CP045675_VMw.zip/metadata.zip","/CP045675_VMw.zip/vib20/CP045675/HPE_bootbank_CP045675_HPD3.3-7.0.0.15843807.vib","/CP045675_VMw.zip/metadata.zip/vendor-index.xml","/CP045675_VMw.zip/metadata.zip/vmware.xml","/CP045675_VMw.zip/metadata.zip/vibs/CP045675--5727768239009976385.xml","/CP045675_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045675_HPD3.3-7.0.0.15843807.xml"],"md5sum":"cfa4817c8d824a9125f824c04bfa4859","name":"CP045675.zip","release":"2021-01-28T09:13:07","revision":"0","sha1sum":"140f35f5e4b3d02100dd2584df1d91e316481b2e","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"0","version":"HPD3","vib_list":[{"name":"CP045675","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"4aaa1b96312a4790820f2c40ac3eb0e7","version":"f0051d86bc2c4ee8b6032d4db68c3727"},"installation":{"command":"CP040517.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000JFJTHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:14:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"サポートされているHPE Mellanoxアダプターカード用のHPE Mellanox MFTドライバーおよびFirmware Tool。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"19947","datemodified":"2021-02-09T16:50:03","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/mst_pci.ko","./lib/modules/4.12.14-195-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"8d980db51d5f2be88ec806cf620f5a31","name":"kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-02-09T16:38:05","revision":"0","sha1sum":"daf477ce232860966a19ff8f794604bacb8cae3d","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"},{"bytes":"8915939","datemodified":"2021-02-09T16:51:14","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"74691541fdefb2556c8c4dd0e215326c","name":"mft-4.16.0-105.sles15sp1.x86_64.rpm","release":"2021-02-09T16:38:05","revision":"0","sha1sum":"79d6f45575d4f6d9f3d150d4779e859c450d9f80","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"}],"id":{"product":"eb8218bf97ea450eb1b29a8724433034","version":"f8e9174a5e9e4083a79418a5528d2a39"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-195-default kernel or any future errata:</p>\n\n<p><strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_195-1.sles15sp1.x86_64.rpm&nbsp;&nbsp;mft-4.16.0-105.sles15sp1.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP1 (AMD64/EM64T)"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15 SP1（AMD64/EM64T）向けのHPE Mellanox MFTドライバーおよびFirmware Tools"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6204296","datemodified":"2020-12-13T12:53:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/CP045422.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/HLEBHasseFG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045422.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045422.scexe"],"md5sum":"844361c74b9c2770faeee8153a50d333","name":"firmware-hdd-41cdb1c9da-HPG2-4.1.x86_64.rpm","release":"2020-12-13T12:41:08","revision":"0","sha1sum":"32652daab703c35a992e198feebea6a61d2a48fc","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"fc2945bc3e5744fea9d120a012546560","version":"612d986245eb418180a1c9d3fea5c419"},"installation":{"command":"CP041508.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_29_1016-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter(P25960-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000437</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6177129","datemodified":"2021-02-25T13:32:26","file_list":["22_29_1016-MCX623106AS-CDA_Ax.pldm.signed","22_29_1016-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"md5sum":"d06c0d6b5d40c20c1bae51c29cfd16fe","name":"22_29_1016-MCX623106AS-CDA_Ax.pldm.fwpkg","release":"2021-02-25T13:29:05","revision":"0","sha1sum":"fd7e93b7d8eaa200bdce66a2699e89de4a6c312e","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"type_of_change":"1","version":"22.29.1016"}],"id":{"product":"23c569ea92fb47f091a7a0c891acff72","version":"c4e0b2f63e954d2fbb210fe9b7a28c51"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-11T11:41:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Optimized vDPA performance for PPS in scalability of up to 127 devices per port.</li>\n\t<li>When using a Multi-Host device, the firmware can now discover who is the external SmartNIC host (the Embedded CPU PF (ECPF) ) with the highest index that is responsible for performing offload activities to the adapter card</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Eye-Opening: supported only when using NRZ signal. (Beta)</li>\n\t<li>Option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order. To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command and set DPP relevant attributes.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>Error statistics and reporting for vDPA.</li>\n\t<li>IPv6 TSO offload.&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR</li>\n\t<li>&quot;iperf3&quot; and&nbsp;&quot;iperf3 -l 512&quot;&nbsp; issue fixed&nbsp;from having traffic for virtio hardware offload solution .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12887322","datemodified":"2020-11-23T11:54:53","file_list":["/CP042237_BUILD_8.data","/CP042237.vmexe","/CP042237.vmexe64","/CP042237.vmfile","/CP042237_VMw.zip","/CP042237.xml","/payload.json","/CP042237_VMw.zip/index.xml","/CP042237_VMw.zip/vendor-index.xml","/CP042237_VMw.zip/metadata.zip","/CP042237_VMw.zip/vib20/CP042237/HPE_bootbank_CP042237_2021.02.01.8-6.7.0.7535516.vib","/CP042237_VMw.zip/metadata.zip/vendor-index.xml","/CP042237_VMw.zip/metadata.zip/vmware.xml","/CP042237_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042237_2021.02.01.8-6.7.0.7535516.xml","/CP042237_VMw.zip/metadata.zip/vibs/CP042237-4177491982784332693.xml"],"md5sum":"01d344b1e556d858d61d925e32fb2537","name":"CP042237.zip","release":"2020-11-23T11:51:04","revision":"0","sha1sum":"b0a0b35c5bf7e12520e63a545f462201fd92445b","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042237","version":"2021.02.01.8-6.7.0.7535516"}]}],"id":{"product":"783998957ee142cfa68787b55e3611e4","version":"351ca9dbbe71465f92bbe5e648d929bc"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:22:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1309248","datemodified":"2021-01-08T22:13:14","file_list":["cp045023.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"e4c2977a5b8a1dcd3ed692b18e728026","name":"cp045023.exe","release":"2021-01-08T21:59:05","revision":"0","sha1sum":"19774932e25be9335853164b1971ff5b9dc1cd70","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"683278c3722a411eb75e30e9eb4f543d","version":"817cd10a4a464dbd952f0d6cfd33ee30"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel iavf Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1889","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-188980860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1889","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"iavf68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该 Smart Component 可为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for ESXi&nbsp;- Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp;&nbsp;Added support fro the ESXI OS7.0</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22923663","datemodified":"2020-08-28T05:27:47","file_list":["/CP045345.vmexe","/CP045345.vmexe64","/CP045345.vmfile","/CP045345.xml","/payload.json","/README.txt"],"md5sum":"1246181ea75df164e87dc1ea7c8a9c4c","name":"CP045345.zip","release":"2020-08-28T05:15:05","revision":"0","sha1sum":"55be01a6ec914e38f762b8392ba947ca18719c96","size":"21MB","target_guids":[],"type_of_change":"1","version":"5.02","vib_list":[]}],"id":{"product":"fe91742b3a574fb18dfddbbd9fae74ba","version":"12a40ca3f52e478c8bb3262962e84383"},"installation":{"command":"CP045345.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp; &nbsp;or&nbsp;chmod +x CPXXXXX.vmexe64 (for ESXi7.0)</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp;or ./CPXXXXX.vmexe64 (for ESXi7.0)</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array P230i, P430, P431, P731m, P830i, and P830"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-24T10:45:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for the ESXI OS7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for the ESXI OS7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103c","sw_key_expectedpath":"firmware"},{"name":"1923103c","sw_key_expectedpath":"firmware"},{"name":"1922103c","sw_key_expectedpath":"firmware"},{"name":"1924103c","sw_key_expectedpath":"firmware"},{"name":"1921103c","sw_key_expectedpath":"firmware"},{"name":"1926103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP220i, P222, P420i, P420, P421, P721m, およびP822のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;8.00&nbsp;&nbsp;&nbsp;<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved accuracy of drive temperature reporting feature</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>\n\t<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n </p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     8.32<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     8.00   <br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     8.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved accuracy of drive temperature reporting feature</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>\n\t<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>\n"}],"files":[{"bytes":"8755941","datemodified":"2017-10-16T11:58:55","file_list":["./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/.hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/746374726C00.firmware.bin.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/747365700069443232323073620076312E303200.Baz-102.fuf.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/CP033363.xml","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/d2220sb.bin.fw","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-46a4d957a7-8.32-1.1/libhpsetup.so","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP033363.scexe"],"md5sum":"a6aa4e791e8c7c75f48492747b43a9a2","name":"hp-firmware-smartarray-46a4d957a7-8.32-1.1.x86_64.rpm","release":"2017-11-02T00:00:00","revision":"1","sha1sum":"c16cb85556b60d704312f03122665e5bf4a95431","size":"8MB","target_guids":[],"type_of_change":"1","version":"8.32"}],"id":{"product":"8e395b40b6dc47ff9696c46179cb8065","version":"1a1af9dc05eb4548a8669347b5620e98"},"installation":{"command":"CP033363.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The&nbsp;CP033363.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-46a4d957a7-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP033363.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-46a4d957a7-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hp.com/go/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>.  </em>This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location</li>\n\t<li>The CP033363.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands: </li>\n</ul>\n\n<p>               # ./CP033363.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</p>\n\n<p>               # <em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*' location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>This extracts the contents of the rpm to 'usr' folder in the current directory</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-smartarray-46a4d957a7-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-smartarray-46a4d957a7-*' folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hp.com/go/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"Linux (x64)版补充更新 /在线ROM刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m和P822"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-12-08T09:36:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved accuracy of drive temperature reporting feature</p>\n","latest_fixes_x_late":"<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n"},{"curr_enhancements_x_late":"<p>Improved accuracy of drive temperature reporting feature</p>\n","curr_fixes_x_late":"<p>System can potentially stop responding with no lockup code due to livelock condition where the RAID Stack thread is polling a queue for a completion to be returned by the base code firmware</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"953242","datemodified":"2021-01-14T07:50:15","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"6fa6a3fa29370b649c57c14326e6961a","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"034c8b07afcca0dc9fe2c1da7864a70ef57ebf44","size":"930KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"954112","datemodified":"2021-01-14T07:46:26","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"56b8c822abc0b5d74be445dd09575879","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"b839c4a4d0d30f77a18e2958db4c06c1d0cb90bd","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1120be85411a4c4091bc1cad7f1e1af8","version":"38a828dcb5944a6f820916bfd8f83aa9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"9076370","datemodified":"2021-01-22T12:48:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/CP045149.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045149.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045149.scexe"],"md5sum":"c2a9a70688dabf26fda2a966af74bb16","name":"firmware-hca-mellanox-vpi-connectx4-1.0.10-1.1.x86_64.rpm","release":"2021-01-22T12:45:04","revision":"0","sha1sum":"717f8cb514aca52215881f6d147304ce4a94dcc6","size":"8MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.10"}],"id":{"product":"da6c398c130f48f9a5a32bd3c9213a90","version":"78848b4558d24304a5da6fe87a1d068d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64)for HPE Mellanox VPI(EthernetおよびInfinibandモード)ConnectX4デバイス - Linux x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16880059","datemodified":"2021-01-28T13:39:54","file_list":["/CP045689_BUILD_5.data","/CP045689.vmexe","/CP045689.vmexe64","/CP045689.vmfile","/CP045689_VMw.zip","/CP045689.xml","/payload.json","/CP045689_VMw.zip/index.xml","/CP045689_VMw.zip/vendor-index.xml","/CP045689_VMw.zip/metadata.zip","/CP045689_VMw.zip/vib20/CP045689/HPE_bootbank_CP045689_HPD8.5-7.0.0.15843807.vib","/CP045689_VMw.zip/metadata.zip/vendor-index.xml","/CP045689_VMw.zip/metadata.zip/vmware.xml","/CP045689_VMw.zip/metadata.zip/vibs/CP045689--5347455354483872335.xml","/CP045689_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045689_HPD8.5-7.0.0.15843807.xml"],"md5sum":"6629b8e610e0d5f49db160363db6bcd6","name":"CP045689.zip","release":"2021-01-28T13:37:04","revision":"0","sha1sum":"0c3061e4c61318d2add886b9ca11154e2a415dab","size":"16MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP045689","version":"HPD8.5-7.0.0.15843807"}]}],"id":{"product":"e4b6ca2c49674535912553cede176d16","version":"3b57be0361de4a4daf99b0ee70e63cd6"},"installation":{"command":"CP042626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:25:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:Â <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"125593","datemodified":"2021-01-08T22:10:28","file_list":["/cp042677.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-igbn-1.5.2.0.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vibs/igbn--38488993777072084.xml"],"md5sum":"392903c515cef277062e821c02ce9dd5","name":"cp042677.zip","release":"2021-01-08T22:09:04","revision":"0","sha1sum":"86de4401455fa23777d2a72172fb67eb097f1689","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"875c48447044433ba822fd2b79f25cb2","version":"2e44b0418d0c49cf909bbec08868dbf0"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where race condition during NIC adapter reset.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK, and MO3200JFFCL Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MO0400JFFCF、MO0800JFFCH、MO1600JFFCKおよびMO3200JFFCLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n <br />\n<strong>Release Version and/or Date:<br />\n      </strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n      </strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n     </strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n      </strong>None</p>\n\n<p><strong>Enhancements/New Features: </strong></p>\n\n<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"3200840","datemodified":"2020-12-11T13:10:48","file_list":["cp045596.xml","cpqsetup.exe","GP1635D9.rel","payload.json","setup.dll"],"md5sum":"8db7fe1cdef9a1f1d7bd07563e1b34df","name":"cp045596.exe","release":"2020-12-11T13:03:04","revision":"0","sha1sum":"1bcbc233d08470dec1f4609c335a50174e165579","size":"3MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"82cd9f1b504a4d3798c759e1d18439aa","version":"1726aa4798124e27907a018ff0dd21f4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:08:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD3"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD3"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD3"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD3"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD3"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD3"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5295651","datemodified":"2020-12-13T16:41:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/CP045487.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/TARM5ALLHPD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045487.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045487.scexe"],"md5sum":"6a5f97f8681a319156555f1e71e61f7c","name":"firmware-hdd-8fafc9efb2-HPD3-3.1.x86_64.rpm","release":"2020-12-13T16:28:05","revision":"0","sha1sum":"0e1c002152bd946d76fc1c9f03bc22d76627f18a","size":"5MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"9fd1abd8973f4c09aa450e541dc4ee41","version":"28838b27e63a4025af753343141d0d8d"},"installation":{"command":"CP041555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0111"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"13990340","datemodified":"2021-01-21T07:37:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/CP046459.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0111-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046459.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046459.scexe"],"md5sum":"3e6f2457bec8853b56263a531e3f8067","name":"firmware-d8000-0111-1.1.x86_64.rpm","release":"2021-01-21T07:27:04","revision":"0","sha1sum":"b44c4c865c732af177b34e0e38c15b1fa958b9fb","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0111"}],"id":{"product":"a2d50341a55d404a82473ce007636a93","version":"3d3a03bb29464a1085df4eadc4305dac"},"installation":{"command":"setup","command_params":"-t D8000 -v 0111 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff -l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"HPE D800012 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-16T04:52:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>In STD INQUIRY RESPONSE, the ErrM bit was always being set. The ErrM bit indicates that the enclosure firmware detects a mismatch in any of its package versions and the firmware version of a FRU component. The issue was due to an incorrect version of PSU firmware being included and that has been fixed.</p>\n\t</li>\n\t<li>\n\t<p>After installing the latest firmware on the enclosure I/O modules, the SES targets could not be discovered on the host. The virtual phy bit in SMP DISCOVER RESPONSE, which is used by the Microchip smartpqi HBA, was det for the virtual phy of the I/O module.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v183134/D8000_P20366-004.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Incorrect programming of the&nbsp;PHY ERROR COUNTERS parameter caused the amber LED to be lit, resulting in a false warning. The counter condition was corrected and the amber LED now functions correctly.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596357","datemodified":"2021-01-28T09:34:48","file_list":["payload.json","U33_2.42_01_23_2021.signed.flash","U33_2.42_01_23_2021.xml"],"md5sum":"7e3a33ca9ba994d70f51d244149671de","name":"U33_2.42_01_23_2021.fwpkg","release":"2021-01-28T09:26:10","revision":"0","sha1sum":"68f0c0257d0eb3976887f34195673a69079d83e4","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"972a94402aa14188aa7633893c7137b6","version":"98525e45652e462492bcb8d13717e82b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.42_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.42 (02/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33769688","datemodified":"2021-02-25T11:54:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/A46_2.42_02_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/CP046931.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.42_2021_02_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046931.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046931.scexe"],"md5sum":"26b75607e5776d1a9f149d8280c6992d","name":"firmware-system-a46-2.42_2021_02_23-1.1.x86_64.rpm","release":"2021-02-25T11:46:27","revision":"0","sha1sum":"4e4a571e79118aadc6f67ef7da47ede916bc374a","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"2.42_02-23-2021"}],"id":{"product":"871bd1fc79994166a0695e4fb3b5fd65","version":"db84dc1e7f2e4195af4b0d92decaa8db"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-22T17:11:46","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed an issue where the chassis name was not being reported for inventory control.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>System Programable Logic CPLD version 34<P><B>Problems Fixed:</B></P>Addressed an issue that could cause a slight degradation of performance.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5393092","datemodified":"2020-12-13T14:37:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/CP045454.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/SAVGNSD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045454.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045454.scexe"],"md5sum":"33302d90788c9838e3dc17b1df498a18","name":"firmware-hdd-fa46c607d6-HPD3-6.1.x86_64.rpm","release":"2020-12-13T14:25:04","revision":"0","sha1sum":"63d63258527a55d4ac6c3bb3cadba5653cb238ae","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"0","version":"HPD3"}],"id":{"product":"aedaa041caed4345872545de3f1efa40","version":"4909c3817b444532baa932e1fa19a095"},"installation":{"command":"CP040294.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1156528","datemodified":"2021-01-08T19:47:32","file_list":["cp045118.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt65x64.cat","ixt65x64.din","ixt65x64.inf","ixt65x64.sys","ixtmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXT.dll"],"md5sum":"2d7d282a390670a4cc16e8258037a2bf","name":"cp045118.exe","release":"2021-01-08T19:32:08","revision":"0","sha1sum":"eb2526c07712428a365019705918c69c0c5be028","size":"1MB","target_guids":[],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"a8417355844c4be0a58d7ebc978d6631","version":"2a4abf5d38e94e11958e9959e1668384"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixtドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product has been built with a new installer that prevents its installation on systems running Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"}],"sw_keys":[{"name":"ixt65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.8.7.</p>\n"}],"files":[{"bytes":"399685","datemodified":"2020-06-02T18:59:19","file_list":["/cp042680.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/ixgben-1.8.7-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/doc/README.txt","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/doc/release_note_ixgben_1.8.7-1OEM.670.0.0.8169922.txt","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/index.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/metadata.zip","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/vib20/ixgben/INT_bootbank_ixgben_1.8.7-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-ixgben-1.8.7.xml","/VMW-ESX-6.7.0-ixgben-1.8.7-15416643.zip/VMW-ESX-6.7.0-ixgben-1.8.7-offline_bundle-15416643.zip/metadata.zip/vibs/ixgben-8672713535151454730.xml"],"md5sum":"7ff1521f349b6e9ae88b2c839da6b0c1","name":"cp042680.zip","release":"2020-06-02T18:58:05","revision":"0","sha1sum":"6b69c377d4d16ed692746cc61f6e3345a8306ed4","size":"390KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"ixgben","version":"1.8.7-1OEM.670.0.0.8169922"}]}],"id":{"product":"ec0645c5197f4d97aa2ef8ed23e39857","version":"bf2e1b610304468b9d6dacd438eff39a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product corrects a recursion termination condition so that recursion correctly ends in the case of PCIe link down.<br />\nThis product addresses an issue where the ixgben driver has high CPU overhead when an SFP+ module is absent.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which notification from Link Partner when executed Link Flow Control settings.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.8.7-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD3"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JWFVNおよびMB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JWFVN and MB004000JWFVP Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16145892","datemodified":"2021-01-27T22:07:47","file_list":["/CP045630_BUILD_3.data","/CP045630.vmexe","/CP045630.vmexe64","/CP045630.vmfile","/CP045630_VMw.zip","/CP045630.xml","/payload.json","/CP045630_VMw.zip/index.xml","/CP045630_VMw.zip/vendor-index.xml","/CP045630_VMw.zip/metadata.zip","/CP045630_VMw.zip/vib20/CP045630/HPE_bootbank_CP045630_HPD3.3-7.0.0.15843807.vib","/CP045630_VMw.zip/metadata.zip/vendor-index.xml","/CP045630_VMw.zip/metadata.zip/vmware.xml","/CP045630_VMw.zip/metadata.zip/vibs/CP045630-4509834137048573394.xml","/CP045630_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045630_HPD3.3-7.0.0.15843807.xml"],"md5sum":"772f971aea0a1d33742b16ea59729877","name":"CP045630.zip","release":"2021-01-27T22:05:05","revision":"0","sha1sum":"5338ffea48af30b034103052f4f3081839680774","size":"15MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045630","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"640faf1092b548cf896ce4ae4d6b3ae8","version":"b7d1a92bbd6246049677ecdefb16b837"},"installation":{"command":"CP041752.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:34:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK  Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2795760","datemodified":"2020-12-16T13:26:54","file_list":["cp045290.xml","cpqsetup.exe","GP863aG3.rel","payload.json","setup.dll"],"md5sum":"66586b4ca22cbd7d2357c1f7fbaff273","name":"cp045290.exe","release":"2020-12-16T13:19:04","revision":"0","sha1sum":"3de458910fddd486f83fd6a6aa66da9096344209","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"539ed4e104fc49caac711d8c4da1d36a","version":"29037d244708467ba7fc7a4c7a71fdd6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-18T15:34:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1071344","datemodified":"2021-01-09T06:33:03","file_list":["cp045121.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"4cebfada97d5d9bca1a20d90d3483493","name":"cp045121.exe","release":"2021-01-09T06:17:05","revision":"0","sha1sum":"74bccb2117f2c5659bb7d1959a2bef7de6535886","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"0","version":"12.18.11.1"}],"id":{"product":"87793aff72a54849a327ce026784372d","version":"125af99799fb48db8f70422ef44fa0f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n\n<p>This product add Wrapping and fix Support To Cometlake,and added thermal sensor support for fiber NIC.</p>\n","latest_fixes_x_late":"<p>This product correct an issue which override and copy constructor to MSIX_AFFINITY_MANAGEMENT class to eliminate KW issues with double freeing memory.<br />\nThis product correct an issue which fixed e1r compile to exclude Nahum Icelake defines.<br />\nThis product correct an issue which fixed conversion of timestamp into 64bit value.<br />\nThis product correct an issue which fix for NDIS Miniport Kernel Pointer Leakage</p>\n"},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"e1r68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16497103","datemodified":"2021-01-28T17:41:47","file_list":["/CP045701_BUILD_20.data","/CP045701.vmexe","/CP045701.vmexe64","/CP045701.vmfile","/CP045701_VMw.zip","/CP045701.xml","/payload.json","/CP045701_VMw.zip/index.xml","/CP045701_VMw.zip/vendor-index.xml","/CP045701_VMw.zip/metadata.zip","/CP045701_VMw.zip/vib20/CP045701/HPE_bootbank_CP045701_HPD9.20-7.0.0.15843807.vib","/CP045701_VMw.zip/metadata.zip/vendor-index.xml","/CP045701_VMw.zip/metadata.zip/vmware.xml","/CP045701_VMw.zip/metadata.zip/vibs/CP045701-3750303068024258151.xml","/CP045701_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045701_HPD9.20-7.0.0.15843807.xml"],"md5sum":"a16eb08bb3ba371ec040ad604fb45b12","name":"CP045701.zip","release":"2021-01-28T17:39:04","revision":"0","sha1sum":"aadfc83d6bff7681e9e12553d0e5bf9e2fde5af6","size":"15MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP045701","version":"HPD9.20-7.0.0.15843807"}]}],"id":{"product":"6b5a27285d114b399ac0db53bb209710","version":"aa3d4406089f4e5187d48f412bb46bab"},"installation":{"command":"CP042219.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:34:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10+ controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2700683","datemodified":"2021-02-02T11:21:14","file_list":["./opt/hpe/storcli/storcli64","./usr/lib/.build-id","./usr/lib/.build-id/18","./usr/lib/.build-id/18/da821f3768420ff26e9e349668617a13970af6","./usr/share/smartupdate/storcli/component.xml"],"md5sum":"4b711c3402767b7a8fc0810e471b5241","name":"storcli-007.1616.0000.0000-1.x86_64.rpm","release":"2021-02-02T11:18:04","revision":"0","sha1sum":"00ba6ca4c927842ff26872c8ddace50ef86803e0","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"type_of_change":"0","version":"007.1616.0000.0000"}],"id":{"product":"1e5bf302dfcf48eb8cdaa03a5c140f4d","version":"9e38448dcc1345188b95e240d1dad709"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li>\n\t<li>To install the StorCLI RPM, run the rpm -ivh &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li>\n\t<li>To upgrade the StorCLI RPM, run the rpm -Uvh &lt;StorCLI-x.xx-x.noarch.rpm&gt; command</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/hpe/storcli and the executable name is storcli64.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-28T08:49:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This version of StorCLI supports maintaining, troubleshooting, and configuration functions for the MegaRAID&reg; Gen10+ controller products: MR416i-a,&nbsp;MR416i-p,&nbsp;MR216i-a,&nbsp;MR216i-p</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"storcli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1940528","datemodified":"2021-02-09T08:32:51","file_list":["cp045132.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"35015e8a88781c5dea915aeca4f8e5a3","name":"cp045132.exe","release":"2021-02-09T08:18:04","revision":"0","sha1sum":"5ece9a15cf8ffa962f51dfa57d073597710ebf6a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"6d1e58e8f89340958bf7818046e9b7c7","version":"7f3bfdf771f04b0cb90078507a9e361c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ol>\n\t<li>The number of VMs is limited to 124 VMs with VMQ(Virtual Machine Queue) mode.</li>\n\t<li>The driver supports up to 200 vPorts in ConnectX-4 Lx and 254 vPorts in ConnectX-5 with SRIOV(Single Root I/O Virtualization).</li>\n</ol>\n","latest_fixes_x_late":"<ol>\n\t<li>This product correct an issue which caused memory corruption in case the OS provided continues memory across multiple pages that did not start with offset zero on aligned memory address.</li>\n\t<li>This product correct an issue that prevented the device from being updated with the new driver because the driver was already in the driver store.</li>\n\t<li>This product correct an issue which occasionally prevented the VF counters from being displayed correctly in perfmon.</li>\n\t<li>This product correct an issue which caused the driver to report zero link speeds supported when working with firmware older than 1x.18.0240.</li>\n\t<li>This product correct an issue which fixed a memory leak issue in error flow during driver initialization.</li>\n</ol>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"364786","datemodified":"2021-01-14T06:16:23","file_list":["/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip","/cp045074.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vibs/bnxtroce--6521842855526875576.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/vibs/bnxtnet--8154265287820674143.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922-offline_bundle-17341386.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.670.0.0.8169922.xml"],"md5sum":"9d6a615cb7894e2abadf37f91e7a3aa7","name":"cp045074.zip","release":"2021-01-14T06:15:04","revision":"0","sha1sum":"006f3f62ab73f953570e0d22f68fb7661fa8fbfa","size":"356KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtroce","version":"218.0.16.0-1OEM.670.0.0.8169922"},{"name":"bnxtnet","version":"218.0.38.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"8cec45e9870e4e5fad3d7d2b3b545e8d","version":"3555fcf212c94841b362d82dc76d07fb"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where RDMA Ethernet Controller error description on ESXi Host.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2019用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"906528","datemodified":"2020-06-12T10:45:28","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044562.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"49c6fa5346af463c999d04a805a12340","name":"cp044562.exe","release":"2020-06-12T10:32:05","revision":"0","sha1sum":"ace4876a411ff30399c36a4f9bb4bb25e919a870","size":"885KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"14ccfdf7a8d64255bce75290d1e21746","version":"299f3ac601a4460d9602ffd6fac4d9d8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None&nbsp;</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5913317","datemodified":"2020-12-13T12:54:01","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/CP045423.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045423.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045423.scexe"],"md5sum":"31098f76edb415ebdc34a60549d31b32","name":"firmware-hdd-10385ef3e6-HPD2-5.1.x86_64.rpm","release":"2020-12-13T12:42:04","revision":"0","sha1sum":"0a192933216d307c2e4fb9be8aa0d2b45ad9dd7c","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"1d54c8dcf99741aabe78b8a4e54d84f8","version":"4f1e07ee21c24ee7a1ac76cc9e675edd"},"installation":{"command":"CP041452.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MM1000GFJTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します： MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5397805","datemodified":"2020-12-13T14:35:51","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/CP045453.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/SAVGNTG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045453.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045453.scexe"],"md5sum":"dba1ca565929feed6e69174cade10fc5","name":"firmware-hdd-95af9a555e-HPG5-5.1.x86_64.rpm","release":"2020-12-13T14:24:05","revision":"0","sha1sum":"a9f7ec44978769e1eb7a6b28410ea0dcf8d77910","size":"5MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"e8a7c3696813408f916249b859b6b722","version":"ecb8ee670295494cb722ea656f653406"},"installation":{"command":"CP040344.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100859","datemodified":"2021-01-14T07:19:25","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"2af0f156d813885ad60dd90dbf3c0913","name":"kmod-be2net-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"a66b7aaddc230597c9153aa9221b1e7d40eb1c2e","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100863","datemodified":"2021-01-14T07:23:05","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"8d03323d34aff4826670cd28a059346e","name":"kmod-be2net-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"b9b8b6aeae0d006d85e816f05b9b69556bdbde31","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"47f79ff4032545a7bdbbbdab76c5b9b2","version":"d975e0a231f5496c80ea72988a8242ca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5447701","datemodified":"2020-12-13T14:36:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/CP045451.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/SAVGRTG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045451.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045451.scexe"],"md5sum":"30bf2ebd3825700d3abd3cf53df441b5","name":"firmware-hdd-ec908c3650-HPG8-7.1.x86_64.rpm","release":"2020-12-13T14:23:12","revision":"0","sha1sum":"dba8cc089d2a9ed5f2589b2e57da0e403274a41c","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"38437d438933420e8063d6e963ffd91f","version":"72c7c8eb16f24655bcf3be7b1a2a977e"},"installation":{"command":"CP040273.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel NICs Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3396047","datemodified":"2021-01-09T01:56:43","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-igb","./lib/modules/5.3.18-22-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"a145adaddde307e5b02ae3aae65a4165","name":"hp-igb-kmp-default-6.2.5_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-09T01:35:04","revision":"0","sha1sum":"d47aeb631b42f59d13aa4cc70053b0d6da5659a3","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.2.5-1"},{"bytes":"2898917","datemodified":"2021-01-09T01:44:45","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-igb","./lib/modules/4.12.14-195-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"d8f03b38e3c83ef2a1bbf159f24dc06f","name":"hp-igb-kmp-default-6.2.5_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-09T01:35:04","revision":"0","sha1sum":"e84d40240c3ec80e48813342aec6370ba650602f","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.2.5-1"}],"id":{"product":"a162b7594d8d4a02bf2f3f7d9fe2609d","version":"76dd221b4c0d4ed3b0a4ebdd25e5fc48"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel igbドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</li>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 ProLiant Gen9 NVMe 儲存背板上的韌體。"},{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes."},{"lang":"ko","x_late":"이 구성 요소는 ProLiant Gen9 NVMe 스토리지 백플레인에서 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新 ProLiant Gen9 NVMe 存储背板上的固件。"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"410377","datemodified":"2018-10-03T00:03:54","file_list":["./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/.setup","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/CP034973.xml","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/NVMe_BP_flashV8B4_signed.hex","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-nvmebackplane-8.4-4.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP034973.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP034973.scexe"],"md5sum":"a3447375df9de5db8adb2f006b8883e3","name":"firmware-nvmebackplane-8.4-4.1.i386.rpm","release":"2018-10-03T05:03:03","revision":"0","sha1sum":"2b62a77cdc4235f4498672d0584c099cdb207168","size":"400KB","target_guids":[],"type_of_change":"0","version":"8.4"}],"id":{"product":"591f92a69b8e4f239251cc96e1b31290","version":"8ff6481f2f5e4e97804bc6514d03a4ab"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/i386-linux-gnu&#39; location</li>\n\t<li>The CP034973.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-nvmepic-gen9-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP034973.scexe in the &#39;/usr/lib/i386-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/i386-linux-gnu/firmware-nvmepic-gen9-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/i386-linux-gnu/firmware-nvmepic-gen9-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-nvmepic-gen9-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory,&nbsp;/SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上更新元件 - NVMe 背板 PIC 韌體"},{"lang":"en","x_late":"Online Flash Component for Linux - NVMe Backplane PIC Firmware"},{"lang":"ko","x_late":"Linux용 온라인 ROM 플래시 구성 요소 - NVMe 백플레인 PIC 펌웨어"},{"lang":"cn","x_late":"Linux版在线刷新组件 - NVMe背板PIC固件"},{"lang":"ja","x_late":"Linux用オンラインフラッシュコンポーネント - NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-15T08:46:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<strong>Note:</strong> If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (C).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"73960","datemodified":"2021-02-09T13:51:24","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/smartpqi","./lib/modules/4.18.0-240.el8.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"2e0df93222dd8368c5d8092d2d814673","name":"kmod-smartpqi-2.1.8-040.rhel8u3.x86_64.rpm","release":"2021-02-09T13:45:04","revision":"0","sha1sum":"d217c6ae6460dab1f6b586112ac3e5b420939dc6","size":"72KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.8-040"},{"bytes":"73892","datemodified":"2021-02-09T13:50:08","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/smartpqi","./lib/modules/4.18.0-193.el8.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"8e6bbac31a4787387991f715ba371588","name":"kmod-smartpqi-2.1.8-040.rhel8u2.x86_64.rpm","release":"2021-02-09T13:45:04","revision":"0","sha1sum":"325c81d76398b872825b8c86e9f359e2a65846e7","size":"72KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.8-040"}],"id":{"product":"d952c2a30d6f4bb29ccf7ec141400337","version":"c00af0d9c31341d298ad4120812fbc8a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-&lt;version&gt;.rhel8&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel8&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-<version>.rhel8<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-<version>.rhel8<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 8 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-04T12:00:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>To add&nbsp;an enhancement to fix the stale Drive fi&nbsp;rm&nbsp;ware version returned by a Power Shell command.&nbsp;</p>\n","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This release provides the following fixes:&nbsp;</p>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the system hangs when resuming from hibernation.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue&nbsp;where the enclosure identifier field corresponding to the physical devices became empty in&nbsp;lsscsi/sysfs&nbsp;during device rescan.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue to display topology using PHY numbers&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver did not export valid SAS&nbsp;initiator_port_protocols&nbsp;and&nbsp;target_port_protocols&nbsp;to&nbsp;sysfs.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver would cause a kernel panic if it got an invalid response from the controller.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the LUN reset, system shutdown, system suspend, system hibernate, controller offline, and I/O requests could reach the controller when they are not required.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where after modifying the logical volume size,&nbsp;lsblk&nbsp;command still shows up previous size of logical volume.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where during the device discovery, the driver issued an INQUIRY to physical devices, and these requests could get lost due to broken devices, loss of signal issues, etc. This would cause device discovery to get hung.&nbsp;</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>-</p>\n","curr_fixes_x_late":"<p>-</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"lang":"ja","x_late":"このコンポーネントは、NVMeドライブをイジェクトする際の致命的なマスク不可割り込み (NMI) を修正するためにレジストリの変更をインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"614648","datemodified":"2018-10-04T14:27:54","file_list":["cp034635.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"md5sum":"f68b264facf5dc7bda6544f68d68cbf0","name":"cp034635.exe","release":"2018-10-17T00:00:00","revision":"2","sha1sum":"4890b498e51bfeb486bd2a298d4a977f7ab2a37d","size":"600KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"type_of_change":"0","version":"1.1.0.0"}],"id":{"product":"130da7feaa1d444b8b70a759892883b1","version":"58748ca220fa40e58bc0bdba72e5a867"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Windows"},{"lang":"ja","x_late":"Windows用NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"2020","subdev":"00EA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-2020159000ea","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-12-20T23:04:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n\t<li>Added support for the HPE ProLiant XL270d Gen10 and the HPE ProLiant XL420 Gen10</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"nvmeejectfix5.dll","sw_key_expectedpath":"%ProgramFiles%\\nvmefix"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"cn","x_late":"驱动程序 - 视频"},{"lang":"ja","x_late":"ドライバ - ビデオ"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eH3ビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"1602904","datemodified":"2019-09-26T01:36:18","file_list":["cp040214.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO.inf","mxg2hdo64.cat","MxG2hDO64.sys"],"md5sum":"a23b617933f3f75034a1335e417cbe56","name":"cp040214.exe","release":"2019-09-26T01:35:02","revision":"0","sha1sum":"e929af0107836f3a091ad73b4996ab59062572be","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"67cd5bd58926486d97948e2f92725c2f","version":"c8c30aaf491f47ab82361327e2d3c78e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Matrox G200eH3 Video Controller Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"Windows Server 2012 R2用Matrox G200eH3ビデオコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0538","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-0538159000e4","type":"pci","ven":"102B"},{"dev":"0538","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-05381590027f","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix for random screen corruption when changing resolution that could occur with driver versions 9.15.1.184 and 9.15.1.218.</li>\n\t<li>Fix for a display freeze that could occur when running the Windows Display Diagnostics tool (dispdiag.exe).</li>\n</ul>\n"},{"curr_enhancements_x_late":"Add support for iLO 5 version 2.x firmware.\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn and ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixnおよびixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"961336","datemodified":"2021-02-01T06:42:48","file_list":["cp045153.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"a4433b94eae50802d431e6450eeed01b","name":"cp045153.exe","release":"2021-02-01T06:26:04","revision":"0","sha1sum":"951b7adc8ac79f75b7fb20e692ef4ee73324cc4e","size":"938KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"8580226958cf4ea0a4c511ccdfa9e081","version":"2062eb0e8cbd4f7c9d5317075deb73d5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"Smart Storage Administrator CLI (智慧型儲存管理員 CLI (SSACLI) 是一款基於命令列的磁碟組態程式，可用於設定、管理、診斷及監控 Smart Array 控制器，以及現在的主機匯流排介面卡 (HBA)、儲存控制器等其他儲存裝置和 SCSI Express 磁碟機、SAS 交換器裝置等將來的裝置。"},{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."},{"lang":"ko","x_late":"스마트 스토리지 관리자 CLI(SSACLI)는 명령줄 기반의 디스크 구성 프로그램으로 스마트 어레이 컨트롤러와 호스트 버스 어댑터(HBAs)와 같은 기타 저장 장치, 스토리지 컨트롤러, SCSI Express 드라이버와 같은 미래 장치 및 SAS 스위치 장치를 구성, 관리, 진단 및 감시합니다."},{"lang":"cn","x_late":"Smart Storage Administrator CLI (SSACLI)是一款基于命令行的磁盘配置程序，可帮助您配置、管理、诊断和监控智能阵列控制器，且现在还可支持其他存储设备，如主机总线适配器（HBA）、存储控制器，未来还可支持 SCSI Express 驱动器以及 SAS 交换机设备。"},{"lang":"ja","x_late":"Smart Storage Administrator CLI(SSACLI) は、Smartアレイコントローラーや他のストレージデバイス、例えばホストバスアダプター(HBA)、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるコマンドラインベースのディスク構成プログラムです。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p>\n\n<p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p>\n\n<p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"8463848","datemodified":"2021-02-15T15:57:37","file_list":["cp041183.xml","cpqsetup.exe","genericmsi.dll","SSACLI510440_X64.msi"],"md5sum":"55bca52f472dc98e56d837e10f99da42","name":"cp041183.exe","release":"2021-02-15T15:54:09","revision":"0","sha1sum":"eaf4925dc986cfe5134c579fc429917cefa40420","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"type_of_change":"0","version":"5.10.44.0"}],"id":{"product":"01e0939311154208bbd5b8d9e5157a9c","version":"75651141a48843bea4537056071992e6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support to the HPE SR Gen10 Plus Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5164166","datemodified":"2020-12-13T16:12:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/CP045474.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/PLTGIID7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045474.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045474.scexe"],"md5sum":"9b42c22d2bb0dfef982868fc12fcee07","name":"firmware-hdd-481c8ea9a7-HPD7-3.1.x86_64.rpm","release":"2020-12-13T16:01:21","revision":"0","sha1sum":"54820997190ed5850a4207cf36a5b240dd92e371","size":"4MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"189399e2f82a48ee85c54d779b410263","version":"f976d4260542472c86ccf6b4e013f6fd"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) -  EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:20:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1468862","datemodified":"2020-11-04T08:17:10","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp044769.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"8e60408dd9bcb10ff3820eb2e7b7f680","name":"cp044769.zip","release":"2020-11-04T08:16:18","revision":"0","sha1sum":"debd7fca0dd97d57fd961a63e36f03cc472c85ee","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"1b944a04f5844e8cab35edaa8a7e8e54","version":"00648c3c2a5d4ab59551b9fbae5baf38"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:01:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.6.182.2</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>One port of an Fibre Channel adapter could not complete to reconnect to storage after storage upgrade if the host system had been online for over 3 months</li>\n\t<li>Turning on 3PAR Persistent Checksum after the host operating system was running would not result in Persistent Checksum being enabled between the adapter and 3PAR array.</li>\n\t<li>Virtual Machines (VMs) could not access certain storage arrays when those arrays were attached to the VM using N-Port ID Virtualization (NPIV)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"101922","datemodified":"2019-12-20T07:01:42","file_list":["/cp042807.xml","/Release_Notes_lsi-mr3-7.706.09.00-1OEM.txt","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/vendor-index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/vib20/lsi-mr3/Avago_bootbank_lsi-mr3_7.706.09.00-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vibs/lsi-mr3--1465933317.xml"],"md5sum":"317a52ca94781ab4a74603cee2d7fb76","name":"cp042807.zip","release":"2019-12-20T07:00:04","revision":"0","sha1sum":"74ce4b13adb8ce3349eecb65788ba7cbf062d31a","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"0","version":"2019.12.13","vib_list":[{"name":"lsi-mr3","version":"7.706.09.00-1OEM.670.0.0.8169922"}]}],"id":{"product":"d348cc79cad0401481d553a1970ba39e","version":"50f027b03ab249ef9a76185694d24e43"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller (64-bit) Driver for vSphere 6.7 (Driver Component)"},{"lang":"ja","x_late":"vSphere 6.7用HPE SmartアレイP824i-p MRコントローラー（64ビット）ドライバー（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-13T10:42:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added VMware vSphere 6.7 OS support</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Addressed a vSAN Fault Tolerance test failure seen in JBOD mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-mr3:7.706.09.00-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWBHR"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWBHR&nbsp;Drive<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4857815","datemodified":"2020-12-13T08:07:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/CP045376.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/T14SEnD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045376.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045376.scexe"],"md5sum":"2e79ffc2f9f64d9ccf7cfdd0ca89cc10","name":"firmware-hdd-2e4c61fc63-HPD4-5.1.x86_64.rpm","release":"2020-12-13T07:55:10","revision":"0","sha1sum":"80928330bc155dc9a9666042f42de6c4a0ea7aaf","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"57c8ff295b854dbeaea4e204fed3ef83","version":"e1f76f75c3eb4c3686fe0db805a0f534"},"installation":{"command":"CP040299.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWBHR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:28:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP1."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"99227","datemodified":"2019-09-16T13:58:05","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio/component.xml"],"md5sum":"1f60ba6dae43e15aab3ff866e4728731","name":"iscsiuio-2.11.5.13-3.sles15sp1.x86_64.rpm","release":"2019-09-16T13:57:02","revision":"0","sha1sum":"c15177e3324160636535c6a31a5e6c0260b0a121","size":"96KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec563dc806"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"d1b3d5a922ad44aab83b4058affcf027","version":"d4fecb6ed31c479a92efb8940576786e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP1"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-10-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iscsiuio","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2907922","datemodified":"2021-01-09T00:09:26","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-igb","./lib/modules/4.12.14-120-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"99e2d9e75c6fbc73af03c8e1780e08a8","name":"hp-igb-kmp-default-6.2.5_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-08T23:53:05","revision":"0","sha1sum":"0a59bbc528c00059842ed3cf17c1f956d0c99ffa","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.2.5-1"},{"bytes":"2811870","datemodified":"2021-01-09T00:18:20","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-igb","./lib/modules/4.12.14-94.41-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"f12c58ffdcb60cdfdc12f46d1d0f6ba4","name":"hp-igb-kmp-default-6.2.5_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-08T23:53:05","revision":"0","sha1sum":"8464fc516dc388f4e7276525fd83e2009cd76d5a","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"0","version":"6.2.5-1"}],"id":{"product":"5049ff108a414cae906f3f80d242a819","version":"f7db2aa288e645bf974ed0c5455328b2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驱动程序 "},{"lang":"ja","x_late":"HPE Intel igbドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<p>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"為 iLO 提供 OS 層級無代理程式管理資訊與使用中狀況系統 (Active Health System) 事件。"},{"lang":"en","x_late":"Provides iLO with OS-level Agentless Management information and Active Health System events."},{"lang":"ko","x_late":"iLO에 OS 레벨 Agentless 관리 정보 및 Active Health System 이벤트를 제공합니다."},{"lang":"cn","x_late":"向 iLO 提供操作系统级无代理管理信息和活动健康系统事件。"},{"lang":"ja","x_late":"iLOにOSレベルのエージェントレスマネジメントの情報およびアクティブヘルスシステムイベントを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<ul>\n\t<li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li>\n\t<li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li>\n\t<li>The controller&nbsp;HP StorageWorks 81B 8Gb Single Port PCI-e FC HBA will be shown as&nbsp;QLogic BR-415/815 4G/8G FC HBA.</li>\n</ul>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li>\n\t<li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li>\n\t<li>コントローラーHP StorageWorks 81B 8Gb シングルポートPCI-e FC HBAは QLogic BR-415/815 4G/8G FC HBAと表示されます。</li>\n</ul>\n"}],"files":[{"bytes":"8508080","datemodified":"2021-02-18T07:22:24","file_list":["cp046273.xml","cpqsetup.exe","hpqams.cab","hpqams.msi","install.xml","MergeModule2012.msi","multisetup.dll"],"md5sum":"183b9793affdfe3f36042430d86647f8","name":"cp046273.exe","release":"2021-02-18T07:20:06","revision":"0","sha1sum":"06005a9039e4db7139df6b0ced2b96029de6861b","size":"8MB","target_guids":[],"type_of_change":"0","version":"10.99.0.0"}],"id":{"product":"634c75df063f418e8a220d306623aa90","version":"eebc6dba482942fab422c7e1d787cd5d"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"<P>將智慧型元件放在臨時目錄中，按兩下執行。</P>\n<P>選擇「Install (安裝)」開始解壓縮至硬碟上的一個臨時位置。</P>\n<P>按一下「Install (安裝)」繼續進行驅動程式的安裝。</P>"},{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the service installation.</P>"},{"lang":"ko","x_late":"<P>스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.</P>\n<P>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.</P>\n<P>\"설치\" 버튼을 클릭하여 서비스 설치 작업을 시작합니다.</P>"},{"lang":"cn","x_late":"<P>将智能组件置于临时目录中，然后双击运行。</P>\n<P>选择“安装”，开始提取至硬盘的临时位置。</P>\n<P>点击“安装”按钮执行服务安装。</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>[インストール]ボタンをクリックしてサービスインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for HPE Apollo, ProLiant and Synergy Gen9 servers"},{"lang":"ja","x_late":"HPE Apollo、ProLiantおよびSynergy Gen9サーバーのHPE ProLiant Agentless Managementサービス"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-17T07:07:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>None</p>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed the unexpected SNMP Trap 11020 being generated even if there is no change in health status. The issue was caused by SNMP cpqHoMibHealthStatusArray OID value being OK (2)&nbsp;even if the corresponding hardware is not present. The default condition has been changed to Unknown (0).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Logical Drive Trap&nbsp;5023.</li>\n\t<li>Changed IDE/SATA interval time from 120 seconds to 60 seconds.</li>\n\t<li>Redirect more iLO security logs to the Windows event system.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed IML missing NIC link down record if the user unplugs many cables at the same time.</li>\n\t<li>Fixed iLO web GUI missing IPv6 address when Windows Hype-V switch is created.</li>\n\t<li>Fixed a crash issue when AMS is querying iSCSI information.</li>\n\t<li>Fixed incorrect drive status if IDE SATA drive is busy on access.</li>\n\t<li>Fixed incorrect drive status if Windows see&nbsp;the predictive failure drive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"}],"sw_keys":[{"name":"hpqams.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\AMS\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17621130","datemodified":"2021-01-28T15:11:51","file_list":["/CP045695_BUILD_4.data","/CP045695.vmexe","/CP045695.vmexe64","/CP045695.vmfile","/CP045695_VMw.zip","/CP045695.xml","/payload.json","/CP045695_VMw.zip/index.xml","/CP045695_VMw.zip/vendor-index.xml","/CP045695_VMw.zip/metadata.zip","/CP045695_VMw.zip/vib20/CP045695/HPE_bootbank_CP045695_HPG2.4-7.0.0.15843807.vib","/CP045695_VMw.zip/metadata.zip/vendor-index.xml","/CP045695_VMw.zip/metadata.zip/vmware.xml","/CP045695_VMw.zip/metadata.zip/vibs/CP045695-9180564223706490456.xml","/CP045695_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045695_HPG2.4-7.0.0.15843807.xml"],"md5sum":"52e3cc440bb0ee55033464854352e574","name":"CP045695.zip","release":"2021-01-28T15:08:04","revision":"0","sha1sum":"4b7b6f9437ffff4df8f86365bbcb05d208a5e82e","size":"16MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045695","version":"HPG2.4-7.0.0.15843807"}]}],"id":{"product":"fbe68804b30c4fe28e13ea472cae5392","version":"3536f51b94174d6e9930653ae72c79e2"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:30:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。\nerrataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。  だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。  そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>-</p>\n"}],"files":[{"bytes":"70156","datemodified":"2021-02-09T13:38:19","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"ffea4b16190e839e9dc17130c4967685","name":"smartpqi-kmp-default-2.1.8-040.sles12sp5.x86_64.rpm","release":"2021-02-09T13:32:05","revision":"0","sha1sum":"2cb9b506d067e02fdd5e2b28ed687282b0eed6c6","size":"68KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.8-040"},{"bytes":"71619","datemodified":"2021-02-09T13:37:05","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"7555fd7c996fae99e5ea3633febfe6b4","name":"smartpqi-kmp-default-2.1.8-040.sles12sp4.x86_64.rpm","release":"2021-02-09T13:32:05","revision":"0","sha1sum":"7d114604adc49c8cd8e3e699d08f46a99182059a","size":"69KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.8-040"}],"id":{"product":"9225c9596a464443833dcfea70680689","version":"1654d15cf3794a0da4d353bbf31cb3a5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh smartpqi-kmp-default-&lt;version&gt;.sles12&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles12&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh smartpqi-kmp-default-<version>.sles12<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e smartpqi-kmp-default-<version>.sles12<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 12 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"},{"id":"ven_0x1590&dev_0x02db","target_guid":"","type":"pcie"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">To add an enhancement to fix the stale Drive fi&nbsp;rm&nbsp;ware version returned by a Power Shell command.&nbsp;</p>\n","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This release provides the following fixes:&nbsp;</p>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the system hangs when resuming from hibernation.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue&nbsp;where the enclosure identifier field corresponding to the physical devices became empty in&nbsp;lsscsi/sysfs&nbsp;during device rescan.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue to display topology using PHY numbers&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver did not export valid SAS&nbsp;initiator_port_protocols&nbsp;and&nbsp;target_port_protocols&nbsp;to&nbsp;sysfs.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver would cause a kernel panic if it got an invalid response from the controller.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the LUN reset, system shutdown, system suspend, system hibernate, controller offline, and I/O requests could reach the controller when they are not required.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where after modifying the logical volume size,&nbsp;lsblk&nbsp;command still shows up previous size of logical volume.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where during the device discovery, the driver issued an INQUIRY to physical devices, and these requests could get lost due to broken devices, loss of signal issues, etc. This would cause device discovery to get hung.&nbsp;</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>-</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5764205","datemodified":"2021-01-28T08:48:20","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"4eeab51ac22d21762fdcefbdc8745732","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u8.x86_64.rpm","release":"2021-01-28T08:30:07","revision":"0","sha1sum":"b692fa1164a7e33ccdc7625450c8122745ac4ed9","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"c54f04999d6b49af842950ebb0be7aac","version":"cefbb324378a48a49f2337e06ec3b0cf"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;driver version&nbsp;to 10.01.00.64.07.6-k1a</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ol>\n\t<li>Multipath&nbsp;message appears with storage port reset, node reboot and panic</li>\n\t<li>Port login&nbsp;does not complete&nbsp;with storage port reset activity</li>\n\t<li>Multipath command does not respond</li>\n\t<li>Fix SCSI error-handling when I/O completes after an abort completion which may cause system to terminate unexpectedly</li>\n\t<li>Please refer advisory at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ol>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000JWDFD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue during unaligned write commands, only found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5936058","datemodified":"2020-12-13T12:50:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/CP045420.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/HLEAHssseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045420.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045420.scexe"],"md5sum":"3e5470b09dba679da348c39f705d851d","name":"firmware-hdd-aaf1014ede-HPD2-6.1.x86_64.rpm","release":"2020-12-13T12:36:12","revision":"0","sha1sum":"11a45f886ebe4963a0f118e39ac70fb40af8a825","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"2","version":"HPD2"}],"id":{"product":"421cc08cc7bc4143866089180c719d3f","version":"6471977c9a6a40999b5407e11fd0d7aa"},"installation":{"command":"CP040338.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, only found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, only found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0600JDYTN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read. </li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>      </strong>None.</p>"}],"files":[{"bytes":"3661840","datemodified":"2020-12-17T10:44:40","file_list":["cp045510.xml","cpqsetup.exe","HKFL4CD7.rel","payload.json","setup.dll"],"md5sum":"68ed1f74c0a29a9e4c0bfabc50ea45cf","name":"cp045510.exe","release":"2020-12-17T10:35:09","revision":"0","sha1sum":"e1591cb9c975042e67385a00f0f28ba99023e526","size":"3MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"68a7de4833704c8fb3dbc75f2b162b30","version":"55bfe42d61be4ff9bf45287ae39cabf4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:35:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read. </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL, and EG0900FCSPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"2889296","datemodified":"2020-12-17T13:28:08","file_list":["cp045495.xml","cpqsetup.exe","payload.json","setup.dll","TA13SED2.REL"],"md5sum":"a154f9af6ac98d7f0c390d90773c5b72","name":"cp045495.exe","release":"2020-12-17T13:19:08","revision":"0","sha1sum":"f9c07ce7f0291853e49a6f7c596a440777ad69da","size":"2MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"e3b32b83ce544644bc4408de465e0c11","version":"32b6aca4a6ce47e9b8effff556a7ce0f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:30:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for ESXi 7.0 U1.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16417352","datemodified":"2021-01-28T12:22:00","file_list":["/CP045948_BUILD_5.data","/CP045948.vmexe","/CP045948.vmexe64","/CP045948.vmfile","/CP045948_VMw.zip","/CP045948.xml","/payload.json","/CP045948_VMw.zip/index.xml","/CP045948_VMw.zip/vendor-index.xml","/CP045948_VMw.zip/metadata.zip","/CP045948_VMw.zip/vib20/CP045948/HPE_bootbank_CP045948_HPG6.5-7.0.0.15843807.vib","/CP045948_VMw.zip/metadata.zip/vendor-index.xml","/CP045948_VMw.zip/metadata.zip/vmware.xml","/CP045948_VMw.zip/metadata.zip/vibs/CP045948-63575065950295798.xml","/CP045948_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045948_HPG6.5-7.0.0.15843807.xml"],"md5sum":"80e38c63d801d839a9bd0beaf6cd28b0","name":"CP045948.zip","release":"2021-01-28T12:19:04","revision":"0","sha1sum":"b177a7c96d5965b8ff19804cf7e1a77fc900099e","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045948","version":"HPG6.5-7.0.0.15843807"}]}],"id":{"product":"c5274a8d3e3e40d790c226da85bd84aa","version":"e1ae5aaa79814754900e177669078eb8"},"installation":{"command":"CP040790.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-23T09:06:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>HPG6 introduces bug fixes, reliability enhancement and modification in SMART Attributes. Once HPG6 is downloaded, the drive cannot be changed back to an earlier firmware (eg, HPG3).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for ESXi 7.0 U1.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3247728","datemodified":"2020-12-11T11:55:09","file_list":["cp044648.xml","cpqsetup.exe","G1633LD8.rel","payload.json","setup.dll"],"md5sum":"409e763558fb8004166105ecb2717961","name":"cp044648.exe","release":"2020-12-11T11:46:11","revision":"0","sha1sum":"1ed076d6c2b6c28eea810974ca990e2bcaffd3f7","size":"3MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"38d33d1fd49e4ce68d34a95d7c8c3f1f","version":"f0031a55060a411fbf9333210e77eaa0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-23T14:14:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.77"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.77"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux platforms."},{"lang":"ja","x_late":"このパッケージには、Linux プラットフォームで動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.77 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.15.80</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.8.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3148378","datemodified":"2021-03-09T03:57:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/CP045081.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/CP045081.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/nic_fw/hp_mbi_7.18.77.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.2.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045081.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045081.scexe"],"md5sum":"6ca72e3262381b299d8ce4f09176b28d","name":"firmware-nic-qlogic-nx2-bl-1.2.3-1.1.x86_64.rpm","release":"2021-03-09T03:49:21","revision":"0","sha1sum":"f6e8d4b7b6dca23deae9e6b094c297df41e351a7","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.2.3"}],"id":{"product":"0b1755ac9ea74055988f525407cd9d18","version":"d55720a0a7e04e859b2c681399c3f7a9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP045081.txt file.The results of the firmware upgrade are saved&nbsp;in CP045081.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティfor Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n\n<p>&nbsp;</p>\n\n<p>This product now supports the following operatings systems:</p>\n\n<ul>\n\t<li>Red Hat Enterprise Linux 7 Update 7</li>\n\t<li>Red Hat Enterprise Linux 8 Update 0</li>\n\t<li>SUSE Linux Enterprise Server 15 SP1</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;incorrect local sequence number in the Link Layer Discovery Protocol (LLDP).</p>\n\n<p>This product addresses an issue where boot mode is not&nbsp;restored to the default value after a factory reset.</p>\n\n<p>This product addresses an issue where the F1 help messages&nbsp;&quot;Number of VFs per PF&quot; and &quot;Legacy Boot Protocol&quot; option display incorrectly in Japanese and Simplified Chinese languages.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE SNMP 代理程式 (hp-snmp-agents) 彙集了多個以 SNMP 通訊協定為基礎的代理程式及工具，可讓您透過 SNMP 來監控風扇、電源供應器、溫度感應器以及其他管理事件。另外，提供下列項目： 基礎及伺服器代理程式、儲存子系統代理程式、網路子系統代理程式、SNMP 動態載入模組及網路支援應用程式。"},{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ko","x_late":"HPE SNMP 에이전트(hp-snmp-agents)는 SNMP를 통해 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하게 하는 SNMP 프로토콜 기반 에이전트 및 도구 모음입니다. 이 외에도 파운데이션 및 서버 에이전트, 스토리지 하위 시스템 에이전트, 네트워크 하위 시스템 에이전트, SNMP 동적 로드 모듈 및 웹 지원 응용 프로그램 등을 제공합니다."},{"lang":"cn","x_late":"HPE SNMP Agents (hp-snmp-agents) 是一系列基于 SNMP 协议的代理程序和工具，能够通过 SNMP 监控风扇、电源、温度传感器和其他管理事件。它还提供了以下程序： 基础架构和服务器代理程序、存储子系统代理程序、网络子系统代理程序、SNMP 动态加载模块和 Web 支持应用程序。"},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、SNMPプロトコル ベースのエージェント、およびファンの監視、電源、温度センサー、およびその他管理イベントをSNMP経由で行うツールを集めたものです。 また、次の機能も提供します。 基本およびサーバーエージェント、ストレージ サブシステムエージェント、ネットワークサブシステムエージェント、SNMP Dynamically Loaded Module、およびWebサポート アプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1290841","datemodified":"2021-03-22T15:56:37","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"1af19d659696c51d51b8d4fc129a1a07","name":"hp-snmp-agents-10.92-679.5.sles12.x86_64.rpm","release":"2021-03-22T15:50:09","revision":"0","sha1sum":"67ad2d3022a123b6249c1b45a96192f14fbcb4ff","size":"1MB","target_guids":[],"type_of_change":"1","version":"10.9.2"}],"id":{"product":"3e563464a2c34e22b29e876df5230ef9","version":"75133a9e4b2748378f5e31021304878f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE SNMP 代理程式（適用於 SUSE Linux Enterprise Server 12）"},{"lang":"en","x_late":"HPE SNMP Agents for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12용 HPE SNMP Agent"},{"lang":"cn","x_late":"用于 SUSE LINUX Enterprise Server 12 的 HPE SNMP Agents"},{"lang":"ja","x_late":"HPE SNMPエージェント for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-07T14:19:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>&nbsp;the hp-snmp-agents service version 10.9.0 on an HPE ProLiant Gen9 Server or an HPE Synergy Gen9 Compute Node may experience a segfault after installation or restart of the hp-snmp-agents service. cmahostd or cmapeerd process will be killed after the segfault.&nbsp; Pleaer review customer advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00098957en_us\" style=\"color:#0563c1; text-decoration:underline\">a00098957en_us</a>&nbsp;for additional details.</li>\n\t<li>The OS version reported by hp-snmp-agents reported a&nbsp;mismatch with the newer Linux OS distros. i.e., &quot;SUSE Linux Enterprise Server 12&quot; v.s &quot;SUSE Linux Enterprise Server 12 SP5&quot;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3658752","datemodified":"2021-01-27T07:55:22","file_list":["Capitola-Release-1.27.bin.fw","cp046384.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"aa0489c5eaa0f8212f8df6720ff662ee","name":"cp046384.exe","release":"2021-01-27T07:41:05","revision":"0","sha1sum":"dcaf8eab7045c915e3a4c8c76da06ad5e705b1f2","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"id":{"product":"e79fad26938d4b788f99ac1b9d5aa529","version":"f26e96faa1354fc5b9bf5fb0ed0c21b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-03T13:03:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>support added for Gen10Plus servers</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, NCSI, and CCM code running under vSphere 6.5, 6.7, and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9685239","datemodified":"2021-01-21T07:51:41","file_list":["/CP045013_BUILD_13.data","/CP045013.vmexe","/CP045013.vmexe64","/CP045013.vmfile","/CP045013_VMw.zip","/CP045013.xml","/payload.json","/CP045013_VMw.zip/index.xml","/CP045013_VMw.zip/vendor-index.xml","/CP045013_VMw.zip/metadata.zip","/CP045013_VMw.zip/vib20/CP045013/HPE_bootbank_CP045013_1.28.6.13-7.0.0.15843807.vib","/CP045013_VMw.zip/metadata.zip/vendor-index.xml","/CP045013_VMw.zip/metadata.zip/vmware.xml","/CP045013_VMw.zip/metadata.zip/vibs/CP045013-7224660966313214503.xml","/CP045013_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045013_1.28.6.13-7.0.0.15843807.xml"],"md5sum":"ce28c2452eb153203bab072c15fd6bfb","name":"CP045013.zip","release":"2021-01-21T07:49:05","revision":"0","sha1sum":"9a1ccc2766df74cdbac5ac003ef0764b17116294","size":"9MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"1.28.6","vib_list":[{"name":"CP045013","version":"1.28.6.13-7.0.0.15843807"}]}],"id":{"product":"1a455792d85d4dea8d7373fc92fb5b20","version":"648f0b90d7c2438b82851940e28f4419"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGE"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGE"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGE"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGE"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGE"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGE"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGE"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK, and MK001920GWHRU Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK, およびMK001920GWHRUドライブのファームウェアを提供します。 "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3119960","datemodified":"2020-12-16T13:14:20","file_list":["cp045773.xml","cpqsetup.exe","M5100SGE.rel","payload.json","setup.dll"],"md5sum":"0084380853dbeceff9022deb9dec6cb3","name":"cp045773.exe","release":"2020-12-16T13:05:05","revision":"0","sha1sum":"d111c00e3f04f47cfae272091bd2a019e55aceec","size":"2MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"0","version":"HPGE"}],"id":{"product":"349d4407749e4a9fa71df176f3e03e78","version":"c5df58d0669a49d081f5c556a573b91e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant </strong></a><strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T14:40:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fix to issue in bootloader download during power loss. &nbsp;</li>\n\t<li>Change IDF Word 106 report 4K TU for 4/8TB drives to align with Microsoft SQL requirement.</li>\n\t<li>Improvements to error exception.</li>\n\t<li>Improvements to Secure lock fix during multi-thread read tests with high freq. power cycling.</li>\n\t<li>HPGE includes a fix to improve the ability of the drive firmware to find and repair errors on the drive.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.2829.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE\r\n\r\n","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2&nbsp;&nbsp;Adapter</td>\n\t\t\t<td>80009837</td>\n\t\t\t<td>1.2829.0</td>\n\t\t\t<td>8.10</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td>\n\t\t\t<td>800093DD</td>\n\t\t\t<td>1.2829.0</td>\n\t\t\t<td>8.10</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T&nbsp;&nbsp;Adapter</td>\n\t\t\t<td>80001099</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td>\n\t\t\t<td>80001097</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel(R) I350 Gigabit Network Connection (2-port)</td>\n\t\t\t<td>8000108E</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel(R) I350 Gigabit Network Connection (4-port)</td>\n\t\t\t<td>8000108F</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2829.0 includes: Boot Agent: I40E - v1.1.18&amp; UEFI Drivers: 40GbE - v4.4.12.</p>\n\n<p>The combo image v1.2839.0 includes: Boot Agent: 1GbE - v1.5.88 &amp; UEFI Drivers: 1GbE - v9.4.06.</p>\n"}],"files":[{"bytes":"11173777","datemodified":"2021-01-21T09:51:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/CP044895.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/CP044895.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_E810_CQDA2_2p24_PLDMoMCTP_800059DB.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_E810_CQDA2_OCP_2p24_NCSIwPLDMoMCTP_800059D4.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_E810_XXVDA2_SD_2p24_PLDMoMCTP_800059DF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_E810_XXVDA2_SD_OCP_2p24_NCSIwPLDMoMCTP_800059DE.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_E810_XXVDA4_FH_2p24_PLDMoMCTP_800059D9.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000108E.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000108E.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000108F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000108F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_X710DA2_8p10_CFGID7p2_K97470_800093DD.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_X710DA2_OCP3_8p10_CFGID7p2_K97342_80009837.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_i350T4_K68277_80001099.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_i350T4_K68277_80001099.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001097.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001097.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.22.11-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044895.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044895.scexe"],"md5sum":"569b1f88e9cab2fcfb13cb91c7e3541a","name":"firmware-nic-is-intel-1.22.11-1.1.x86_64.rpm","release":"2021-01-21T09:38:04","revision":"0","sha1sum":"ba19c52d9457402b7bb5a5dfe4a22f40c88908d5","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"0","version":"1.22.11"}],"id":{"product":"eeaaff922a754e178b46a3315fd0a64a","version":"bed764d3079941028e604378e290a79b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP044895.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP044895.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP044895<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP044895.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ OCP3 Adapter for HPE</li>\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ Adapter for HPE&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 15 SP2.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8, Update 2 and Update 3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100964","datemodified":"2021-03-08T18:02:04","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"7d01d1f1d7997fdf297c2e45190cb822","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"01cac2c76a503b9065e5455abd6888535fab2e6a","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100969","datemodified":"2021-03-08T17:59:24","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"d006b6949e0a390a0252a4f6b56629d2","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"105f32e3b2493ef3a74fc1642d2fee9f46a557fc","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"2d95bd349a5f487bbf7bbf3c783e4857","version":"2518ca8f7bf64c0180e2fcefe647aa86"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and Red Hat Enterprise Linux 7 Update 9.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"415099","datemodified":"2019-01-14T15:31:52","file_list":["./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/.hpsetup","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/CP038726.xml","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/PICGen9_1.0.9s.hex","./usr/lib/i386-linux-gnu/firmware-powerpic-gen9-1.0.9-10.1/hpsetup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038726.scexe"],"md5sum":"725937308ebabeb8f14a9854449459f8","name":"firmware-powerpic-gen9-1.0.9-10.1.i386.rpm","release":"2019-01-31T00:00:00","revision":"1","sha1sum":"883dc311069904fb12c53b1bfdc3680860427ee8","size":"405KB","target_guids":[],"type_of_change":"0","version":"1.0.9"}],"id":{"product":"b7238ec8b07746d28a0d044f81b28100","version":"fbe0f034e17d46b591b978c2e2152021"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (ams) and HPE SNMP Agents (hp-snmp-agents) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key. To use with HPE SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</p>\n\n\t<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (AMS)およびHPE SNMPエージェント(SNMP Agents)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。HPE SUM 7.6.0またはそれ以前のバージョンを使用するには、\\hp\\swpackages内のコンポーネントをUSBキーにコピーしてください。</p>\n\n\t<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Linux - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-02T05:54:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE 系統狀況應用程式與命令列公用程式 (hp-health) 彙集了應用程式及工具，可讓您監視風扇、電源供應器、溫度感應器及其他管理事件。此外，亦提供一系列命令列公用程式： ProLiant 開機組態公用程式 (hpbootcfg)、ProLiant 管理命令列介面公用程式 (hpasmcli)、ProLiant 整合式管理記錄 (IML) 公用程式 (hplog) 及 UID (藍色) 燈光公用程式 (hpuid)。"},{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ko","x_late":"HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티(hp-health)는 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하도록 하는 응용 프로그램 및 도구 모음입니다. 또한 다음과 같은 명령줄 유틸리티 모음을 제공합니다. ProLiant 부팅 구성 유틸리티(hpbootcfg), ProLiant 관리 명령줄 인터페이스 유틸리티(hpasmcli), ProLiant 통합 관리 로그(IML) 유틸리티(hplog) 및 UID(블루) 라이트 유틸리티(hpuid)"},{"lang":"cn","x_late":"HPE System Health Application and Command Line Utilities (hp-health) 是一系列应用程序和工具，能够监控风扇、电源、温度传感器和其他管理事件。它还提供了命令行实用程序集： ProLiant 启动配置实用程序 (hpbootcfg)、ProLiant Management Command Line Interface Utility (hpasmcli)、ProLiant Integrated Management Log (IML) Utility (hplog) 和 UID (blue) Light Utility (hpuid)。"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。  また、ProLiantブートコンフィギュレーションユーティリティ（hpbootcfg）、ProLiantマネジメントコマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（青）ランプユーティリティ（hpuid）を集めたコマンドラインユーティリティも提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"358956","datemodified":"2020-04-20T22:14:52","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"172af3f51aecd77817f6fd4bee9f7ad7","name":"hp-health-10.92-8.8.rhel7.x86_64.rpm","release":"2020-04-21T03:10:05","revision":"0","sha1sum":"4cba6f5d5661d2156b9615315c3731459fbd3cf1","size":"350KB","target_guids":[],"type_of_change":"0","version":"10.9.2"}],"id":{"product":"4a40e009928d473f96b4a66d5f8ed116","version":"ea29e2bfee6c4169a1dd36593554df18"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。 </P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器的 HPE 系統健康狀況應用程式與命令列公用程式"},{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE System Health应用程序和命令行工具"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-21T13:52:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Modified the loop initial values in hpasmcli from 2 to 0.</li>\n\t<li>Modifications to check the read and write variables to match RBSU in Legacy and UEFI mode</li>\n\t<li>Updated the hpasmcli check string to correctly report the impitool information.</li>\n\t<li>Remove the redundant serial embedded and com ports</li>\n\t<li>Addressed&nbsp;IML message size limitation from 36 to 212 bytes</li>\n\t<li>Support for hp-health in OS security boot</li>\n\t<li>Added supporting &ldquo;quote mark&rdquo; in SET NAME command</li>\n\t<li>Enabled to set PXE as boot first&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17267026","datemodified":"2021-01-28T16:43:53","file_list":["/CP045672_BUILD_3.data","/CP045672.vmexe","/CP045672.vmexe64","/CP045672.vmfile","/CP045672_VMw.zip","/CP045672.xml","/payload.json","/CP045672_VMw.zip/index.xml","/CP045672_VMw.zip/vendor-index.xml","/CP045672_VMw.zip/metadata.zip","/CP045672_VMw.zip/vib20/CP045672/HPE_bootbank_CP045672_HPG8.3-7.0.0.15843807.vib","/CP045672_VMw.zip/metadata.zip/vendor-index.xml","/CP045672_VMw.zip/metadata.zip/vmware.xml","/CP045672_VMw.zip/metadata.zip/vibs/CP045672-235800727328133730.xml","/CP045672_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045672_HPG8.3-7.0.0.15843807.xml"],"md5sum":"7d23e3440289c4a76fb6e4723e7f12e8","name":"CP045672.zip","release":"2021-01-28T16:41:05","revision":"0","sha1sum":"0f55a29af8410060456b7817ed9e283e5593581c","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP045672","version":"HPG8.3-7.0.0.15843807"}]}],"id":{"product":"c19eee3c7a1046a4aeaff35e462fce56","version":"fc8388bdca8b4c7dafd1c7c5d9a972c9"},"installation":{"command":"CP040658.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:11:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5905520","datemodified":"2020-11-04T10:20:09","file_list":["P99_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046137.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"83288eebdd65b44465d2f7f0a0da9ec8","name":"cp046137.exe","release":"2020-11-04T10:01:33","revision":"0","sha1sum":"52b7083f479269231f1de340016f99f8228fcc9d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"37828e7bce5241f6a19b4fa05756658e","version":"ac7579ec4a4f4ace9ba3a965a7e6d30d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML110 Gen9 (P99)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-23T09:09:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel NVMe Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"39340","datemodified":"2021-01-22T09:35:28","file_list":["/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip","/cp045822.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/vib20/brcmnvmefc/EMU_bootbank_brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vmware.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vibs/brcmnvmefc--8683936915530851429.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/bulletins/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807.xml"],"md5sum":"dc2f46ed0125eb6ac45a0ba099050bd4","name":"cp045822.zip","release":"2021-01-22T09:34:05","revision":"0","sha1sum":"43bec7bc2b7edefcb83e4fea2a16815af20f1167","size":"38KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccf06fbb4","20a6e8e4-bf33-4c71-a6bf-d9ec8e5a330c"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmnvmefc","version":"12.8.329.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"6388aca0e9384416957e1de0a3b220b2","version":"1cd2d1f20c5446e8b6d9365558dd6eb7"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel NVMe driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-02T08:51:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.329.0</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmnvmefc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-ELX-brcmnvmefc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD2"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;</strong> None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4817948","datemodified":"2020-12-13T16:42:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/CP045488.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/TA15SEe0HPD2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045488.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045488.scexe"],"md5sum":"48cccc901e1f6aebff5446f921f7be65","name":"firmware-hdd-852266afdf-HPD2-5.1.x86_64.rpm","release":"2020-12-13T16:29:06","revision":"0","sha1sum":"5eb701616307a809583f042b72963ba01a42f547","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"5525dd3ac4024adeb1f8ec72b9fd1236","version":"fbef3cf35c0e4084b972592ff37286b2"},"installation":{"command":"CP041561.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MM1000JFJTH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3537888","datemodified":"2020-12-16T14:17:20","file_list":["cp045564.xml","cpqsetup.exe","payload.json","SAVGNSD3.rel","setup.dll"],"md5sum":"cc03f2eb690dfd1e431421f8af4ef865","name":"cp045564.exe","release":"2020-12-16T14:09:04","revision":"0","sha1sum":"22c35deb8a305d28479c81727f03649eb1210ed4","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448"],"type_of_change":"0","version":"HPD3"}],"id":{"product":"05aa24e5db0c41fc91f79deb60685a31","version":"858d3a672ac64df2ba1f62ee19b6afb6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:55:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 15 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"769571","datemodified":"2020-12-02T16:43:14","file_list":["./lib/modules/4.12.14-23-default","./lib/modules/4.12.14-23-default/updates","./lib/modules/4.12.14-23-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"11d1048581c1985daa7f26cb42acaed2","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles15-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"9db59e2f509cb259e3ea8d75f376d19a53f48b0a","size":"751KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"772720","datemodified":"2020-12-02T16:48:05","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"3291ed2788559da9e62e41529797f535","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles15sp1-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"e5e51261d235c63d78467e87bf12d796d63e4789","size":"754KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"762125","datemodified":"2020-12-02T16:36:54","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"80ffa38dceb25a6dfb56dd2a7f1fa96b","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles15sp2-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"f34aa75fdd92a82f4d3355772513c01993a895b7","size":"744KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"506d73f1a1f34beeb329c1ead8b7d250","version":"bf4ca757b81c4223b9a3724013c57191"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T13:16:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含的套件 QLogic 光纖通道主機匯流排配接卡的 Linux 作業系統上提供對 Smart SAN 的支援。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Linux operating systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 QLogic 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"ja","x_late":"このパッケージは、LinuxオペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"18701","datemodified":"2019-10-07T05:58:42","file_list":["./opt/hpe/ql_smartsan/ql_ss_enablement","./opt/hpe/ql_smartsan/qlssen.sh","./opt/hpe/ql_smartsan/qlssen.txt","./usr/share/smartupdate/hpe-qlogic-smartsan-enablement-kit/component.xml"],"md5sum":"75ec07baf57e880d33c45584bca63fd2","name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","release":"2019-11-05T00:00:00","revision":"1","sha1sum":"58ed66750b9ce95f63d622d8692b187fde589d16","size":"18KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd61cbbea"],"type_of_change":"0","version":"3.3-3"}],"id":{"product":"8be880867f274999951d42eb0e3b0aa8","version":"c2b714347dc14d0c88239e450fdfdb10"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release. &nbsp;They are&nbsp;now a 64 bit&nbsp;specific kit.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the QLogic Smart SAN enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hpe-qlogic-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>For detailed information about configurable components, see the&nbsp;<em>Smart Update Manager User Guide </em>at <a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>.</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-qlogic-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n"},{"lang":"ja","x_late":"<p>このリリースではイネーブルメントキットに変更がありました。 現在、64 bit固有のキットになりました。   このコンポーネントをインストールする前に以前のキットをアンインストールすることをお勧めします。<br />\n<br />\nQLogic Smart SANイネーブルメントRPMをアンインストールするには、次のコマンドを使用します：</p>\n\n<p>   # rpm -e hpe-qlogic-smartsan-enablement-<version>.noarch.rpm</p>\n\n<p>これは構成可能コンポーネントです。  Smart SAN 機能を有効/無効にするための構成ファイルが必要です。  構成を実行できない場合、Smart SANの現状が記載され、実行が完了します。  それ以上の処置は不要です。</p>\n\n<p>構成コンポーネントの詳細については、<a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>の『<em>Smart Update Manager User Guide（Smart Update Managerユーザーガイド）</em>』を参照してください。</p>\n\n<p><strong>ProLiant の HPE サービスパックの外部コンポーネントの実行</strong>:</p>\n\n<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. インストールするには、プロンプトで以下のコマンドを入力してください：<br />\n<br />\n                    # rpm -ivh hpe-qlogic-smartsan-enablement-kit-<version>.x86_64.rpm<br />\n<br />\n                    例：# rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />\n<br />\n                    Installation complete</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 QLogic SmartSAN 啟用套件"},{"lang":"en","x_late":"HPE QLogic Smart SAN enablement kit for Linux"},{"lang":"ko","x_late":"Linux용 QLogic SmartSAN 인에이블먼트 키트"},{"lang":"ja","x_late":"HPE QLogic Smart SAN イネーブルメントキット（Linux）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2532","subdev":"338E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c338e","type":"pci","ven":"1077"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-23T09:57:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added Support to RHEL8 and SLES15SP1</p>\n\n<p>Updated to version 3.3-3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Support to RHEL8 and SLES15SP1</p>\n\n<p>Updated to version 3.3-3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpe-qlogic-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.5"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"1537735","datemodified":"2020-07-10T14:02:48","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp044790.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"b9922ce846c718ce94ae09b0e98bf3af","name":"cp044790.zip","release":"2020-07-10T14:02:05","revision":"0","sha1sum":"30a774e75d8e8128da15c0e633b607df5bcf3a67","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"74bcebdbd1974e4b8af3429e65c84801","version":"9376aceb3c804725865993f4fa69ead0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:30:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"923698","datemodified":"2021-01-22T05:00:00","file_list":["./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel8/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/75","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66.1","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b.1","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8.1","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"9d7bdf0390e3ea3152b91c1637833733","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel8.x86_64.rpm","release":"2021-01-22T04:56:39","revision":"0","sha1sum":"884d5aed28ff4d6ca892200c731b64313e63c824","size":"902KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"0789ba677e9748e99f7b62253abbd63d","version":"6725749b27bb4bacbccf254f52cb761b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:47:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1264.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."},{"lang":"ja","x_late":"Agentless Management Service（AMSD）は、Integrated Lights Out 5（iLO 5）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2864848","datemodified":"2021-03-22T15:36:19","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"86d4bec00b5d48a618b0e28ef6c3ba36","name":"amsd-2.4.1-1571.4.sles15.x86_64.rpm","release":"2021-04-15T00:00:00","revision":"1","sha1sum":"382ebf066bd2af3af85accc3c50c357cbd9b11f6","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"2.4.1"}],"id":{"product":"cd4b5a9c9ed9405abbc5be7a9f037870","version":"5ed6addf110a4d4a92681fad0edc66ca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-21T12:58:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This release contains the following enhancements:</p>\n\n<ul>\n\t<li>Enhance the robust communication with iLO. The enhancement has a proper process exist and OS signal handling.</li>\n\t<li>Enhance the SMA logging system for better recording of the communication events.</li>\n\t<li>The AMSD reports the Open NIC controllers SN to align with iLO for avoiding the un-sync information.</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed a small amount of memory leak as outlined in the Customer Advisory,&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\">a00053824en_us</a></li>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp;</li>\n\t<li>The cpqIde service not able to start while the AMSD configuration is agent mode.</li>\n\t<li>Addressed&nbsp;buffer overflow issues in select&nbsp;corner cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This release contains the following enhancements:</p>\n\n<ul>\n\t<li>Enhance the robust communication with iLO. The enhancement has a proper process exist and OS signal handling.</li>\n\t<li>Enhance the SMA logging system for better recording of the communication events.</li>\n\t<li>The AMSD reports the Open NIC controllers SN to align with iLO for avoiding the un-sync information.</li>\n</ul>\n","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed a small amount of memory leak as outlined in the Customer Advisory,&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\">a00053824en_us</a></li>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp;</li>\n\t<li>The cpqIde service not able to start while the AMSD configuration is agent mode.</li>\n\t<li>Addressed&nbsp;buffer overflow issues in select&nbsp;corner cases.</li>\n\t<li>Metadata update to address new AMD servers not listed in the supported platforms list.&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892966","datemodified":"2021-03-08T18:01:40","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"078f24ffb9ccfbf0ae6a565c9847cb60","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"b08a628ef5265116ee802c13d05745b33cc0005c","size":"872KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"871242","datemodified":"2021-03-08T18:13:31","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"c286e9edc89302d9b790c48c568f0f93","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"3561023f17012264bb3f0f3feef4a604454ca46a","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"61d3db3934a9409ea2efff88ec08bbc6","version":"cab99dcef31246e79bbcb163a81e1b59"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート548SFP+アダプター（P11338-B21）</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"3079739","datemodified":"2021-01-19T09:33:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/CP045201.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045201.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045201.scexe"],"md5sum":"3b6efcc79f045d18c47e901285eb52da","name":"firmware-nic-mellanox-eth-only-mft-1.0.4-1.1.x86_64.rpm","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"dba0af99ead7fb98fc88faf141dc1ce1c191ffcc","size":"2MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.4"}],"id":{"product":"35cb34a457a347fd86df4f560cf6cf57","version":"e57b12ec49094f8a9d37a652d98a550a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Linux x86_64）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T20:24:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.28.1002:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.28.1002:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"此適用於 Linux 的 HPE System Management Homepage (系統管理首頁) 範本 (hp-smh-templates) 包含適用於伺服器、管理處理器、NIC 與儲存子系統的 System Management Homepage 範本。此範本匯集了 html、javascript 與 php 檔案，可作為圖形使用者介面以顯示由各個子系統代理程式所提供的許多 SNMP 資料。所以此套件是相依於 hp-snmp-agents 套件。此套件也相依於 hpsmh 套件以將頁面提供給瀏覽器。   "},{"lang":"en","x_late":"This HPE System Management Homepage Templates for Linux (hp-smh-templates) contains the System Management Homepage Templates for Server, Management processor, NIC and Storage subsystems. The templates are a collection of html, javascript and php files that act as a GUI to display much of the SNMP data provided by each subsystems agent(s). As such this package is dependant on the hp-snmp-agents package. This package is also dependant on the hpsmh package to serve the pages to the browser.   "},{"lang":"ko","x_late":"Linux용 HPE System Management Homepage 템플릿(hp-smh-templates)에는 서버, 관리 프로세서, NIC 및 스토리지 하위 시스템용 System Management Homepage 템플릿이 포함됩니다. 템플릿은 각 하위 시스템 에이전트에서 제공하는 많은 SNMP 데이터를 표시하기 위한 GUI의 역할을 하는 html, javascript 및 php 파일의 컬렉션입니다. 따라서 이 패키지는 hp-snmp-agents 패키지에 따라 다릅니다. 또한, 이 패키지는 브라우저에 페이지를 제공하기 위한 hpsmh 패키지에 따라서도 다릅니다.   "},{"lang":"cn","x_late":"此HPE System Management Homepage Templates for Linux (hp-smh-templates) 包含适用于服务器、管理处理器、NIC 和存储子系统的系统管理主页模板。这些模板包括 html、javascript 和 php 文件，可作为 GUI 显示每个子系统代理程序提供的大部分 SNMP 数据。同样，该软件包也依赖于 hp-snmp-agents 软件包。此外，该软件包还依赖于 hpsmh 软件包为浏览器提供页面。   "},{"lang":"ja","x_late":"サーバー、マネジメントプロセッサー、NIC、およびストレージ サブシステム用のHPE System Management Homepageテンプレート for Linux （hp-smh-templates）には、サーバーのSystem Management Homepageテンプレート、マネジメントプロセッサー、NIC、およびストレージ サブシステムが含まれています。 テンプレートは、各サブシステムエージェントで提供される多くのSNMPデータを表示させるためのGUI として機能するhtml、javascript、およびphpファイルの集まりです。 このパッケージ自体は、hp-snmp-agentsパッケージに含まれるものです。 このパッケージは、ブラウザーにページを提供するためのhpsmhパッケージにも含まれています。   "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"3618471","datemodified":"2019-02-21T02:39:26","file_list":["./opt/hp/hp-smh-templates","./opt/hp/hp-smh-templates/bin","./opt/hp/hp-smh-templates/bin/add-sudo-entries","./opt/hp/hp-smh-templates/bin/del-sudo-entries","./opt/hp/hp-smh-templates/hp-smh-templates.license","./opt/hp/hp-smh-templates/hprpm.xpm","./opt/hp/hpsmh/data/cgi-bin/snmpagent","./opt/hp/hpsmh/data/cgi-bin/snmpagent/SetSNMPData.cgi","./opt/hp/hpsmh/data/cgi-bin/snmpagent/SetSNMPData.cgis","./opt/hp/hpsmh/data/htdocs/ginkgotest","./opt/hp/hpsmh/data/htdocs/ginkgotest/csginkgotest.php.en","./opt/hp/hpsmh/data/htdocs/hmanics","./opt/hp/hpsmh/data/htdocs/hmanics/common","./opt/hp/hpsmh/data/htdocs/hmanics/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/navtable.js","./opt/hp/hpsmh/data/htdocs/hmanics/common/numcnvrt.js","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/common/tables.js","./opt/hp/hpsmh/data/htdocs/hmanics/dt5enums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/dt5enums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00010.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00201.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00202.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00203.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00204.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/IMA00205.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/NicAg.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/TOPARROW.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/default.css","./opt/hp/hpsmh/data/htdocs/hmanics/help/default_ns.css","./opt/hp/hpsmh/data/htdocs/hmanics/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00010.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00201.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00202.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00203.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00204.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/ima00205.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/welcome.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/welcome.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_dpns.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_dpns.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_nvp10.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab0.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab3.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab4.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab5.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tab6.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tabs.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_tabs.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc3.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whd_toc4.gif","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whftdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whftdata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfts.xml","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata1.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whfwdata2.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidx.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whidx.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtdata0.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtdata0.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtoc.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whdata/whtoc.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfbody.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfdhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfform.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfform.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whfhost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whform.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whhost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whibody.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whidhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whidhtml.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whiform.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whiform.htm.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whihost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whlang.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whmozemu.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whmsg.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whphost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproj.xml.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproj.xml.ja","./opt/hp/hpsmh/data/htdocs/hmanics/help/whproxy.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whstart.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whstub.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whtdhtml.htm.en","./opt/hp/hpsmh/data/htdocs/hmanics/help/whthost.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whtopic.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whutils.js","./opt/hp/hpsmh/data/htdocs/hmanics/help/whver.js","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.js.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.js.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.snmp.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/hmanics.snmp.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/hoenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/hoenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/ifenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/ifenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/images","./opt/hp/hpsmh/data/htdocs/hmanics/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmanics/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmanics/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmanics/nc-cmmn.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-cmmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-if.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-if.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-log.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-log.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-phy.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-phy.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-sngl.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-sngl.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nc-tmmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/nc-tmmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nicenums.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nicenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/nichead.js.en","./opt/hp/hpsmh/data/htdocs/hmanics/nichead.js.ja","./opt/hp/hpsmh/data/htdocs/hmanics/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmanics/vt.php.en","./opt/hp/hpsmh/data/htdocs/hmanics/vt.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-secur.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-secur.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-sinfo.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/cf-sinfo.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common","./opt/hp/hpsmh/data/htdocs/hmaserv/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-asset.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-asset.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-detl.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-detl.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info-cclass.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info-cclass.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info1.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/em-info1.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/emenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/emenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-commn.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-commn.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-res.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ex-res.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/heenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/heenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help","./opt/hp/hpsmh/data/htdocs/hmaserv/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/default.css","./opt/hp/hpsmh/data/htdocs/hmaserv/help/defns.css","./opt/hp/hpsmh/data/htdocs/hmaserv/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00011.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00011.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00012.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00012.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00013.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00013.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00014.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00014.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00015.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00015.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00016.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00016.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00017.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00017.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00018.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00018.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00019.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00019.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00020.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00020.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00021.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00021.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00022.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00022.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00023.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00023.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00024.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00024.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00046.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00046.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00080.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00080.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00081.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00081.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00082.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00082.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00083.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00083.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00084.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00084.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00085.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00085.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00116.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00116.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00117.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00117.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00150.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/ima00150.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servcont.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servcont.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servidx.htm.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/servidx.htm.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/toparrow.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/toparrow.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/hmaserv/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/help/whnonie4.css","./opt/hp/hpsmh/data/htdocs/hmaserv/hemenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/hemenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/hmaserv.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/hmaserv.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/images","./opt/hp/hpsmh/data/htdocs/hmaserv/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmaserv/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmaserv/ms-flop.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ms-flop.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-env.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-env.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-fan.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-fan.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-iml.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-iml.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-pconv.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-pconv.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-power.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-power.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-range.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-range.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rawlg.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rawlg.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rblog.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rblog.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rbnic.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rbnic.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rboot.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rboot.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rcomm.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-rcomm.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-recov.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-recov.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-ribrd.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/rc-ribrd.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cart.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cart.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cpu.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-cpu.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-mem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-mem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-resmem.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sb-resmem.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/seenums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/seenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sienums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sienums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/sm2enums.js.en","./opt/hp/hpsmh/data/htdocs/hmaserv/sm2enums.js.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmaserv/ut-info.php.en","./opt/hp/hpsmh/data/htdocs/hmaserv/ut-info.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor","./opt/hp/hpsmh/data/htdocs/hmastor/common","./opt/hp/hpsmh/data/htdocs/hmastor/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/daenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/daenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/drive.gif","./opt/hp/hpsmh/data/htdocs/hmastor/drvblink.gif","./opt/hp/hpsmh/data/htdocs/hmastor/fcaenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/fcaenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help","./opt/hp/hpsmh/data/htdocs/hmastor/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/default.css","./opt/hp/hpsmh/data/htdocs/hmastor/help/defns.css","./opt/hp/hpsmh/data/htdocs/hmastor/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/hmastor/help/hotplug.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00041.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00041.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00042.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00042.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00043.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00043.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00044.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00044.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00046.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00046.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00047.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00047.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00048.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00048.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00049.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/ima00049.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/major_32.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storcont.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storcont.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storidx.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storidx.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/storsrch.htm.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/storsrch.htm.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/toparrow.gif","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/hmastor/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/hmastor/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.js.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.js.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/hmastor.snmp.php","./opt/hp/hpsmh/data/htdocs/hmastor/hotplug.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/idenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/idenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/images","./opt/hp/hpsmh/data/htdocs/hmastor/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/crith.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/failed.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ima.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/line1.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/nic.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/ok.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/perf.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/recov.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/hmastor/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/hmastor/images/warth.gif","./opt/hp/hpsmh/data/htdocs/hmastor/isenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/isenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dabox.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dabox.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dacmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dacmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dactl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dactl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dalog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dalog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-damnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-damnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-daphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-daphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-drvbx.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-drvbx.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtape.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtape.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtlib.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-dtlib.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccnt.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccnt.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccon.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fccon.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fces.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fces.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fclog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fclog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcss.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcss.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcsw.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-fcsw.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftape.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftape.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftlib.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftlib.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ftmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idcmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idcmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idlog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idlog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-idphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscmn.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscmn.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscxn.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-iscxn.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isinit.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isinit.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isins.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isins.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ismnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-ismnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isnod.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isnod.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isssn.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-isssn.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-raids.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-raids.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sabox.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sabox.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sahba.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sahba.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-salog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-salog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-samnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-samnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-saphy.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-saphy.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sas.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sas.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sasc.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sasc.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-satap.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-satap.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sclog.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sclog.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scmnu.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scmnu.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsi.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsi.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsic.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-scsic.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sctl.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/ms-sctl.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/sacenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/sacenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/scsenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/scsenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/ssenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/ssenums.js.ja","./opt/hp/hpsmh/data/htdocs/hmastor/subframe.php.en","./opt/hp/hpsmh/data/htdocs/hmastor/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/hmastor/tpenums.js.en","./opt/hp/hpsmh/data/htdocs/hmastor/tpenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent","./opt/hp/hpsmh/data/htdocs/webagent/agent.php.en","./opt/hp/hpsmh/data/htdocs/webagent/agent.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/cf-clstr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cf-clstr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/cf-swver.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cf-swver.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/clsenums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/clsenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common","./opt/hp/hpsmh/data/htdocs/webagent/common/compaq.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/compaq.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/cond.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/cond.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/dispbase.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/dispbase.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/helputil.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/helputil.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/navtable.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/navtable.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/numcnvrt.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/numcnvrt.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/oiddefs.inc","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/pagetags.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/parsearg.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/parsearg.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/setitem.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/setitem.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/setmsgs.php.en","./opt/hp/hpsmh/data/htdocs/webagent/common/setmsgs.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/sets.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/sets.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/sorts.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/sorts.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/stditems.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/stditems.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/swtable.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/swtable.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/tables.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/tables.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/common/uidenums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/common/uidenums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/cpqmibmap.txt","./opt/hp/hpsmh/data/htdocs/webagent/cpqthrsh.jar","./opt/hp/hpsmh/data/htdocs/webagent/cpuinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/cpuinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gcchcthr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gcchcthr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gccputhr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gccputhr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/gcmemthr.php.en","./opt/hp/hpsmh/data/htdocs/webagent/gcmemthr.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/groupcfg.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/groupcfg.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/grpcfg.php","./opt/hp/hpsmh/data/htdocs/webagent/help","./opt/hp/hpsmh/data/htdocs/webagent/help/SNMPop.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/about.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/about.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/bsscnbar.js.en","./opt/hp/hpsmh/data/htdocs/webagent/help/bsscnbar.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/cachconf.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/cpuconf.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/default.css","./opt/hp/hpsmh/data/htdocs/webagent/help/defns.css","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/help.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/helpmap.js","./opt/hp/hpsmh/data/htdocs/webagent/help/hostcont.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/hostcont.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/hostidx.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/hostidx.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00000.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00000.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00007.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00007.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00008.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00008.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00009.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00009.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00013.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00013.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00025.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00025.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00030.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00030.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00040.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00040.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00047.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00047.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00054.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00054.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00055.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00055.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00056.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00056.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00057.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00057.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00058.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00058.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00059.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00059.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00090.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00090.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00091.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00091.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00099.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00099.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00100.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00100.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00101.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00101.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00102.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00102.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00103.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00103.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00104.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00104.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00105.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00105.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00106.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00106.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00107.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00107.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00108.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00108.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00109.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00109.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00110.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00110.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00111.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00111.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00112.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00112.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00113.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00113.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00114.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00114.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00115.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00115.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00116.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00116.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00117.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00117.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00118.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00118.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00119.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00119.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00120.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/ima00120.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/navpane2.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/help/navpane2.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/nsdnsfix.jar.en","./opt/hp/hpsmh/data/htdocs/webagent/help/nsdnsfix.jar.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/pagefile.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/pgsectn.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/pgsectn.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/snmpop.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/snmppage.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/toparrow.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.cab.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.cab.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.jar.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.jar.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.zip.en","./opt/hp/hpsmh/data/htdocs/webagent/help/webhelp.zip.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/welcome.gif.en","./opt/hp/hpsmh/data/htdocs/webagent/help/welcome.gif.ja","./opt/hp/hpsmh/data/htdocs/webagent/help/whnonie4.css","./opt/hp/hpsmh/data/htdocs/webagent/images","./opt/hp/hpsmh/data/htdocs/webagent/images/agntlogo.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/backgrnd.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/bttyhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/cfghdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/cfgnav.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/crith.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/critical.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/degraded.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/disabled.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/disabth.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-blck.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-blue.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-grn.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-red.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-wht.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/dot-yllw.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/exhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/expbrd2.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/failed.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/helpptr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ima.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/line1.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/major_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/major_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/mass5.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/masshdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/minor_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/minor_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/mntrhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/nic.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/nichdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/normal_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/normal_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/notslctd.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ntos.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ntoshdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/ok.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/perf.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/recov.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/recvrhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/sbhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/slctlft.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/slctrt.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/sysbrd2.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/utilhdr.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/utnav.gif","./opt/hp/hpsmh/data/htdocs/webagent/images/warning.jpg","./opt/hp/hpsmh/data/htdocs/webagent/images/warth.gif","./opt/hp/hpsmh/data/htdocs/webagent/index.tpl.en","./opt/hp/hpsmh/data/htdocs/webagent/index.tpl.ja","./opt/hp/hpsmh/data/htdocs/webagent/ldskinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/ldskinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/lxsnmpconf.php.en","./opt/hp/hpsmh/data/htdocs/webagent/lxsnmpconf.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/meminfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/meminfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/menu.php.en","./opt/hp/hpsmh/data/htdocs/webagent/menu.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/ms-space.php.en","./opt/hp/hpsmh/data/htdocs/webagent/ms-space.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/netinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/netinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/netmenu.php.en","./opt/hp/hpsmh/data/htdocs/webagent/netmenu.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/os-enums.js.en","./opt/hp/hpsmh/data/htdocs/webagent/os-enums.js.ja","./opt/hp/hpsmh/data/htdocs/webagent/pdskinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/pdskinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/procinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/procinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/security.php.en","./opt/hp/hpsmh/data/htdocs/webagent/security.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/securset.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/securset.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/servinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/servinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/setthreshold.php.en","./opt/hp/hpsmh/data/htdocs/webagent/setthreshold.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/setup.php.en","./opt/hp/hpsmh/data/htdocs/webagent/setup.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/snmpagnt.php.en","./opt/hp/hpsmh/data/htdocs/webagent/snmpagnt.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/snmpcfg.xsl","./opt/hp/hpsmh/data/htdocs/webagent/subframe.php.en","./opt/hp/hpsmh/data/htdocs/webagent/subframe.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/tcpinfo.php.en","./opt/hp/hpsmh/data/htdocs/webagent/tcpinfo.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/tpltophp.pl","./opt/hp/hpsmh/data/htdocs/webagent/trap.php.en","./opt/hp/hpsmh/data/htdocs/webagent/trap.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/trapset.htm.en","./opt/hp/hpsmh/data/htdocs/webagent/trapset.htm.ja","./opt/hp/hpsmh/data/htdocs/webagent/tsk-uid.php.en","./opt/hp/hpsmh/data/htdocs/webagent/tsk-uid.php.ja","./opt/hp/hpsmh/data/htdocs/webagent/webagent.php.en","./opt/hp/hpsmh/data/htdocs/webagent/webagent.php.ja","./opt/hp/hpsmh/data/smhutil","./opt/hp/hpsmh/data/smhutil/ginkgochp.inc","./opt/hp/hpsmh/data/smhutil/ginkgoprop.inc","./opt/hp/hpsmh/data/smhutil/ginkgoset.inc","./opt/hp/hpsmh/data/smhutil/ginkgosnmp.inc","./opt/hp/hpsmh/data/smhutil/testdata.txt","./opt/hp/hpsmh/data/webapp-data/hmanics.chpinput.txt","./opt/hp/hpsmh/data/webapp-data/hmaserv","./opt/hp/hpsmh/data/webapp-data/hmaserv/hmaserv.ini","./opt/hp/hpsmh/data/webapp-data/hmastor","./opt/hp/hpsmh/data/webapp-data/hmastor.chpinput.txt","./opt/hp/hpsmh/data/webapp-data/hmastor/hmastor.ini","./opt/hp/hpsmh/data/webapp-data/webagent","./opt/hp/hpsmh/data/webapp-data/webagent/inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/cimomfuncs.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/define.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/footer.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/getcfg.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/grpcfg.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/header.inc","./opt/hp/hpsmh/data/webapp-data/webagent/inc/properties.inc","./opt/hp/hpsmh/data/webapp-data/webagent/webagent.ini","./opt/hp/hpsmh/webapp/hmanics.xml","./opt/hp/hpsmh/webapp/hmaserv.xml","./opt/hp/hpsmh/webapp/hmastor.xml","./opt/hp/hpsmh/webapp/webagent.xml","./usr/share/man/man4/hp-smh-templates.4.gz"],"md5sum":"85b767973f9e6aabd2eb697b26d924df","name":"hp-smh-templates-10.8.1-1487.3.noarch.rpm","release":"2019-02-21T08:40:01","revision":"0","sha1sum":"7088c484f1308844e5cee6a1ce071c6e5244372c","size":"3MB","target_guids":[],"type_of_change":"0","version":"10.8.1"}],"id":{"product":"7481c4f359924b82adf02da5a315552d","version":"915814ba3e3c4667b44af6191061b825"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-smh-templates-&lt;version&gt;.rpm</P>\n<P>To check whether the package is installed type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm –q hp-smh-templates</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-smh-templates</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-smh-templates-&lt;version&gt;.rpm</P>\n<P>パッケージがインストールされているかどうか確認するには、次のようにタイプします。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -q hp-smh-templates</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-smh-templates</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 HPE System Management Homepage (系統管理首頁) 範本"},{"lang":"en","x_late":"HPE System Management Homepage Templates for Linux"},{"lang":"ko","x_late":"Linux용 HPE 시스템 관리 홈 페이지 템플릿"},{"lang":"ja","x_late":"HPE System Management Homepageテンプレート for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-15T16:33:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial support for&nbsp;SUSE LINUX Enterprise Server 15.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P63","value":"HP ProLiant DL370 G6 Server"},{"key":"D22","value":"HP ProLiant ML350 G6 Server"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I24","value":"HP ProLiant WS460c G6 Workstation Blade"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"P69","value":"HP ProLiant SL390s G7 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A15","value":"HP ProLiant DL785 G6 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"A17","value":"HP ProLiant BL685c G6 Server"},{"key":"W07","value":"HP ProLiant DL320 G6 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"I26","value":"HP ProLiant BL2x220c G6 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"J01","value":"HP ProLiant DL120 G7 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"O20","value":"HP ProLiant DL180 G6 Server"},{"key":"I22","value":"HP ProLiant BL280c G6 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"I21","value":"HP ProLiant BL490c G6 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"J01","value":"HP ProLiant ML110 G7 Server"},{"key":"A22","value":"HP ProLiant DL385 G6 Server"},{"key":"O21","value":"HP ProLiant ML150 G6 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O33","value":"HP ProLiant DL160 G6 Server"},{"key":"I14","value":"HP ProLiant BL480c Server"},{"key":"I15","value":"HP ProLiant BL460c Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"O37","value":"HP ProLiant DL165 G7 Server"},{"key":"O37","value":"HP ProLiant SL165z G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"P63","value":"HP ProLiant ML370 G6 Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"O34","value":"HP ProLiant DL170h G6 Server"},{"key":"A14","value":"HP ProLiant BL495c G6 Server"},{"key":"O40","value":"HP ProLiant SL170s G6 Server"},{"key":"A13","value":"HP ProLiant BL465c G6 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"W07","value":"HP ProLiant ML330 G6 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"hp-smh-templates","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33595760","datemodified":"2021-01-28T11:55:55","file_list":["payload.json","U40_2.42_01_23_2021.signed.flash","U40_2.42_01_23_2021.xml"],"md5sum":"0309574d7ae8ebc32a910770c566854f","name":"U40_2.42_01_23_2021.fwpkg","release":"2021-01-28T11:52:17","revision":"0","sha1sum":"09cb3e41ae27cb307ed73ef42ff3dbfa2c73f8ca","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"118ba074c4b3495fbd26210e14a17511","version":"372736fca6d2453c860cd03ce139f4a9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online ROM Flash Smart Component which upgrades the switch firmware on the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"可更新 HPE Express 托架支持交换卡上的交换机固件的在线 ROM 刷新组件"},{"lang":"tw","x_late":"可升級 HPE Express 插槽啟用交換器卡的交換器韌體的線上 ROM 更新智慧型元件"},{"lang":"ko","x_late":"HPE Express Bay Enablement Switch Card에서 스위치 펌웨어를 업그레이드하는 온라인 ROM 플래시 스마트 구성 요소"},{"lang":"ja","x_late":"HPE Express Bay Enablement Switch カード上のスイッチファームウェアをアップグレードする、オンラインROMフラッシュスマートコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online ROM Flash Component for VMware ESXi - HPE Express Bay Enablement Switch Card</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added VMware vSphere 6.7 OS support</p>\n\n<p><strong>Problems Fixed in version 1.78:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"1596709","datemodified":"2018-09-27T22:52:54","file_list":["/CP035193.vmexe","/CP035193.vmfile","/CP035193.xml","/README.txt"],"md5sum":"359cd9136dae137a339fde8ce4980077","name":"CP035193.zip","release":"2018-09-28T03:38:03","revision":"0","sha1sum":"c39b11b3cd940626667e8e04dd97a2cc4a8bd54c","size":"1MB","target_guids":[],"type_of_change":"0","version":"1.78","vib_list":[]}],"id":{"product":"6d91322ca9b048648de88ccf34f795c6","version":"a12b1ac5a11042a1a70089b0c696429a"},"installation":{"command":"CP035193.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>アップデートを有効にするために電源再投入/コールドリブートがインストール後に必要です。</u></p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン (</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用します<strong>)：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HP Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"VMware ESXi版在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 구성요소 - HPE 익스프레스 베이 인에이블먼트 스위치 카드"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPE Express Bay Enablement Switchカード"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-04-02T16:46:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Corrected the&nbsp;temperature status of Seagate NVMe hard drives.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added VMware vSphere 6.7 OS support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4439455","datemodified":"2021-01-28T10:26:04","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"766c141dc9dee9584178e8370e3175c3","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-28T10:15:05","revision":"0","sha1sum":"b327b9ef61c4c5fb3b2eef5b0cf28320ac1e14e8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"eb66fafd28ff4c39a42b91395104bd05","version":"37612bf05574410e82a1d995f4c5da94"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Driver&nbsp;of SuSE Linux Entherprise Server 15 Service Pack&nbsp;2 version 10.01.00.64.15.2-k1b</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."},{"lang":"ja","x_late":"このコンポーネントは、メザニンコンバージドネットワークアダプターのオペレーティングファームウェアをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"35625778","datemodified":"2020-11-19T06:22:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/CP042238.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/brcmflashStandalone-linux-12.0.1336.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/firmware/oc14-12.0.1336.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.02.01-1.6/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP042238.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP042238.scexe"],"md5sum":"296b8b4bedecbfc11f96b1060017a4d8","name":"firmware-cna-mezz-emulex-2021.02.01-1.6.x86_64.rpm","release":"2020-11-19T00:00:00","revision":"2","sha1sum":"c5e258f1a5e9930a0b6d55ec1e8e68cf38c026de","size":"33MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"e408d6e3ab3141509209d893c046e5e7","version":"63f19969a25e4c5b99e007aa57f4599f"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"},{"lang":"ja","x_late":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br />\n <br />\n 1. ファームウェアインストレーションツール：rpm -Uhv <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64-bitシステム） </p>\n\n<p> 2. 使用するシステムの適切な場所へcd し、./.setupを実行してファームウェアをアップデートします<br />\n <br />\n ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Linux (x64)"},{"lang":"ja","x_late":"HPE Bladeファームウェアフラッシュfor Emulexメザニンコンバージドネットワークアダプターfor Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-07T11:22:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"<p dir=\"LTR\">Fixed the following:</p>\n\n<ul>\n\t<li>Fixed a behavior with internal engineering data displays</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3281","Version":"1280A3"},{"DeviceName":"HPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3282","Version":"1280A3"},{"DeviceName":"HPE SN1000E 16Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E4","Version":"12.8.352.12"},{"DeviceName":"HPE SN1000E 16Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E5","Version":"12.8.352.12"},{"DeviceName":"HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197F","Version":"12.8.352.12"},{"DeviceName":"HPE  SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197E","Version":"12.8.352.12"},{"DeviceName":"HPE 84E 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C2238","Version":"1280A3"},{"DeviceName":"HPE SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200159000FB","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"10562150","datemodified":"2021-01-29T06:00:51","file_list":["/CP044728_BUILD_14.data","/CP044728.vmexe","/CP044728.vmexe64","/CP044728.vmfile","/CP044728_VMw.zip","/CP044728.xml","/payload.json","/CP044728_VMw.zip/index.xml","/CP044728_VMw.zip/vendor-index.xml","/CP044728_VMw.zip/metadata.zip","/CP044728_VMw.zip/vib20/CP044728/HPE_bootbank_CP044728_2021.02.01.14-6.5.0.4240417.vib","/CP044728_VMw.zip/metadata.zip/vendor-index.xml","/CP044728_VMw.zip/metadata.zip/vmware.xml","/CP044728_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044728_2021.02.01.14-6.5.0.4240417.xml","/CP044728_VMw.zip/metadata.zip/vibs/CP044728-4316729280172260162.xml"],"md5sum":"e0881057c9f05eb3adcf96aa874ce7b2","name":"CP044728.zip","release":"2021-01-29T05:57:10","revision":"0","sha1sum":"55546ff332d9efb5c054a1fd0aab7ef98c3d5890","size":"10MB","target_guids":["a6b1a447-382a-5a4f-10DF-F100103C3281","a6b1a447-382a-5a4f-10DF-F100103C3282","a6b1a447-382a-5a4f-10DF-E200103C17E4","a6b1a447-382a-5a4f-10DF-E200103C17E5","a6b1a447-382a-5a4f-10DF-E200103C197F","a6b1a447-382a-5a4f-10DF-E200103C197E","a6b1a447-382a-5a4f-10DF-F100103C2238","a6b1a447-382a-5a4f-10DF-E200159000FB","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D6","a6b1a447-382a-5a4f-10DF-F400159002D5"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044728","version":"2021.02.01.14-6.5.0.4240417"}]}],"id":{"product":"89d9be7c134e4e5d9700073722a0ffab","version":"14c85f7ab1b349818d323a06cf70f9c8"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.5"},{"lang":"ja","x_late":"Emulexファイバーチャネルホストバスアダプター for VMware vSphere 6.5用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp; have separate components to update fibre channel and converged network adapters.&nbsp;This is a fibre channel&nbsp;update component.</p>\n\n<p><strong>Contains:</strong></p>\n\n<p>32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16/32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>8 Gb HBA Standup firmware 2.10X6<br />\n8 Gb standup universal boot image 12.60a4(12.6.302.0 BIOS, 12.6.284.0 UEFI)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"218.0.166.0"},{"DeviceName":"Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"218.0.166.0"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 218.0.166.0 with the following firmware versions:</p>\n\n<ul>\n\t<li>Bootcode Version: 218.0.152.0</li>\n\t<li>NCSI Version: 218.0.125.0</li>\n\t<li>MBA Version:&nbsp;218.0.29.0</li>\n\t<li>UEFI Version:&nbsp;218.0.64.0</li>\n\t<li>CCM Version:&nbsp;218.0.19.0</li>\n\t<li>RoCE Version:&nbsp;218.0.5.0</li>\n</ul>\n"}],"files":[{"bytes":"7037001","datemodified":"2021-01-21T06:46:47","file_list":["bcm218.0.166.0.pup.HPb","bcm218.0.166.0.pup.xml","payload.json"],"md5sum":"fbf9af43979333128501969d0a6d8798","name":"bcm218.0.166.0.pup.fwpkg","release":"2021-01-21T06:40:05","revision":"0","sha1sum":"89f1dc924ea177bb2cee0464a1da1b1cc8584ef5","size":"6MB","target_guids":["a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16d614e41595"],"type_of_change":"1","version":"218.0.166.0"}],"id":{"product":"5fcadb289d2a4581aa347222e1e2d7d1","version":"80a5a3c49744434ead633b3163150833"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom Firmware Package for BCM5741x adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41596","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial version</li>\n\t<li>This product brings the support of Data Center Interconnect on supported devices.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n\t<li>This product addresses an issue about failing to detect firmware version while updating that under operation system.</li>\n\t<li>This product addresses an issue about connection lost under pre-OS environment after restart the system from OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"BCM_NXE_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2012 R2用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"905896","datemodified":"2020-06-12T07:09:59","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044560.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"6ce9db856b1883f680f1c0920815a62c","name":"cp044560.exe","release":"2020-06-12T06:56:07","revision":"0","sha1sum":"505dc1b5af7bb4b6589b7cf89e3977449f7b9bd6","size":"884KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"273329c7dcda48fbb886f52e82f63064","version":"1f9a78a521804f5081b7834970c35cd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG001800JWFVC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16154640","datemodified":"2021-01-27T12:08:43","file_list":["/CP045608_BUILD_3.data","/CP045608.vmexe","/CP045608.vmexe64","/CP045608.vmfile","/CP045608_VMw.zip","/CP045608.xml","/payload.json","/CP045608_VMw.zip/index.xml","/CP045608_VMw.zip/vendor-index.xml","/CP045608_VMw.zip/metadata.zip","/CP045608_VMw.zip/vib20/CP045608/HPE_bootbank_CP045608_HPD3.3-7.0.0.15843807.vib","/CP045608_VMw.zip/metadata.zip/vendor-index.xml","/CP045608_VMw.zip/metadata.zip/vmware.xml","/CP045608_VMw.zip/metadata.zip/vibs/CP045608-5345265126831946007.xml","/CP045608_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045608_HPD3.3-7.0.0.15843807.xml"],"md5sum":"b485df0593fab60897eadfc92eb34802","name":"CP045608.zip","release":"2021-01-27T12:06:04","revision":"0","sha1sum":"6d9ec0836c54eb63e83992cb0da1cdb35bd86afe","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045608","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"f651d51d32bf48dca96b23a2b4fb67f4","version":"7132662dcbc44b749ff8f1dff0da7b60"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG001800JWFVC ライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:14:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.16.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.16"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3928135","datemodified":"2020-10-15T06:59:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/CP042957.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/UBM2_V1.16.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP042957.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP042957.scexe"],"md5sum":"cce6925055c5240f187a44a2ac3514fd","name":"firmware-smartarray-40023de47f-1.16-1.1.x86_64.rpm","release":"2020-10-15T06:41:04","revision":"0","sha1sum":"1b095c7e9c57026b8221e58fedb31b62c73d6993","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.16"}],"id":{"product":"baaff1c67f3f496a9b2cb59a73843db0","version":"e09e6de6ed4946ebb3c232cfddf903a4"},"installation":{"command":"CP042957.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP042957.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-40023de47f-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP042957.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-smartarray-40023de47f-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM2 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-02-22T06:22:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM4_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3943406","datemodified":"2021-01-21T13:32:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/CP043314.xml","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/UBM4_V1.20.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-b368ad032e-1.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043314.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043314.scexe"],"md5sum":"64ba97460fbe3980198e2cb35e44e1cc","name":"firmware-b368ad032e-1.20-1.1.x86_64.rpm","release":"2021-01-21T13:15:08","revision":"0","sha1sum":"ce51fe437520e2a675f1ad1bf7da2af8b3efcccd","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.20"}],"id":{"product":"a6b537d158284bcb8d8b5bf0c949d656","version":"a34871f8c7de4bd7a987625a898740ef"},"installation":{"command":"CP043314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP043314.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-b368ad032e-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP043314.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-b368ad032e-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-b368ad032e-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-b368ad032e-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM4 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-28T14:26:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048992af248","Version":"3H5Q"},{"DeviceName":"MZXL51T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-364889da9feb","Version":"3H5Q"},{"DeviceName":"MZXL53T2HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-3248cfd7fef8","Version":"3H5Q"},{"DeviceName":"MZXL56T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-3448c531f122","Version":"3H5Q"},{"DeviceName":"MZXL512THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-54488858a5c5","Version":"3H5Q"},{"DeviceName":"MZXL5960HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-3048d9dd07de","Version":"3H5Q"},{"DeviceName":"MZXL51T9HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-39483a8fb090","Version":"3H5Q"},{"DeviceName":"MZXL53T8HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38488ed832eb","Version":"3H5Q"},{"DeviceName":"MZXL57T6HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-36489d1db6a9","Version":"3H5Q"},{"DeviceName":"MZXL515THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-544832bf723c","Version":"3H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs: VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07 Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37 Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp; </strong>3H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"7683072","datemodified":"2021-01-23T12:16:42","file_list":["cp046693.xml","cpqsetup.exe","MPK73H5Q.REL","payload.json","setup.dll"],"md5sum":"18c91e151adb879d58a58ed20182a6ec","name":"cp046693.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"3b7c8c318034fe1b12d4c533595b0d3dbf0d42da","size":"7MB","target_guids":["4d2340a5-585a-354c-3830-3048992af248","4d2340a5-585a-354c-3154-364889da9feb","4d2340a5-585a-354c-3354-3248cfd7fef8","4d2340a5-585a-354c-3654-3448c531f122","4d2340a5-585a-354c-3132-54488858a5c5","4d2340a5-585a-354c-3936-3048d9dd07de","4d2340a5-585a-354c-3154-39483a8fb090","4d2340a5-585a-354c-3354-38488ed832eb","4d2340a5-585a-354c-3754-36489d1db6a9","4d2340a5-585a-354c-3135-544832bf723c"],"type_of_change":"1","version":"3H5Q"}],"id":{"product":"459b31cbafbe408eaf0a96421248c984","version":"87d7e834163f44059d0fbb819c4021bb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T07:38:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Working version MPK73H5Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL53T2HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL512THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEPA and MB4000JFEPB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB2000JFEPAおよびMB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n      HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>    <br />\n      None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3611912","datemodified":"2020-12-16T18:52:16","file_list":["cp045543.xml","cpqsetup.exe","payload.json","setup.dll","SMKRAND5.rel"],"md5sum":"12f173f5df75bc6ce3ffe3779c58a1db","name":"cp045543.exe","release":"2020-12-16T18:39:10","revision":"0","sha1sum":"38759d6ff7dbb3f647770f7ea3efe2d6aca6dae3","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8fa907efc8b04d69b552ce8d557c6113","version":"d99af2893f80438a8fa7d07a5ec6d2c8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:47:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS&nbsp;</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.00(B)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>Microsoft Windows Server 2019 OSのサポートを追加しました </li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点：</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"3554896","datemodified":"2018-09-25T13:54:13","file_list":["cp037609.xml","cpqsetup.exe","payload.json","setup.dll","TiogaPass-Release-1.00-build-000.bin.fw"],"md5sum":"db7598d0a4acd50e66893097e9fad4aa","name":"cp037609.exe","release":"2018-10-23T00:00:00","revision":"1","sha1sum":"e8b8f7972272cffd91a426073f4f1849b43863bb","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00"}],"id":{"product":"b6b93bd958d94fa882426d0e7804a97a","version":"1556330b16d84d5b9b2ca0146ae38ea9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 2000  Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-04T14:11:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.78-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.78"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.78-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.78"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.78 (A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.50(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;&nbsp;Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5679728","datemodified":"2019-01-24T07:31:19","file_list":["cp038812.xml","cpqsetup.exe","flash_Exp_1.00.bat","payload.json","setup.bat","setup.dll","storcli64.exe","Tiburon-Release-1.78-build-000.bin"],"md5sum":"adf124e8c272edf35e5b5fa9cc832ddd","name":"cp038812.exe","release":"2019-01-24T13:22:04","revision":"0","sha1sum":"1254d01a308a02c7d6ae7a7f2c73aef2f1826c03","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"0","version":"1.78"}],"id":{"product":"ecd80496db274bbda7c43a5153ea6bdf","version":"1ea77270381842cf9afaf553085e2b85"},"installation":{"command":"setup.bat","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.03またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 4200バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-02-23T09:52:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for the HPE Apollo 4200 Gen10 Server</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3154664","datemodified":"2020-12-16T13:12:39","file_list":["4IYRHPG6.bin","cp045898.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"f6cec1a69a68757ea1d34562f193e884","name":"cp045898.exe","release":"2020-12-16T13:04:12","revision":"0","sha1sum":"5c3f59e1954faf0212937471d1e80bcf615f11f1","size":"3MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"4ec88340a2ce4a0da239c4051a775bd6","version":"999c3f7705f243f59baf7e0c41c0f3bb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T05:12:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>HPG6 introduces bug fixes, reliability enhancement and modification in SMART Attributes. Once HPG6 is downloaded, the drive cannot be changed back to an earlier firmware (eg, HPG3).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1230032","datemodified":"2021-01-14T07:44:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"41e355e8d3c84b3255ceef5737a6ffef","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"7fc9eff00e5853ddd7706d1f9bda348745a7bef5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1265721","datemodified":"2021-01-14T07:37:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"b3b83ef2621c73df7709acc7b11c91ad","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"9400144fadc091f44fbc6b9e2738f3130fc5c6f4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"da2886f50e85443fa3f87dcf733edc2b","version":"74cd88bdfbf54bf5bd8c1cc53129ec38"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 SP4."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP4で動作するBlade QLogic NX2マルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic NX2 Linux userspace IO daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"101623","datemodified":"2020-02-12T18:44:05","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/9bf372a41890ef478f1db32788dcc570a8164b","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"1ed6aab3f2ce508404bc310527414602","name":"iscsiuio_bl-2.11.5.13-3.sles12sp4.x86_64.rpm","release":"2020-02-12T18:43:03","revision":"0","sha1sum":"d24704b01ab3f148b1d2d45b4ad5ae9dd930ee04","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"9c1bf13a249f407385b64aced1372b42","version":"bce85f0f5df0438bb89ca0809299c4fe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP4"},{"lang":"ja","x_late":"HPE Blade QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP4"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI BFS failure with VLAN.</p>\n\n<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n\n<p>This product addresses an issue where&nbsp;an iSCSI portal is&nbsp;discovered with invalid an VLAN ID.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Insight Management WBEM Providers supply system management data through the Windows Management Instrumentation framework for HPE ProLiant Gen8/Gen9 server platforms and options. The Insight Providers offer industry standard DMTF SMASH profile and SNIA SMI-S profile compliance."},{"lang":"ja","x_late":"HPE Insight Management WBEM Providerは、HPE ProLiant Gen8/Gen9サーバープラットフォームおよびオプション用のWindows Management Instrumentationフレームワークを介してシステム管理データを提供します。Insight Providersは業界標準のDMTF SMASH プロファイルとSNIA SMI-Sプロファイルのコンプライアンスを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"29268016","datemodified":"2020-11-26T12:26:20","file_list":["cp045863.xml","cpqsetup.exe","cp_data.xml","depcheck.dll","hpwbemproviders_x64.msi","hpwmi_cfg.en","hpwmi_cfg.ja","hpwmi_cfg_en.xml","hpwmi_cfg_ja.xml","install.xml","multisetup.dll","mu_visual_cpp_2015_redistributable_update_3_x64_9052538.exe","vc110rtl-x64-release.msi"],"md5sum":"a6760b5bf1f4818579dc542960364bd4","name":"cp045863.exe","release":"2021-04-22T00:00:00","revision":"2","sha1sum":"d7212640c4672686f1c3930bcb9649fcb605d338","size":"27MB","target_guids":[],"type_of_change":"0","version":"11.0.0.0"}],"id":{"product":"5a5d111ea5d342d3a23a115f7e130493","version":"13fcd40ea16344a7a369dc9c62b78116"},"installation":{"command":"cpqsetup.exe","command_params":"/optional /verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb0c60beb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Advanced System Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fd28bc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Advanced System Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec156d1f28","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO Advanced and Enhanced System Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3 Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1c3859d4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3 Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant 100-Series Management Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eceeceee78","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant 100-Series Management Controller Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2c83f673","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9ecb0f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP System Management Homepage for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1b3359b0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP System Management Homepage for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant PCI Hot Plug Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca134477","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant PCI Hot Plug Controller Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d6a8690","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Board Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec043b810e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Rack Infrastructure Interface Service for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3c85d0a3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Rack Infrastructure Interface Service for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC31xx Fast Ethernet NIC Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec0458ccd6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC31xx Fast Ethernet NIC Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec29a79e49","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec83d2dd89","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8b37898c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec82a27969","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc2ac73ef","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7bc999f9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6e1a64e9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec86615221","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec09e99f10","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe73cc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec76564025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec431d2047","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbbd7533a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008 x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd765f4f8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Multifunction Driver for Windows Server 2003/2008 x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec99544f42","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec10a1b876","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf2c2c1fe","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca203699c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9814091f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec013cb3c5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4efaf7b6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecba1ae635","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<ol>\n\t<li>Place the Smart Component in a temporary directory, then double-click it to run.</li>\n\t<li>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</li>\n\t<li>Click the &quot;Install&quot; button to perform the installation.</li>\n</ol>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<ol>\n\t<li>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</li>\n\t<li>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</li>\n\t<li>[インストール]ボタンをクリックしてインストールを実行します。</li>\n</ol>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Insight Management WBEM Providers for Microsoft Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-05-28T08:19:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Server provider\n\t<ul>\n\t\t<li>Fixed product dependency issue</li>\n\t\t<li>Rebrand help information</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed issue that allowed installation on unsupported products incorrectly</li>\n\t<li>Modified help information to comply with de-branding requirements</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"SPP","value":"HPE Service Pack for ProLiant"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpwmiver.dll","sw_key_expectedpath":"%ProgramFiles%\\hpwbem"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596441","datemodified":"2021-01-26T22:20:02","file_list":["I41_2.42_01_23_2021.signed.flash","I41_2.42_01_23_2021.xml","payload.json"],"md5sum":"cbf53cddc70be6024173cc442816be30","name":"I41_2.42_01_23_2021.fwpkg","release":"2021-01-26T22:15:04","revision":"0","sha1sum":"2959cc9cc3a7e344cb6bcdecfa4f214416ebedc5","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"65d759aa54bf415a9a190ccfb152d004","version":"3097b762d1404df3a7b0dc2d238f94fd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant BL460c Gen10 (I41) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T22:29:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG2"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG2"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG2"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3837176","datemodified":"2021-01-05T08:32:28","file_list":["cp046508.xml","cpqsetup.exe","K401HPG2.rel","payload.json","setup.dll"],"md5sum":"c667bcc271133ae001342070db7f4eaf","name":"cp046508.exe","release":"2021-01-05T08:18:05","revision":"0","sha1sum":"6f3452b044f44fc2a90627c85cefee75a1bdf3dd","size":"3MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"0","version":"HPG2"}],"id":{"product":"8e8fd25144334177930f2db95d492320","version":"0e32155de80a4c609ea573f45309a87f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-05T08:14:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4667635","datemodified":"2020-06-03T19:27:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/CP043984.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043984.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043984.scexe"],"md5sum":"e608be91a0e03c74603fd8b7736e7974","name":"firmware-hdd-2a5b65f157-HPK4-5.1.x86_64.rpm","release":"2020-06-03T19:18:07","revision":"0","sha1sum":"8e00648a7fcff5b671ce258befc4866c035358be","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"74b89b05406c4068843f3b27148a33d9","version":"0860ece1489c420c911b9ff24878b641"},"installation":{"command":"CP040087.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-08T14:51:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SLES15SP1.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, LSI_SAS2, provides Windows Server 2016 support for HPE H2xx SAS/SATA Host Bus Adapter. "},{"lang":"ja","x_late":"このLSI_SAS2ドライバーは、HPEドライバーH2xx SAS/SATAホストバスアダプター対応のWindows Server 2016サポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1513232","datemodified":"2018-09-28T00:45:55","file_list":["cp037731.xml","cpqsetup.exe","driverconfigparam.def","generic.dll","install.xml","lsinodrv.inf","lsi_sas2.cat","lsi_sas2.inf","lsi_sas2.pdb","lsi_sas2.sys","lsi_sas2_win10_vNext.txt","user guide - windows driver configuration utility.pdf","wdcfg.exe"],"md5sum":"ad9ca644816eb28c67640637713c912f","name":"cp037731.exe","release":"2018-09-28T05:45:03","revision":"0","sha1sum":"6757abdfed6a1a6de3cd854b3cf7d9ac1b51e0fc","size":"1MB","target_guids":[],"type_of_change":"0","version":"2.68.64.2"}],"id":{"product":"8d193d8d218443f6b0fa9476dd4e1562","version":"bb7e74123df640a0a8d37e579daf5ada"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for 64-bit Microsoft Windows Server 2016 Editions"},{"lang":"ja","x_late":"HPE H2xx SAS/SATAホストバスアダプタードライバーfor 64-bit Microsoft Windows Server 2016 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-28T05:19:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2.68.64.2(B)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If component version 2.68.64.2(A) was previously installed, then it is not necessary to upgrade to version 2.68.64.2(B).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Enhancements/New Features implemented in version 2.68.64.2(A)</strong>:</p>\n\n<p style=\"margin-left:.2in\">Added support for:</p>\n\n<ul>\n\t<li>Microsoft Windows Server 2016 - Server Core and Server with a Desktop.</li>\n\t<li>Revised component package. No change to driver functionality resulting from the change. If system has previously updated to driver version 2.68.64.2, then it is not necessary to update to 2.68.64.2(A).</li>\n</ul>\n\n<p style=\"margin-left:1.0in\">&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"lsi_sas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.40 (02/24/2021)"},{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022e","Version":"v2.40 (02/24/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33579471","datemodified":"2021-02-25T15:57:15","file_list":["A48_2.40_02_24_2021.signed.flash","A48_2.40_02_24_2021.xml","payload.json"],"md5sum":"936854bc0a492bcdcab6bb2ed43fdf33","name":"A48_2.40_02_24_2021.fwpkg","release":"2021-02-25T15:54:04","revision":"0","sha1sum":"cb3820158923bb9ddf362939ad2725915baa7738","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f","00000000-0000-0000-0000-00000000022e"],"type_of_change":"0","version":"2.40_02-24-2021"}],"id":{"product":"c91a34b258694c1696514c7b51041b33","version":"f8efeb05689044f18bf17bae724720cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-30T19:50:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"69916","datemodified":"2021-02-09T13:38:46","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"19f53eb462e039cd64174e6bbba4abc7","name":"smartpqi-kmp-default-2.1.8-040.sles15sp1.x86_64.rpm","release":"2021-02-09T13:31:28","revision":"0","sha1sum":"2c481b42b87e554c4c36c142dbf73eff19d77c97","size":"68KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.8-040"},{"bytes":"70567","datemodified":"2021-02-09T13:37:26","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"ef9c94c45eca6ad5ee5fb7d5fb276dc3","name":"smartpqi-kmp-default-2.1.8-040.sles15sp2.x86_64.rpm","release":"2021-02-09T13:31:28","revision":"0","sha1sum":"130cf05bf873577320a831da349e34ac5ba71c8a","size":"68KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.8-040"}],"id":{"product":"ddc8bdca3abc4ab8823e820be1ed4dfd","version":"420f1982e4764656a700ea3065dd47b8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>To add an enhancement to fix the stale Drive fi&nbsp;rm&nbsp;ware version returned by a Power Shell command.&nbsp;</p>\n","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This release provides the following fixes:&nbsp;</p>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the system hangs when resuming from hibernation.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue&nbsp;where the enclosure identifier field corresponding to the physical devices became empty in&nbsp;lsscsi/sysfs&nbsp;during device rescan.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue to display topology using PHY numbers&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver did not export valid SAS&nbsp;initiator_port_protocols&nbsp;and&nbsp;target_port_protocols&nbsp;to&nbsp;sysfs.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the driver would cause a kernel panic if it got an invalid response from the controller.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where the LUN reset, system shutdown, system suspend, system hibernate, controller offline, and I/O requests could reach the controller when they are not required.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where after modifying the logical volume size,&nbsp;lsblk&nbsp;command still shows up previous size of logical volume.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue where during the device discovery, the driver issued an INQUIRY to physical devices, and these requests could get lost due to broken devices, loss of signal issues, etc. This would cause device discovery to get hung.&nbsp;</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>-</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"3.53"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"3.53"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"3.53"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408e-m、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi - HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; 3.53</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 3.21<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;</p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n    3.53</p>\n\n<p><strong>最新の推奨またはクリティカルバージョン：</strong><br />\n    3.21<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     なし<br />\n<br />\n<strong>ファームウェアの依存関係:</strong><br />\n     なし</p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>UBMタイプ3バックプレーンのサポートを追加しました</li>\n\t<li>SATAドライブの長いデバイスモデル/製品IDのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong>     </p>\n\n<p>     </p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">定期的なI/Oの受信中にコントローラーが応答しなくなる可能性がある問題。</li>\n\t<li style=\"list-style-type: disc;\">エキスパンダーの構成中にファームウェアがデバイスを検出しようとし続けるため、ホストI/Oのタイムアウトが発生する可能性があります。</li>\n\t<li style=\"list-style-type: disc;\">サポートされていないブロックサイズの不良ドライブを使用すると、コントローラーのロックアップ問題（コード0x1E10）が発生することがあります。</li>\n\t<li style=\"list-style-type: disc;\">複数のホットプラグおよびホットリムーブイベント（ドライブまたはJBOD）が処理されているときに、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">コントローラーが、フラッシュバックライトキャッシュを有効にした論理ドライブを、論理ドライブの最後に向かってシーケンシャルリードでハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">I/Oが未処理の物理ドライブをホットプラグすると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストI/Oおよびバックグラウンド整合性チェックで、すべてのドライブに同じLBA上でUREが発生しているRAID-1 ADMストライプが同時に検出されると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストがコントローラー構成の消去コマンドまたはその他の構成変更コマンドを発行したときに、RAID6/60論理ドライブのドライブに障害が発生すると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">SSDデータドライブは、スペアの再構築が進行しているときにホットリムーブして再挿入すると、オフラインに設定される場合があります（理由コード0x37）。</li>\n\t<li style=\"list-style-type: disc;\">サニタイズ消去が終了した直後にシステムを再起動すると、ドライブがOSに公開されない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">12Gb SAS Expander Cardの特定のポート（ポート7以上）にUBMバックプレーンを接続すると、UBMバックプレーンが正しく検出されません。</li>\n\t<li style=\"list-style-type: disc;\">アイドル状態の後に短時間のI/Oを行うと、コントローラーがハングアップすることがあります。</li>\n\t<li style=\"list-style-type: disc;\">SATAドライブのドライブファームウェアのアップデート後に、コントローラーが以前のドライブファームウェアバージョンを返す場合があります。</li>\n\t<li style=\"list-style-type: disc;\">マルチエキスパンダーエンクロージャー構成でのエキスパンダーファームウェアのアップグレード中に、コントローラーがドライブを障害と見なす可能性があります（理由コード0x49、I/Oフリーズタイムアウトで）。</li>\n\t<li style=\"list-style-type: disc;\">特定のファンアウトエキスパンダータイプの外部エンクロージャーモデルで、ホットアドされたドライブのLED制御が失敗します。</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essentialシリーズコントローラーは、シーケンシャルI/Oを処理しているときに応答せず、ファームウェア合体ロジックがメモリを取得できない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">SmartCache構成でプライマリ論理ドライブへの断続的な書き込みI/Oエラーが発生すると、ファイルシステムまたはアプリケーションが古いデータを読み取る可能性があります。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong></p>\n\n<p>     なし\n        </p>\n"}],"files":[{"bytes":"22234445","datemodified":"2021-02-16T13:41:00","file_list":["/CP046359_BUILD_10.data","/CP046359.vmexe","/CP046359.vmexe64","/CP046359.vmfile","/CP046359_VMw.zip","/CP046359.xml","/payload.json","/CP046359_VMw.zip/index.xml","/CP046359_VMw.zip/vendor-index.xml","/CP046359_VMw.zip/metadata.zip","/CP046359_VMw.zip/vib20/CP046359/HPE_bootbank_CP046359_3.53.10-7.0.0.15843807.vib","/CP046359_VMw.zip/metadata.zip/vendor-index.xml","/CP046359_VMw.zip/metadata.zip/vmware.xml","/CP046359_VMw.zip/metadata.zip/vibs/CP046359-3193037604949208488.xml","/CP046359_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046359_3.53.10-7.0.0.15843807.xml"],"md5sum":"aba22133c137e86df5d82f0c304ea4e8","name":"CP046359.zip","release":"2021-03-22T00:00:00","revision":"1","sha1sum":"4f2f2b4413e2cc1f8e297ef0ac7783439b98ef8e","size":"21MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"3.53","vib_list":[{"name":"CP046359","version":"3.53.10-7.0.0.15843807"}]}],"id":{"product":"4f319faf890642fc80a3d8719760c121","version":"65c6754b2f33461bacd59f7bfa851024"},"installation":{"command":"CP046359.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-29T13:00:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while waiting for a non-existent pre-fetch queue entry.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with an unsupported block size is connected into slot 0.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue on DDR caching enabled logical volumes with sequential read towards the end of the volume.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue with outstanding I/Os on a degraded logical volume when the physical drive fails.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS after reboot if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in an expander card configuration.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when processing idle time followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MK0960GECQK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4586243","datemodified":"2020-12-13T14:36:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/CP045450.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/GSV843G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045450.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045450.scexe"],"md5sum":"9a811bdfb717139b84bab104ba09ebcf","name":"firmware-hdd-3e34285be7-HPG3-10.1.x86_64.rpm","release":"2020-12-13T14:23:08","revision":"0","sha1sum":"91150a55230509fd9d45ce49c842dd4381d4b255","size":"4MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"63eaf8b9f2d74ded922cd74f7d530631","version":"2e9859e8a35d46ffa7bcf7db45a1d8ae"},"installation":{"command":"CP040262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK0960GECQK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides and installs an updated version of firmware for the iLO 4 Management Processor allowing for continued management support of your Server."},{"lang":"ja","x_late":"このコンポーネントは、iLO 4マネジメント プロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br/>\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br/>\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"13956560","datemodified":"2020-12-09T13:07:55","file_list":["SignedImageInstaller64.dll","cp046022.xml","cpqsetup.exe","cpqsysio64.sys","ilo4_277.bin","readme.txt"],"md5sum":"62df4e10020ae49171a3ee05984b1245","name":"cp046022.exe","release":"2020-12-17T00:00:00","revision":"1","sha1sum":"5ac6da04514965d8ebfa27b84eda1fd9ab15db80","size":"13MB","target_guids":[],"type_of_change":"2","version":"2.77"}],"id":{"product":"2137f29484a3411eb23b24a938438e8b","version":"95eea41a7a4544fdadae05b571b11307"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Install the firmware using one of these options:</strong></p>\n\n<ul>\n\t<li>Run the Component on the host to be updated.<br />\n\tThe component will update the iLO&nbsp;4 firmware and reset the iLO&nbsp;4 processor.<br />\n\t&nbsp;</li>\n\t<li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO4_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:\n\t<ul>\n\t\t<li>Login to iLO 4, navigate to the Update Firmware page, and update the firmware from there.</li>\n\t\t<li>Use the HPE Lights-Out Configuration Utility, CPQLOCFG, and RIBCL/XML scripts to update iLO&nbsp;4 across the network.</li>\n\t\t<li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO&nbsp;4 from the supported host OS.</li>\n\t\t<li>Use the Directory Migration Utility, contained in the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_573a541eab8c439db63dc4d3be#\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>Upgrade Requirement:&nbsp;Lowering the severity of the upgrade requirement to Recommended as per the HPE Product Security Policy. It is based on the CVE score for this security vulnerability (7.3), assessment of the impact and the probability of occurrence. So upgrade requirement has been revised to &lsquo;Recommended&rsquo; upgrade.</p>\n"},{"lang":"ja","x_late":"<p><strong>以下のいずれかのオプションを使用してファームウェアをインストールしてください。</strong></p>\n\n<ul>\n\t<li>アップデートするホスト上のコンポーネントを実行します。<br />\n\tこのコンポーネントは、iLO 4ファームウェアをアップデートし、iLO 4プロセッサーをリセットします。<br />\n\t </li>\n\t<li>コンポーネントからファームウェアを抽出します。  これにより、iLO4_yyy.bin (yyyはファームウェアバージョン)がターゲットディレクトリにコピーされます。  以下のオプションがあります。\n\t<ul>\n\t\t<li>iLO 4にログインし、アップデートファームウェアページに移動して、ファームウェアをアップデートします。</li>\n\t\t<li>ネットワーク経由でiLO 4をアップデートするには、HPE Lights-Out構成ユーティリティ、CPQLOCFG、およびRIBCL/XMLスクリプトを使用します。</li>\n\t\t<li>サポートされるホストOSからiLO 4をアップデートするには、HPEオンラインLights-Out構成ユーティリティ、HPONCFG、およびRIBCL/XMLスクリプトを使用します。</li>\n\t\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_573a541eab8c439db63dc4d3be#\">HPE Directories support for Management Processors</a>に含まれているDirectory Migrationユーティリティを使用します。このWindowsユーティリティでは、Lights-Outプロセッサーのネットワーク検出、インポート/エクスポート機能、およびバルクファームウェアアップデートをサポートしており、ディレクトリの移行は不要です。</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>アップグレード要件：HPE製品セキュリティポリシーに従って、アップグレード要件の深刻度を推奨に下げます。これは、このセキュリティの脆弱性のCVEスコア（7.3）、影響の評価、および発生の可能性に基づいています。そのため、アップグレード要件が‘推奨’アップグレードに改訂されました。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Vista (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"edition":"bus","major":"6","minor":"0","name":"Microsoft Windows Vista Business (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"edition":"ent","major":"6","minor":"0","name":"Microsoft Windows Vista Enterprise (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"5","minor":"1","name":"Microsoft Windows XP 64-Bit Edition","platform":"NT64","sr":"OEM"},{"major":"5","minor":"2","name":"Microsoft Windows XP Professional x64 Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-03T08:49:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to display login banner SSH login</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Potential vulnerabilities in network stack. Click <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=hpesbhf04070en_us\">here</a> to know more about the Security Vulnerabilities.</li>\n\t<li>Active directory test may fail during LDAP authentication.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support to display login banner SSH login</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Potential vulnerabilities in network stack. Click <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=hpesbhf04070en_us\">here</a> to know more about the Security Vulnerabilities.</li>\n\t<li>Active directory test may fail during LDAP authentication.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"lang":"ja","x_late":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"589880","datemodified":"2021-01-21T05:51:28","file_list":["cp046492.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"md5sum":"8c65876570a32961c1bfc134e3acda07","name":"cp046492.exe","release":"2021-04-23T00:00:00","revision":"1","sha1sum":"1ea78a237a99feea3ef295cbc1b330f907abc985","size":"576KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"95e1a7b8a2664cd8b8d67128eff9bb87","version":"b36691c8cd494de6b7208672ada2fa4c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-28T10:27:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed branding issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nechesasr.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"752437","datemodified":"2021-03-22T15:59:06","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"7179d851c11aa84ce7f74c758a02eccd","name":"hp-ams-2.10.2-876.11.rhel7.x86_64.rpm","release":"2021-03-22T15:51:09","revision":"0","sha1sum":"0303124e78c8d56fc632bc777ba409adff4f5ad5","size":"734KB","target_guids":[],"type_of_change":"0","version":"2.10.2"}],"id":{"product":"e574ba077b7e40e98fa10de501cd4f19","version":"2c58b8c0db4c45c1a31d76575ed74a4f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man&nbsp;amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器的 HPE ProLiant 無代理管理服務"},{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE ProLiant Agentless 관리 서비스"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE ProLiant无代理管理服务"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-07T12:16:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the Following Items:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added&nbsp;the warning message for users to restart hp-ams service when iLo reset more than twice. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099805en_us\" style=\"color:#0563c1; text-decoration:underline\">a00099805en_us</a>.&nbsp;&nbsp;</li>\n\t<li>When the server detects the physical network cable is plugged or unplugged, hp-ams will send out a trap to notify the administrator about the&nbsp;physical network status change.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15066344","datemodified":"2021-02-03T04:02:32","file_list":["/CP045147.vmexe64","/CP045147.vmfile","/CP045147.xml","/payload.json","/README.txt"],"md5sum":"3110381e4ad2f4f78a72944f540867b3","name":"CP045147.zip","release":"2021-02-03T04:08:05","revision":"0","sha1sum":"62d4dcaa30186001aa23e383944e664a0051cf6c","size":"14MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.1","vib_list":[]}],"id":{"product":"15d448815a234025a6958f5176b1dc77","version":"19e300a899134c03aa96a8302798a3d2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n\n<p>Note: In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.<br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000JWDFD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, only found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18281171","datemodified":"2021-01-28T11:52:01","file_list":["/CP045643_BUILD_3.data","/CP045643.vmexe","/CP045643.vmexe64","/CP045643.vmfile","/CP045643_VMw.zip","/CP045643.xml","/payload.json","/CP045643_VMw.zip/index.xml","/CP045643_VMw.zip/vendor-index.xml","/CP045643_VMw.zip/metadata.zip","/CP045643_VMw.zip/vib20/CP045643/HPE_bootbank_CP045643_HPD2.3-7.0.0.15843807.vib","/CP045643_VMw.zip/metadata.zip/vendor-index.xml","/CP045643_VMw.zip/metadata.zip/vmware.xml","/CP045643_VMw.zip/metadata.zip/vibs/CP045643--8899087658320210945.xml","/CP045643_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045643_HPD2.3-7.0.0.15843807.xml"],"md5sum":"a92d06213ae393bf68ecd5408a999087","name":"CP045643.zip","release":"2021-01-28T11:49:11","revision":"0","sha1sum":"304c0461b3091d0cb87398dcec52b13949ea7716","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"2","version":"HPD2","vib_list":[{"name":"CP045643","version":"HPD2.3-7.0.0.15843807"}]}],"id":{"product":"72ce2dc2a1214941a11d7ccaace19196","version":"79565131b5714c1bb5ef1c954bb990b6"},"installation":{"command":"CP040682.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:44:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing. Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing. Includes additional fixes to improve error handling and reliability.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2528424","datemodified":"2020-12-03T19:27:22","file_list":["QLAFWUpdate.exe","adapters.properties","cp044797.xml","cpqsetup.exe","hld60404.bin","installer.dll","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"13ea5ca0f87d82ac699bb23d3ec9d66d","name":"cp044797.exe","release":"2020-12-03T19:07:04","revision":"0","sha1sum":"89b8306814b1590920bee50a7f19bb2e0a7557d1","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"775df1f4997747b1b9988fc3c9990436","version":"e8a2ab89b4ca467b9787bf8aa3a783bd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Microsoft Windows Server 2012R2/2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb and 16 Gb&nbsp;products.</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td style=\"width:50px\">UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.03.00</td>\n\t\t\t<td>8.08.231</td>\n\t\t\t<td>7.02</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Address unexpected behavior when Fibre Channel adapters were simultaneously running traffic to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n\t<li>Fibre Channel adapter firmware versions were not showing up as expected in the AHS log.</li>\n\t<li>Port statistics counters would sometimes not update in the event of Loss of Signal or Loss of Sync</li>\n\t<li>link downs would occur during specific frame sequences used by the HPE XP8 array after array-side link loss</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"119799","datemodified":"2021-01-09T01:11:21","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb/igb.ko","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"67af83f18b815ad25eb748326e872ee8","name":"kmod-hp-igb-6.2.5-1.rhel8u3.x86_64.rpm","release":"2021-01-09T01:05:08","revision":"0","sha1sum":"f9d69c0ced19163ea7bee5f75bde68c485ff1675","size":"116KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.2.5-1"},{"bytes":"119889","datemodified":"2021-01-09T01:13:05","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-igb/igb.ko","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"4ee4240fa4801a8b01577313503ffb0f","name":"kmod-hp-igb-6.2.5-1.rhel8u2.x86_64.rpm","release":"2021-01-09T01:05:08","revision":"0","sha1sum":"dd196e28a198d68aab95d437a09ad3f3124ab0f1","size":"117KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.2.5-1"}],"id":{"product":"eb361011be5348dc81ccf25ec5c94210","version":"52022173ad2f44149b994b9926f7f040"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now support HPE Intel Online Firmware Upgrade Utility for Linux x86_64, version (or later) to update firmware</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"7648288","datemodified":"2021-02-16T00:05:41","file_list":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"md5sum":"05f74864eefa87fd2bd753f6a7648dac","name":"sut-2.8.0-26.linux.x86_64.rpm","release":"2021-02-16T05:57:04","revision":"0","sha1sum":"1dd8a18bba44878492a99688b73943055cc03b8b","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"type_of_change":"1","version":"2.8.0.0"}],"id":{"product":"b3a8e7e2c4ea466a9b404955f474449e","version":"015273f049214524a6bbf4ba7f7f45db"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Linux x64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T13:44:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sut","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27029920","datemodified":"2021-01-21T06:46:39","file_list":["/CP044970_BUILD_23.data","/CP044970.vmexe","/CP044970.vmexe64","/CP044970.vmfile","/CP044970_VMw.zip","/CP044970.xml","/payload.json","/CP044970_VMw.zip/index.xml","/CP044970_VMw.zip/vendor-index.xml","/CP044970_VMw.zip/metadata.zip","/CP044970_VMw.zip/vib20/CP044970/HPE_bootbank_CP044970_4.13.9.23-7.0.0.15843807.vib","/CP044970_VMw.zip/metadata.zip/vendor-index.xml","/CP044970_VMw.zip/metadata.zip/vmware.xml","/CP044970_VMw.zip/metadata.zip/vibs/CP044970--6209914235843924913.xml","/CP044970_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044970_4.13.9.23-7.0.0.15843807.xml"],"md5sum":"2a76ecdf36c575626ca1f4c6418be6fb","name":"CP044970.zip","release":"2021-01-21T06:44:05","revision":"0","sha1sum":"41ea873f835cfb8334e8035536719725aea7a3db","size":"25MB","target_guids":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"type_of_change":"0","version":"4.13.9","vib_list":[{"name":"CP044970","version":"4.13.9.23-7.0.0.15843807"}]}],"id":{"product":"fbba430fadcd437fa480e86bae79681f","version":"829c3c2d15a641eeba5aebd3a2d8464d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports firmware upgrade in the ESXi 7.0.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue of inconsistent LED behavior while linking up with different speed.</li>\n\t<li>This product corrects an issue about failing to restore the factory default value by pressing F7.</li>\n\t<li>This product addresses an issue where driver doesn&rsquo;t load upon booting up by correct memory relocation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supported NPAR enabling option.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product contains support PLDM firmware upgrade base improvements.</li>\n\t<li>This product addresses an overheat issue on the network adapters as below,</li>\n</ul>\n\n<p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />\nHPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_MARVELL_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30116","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30052","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 10/25GbE 2P SFP28 MCX512F, HPE 10/25GbE 2P SFP28 MCX562A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (P13188-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (P10112-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"37358135","datemodified":"2021-02-03T03:18:15","file_list":["/CP045142.vmexe64","/CP045142.vmfile","/CP045142_VMw.zip","/CP045142.xml","/payload.json","/README.txt","/CP045142_VMw.zip/index.xml","/CP045142_VMw.zip/vendor-index.xml","/CP045142_VMw.zip/metadata.zip","/CP045142_VMw.zip/vib20/CP045142/HPE_bootbank_CP045142_1.0.0-7.0.0.15525992.vib","/CP045142_VMw.zip/metadata.zip/vendor-index.xml","/CP045142_VMw.zip/metadata.zip/vmware.xml","/CP045142_VMw.zip/metadata.zip/vibs/CP045142-408559426933901848.xml","/CP045142_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045142_1.0.0-7.0.0.15525992.xml"],"md5sum":"9f49c57877d13d494ce225e09e909403","name":"CP045142.zip","release":"2021-02-03T03:24:05","revision":"0","sha1sum":"ef749a89f7e557db7daca0ec92f3f06d3eed3561","size":"35MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30116","a6b1a447-382a-5a4f-15B3-101715B30052","a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045142","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"d1f6d486a5d9456eb4b15539009012ca","version":"d0a1b47f94e048e7adc354afd74a4c4d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for Mellanox Open Ethernet cards"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.27.4000:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.27.2008:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>New Feature and Changes in Version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.29.1016:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<p><strong>New Feature and Changes in Version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Ethernet wqe_too_small Mode: A per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats:</li>\n\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused packets to drop due to header size issues and/or failing checks. This issue was caused due to a Linux issue that caused VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) might take longer than when MKEY_BY_NAME was disabled.</li>\n\t<li>In rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>An issue that caused the device to go to dead IRISC as one of the firmware semaphores could not be released when a speed change or port state change was triggered.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the eth_wqe_too_small counter to count ODP page faults.</li>\n\t<li>A low performance was observed after enabling the RoCE Accelerator capability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2288448","datemodified":"2021-01-22T07:14:32","file_list":["cp044733.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"8fdfa1afcce19041af3e29be8c39be24","name":"cp044733.exe","release":"2021-01-22T07:10:05","revision":"0","sha1sum":"c049ab43f27ce8b3fe24a44970397216711600d9","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"d217387da75b452f91f63bc9a4605e37","version":"51f971e4fd32409face04139ed2d2f7b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.6.165.0</p>\n\n<p>Added the following support :</p>\n\n<p><br />\nRemoved the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"19300214","languages":[{"lang":"en","x_late":"Firmware (Entitlement Required) - Storage Controller"},{"lang":"ja","x_late":"ファームウェア (ライセンスが必要) - ストレージコントローラー"}]}],"description":[{"lang":"tw","x_late":"此套件可更新連接智慧陣列控制器及主機匯流排配接卡的 HP D2600 與 D2700 磁碟機機櫃韌體。此套件內含的 I/O 模組韌體新增改善功能，可修正在初版產品發行後使用與額外資格測試期間發現的問題。"},{"lang":"en","x_late":"This package updates the firmware on HP D2600 and D2700 Disk enclosures attached to Smart Array Controllers and Host Bus Adapters. I/O module firmware included in this package adds improvements and corrects issues found during use and additional qualification testing after initial product release."},{"lang":"ko","x_late":"이 패키지는 스마트 어레이 컨트롤러 및 호스트 버스 어댑터에 장착되어 있는 HP D2600 및 D2700 디스크 인클로저의 펌웨어를 업데이트합니다. 이 패키지에 포함된 I/O 모듈 펌웨어에서는 제품 출시 후 사용 또는 추가 적격 테스트 과정에서 발견된 문제를 수정하고 개선 사항을 추가하였습니다."},{"lang":"cn","x_late":"该软件包用于更新连接至智能阵列控制器和主机总线适配器的HP D2600和D2700磁盘机柜固件。此软件包中包含的 I/O 模块固件添加了改进，并纠正了首次产品发布后在使用期间及额外资格测试时发现的问题。"},{"lang":"ja","x_late":"このパッケージは、Smartアレイコントローラーおよびホストバスアダプターに接続されているHP D2600およびD2700ディスクエンクロージャーのファームウェアをアップデートします。 このパッケージに含まれるI/Oモジュールのファームウェアは、初期リリース後、実際の使用中および追加テストで見つかった問題の改善と修正を追加します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2960312","datemodified":"2015-11-30T08:02:48","file_list":["./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/.hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/CAMSPR0150_6G_app_4MB_ai.pmc","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/CP028451.xml","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/ccissflash","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-0150-2.1/libstdc++.so.6","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP028451.scexe"],"md5sum":"4763adebb00e8b4fead750c8ebf16e6d","name":"hp-firmware-d2600-d2700-0150-2.1.x86_64.rpm","release":"2016-10-07T00:00:00","revision":"1","sha1sum":"265814f2e52f86301c88e0c088e97fe9573cf42f","size":"2MB","target_guids":[],"type_of_change":"1","version":"0150"}],"id":{"product":"ca5f8e8ad5cf4c9a9aaf2d63a599d335","version":"204b1cb605dc4eb9b666b1fd2975df06"},"installation":{"command":"hpsetup","command_params":"-iCAMSPR0150_6G_app_4MB_ai.pmc -v0150 -t\"D2600 SAS AJ940A\" -t\"D2700 SAS AJ941A\" -t\"260 SAS AJ940A\" -t\"270 SAS AJ941A\" -t\"D2x00 Disk Enc.\" -t\"MDS260 CAMARO\" -t\"MDS270 CAMARO\"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Firmware installation instructions for Smart Array configurations:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;hp-firmware-d2600-d2700-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./hpsetup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/hp-firmware-d2600-d2700-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the HP Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\"><u>HP Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"http://www.hp.com/swpublishing/MTX-40e268a99cc243a299352b7b20\" style=\"text-decoration: none; color: blue;\"><u>HP USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created HP Service Pack for ProLiant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hp/swpackages.</li>\n\t<li>Run the launch_hpsum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Special installation instructions for single-domain environments:</strong></p>\n\n<p>In a single domain configuration, I/O module A (top module) is connected to a SmartArray controller and I/O module B (bottom module) is unused. Even though the bottom I/O module is unused, both modules must have the same firmware version installed. Do the following to make sure that BOTH I/O modules are updated:</p>\n\n<ol>\n\t<li>Flash I/O module A of the first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After I/O module A is flashed successfully in the disk enclosures, shut down and turn off the server.</li>\n\t<li>Remove A/C power to the first and all cascaded disk enclosures.</li>\n\t<li>Label all cables connected to I/O module A of the first and all cascaded disk enclosures and then disconnect all cables from the I/O modules.</li>\n\t<li>Swap the positions of the I/O modules in the enclosure.</li>\n\t<li>Reconnect the cables to the top I/O module (it used to be the bottom I/O module) in the enclosure, using the labels to ensure that all cabling is connected properly, in the same configuration as before.</li>\n\t<li>Turn on the storage enclosures and wait for them to complete their startup routines.</li>\n\t<li>Turn on the server.</li>\n\t<li>After the server startup procedure is complete, flash the top I/O module (the new I/O module A) of first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After the I/O module is flashed successfully in the disk enclosures, power cycle the server to resume normal operation.</li>\n</ol>\n\n<p><strong>NOTES:</strong></p>\n\n<ul>\n\t<li>Use the -e or -f option when flashing a device, even if it is up to date.</li>\n\t<li>Use the -g option when downgrading.</li>\n\t<li>For details on supported command options, see the online help by executing the command ./CP0xxxxx.scexe or ./CP0xxxxx.scexe -h.</li>\n</ul>\n\n<p><strong>Installation Notes and Best Practices:</strong></p>\n\n<ul>\n\t<li>Before installing new firmware, review system requirements, enhancements list, fixes list, and other information in the firmware release notes, device QuickSpecs, and updated user documentation.</li>\n\t<li>Before installing new firmware, ensure that the system is stable and is not being reconfigured or changed in any way. If changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.</li>\n\t<li>Before installing new firmware, HP recommends creating a full backup of all data stored on the enclosure.</li>\n\t<li>When planning for a firmware update, schedule an appropriate time to perform an the update. Firmware updates must be performed during a system maintenance window, with all I/O to the system halted.</li>\n\t<li>After the installation process, verify system status in the software tools and confirm that the new firmware version is displayed as running on the enclosure.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smartアレイ構成のためのファームウェアのインストール手順：</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします：  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpm の内容を解凍します。</li>\n\t<li>CP0xxxxx.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'hp-firmware-smartarray-d6000-<version>-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます： </li>\n</ul>\n\n<p>               # ./CP0xxxxx.scexe ('/usr/lib/x86_64-linux-gnu/hp-scexe-compat'で実行)  (または)</p>\n\n<p>               # <em>./hpsetup</em> in the '/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-d2700-<version>-*' location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します： <em>rpm -e <rpm_package_name></em>、'.rpm'拡張子無しのrpmファイル名です。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、HP Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br /> <strong>オフライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://www.hp.com/swpublishing/MTX-40e268a99cc243a299352b7b20\" style=\"text-decoration: none; color: blue;\"><u>HP USB Key Utility</u></a>を使用して、<a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\"><u>HP Service Pack for ProLiant</u></a>をUSBキーに設置します。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したHP Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ルートでログイン（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.shを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p><strong>シングルドメイン環境での特別なインストール手順</strong></p>\n\n<p>シングルドメインの構成では、I/OモジュールA（上側のモジュール）は、Smartアレイコントローラーに接続し、I/OモジュールB（下側のモジュール）は使用されません。たとえ下側のI/Oモジュールが使われない場合でも、両方のモジュールは同じファームウェアバージョンがインストールされていなければなりません。必ず両方のI/Oモジュールがアップデートされるように、以下を実行してください。</p>\n\n<ol>\n\t<li>実行可能なファームウェアアップグレードを使用して、最初のI/OモジュールAと全てのカスケードされたディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャーでI/OモジュールAのフラッシュが成功した後、シャットダウンしてサーバーの電源を落とします。</li>\n\t<li>最初にA/C電源を、次にカスケードされた全てのディスクエンクロージャーを取り外します。</li>\n\t<li>最初のI/OモジュールAとカスケードされた全てのディスクエンクロージャーに接続されたケーブルにラベルを記載します。そして、I/Oモジュールからケーブルを取り外します。</li>\n\t<li>エンクロージャー内のI/Oモジュールの位置を交換します。</li>\n\t<li>以前の構成と同じように、全てのケーブル接続が正しいかラベルを確認して、エンクロージャー内の上側I/Oモジュール（下側I/Oモジュールとして使われていたもの）にケーブルを再接続します。</li>\n\t<li>ストレージエンクロージャーの電源を入れて、スタートアップルーチンの完了を待ちます。</li>\n\t<li>サーバーの電源を入れます。</li>\n\t<li>サーバーのスタートアッププロシジャーが完了後、実行可能なファームウェアアップグレードを使用して最初の上側I/Oモジュール（新しいI/OモジュールA）とカスケードされた全てのディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャー内のI/Oモジュールのフラッシュが成功した後、通常の動作に戻すため、サーバーの電源を入れ直します。</li>\n</ol>\n\n<p><strong>注:</strong></p>\n\n<ul>\n\t<li>それが最新であっても、デバイスをフラッシュするときには-eか-fオプションを使用してください。</li>\n\t<li>ダウングレードするときは、-gオプションを使用してください。</li>\n\t<li>サポートされているコマンド オプションの詳細は、\"./CP0xxxxx.scexe\" あるいは、\"./CP0xxxxx.scexe -h\"コマンドを実行してオンライン ヘルプを参照してください。</li>\n</ul>\n\n<p><strong>インストールノートおよびベストプラクティス</strong></p>\n\n<ul>\n\t<li>ファームウェアをインストールする前に、システム要件、拡張リスト、修正リストおよびファームウェアリリースノート、デバイスのQuick Specs、他のユーザードキュメントの情報を確認してください。</li>\n\t<li>新しいファームウェアをインストールする前に、システムが安定していて、再設定中または変更中ではないことを確認してください。もし何らかの変更が処理中ならば、それらを監視し、処理が完了するまで待ってからアップグレードを始めてください。</li>\n\t<li>新しいファームウェアをインストールする前に、エンクロージャー上に保存されている全てのデータのフルバックアップを作成することをおすすめします。</li>\n\t<li>ファームウェアをアップグレードする場合、アップグレードを実行する適切な時間をスケジュールします。ファームウェアのアップグレードは、システムの全てのI/Oを停止して、システムをメンテナンスする期間内に行う必要があります。</li>\n\t<li>インストールプロセス後、ソフトウェアツールのシステムステータスの確認と新しいファームウェアバージョンがエンクロージャー上で実行中と表示されることを確認してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (x64) 的 HP D2600/D2700 6Gb SAS 磁碟機櫃 ROM 更新元件"},{"lang":"en","x_late":"HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ko","x_late":"Linux (x64)용 HP D2600/D2700 6Gb SAS 디스크 인클로저 ROM 플래시 구성 요소"},{"lang":"cn","x_late":"用于Linux (x64)的HP D2600/D2700 6Gb SAS磁盘机柜ROM刷新组件"},{"lang":"ja","x_late":"HP D2600/D2700 6Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D2600 SAS AJ940A","target_guid":"","type":"msa"},{"id":"D2700 SAS AJ941A","target_guid":"","type":"msa"}],"supported_operating_systems":[{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-05-10T07:48:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"D2700","sw_key_expectedpath":"firmware:QLOGIC"},{"name":"D2600","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.42.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.42"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2226632","datemodified":"2020-12-17T12:16:07","file_list":["cp041523.xml","cpqsetup.exe","payload.json","setup.dll","UBM1_V1.42.hex.fw"],"md5sum":"4043153854df7fd322d1faeb710746c3","name":"cp041523.exe","release":"2020-12-17T12:01:32","revision":"0","sha1sum":"84fc9d25772c55764d7a524b2ccb35e60911a198","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.42"}],"id":{"product":"fed7882585434512b7259db2ba5790f0","version":"ea1298ea43df48f992d798bd59c9a584"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM1 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-10-24T06:35:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 6.7 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx5は、VMware ESXi 6.7 Mellanox Ethernetアダプター用ConnectX®-4およびConnectX®-5アダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"816737","datemodified":"2020-11-24T06:37:28","file_list":["/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip","/cp046264.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/doc/Mellanox_MLNX-NATIVE-ESX-ConnectX-4-5_Driver_for_VMware_ESXi_6.7_Release_Notes_v4_17_70_1.pdf","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/doc/README.txt","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/index.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.17.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.17.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip/vibs/nmlx5-rdma--5365993705185223579.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip/vibs/nmlx5-core--3857870122747664346.xml","/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-16089850.zip/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922-offline-bundle-16089850.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.17.70.1-1OEM.670.0.0.8169922.xml"],"md5sum":"07aa40c885c3435598da5d29dac2626b","name":"cp046264.zip","release":"2020-11-24T06:35:05","revision":"0","sha1sum":"2fd70f4c8a9c1f6715a5f6da040a0c46f7334288","size":"797KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx5-rdma","version":"4.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx5-core","version":"4.17.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"8e7aaa71b17c4086a95b8b9f64ce4863","version":"2348771c576f408ea0e56f6c69164335"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 6.7"},{"lang":"ja","x_late":"nmlx5_enドライバーコンポーネント for VMware 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.03.09:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 10/25Gb 2-port 642SFP28 Adapter (HPE Part Number: P24837-B21)</li>\n\t\t<li>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (HPE Part Number: P11338-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command&nbsp;was not supported.When running this command on a &quot;vmknic&quot;, a failure message&nbsp;was displayed.</p>\n\t</li>\n\t<li>\n\t<p>IPv6 as inner packet was not supported.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.11.11:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.17.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command&nbsp;was not supported.When running this command on a &quot;vmknic&quot;, a failure message&nbsp;was displayed.</p>\n\t</li>\n\t<li>\n\t<p>IPv6 as inner packet was not supported.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx5-rdma:4.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-core:4.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter(P23666-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000453</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5524394","datemodified":"2021-02-25T13:31:41","file_list":["20_29_1016-MCX653106A-ECA_HPE_Ax.pldm.signed","20_29_1016-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"fdf0e0874ccc607be48dfa8e967c32df","name":"20_29_1016-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:28:05","revision":"0","sha1sum":"134a3c224822c194ca59cd5fbaedc6da000f32f3","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"6ca4dd262131408db10af90451555128","version":"22261759bff242cc9d768699caebfdca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-12T10:55:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11501862","datemodified":"2021-01-28T10:13:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/CP046613.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/U30_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046613.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046613.scexe"],"md5sum":"fa6e834d524e3e09a15e157774345949","name":"firmware-system-u30-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T10:03:08","revision":"0","sha1sum":"8d73dfed3d4dbeb0f7a8da1d0697660eb6296d1f","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"1368ab3d45fb40b799c33ccbe297c322","version":"66b70385e3914913933aa5e389fcec82"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上 ROM 更新元件 - HPE ProLiant DL380 Gen10 (U30) 伺服器"},{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ko","x_late":"Linux용 온라인 ROM 플래시 구성 요소 - HPE ProLiant DL380 Gen10 (U30) 서버"},{"lang":"cn","x_late":"用于 Linux 的 ROM Flash 组件 - HPE ProLiant DL380 Gen10 (U30) 服务器"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen10(U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:14:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027405","datemodified":"2021-03-08T18:25:46","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"9b19062e20d318dc6d2be41b872182be","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"69e8751f557da72218c9b58062d693d082422476","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1055055","datemodified":"2021-03-08T18:21:31","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"d4788382bd188db5898b7abb8b5f0bfb","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"2d3b57753612f3f550c0a667f58118c5c5cc5ab8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"88b0a89daaf348e9967e08f08cad5650","version":"7e3f1a803b874274afd2472a9cd4d129"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3693064","datemodified":"2020-12-16T18:32:00","file_list":["cp045545.xml","cpqsetup.exe","HAKPFCGB.REL","payload.json","setup.dll"],"md5sum":"03eb0c23834453560ca73614c0bf114b","name":"cp045545.exe","release":"2020-12-16T18:20:05","revision":"0","sha1sum":"a90dea101dec3dfb7ff2cb11c589d760d4b7b8e7","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"8bec8c11bb254125b8c66405c5e73717","version":"319a4e81330642a9b203aeffb88a09b5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:48:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4837557","datemodified":"2020-12-13T16:28:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/CP045482.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/TAMG06ACHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045482.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045482.scexe"],"md5sum":"2e7d833402840a556f0aa08f8b1d9bca","name":"firmware-hdd-c993b31232-HPG4-3.1.x86_64.rpm","release":"2020-12-13T16:16:15","revision":"0","sha1sum":"24ac03877d9f979fa875585cb3f935ab33262c82","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"87b9a1c22150406cbf61d6b300753282","version":"5e4c37652d29404b8cc630c5464740c8"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR, and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15751235","datemodified":"2021-01-28T11:59:05","file_list":["/CP045679_BUILD_3.data","/CP045679.vmexe","/CP045679.vmexe64","/CP045679.vmfile","/CP045679_VMw.zip","/CP045679.xml","/payload.json","/CP045679_VMw.zip/index.xml","/CP045679_VMw.zip/vendor-index.xml","/CP045679_VMw.zip/metadata.zip","/CP045679_VMw.zip/vib20/CP045679/HPE_bootbank_CP045679_HPG1.3-7.0.0.15843807.vib","/CP045679_VMw.zip/metadata.zip/vendor-index.xml","/CP045679_VMw.zip/metadata.zip/vmware.xml","/CP045679_VMw.zip/metadata.zip/vibs/CP045679-3306288123547748478.xml","/CP045679_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045679_HPG1.3-7.0.0.15843807.xml"],"md5sum":"d11926f3a4ecef7eab9dbc78fa67eee2","name":"CP045679.zip","release":"2021-01-28T11:56:15","revision":"0","sha1sum":"ad42fba995b7c52285e9126db92a0c152b170cf7","size":"15MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045679","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"1af1a5a1ad4c4d1883e16ca0bd801d36","version":"dac299ac79e6448e8fb0e697aaecc16f"},"installation":{"command":"CP042539.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:17:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6925384","datemodified":"2021-01-08T14:08:14","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"04190331320e6a1ed5c98c33a72f6928","name":"kmod-netxtreme2-7.14.76-1.rhel7u9.x86_64.rpm","release":"2021-01-08T13:34:05","revision":"0","sha1sum":"5a4c15dd7a8418466c0e7254a1fcf873c35d52e4","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"6923143","datemodified":"2021-01-08T14:12:27","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"b03f16e70343b7ee6417e0c4b816ea6b","name":"kmod-netxtreme2-7.14.76-1.rhel7u8.x86_64.rpm","release":"2021-01-08T13:34:05","revision":"0","sha1sum":"136c553e6ccd0c42754d46849cfe7ef543d259c8","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"fd1884928c824890aec3a37db50b22e0","version":"af314421c84348a7bbaf951219b40415"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the driver Precision Time Protocol (PTP) is not working due to timestamp problem.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 9.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"581758","datemodified":"2021-01-28T09:46:05","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"26a808c224dc12d217f3b8e616e091ca","name":"elx-lpfc-kmp-default-12.8.352.11_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-28T09:35:10","revision":"0","sha1sum":"13fbc40f7e64bb65a3e5a984e0475201f39f30cb","size":"568KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"ff62b7c54afa40698c7ab166c3e4526e","version":"4e3a7ff5414e4f0fa878f1a33e34a0e9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6Dx-rel-22_29_1016-MCX623106AS-CDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101D15B30042","Version":"22.29.1016"},{"DeviceName":"Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6Dx-rel-22_29_1016-MCX623105AS-VDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101D15B30040","Version":"22.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE and HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter firmware on Windows Operating Systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (P25960-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000437</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000435</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"18167432","datemodified":"2021-01-27T08:38:36","file_list":["cp044271.xml","cpqsetup.exe","fw-ConnectX6Dx-rel-22_29_1016-MCX623105AS-VDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","fw-ConnectX6Dx-rel-22_29_1016-MCX623106AS-CDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"e3e1626034cf7954a2fcb6e84de585cf","name":"cp044271.exe","release":"2021-01-27T08:28:04","revision":"0","sha1sum":"47e57013e2715c4121c6d46de98a5287b807090a","size":"17MB","target_guids":["a6b1a447-382a-5a4f-15B3-101D15B30042","a6b1a447-382a-5a4f-15B3-101D15B30040"],"type_of_change":"1","version":"1.0.0.3"}],"id":{"product":"1158dc08ded5424bbf147255302cf823","version":"24d0d92e899c40adb7409cf156f3f39d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for Mellanox ConnectX6Dx Open Ethernet cards"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-28T09:22:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device&nbsp;is updated to 22.27.6008:</strong></p>\n\n<p>P25960-B21 (HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes in version 22.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Spectrum-3: 30.2007.1142</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Spectrum-2: 29.2007.1142</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Switch SDK: 4.4.0920</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;SONiC/SAI: 201911</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;ConnectX-6 Dx: 22.27.2008</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; *Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link speeds.</p>\n\n<ul>\n\t<li>Programmable Congestion Control (PCC) is at GA level.</li>\n\t<li>Enabled TLS offload v1.3 with key size 256.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been resolved in firmware version 22.27.6008:</strong></p>\n\n<ul>\n\t<li>Encapsulated RoCE traffic to drop when IB padding was required.</li>\n\t<li>PortXmitWait HW counter to count when not expected due to an inaccuracy in the counter.</li>\n\t<li>On dual-port device after Rx buffer modification the Physical Function on the second port got restored although no expected. &nbsp;The Rx buffer changes when all Physical Functions resets over one port (through reboot /driver restart / FLR) while there were active Physical Functions over the second port.</li>\n\t<li>Previous Shared Buffer modifications being overrun after performing Shared Buffer modifications such as SBPR, SBPM, SBCM, the PFCC Flow Control).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is updated to 22.29.1016:</strong></p>\n\n<p>&nbsp;</p>\n\n<p>P25960-B21 (HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter)</p>\n\n<p>P10180-B21 (Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes in version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n</ul>\n\n<ul>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Optimized vDPA performance for PPS in scalability of up to 127 devices per port.</li>\n\t<li>When using a Multi-Host device, the firmware can now discover who is the external SmartNIC host (the Embedded CPU PF (ECPF) ) with the highest index that is responsible for performing offload activities to the adapter card.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Eye-Opening: supported only when using NRZ signal. (Beta)</li>\n\t<li>Option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order. To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command and set DPP relevant attributes.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>Error statistics and reporting for vDPA.</li>\n\t<li>IPv6 TSO offload.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been resolved in firmware version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Traffic for virtio hardware offload solution was prevented from &quot;iperf3&quot; in Windows Operating System.</li>\n\t<li>Traffic for virtio hardware offload solution was prevented from &quot;iperf3 -i 512&quot;.</li>\n\t<li>The struct virtio_net_hdr was not set properly by the virtio hardware offload solution. The following message appeared in dmesg during traffic: &quot;bad gso: type xx, size: xx&quot;.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) might had taken longer than that of when MKEY_BY_NAME was disabled.</li>\n\t<li>TCP/IP traffic received by the guest kernel with version higher than 4.10 were&nbsp;unstable because of corrupted GSO header. The following message could be seen from dmegs: &quot;bad gso: type: xx, size: xxxx&quot;.</li>\n\t<li>Enabling the RoCE Accelerator capability resulted in low performance<br />\n\tNote:&nbsp;The fix is available when all ports are set as Ethernet.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG1"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG1"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG1"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows&nbsp; Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7408200","datemodified":"2020-12-11T19:07:06","file_list":["cp045586.xml","cpqsetup.exe","K503HPG1.rel","payload.json","setup.dll"],"md5sum":"83184f9acd53115fee3d04990ed6f4ce","name":"cp045586.exe","release":"2020-12-11T18:58:04","revision":"0","sha1sum":"95ab81399c3e93200afb9055fee40ef450b911ee","size":"7MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"8ebc8805a4344ec4a24a5c7109c6e07f","version":"65061afb383e470e9c7f6960b19e4067"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:04:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"17386615","datemodified":"2021-01-27T15:31:47","file_list":["/CP045613_BUILD_4.data","/CP045613.vmexe","/CP045613.vmexe64","/CP045613.vmfile","/CP045613_VMw.zip","/CP045613.xml","/payload.json","/CP045613_VMw.zip/index.xml","/CP045613_VMw.zip/vendor-index.xml","/CP045613_VMw.zip/metadata.zip","/CP045613_VMw.zip/vib20/CP045613/HPE_bootbank_CP045613_HPD6.4-7.0.0.15843807.vib","/CP045613_VMw.zip/metadata.zip/vendor-index.xml","/CP045613_VMw.zip/metadata.zip/vmware.xml","/CP045613_VMw.zip/metadata.zip/vibs/CP045613-3818907349546790869.xml","/CP045613_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045613_HPD6.4-7.0.0.15843807.xml"],"md5sum":"6c0104b77ec9937d16eb47fcd3d02a35","name":"CP045613.zip","release":"2021-01-27T15:29:05","revision":"0","sha1sum":"ef65973cbaa3e90e2151873d162c4ebba753ea16","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP045613","version":"HPD6.4-7.0.0.15843807"}]}],"id":{"product":"4d6b330d7f1d4462bea2b4b6ff4f5e4a","version":"f400fbd3c91f4758bd978bf417ba3cb2"},"installation":{"command":"CP040624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:17:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11589248","datemodified":"2021-01-28T10:10:42","file_list":["cp046626.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_2.42_01_23_2021.signed.flash"],"md5sum":"ec934f46a604d7c7e41b3a58c097f634","name":"cp046626.exe","release":"2021-01-28T10:07:06","revision":"0","sha1sum":"fcdd32cc62adb84584e1c991b1d7f9b08470eb80","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"36877a0ed97d40a29cfe6cb469a6e72f","version":"155f2be6f76445f3ba2b890959cee8bd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1710613","datemodified":"2020-12-02T10:49:50","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i915.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-kvmgt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vfio_mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/i915.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/kvmgt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/mdev.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"b78b4721fa8636a7d302d8b758430016","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel7u8.x86_64.rpm","release":"2020-12-02T09:25:04","revision":"0","sha1sum":"8e8f662db2f4973f3b152a24789fac238d119464","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"2257342","datemodified":"2020-12-02T10:55:47","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"744485dfcb9f144b67127d2803a04989","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel7u8.x86_64.rpm","release":"2020-12-02T09:25:04","revision":"0","sha1sum":"02dde63bf50142f4108f7cf1f443c86946345fa7","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"5ef718b94f9643ad8517d0050338c700","version":"4d035c53925a4c87966439d6ecb634b3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel7u8.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HP Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1025504","datemodified":"2020-12-02T17:25:23","file_list":["cp045179.xml","cpqsetup.exe","cp_data.xml","install.xml","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"96cfa4d8770ef91ae69e90892a2b3574","name":"cp045179.exe","release":"2020-12-02T17:11:09","revision":"0","sha1sum":"78ac09b544a2e68ea4476101a12c6c67a2bf7a2d","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"f5e3995830b040538ed866e14afc4c24","version":"fa6e7ba979934b8cabc2bc12f19a5fa1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, vxnmsg.dll, nicco5.dll, and nicinvxn.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for Broadcom NetXtreme-E devices for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2019用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1037584","datemodified":"2021-01-14T09:02:14","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045255.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"dcbdfba8c0c13328596a6ea6a7854d6b","name":"cp045255.exe","release":"2021-01-14T08:48:05","revision":"0","sha1sum":"b62534e3bb020cd958fe32f3194f2780210982b3","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"d936b2fd4e0c4dcb9d5ef13b3d9dbd87","version":"ed2692789a624911b99c3e9c3d9a446c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NetXtreme-E Driver for Windows Server 2019"},{"lang":"ja","x_late":"Broadcom NetXtreme-Eドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41593","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41592","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41593","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41592","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41595","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41594","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41597","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41596","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41595","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41597","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41596","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D6","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41593","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41593","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41595","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41594","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41597","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41595","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41594","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41596","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes BSOD observed after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20535687","datemodified":"2021-03-23T21:42:24","file_list":["/CP047337_BUILD_2.data","/CP047337.vmexe","/CP047337.vmexe64","/CP047337.vmfile","/CP047337_VMw.zip","/CP047337.xml","/payload.json","/CP047337_VMw.zip/index.xml","/CP047337_VMw.zip/vendor-index.xml","/CP047337_VMw.zip/metadata.zip","/CP047337_VMw.zip/vib20/CP047337/HPE_bootbank_CP047337_HPK3.2-7.0.0.15843807.vib","/CP047337_VMw.zip/metadata.zip/vendor-index.xml","/CP047337_VMw.zip/metadata.zip/vmware.xml","/CP047337_VMw.zip/metadata.zip/vibs/CP047337-5576380489821347970.xml","/CP047337_VMw.zip/metadata.zip/bulletins/Smart-Component-CP047337_HPK3.2-7.0.0.15843807.xml"],"md5sum":"6527cb69e2f6a7509140580170aa2553","name":"CP047337.zip","release":"2021-03-23T21:38:04","revision":"0","sha1sum":"de574d019bf08f163e2d08e93ef825039cf49a95","size":"19MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3","vib_list":[{"name":"CP047337","version":"HPK3.2-7.0.0.15843807"}]}],"id":{"product":"2fa1597649f243c092f040a8ecf90232","version":"a8ff8cfac95e484bbcb8cf0dfe828ea3"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-23T10:20:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3i version 2.1.5.0</li>\n\t<li>qcnic, version 2.0.57.0</li>\n\t<li>qfle3, version 1.4.12.0</li>\n\t<li>qfle3f, version 2.1.14.2&nbsp;</li>\n</ul>\n"}],"files":[{"bytes":"1493243","datemodified":"2021-01-18T03:43:26","file_list":["/cp045082.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.57.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.5.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.12.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.14.2-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3f--3196541751359997041.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qcnic--8985520576553058483.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3--3377191137913857898.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3i--3210215708116908819.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807.xml"],"md5sum":"931f4b0b2a43ed937b7cc2384d66d57e","name":"cp045082.zip","release":"2021-01-18T03:42:05","revision":"0","sha1sum":"26e20ba59cf1f4722d198cf05b20a72452598f08","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qcnic","version":"2.0.57.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.5.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.12.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.14.2-1OEM.700.1.0.15843807"}]}],"id":{"product":"38b83226aeb64480960e8558ac22cab4","version":"8e81a9c392934df8a2dba3a99af357eb"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen during traffic scheduling.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.135.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qfle3:1.4.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:2.0.57.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:2.1.5.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:2.1.14.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Windows 64 bit operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1612440","datemodified":"2020-12-07T09:06:43","file_list":["cp046397.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"md5sum":"9bb5fbf9c60f2116fc926c8b001d4f10","name":"cp046397.exe","release":"2020-12-07T09:03:09","revision":"0","sha1sum":"fc311d6f351ace11517901ebae32bdaae453b0c2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"664b59f2e0844d92994001b0975488e2","version":"4f0319a861474b8fb1a5d09d4d109636"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>For detailed information about configurable components, see the<em> Smart Update Manager User Guide </em>at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us</a>.</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN Enablement Kit for Windows 64 bit operating systems"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-07T07:25:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLSMARTSANVer.exe","sw_key_expectedpath":"%SystemDrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n     </strong>Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <strong> </strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3383728","datemodified":"2020-12-17T08:01:33","file_list":["cp045516.xml","cpqsetup.exe","payload.json","setup.dll","TATCATSATAG1.REL"],"md5sum":"e88dffd6a58e398fcab720f93e6870d0","name":"cp045516.exe","release":"2020-12-17T07:53:09","revision":"0","sha1sum":"962d2953cd4dddc2ba8d0b55daed8394166af6bf","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3d1400a6e0204fb498134f7e6e3f374a","version":"2a9e8bcb26184290af1f6774747a33ca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:38:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"}]}],"description":[{"lang":"tw","x_late":"提供各種公用程式，以支援 HPE 支援的光纖通道主機匯流排配接卡驅動程式。"},{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."},{"lang":"ko","x_late":"HPE 지원 파이버 채널 호스트 버스 어댑터 드라이버의 다양한 유틸리티를 제공합니다."},{"lang":"cn","x_late":"提供支持 HPE 支持的光纤通道主机总线适配器驱动程序的其他实用程序。"},{"lang":"ja","x_late":"HPEのサポートされるファイバーチャネルホストバスアダプタードライバーのサポートに各種ユーティリティを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"28026","datemodified":"2020-06-15T10:17:19","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/adapter_info_nx","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/adapter_info_nx","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"9b020ab28d45ce5d027b6457acc0a02b","name":"fibreutils-4.1-1_rhel.x86_64.rpm","release":"2020-06-15T10:14:05","revision":"0","sha1sum":"8832396609f6523cec4caa3aa693fea7cbe041d8","size":"27KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.1-1"}],"id":{"product":"C8691","version":"d95fe42121e94210a46334bf546bf938"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"下載 fibreutil RPM。 <BR>使用 rpm -Uvh 命令來安裝/升級 RPM。"},{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."},{"lang":"ko","x_late":"fibreutils RPM을 다운로드합니다. <BR>rpm -Uvh 명령을 사용하여 RPM을 설치/업그레이드합니다."},{"lang":"cn","x_late":"下载 fibreutils RPM。 <BR>使用 rpm-Uvh 命令以安装/升级 RPM。"},{"lang":"ja","x_late":"fibreutils RPMをダウンロードします。 <BR>\nRPMをインストール/アップグレードするには、rpm -Uvhコマンドを使用してください"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -Red Hat Enterprise Linux (RHEL)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"338F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c338f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"338E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c338e","type":"pci","ven":"1077"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-26T08:48:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p>\n","latest_fixes_x_late":"<p>Fiixed adpater_info code to display correct Vendor name&nbsp;instead of Unknown</p>\n"},{"curr_enhancements_x_late":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。MO001600KWZQPおよびMO003200KWZQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"}],"files":[{"bytes":"9357700","datemodified":"2021-01-20T23:16:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/CP045988.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/GP173500HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045988.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045988.scexe"],"md5sum":"a5757d3406b4340cf261a5b44229621d","name":"firmware-hdd-95b6ae2e85-HPK5-1.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"7a7cdb7cc586a012fb0bd7d924528e813eb59d62","size":"8MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK5"}],"id":{"product":"5cda8f412fa0418489dbcbbf3f49c1b5","version":"301e8453cfd041eab752bb3a450f012d"},"installation":{"command":"CP041864.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:27:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1229883","datemodified":"2021-03-08T20:10:56","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"7e10600de1fa70c3be7a3603d5327a93","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"982971925273ba8a69c6294818608eb516283686","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1051883","datemodified":"2021-03-08T20:13:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"50ad8b53edcccb1285ff8d3ed3b04f85","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"8b114edaae92c28d45a32b0d846154fe71edcd7e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"d05081ab9ef4444a874a5310ab9eff91","version":"d563d7b60897419bb0d727b5ecae0aac"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16693319","datemodified":"2021-01-28T18:41:51","file_list":["/CP045711_BUILD_3.data","/CP045711.vmexe","/CP045711.vmexe64","/CP045711.vmfile","/CP045711_VMw.zip","/CP045711.xml","/payload.json","/CP045711_VMw.zip/index.xml","/CP045711_VMw.zip/vendor-index.xml","/CP045711_VMw.zip/metadata.zip","/CP045711_VMw.zip/vib20/CP045711/HPE_bootbank_CP045711_HPD8.3-7.0.0.15843807.vib","/CP045711_VMw.zip/metadata.zip/vendor-index.xml","/CP045711_VMw.zip/metadata.zip/vmware.xml","/CP045711_VMw.zip/metadata.zip/vibs/CP045711--2152450945082264111.xml","/CP045711_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045711_HPD8.3-7.0.0.15843807.xml"],"md5sum":"73cbe80db880c62b44c74cbb260417b9","name":"CP045711.zip","release":"2021-01-28T18:38:03","revision":"0","sha1sum":"4f6c4138f745ef720ffff8cbdc4fef50a80c50c9","size":"15MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP045711","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"b197b25ba5a84d17992b28174218a00a","version":"c8fe284a6be14bc89b909e10f700ee1b"},"installation":{"command":"CP042469.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:42:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:Â <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5898107","datemodified":"2020-10-29T18:21:31","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/CP046197.xml","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/U25_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u25-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046197.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046197.scexe"],"md5sum":"8737cf7154f4946bc49b89f90361fb50","name":"firmware-system-u25-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-29T18:12:05","revision":"0","sha1sum":"698561a0d11d94dcd1eb25fb1e3fdb17a52ec4a2","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"760219007fb741b7ab3268ea14a28fcd","version":"7aac8abd98544636aff02ea61e5d378a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL270d (U25) Accelerator Tray"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL270d (U25) アクセラレータトレイ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-29T18:07:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"}],"sw_keys":[{"name":"U25","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller.  This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"lang":"ja","x_late":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"570576","datemodified":"2020-11-26T08:59:36","file_list":["cp046356.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"md5sum":"23451684274b5d37e125cfb6500a245a","name":"cp046356.exe","release":"2021-04-23T00:00:00","revision":"1","sha1sum":"a16174afc8973c32a5899f4993723d2443a60058","size":"557KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"2db44a1decee40ff8a1a633e86c57d5c","version":"9146bb3190814c4eb84a8024df948900"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-28T10:24:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed branding issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"necheschif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB010000GWAYN and MB008000GWAYL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB010000GWAYNおよびMB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6023842","datemodified":"2020-12-13T12:46:01","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/CP045416.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/HLIBRHHaseFG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045416.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045416.scexe"],"md5sum":"b1c954be84068ee337f3dd4336a27147","name":"firmware-hdd-cc819d4bff-HPG5-6.1.x86_64.rpm","release":"2020-12-13T12:34:04","revision":"0","sha1sum":"7e34d367893cc4cbb352fc69ad2d818fadc7f520","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"ff5f0967b6c84e77920662313dc42a52","version":"cdf02b47346d477d93d8c0781c3cfc66"},"installation":{"command":"CP040327.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWAYN and MB008000GWAYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"4441977","datemodified":"2021-02-16T06:08:11","file_list":["/cp044434.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/index.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vendor-index.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/ilo_670.10.7.0.4-1OEM.670.0.0.7535516.vib","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/sutesxcli-6.7.0.2.8.0.0-9.vib","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/sut-6.7.0.2.8.0.0-19.vib","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vmware.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vendor-index.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/bulletins/sut-esxi6.7-offline-bundle-2.8.0.0-18.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vibs/ilo-5382991387560295609.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vibs/cru--1581854872647123919.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vibs/sut--1991550593203527171.xml","/sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/metadata-sut-esxi6.7-offline-bundle-2.8.0.0-18.zip/vibs/sutesxcli--3164569225734659149.xml"],"md5sum":"a77dff9af867b785f4b29f8366b54fb3","name":"cp044434.zip","release":"2021-02-16T06:06:04","revision":"0","sha1sum":"d4f327e3c17e7f8683484b2f87667c0e43d674bd","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf680a7e2","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ece09b5689","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"type_of_change":"1","version":"2021.04.00","vib_list":[{"name":"ilo","version":"670.10.7.0.4-1OEM.670.0.0.7535516"},{"name":"sutesxcli","version":"6.7.0.2.8.0.0-9"},{"name":"sut","version":"6.7.0.2.8.0.0-19"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"}]}],"id":{"product":"af9477b9fa00462698ac47498ea633b5","version":"dd3be1b1df9944b49f6055e241d06d1a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T13:53:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sutesxcli:6.7.0.2.8.0.0-9","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"sut:6.7.0.2.8.0.0-19","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:670.10.7.0.4-1OEM.670.0.0.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596606","datemodified":"2021-01-28T09:33:45","file_list":["payload.json","U31_2.42_01_23_2021.signed.flash","U31_2.42_01_23_2021.xml"],"md5sum":"ead32e57cb74cf385df1348e5da1137b","name":"U31_2.42_01_23_2021.fwpkg","release":"2021-01-28T09:26:16","revision":"0","sha1sum":"9fe0ffa23638346a1fdd8135c412fcd775bf6b9a","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"4de9a363a422456faca983d193ca352a","version":"372b151edf3c48a0b85b9ff026b6c26a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.42_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.42 (02/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34207112","datemodified":"2021-02-25T11:48:32","file_list":["A46_2.42_02_23_2021.signed.flash","cp046930.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"4ad507d995eaa6a862ad2d34fc5957c8","name":"cp046930.exe","release":"2021-02-25T11:46:30","revision":"0","sha1sum":"4b272ace31bce8b048a4e79224ce419478bb6bb1","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"2.42_02-23-2021"}],"id":{"product":"d00882018d64492aa4a5bc81f394c4dc","version":"99670676551745dbae24e130eb0f45c0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-22T16:10:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed an issue where the chassis name was not being reported for inventory control.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>System Programable Logic CPLD version 34<P><B>Problems Fixed:</B></P>Addressed an issue that could cause a slight degradation of performance.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8700008","datemodified":"2020-11-03T04:54:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/CP045753.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/U44_2.20_10_27_2020.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.20_2020_10_27-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045753.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045753.scexe"],"md5sum":"6b9cb579602ebf3a539986ff3369b1f4","name":"firmware-system-u44-2.20_2020_10_27-1.1.x86_64.rpm","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"37cddd61b09dbfb8b194b8705d54bf95c4823fa0","size":"8MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"824707fd6d4844feaef370452b0a3a3e","version":"09037019499b4a2daffc07b220d87631"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1315859","datemodified":"2021-01-26T23:13:16","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"85f7452c87b40a6ac5789c4f98335d15","name":"kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u8.x86_64.rpm","release":"2021-01-26T21:55:04","revision":"0","sha1sum":"9e24d5a705ef20f60aec55f7200bda7a02a80cb8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1260859","datemodified":"2021-01-26T23:09:56","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/libexec/rdma-set-sriov-vf","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.0","./usr/share/doc/dpcp-1.1.0/README","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibverbs-52mlnx1","./usr/share/doc/libibverbs-52mlnx1/libibverbs.md","./usr/share/doc/librdmacm-52mlnx1","./usr/share/doc/librdmacm-52mlnx1/librdmacm.md","./usr/share/doc/libvma-9.2.2","./usr/share/doc/libvma-9.2.2/README.txt","./usr/share/doc/libvma-9.2.2/VMA_VERSION","./usr/share/doc/libvma-9.2.2/journal.txt","./usr/share/doc/rdma-core-52mlnx1","./usr/share/doc/rdma-core-52mlnx1/COPYING.BSD_FB","./usr/share/doc/rdma-core-52mlnx1/COPYING.BSD_MIT","./usr/share/doc/rdma-core-52mlnx1/COPYING.GPL2","./usr/share/doc/rdma-core-52mlnx1/COPYING.md","./usr/share/doc/rdma-core-52mlnx1/README.md","./usr/share/doc/rdma-core-52mlnx1/tag_matching.md","./usr/share/doc/rdma-core-52mlnx1/udev.md","./usr/share/licenses/dpcp-1.1.0","./usr/share/licenses/dpcp-1.1.0/LICENSE","./usr/share/licenses/libvma-9.2.2","./usr/share/licenses/libvma-9.2.2/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"7762309054b7b8043b3d844f4bdb7410","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u8.x86_64.rpm","release":"2021-01-26T21:55:04","revision":"0","sha1sum":"c7b0c6c2d105c399c75eab552c04d5ddecf9f6b8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"63a0b4d1fd5143328925661934c3ed2a","version":"2895c0aa6513432da679e81ca802c988"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u8.x86_64.rpm mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD4"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"2984304","datemodified":"2020-12-17T12:19:36","file_list":["cp045505.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXe0HPD4.REL"],"md5sum":"fbee1df77d083119e1ba41cac4c7fa27","name":"cp045505.exe","release":"2020-12-17T12:05:11","revision":"0","sha1sum":"a695ae26f7ecfab4b4ece3cc151879558cbe2c1d","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"7e6f42aebfdb4390968da43b36518880","version":"0b1ae9cd6a5349fcb4307e9c7c256f3a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:34:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: XP0120GFJSL and XP0240GFJSN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。XP0120GFJSLおよびXP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17249130","datemodified":"2021-01-28T13:52:56","file_list":["/CP045693_BUILD_3.data","/CP045693.vmexe","/CP045693.vmexe64","/CP045693.vmfile","/CP045693_VMw.zip","/CP045693.xml","/payload.json","/CP045693_VMw.zip/index.xml","/CP045693_VMw.zip/vendor-index.xml","/CP045693_VMw.zip/metadata.zip","/CP045693_VMw.zip/vib20/CP045693/HPE_bootbank_CP045693_HPS4.3-7.0.0.15843807.vib","/CP045693_VMw.zip/metadata.zip/vendor-index.xml","/CP045693_VMw.zip/metadata.zip/vmware.xml","/CP045693_VMw.zip/metadata.zip/vibs/CP045693--2290559102703044487.xml","/CP045693_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045693_HPS4.3-7.0.0.15843807.xml"],"md5sum":"fa3efed6ee2390d6ff26fa095e39c2a0","name":"CP045693.zip","release":"2021-01-28T13:50:05","revision":"0","sha1sum":"786c9cd61bab849caa4305636a0b4dd1116a2f4a","size":"16MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4","vib_list":[{"name":"CP045693","version":"HPS4.3-7.0.0.15843807"}]}],"id":{"product":"71f736a9e5684fd69f80904bf78b29e9","version":"2b7fdd3a7c274bdea28db8ee0c471f65"},"installation":{"command":"CP040520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:28:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6153185","datemodified":"2020-10-28T22:12:59","file_list":["./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/CP046094.xml","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/I38_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-i38-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046094.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046094.scexe"],"md5sum":"728b7ea658ba0e317def219f6a141d5b","name":"firmware-system-i38-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-28T22:03:10","revision":"0","sha1sum":"7555192c368cc6401efa244413769086621d2cd8","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"2cade22bb0f84fafbf250afecb7afed8","version":"22a50b5139094a71ab5c13ffc8671d1d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant BL660c Gen9(I38)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T02:01:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5780351","datemodified":"2020-12-18T02:02:31","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/CP046425.xml","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/U23_2.90_11_27_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u23-2.90_2020_11_27-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046425.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046425.scexe"],"md5sum":"7f5a3ca2da4cd7053a3c08aa506b033d","name":"firmware-system-u23-2.90_2020_11_27-1.1.i386.rpm","release":"2020-12-18T01:53:14","revision":"0","sha1sum":"80b78473671918b71f91dbdfb5c5bacb76c0337b","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020"}],"id":{"product":"a15fe0bcd3c0422abe0c1c2506d32d09","version":"ef799ebf0e18406497321c1c09645963"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:09:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic Multifunction NX2 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP0."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP0で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"99653","datemodified":"2020-02-12T18:46:13","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/58","./usr/lib/.build-id/58/fe7d350ee7eaa2f145b44b6dd9b009820cfdb8","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"708fcc9752139edda10aae52b0f2886a","name":"iscsiuio_bl-2.11.5.13-3.sles15sp0.x86_64.rpm","release":"2020-02-12T18:45:04","revision":"0","sha1sum":"79e6b84d41f21c160a100164525f585cb917ad99","size":"97KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"353da98f5ded4f35807a605192278e9f","version":"6630e026aa824f819547eacd3720a502"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP0"},{"lang":"ja","x_late":"HPE Blade QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI BFS failure with VLAN.</p>\n\n<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n\n<p>This product addresses an issue where&nbsp;an iSCSI portal is&nbsp;discovered with invalid an VLAN ID.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6290646","datemodified":"2020-11-04T07:30:26","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/CP046144.xml","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/P92_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p92-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046144.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046144.scexe"],"md5sum":"f3c7e7991e4bb58fcf85b8c61156a039","name":"firmware-system-p92-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-04T07:19:07","revision":"0","sha1sum":"1e56c57fc0f811b0c8e3a9756d25fb6cd37d48ae","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"ce67f450aba744c2b5fc3e256cda38aa","version":"f58826691d8540a791a67831e3f5c4f6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML350 Gen9(P92)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T05:27:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"352136","datemodified":"2019-12-04T06:28:24","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./sbin/rchp-health","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"14c57c7fe1b462253cbe6f82c8f8a1d8","name":"hp-health-10.92-6.6.sles15.x86_64.rpm","release":"2019-12-04T06:04:04","revision":"0","sha1sum":"d547656a8ef299bec6663832a7d833ebc39bb6fc","size":"343KB","target_guids":[],"type_of_change":"0","version":"10.9.2"}],"id":{"product":"b243398aaeca47f7be44fb080b998e4c","version":"96ff02627e234c0d8d0bd71f16b745b7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-21T13:56:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Modified the loop initial values in hpasmcli from 2 to 0.</li>\n\t<li>Modifications to check the read and write variables to match RBSU in Legacy and UEFI mode</li>\n\t<li>Updated the hpasmcli check string to correctly report the impitool information.</li>\n\t<li>Remove the redundant serial embedded and com ports</li>\n\t<li>Addressed&nbsp;IML message size limitation from 36 to 212 bytes</li>\n\t<li>Support for hp-health in OS security boot</li>\n\t<li>Added supporting &ldquo;quote mark&rdquo; in SET NAME command</li>\n\t<li>Enabled to set PXE as boot first&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16921321","datemodified":"2021-01-28T15:47:48","file_list":["/CP045664_BUILD_3.data","/CP045664.vmexe","/CP045664.vmexe64","/CP045664.vmfile","/CP045664_VMw.zip","/CP045664.xml","/payload.json","/CP045664_VMw.zip/index.xml","/CP045664_VMw.zip/vendor-index.xml","/CP045664_VMw.zip/metadata.zip","/CP045664_VMw.zip/vib20/CP045664/HPE_bootbank_CP045664_HPG2.3-7.0.0.15843807.vib","/CP045664_VMw.zip/metadata.zip/vendor-index.xml","/CP045664_VMw.zip/metadata.zip/vmware.xml","/CP045664_VMw.zip/metadata.zip/vibs/CP045664-4791678427540336153.xml","/CP045664_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045664_HPG2.3-7.0.0.15843807.xml"],"md5sum":"a25bd96db58d29f60ca665d635be6740","name":"CP045664.zip","release":"2021-01-28T15:45:04","revision":"0","sha1sum":"f5884e4556e50cf338f501b740d345c9985920ef","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045664","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"543d676d322b4e8ab4ce97b5bffa1a41","version":"f44687c8dcd64c7abd89abc29bd744da"},"installation":{"command":"CP040549.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYYU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:05:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"745996","datemodified":"2021-03-23T01:37:46","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"92cad74dac02e2b281d0f224c6411d44","name":"hp-ams-2.10.3-877.3.sles15.x86_64.rpm","release":"2021-03-23T01:29:05","revision":"0","sha1sum":"ff22672010ee3cf84eb72b33f6deff5aed8fa672","size":"728KB","target_guids":[],"type_of_change":"0","version":"2.10.3"}],"id":{"product":"3dd3ab05c92946afa133f2b171e42532","version":"bd0709790e3f448c85ecd1e2a9d6ef09"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-22T16:11:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Enhancements added in this release:</p>\n\n<ul>\n\t<li>Support for SUSE Linux Enterprise Server 15 Service Pack 2&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the Following Items:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added&nbsp;the warning message for users to restart hp-ams service when iLo reset more than twice. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099805en_us\" style=\"color:#0563c1; text-decoration:underline\">a00099805en_us</a>.&nbsp;&nbsp;</li>\n\t<li>When the server detects the physical network cable is plugged or unplugged, hp-ams will send out a trap to notify the administrator about the&nbsp;physical network status change.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VR000150GWEPP および VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n      </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"2820848","datemodified":"2020-12-11T21:20:08","file_list":["4IDMHPG1.rel","cp045581.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"ce7fd22fa8fbd40490b3863934eae3bd","name":"cp045581.exe","release":"2020-12-11T21:06:05","revision":"0","sha1sum":"478d16f3c98c38f4ff5ad5332bf827f17837c5b0","size":"2MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"7a5bb5126715458dbee6bc8ea5d0f887","version":"bf8418db76594023a69e3b161995c0c7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VR000150GWEPP and VR000480GWEPR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:02:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times. </li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This release corrects logical block address mismatches that could results in partial or total data loss.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5222400","datemodified":"2020-12-13T16:38:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/CP045845.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/hbcpssssefd3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045845.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045845.scexe"],"md5sum":"e2e16c95094a3b0be4a4a892a1f18b25","name":"firmware-hdd-ef93133161-HPD3-2.1.x86_64.rpm","release":"2020-12-13T16:26:05","revision":"0","sha1sum":"52e7ce19fa07093e2156c8b8f8551058a198c703","size":"4MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"07a5f3ddb9bd4168818fb38406e49473","version":"86714b3d614c42dcafc335f58ebfb260"},"installation":{"command":"CP040353.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-07T11:20:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This release corrects logical block address mismatches that could results in partial or total data loss.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5910728","datemodified":"2020-11-04T11:28:52","file_list":["SignedImageInstaller64.dll","U21_2.80_10_16_2020.signed.flash","cp046174.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"299a4df474e81b9f201a1e9e643d3538","name":"cp046174.exe","release":"2020-11-04T11:12:07","revision":"0","sha1sum":"e53309859d9663a3ed1b8a506cebf50ae5af0565","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"f9c6be089c7b4d0089fc2a6d2c32cc55","version":"97abd2efacfc4bfdae192af24486707f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL450 Gen9 (U21)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T07:49:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5938544","datemodified":"2020-10-28T22:20:00","file_list":["I38_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046093.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"adc786b25ed27222f0ab772c92e93842","name":"cp046093.exe","release":"2020-10-28T22:03:05","revision":"0","sha1sum":"90facdcf90c3e9f4724246dfaed14412949e7931","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"c67540411e6b4fb08ed7b6799938f22f","version":"c4a83114b69343288bcd275913f52148"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant BL660c Gen9 (I38)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:55:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Microsoft Windows Server 2012 R2 執行的 HPE Intel i40ea 10 Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2012 R2에서 실행되는 HPE Intel i40ea 10기가비트 이더넷 NIC용 드라이버가 들어 있습니다."},{"lang":"cn","x_late":"此组件包包含的驱动程序适用于在Microsoft Windows Server 2012 R2环境下运行的HPE Intel i40ea 10千兆以太网卡。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1253272","datemodified":"2021-01-08T16:20:25","file_list":["cp045124.xml","cpqsetup.exe","cp_data.xml","i40ea64.cat","i40ea64.din","i40ea64.inf","i40ea64.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"19b7231aa55bca4ec1b2fad0ffd0b545","name":"cp045124.exe","release":"2021-01-08T16:06:04","revision":"0","sha1sum":"78188b9cf50ca0656064e5b129a7c02eccd34270","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc261833"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"d1dc734770d8403db0527a4d4393f35a","version":"0940f479dfe24710aec0c6f45c90e8d2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br><p>從該磁碟和目錄，執行下載的檔案。   <br><p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.   <br><p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br><p>在该硬盘目录中，执行下载的文件。   <br><p>点击“安装”按钮进行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。   <br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2012 R2 的 HPE Intel i40ea 驅動程式"},{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2012 R2"},{"lang":"ko","x_late":"Windows Server 2012 R2용 HPE Intel i40ea 드라이버"},{"lang":"cn","x_late":"Windows Server 2012 R2版HPE Intel i40ea驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40ea64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33589455","datemodified":"2021-02-25T07:05:19","file_list":["A43_2.40_02_23_2021.signed.flash","A43_2.40_02_23_2021.xml","payload.json"],"md5sum":"52ba8a1000687b41831ca3a031bd135c","name":"A43_2.40_02_23_2021.fwpkg","release":"2021-02-25T07:01:35","revision":"0","sha1sum":"67677f647e30d43dac20a6bbd7ee1897ae458464","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"bafc8d47aead420a9621e8d49861aa9b","version":"f45774c7d9c14cc686324d8d494498f7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-09T10:08:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17395681","datemodified":"2021-01-28T12:03:46","file_list":["/CP045658_BUILD_4.data","/CP045658.vmexe","/CP045658.vmexe64","/CP045658.vmfile","/CP045658_VMw.zip","/CP045658.xml","/payload.json","/CP045658_VMw.zip/index.xml","/CP045658_VMw.zip/vendor-index.xml","/CP045658_VMw.zip/metadata.zip","/CP045658_VMw.zip/vib20/CP045658/HPE_bootbank_CP045658_HPD9.4-7.0.0.15843807.vib","/CP045658_VMw.zip/metadata.zip/vendor-index.xml","/CP045658_VMw.zip/metadata.zip/vmware.xml","/CP045658_VMw.zip/metadata.zip/vibs/CP045658-5900665137189361483.xml","/CP045658_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045658_HPD9.4-7.0.0.15843807.xml"],"md5sum":"bfa83c1923215f058557f567bdd79574","name":"CP045658.zip","release":"2021-01-28T12:01:05","revision":"0","sha1sum":"0299a67f9d7e58cfd8816cfe7c87e6e0393ce97f","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP045658","version":"HPD9.4-7.0.0.15843807"}]}],"id":{"product":"334426b326da4b9caa59be228e5282e3","version":"8c10920ef1bd45e3b231adbb71dd8182"},"installation":{"command":"CP039427.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:00:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GEQUT and MB8000GEQUU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB6000GEQUTおよびMB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPGA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3671920","datemodified":"2020-12-16T17:39:05","file_list":["cp045550.xml","cpqsetup.exe","HAHc8HaoeFGB.REL","payload.json","setup.dll"],"md5sum":"2b7394a8922a7049e8e912723d7e8331","name":"cp045550.exe","release":"2020-12-16T17:27:11","revision":"0","sha1sum":"65562d11b209ec3e1c174447e97c7ff62bedc045","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"5eebb17653054977b3ae3cbb9a44ff98","version":"f27cd93da4854484b060dd22012ce25b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:49:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.7, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 6.7用lsi-mr3コントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"110359","datemodified":"2021-02-25T06:02:55","file_list":["/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip","/cp044905.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922.vib","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vibs/lsi-mr3-8423814040991640656.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922.xml"],"md5sum":"dbbcdaf4064d3d40673c3ce9525997e6","name":"cp044905.zip","release":"2021-03-23T00:00:00","revision":"2","sha1sum":"3f0b2744b6d7a272ff45ab7e4955845f73b06f9e","size":"107KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"lsi-mr3","version":"7.716.03.00-1OEM.670.0.0.8169922"}]}],"id":{"product":"862f9bdea0634dd0aa757317bd803752","version":"d477bf04e62349f99e60465a9b526ca4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hpe/swpackages and ./hpesum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li> CD /hpe/swpackages および ./hpesum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller (64-bit) Driver for vSphere 6.7 (Driver Component)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T08:04:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-mr3:7.716.03.00-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85030G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85030G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VS000480KXALB Drive"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB Drive<br />\n <br />\n<strong>Release Version and/or Date:<br />\n      </strong>85030G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n      None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n     </strong> None</p>\n\n<p><strong>Firmware Dependency:<br />\n      </strong>None</p>\n\n<p><strong>Enhancements/New Features: </strong></p>\n\n<p>      Added Support for Windows Server 2019</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:<br />\n     </strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</p>"}],"files":[{"bytes":"5279448","datemodified":"2020-09-16T18:01:15","file_list":["85030G00_mp.bin","cp045602.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"md5sum":"57a67ff56956c814d0d577bc48f01ade","name":"cp045602.exe","release":"2020-09-16T17:52:08","revision":"0","sha1sum":"0139454b2bb0683d4b14936374274aa8381bc79e","size":"5MB","target_guids":["562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85030G00"}],"id":{"product":"15c5494e659e4865b78e60077bae7860","version":"db2c9664d02d465e84e97d4eba236106"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"SK Hynix"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:12:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added Support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_2p24_NCSIwPLDMoMCTP_800059DE.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"2.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td>\n\t\t\t<td>800059DE</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>2.24</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2839.0 includes: Intel(R) Boot Agent ICE v2.2.01 &amp; UEFI x64 100 gigabit driver v2.2.07.</p>\n"}],"files":[{"bytes":"10516427","datemodified":"2021-01-21T10:37:09","file_list":["HPE_E810_XXVDA2_SD_OCP_2p24_NCSIwPLDMoMCTP_800059DE.HPb","HPE_E810_XXVDA2_SD_OCP_2p24_NCSIwPLDMoMCTP_800059DE.xml","payload.json"],"md5sum":"5e96d586f49a5a54da3f8f153ed75a97","name":"HPE_E810_XXVDA2_SD_OCP_2p24_NCSIwPLDMoMCTP_800059DE.fwpkg","release":"2021-01-21T10:33:04","revision":"0","sha1sum":"7dc39eff4ca72de0fc3d07f3352feca3022f1882","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159b80860005"],"type_of_change":"1","version":"2.24"}],"id":{"product":"fbb53cf22a594dbb99b8c7f89e562124","version":"fa9701a0119b470cbc45b640bd256a8a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"INTEL_E810_XXV2OCP_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic FastLinQ Open-iSCSI driver for QLogic FastLinQ NICs running under SUSE Linux Enterprise Server 15 SP0."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP0で動作するQLogic FastLinQ NIC用のHPE QLogic FastLinQ Open-iSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1467524","datemodified":"2019-10-07T17:28:45","file_list":["./sbin/iscsiadm.ql","./sbin/iscsid.ql","./sbin/iscsistart.ql","./usr/share/smartupdate/qlgc-open-iscsi/component.xml"],"md5sum":"b56d3b17dae552da18f8aecefb19e9e8","name":"qlgc-open-iscsi-2.0_873.113.sles15sp0-1.x86_64.rpm","release":"2019-11-01T00:00:00","revision":"1","sha1sum":"151e47f4d0be101a9da18d5bd6957097ce6e7ad9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17f154d7"],"type_of_change":"0","version":"2.0-873.113-1"}],"id":{"product":"050c92fea0f045599773c67729354d3b","version":"647888da476047b4b4689fc09e488159"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package&nbsp;provided by&nbsp;this product is a&nbsp;pre-compiled kernel module driver&nbsp;built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp;HPE has tested and approved this&nbsp;pre-compiled kernel module RPM&nbsp;for use with the specified kernel.&nbsp;</p>\n\n<p>This pre-compiled RPM package&nbsp;may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。 HPEは、このコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>このコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Open-iSCSI Driver for SUSE Linux Enterprise Server 15 SP0"},{"lang":"ja","x_late":"HPE QLogic FastLinQ Open-iSCSIドライバー for SUSE Linux Enterprise Server 15 SP0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-12T21:55:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product no longer supports Synergy servers and devices. Synergy servers and devices are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-665f7d608e84429d87b3a76e7d\">HPE Synergy QLogic FastLinQ Open-iSCSI Driver for SUSE Linux Enterprise Server 15 SP0</a>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"qlgc-open-iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.5."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.7.20.</p>\n"}],"files":[{"bytes":"333896","datemodified":"2019-10-24T14:37:12","file_list":["/cp039952.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/ixgben-1.7.20-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/doc/README.txt","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/doc/release_note_ixgben_1.7.20-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/index.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/vendor-index.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/metadata.zip","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/vib20/ixgben/INT_bootbank_ixgben_1.7.20-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-ixgben-1.7.20.xml","/VMW-ESX-6.0.0-ixgben-1.7.20-14161312.zip/VMW-ESX-6.0.0-ixgben-1.7.20-offline_bundle-14161312.zip/metadata.zip/vibs/ixgben-8450087975139761891.xml"],"md5sum":"45065566b8c872253456a39086fc5251","name":"cp039952.zip","release":"2019-10-24T19:37:14","revision":"0","sha1sum":"6bc1354e38a88c5261e1c178c4feac522f7a0210","size":"326KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"ixgben","version":"1.7.20-1OEM.600.0.0.2768847"}]}],"id":{"product":"7c150c6f26c6491f9b995cd907650c31","version":"b3201d62efc640b6ac6d2654a82d8e1c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.7.20-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104253","datemodified":"2021-03-08T17:58:47","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"029820d67e00296b2b6d2b933bb4ae7d","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-03-08T17:52:16","revision":"0","sha1sum":"9c603ba94c53f3199af0100f3af3adcb64a60a3b","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104335","datemodified":"2021-03-08T18:01:42","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"d0dc357d8dc8e1602a3e0a1d95af171a","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-03-08T17:52:16","revision":"0","sha1sum":"fe96eedadbf384239f8edc6cb246edf759659de7","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"37f4d88a2594441eb8937501d8ada85b","version":"824d598247334d6f9671f06ca6b53baa"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3734560","datemodified":"2020-12-17T09:03:35","file_list":["cp045512.xml","cpqsetup.exe","HBCMSssseFD2.rel","payload.json","setup.dll"],"md5sum":"a1beeac42960fe651bca55d8eb51f854","name":"cp045512.exe","release":"2020-12-17T08:43:08","revision":"0","sha1sum":"16a26679a2fa948b19097db9c812bc049506bc4f","size":"3MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"ae8b95207bc948489c851dd62c16f373","version":"419acecd87774070a8ee0e9e4def2780"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:36:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK73H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK73H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK73H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK73H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK73H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK73H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK73H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7682960","datemodified":"2021-01-23T12:54:53","file_list":["cp046469.xml","cpqsetup.exe","MPK73H5Q.REL","payload.json","setup.dll"],"md5sum":"b083f3e47169973af0b2420a656426ae","name":"cp046469.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"19f15fc2637fd7c3eaff5348765e731cdcc0efb5","size":"7MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"1","version":"MPK73H5Q"}],"id":{"product":"459b31cbafbe408eaf0a96421248c984","version":"8450ccd328854ea9809a2a03127483cc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-0ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T07:36:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1147928","datemodified":"2020-06-02T18:31:07","file_list":["cp042028.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"7f879ff36f92c7ca950dbb968753f837","name":"cp042028.exe","release":"2020-06-02T18:17:25","revision":"0","sha1sum":"c46fd80ff3b27dc40f7133bba49d137716c95cb2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"d7031a8852f2411096f049c632e0a499","version":"7cbc4402f8ac416295139293310220ee"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>       None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>       </strong>None.</p>"}],"files":[{"bytes":"3625752","datemodified":"2020-12-17T13:24:51","file_list":["cp045497.xml","cpqsetup.exe","HCFLRCD5.rel","payload.json","setup.dll"],"md5sum":"538d6147f005ca1e0eb43f637ac8e8e8","name":"cp045497.exe","release":"2020-12-17T13:17:09","revision":"0","sha1sum":"e860f8a4d16b19f605fa885835f7eec909b87075","size":"3MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"5d9285c19f4844c191173be5431c0cba","version":"41764e46de834faeba4da5c0e5ad3fbd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:31:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1559632","datemodified":"2021-01-27T08:52:11","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/compat","./lib/modules/4.12.14-195-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-195-default/updates/drivers","./lib/modules/4.12.14-195-default/updates/drivers/infiniband","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-195-default/updates/drivers/net","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-195-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host","./lib/modules/4.12.14-195-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target","./lib/modules/4.12.14-195-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-195-default/updates/net","./lib/modules/4.12.14-195-default/updates/net/9p","./lib/modules/4.12.14-195-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/rds","./lib/modules/4.12.14-195-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-195-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"43e99c75f43ce125da296323155dc356","name":"mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_195-OFED.5.2.1.0.4.1.sles15sp1.x86_64.rpm","release":"2021-01-27T06:58:04","revision":"0","sha1sum":"06dc484465986e394c4f876c6c48835caa8022d9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1299198","datemodified":"2021-01-27T08:39:02","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/rdma-set-sriov-vf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.2.2","./usr/share/doc/packages/libvma-9.2.2/README.txt","./usr/share/doc/packages/libvma-9.2.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.2.2/journal.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"baff2f9cccccd249ee2a35035c0dba36","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles15sp1.x86_64.rpm","release":"2021-01-27T06:58:04","revision":"0","sha1sum":"ef7c9b0ba2f98f98d401f0c12bffbef62710c29c","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"066e9dcf95574ff7928a5c7761b7f85a","version":"4fb63509eede447fa8ac3863859c9e23"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.</p>\n\n<p>To install or upgrade the driver:<br />\nIf using 4.12.14-195-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles15sp1.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_195-OFED.5.2.1.0.4.1.sles15sp1.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP1 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP1（AMD64/EM64T）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Linux (x64) -&nbsp;HPE&nbsp;Smart Array P824i-p MR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0043(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</li>\n</ul>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名</strong><strong>：</strong><br />\n     オンラインROM Flashコンポーネントfor Linux (x64) - HPE SmartアレイP824i-p MR Gen10<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n    24.23.0-0043(A)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n    24.23.0-0042<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n    24.23.0-0042<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n    なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>Apollo 4510システムのサポートを追加しました</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>過熱の問題は、>=60Cしきい値のための誤ったIMLでした。新しいバージョンでしきい値を>65Cに変更しました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"6775825","datemodified":"2020-08-27T14:10:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/CP045234.xml","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/MR_FW_3324_4MB.rom.fw","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045234.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045234.scexe"],"md5sum":"73a8ef7bb7e26e62eaaf7ed08d15bf68","name":"firmware-cafee9b6e4-24.23.0_0043-2.1.x86_64.rpm","release":"2020-08-27T13:55:04","revision":"0","sha1sum":"f0d968021872eefdc3970e344b3ceeb648e8b9c9","size":"6MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"1","version":"24.23.0-0043"}],"id":{"product":"e9e3449278f14c8cb84369f1b3996ad4","version":"b3774521b9e04341be6ae0de58dfc045"},"installation":{"command":"CP045234.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The actual name of the &#39;firmware-smartarray-cafee9b6e4-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute following commands:\n\t<ul>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the log file, located in the current directory</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-cafee9b6e4-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the log file, located in the&nbsp;current directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>'firmware-smartarray-cafee9b6e4-*'フォルダーの実際の名前は、最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドを実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*'ロケーションに<em>./setup</em> を追加してください。</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、現在のディレクトリにあるログファイルに保存されます</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*'ロケーションに移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-cafee9b6e4-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、現在のディレクトリにあるログファイルに保存されます</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-14T09:38:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00101958en_us\" style=\"color:#0563c1; text-decoration:underline\">a00101958en_us</a></p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.2.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1532576","datemodified":"2021-01-22T10:03:15","file_list":["cp044786.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"07734c54c625bc12b208bf6c3a2967de","name":"cp044786.exe","release":"2021-01-22T09:59:06","revision":"0","sha1sum":"9934d0ecbc1fdd985cf7aff9f8ebde52af89b19f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.2.20"}],"id":{"product":"228e6aefb0ce46a0a7e230319e326d29","version":"4d952a6acb074ecb9900f4d6f3b7bd27"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version 9.4.1.20</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version 9.4.2.20</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedentv, version&nbsp;3.11.31.0</li>\n\t<li>qedrntv, version&nbsp;3.11.31.0</li>\n\t<li>qedf, version&nbsp;2.2.39.0</li>\n\t<li>qedi,&nbsp;version 2.19.36.0</li>\n</ul>\n"}],"files":[{"bytes":"6201937","datemodified":"2021-01-18T03:31:25","file_list":["/cp044977.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.31.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vib20/qedf/QLC_bootbank_qedf_2.2.39.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vib20/qedi/QLC_bootbank_qedi_2.19.36.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vib20/qedentv-ens/QLC_bootbank_qedentv-ens_3.11.31.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.31.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vibs/qedrntv--8862214620422234608.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vibs/qedf-5070258704480585441.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vibs/qedi-3524834992069333404.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vibs/qedentv-ens-7952516883410437302.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/vibs/qedentv-285223379036076759.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922-offline_bundle-17320613.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_4.0.245.0-1OEM.670.0.0.8169922.xml"],"md5sum":"2d9d8945ac1be2ff0a6eb35d446fc27f","name":"cp044977.zip","release":"2021-01-18T03:30:04","revision":"0","sha1sum":"4e929cd9e235834630dc6e4badcc827c950bcee3","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec5fbcae5e","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qedrntv","version":"3.11.31.0-1OEM.670.0.0.8169922"},{"name":"qedf","version":"2.2.39.0-1OEM.670.0.0.8169922"},{"name":"qedi","version":"2.19.36.0-1OEM.670.0.0.8169922"},{"name":"qedentv-ens","version":"3.11.31.0-1OEM.670.0.0.8169922"},{"name":"qedentv","version":"3.11.31.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"2f321a74cb604b5798705f3942acaadd","version":"eec30bdcf1c449d1a21e206365c868f4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Logging packet drops and queue allocation entries in OS log. Interrupt was received on a secondary RSS queue fp before enabling net poll. Due to that netpoll routine was not scheduled. The change is to update IGU indices and enable the interrupt if such a condition arises.</li>\n\t<li>This product addresses an iSCSI storage connection issues about the storage system receiving out of order packets from the iSCSI driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen on systems operating in a complicated VLAN environment.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qedf:2.2.39.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.31.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv-ens:3.11.31.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.11.31.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedi:2.19.36.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.44_11_13_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.44 (11/13/2020)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17475059","datemodified":"2020-11-18T02:41:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/A41_2.44_11_13_2020.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/CP046097.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.44_2020_11_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046097.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046097.scexe"],"md5sum":"10e3b3bcdb9873bfc62b998626c1ae86","name":"firmware-system-a41-2.44_2020_11_13-1.1.x86_64.rpm","release":"2020-11-18T02:33:06","revision":"0","sha1sum":"a8c3b00684fe6ab459f04a71bcc14351ad3a62d4","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"2.44_11-13-2020"}],"id":{"product":"d152e4f9638d4a6a962a3424ad625ef5","version":"8bc0969a54934136bbdc4140c0100be2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL325 Gen10 (A41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T02:33:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. </p><p>Added support to increase the maximum amount of system memory to 8TB.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed a rare issue where the system may fail to boot after a warm reset.</p><p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p><p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11616176","datemodified":"2021-01-28T10:06:34","file_list":["cp046614.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_2.42_01_23_2021.signed.flash"],"md5sum":"58dc145574be470b07db8f641eac60aa","name":"cp046614.exe","release":"2021-01-28T10:02:15","revision":"0","sha1sum":"e659135517726b15c1cccbd0717e53bee93d2211","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","version":"752b27a97c004385af78833ed5af4ab7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的線上 ROM 更新元件 - HPE ProLiant DL380 Gen10 (U30) 伺服器"},{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ko","x_late":"Windows x64용 온라인 ROM 플래시 구성 요소 - HPE ProLiant DL380 Gen10 (U30) 서버"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL380 Gen10 (U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:14:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"12822427","datemodified":"2020-11-10T11:21:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/CP044765.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/elxflashStandalone-linux-12.8.352.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/firmware/A12835212.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.02.01-1.13/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044765.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044765.scexe"],"md5sum":"43439da5978f1e9ee884cac6f0ca3a7f","name":"firmware-fc-mezz-emulex-2021.02.01-1.13.x86_64.rpm","release":"2020-11-10T11:12:05","revision":"0","sha1sum":"d7e8a5f688184c21f66a8aa54e1db73ecf0573d4","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"e498500c87604ddabe3d9c5c037f53fc","version":"a24e504d63ba497f8869e7abcbfc2968"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>12.60a4</td>\n\t\t\t<td>2.10X6</td>\n\t\t\t<td>12.6.284.0</td>\n\t\t\t<td>12.6.302.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.7</td>\n\t\t\t<td>12.6.271.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34211400","datemodified":"2021-02-25T07:08:47","file_list":["A43_2.40_02_23_2021.signed.flash","cp044523.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"9258f5d4e625b450823ff734a677af5d","name":"cp044523.exe","release":"2021-02-25T07:07:03","revision":"0","sha1sum":"005165c0e253ab8255857be6ef51f48e94c461ae","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"707f07cb4d404d119f2788d168e17586","version":"d18989e4262848e688d75fee7c7172aa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-09T10:00:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含可升級 HPE ProLiant Broadcom NX1 Gigabit 乙太網路網路卡啟動碼、PXE、UEFI、NCSI 及 CCM 碼的公用程式與二進位檔，適用於 Linux x86_64。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, and CCM code running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE ProLiant Broadcom NX1 기가비트 이더넷 NIC 부팅 코드, PXE, UEFI, NCSI 및 CCM 코드를 업그레이드하기 위한 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包内含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE ProLiant Broadcom NX1千兆以太网卡启动代码、PXE、UEFI、NCSI和CCM代码。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v20.18.31&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>NCSI Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td>\n\t\t\t<td>2.10</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331FLR Adapter<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331T Adapter</td>\n\t\t\t<td>1.46</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />\n\t\t\tHPE Ethernet 1Gb 2-port 332T Adapter</td>\n\t\t\t<td>1.40</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.27</td>\n\t\t\t<td>21.6.12</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"4256442","datemodified":"2021-01-21T07:56:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CP045012.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CP045012.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/CPINIT","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.27.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045012.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045012.scexe"],"md5sum":"0663883a1e3c8d3ad18c560b118d32b8","name":"firmware-nic-broadcom-2.27.6-1.1.x86_64.rpm","release":"2021-01-21T07:43:06","revision":"0","sha1sum":"4b706b3bed12ed777070417c8955dafe7ff43567","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"2.27.6"}],"id":{"product":"bf3a285848ac4632b8eb3d00276b79b4","version":"3b7a3d2719434e0abdc9438ebd3ca680"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP045012.txt file.The results of the firmware upgrade are saved&nbsp;in CP045012.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"Linux x86_64版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC, and VO2000KEFJD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online NVMe SSD Flash Component for Windows (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:<br />\n   </strong>  Added support for Windows 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2866304","datemodified":"2021-04-07T16:25:56","file_list":["4IFDHPK4.rel","cp045579.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"710ce0f8ad6e1f5f8ee93ed199637d3a","name":"cp045579.exe","release":"2021-04-07T16:18:07","revision":"0","sha1sum":"bb543b03065077b5419e6449b9433b572b60adbe","size":"2MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"e54bd80d86eb48638f965cd122dd00a1","version":"518561b6ed2a4860845f87fcb34eb25f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:01:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.5"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.6.</p>\n"}],"files":[{"bytes":"444333","datemodified":"2020-06-02T18:53:12","file_list":["/cp042675.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/i40en-1.10.6-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/doc/README.txt","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/doc/release_note_i40en_1.10.6-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/vib20/i40en/INT_bootbank_i40en_1.10.6-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-i40en-1.10.6.xml","/VMW-ESX-6.5.0-i40en-1.10.6-15517381.zip/VMW-ESX-6.5.0-i40en-1.10.6-offline_bundle-15517381.zip/metadata.zip/vibs/i40en--6236398258338039496.xml"],"md5sum":"f3efdc2c097f3da1aa692b32e40b20a9","name":"cp042675.zip","release":"2020-06-02T18:52:06","revision":"0","sha1sum":"1578f352054fd4b2e34039d50a3f7537a5b6c042","size":"433KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"i40en","version":"1.10.6-1OEM.650.0.0.4598673"}]}],"id":{"product":"68498f6599c54afbbc323dc39761e931","version":"cbf3b7bbbdd44bdc823667f19b4d8c65"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel i40enドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where VLAN tag traffic dropped problem.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which PCI device information passing to intnetcli Command-Line Interface (Intel&reg; ESXCLI Plug-In Managing tool ).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"}],"sw_keys":[{"name":"i40en:1.10.6-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB001000GWCBCおよびMB002000GWCBDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)-&nbsp;&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5864683","datemodified":"2020-12-13T09:03:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/CP045404.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/WRN620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045404.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045404.scexe"],"md5sum":"40662f6f16a4b41926725af2587edfba","name":"firmware-hdd-68b12e54d2-HPG6-5.1.x86_64.rpm","release":"2020-12-13T08:49:04","revision":"0","sha1sum":"0963331cc56570bc06994637fd2d3d9f31b6ab10","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c41c6d23d08b454ca2ee1c24f966683f","version":"be183c1fa427445d94c448298aefd7d5"},"installation":{"command":"CP040777.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWCBC and MB002000GWCBD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 8 x86_64."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7 Update 8 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"24868","datemodified":"2021-02-11T00:27:38","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"eb14e67cd23e7263de189f1f945decea","name":"libbnxt_re-218.0.7.0-rhel7u8.x86_64.rpm","release":"2021-02-11T00:25:06","revision":"0","sha1sum":"f509521f96563f603288148a797028fc061e0e10","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"a7b0a77ad412478f9ceb945592e1c7ab","version":"1214929690b34642a3e2d23b205788ee"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 Update 8用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD3"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB002000JWFVN and MB004000JWFVP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB002000JWFVNおよびMB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4861157","datemodified":"2020-12-13T09:22:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/CP045406.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/TATCATRsnSD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045406.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045406.scexe"],"md5sum":"872a1d3a3606eaa71a2e9aba6d226d20","name":"firmware-hdd-d7af557f47-HPD3-3.1.x86_64.rpm","release":"2020-12-13T09:10:04","revision":"0","sha1sum":"5ccb0f3f603c28a878a643d0f20af0037890b73a","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"f1e144df7ff3445292cda5ea1ed9d30c","version":"b754509b00854600952fa928c0f76e08"},"installation":{"command":"CP041753.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB002000JWFVN and MB004000JWFVP Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG2"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG2"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG2"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG2"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG2"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16380800","datemodified":"2021-01-28T12:32:58","file_list":["/CP045682_BUILD_3.data","/CP045682.vmexe","/CP045682.vmexe64","/CP045682.vmfile","/CP045682_VMw.zip","/CP045682.xml","/payload.json","/CP045682_VMw.zip/index.xml","/CP045682_VMw.zip/vendor-index.xml","/CP045682_VMw.zip/metadata.zip","/CP045682_VMw.zip/vib20/CP045682/HPE_bootbank_CP045682_HPG2.3-7.0.0.15843807.vib","/CP045682_VMw.zip/metadata.zip/vendor-index.xml","/CP045682_VMw.zip/metadata.zip/vmware.xml","/CP045682_VMw.zip/metadata.zip/vibs/CP045682--9140416863122666815.xml","/CP045682_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045682_HPG2.3-7.0.0.15843807.xml"],"md5sum":"2933efc83fdb71137875d263df6eeeff","name":"CP045682.zip","release":"2021-01-28T12:29:05","revision":"0","sha1sum":"970852bbe69b92696d655ce06606f2a07c8b5455","size":"15MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045682","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"f7ead10dcb9d4e3b81c19da679b23ce2","version":"5f0fea338d4c448ead6b351c9cb76f97"},"installation":{"command":"CP040788.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:19:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD6"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD6"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5622167","datemodified":"2020-12-13T08:39:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/CP046266.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/SKESTND6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046266.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046266.scexe"],"md5sum":"ce39f6ad45653c15c2e637de3fc5ac64","name":"firmware-hdd-3d97759111-HPD6-2.1.x86_64.rpm","release":"2020-12-13T08:26:08","revision":"0","sha1sum":"7af0f8304c06e02ba0edea2ba719610ed24f3f2e","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"eca7d77c8ba84ffe9014dfb5c3b6ee15","version":"b4e5832486774e46bead24a86561c640"},"installation":{"command":"CP040309.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000300JWCPK、EH000600JWCPLおよびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-12T17:05:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.8.7.</p>\n"}],"files":[{"bytes":"398162","datemodified":"2020-06-02T18:58:09","file_list":["/cp042679.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/ixgben-1.8.7-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/doc/README.txt","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/doc/release_note_ixgben_1.8.7-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/index.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/metadata.zip","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/vib20/ixgben/INT_bootbank_ixgben_1.8.7-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-ixgben-1.8.7.xml","/VMW-ESX-6.5.0-ixgben-1.8.7-15416394.zip/VMW-ESX-6.5.0-ixgben-1.8.7-offline_bundle-15416394.zip/metadata.zip/vibs/ixgben-9095492601744696657.xml"],"md5sum":"a41bb4b6fcb0582d6f33f9d722670f65","name":"cp042679.zip","release":"2020-06-02T18:57:04","revision":"0","sha1sum":"8091e34ad1b2d52c04ac24ec62896ea365425f2d","size":"388KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"ixgben","version":"1.8.7-1OEM.650.0.0.4598673"}]}],"id":{"product":"a6351a56dbe64b13b1076909ea7de13e","version":"11fc7846ce694bff8c0a8309c3b41ce6"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product corrects a recursion termination condition so that recursion correctly ends in the case of PCIe link down.<br />\nThis product addresses an issue where the ixgben driver has high CPU overhead when an SFP+ module is absent.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which notification from Link Partner when executed Link Flow Control settings.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.8.7-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD3"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP and EG001200JWJNQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>    </strong> None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4071600","datemodified":"2020-12-17T13:48:21","file_list":["cp045493.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ND3.rel"],"md5sum":"75195c18a0523ab4a73897a7c1b163ea","name":"cp045493.exe","release":"2020-12-17T13:40:08","revision":"0","sha1sum":"332ecebf32cd9a46b2426e94bd0527e982b69845","size":"3MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5ac3ee90b2184fa9828f960cd9d17840","version":"3231804b5e184f74a40d707bfd8b7a44"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP and EG001200JWJNQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:29:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用のQLogicドライバー"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1543450","datemodified":"2021-01-22T08:47:54","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp044777.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"1ef95cf1f30003889f464ba23cf6734b","name":"cp044777.zip","release":"2021-01-22T08:47:08","revision":"0","sha1sum":"ef0bb00dae52f90de9a893826dfc76f8eadd3fac","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"8c8abb08e5a24556bd3dc3dfd7b5528b","version":"1dc592b4cd674e16b740b2b2068edf42"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Driver version 2.1.101.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB2000JFEML and MB4000JFEMN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB2000JFEMLおよびMB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5475763","datemodified":"2020-12-13T13:27:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/CP045431.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/HAKPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045431.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045431.scexe"],"md5sum":"d1030a9a626a2fbe5b87d79c1d07323a","name":"firmware-hdd-624b75c7e2-HPD6-7.1.x86_64.rpm","release":"2020-12-13T13:15:06","revision":"0","sha1sum":"29eba396605428aa2d89faa5d7387af303bd8fb0","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"e3c28d7e84d2418a888d50f48b760538","version":"5cef0589ea3d4592954cf710966f0216"},"installation":{"command":"CP040328.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2019用HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1026624","datemodified":"2021-01-14T07:14:35","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045021.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"0b4e87269f0b0842d74425c0733cf7ea","name":"cp045021.exe","release":"2021-01-14T06:59:05","revision":"0","sha1sum":"c7917e0657fba322d32c6cd645a36aecafedf7c9","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"dd64dbafe6064086a1f60841a460f8b0","version":"adc9ee2cc1df4db187d5224df9c5b239"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which live firmware upgrade fails when run on both interfaces of the adapter simultaneously.</li>\n\t<li>This product corrects a timeout issue which configures network connection.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes BSOD observed after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel over Ethernet Driver kit for HPE Storage Emulex(BRCM) Converged Network Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1153321","datemodified":"2021-01-22T04:56:56","file_list":["/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip","/cp042522.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/brcmfcoe-12.0.1278.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/doc/README.txt","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/doc/release_note_brcmfcoe_12.0.1278.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/vendor-index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/vib20/brcmfcoe/EMU_bootbank_brcmfcoe_12.0.1278.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vibs/brcmfcoe-5045933561286143092.xml"],"md5sum":"927912f82a52f8eb13147d25d934f6e7","name":"cp042522.zip","release":"2021-01-22T04:56:05","revision":"0","sha1sum":"97a001f263db81b8a4ca36b3ee02798fe8d14e61","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2e31a109"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmfcoe","version":"12.0.1278.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"ddd8d308b4884fcca8742e3dd4152801","version":"b420e9557eb245d8be878dad4bfc1da3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex(BRCM) Fibre Channel over Ethernet driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:27:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1278.0</p>\n","latest_fixes_x_late":"<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<p>Fixed the following:</p>\n\n\t\t\t<ul>\n\t\t\t\t<li>Purple Screen of Death(PSOD) at random intervals on HPE FlexFabric 20Gb 2-port 650FLB Adapter</li>\n\t\t\t\t<li>Link down after 1000 times port down and up iterations on switch.</li>\n\t\t\t\t<li>Detaching is not completing because lpfc_do_work_event can&#39;t exit.</li>\n\t\t\t\t<li>Slab memory use after free causing memory leak.</li>\n\t\t\t\t<li>Small Computer Sytem Interface(SCSI) command is used after done call.</li>\n\t\t\t\t<li>Target reset does not report original status</li>\n\t\t\t</ul>\n\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\n\t\t\t<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex&nbsp;XE-102 Based&nbsp;Network Adapters May Experience Link Down Due Toa&nbsp;Firmware Issue&quot; at the following&nbsp;link:</p>\n\n\t\t\t<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>&nbsp;</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1278.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe:12.0.1278.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel NVMe Driver kit for HPE Storage Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"39081","datemodified":"2020-10-13T18:01:16","file_list":["/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip","/cp045823.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/vib20/brcmnvmefc/EMU_bootbank_brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vmware.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/vibs/brcmnvmefc--8683936915530851429.xml","/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807_16963846.zip/metadata.zip/bulletins/Broadcom-ELX-brcmnvmefc_12.8.329.0-1OEM.700.1.0.15843807.xml"],"md5sum":"ab6a9e3145bfbb4fd65a6364a69fa7d3","name":"cp045823.zip","release":"2020-10-13T18:00:06","revision":"0","sha1sum":"0e57e48853dbe62bd6b90c078ea92800b56bc67d","size":"38KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccf06fbb4","20a6e8e4-bf33-4c71-a6bf-d9ec8e5a330c"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmnvmefc","version":"12.8.329.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"3e859f26085e4c19bd96948c814343e5","version":"b7f64a9dbeff4d4292bcdafa0e2b4dfc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel NVMe driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-02T09:09:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.329.0</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"brcmnvmefc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-ELX-brcmnvmefc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5662944","datemodified":"2020-12-18T02:18:43","file_list":["SignedImageInstaller64.dll","U22_2.90_11_27_2020.signed.flash","cp046424.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"4c9803a27cebc8350687025e23588a2b","name":"cp046424.exe","release":"2020-12-18T02:01:35","revision":"0","sha1sum":"cc29247a28235dd75540c2dc43d27eca54715623","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020"}],"id":{"product":"b2f966fef439400c8d3f8bcc5b3de93f","version":"5f2fba0cb9af4d64a01d4c3d061c7866"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:09:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR416i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-p_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7490140","datemodified":"2021-02-25T05:38:59","file_list":["HPE_MR416i-p_Gen10P_52.16.3-3913.ilo","HPE_MR416i-p_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"1f1764e9d89f8989bc50a6644c0eb4a5","name":"HPE_MR416i-p_Gen10P_52.16.3-3913.fwpkg","release":"2021-03-22T00:00:00","revision":"1","sha1sum":"ec6c67d44f430d3f11f1abb18c85c28133b08393","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e215900293"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"3f857d7b01734aa494f8146516002d2e","version":"f12ce7d5927c40098d1350b8bc390d2b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p Gen10 Plus Tri Mode Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-27T13:21:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"02931590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter and Mezzanine Host Bus Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2278058","datemodified":"2021-01-22T05:20:29","file_list":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ia32.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64-64bit.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"md5sum":"3300896aaf53ef1a53ce446f676cb54e","name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.0-16.noarch.rpm","release":"2021-01-22T05:16:43","revision":"0","sha1sum":"ed4987297444dd841c8c65712dbdc74b729f0046","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"type_of_change":"1","version":"6.0.0.0-16"}],"id":{"product":"d1422347af3f4f888596c242a7fdb7a6","version":"48b08e042e66490ba1807d71a2c1917a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 12 service pack&nbsp;4 and SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;1 and SuSE Linux Enterprise Server 15 service pack&nbsp;2 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel Enablement Kit for QLogic Host Bus Adapter and Mezzanine Host Bus Adapter for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated the kit to version 6.0.0.0-13</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated the kit to version 6.0.0.0-16</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MK000240GWCEU、MK000480GWCEV、MK000960GWCFA、およびMK001920GWCFB "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and&nbsp;MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15691621","datemodified":"2021-01-28T08:41:07","file_list":["/CP045669_BUILD_3.data","/CP045669.vmexe","/CP045669.vmexe64","/CP045669.vmfile","/CP045669_VMw.zip","/CP045669.xml","/payload.json","/CP045669_VMw.zip/index.xml","/CP045669_VMw.zip/vendor-index.xml","/CP045669_VMw.zip/metadata.zip","/CP045669_VMw.zip/vib20/CP045669/HPE_bootbank_CP045669_HPG3.3-7.0.0.15843807.vib","/CP045669_VMw.zip/metadata.zip/vendor-index.xml","/CP045669_VMw.zip/metadata.zip/vmware.xml","/CP045669_VMw.zip/metadata.zip/vibs/CP045669--5025988151474843833.xml","/CP045669_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045669_HPG3.3-7.0.0.15843807.xml"],"md5sum":"d50ff2fb8252cd0e1eb7509875b3db92","name":"CP045669.zip","release":"2021-01-28T08:38:06","revision":"0","sha1sum":"394c739a8d75f352b465eba6a030bcc58de9559e","size":"14MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP045669","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"568141f535e3461e90494d5ac58c3991","version":"baf64209b7b64769add010e5281acfc1"},"installation":{"command":"CP040679.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:09:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.20"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.20"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10 NVMe storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"621616","datemodified":"2018-10-11T23:52:23","file_list":["cp037722.xml","cpqsetup.exe","ISS_NVMe_BP_PIC_flashV1B20_signed.hex","payload.json","SecureFlash64.dll"],"md5sum":"3a19b885a3da0f887ba3529338b58df8","name":"cp037722.exe","release":"2018-10-12T04:50:03","revision":"0","sha1sum":"cc6dd7e04377366b0ca01e68b5a1e4c4dd8e6705","size":"607KB","target_guids":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"type_of_change":"0","version":"1.20"}],"id":{"product":"028a309bf839487ca2355a0eed9d368b","version":"4bc70c2144b342688bb197912df80aae"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\">Service Pack for ProLiant&nbsp;</a><strong>:</strong></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hp.com/go/spp\" style=\"text-decoration: none; color: blue;\">HPE Service Pack for ProLiant</a><strong>から以下の手順に従ってください：</strong></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるStart.htmlを特定します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10 NVMe Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10 NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"00000000-0000-0000-0000-00004e564d65","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-27T08:48:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">The following support was added in version 1.20(B). No new features were added in version 1.20(C).</p>\n\n<ul>\n\t<li style=\"margin-left: 0in; margin-right: 0in;\">Added support for the HPE ProLiant XL270d Gen10 Server</li>\n</ul>\n","latest_fixes_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Firmware Package version 1.20(C) addressed the following issue:</p>\n\n<ul>\n\t<li>When using OneView, attempts to upgrade firmware from version 1.18 to 1.20 failed.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Note: If the target device was previously updated to firmware version 1.20, it is not necessary to apply firmware update 1.20(C).</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server (private)"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server (private)"}],"sw_keys":[{"name":"NVMePIC-Gen10","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7310496","datemodified":"2021-01-08T13:46:41","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"504d1400b0dae3f7dd01ce59e4935749","name":"netxtreme2-kmp-default-7.14.76_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-08T13:22:05","revision":"0","sha1sum":"d29ab64027df5fa573f4b9d33326febb72f0908b","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"6882030","datemodified":"2021-01-08T13:52:36","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/bnx2.ko","./lib/modules/4.12.14-195-default/updates/bnx2fc.ko","./lib/modules/4.12.14-195-default/updates/bnx2i.ko","./lib/modules/4.12.14-195-default/updates/bnx2x.ko","./lib/modules/4.12.14-195-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"53f82d3afd1b1613d47fcc63bfcdf14d","name":"netxtreme2-kmp-default-7.14.76_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-08T13:22:05","revision":"0","sha1sum":"ca51648c288d5e7a070d7b604100bb6416511aa6","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"eafab624995d485096ba1119b617b464","version":"4410078eacad40a4acceca8299e4d26e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the driver Precision Time Protocol (PTP) is not working due to timestamp problem.</li>\n\t<li>This product addresses an issue where the Firmware installation failure when enabling secure boot under SUSE Linux Enterprise Server 15 SP2.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"85506","datemodified":"2021-01-09T01:32:09","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"f41f59ae92f94dbd35cfd0c9aa657a52","name":"kmod-hp-iavf-4.0.2-1.rhel8u3.x86_64.rpm","release":"2021-01-09T01:17:05","revision":"0","sha1sum":"8dcd54e4694eb5aef1c0b1f3b3718f178bed9d2c","size":"83KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.0.2-1"},{"bytes":"85511","datemodified":"2021-01-09T01:26:58","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"10447504258314797526e07be3bed8af","name":"kmod-hp-iavf-4.0.2-1.rhel8u2.x86_64.rpm","release":"2021-01-09T01:17:05","revision":"0","sha1sum":"6b28aad91a5987e480f7aafbb40613660a5b27e9","size":"83KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.0.2-1"}],"id":{"product":"26d6bb7ca1354a5998790d5fa42f5aa8","version":"2d03bf73d124449591b65448d69d064d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel iavf ドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<p>&nbsp;</p>\n\n<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-364875f2e83b","Version":"4H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-324808558bd9","Version":"4H3Q"},{"DeviceName":"MZPLJ6T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448edb4b867","Version":"4H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version is now available from the following OS-specific URLs: VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2 Linux: EPK74H3Q\nFirmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp; </strong>4H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"9364192","datemodified":"2021-01-23T12:09:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/CP046697.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/EPK74H3Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-4H3Q-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046697.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046697.scexe"],"md5sum":"5937e8af357df256c3598e5999b0810c","name":"firmware-hdd-6628fce235-4H3Q-2.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"e53c64302cd07868d8bde6961b4fa58ff24b5b1f","size":"8MB","target_guids":["4d2340a5-505a-4a4c-3154-364875f2e83b","4d2340a5-505a-4a4c-3354-324808558bd9","4d2340a5-505a-4a4c-3654-3448edb4b867"],"type_of_change":"1","version":"4H3Q"}],"id":{"product":"77f2ff3d7ebf4999a5ec47887c09ecdf","version":"a70df140a87a4729bf2d79df32ade2a3"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"},{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:12:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version&nbsp; is now available from the following OS-specific URLs:</p>\n\n<p>VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac</p>\n\n<p>Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2</p>\n\n<p>Linux: EPK74H3Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a</p>\n\n<p>Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000</p>\n\n<p>Working version EPK74H3Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: VK000240GWCFD ,VK000480GWCFE ,VK000960GWCFF ,VK001920GWCFH and VK003840GWCFK "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFK "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15685447","datemodified":"2021-01-28T12:13:43","file_list":["/CP045680_BUILD_3.data","/CP045680.vmexe","/CP045680.vmexe64","/CP045680.vmfile","/CP045680_VMw.zip","/CP045680.xml","/payload.json","/CP045680_VMw.zip/index.xml","/CP045680_VMw.zip/vendor-index.xml","/CP045680_VMw.zip/metadata.zip","/CP045680_VMw.zip/vib20/CP045680/HPE_bootbank_CP045680_HPG3.3-7.0.0.15843807.vib","/CP045680_VMw.zip/metadata.zip/vendor-index.xml","/CP045680_VMw.zip/metadata.zip/vmware.xml","/CP045680_VMw.zip/metadata.zip/vibs/CP045680--8172961786630739284.xml","/CP045680_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045680_HPG3.3-7.0.0.15843807.xml"],"md5sum":"1fc94b61d3232ab7b1184b693606ea90","name":"CP045680.zip","release":"2021-01-28T12:11:04","revision":"0","sha1sum":"1a199b58e1020da2cc16b1d0a8bdca794099f58a","size":"14MB","target_guids":["562340a5-304b-3030-3234-304757434644","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP045680","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"0d1bdabb9bd2412a9e8131f41d12a1c0","version":"a5266c0b5d9142f4bb7eb3649b8300d4"},"installation":{"command":"CP040671.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK   Drives."},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFH およびVK003840GWCFK ドライブ。"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:18:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62900","datemodified":"2021-03-08T18:23:57","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"f70dba16d37671f891799ab920187bd2","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"80f15d86f74ba0e3bb6ef72741c6d6f67be55769","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"62899","datemodified":"2021-03-08T18:19:39","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"3d079135a638cbf5dc430db567f12a96","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"f7ce9704b8e9ac5f9334a529626e07f2e731678d","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"5230830842514ef8a52b0b19a00fb203","version":"1fe9919da8234720accc28522b08cd41"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000GWTFEおよびMB014000GWTFFドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4872680","datemodified":"2020-12-13T12:46:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/CP046336.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/TAMG07abHPG7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046336.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046336.scexe"],"md5sum":"12e1e7ad31aed38cb1837287fa41c778","name":"firmware-hdd-b78255e146-HPG7-2.1.x86_64.rpm","release":"2020-12-13T12:35:08","revision":"0","sha1sum":"73b9b4c9061fc184e835d9ff5b84147a0e0986f2","size":"4MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"03a1d5d1c9c84f2b9c715674a729ac00","version":"7e60f2b336af4051a229f6e72805328e"},"installation":{"command":"CP042460.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWTFE and MB014000GWTFF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-24T09:56:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware revision improves low-temperature performance and Error Correction Code (ECC) error recording for some commands.&nbsp;</li>\n\t<li>It also improves internal logging capabilities for failure analysis.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2012 R2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"911816","datemodified":"2019-10-24T20:28:41","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp039930.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"37207b958cc7bfaa6d61859d18ca1aa4","name":"cp039930.exe","release":"2019-10-24T20:15:04","revision":"0","sha1sum":"4bee2c4beba3ae4a0c44bdb30dc6a8c8acd2eb6d","size":"890KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"9d59a3d1e4634bdbbc3b067cb8dad588","version":"d3e6dd33c77f4eeab871710c674fa622"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK007680GWSXNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK007680GWSXN&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4976706","datemodified":"2020-12-13T15:47:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/CP045463.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/M52008G2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045463.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045463.scexe"],"md5sum":"3bd2d52ffa98f69aa1cd85b9b226d389","name":"firmware-hdd-b460823f70-HPG2-5.1.x86_64.rpm","release":"2020-12-13T15:36:06","revision":"0","sha1sum":"26123877b9054792470941d55811c51ace49b444","size":"4MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"0c319cd0bae843d891d1e9696a4b873b","version":"25b9b7f7ff224440bf576de9bf7af015"},"installation":{"command":"CP040780.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP1."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 15 SP1下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22955","datemodified":"2021-02-11T00:35:40","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"995da5da2cbcef872a613c2ec8ce4b06","name":"libbnxt_re-218.0.7.0-sles15sp1.x86_64.rpm","release":"2021-02-11T00:33:04","revision":"0","sha1sum":"c3f3bb1743118affd235b1dc21b43ce120eed7b9","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"0edaaf6685e5406d9f15af585063acb1","version":"f52e007016ef420ab3f2755c688a470f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP1"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15 SP1用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now disables loading RoCE driver on VFs when Link Aggregation is enabled</li>\n\t<li>This product now supports rdma-core v22&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n\t<li>This product corrects an issue which HPSUM selects driver for SUSE Linux Enterprise Server 15 while SPP deployment running with SUSE Linux Enterprise Server 15 Service Pack 1 platform.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;19.12.13.0.</p>\n"}],"files":[{"bytes":"192895","datemodified":"2020-04-27T22:08:42","file_list":["/cp041297.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vib20/ixgben/INT_bootbank_ixgben_1.8.9.0-1OEM.700.1.0.15525992.vib","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vibs/ixgben-6835652811471104199.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/bulletins/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992.xml"],"md5sum":"80e7b0a884d68fdebc68c5fab7f25291","name":"cp041297.zip","release":"2020-04-28T03:08:04","revision":"0","sha1sum":"ab89f9e701326912fae243765d87050df3ed7a77","size":"188KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"0","version":"2020.05.29","vib_list":[{"name":"ixgben","version":"1.8.9.0-1OEM.700.1.0.15525992"}]}],"id":{"product":"8dc1af4f4f75416590a7ddb9bd07a92c","version":"455a9b8a38064383984f9cbbf2f0b1ff"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-02T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG2"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG2"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG2"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG2"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG2"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH, MK001920GWUGK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and&nbsp;MK001920GWUGK&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4981900","datemodified":"2020-12-13T15:20:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/CP045462.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/M5200SG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045462.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045462.scexe"],"md5sum":"a14bc1982e6280081bb6fd9b807c07fb","name":"firmware-hdd-9e87eecb3f-HPG2-5.1.x86_64.rpm","release":"2020-12-13T15:08:05","revision":"0","sha1sum":"b5b9d88c921b3f85e413749ada6aec17ac6fa3cc","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"4cc24985bf9c485084dcadb54a29cb28","version":"cb560129b67c420e86fee00842829af2"},"installation":{"command":"CP040781.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"20542","datemodified":"2021-02-09T17:02:31","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/mst_pci.ko","./lib/modules/5.3.18-22-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"967174baf214b2b1429efbd0d6c4ba64","name":"kernel-mft-mlnx-kmp-default-4.16.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-02-09T16:53:04","revision":"0","sha1sum":"37532bdbe4f2b0a5f824d20eed5597626664cf78","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"},{"bytes":"8915933","datemodified":"2021-02-09T16:59:32","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"d75f45708dd61f3b67411af1d006eda8","name":"mft-4.16.0-105.sles15sp2.x86_64.rpm","release":"2021-02-09T16:53:04","revision":"0","sha1sum":"afe2967a3959dbb22e4be70508bfaad2db9c54e1","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"}],"id":{"product":"d60ce0b82db54a2e881c0e0bf9e229a2","version":"4757bbff9d4840f29fc2f52f1011e70a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using 4.12.14-195-default kernel or any future errata:<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_195-1.sles15sp2.x86_64.rpm&nbsp;&nbsp;mft-4.16.0-105.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12983219","datemodified":"2021-01-08T13:55:41","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"98c3b9955bae2ffe9fa440a616450b38","name":"kmod-qlgc-fastlinq-8.55.5.0-1.rhel7u9.x86_64.rpm","release":"2021-01-08T13:25:05","revision":"0","sha1sum":"df7f51bbf33ddc8b8b5555a1bf05780425e406cf","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.5.0-1"},{"bytes":"12977712","datemodified":"2021-01-08T13:50:30","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"2fd6674e577bb2f3628e10f742697621","name":"kmod-qlgc-fastlinq-8.55.5.0-1.rhel7u8.x86_64.rpm","release":"2021-01-08T13:25:05","revision":"0","sha1sum":"1a38599de15b4ba01eab4d9622bcfb5bc541695e","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"0","version":"8.55.5.0-1"}],"id":{"product":"882bb8e4707345cbb8f1e7ba0901abee","version":"e8bfc60088a744dca5cc45f89ccfd0e6"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 Update 8</li>\n\t<li>This product now adds PCIe Advanced Error Recovery (AER) support</li>\n\t<li>This product now supports RoCE bonding mode</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which system crash after unloading and reloading only roce driver</li>\n\t<li>This product corrects an issue which VF RDMA system crash in overnight reboot test on multiple VMs</li>\n\t<li>This product corrects an issue which VMs crash randomly upon advanced property disable/enable with Max VFs enumerated on all PFs</li>\n\t<li>This product corrects an issue which iSCSI BFS system fails to reboot if one port is down and reboot is attempted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 update 9</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen running burnin and iperf stress in Red Hat Enterprise Linux 7 update 9 environment</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1108576","datemodified":"2020-06-02T18:10:50","file_list":["cp042027.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn64x64.cat","ixn64x64.din","ixn64x64.inf","ixn64x64.sys","ixnmsg.dll","nicco5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"dd40891fffe2386e796426c5ec2f13e3","name":"cp042027.exe","release":"2020-06-02T17:57:08","revision":"0","sha1sum":"389d1cc918647e75026376dafe93553e7227b7d5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecee44051c"],"type_of_change":"0","version":"3.14.214.0"}],"id":{"product":"bf47b80cbb5e498dbf61a3acfee47afb","version":"7ae9b65b8d1b44749c5910226b8f1041"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為一個自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br><p>從該磁碟和目錄，執行下載的檔案。   <br><p>按一下 Install (安裝) 按鈕，以繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.   <br><p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br><p>在该硬盘目录中，执行下载的文件。   <br><p>点击“安装”按钮进行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。   <br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixn64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Emulex Generic 8Gb PCI Express Fibre Channel HBA (F100)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F10010DFF100","Version":"1280A3"},{"DeviceName":"HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3281","Version":"1280A3"},{"DeviceName":"HPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3282","Version":"1280A3"},{"DeviceName":"HPE SN1000E 16Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E4","Version":"12.8.352.12"},{"DeviceName":"HPE SN1000E 16Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E5","Version":"12.8.352.12"},{"DeviceName":"HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197F","Version":"12.8.352.12"},{"DeviceName":"HPE  SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197E","Version":"12.8.352.12"},{"DeviceName":"HPE 84E 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C2238","Version":"1280A3"},{"DeviceName":"HPE SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200159000FB","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"10643870","datemodified":"2021-01-29T06:34:54","file_list":["/CP044730_BUILD_18.data","/CP044730.vmexe","/CP044730.vmexe64","/CP044730.vmfile","/CP044730_VMw.zip","/CP044730.xml","/payload.json","/CP044730_VMw.zip/index.xml","/CP044730_VMw.zip/vendor-index.xml","/CP044730_VMw.zip/metadata.zip","/CP044730_VMw.zip/vib20/CP044730/HPE_bootbank_CP044730_2021.02.01.18-7.0.0.15843807.vib","/CP044730_VMw.zip/metadata.zip/vendor-index.xml","/CP044730_VMw.zip/metadata.zip/vmware.xml","/CP044730_VMw.zip/metadata.zip/vibs/CP044730--717683143993792792.xml","/CP044730_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044730_2021.02.01.18-7.0.0.15843807.xml"],"md5sum":"440550404fe626ac10c3552f7a79ac2e","name":"CP044730.zip","release":"2021-01-29T06:31:04","revision":"0","sha1sum":"0997c282784e176f5402e2312c52b527d4c1a2cf","size":"10MB","target_guids":["a6b1a447-382a-5a4f-10DF-F10010DFF100","a6b1a447-382a-5a4f-10DF-F100103C3281","a6b1a447-382a-5a4f-10DF-F100103C3282","a6b1a447-382a-5a4f-10DF-E200103C17E4","a6b1a447-382a-5a4f-10DF-E200103C17E5","a6b1a447-382a-5a4f-10DF-E200103C197F","a6b1a447-382a-5a4f-10DF-E200103C197E","a6b1a447-382a-5a4f-10DF-F100103C2238","a6b1a447-382a-5a4f-10DF-E200159000FB","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D6","a6b1a447-382a-5a4f-10DF-F400159002D5"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044730","version":"2021.02.01.18-7.0.0.15843807"}]}],"id":{"product":"40aca5b1425544eabf3dc630ea9b775f","version":"0d11d09152ad4a06b45bf01cc7cf774b"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp; have separate components to update fibre channel and converged network adapters.&nbsp;This is a fibre channel&nbsp;update component.</p>\n\n<p><strong>Contains:</strong></p>\n\n<p>32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16/32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>8 Gb HBA Standup firmware 2.10X6<br />\n8 Gb standup universal boot image 12.60a4(12.6.302.0 BIOS, 12.6.284.0 UEFI)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2019を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1612176","datemodified":"2020-06-12T11:09:45","file_list":["bepnic.dll","bepnic.rtf","cp044542.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"3867a732a8f6d31de5b592929665fe50","name":"cp044542.exe","release":"2020-06-12T10:56:04","revision":"0","sha1sum":"2162bf360898c1fe98751a0362c0a1203bf04903","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"ee7c0fad5ff040dabc594be75871d841","version":"03f10bf622574025b711b1e94d94eee1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11467322","datemodified":"2021-01-28T10:13:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/CP046625.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/U32_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046625.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046625.scexe"],"md5sum":"6487b2544db7f88d4c5b2d0a0154c524","name":"firmware-system-u32-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T10:05:21","revision":"0","sha1sum":"cf31859ce13642e8203f91dfca135baaa0793309","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"ff5a3639b5c744a8ac2e4611ce9482ea","version":"35ead8ed7ee543bd8817968fdaa8afcc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.20 (10/27/2020)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16806940","datemodified":"2020-11-02T15:11:46","file_list":["payload.json","U48_2.20_10_27_2020.signed.flash","U48_2.20_10_27_2020.xml"],"md5sum":"454c00eaecf31e2be63196571bb2f559","name":"U48_2.20_10_27_2020.fwpkg","release":"2020-11-02T15:08:04","revision":"0","sha1sum":"449b39182907619156d8ae977cc477ba0962f9a3","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"0","version":"2.20_10-27-2020"}],"id":{"product":"b8b6b31789ce4119a48876ba4b89c81f","version":"579f55d77b1c4028bfa4f0740cc41b2d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T03:38:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode for Intel Pentium processors which provides mitigations for security vulnerabilities documented as CVE-2020-0543 as well as CVE-2020-0548 and CVE-2020-0549. These security vulnerabilities are documented in Intel Security Advisories INTEL-SA-00320 and INTEL-SA-00329. These issues are not unique to HPE servers. This update does not impact systems using Intel Xeon based processors.</p>\n\n<p>Addressed an issue where the system would become unresponsive with a Red Screen or hang when booting to FreeBSD R12.1 from a USB device when in Legacy Boot Mode. This issue did not impact systems configured for UEFI Boot Mode or when booting from other types of media.</p>\n\n<p>Addressed an issue where a dual port networking device may show up in the System Configuration Utilities with two Port 1 names instead of properly being represented as Port 1 and Port 2. This did not impact any functionality to the device.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.</p>\n\n<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n\n<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.</p>\n\n<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"cn","x_late":"软件 - 管理"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"}]}],"description":[{"lang":"en","x_late":"The HPE SMX Provider Bundle Smart Component for ESXi 7.0 includes the latest HPE Common Information Model (CIM) Providers."},{"lang":"ja","x_late":"HPE SMXプロバイダーバンドルSmartコンポーネントfor ESXi 7.0には、最新のHPE Common Information Model (CIM) プロバイダーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"21583239","datemodified":"2020-06-17T19:02:07","file_list":["/cp044591.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/vendor-index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/vib20/smx-provider/HPE_bootbank_smx-provider_700.03.16.00.12-14828939.vib","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vendor-index.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vmware.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/vibs/smx-provider--4679724045287253549.xml","/smxProvider_700.03.16.00__1_.12_14828939_signed_component_1567546.zip/metadata.zip/bulletins/smxProvider_700.03.16.00.12-14828939.xml"],"md5sum":"7dd29840fdae56a34ee2ac55fe353c9f","name":"cp044591.zip","release":"2020-06-17T19:01:11","revision":"0","sha1sum":"a647832dc7011a43a1e2186809f84327aefd3965","size":"20MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaf52c64","20a6e8e4-bf33-4c71-a6bf-d9eccb7b83b0"],"type_of_change":"1","version":"2020.04.01","vib_list":[{"name":"smx-provider","version":"700.03.16.00.12-14828939"}]}],"id":{"product":"f5ab6808fff6474c8daabc965dddfa7b","version":"f421af36cd6242e4875db001fde51cdb"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SMX Provider Bundle Smart Component for ESXi 7.0"},{"lang":"ja","x_late":"HPE SMXプロバイダーバンドルSmartコンポーネントfor ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"22000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-17T03:21:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Support for VMware ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add new supported servers</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smxProvider:700.03.16.00.12-14828939","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"smx-provider:700.03.16.00.12-14828939","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6228222","datemodified":"2020-11-05T03:49:17","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/CP046161.xml","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/P95_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p95-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046161.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046161.scexe"],"md5sum":"0ac32b532f15fcdd9944c047278bf96b","name":"firmware-system-p95-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-05T03:33:05","revision":"0","sha1sum":"796890560a07208831185427ddba6d4d8987dc33","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"13b837d640ac455ba223e985cd1fb165","version":"6c6386c9563140a6abd4fb15ea9c3b14"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML150 Gen9(P95)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T06:14:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.2829.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE\r\n\r\n","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7 and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29683969","datemodified":"2021-01-21T09:34:37","file_list":["/CP044896_BUILD_37.data","/CP044896.vmexe","/CP044896.vmexe64","/CP044896.vmfile","/CP044896_VMw.zip","/CP044896.xml","/payload.json","/CP044896_VMw.zip/index.xml","/CP044896_VMw.zip/vendor-index.xml","/CP044896_VMw.zip/metadata.zip","/CP044896_VMw.zip/vib20/CP044896/HPE_bootbank_CP044896_3.15.8.37-7.0.0.15843807.vib","/CP044896_VMw.zip/metadata.zip/vendor-index.xml","/CP044896_VMw.zip/metadata.zip/vmware.xml","/CP044896_VMw.zip/metadata.zip/vibs/CP044896--6624025596240225901.xml","/CP044896_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044896_3.15.8.37-7.0.0.15843807.xml"],"md5sum":"70d6ad4a9fd4b8f0849a8a41d4320801","name":"CP044896.zip","release":"2021-01-21T09:32:05","revision":"0","sha1sum":"45ee25a78d8fc742df5082aa0982ca863921dfb4","size":"28MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"0","version":"3.15.8","vib_list":[{"name":"CP044896","version":"3.15.8.37-7.0.0.15843807"}]}],"id":{"product":"a08198f75ae64d5f81f313aee3e10a81","version":"d173272a9cc245e4861876ba2d4b0cd5"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Installation instructions are available in CP044896.txt, which is included in CP044869.zip.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ OCP3 Adapter for HPE</li>\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ Adapter for HPE&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000GWKGVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4256224","datemodified":"2020-12-17T07:16:44","file_list":["cp045519.xml","cpqsetup.exe","HVLAnAaseFG1.rel","payload.json","setup.dll"],"md5sum":"a8c8f53dc41521413bb923a130c10454","name":"cp045519.exe","release":"2020-12-17T07:00:12","revision":"0","sha1sum":"e96116f16e22cbd50e145038c2d0c14fe26d37ab","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"0d61334622ba44aeb0c163514d9f57b9","version":"b5119cc9c731423694fa8dea6b0e59de"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:39:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8917617","datemodified":"2021-02-09T16:11:14","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/12","./usr/lib/.build-id/12/c86c12a657179c1c63d1a4e432a9b0e3d7d0e7","./usr/lib/.build-id/17","./usr/lib/.build-id/17/ba35b00a33cfe13d05b12a161ddf2471bd7972","./usr/lib/.build-id/27","./usr/lib/.build-id/27/fb8222a394f590bfccd38a75dec115da205ffb","./usr/lib/.build-id/35","./usr/lib/.build-id/35/229801f0caf3cf99219845db05035f71fbe3f5","./usr/lib/.build-id/82","./usr/lib/.build-id/82/86ea0da58a69a3ec3d37d1a0a6ee28644ff4a3","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/ef9a88f1cd8954e341406f714c6e8038626616","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/d5abe6ca73c2b476f94c3dc0263e80d02bff74","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"d5b76a0a997f32f5bc5bc8e08fad5211","name":"mft-4.16.0-105.rhel8u3.x86_64.rpm","release":"2021-02-09T15:58:04","revision":"0","sha1sum":"cb1b7d8429a973d913e3456db186e5cd7030a8d9","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"},{"bytes":"19665","datemodified":"2021-02-09T16:06:56","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"f87b4f3a95fc2c337e4d8d55a730b6c7","name":"kmod-kernel-mft-mlnx-4.16.0-1.rhel8u3.x86_64.rpm","release":"2021-02-09T15:58:04","revision":"0","sha1sum":"8bd005d15892e3d617723b4ee3270710b5b7bdbd","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"}],"id":{"product":"549939a4e5cb4543b7385d514127ff29","version":"c26e66b87b8b4e5580b1d31372b7802a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-240.el8.x86_64&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.16.0-1.rhel8u3.x86_64.rpm&nbsp;&nbsp;mft-4.16.0-105.rhel8u3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 3 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8915944","datemodified":"2021-02-09T16:32:18","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"c005ff37f7b304bc51f5448de0d0717f","name":"mft-4.16.0-105.sles12sp5.x86_64.rpm","release":"2021-02-09T16:28:05","revision":"0","sha1sum":"f074db85db922981f854152fd94cfcc6289703dc","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.16"},{"bytes":"18726","datemodified":"2021-02-09T16:36:38","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/mst_pci.ko","./lib/modules/4.12.14-120-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"e7005988e631a662d82fcd14feed1281","name":"kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-02-09T16:28:05","revision":"0","sha1sum":"8cb09420b882c77f5c1366810920b43ffe91be58","size":"18KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.16"}],"id":{"product":"121737c377d94d3aa35bfe198f1f6e1f","version":"5e3c3d9560eb435db75018fb576fd4b1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_120-1.sles12sp5.x86_64.rpm&nbsp; mft-4.16.0-105.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000GFECR Drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB8000GFECRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17151398","datemodified":"2021-01-28T16:24:51","file_list":["/CP045713_BUILD_3.data","/CP045713.vmexe","/CP045713.vmexe64","/CP045713.vmfile","/CP045713_VMw.zip","/CP045713.xml","/payload.json","/CP045713_VMw.zip/index.xml","/CP045713_VMw.zip/vendor-index.xml","/CP045713_VMw.zip/metadata.zip","/CP045713_VMw.zip/vib20/CP045713/HPE_bootbank_CP045713_HPG6.3-7.0.0.15843807.vib","/CP045713_VMw.zip/metadata.zip/vendor-index.xml","/CP045713_VMw.zip/metadata.zip/vmware.xml","/CP045713_VMw.zip/metadata.zip/vibs/CP045713--196837114832340310.xml","/CP045713_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045713_HPG6.3-7.0.0.15843807.xml"],"md5sum":"b7c80459c5908a896c470e486cc49f9c","name":"CP045713.zip","release":"2021-01-28T16:21:05","revision":"0","sha1sum":"377a3345bd7bd6249b709e48be922ec5c826a2d4","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045713","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"4e50152f0d024f97a52057a7a5220f5a","version":"20faa990cd3941e6afea0adbcf728cd2"},"installation":{"command":"CP040516.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:44:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8693904","datemodified":"2020-11-03T03:49:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/CP045750.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/U43_2.20_10_27_2020.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.20_2020_10_27-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045750.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045750.scexe"],"md5sum":"3b4348aecf36d489a2fe69d5547cb60c","name":"firmware-system-u43-2.20_2020_10_27-1.1.x86_64.rpm","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"25658f812ce5d77f6b732fa6b0b1c1f7384d00d3","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"d3e8a053234f49d9a3735931f34c77c7","version":"3ea62106cd964f79b06e0b520f8e5302"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16740121","datemodified":"2021-01-28T16:04:49","file_list":["/CP045698_BUILD_3.data","/CP045698.vmexe","/CP045698.vmexe64","/CP045698.vmfile","/CP045698_VMw.zip","/CP045698.xml","/payload.json","/CP045698_VMw.zip/index.xml","/CP045698_VMw.zip/vendor-index.xml","/CP045698_VMw.zip/metadata.zip","/CP045698_VMw.zip/vib20/CP045698/HPE_bootbank_CP045698_HPD7.3-7.0.0.15843807.vib","/CP045698_VMw.zip/metadata.zip/vendor-index.xml","/CP045698_VMw.zip/metadata.zip/vmware.xml","/CP045698_VMw.zip/metadata.zip/vibs/CP045698--842313390948878896.xml","/CP045698_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045698_HPD7.3-7.0.0.15843807.xml"],"md5sum":"7f5049bbfafc5ae9d8d1bcf403a36a37","name":"CP045698.zip","release":"2021-01-28T16:02:04","revision":"0","sha1sum":"1ebc12be74dedeb1f99165bb45796c1e8077ec05","size":"15MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP045698","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"09b4bcb98476436f9711a4ef6ff6b585","version":"848ac9a3be704676a208fa362299e7b6"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:32:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG2"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG2"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG2"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG2"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG2"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH, MK001920GWUGK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK  Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3123720","datemodified":"2020-12-16T12:40:35","file_list":["cp045570.xml","cpqsetup.exe","M5200SG2.rel","payload.json","setup.dll"],"md5sum":"5fbc5138dbbd7da5777f249efd22419e","name":"cp045570.exe","release":"2020-12-16T12:31:09","revision":"0","sha1sum":"9b67b85b424db4b304cd536058e6ee95f433983c","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"75bc856a96a1425a954558bdb79908f8","version":"306238ef8ca64e59bf1ba7e044349f33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:58:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C220A","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12988890","datemodified":"2021-01-21T17:37:11","file_list":["/CP042526_BUILD_7.data","/CP042526.vmexe","/CP042526.vmexe64","/CP042526.vmfile","/CP042526_VMw.zip","/CP042526.xml","/payload.json","/CP042526_VMw.zip/index.xml","/CP042526_VMw.zip/vendor-index.xml","/CP042526_VMw.zip/metadata.zip","/CP042526_VMw.zip/vib20/CP042526/HPE_bootbank_CP042526_2021.02.01.7-6.5.0.4240417.vib","/CP042526_VMw.zip/metadata.zip/vendor-index.xml","/CP042526_VMw.zip/metadata.zip/vmware.xml","/CP042526_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042526_2021.02.01.7-6.5.0.4240417.xml","/CP042526_VMw.zip/metadata.zip/vibs/CP042526-3067850072122250309.xml"],"md5sum":"e4fc8920ba4c3c14ddfaf38ce0bc9930","name":"CP042526.zip","release":"2021-01-21T17:34:05","revision":"0","sha1sum":"aba83727f6c9f7f865fd8f1052a83f696919bb17","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153","a6b1a447-382a-5a4f-10DF-0720103C8144","a6b1a447-382a-5a4f-10DF-0722103C8144","a6b1a447-382a-5a4f-10DF-0724103C8144","a6b1a447-382a-5a4f-10DF-0720103C220A","a6b1a447-382a-5a4f-10DF-0724103C220A","a6b1a447-382a-5a4f-10DF-0722103C220A"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042526","version":"2021.02.01.7-6.5.0.4240417"}]}],"id":{"product":"192b893f37784f3bb19222ae8b1fcb3a","version":"3bf27299241d443f9c6788ae5c27b415"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.5"},{"lang":"ja","x_late":"HPEファームウェアフラッシュfor VMware vSphere 6.5用Emulexコンバージドネットワークアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:41:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\"><strong>Firmware</strong></p>\n\n<p><strong>Contains:</strong></p>\n\n<p>CNA (XE100 series) firmware 12.0.1280.5</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<p>UEFI:</p>\n\n<ul>\n\t<li>HPE FlexFabric 20Gb 2-port 650FLB Adapter and HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;does not complete&nbsp;to create boot source on 2nd port</li>\n</ul>\n\n<p>Firmware:</p>\n\n<ul>\n\t<li>Light Emiiting Diode(LED) is in&nbsp;invalid state when disable the port under Unified Extensible Firmware Interface (UEFI)</li>\n\t<li>Duplicate Entries found in firmware report under NIC details for few adaptors.</li>\n\t<li>Full adapter name is not displayed for HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;in some Rom Based Setup Utility (RBSU).</li>\n\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD8"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17259948","datemodified":"2021-01-28T08:55:40","file_list":["/CP045674_BUILD_3.data","/CP045674.vmexe","/CP045674.vmexe64","/CP045674.vmfile","/CP045674_VMw.zip","/CP045674.xml","/payload.json","/CP045674_VMw.zip/index.xml","/CP045674_VMw.zip/vendor-index.xml","/CP045674_VMw.zip/metadata.zip","/CP045674_VMw.zip/vib20/CP045674/HPE_bootbank_CP045674_HPD8.3-7.0.0.15843807.vib","/CP045674_VMw.zip/metadata.zip/vendor-index.xml","/CP045674_VMw.zip/metadata.zip/vmware.xml","/CP045674_VMw.zip/metadata.zip/vibs/CP045674-4411667161945052087.xml","/CP045674_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045674_HPD8.3-7.0.0.15843807.xml"],"md5sum":"16f641431a7565679a59b1e03c041d98","name":"CP045674.zip","release":"2021-01-28T08:53:06","revision":"0","sha1sum":"2d16768aaff2c4e805d2befbb120623eefe936bb","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"0","version":"HPD8","vib_list":[{"name":"CP045674","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"6f1e3dc0362445eba42c38fd34e5d638","version":"b1e30f32e2a7409289a8cfad4582fdd4"},"installation":{"command":"CP042542.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:13:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Marvell FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するMarvell FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v8.55.12.&nbsp;This combo image includes: PXE: 2.0.19, Boot Code (MFW): 8.55.22.0, and UEFI: 6.1.8.2.</p>\n"}],"files":[{"bytes":"2218722","datemodified":"2021-01-21T06:59:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/CP044969.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/CP044969.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/nic_fw/ql_ah_mbi_open_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-1.10.8-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044969.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044969.scexe"],"md5sum":"86b1a2f377b027b24c513675f730f150","name":"firmware-nic-is-marvell-flq-1.10.8-1.1.x86_64.rpm","release":"2021-01-21T06:50:08","revision":"0","sha1sum":"1ebe9e9eb79bc044acf1cd127cc63f10797d994f","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"type_of_change":"0","version":"1.10.8"}],"id":{"product":"9ae794893ab74650b932b0d43d0328bd","version":"117b0672d7ef4c5bb0eca02886b299f8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP044969.txt file.The results of the firmware upgrade are saved&nbsp;in CP044969.log at &quot;/var/cpq/&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ja","x_late":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue of inconsistent LED behavior while linking up with different speed.</li>\n\t<li>This product corrects an issue about failing to restore the factory default value by pressing F7.</li>\n\t<li>This product addresses an issue where driver doesn&rsquo;t load upon booting up by correct memory relocation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supported NPAR enabling option.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product contains support PLDM firmware upgrade base improvements.</li>\n\t<li>This product addresses an overheat issue on the network adapters as below,</li>\n</ul>\n\n<p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />\nHPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_MARVELL_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11146340","datemodified":"2021-01-27T22:53:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/CP046691.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/U45_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046691.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046691.scexe"],"md5sum":"4432ae856ed32cd2c961c9c7ab1291c2","name":"firmware-system-u45-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-27T22:45:05","revision":"0","sha1sum":"21d729b43f43a565922c6bd7ad08bb014e2dcb4a","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"1f91b74faf084255b33a9e102dcf221d","version":"029dae74586643ab87759aa367b7ab68"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T22:17:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Added a new BIOS/Platform Configuration (RBSU) option to Advanced PCIe Device Configuration called PCIe Switch MMIO Configuration.  This option addresses a virtualization issue caused by different interpretations of the PCIe specification by disabling PCIE Switch MMIO Configuration.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp;</strong> None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5166880","datemodified":"2021-03-23T10:42:00","file_list":["cp047338.xml","cpqsetup.exe","KPE60X1GHPK3.rel","payload.json","setup.dll"],"md5sum":"2ac12230ae2f2e2eb71a7531c5325fb7","name":"cp047338.exe","release":"2021-03-23T10:34:05","revision":"0","sha1sum":"0e82af003c286b119c81936f5d8b8769169f93f3","size":"4MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"d026cab87ecf46f4a70676c4643d63f0","version":"9a2c87630a4344e8a8e989cf0929b500"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-23T10:29:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes. "},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1024097","datemodified":"2018-03-02T03:37:04","file_list":["/CP035161.vmexe","/CP035161.vmfile","/CP035161.xml","/README.txt"],"md5sum":"cc1f7c8c520ea366c1e9caca8fdf4b28","name":"CP035161.zip","release":"2018-03-02T09:34:04","revision":"0","sha1sum":"e9e3deeea769baa87e07e5a4d2c5748806bdcf27","size":"0MB","target_guids":[],"type_of_change":"0","version":"8.4","vib_list":[]}],"id":{"product":"2c10c37c94934b028d1c460ce9f457fb","version":"c6b29241292145d8af4d872005ebf538"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.&nbsp;&nbsp;<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for&nbsp;6.5 is 6.5.8.<br />\n<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。  <br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>リモートオンライン、コンポーネントはSUMでサポートされますが、まだSPPの一部ではありません:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします：<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware - NVMe Backplane PIC Firmware "},{"lang":"ja","x_late":"VMware 用オンラインフラッシュコンポーネント - NVMeバックプレーンPICファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-28T12:53:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type: square;\">\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<strong>Note:</strong>&nbsp;If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (C).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added ESXi 6.7 OS support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB6000GEQUT and MB8000GEQUU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB6000GEQUTおよびMB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17455387","datemodified":"2021-01-28T12:19:58","file_list":["/CP045662_BUILD_5.data","/CP045662.vmexe","/CP045662.vmexe64","/CP045662.vmfile","/CP045662_VMw.zip","/CP045662.xml","/payload.json","/CP045662_VMw.zip/index.xml","/CP045662_VMw.zip/vendor-index.xml","/CP045662_VMw.zip/metadata.zip","/CP045662_VMw.zip/vib20/CP045662/HPE_bootbank_CP045662_HPGB.5-7.0.0.15843807.vib","/CP045662_VMw.zip/metadata.zip/vendor-index.xml","/CP045662_VMw.zip/metadata.zip/vmware.xml","/CP045662_VMw.zip/metadata.zip/vibs/CP045662--7658289666029863315.xml","/CP045662_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045662_HPGB.5-7.0.0.15843807.xml"],"md5sum":"6e3f5d7e48963782e4870ef270e8fc12","name":"CP045662.zip","release":"2021-01-28T12:17:06","revision":"0","sha1sum":"f7ae59690de7d01b5205b10ed264fbeafdd4fca7","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP045662","version":"HPGB.5-7.0.0.15843807"}]}],"id":{"product":"ef9e3c99746c4ae380ca5d0cac6d2b97","version":"2ad68ad9536546799b2eb7866b8f3fda"},"installation":{"command":"CP040632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"},{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:03:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"8126044","datemodified":"2020-12-12T22:13:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/CP045367.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-5.1/spannsK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045367.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045367.scexe"],"md5sum":"c8667e20be62c4c978e9965194bb91fd","name":"firmware-hdd-b45e49679c-HPK4-5.1.x86_64.rpm","release":"2020-12-12T22:01:05","revision":"0","sha1sum":"7abcbd8fbf4f099508d85d084b43215b09923e9d","size":"7MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ff420d2a518645bca112d4ae29440c26","version":"e8ee583b088a4fc2bdbbb9f9b11e9844"},"installation":{"command":"CP040920.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"Linux用オンラインNVMe SSDフラッシュコンポーネント（x64）- MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:15:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB6000JVYZD and MB4000JVYZC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：MB6000JVYZDおよびMB4000JVYZCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed: </strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3691304","datemodified":"2020-12-16T16:57:31","file_list":["cp045556.xml","cpqsetup.exe","payload.json","setup.dll","SMBPESD4.rel"],"md5sum":"9d74c5b1ca3c02a35399780be4ea7576","name":"cp045556.exe","release":"2020-12-16T16:49:04","revision":"0","sha1sum":"9daac2b5e911848616ff40be4a8237b9e7577f0a","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"29d3ee50608a4989be087dbfc8603ca4","version":"809a3c7991a24748a7fdf353ff041a0f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYZD and MB4000JVYZC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:52:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for Blade QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP1."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP1で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"99628","datemodified":"2020-02-12T18:46:21","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/85","./usr/lib/.build-id/85/c3cfa1e86cfabbf8aae2b9075be2b98b9f29d2","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"fd97603fda31237994a666c33ef170e6","name":"iscsiuio_bl-2.11.5.13-3.sles15sp1.x86_64.rpm","release":"2020-02-12T18:45:06","revision":"0","sha1sum":"a46e773cf9f039fd6a4e42a1cae2dcdd489dc6fc","size":"97KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"48c9c127d8e84c96aa3d591f450ace21","version":"556182e6fc1246258154795ae211f65c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP1"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEPA and MB4000JFEPB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB2000JFEPAおよびMB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5462639","datemodified":"2020-12-13T13:28:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/CP045432.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/SMKRAND5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045432.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045432.scexe"],"md5sum":"6c26282488e18f126102e392a2ac71b5","name":"firmware-hdd-326de7c0f2-HPD5-7.1.x86_64.rpm","release":"2020-12-13T13:16:14","revision":"0","sha1sum":"bcd72e23b524d76ba4bb952508bcaa29cfc50b53","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"cd64600f655f440ba11117463945fc63","version":"5a57dfdd382a47d3875c013ccaed6a28"},"installation":{"command":"CP040291.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1648018","datemodified":"2021-01-22T05:00:52","file_list":["./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/i386/lib/libbrcmemsdm.so","./opt/broadcom/rhel7/i386/lib/libbrcmhbaapi.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"c835ade1ee889ee087a7725d778fe30e","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel7.x86_64.rpm","release":"2021-01-22T04:56:36","revision":"0","sha1sum":"4ba26e0ee217e7f2e927bff9bb2840094d9a00f2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"7821f460e2f3488c95e92c25e76c9d75","version":"0940cb49a3fb403088543376cba34a99"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1264.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: VK003840GWSXL drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK003840GWSXLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16384034","datemodified":"2021-01-28T12:43:58","file_list":["/CP045684_BUILD_3.data","/CP045684.vmexe","/CP045684.vmexe64","/CP045684.vmfile","/CP045684_VMw.zip","/CP045684.xml","/payload.json","/CP045684_VMw.zip/index.xml","/CP045684_VMw.zip/vendor-index.xml","/CP045684_VMw.zip/metadata.zip","/CP045684_VMw.zip/vib20/CP045684/HPE_bootbank_CP045684_HPG2.3-7.0.0.15843807.vib","/CP045684_VMw.zip/metadata.zip/vendor-index.xml","/CP045684_VMw.zip/metadata.zip/vmware.xml","/CP045684_VMw.zip/metadata.zip/vibs/CP045684-4544452167211214899.xml","/CP045684_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045684_HPG2.3-7.0.0.15843807.xml"],"md5sum":"bbf0c926e13dc83bc631106c1dc5afb9","name":"CP045684.zip","release":"2021-01-28T12:41:04","revision":"0","sha1sum":"4e7e7c21b8f3a1b838ebcf05abf72078c52745b4","size":"15MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045684","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"f2d480bbb5d747efac90df2828bbca07","version":"5a2a7a841e5a49b0a721dbfb7f8c830c"},"installation":{"command":"CP040786.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:21:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"4254904","datemodified":"2020-12-17T06:10:42","file_list":["cp045524.xml","cpqsetup.exe","HVLAeAsseFD1.rel","payload.json","setup.dll"],"md5sum":"a18680815837f5a50895fc9a9e25960f","name":"cp045524.exe","release":"2020-12-17T05:58:09","revision":"0","sha1sum":"598f4ad968332019754899b05417225c1d2df803","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"3c5ca1f7884d46278989b90e474b83e1","version":"4f883aa682bb47339ad67b59fd19c789"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:40:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17498252","datemodified":"2021-01-28T11:59:20","file_list":["/CP045657_BUILD_5.data","/CP045657.vmexe","/CP045657.vmexe64","/CP045657.vmfile","/CP045657_VMw.zip","/CP045657.xml","/payload.json","/CP045657_VMw.zip/index.xml","/CP045657_VMw.zip/vendor-index.xml","/CP045657_VMw.zip/metadata.zip","/CP045657_VMw.zip/vib20/CP045657/HPE_bootbank_CP045657_HPGB.5-7.0.0.15843807.vib","/CP045657_VMw.zip/metadata.zip/vendor-index.xml","/CP045657_VMw.zip/metadata.zip/vmware.xml","/CP045657_VMw.zip/metadata.zip/vibs/CP045657-879139954820590893.xml","/CP045657_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045657_HPGB.5-7.0.0.15843807.xml"],"md5sum":"a11a004033dc2dc658fc23148cf6b863","name":"CP045657.zip","release":"2021-01-28T11:56:18","revision":"0","sha1sum":"9f445ef70706111138b8828a171b1191666bbd36","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP045657","version":"HPGB.5-7.0.0.15843807"}]}],"id":{"product":"6a439b96c74c406881767d161dad104f","version":"c89bc23a0932455cb9b4fb596f35184a"},"installation":{"command":"CP039425.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:59:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MK0960GECQK "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MK0960GECQK "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n  Online HDD/SSD Flash Component for Windows  (x64) - MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong><strong>Enhancements/New Features</strong>:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2718424","datemodified":"2020-12-16T16:05:16","file_list":["cp045562.xml","cpqsetup.exe","GSV843G3.rel","payload.json","setup.dll"],"md5sum":"b7d49f88b5f59cd1eaf1cdad22ab1db8","name":"cp045562.exe","release":"2020-12-16T15:57:05","revision":"0","sha1sum":"4f287d8a7d79034232a1929ff26f638cf4c9a571","size":"2MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"d3eb22b830d045a89e85774c90558992","version":"7fd8d315345a4b08bebcef9f59a5f856"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK0960GECQK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:54:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3926832","datemodified":"2020-12-03T18:55:26","file_list":["cp044766.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.352.12-1/boot/","elxflashStandalone-windows-12.8.352.12-1/firmware/","elxflashStandalone-windows-12.8.352.12-1/firmware/A12835212.grp","elxflashStandalone-windows-12.8.352.12-1/win/","elxflashStandalone-windows-12.8.352.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.352.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.352.12-1/win/x64/","elxflashStandalone-windows-12.8.352.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.352.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.352.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.352.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.352.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"0dd7ac2a2375cde596f888cc2a96d99a","name":"cp044766.exe","release":"2020-12-03T18:33:04","revision":"0","sha1sum":"f61314456941beaa84589a3c1ac37a728cd5d04d","size":"3MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"facf75b5c7944efda90a1807afad2c8a","version":"b8065b615fcd4c5a874cce9cb0e00eaa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Microsoft Windows Server 2012R2/2016/2019 x64"},{"lang":"ja","x_late":"Emulex Mezzanineファイバーチャネルホストバスアダプター用HPEファームウェアオンラインフラッシュ - Microsoft Windows Server 2012R2/2016/2019 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>12.60a4</td>\n\t\t\t<td>2.10X6</td>\n\t\t\t<td>12.6.284.0</td>\n\t\t\t<td>12.6.302.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.7</td>\n\t\t\t<td>12.6.271.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-514180897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-560580897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-001080897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-551580897a09","Version":"1.2.0.5435"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Linux Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers."},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のオンラインLinuxファームウェアコンポーネントを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"448495","datemodified":"2020-06-18T15:57:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/CP044605.xml","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/cp042963.compsig","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/cp042963.zip","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5435-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044605.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044605.scexe"],"md5sum":"f87f92e7dd934b6adc720582b937ccf3","name":"firmware-dcpmm-1.2.0.5435-2.1.x86_64.rpm","release":"2020-06-18T15:51:05","revision":"0","sha1sum":"c730c8d7d908e70ade50b497ec4fc532b1fd733a","size":"437KB","target_guids":["805dd01c-eb5a-1e76-8089-514180897a09","805dd01c-eb5a-1e76-8089-560580897a09","805dd01c-eb5a-1e76-8089-001080897a09","805dd01c-eb5a-1e76-8089-551580897a09"],"type_of_change":"1","version":"1.2.0.5435"}],"id":{"product":"005a4115369b4776b7144bbda87ad6ef","version":"ea7a93c6f547464f90e626017eaa05a0"},"installation":{"command":"CP041747.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ol>\n\t<li>Install the firmware rpm using the command: rpm -ivh &lt;rpm_filename&gt;.&nbsp;</li>\n\t<li>This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location. After installation, navigate into this folder.</li>\n\t<li>The CPxxxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<br />\n\t<br />\n\t# <em>./CPxxxxxx.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)<br />\n\t<br />\n\t# <em>./hpsetup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location<br />\n\t&nbsp;</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ol>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ol>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ol>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use&nbsp;Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ol>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory,&nbsp;/SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow HPE Smart Update Manager steps to complete firmware update.</li>\n</ol>\n\n<p><strong>Online:</strong></p>\n\n<ol>\n\t<li>Login as root. (You must be root in order to apply the&nbsp;update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></p>\n\n<ol>\n\t<li>コマンド rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </li>\n\t<li>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。インストール後、このフォルダーに移動します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'firmware-dcpmem-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<br/>\n\t<br/>\n\t# <em>./CPxxxxxx.scexe</em> in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)<br/><br/># <em>./hpsetup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*' location<br/>\n\t </li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ol>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ol>\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id.  これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-dcpmem-*'ロケーションに移動し、./hpsetupを実行してファームウェアをアップデートします。'firmware-dcpmem-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ol>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br/>\n<br />\n<strong>オフライン：</strong></p>\n\n<ol>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n</ol>\n\n<p><strong>オンライン：</strong></p>\n\n<ol>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネント for Linux - HPE Gen10サーバー上のIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-18T06:55:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</p>\n\n<p>This product contains mainly performance improvements.</p>\n\n<p>This product now supports Red Hat Enterprise Linux 8 and SUSE Linux Enterprise Server 12.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"737686","datemodified":"2021-01-22T07:53:52","file_list":["/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip","/cp044736.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vibs/lpfc--8663881662166312599.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922.xml"],"md5sum":"7b8a044ebb5e696256072e906df28683","name":"cp044736.zip","release":"2021-01-22T07:53:06","revision":"0","sha1sum":"b15d618f975874690ef9d739a21b30f047ac0c02","size":"720KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"6b8b85add4d84390b7e5eded3468099d","version":"8563e1ecc11847a3bbb9cd0306aacd9c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.6.182.2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"}]}],"description":[{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"28025","datemodified":"2020-06-15T10:22:44","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/adapter_info_nx","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/adapter_info_nx","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"55fce15fad78b122f7b5dd0ca0fc38f9","name":"fibreutils-4.1-1_sles.x86_64.rpm","release":"2020-06-15T10:20:04","revision":"0","sha1sum":"168e80e5d4faceb64996fc04e5b8c617fef0fbe8","size":"27KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.1-1"}],"id":{"product":"a32bfc6464f84b51997e9a09f493113b","version":"2082a20ae1d34375af170caa6d819bdf"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"338F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c338f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"338E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c338e","type":"pci","ven":"1077"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-26T08:53:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p>\n","latest_fixes_x_late":"<p>Fixed adpater_info code to display correct Vendor name&nbsp;instead of Unknown</p>\n"},{"curr_enhancements_x_late":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>      None.</p>"}],"files":[{"bytes":"3640760","datemodified":"2020-12-17T12:59:24","file_list":["cp045500.xml","cpqsetup.exe","HCFL4CD6.rel","payload.json","setup.dll"],"md5sum":"87c512fb1dedbbee0528dfb1f753af99","name":"cp045500.exe","release":"2020-12-17T12:50:12","revision":"0","sha1sum":"37b7ecad89e56965688883f8e0760bb4975c18f1","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"8160f18bf46a4d4bb912b9b35f631323","version":"1469d2085fc94851823b8d651aa54866"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:32:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6881967","datemodified":"2021-03-08T20:23:42","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/bnx2.ko","./lib/modules/4.12.14-195-default/updates/bnx2fc.ko","./lib/modules/4.12.14-195-default/updates/bnx2i.ko","./lib/modules/4.12.14-195-default/updates/bnx2x.ko","./lib/modules/4.12.14-195-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"65799ab7cfd502b390f63325203e163d","name":"netxtreme2_bl-kmp-default-7.14.76_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:05:05","revision":"0","sha1sum":"ebce301dfaad025847ed2345593ecf7b192daab5","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"7310425","datemodified":"2021-03-08T20:25:40","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"d0c1c6efaf8d24e55d0f363e0d9eb17a","name":"netxtreme2_bl-kmp-default-7.14.76_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:05:05","revision":"0","sha1sum":"777bbd8d65e8f3456f9e439e254fe4c429541748","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"f76235dc1aee44f3804452ef8c8047d0","version":"baf7df28ec8347b5a7487700763c6c94"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers correct an issue where iSCSI target discovery fails to complete when booting from SAN or a local HD.</p>\n\n<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16129972","datemodified":"2021-01-28T18:52:07","file_list":["/CP045710_BUILD_4.data","/CP045710.vmexe","/CP045710.vmexe64","/CP045710.vmfile","/CP045710_VMw.zip","/CP045710.xml","/payload.json","/CP045710_VMw.zip/index.xml","/CP045710_VMw.zip/vendor-index.xml","/CP045710_VMw.zip/metadata.zip","/CP045710_VMw.zip/vib20/CP045710/HPE_bootbank_CP045710_HPG4.4-7.0.0.15843807.vib","/CP045710_VMw.zip/metadata.zip/vendor-index.xml","/CP045710_VMw.zip/metadata.zip/vmware.xml","/CP045710_VMw.zip/metadata.zip/vibs/CP045710-7658182291698300050.xml","/CP045710_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045710_HPG4.4-7.0.0.15843807.xml"],"md5sum":"12421e366af9a4e5fbde30e4cba11adb","name":"CP045710.zip","release":"2021-01-28T18:49:04","revision":"0","sha1sum":"4201f7e66c3289f7e32bf5690ac6a802afba05aa","size":"15MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045710","version":"HPG4.4-7.0.0.15843807"}]}],"id":{"product":"1cadb74f384743de9dfa8d9d6bc9f7b5","version":"3286086eb5b748aab45a24e76f2f7cd2"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:41:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.2.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1527112","datemodified":"2020-12-03T19:33:27","file_list":["cp044799.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"bb3801aa6fc4206e43f183f7c5422f99","name":"cp044799.exe","release":"2020-12-03T19:24:05","revision":"0","sha1sum":"b17bb5698cb785f3fe6add312c3da0dee82b2f6e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.2.20"}],"id":{"product":"b2fc632eddf5428382301f3ae1e37ede","version":"6d705878a3a947d280f46f8f18dd968c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 9.4.1.20</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Memory dumps were not generated during a crash dump in a boot from SAN environment</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.2.20</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6929119","datemodified":"2020-11-04T21:53:37","file_list":["/CP046162.vmexe","/CP046162.vmfile","/CP046162.xml","/README.txt"],"md5sum":"87ebfbac7fb1b6b7d36f0fce2391307c","name":"CP046162.zip","release":"2020-11-05T03:51:06","revision":"0","sha1sum":"cba52e259dd06c2691d1ef6747df20793307cc2a","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"3592f88084a649b687bec6ded2891596","version":"a768a0ab68394b3fbef3a71f84548e43"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML150 Gen9（P95）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T06:16:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD6"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD6"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for Windows Server 2019</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3767336","datemodified":"2020-12-17T12:38:56","file_list":["cp046213.xml","cpqsetup.exe","payload.json","setup.dll","SKESTND6.rel"],"md5sum":"44f13923bb1f6133b0be475d8d3c7901","name":"cp046213.exe","release":"2020-12-17T12:29:10","revision":"0","sha1sum":"87b5d24ef6aa108abc44d075a21c786e6737742b","size":"3MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"3f2f70c223354bc6b59b77123faa8545","version":"13ad04578e4943cd90239bc9b2a83576"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T07:20:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD4"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPK および EH000600JWHPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16070352","datemodified":"2021-01-27T17:12:01","file_list":["/CP045618_BUILD_3.data","/CP045618.vmexe","/CP045618.vmexe64","/CP045618.vmfile","/CP045618_VMw.zip","/CP045618.xml","/payload.json","/CP045618_VMw.zip/index.xml","/CP045618_VMw.zip/vendor-index.xml","/CP045618_VMw.zip/metadata.zip","/CP045618_VMw.zip/vib20/CP045618/HPE_bootbank_CP045618_HPD4.3-7.0.0.15843807.vib","/CP045618_VMw.zip/metadata.zip/vendor-index.xml","/CP045618_VMw.zip/metadata.zip/vmware.xml","/CP045618_VMw.zip/metadata.zip/vibs/CP045618-3769117880372719129.xml","/CP045618_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045618_HPD4.3-7.0.0.15843807.xml"],"md5sum":"d27ea71fe23686c787b3988522bfe0d9","name":"CP045618.zip","release":"2021-01-27T17:09:04","revision":"0","sha1sum":"75cc2944030d334e880070f60c88d6519efbbb47","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045618","version":"HPD4.3-7.0.0.15843807"}]}],"id":{"product":"f7d7f54393d44f66845199e26d4e5900","version":"f4b68e57d74d443b9bab8161fd4bb2b9"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"},{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:21:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO001600KWZQPおよびMO003200KWZQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7545640","datemodified":"2021-01-25T06:21:41","file_list":["cp045987.xml","cpqsetup.exe","GP173500HPK5.rel","payload.json","setup.dll"],"md5sum":"cdb945e3a4b74a963209f4d036f14e38","name":"cp045987.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"224ba04c61921738edd0b217dbca2ab28006b83b","size":"7MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK5"}],"id":{"product":"7f41af98f1f247caa57376b98f09238f","version":"ac0e3422c58d4ba5a50c9968747cbae9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:29:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2016用 HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1007872","datemodified":"2021-01-14T06:58:51","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045020.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"6b1386867494f2a6e5a8536510a2ae76","name":"cp045020.exe","release":"2021-01-14T06:44:11","revision":"0","sha1sum":"ebe016d20f6ff0538baa6b06027699afe5d07bf8","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"30eade866ed942baab65d2fd9ed8adf2","version":"7256f9c1f56a4269bd6a06120f80d1c2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Broadcom NetXtreme-E 驅動程式"},{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Broadcom NetXtreme-E 드라이버"},{"lang":"cn","x_late":"Windows Server 2016版HPE Broadcom NetXtreme-E驱动程序"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which live firmware upgrade fails when run on both interfaces of the adapter simultaneously.</li>\n\t<li>This product corrects a timeout issue which configures network connection.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an Wake-on-LAN (WoL) function unavailable.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE HBA(Host Bus Adapters) H221"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 HPE HBA（ホストバスアダプター）H221"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Linux - HPE HBA(Host Bus Adapter) H221&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (D)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Improved Integration with Smart Update Manager.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3986270","datemodified":"2018-11-07T04:30:39","file_list":["./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/.setup","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/CP038050.xml","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H210i_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H220_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H220i_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H221_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/H222_it.fw","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/firmware.cfg","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/lsiflash","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/mptsas2.rom","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/sas2flash","./usr/lib/i386-linux-gnu/firmware-43d7eff89e-15.10.10.00-3.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP038050.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP038050.scexe"],"md5sum":"03fe69ec5c28de227185004658e19356","name":"firmware-43d7eff89e-15.10.10.00-3.1.i386.rpm","release":"2018-11-07T10:29:03","revision":"0","sha1sum":"d56cf0c3d39d252d2e14bff78244fc0f6b306bda","size":"3MB","target_guids":[],"type_of_change":"0","version":"15.10.10.00"}],"id":{"product":"b708791c2556438caa9e3c26486663c3","version":"a6849ac36d1c4fd49ad6989aa8203192"},"installation":{"command":"CP038050.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/i386-linux-gnu&#39; location</li>\n\t<li>The CP038050.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-43d7eff89e-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./ CP038050.scexe in the &#39;/usr/lib/i386-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li>./setup in the &#39;/usr/lib/i386-linux-gnu/firmware-smartarray-43d7eff89e-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/i386-linux-gnu/hp-firmware-smartarray-43d7eff89e-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;hp-firmware-smartarray-43d7eff89e-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Host Bus Adapters H221"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPEホストバスアダプターH221"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-02T08:38:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the appropriate FW version for the Host Bus Adapter (HBA) Stockade (H2xx) driver will not install when using the Service Pack ProLiant (SPP)</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"00441590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00461590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00411590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00431590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00421590","sw_key_expectedpath":"firmware:sd:hba"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEXXV Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GEXXVドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n     </strong> None</p>"}],"files":[{"bytes":"3382912","datemodified":"2020-12-16T13:55:06","file_list":["cp045551.xml","cpqsetup.exe","payload.json","setup.dll","TTMRETG2.REL"],"md5sum":"aafc36910762955a797a59f1964ca450","name":"cp045551.exe","release":"2020-12-16T13:46:05","revision":"0","sha1sum":"17c9fb436b729c0d4b1942b7ef9e950a9f364b3a","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"835ec029c284401691cf43baf128212e","version":"eb0d3436f001466ebb9060a03e3f4b00"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:50:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"Smart Storage Administrator Diagnostic Utility CLI 是適用於 Smart Array 控制器及任何受支援裝置之基於命令列的磁碟組態程式，包括為受支援的磁碟機提供 SmartSSD 磨損測量計資訊。"},{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"lang":"ko","x_late":"스마트 스토리지 관리자 진단 유틸리티 CLI는 스마트 어레이 컨트롤러 및 지원되는 장치에 대한 명령줄 기반의 디스크 구성 프로그램이며 지원되는 드라이브에 대한 SmartSSD Wear Gauge 정보도 제공합니다."},{"lang":"cn","x_late":"Smart Storage Administrator Diagnostic Utility CLI 是一款面向智能阵列控制器和所有支持设备的基于命令行的磁盘配置程序，包括为支持的驱动器提供 SmartSSD Wear Gauge 信息。"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされたドライブのSmartSSD Wear Gauge情報の提供を含む、Smartアレイコントローラーおよびサポートされたデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4226421","datemodified":"2021-02-16T11:15:53","file_list":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"md5sum":"f6268fa734e53431ebe274998a5999ef","name":"ssaducli-5.10-44.0.x86_64.rpm","release":"2021-02-16T11:10:07","revision":"0","sha1sum":"f429dbca04b7c48f35ad3c55f7bbc2b5eac25bce","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"type_of_change":"0","version":"5.10.44.0"}],"id":{"product":"7a0e2103ab3d449ea173c873ce94c871","version":"f86788fdfc8b43e6805bf3232834c3b2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Blade Emulex(BRCM) Mezzanine Converged Network Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1148403","datemodified":"2020-07-10T11:06:50","file_list":["/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip","/cp042232.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/brcmfcoe-12.0.1278.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/doc/README.txt","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/doc/release_note_brcmfcoe_12.0.1278.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/vendor-index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/vib20/brcmfcoe/EMU_bootbank_brcmfcoe_12.0.1278.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vibs/brcmfcoe--8968480398887381165.xml"],"md5sum":"305a613fb115bc62d720a5eef01ddba2","name":"cp042232.zip","release":"2020-07-10T11:06:04","revision":"0","sha1sum":"e7370b85a4dfdd9d12d5f672756c9f7b9c343b09","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2e31a109"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmfcoe","version":"12.0.1278.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"00635454b21f4153bb8707b2c8200e57","version":"79c35b5ded0e45f2b4e41b15b4df5393"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex(BRCM) Mezzanine Fibre Channel over Ethernet driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:13:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to Driver version 12.0.1278.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"brcmfcoe:12.0.1278.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27975425","datemodified":"2021-02-03T06:41:51","file_list":["/CP045193.vmexe","/CP045193.vmfile","/CP045193_VMw.zip","/CP045193.xml","/payload.json","/CP045193_VMw.zip/index.xml","/CP045193_VMw.zip/vendor-index.xml","/CP045193_VMw.zip/metadata.zip","/CP045193_VMw.zip/vib20/CP045193/HPE_bootbank_CP045193_1.0.1-6.7.0.7535516.vib","/CP045193_VMw.zip/metadata.zip/vendor-index.xml","/CP045193_VMw.zip/metadata.zip/vmware.xml","/CP045193_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045193_1.0.1-6.7.0.7535516.xml","/CP045193_VMw.zip/metadata.zip/vibs/CP045193--8009697915264003070.xml"],"md5sum":"bb9e9e26dea439f9be2662f56fa7a594","name":"CP045193.zip","release":"2021-02-03T06:48:05","revision":"0","sha1sum":"aee6014af3217cfa12945cd186e0f47798720caa","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.5","vib_list":[{"name":"CP045193","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"8f7bfcc1686841199a7eebcfc658f164","version":"502ccc8e30da4e79a43e0e0c4dd2fb4c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox Ethernet only adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>cq_overrun counter: This counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.29.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for following features:</p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>ixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>&nbsp;An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>The&nbsp;eth_wqe_too_small counter to count&nbsp;ODP page used to fail.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx4 is the low level driver implementation for the ConnectX®-3 and ConnectX®-3 Pro adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"818630","datemodified":"2021-01-29T12:22:58","file_list":["/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip","/cp046345.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/doc/README.txt","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/doc/release_note_nmlx4-rdma_3.19.70.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/doc/release_note_nmlx4-en_3.19.70.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/vendor-index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.19.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.19.70.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip/vmware.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip/vibs/nmlx4-en--1135219844456576062.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip/vibs/nmlx4-rdma--132306099509880181.xml","/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-16834350.zip/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922-offline_bundle-16834350.zip/metadata.zip/bulletins/Mellanox-nmlx4_3.19.70.1-1OEM.670.0.0.8169922.xml"],"md5sum":"948def5a37f53a674ab78ce84c83b5c0","name":"cp046345.zip","release":"2021-01-29T12:20:05","revision":"0","sha1sum":"e805c4b66b60070613089ac9a04311ede82aee7a","size":"799KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec9f71a861"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-en","version":"3.19.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-rdma","version":"3.19.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"7b0103ddf3b44215b7f92f0c298c391f","version":"d1e1b5187a8249d182dde1fea87ae71c"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx4_en Driver Component for VMware 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-24T14:24:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 3.19.70.1:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx4-en:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Mellanox-nmlx4:3.19.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6880765","datemodified":"2020-11-04T22:19:37","file_list":["/CP046139.vmexe","/CP046139.vmfile","/CP046139.xml","/README.txt"],"md5sum":"662332d3a4c8df0f481a1747acb5eaa9","name":"CP046139.zip","release":"2020-11-05T04:17:06","revision":"0","sha1sum":"65d81c74e66c0dc3da2592ca40759ab461dfb34f","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"7615104752d44337b92336bf27de44e5","version":"37fcd43484ab45d19000cd43bb21670d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML110 Gen9（P99）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-23T09:15:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp043545.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp043596.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.2.0"}]},"DirectoryScan":false,"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバーをアップデートします "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4305688","datemodified":"2020-03-25T20:11:58","file_list":["cp043545.compsig","cp043545.zip","cp043588.xml","cp043596.compsig","cp043596.zip","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"c13277ad70d1be4e65d1eb3ec72f0730","name":"cp043588.exe","release":"2020-04-01T00:00:00","revision":"1","sha1sum":"c3d0cf8d1ab94e883a61fe2d368e93ecc33827b0","size":"4MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.2.0"}],"id":{"product":"effc199f67764de3b570f964be1aa0ce","version":"8fbafa0a10a047d394d2bc8943d12be5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-07-12T03:46:49","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None  <P><B>Firmware Dependencies:</B></P>None  <P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where Processor or Memory temperature reporting may not be collected properly by the platform and the system fans may be running faster than expected. This issue has been seen occasionally after a server reboot and is typically corrected with a subsequent server reboot. <P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<P><B>Important Notes:</B></P>None  <P><B>Firmware Dependencies:</B></P>None  <P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where Processor or Memory temperature reporting may not be collected properly by the platform and the system fans may be running faster than expected. This issue has been seen occasionally after a server reboot and is typically corrected with a subsequent server reboot. <P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"427029","datemodified":"2021-01-28T10:24:39","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"b74de0d5594dbbad52dc777367be188b","name":"brcmfcoe-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-28T10:20:08","revision":"0","sha1sum":"23682883a85d57cd7ab3e96fa3d0d4d1baf02184","size":"417KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"497dff17dd524ba3a936f4d2ccd99da8","version":"2bc5099c415c4f15bd7821c42484224c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 service pack 5 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:37:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1259.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG2"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG2"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG2"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17795473","datemodified":"2021-01-28T20:34:55","file_list":["/CP046506_BUILD_1.data","/CP046506.vmexe","/CP046506.vmexe64","/CP046506.vmfile","/CP046506_VMw.zip","/CP046506.xml","/payload.json","/CP046506_VMw.zip/index.xml","/CP046506_VMw.zip/vendor-index.xml","/CP046506_VMw.zip/metadata.zip","/CP046506_VMw.zip/vib20/CP046506/HPE_bootbank_CP046506_HPG2.1-7.0.0.15843807.vib","/CP046506_VMw.zip/metadata.zip/vendor-index.xml","/CP046506_VMw.zip/metadata.zip/vmware.xml","/CP046506_VMw.zip/metadata.zip/vibs/CP046506-1095458105975755829.xml","/CP046506_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046506_HPG2.1-7.0.0.15843807.xml"],"md5sum":"5c36a63dd7bb73a6201355e1e9d53fc2","name":"CP046506.zip","release":"2021-01-28T20:32:05","revision":"0","sha1sum":"3464c6dd331d2129483a37baaa8a87f85bcfb773","size":"16MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"0","version":"HPG2","vib_list":[{"name":"CP046506","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"a4fb8dc02faf478a85519ccf77530c6a","version":"dd9de34e9fc74b60b7f9f8b3eb159b60"},"installation":{"command":"CP041496.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-05T08:05:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB006000GWKGR drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB006000GWKGRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18659629","datemodified":"2021-01-28T06:41:40","file_list":["/CP045635_BUILD_8.data","/CP045635.vmexe","/CP045635.vmexe64","/CP045635.vmfile","/CP045635_VMw.zip","/CP045635.xml","/payload.json","/CP045635_VMw.zip/index.xml","/CP045635_VMw.zip/vendor-index.xml","/CP045635_VMw.zip/metadata.zip","/CP045635_VMw.zip/vib20/CP045635/HPE_bootbank_CP045635_HPG1.8-7.0.0.15843807.vib","/CP045635_VMw.zip/metadata.zip/vendor-index.xml","/CP045635_VMw.zip/metadata.zip/vmware.xml","/CP045635_VMw.zip/metadata.zip/vibs/CP045635-3904588657540954791.xml","/CP045635_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045635_HPG1.8-7.0.0.15843807.xml"],"md5sum":"9b62a84e161061b0b24494ad6b4e5c0c","name":"CP045635.zip","release":"2021-01-28T06:38:04","revision":"0","sha1sum":"a81dda71f9e10399be9286287c8483be1f86b332","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045635","version":"HPG1.8-7.0.0.15843807"}]}],"id":{"product":"cfe4c5a213fb4be397a8b588efd29cc1","version":"84707e9a8dee4410a2df2a215d25d354"},"installation":{"command":"CP041520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWKGR ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:38:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.80"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.80"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.80"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"28903724","datemodified":"2021-01-21T07:46:54","file_list":["/CP044814_BUILD_39.data","/CP044814.vmexe","/CP044814.vmexe64","/CP044814.vmfile","/CP044814_VMw.zip","/CP044814.xml","/payload.json","/CP044814_VMw.zip/index.xml","/CP044814_VMw.zip/vendor-index.xml","/CP044814_VMw.zip/metadata.zip","/CP044814_VMw.zip/vib20/CP044814/HPE_bootbank_CP044814_1.28.6.39-7.0.0.15843807.vib","/CP044814_VMw.zip/metadata.zip/vendor-index.xml","/CP044814_VMw.zip/metadata.zip/vmware.xml","/CP044814_VMw.zip/metadata.zip/vibs/CP044814--759850172800902617.xml","/CP044814_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044814_1.28.6.39-7.0.0.15843807.xml"],"md5sum":"ea2d11e2b3273a1e157eae4d7ca117f2","name":"CP044814.zip","release":"2021-01-21T07:44:11","revision":"0","sha1sum":"558f55b58445245bcb39b13c8a6dd330426c4835","size":"27MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"0","version":"1.28.6","vib_list":[{"name":"CP044814","version":"1.28.6.39-7.0.0.15843807"}]}],"id":{"product":"03d55b6f216746b88ddef311b0a8c1f9","version":"6f64d75d2ca14f9290180170b3144842"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE QLogic NX2 上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE QLogic NX2在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product improves the functionality for the MBI firmware update.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects the display problem of the adapter name under RBSU.</li>\n\t<li>This products corrects some issues about the thermal reporting and temperature threadshold control of the adapter.</li>\n\t<li>This product addresses an error when the MBI firmware update is executed in the secure boot mode.</li>\n\t<li>This product addresses an issue where unexpected UMCE(Uncorrectable Machine Check Exception) appeared when powering on the system with NPAR(Network Partitioning) enabled.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue that platform would be randomly waked up by WOL packet.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"74582","datemodified":"2020-10-01T11:42:26","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpsa","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpsa/hpsa.ko","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"40ee86d5a676269ac5006883e5fbd246","name":"kmod-hpsa-3.4.20-202.rhel7u8.x86_64.rpm","release":"2020-10-01T11:35:06","revision":"0","sha1sum":"f19c5d5b7c0861072718576372fda6690353207b","size":"72KB","target_guids":[],"type_of_change":"1","version":"3.4.20-202"},{"bytes":"74580","datemodified":"2020-10-01T11:44:31","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpsa","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpsa/hpsa.ko","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"07f6814ff52338ca6178891c0cb87760","name":"kmod-hpsa-3.4.20-202.rhel7u9.x86_64.rpm","release":"2020-10-01T11:35:06","revision":"0","sha1sum":"7f6ba8dba05cda63624bf758c1b78155488d694d","size":"72KB","target_guids":[],"type_of_change":"1","version":"3.4.20-202"}],"id":{"product":"438f6bb803b440feb816d6663cff3bca","version":"96d984a607d74a19a2c9198c5de16fde"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p> </p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T15:42:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 8</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045275.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2147419","datemodified":"2020-11-05T06:31:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/CP045277.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/cp045275.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/cp045275.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.208-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045277.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045277.scexe"],"md5sum":"4adba1bff3a4e4601dc3102faacbc12c","name":"firmware-microservergen10plussps-05.01.04.208-1.1.x86_64.rpm","release":"2020-11-05T06:24:08","revision":"0","sha1sum":"e6a61466d6f0605a5544d6790ff475fbf57b822c","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"667c48761fdd439199126de11a3666a8","version":"2e2783b7dd934f80b12f1232639b4028"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T03:13:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1130216","datemodified":"2020-12-02T17:44:47","file_list":["cp045175.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn64x64.cat","ixn64x64.din","ixn64x64.inf","ixn64x64.sys","ixnmsg.dll","NicCo36.dll","nicco5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"01bbc49970514416f3c1c53928ff20c9","name":"cp045175.exe","release":"2020-12-02T17:31:05","revision":"0","sha1sum":"2d9b5e0da0733e778e7b3b56dc541cf0466a4adc","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecee44051c"],"type_of_change":"0","version":"3.14.214.0"}],"id":{"product":"08fe2c1296bd42698b5f247147246702","version":"7fb61d29633941e1a5bd455dd24b8141"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, ixtmsg.dll, nicco5.dll, and nicinitx.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"4443192","datemodified":"2021-02-16T06:01:30","file_list":["/cp044433.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/index.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vendor-index.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/ilo_650.10.7.0.4-1OEM.650.0.0.4240417.vib","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/sutesxcli-6.5.0.2.8.0.0-12.vib","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/cru_650.6.5.9.8-1.4240417.vib","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/sut-6.5.0.2.8.0.0-20.vib","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vmware.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vendor-index.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/bulletins/sut-esxi6.5-offline-bundle-2.8.0.0-22.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vibs/cru--6127564140410200699.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vibs/sut--2027295640499792465.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vibs/ilo--424181866709235809.xml","/sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/metadata-sut-esxi6.5-offline-bundle-2.8.0.0-22.zip/vibs/sutesxcli--5322727997609154156.xml"],"md5sum":"28524ee98017c38317ba8d2ce38468f9","name":"cp044433.zip","release":"2021-02-16T05:59:05","revision":"0","sha1sum":"08a92e353024623dce1d887af72731d721112708","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecf680a7e2","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"type_of_change":"1","version":"2021.04.00","vib_list":[{"name":"ilo","version":"650.10.7.0.4-1OEM.650.0.0.4240417"},{"name":"sutesxcli","version":"6.5.0.2.8.0.0-12"},{"name":"cru","version":"650.6.5.9.8-1.4240417"},{"name":"sut","version":"6.5.0.2.8.0.0-20"}]}],"id":{"product":"35aedb12078f4cf798d76b05b4d2ddf4","version":"39d8b7fed6af4be9938e37f96ea4f69d"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.5 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v &lt;path&gt;&lt;filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T13:51:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ilo:650.10.7.0.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"sutesxcli:6.5.0.2.8.0.0-12","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:650.6.5.9.8-1.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"sut:6.5.0.2.8.0.0-20","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000GWKGVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6084981","datemodified":"2020-12-13T09:25:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/CP045409.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045409.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045409.scexe"],"md5sum":"145df4841238bf8e1a10e122b59026fd","name":"firmware-hdd-ca21e169e2-HPG1-4.1.x86_64.rpm","release":"2020-12-13T09:10:08","revision":"0","sha1sum":"3c50c088087d286237fc7a569d7218cce7eeb838","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"02a1f5d0f0e244c0b4c2ace636d0f60b","version":"5d58c74bb54a4c4c9d120e89541bfede"},"installation":{"command":"CP041494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"7709014","datemodified":"2021-01-24T09:36:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/CP044873.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw/fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw/fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw/fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044873.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044873.scexe"],"md5sum":"7946896c961e2c6b3b24b4043e768745","name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.6-1.1.x86_64.rpm","release":"2021-01-24T09:35:05","revision":"0","sha1sum":"882830f37ab37091e604a4c4bff5a88939a6d04e","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.6"}],"id":{"product":"dcf87aae93de4d649fef4547bffe751a","version":"5844766b4e254c54915f507af5f883d1"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T11:59:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.27.6008:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when&nbsp;connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>ConnectX-6: 20.27.2008*<br />\n\t\t*Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link&nbsp;speeds.</li>\n\t</ul>\n\t</li>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>Enabled KP4RS FEC on Active Fiber cable up to 30m.</li>\n\t\t<li>FDR protocol.</li>\n\t\t<li>Enabled updating End-to-End (E2E) credit packets instantly.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>There are no new fixes in firmware version 20.27.6008.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.29.1016:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n</ol>\n\n<ol start=\"7\">\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n\n<ul>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"5587432","datemodified":"2019-08-07T16:11:58","file_list":["SignedImageInstaller64.dll","U26_2.66_07_19_2019.signed.flash","cp040771.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"d913b1a150c39dcfe5a977dbe7ed0cd3","name":"cp040771.exe","release":"2019-08-07T15:56:02","revision":"0","sha1sum":"21fc8d9029a886068ec059802f068ab81892dea1","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019"}],"id":{"product":"dd9af2922ef944c1aae83a2243605be9","version":"a94d8cbb2ab44854b1ac6b49efda50cb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T22:56:03","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"cn","x_late":"驱动程序 - 视频"},{"lang":"ja","x_late":"ドライバ - ビデオ"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eHビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"1603248","datemodified":"2019-07-19T14:20:45","file_list":["cp038692.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"md5sum":"db41528c82a1cfa1b876de074a7194d2","name":"cp038692.exe","release":"2019-07-19T14:19:04","revision":"0","sha1sum":"6b9d4614f8add7fe575dc782f1e6286d08218c0d","size":"1MB","target_guids":[],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"c64a84fd2c1c48b694ff9c49365c2913","version":"de2c0f0e28124d849c6fa5c0acf33c6f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Matrox G200eH Video Controller Driver for Windows Server 2016 and Server 2019"},{"lang":"ja","x_late":"Windows Server 2016および2019用Matrox G200eHビデオコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0533","subdev":"330E","subven":"103C","target_guid":"","type":"pci","ven":"102B"},{"dev":"0533","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix for random screen corruption when changing resolution that could occur with driver versions 9.15.1.184 and 9.15.1.218.</li>\n\t<li>Fix for a display freeze that could occur when running the Windows Display Diagnostics tool (dispdiag.exe).</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 2.0.57.0</li>\n\t<li>qfle3, version 1.4.12.0</li>\n\t<li>qfle3f, version 2.1.14.2</li>\n\t<li>qfle3i, version 2.1.5.0</li>\n</ul>\n"}],"files":[{"bytes":"1493323","datemodified":"2021-01-13T14:28:22","file_list":["/cp045166.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.57.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.5.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.12.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.14.2-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3f--3196541751359997041.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qcnic--8985520576553058483.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3--3377191137913857898.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/vibs/qfle3i--3210215708116908819.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807_17340313.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.135.2-1OEM.700.1.0.15843807.xml"],"md5sum":"5b1d980f99e3910a796d40d27f989c8f","name":"cp045166.zip","release":"2021-01-13T14:27:04","revision":"0","sha1sum":"5a4695814de6463e61d1be6337661464c651c164","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"0","version":"2021.04.19","vib_list":[{"name":"qcnic","version":"2.0.57.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.5.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.12.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.14.2-1OEM.700.1.0.15843807"}]}],"id":{"product":"d2fcdefd57524f44b8d7ad99311fad8f","version":"55da9a4a6bc6480c91a9c6a1e1f2508c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.135.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qfle3:1.4.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:2.1.14.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:2.1.5.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:2.0.57.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR416i-a","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-a_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7490140","datemodified":"2021-02-25T05:49:23","file_list":["HPE_MR416i-a_Gen10P_52.16.3-3913.ilo","HPE_MR416i-a_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"5d984c252c5972ccc8053e797ea8ba2f","name":"HPE_MR416i-a_Gen10P_52.16.3-3913.fwpkg","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"221e4c5ed43119f41fedb98c1e5076a6d302a329","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032a"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"c9a4232d8cb349049f544bcc6d02e97f","version":"acb0c12a65bf4eaeb205f29d44602465"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a Gen10 Plus Tri Mode Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T07:18:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"032A1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication."},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"714207","datemodified":"2021-01-28T19:34:00","file_list":["/cp045897.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/index.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/vendor-index.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/vib20/bootcfg/HPE_bootbank_bootcfg_700.10.7.0.3-7.0.0.15525992.vib","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/vib20/hponcfg/HPE_bootbank_hponcfg_700.10.7.0.3-7.0.0.15525992.vib","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/vib20/conrep/HPE_bootbank_conrep_700.10.7.0.8-7.0.0.15525992.vib","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/vib20/testevent/HPE_bootbank_testevent_700.10.7.0.3-7.0.0.15525992.vib","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vendor-index.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vmware.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vibs/bootcfg--5156915718042986920.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vibs/hponcfg--2994263696447055671.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vibs/conrep-3703151478679383947.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/vibs/testevent--8153905253694166828.xml","/HPE-Utility-Component_7.0.0.10.7.0-8_17004542.zip/metadata.zip/bulletins/HPE-Utility-Component_7.0.0.10.7.0-8.xml"],"md5sum":"cd293d28a89d61d14131c64b22a4c461","name":"cp045897.zip","release":"2021-01-28T19:33:05","revision":"0","sha1sum":"4fb6c529a15fccea8a786e803e0fe6a144e2cd30","size":"697KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9eca8969e05","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"bootcfg","version":"700.10.7.0.3-7.0.0.15525992"},{"name":"hponcfg","version":"700.10.7.0.3-7.0.0.15525992"},{"name":"conrep","version":"700.10.7.0.8-7.0.0.15525992"},{"name":"testevent","version":"700.10.7.0.3-7.0.0.15525992"}]}],"id":{"product":"60d50a2d8e934d7ba3009af9a701d8ce","version":"9ca2bd8dad8e46778dff651f0cc246f7"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>HP Smart Update Managerの手順に従って、アップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 7.0"},{"lang":"ja","x_late":"HPEユーティリティバンドルSmartコンポーネント for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T03:11:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports VMware ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Includes an updated the Smart Storage Administrator CLI&nbsp;(SSACLI).</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"conrep:700.10.7.0.8-7.0.0.15525992","sw_key_expectedpath":"software:vmware:zip"},{"name":"bootcfg:700.10.7.0.3-7.0.0.15525992","sw_key_expectedpath":"software:vmware:zip"},{"name":"hponcfg:700.10.7.0.3-7.0.0.15525992","sw_key_expectedpath":"software:vmware:zip"},{"name":"HPE-Utility-Component:7.0.0.10.7.0-8","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"testevent:700.10.7.0.3-7.0.0.15525992","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB8000GFECR Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB8000GFECRドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>     HPG5<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3519760","datemodified":"2020-12-16T16:27:53","file_list":["cp045557.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPTG6.rel"],"md5sum":"25d9988b6cb97ca3ea5f78e694ad7782","name":"cp045557.exe","release":"2020-12-16T16:21:09","revision":"0","sha1sum":"a51b9e9d4e7b2d6e2ba2736b226157be92551f48","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"82d1b2ac21094989a9b2118ea6829df2","version":"6346a49b6d6d47d5b92b9abdf3c77c58"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:52:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD3"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB002000JWFVN and MB004000JWFVP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB002000JWFVNおよびMB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3022192","datemodified":"2020-12-17T07:38:57","file_list":["cp045518.xml","cpqsetup.exe","payload.json","setup.dll","TATCATRsnSD3.REL"],"md5sum":"430bffb7ec6c135c76c78b314fa27998","name":"cp045518.exe","release":"2020-12-17T07:27:09","revision":"0","sha1sum":"bb077be3b0eb9d6f58905c15fafb14142ddb01f0","size":"2MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"2b0745f5d1b9423aa88e57ad4cdfbe00","version":"8a8fad376d14438d9b68b11b3033cfa5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:38:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。また、コマンドラインユーティリティのコレクションを提供します: ProLiantブート構成ユーティリティ（hpbootcfg）、ProLiant管理コマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（blue）ライトユーティリティ（hpuid）。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"369888","datemodified":"2019-12-03T23:57:09","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./usr/lib/.build-id","./usr/lib/.build-id/43","./usr/lib/.build-id/43/debb643029b9a8b7c235f1998e25adcc4b20fd","./usr/lib/.build-id/4e","./usr/lib/.build-id/4e/f3be7a4bacc0ad077d71d19130c6a5880dd414","./usr/lib/.build-id/53","./usr/lib/.build-id/53/bc849684981f58e695f285c01b176cc7ecdc07","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/5efed6a73e49fe5cd1a9e0dd2bca74e9592e97","./usr/lib/.build-id/5f","./usr/lib/.build-id/5f/df01f585f47449f52a90ff40bc142342e570d6","./usr/lib/.build-id/73","./usr/lib/.build-id/73/2a4bb981cc85487b3645f7d58b527d49f3918e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/2fa7dbc3bd1f78886ddd8e8b4812294a98a7c1","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/8834612519f21776171fbdd14e3f05460ceb91","./usr/lib/.build-id/b4/ec4900e48c7159081cf05a73354244cba67e01","./usr/lib/.build-id/bd","./usr/lib/.build-id/bd/b082da314c1a782f05710b9dee71d5045c0a8d","./usr/lib/.build-id/c7","./usr/lib/.build-id/c7/6973f9c1a8a005b995665d3ec94bc06f5fe35d","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"6e88c43decdb5b79934bd02816b44199","name":"hp-health-10.92-5.5.rhel8.x86_64.rpm","release":"2019-12-04T05:50:10","revision":"0","sha1sum":"eb764cc437ee1363d2bf0a6eb12b49508eeeb3ec","size":"361KB","target_guids":[],"type_of_change":"0","version":"10.9.2"}],"id":{"product":"bd87491089a64d5ebd7c9035cfb17538","version":"571589cf4c44486e96a3a87cb54fae04"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for Red Hat Enterprise Linux 8 Server"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-21T13:58:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial support for Red Hat Enterprise Linux 8 Server</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11296843","datemodified":"2021-01-28T12:03:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/CP046640.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/U39_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046640.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046640.scexe"],"md5sum":"387835a85705e615695d520f9b124a75","name":"firmware-system-u39-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T11:56:22","revision":"0","sha1sum":"775041a864f54a6b2400746aeac6ecb6167131c2","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"25afa565c5cd4e359629eee44baf7e64","version":"3ef8f32dd69646faae9db1d772be38be"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5241555","datemodified":"2020-12-13T15:51:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/CP045467.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/G1633HD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045467.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045467.scexe"],"md5sum":"0d26a21925fb6b3957cb53ae05c54dc3","name":"firmware-hdd-4c048aaeb0-HPD8-3.1.x86_64.rpm","release":"2020-12-13T15:40:08","revision":"0","sha1sum":"56b77580588460a269773e1226e174fe6d83e4a6","size":"4MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"3207ab7da97d4b129737d7c53c2ebb76","version":"2e8ea97a00bd4ee8b429f9ee9929c349"},"installation":{"command":"CP042624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"0.37"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"0.37"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 4200&nbsp;Gen10+ Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Initial Release</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5431125","datemodified":"2021-01-26T16:51:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/CP044966.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/Eaglescanyon-Release-0.37.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.37-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044966.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044966.scexe"],"md5sum":"ae8fabbf583326bc0a711c85b865b0a2","name":"firmware-smartarray-f36d4ef431-0.37-1.1.x86_64.rpm","release":"2021-01-26T16:40:04","revision":"0","sha1sum":"1644a8b054042290fcfcd887aec0750eac99c703","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"0.37"}],"id":{"product":"e528a2af212b4bb09bfd3cb54b985653","version":"c2a8b10573d94e60b40263da5437619a"},"installation":{"command":"CP044966.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044966.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP044966.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T16:05:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"607544","datemodified":"2021-03-10T07:51:35","file_list":["cp047086.xml","cpqsetup.exe","Drivers/","Drivers/IceLakeX/","Drivers/IceLakeX/IceLakeX.cat","Drivers/IceLakeX/IceLakeXSystem.inf","Drivers/IceLakeX/IceLakeXSystemNorthpeak.inf","Drivers/Lewisburg/","Drivers/Lewisburg/lewisburg.cat","Drivers/Lewisburg/LewisburgSystem.inf","Drivers/Server_Common.cat","Drivers/Server_CommonSystem.inf","Drivers/Skylake-E/","Drivers/Skylake-E/Skylake-E.cat","Drivers/Skylake-E/Skylake-ESystem.inf","installer.dll"],"md5sum":"3a96204fbe3df305d0fed4f7b736bbeb","name":"cp047086.exe","release":"2021-03-10T07:50:07","revision":"0","sha1sum":"be4e6b37c94bd91504fa15e8e6f884f42af37af5","size":"593KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"1","version":"10.1.18661.8255"}],"id":{"product":"957b79699cf847b3bc804b96d1108938","version":"5a3d510de27c488f9c61fd2eb26770ef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-04-10T07:01:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Removed device &quot;VMD Registers &ndash; 28C0&quot;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\win-nullinf"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2012 R2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1593376","datemodified":"2019-10-24T22:11:16","file_list":["bepnic.dll","bepnic.rtf","cp039927.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd64.cat","ocnd64.inf","ocnd64.sys"],"md5sum":"09c216b31290c28cce3c0fa4f66c57ce","name":"cp039927.exe","release":"2019-10-24T19:55:03","revision":"0","sha1sum":"e9aa9cc9aaa31d862c8b016319f9eed05896ce25","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec173970a5"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"09f59b2aef5e4eee80432b69a5878137","version":"d93cd897307649f39c8b95f8a1a80dd5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-364875f2e83b","Version":"4H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-324808558bd9","Version":"4H3Q"},{"DeviceName":"MZPLJ6T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448edb4b867","Version":"4H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version is now available from the following OS-specific URLs: VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2 Linux: EPK74H3Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; 4H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li style=\"text-align:left\">SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"25198870","datemodified":"2021-02-11T16:28:49","file_list":["/CP046696_BUILD_4.data","/CP046696.vmexe","/CP046696.vmexe64","/CP046696.vmfile","/CP046696_VMw.zip","/CP046696.xml","/payload.json","/CP046696_VMw.zip/index.xml","/CP046696_VMw.zip/vendor-index.xml","/CP046696_VMw.zip/metadata.zip","/CP046696_VMw.zip/vib20/CP046696/HPE_bootbank_CP046696_4H3Q.4-7.0.0.15843807.vib","/CP046696_VMw.zip/metadata.zip/vendor-index.xml","/CP046696_VMw.zip/metadata.zip/vmware.xml","/CP046696_VMw.zip/metadata.zip/vibs/CP046696-7744991206924730151.xml","/CP046696_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046696_4H3Q.4-7.0.0.15843807.xml"],"md5sum":"86c3212e6fc5c51f18bc6277bd27acf5","name":"CP046696.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"dbd0f38e0615023384489ddf5026268363e788a6","size":"24MB","target_guids":["4d2340a5-505a-4a4c-3154-364875f2e83b","4d2340a5-505a-4a4c-3354-324808558bd9","4d2340a5-505a-4a4c-3654-3448edb4b867"],"type_of_change":"1","version":"4H3Q","vib_list":[{"name":"CP046696","version":"4H3Q.4-7.0.0.15843807"}]}],"id":{"product":"a1d749637b0b455e9a43d66fc6eed023","version":"5579b68a75314dedb93232f769f9f788"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for VMware ESXi - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:01:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version&nbsp; is now available from the following OS-specific URLs:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Linux: EPK74H3Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Working version EPK74H3Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KWZQRおよびVO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25168841","datemodified":"2021-01-28T22:54:08","file_list":["/CP045993_BUILD_5.data","/CP045993.vmexe","/CP045993.vmexe64","/CP045993.vmfile","/CP045993_VMw.zip","/CP045993.xml","/payload.json","/CP045993_VMw.zip/index.xml","/CP045993_VMw.zip/vendor-index.xml","/CP045993_VMw.zip/metadata.zip","/CP045993_VMw.zip/vib20/CP045993/HPE_bootbank_CP045993_HPK5.5-7.0.0.15843807.vib","/CP045993_VMw.zip/metadata.zip/vendor-index.xml","/CP045993_VMw.zip/metadata.zip/vmware.xml","/CP045993_VMw.zip/metadata.zip/vibs/CP045993--4637057696735383209.xml","/CP045993_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045993_HPK5.5-7.0.0.15843807.xml"],"md5sum":"4dc7433ad84be390f15b81e47df6285f","name":"CP045993.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"f77b69a2dbb7375193af4c6b1a72266cb6963df8","size":"24MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"1","version":"HPK5","vib_list":[{"name":"CP045993","version":"HPK5.5-7.0.0.15843807"}]}],"id":{"product":"939eb4c97d9745fe9b103a023bb5c6ab","version":"edb6f39dfca7446691685b8b8eba4e5b"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:22:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0300JDYTH, EH0450JDYTK, and EH0600JDYTL drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0300JDYTH、 EH0450JDYTK、および EH0600JDYTL ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n       Online HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>  <br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>      None</p>"}],"files":[{"bytes":"3646576","datemodified":"2020-12-17T11:22:52","file_list":["cp045508.xml","cpqsetup.exe","HKFLRCD6.rel","payload.json","setup.dll"],"md5sum":"7197becbe6344f8c57a7b46983ae8369","name":"cp045508.exe","release":"2020-12-17T11:10:08","revision":"0","sha1sum":"1cb9fbde176c99d7255a107e7a4875d5f54f23d4","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"da89b89bd1534fddb60af7c195cb4d11","version":"e60e366f57c145abbced01dc920e9ede"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:35:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"362699","datemodified":"2020-06-11T04:18:54","file_list":["/cp044546.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"9b46aa68b1a2f32f667e21e0fc45326b","name":"cp044546.zip","release":"2020-06-11T04:18:10","revision":"0","sha1sum":"e9549e487bb930e39484ea94ccc9a7d88e830293","size":"354KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"c154697a46644c47b9724ee0f9b7eaa4","version":"2c8b05ea902743ac927a92c715bbd21a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5955554","datemodified":"2020-12-13T12:49:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/CP044212.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/HLEAHasseFG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044212.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044212.scexe"],"md5sum":"017506e32694f9364eed1509c0f4dc65","name":"firmware-hdd-059b8654a6-HPG2-6.1.x86_64.rpm","release":"2020-12-13T12:35:04","revision":"0","sha1sum":"976e95acf260494d15d6333d03630cfafb0c4176","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"2","version":"HPG2"}],"id":{"product":"ae7662457b594bb08733bceba6635c72","version":"855cefdaddeb4aa2afdda593ee4c82fb"},"installation":{"command":"CP040337.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-22T14:29:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, only found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5934856","datemodified":"2020-11-04T03:31:25","file_list":["P86_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046140.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"ae77e1abf6efd108f37a6d4636feef22","name":"cp046140.exe","release":"2020-11-04T03:13:05","revision":"0","sha1sum":"f20e071bc409ece374e9bd04379123b336bfe8e0","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"6f3dab1f723a42fab0fcd6264fd8e85f","version":"9eddb46d5476453c8d6f27e7c7c113f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL120 Gen9 (P86)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T02:21:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.04.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.04.07"},{"DeviceName":"HPE 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3262","Version":"03.82.00"},{"DeviceName":"HPE 82Q 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3263","Version":"03.82.00"},{"DeviceName":"HPE 84Q 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532159000FC","Version":"03.82.00"},{"DeviceName":"HPE SN1000Q 16GB 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E7","Version":"06.04.04"},{"DeviceName":"HPE SN1000Q 16GB 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E8","Version":"06.04.04"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4454565","datemodified":"2021-01-22T06:09:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/CP044783.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/Q25A0382.BIN","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/bk017507.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/hld60404.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/mh020407.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.02.01-1.24/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044783.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044783.scexe"],"md5sum":"a2a922f182e8be7ad9249866ac31a6ff","name":"firmware-fc-qlogic-2021.02.01-1.24.x86_64.rpm","release":"2021-01-22T05:57:03","revision":"0","sha1sum":"f990298671bb748dc73210b7f02db5bc9c86708a","size":"4MB","target_guids":["a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4","a6b1a447-382a-5a4f-1077-2532103C3262","a6b1a447-382a-5a4f-1077-2532103C3263","a6b1a447-382a-5a4f-1077-2532159000FC","a6b1a447-382a-5a4f-1077-2031103C17E7","a6b1a447-382a-5a4f-1077-2031103C17E8","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"bca5397d7ba147ddbb0eb4fee4d4d567","version":"10e4bcc6599743a0ad11e967ed4907bb"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター用HPEファームウェアフラッシュ - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb,&nbsp;16 Gb and 32 Gb&nbsp;products.</p>\n\n<ul>\n\t<li>8Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 3.82.00</li>\n\t\t<li>Firmware 8.08.207</li>\n\t\t<li>UEFI 7.00</li>\n\t\t<li>BIOS 3.56</li>\n\t</ul>\n\t</li>\n\t<li>16Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 6.03.00</li>\n\t\t<li>Firmware 8.08.231</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.43</li>\n\t</ul>\n\t</li>\n\t<li>16Gb/32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;\n\t<ul>\n\t\t<li>Package 1.74.07</li>\n\t\t<li>Firmware 9.03.00</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.64</li>\n\t</ul>\n\t</li>\n\t<li>32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;&nbsp;\n\t<ul>\n\t\t<li>Package 02.03.06</li>\n\t\t<li>Firmware 09.04.01</li>\n\t\t<li>UEFI 7.08</li>\n\t\t<li>BIOS 0.0</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5616674","datemodified":"2020-12-13T08:38:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/CP045395.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/STHBT2D5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045395.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045395.scexe"],"md5sum":"36968604d72018fa2fa4d2d070f0c285","name":"firmware-hdd-0a38b25661-HPD5-7.1.x86_64.rpm","release":"2020-12-13T08:25:11","revision":"0","sha1sum":"3f0a6cf440d1e66736d1b960dfd6762a1c2525e0","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"d2428e35050d42c7ba121ca5de5ea63c","version":"326493ca0b1849e991d2bbfc607dcda3"},"installation":{"command":"CP040287.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEMDB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"803358","datemodified":"2021-01-22T10:11:22","file_list":["/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip","/cp044737.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.329.0-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vibs/lpfc-9162685171387925875.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807.xml"],"md5sum":"540104492422fbe829ea10e8e884a09f","name":"cp044737.zip","release":"2021-01-22T10:10:09","revision":"0","sha1sum":"11c6c4adeffa54d01b005b783fd12c2dbce07a6f","size":"784KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7654434b","20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.329.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"14bdb24247e844e783ad854d474aa245","version":"e52c3704acdd42d6ac74c6b5b128a1a4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.6.228.4</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.329.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"Broadcom-ELX-lpfc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"lpfc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20167059","datemodified":"2021-01-28T21:46:02","file_list":["/CP045720_BUILD_4.data","/CP045720.vmexe","/CP045720.vmexe64","/CP045720.vmfile","/CP045720_VMw.zip","/CP045720.xml","/payload.json","/CP045720_VMw.zip/index.xml","/CP045720_VMw.zip/vendor-index.xml","/CP045720_VMw.zip/metadata.zip","/CP045720_VMw.zip/vib20/CP045720/HPE_bootbank_CP045720_HPS1.4-7.0.0.15843807.vib","/CP045720_VMw.zip/metadata.zip/vendor-index.xml","/CP045720_VMw.zip/metadata.zip/vmware.xml","/CP045720_VMw.zip/metadata.zip/vibs/CP045720-2702048989020236456.xml","/CP045720_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045720_HPS1.4-7.0.0.15843807.xml"],"md5sum":"4cf58c5c33fe066420b049099eac2079","name":"CP045720.zip","release":"2021-01-28T21:43:04","revision":"0","sha1sum":"21af6c01744593e0082d16bd743716987d7af48c","size":"19MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1","vib_list":[{"name":"CP045720","version":"HPS1.4-7.0.0.15843807"}]}],"id":{"product":"bc640709bf9a4728898e83ba80473c0a","version":"66e56cbe9bfe433b808e07d33976e1b3"},"installation":{"command":"CP040212.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:49:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD2"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5880014","datemodified":"2020-12-13T15:55:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/CP045472.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/SCIMARRNESD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD2-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045472.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045472.scexe"],"md5sum":"2c209e668dba0b5594c5ada8764a3f9c","name":"firmware-hdd-ae6b41e855-HPD2-3.1.x86_64.rpm","release":"2020-12-13T15:44:07","revision":"0","sha1sum":"e3e73f3b4acbc198ce1d4d8d417b023e22dc439a","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"f66d2f40fe3b49a2ae22ce155e429f5c","version":"fab01c35bd3c46e5bb4fc5754b7c261b"},"installation":{"command":"CP043258.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:20:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.2.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEMDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17639453","datemodified":"2021-01-27T15:46:42","file_list":["/CP045614_BUILD_3.data","/CP045614.vmexe","/CP045614.vmexe64","/CP045614.vmfile","/CP045614_VMw.zip","/CP045614.xml","/payload.json","/CP045614_VMw.zip/index.xml","/CP045614_VMw.zip/vendor-index.xml","/CP045614_VMw.zip/metadata.zip","/CP045614_VMw.zip/vib20/CP045614/HPE_bootbank_CP045614_HPD5.3-7.0.0.15843807.vib","/CP045614_VMw.zip/metadata.zip/vendor-index.xml","/CP045614_VMw.zip/metadata.zip/vmware.xml","/CP045614_VMw.zip/metadata.zip/vibs/CP045614--8195136210944367806.xml","/CP045614_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045614_HPD5.3-7.0.0.15843807.xml"],"md5sum":"b5bfc7f558ba99cc883b8b5e1ddaf6af","name":"CP045614.zip","release":"2021-01-27T15:44:04","revision":"0","sha1sum":"3c55e66e6bea158781877f1b9da34b84947571f8","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP045614","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"8881b9f92866499daac317541d2299ed","version":"4063ecb214f240cfb6a3a5dbd7c8b2cc"},"installation":{"command":"CP040573.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:18:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1052"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The x64 Smart Component provides firmware for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\nOnline ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1052<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1047<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support to the RDE-Alerts feature</p>\n\t</li>\n\t<li>Support for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"1341860","datemodified":"2021-02-25T02:34:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/CP044417.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/HPE_NS204i_Gen10P_1052.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.0.14.1052-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044417.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044417.scexe"],"md5sum":"b33b9e578973bf555994c4f73f010b81","name":"firmware-9041739931-1.0.14.1052-1.1.x86_64.rpm","release":"2021-02-25T02:26:04","revision":"0","sha1sum":"a6e664d6cc5342bdc4a4d7316a6e694695c1af2b","size":"1MB","target_guids":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"type_of_change":"1","version":"1.0.14.1052"}],"id":{"product":"521144c543434ae9b4777bf076b798c5","version":"9b78901c4d1543e782a0fa93a04b63bc"},"installation":{"command":"CP044417.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044417.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-9041739931-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP044417.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-9041739931-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-9041739931-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-9041739931-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Flash for Linux(x64) - HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030f","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030e","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"0310","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-224115900310","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-25T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Firmware Smart Component release for HPE Gen10+ Boot Controller</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support to the RDE-Alerts feature</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"03101590","sw_key_expectedpath":"firmware:sd:"},{"name":"030E1590","sw_key_expectedpath":"firmware:sd:"},{"name":"030F1590","sw_key_expectedpath":"firmware:sd:"},{"name":"02F61590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"319902","datemodified":"2021-01-14T08:20:33","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"de3c2678b31541308de26f8eea283e22","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel7u9.x86_64.rpm","release":"2021-01-14T07:51:05","revision":"0","sha1sum":"b40da9b184f458badf86ed73361d7a3f7fc183b9","size":"312KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"319889","datemodified":"2021-01-14T08:08:45","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"4f578806361dbc760ea2ee88327d5bbe","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel7u8.x86_64.rpm","release":"2021-01-14T07:51:05","revision":"0","sha1sum":"bf3a3371d7bab25d2320259df27b0a155b210857","size":"312KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"8f50751a2a4c4c6eac4753b883c9d78b","version":"262c2c428cc447eebcaf0976442857d2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 Update 8</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6285696","datemodified":"2020-10-29T15:15:10","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/CP046126.xml","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/U13_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u13-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046126.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046126.scexe"],"md5sum":"ef8275b10e0e07e5c04416db35ba06cf","name":"firmware-system-u13-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-29T15:06:05","revision":"0","sha1sum":"6b7542ae25c1a4d7a2ca51a0097f9ef4e5b2cb07","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"b5d6bf00c2934921ba03955fbaab210d","version":"07f43cb1b1034888acccbe5d64f7756f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230a/XL250a Gen9(U13)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T17:39:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"901102","datemodified":"2021-01-22T09:58:28","file_list":["/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip","/cp044779.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/doc/README.txt","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_4.1.22.0-1OEM.700.1.0.15843807.vib","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vibs/qlnativefc--1613597594131483861.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/bulletins/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807.xml"],"md5sum":"43706e403bf3dc454864764ef6f169e2","name":"cp044779.zip","release":"2021-01-22T09:57:04","revision":"0","sha1sum":"7bfe42765d4a45e5a5668b7364a7c3d963e13fed","size":"879KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"4.1.22.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"c07f99c2b0d248348543770e8f33efd1","version":"c0a0fdffc7e04965a04cd2721223395e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Driver version 4.1.9.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Driver version 4.1.22.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:4.1.22.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-QLogic-FC:4.1.22.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045275.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2625392","datemodified":"2020-11-05T06:25:50","file_list":["cp045275.compsig","cp045275.zip","cp045278.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"7ad2cf5bba60dfe10e1deca505775aad","name":"cp045278.exe","release":"2020-11-05T06:24:11","revision":"0","sha1sum":"1d16260cdc148c7a84ef0ce6743f0be7a5d59730","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"d9b51eadf7e440fc88f26963aec59690","version":"56640a6e9f804447a67cb1eedd5d39a4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T03:15:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2012, Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>10GbE VBD driver version 7.13.196.0</li>\n\t<li>NDIS 6.0 driver version 7.13.183.0</li>\n\t<li>FCoE offload driver version 7.14.20.0</li>\n\t<li>iSCSI crash dump driver version 7.13.4.0</li>\n</ul>\n"}],"files":[{"bytes":"3443984","datemodified":"2021-01-08T08:42:35","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp044989.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"md5sum":"12ab90ed23fba90c4c8c4fd4b8a91d3e","name":"cp044989.exe","release":"2021-01-08T08:21:06","revision":"0","sha1sum":"a3f7e5d27e20711baf476a4ba7c579a09ffe6406","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"0","version":"7.13.196.0"}],"id":{"product":"88920b6128524213bc79e665d9b3a53b","version":"d21ea45df7174660b13687dc9b581f05"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"2231","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c2231","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD）that thread&#39;s saved floating-point state is invalid when executed Network stress.&nbsp;</li>\n\t<li>This product correct an issue which failed to generate Internet Small Computer System Interface(iSCSI) Crash dump in Secure Boot enabled.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where the vSwitch unavailable to assign on WS2012R2.</li>\n\t<li>This product correct an issue which fixes One time system crash seen while uninstalling NDIS driver</li>\n\t<li>This product addresses an issue where an SR-IOV virtual function can&#39;t to start normaly.&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"359625","datemodified":"2020-06-11T04:20:11","file_list":["/cp044545.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"73a836ddc98f3eb98525843514c008a6","name":"cp044545.zip","release":"2020-06-11T04:19:09","revision":"0","sha1sum":"bf360b6dd6202191a5a4acf53d1b0e689415ee3f","size":"351KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"8c5c6a0f19974bc4868c84a832f1b780","version":"d1989fededf14742a3977e71fe62ea9e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1782723","datemodified":"2021-01-22T05:07:18","file_list":["./opt/emulex/sles12sp5/i386/lib/libdfc.so","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12.8.316","./opt/emulex/sles12sp5/i386/lib/libemsdm.so","./opt/emulex/sles12sp5/i386/lib/libemulexhbaapi.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/sles12sp5/x86_64/lib64/libemsdm.so","./opt/emulex/sles12sp5/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.316","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"9b461d0aeac17e69aa62af5b49a91527","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.sles12sp5.x86_64.rpm","release":"2021-01-22T05:04:45","revision":"0","sha1sum":"6501dcd58438c59d89b0b8a4b5f1863f250894e3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"},{"bytes":"1782486","datemodified":"2021-01-22T05:13:00","file_list":["./opt/emulex/sles12sp4/i386/lib/libdfc.so","./opt/emulex/sles12sp4/i386/lib/libdfc.so.12","./opt/emulex/sles12sp4/i386/lib/libdfc.so.12.8.316","./opt/emulex/sles12sp4/i386/lib/libemsdm.so","./opt/emulex/sles12sp4/i386/lib/libemulexhbaapi.so","./opt/emulex/sles12sp4/x86_64/lib64/libdfc.so","./opt/emulex/sles12sp4/x86_64/lib64/libdfc.so.12","./opt/emulex/sles12sp4/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/sles12sp4/x86_64/lib64/libemsdm.so","./opt/emulex/sles12sp4/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.316","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"14f3113df1c0010fdb8fbc333b36ed3a","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.sles12sp4.x86_64.rpm","release":"2021-01-22T05:04:45","revision":"0","sha1sum":"05a28361719cef5a552f2dd6413bf97e0641cb2a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"489fcd07381047728f0d8307f128b6be","version":"6031795a2e384fbc94adde80cc775cc8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 12 service pack&nbsp;4 and SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.6.272.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5374872","datemodified":"2020-11-25T11:13:01","file_list":["/CP044762_BUILD_14.data","/CP044762.vmexe","/CP044762.vmexe64","/CP044762.vmfile","/CP044762_VMw.zip","/CP044762.xml","/payload.json","/CP044762_VMw.zip/index.xml","/CP044762_VMw.zip/vendor-index.xml","/CP044762_VMw.zip/metadata.zip","/CP044762_VMw.zip/vib20/CP044762/HPE_bootbank_CP044762_2021.02.01.14-6.5.0.4240417.vib","/CP044762_VMw.zip/metadata.zip/vendor-index.xml","/CP044762_VMw.zip/metadata.zip/vmware.xml","/CP044762_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044762_2021.02.01.14-6.5.0.4240417.xml","/CP044762_VMw.zip/metadata.zip/vibs/CP044762--1498640736127192772.xml"],"md5sum":"ddde0e9c36bb5aa6f6d74db2ef3ddfde","name":"CP044762.zip","release":"2020-11-25T11:09:04","revision":"0","sha1sum":"8d4facf2ba51339d1e7aecbd3f5311ec46da664d","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044762","version":"2021.02.01.14-6.5.0.4240417"}]}],"id":{"product":"a5a34b70caa4482380a015cc4a6e9c97","version":"f4d3a30cbe304a819a06cd5176ce1fe2"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>12.60a4</td>\n\t\t\t<td>2.10X6</td>\n\t\t\t<td>12.6.284.0</td>\n\t\t\t<td>12.6.302.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.7</td>\n\t\t\t<td>12.6.271.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEML and MB4000JFEMN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB2000JFEMLおよびMB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17337883","datemodified":"2021-01-28T11:42:51","file_list":["/CP045654_BUILD_5.data","/CP045654.vmexe","/CP045654.vmexe64","/CP045654.vmfile","/CP045654_VMw.zip","/CP045654.xml","/payload.json","/CP045654_VMw.zip/index.xml","/CP045654_VMw.zip/vendor-index.xml","/CP045654_VMw.zip/metadata.zip","/CP045654_VMw.zip/vib20/CP045654/HPE_bootbank_CP045654_HPD6.5-7.0.0.15843807.vib","/CP045654_VMw.zip/metadata.zip/vendor-index.xml","/CP045654_VMw.zip/metadata.zip/vmware.xml","/CP045654_VMw.zip/metadata.zip/vibs/CP045654--6094952109782790795.xml","/CP045654_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045654_HPD6.5-7.0.0.15843807.xml"],"md5sum":"542ac19dec56d41fb9cd9a9207a8d7e0","name":"CP045654.zip","release":"2021-01-28T11:40:05","revision":"0","sha1sum":"724f9223cdc06eac8fe29879ddc7c3f7ff21fd97","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6","vib_list":[{"name":"CP045654","version":"HPD6.5-7.0.0.15843807"}]}],"id":{"product":"193fefc836ff47bc98df145955f3145a","version":"74b8992a809c47cd8be5f9fa46e89e47"},"installation":{"command":"CP040640.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"},{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:53:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11563936","datemodified":"2021-01-28T09:40:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/CP046634.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/U34_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046634.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046634.scexe"],"md5sum":"886cd78255bc525e69a083afa8231533","name":"firmware-system-u34-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T09:28:06","revision":"0","sha1sum":"10b50220b955717129795429bfa166fbd05481eb","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"0fb6a42a8b224caba8a145e0ac696d52","version":"f07847af517e4aebb7662432470c0222"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10（U34）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK73H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK73H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK73H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK73H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK73H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK73H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3  Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、 MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、 MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-000H3ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK73H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problem Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"9499901","datemodified":"2021-01-23T12:45:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/CP046392.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/MPK73H5Q.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK73H5Q-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046392.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046392.scexe"],"md5sum":"1147ce6e6efcb3d1f1f2542314eae691","name":"firmware-hdd-e320db791d-MPK73H5Q-1.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"07926aaf57fa74326847f01e1ead9e5132f14295","size":"9MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"1","version":"MPK73H5Q"}],"id":{"product":"5b139cd72d0b4c89818f276c3a1dce8c","version":"e941f1092f934ef9ae42bad70c9e5801"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-15T05:57:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000240GWCEU、MK000480GWCEV、MK000960GWCFA、およびMK001920GWCFBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MK000240GWCEU, MK000480GWCEV, MK000960GWCFA&nbsp;and MK001920GWCFB&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4639152","datemodified":"2020-12-13T14:31:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/CP045448.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/GS863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045448.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045448.scexe"],"md5sum":"c4843ca67ad47d14c4016b3d7b5ff849","name":"firmware-hdd-7677644a25-HPG3-6.1.x86_64.rpm","release":"2020-12-13T14:20:08","revision":"0","sha1sum":"f38d2e573ccacd5ffec9639b7f9c3d4151bfbf2e","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"8da11b65fc4a442eb7c1c3ce3ad367bb","version":"3d1364bbad764ba684bbf773e9aca55e"},"installation":{"command":"CP040341.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX3 Ethernet NICs for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX3 Ethernet NIC for Windows Server 2012 R2用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"18538408","datemodified":"2019-10-08T04:01:32","file_list":["cp040882.xml","cpqsetup.exe","cp_data.xml","ibbus.sys","install.xml","ipoib6x.cat","ipoib6x.inf","ipoib6x.sys","MLNX_VPI_WinOF-5_35_HP_win2012R2_x64.exe","mlx4eth63.cat","mlx4eth63.inf","mlx4eth63.sys","mlx4_bus.cat","mlx4_bus.inf","mlx4_bus.sys","mlx_setup.dll","ndfltr.sys","nicdrvr.dll","RestartDriver.exe","Tenable-Upgrade.ps1","winctxtune_bus.dll","winctxtune_eth.dll","winctxtune_ipoib.dll","winmad.sys","winverbs.sys"],"md5sum":"a75dc6db150a2adb363abf5ae3abc407","name":"cp040882.exe","release":"2019-10-08T03:46:02","revision":"0","sha1sum":"9bed88d49c6955d286c8df06468a6949eecb9013","size":"17MB","target_guids":[],"type_of_change":"0","version":"5.35.12978.0"}],"id":{"product":"3de1667723914ad89f6c44c12d89171b","version":"0ecf0c72db94499c82c18762aefa5a19"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟和目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>설치 버튼을 클릭하여 설치 작업을 시작합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击安装按钮继续执行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox CX3 Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Mellanox CX3ドライバーfor Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed an issue where the link speed of an IPoIB adapter was the actual speed and not the official speed (i.e. 54.3GB/s instead of 56 GB/s).<br />\nFixed an issue where firmware burning failed on servers with Connectx-3 and Connectx-4 devices.<br />\nFixed an issue were Mellanox counters in Perfmon did not work over HPE devices.<br />\nFixed an issue that caused the installation process to hang while checking if the RDSH service is installed.<br />\nFixed an issue where a SR-IOV team failure was caused by an unsuccessful adapter parameters update.<br />\nFixed a crash in the driver properties dialog in the case where more than 8 teaming ports were defined.<br />\nFixed an issue which reported a false error for successful netsh tcp settings via performance tuning.<br />\nFixed a crash which could occur during virtual function initialization.<br />\nDeactivated the RDMA statistics counters query for vPorts for which RDMA is not enabled.<br />\nFixed the issue which caused the failure of the powershell command Get_MLNXNetAdapterSettings and the command Get_MLNXNetAdapterFlowControlSettings on servers with Connectx3/Pro and ConnectX4/LX devices.<br />\nFixed a crash which could occur during driver initialization.<br />\nFixed an issue that generated and sent an erroneous message to the Windows event log when using firmware 2.36.5000 whenever &quot;Mellanox WinOF Bus Counters&quot; was selected in Perfmon.<br />\nFixed an issue that occasionally caused system-hang when TCP offload parameters were updated dynamically while SR-IOV was enabled.<br />\nFixed an issue that occasionally caused system-hang upon bus driver disabling, when the encapsulation parameters were updated dynamically while SR-IOV was enabled.<br />\nFixed an issue where the virtual function RDMA was not functional when vSwitch was attached to port 2. Now RDMA over VF is supported only when the vSwitch is attached to port 1.<br />\nFixed an issue which caused the driver to hang during installation process.</p>\n"},{"curr_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"mlx4_bus.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6247560","datemodified":"2020-11-05T04:32:51","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/CP046169.xml","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/U15_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u15-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046169.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046169.scexe"],"md5sum":"e76ef45ad94dc364494acf2da08430e7","name":"firmware-system-u15-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-05T04:23:06","revision":"0","sha1sum":"54c57e367fd0f069a2bc4bee46265ce7b5eb7b26","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"aba50894270544dcaa9bf4eb0a273b8c","version":"9755702c7b1b4b6bae4d73212fc39cc9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T07:10:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.16.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.16"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2224544","datemodified":"2020-10-15T06:56:14","file_list":["cp041524.xml","cpqsetup.exe","payload.json","setup.dll","UBM2_V1.16.hex.fw"],"md5sum":"5e17f60bca002c61340e2e06957268a3","name":"cp041524.exe","release":"2020-10-15T06:39:10","revision":"0","sha1sum":"887a0fee5d08b179e7a39c6a4c7891fcf9ce1280","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.16"}],"id":{"product":"52d86414c1094be5a91709cfda5fa592","version":"e51b215c9ab3435685e5ead8d2dd6d9c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Firmware update takes effect immediately.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10Plus UBM2 バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-24T06:39:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.78-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.78"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.78-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.78"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 4200 Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.78 (A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.50(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;&nbsp;Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"10225822","datemodified":"2019-01-24T07:28:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/CP038809.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/Tiburon-Release-1.78-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/libsetup2.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/setup2","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/storcli-1.25.12-1.noarch.rpm","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.78-1.1/supplement","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP038809.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP038809.scexe"],"md5sum":"ac3a6382381d2688b4b7e0c14c0c8bcb","name":"firmware-smartarray-f18fdefd0b-1.78-1.1.x86_64.rpm","release":"2019-01-24T13:22:01","revision":"0","sha1sum":"85f058e49379b1fca0d2fd5540d8136e660f6d90","size":"9MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"0","version":"1.78"}],"id":{"product":"63b5acd6b69146b7aacdd66e3c7732d6","version":"53a437585e814589a15f7d22f2fcaf9c"},"installation":{"command":"CP038809.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP038809.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f18fdefd0b-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP038809.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f18fdefd0b-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 4200バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-02-23T09:21:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for the HPE Apollo 4200 Gen10 Server</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.80"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.80"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.80"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.80&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP Ethernet 10Gb 2-port 530SFP+ Adapter<br />\n\t\t\tHP Ethernet 10Gb 2-port 530T Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.8.2</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<p>HP Ethernet 10Gb 2-port 533FLR-T Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />\n\t\t\tHPE FlexFabric 10Gb 4-port 536FLR-T Adapter<br />\n\t\t\tHP StoreFabric CN1100R Dual Port Converged Network Adapter<br />\n\t\t\tHPE StoreFabric CN1100R-T Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.8.2</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3250862","datemodified":"2021-01-21T08:04:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/CP044813.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/CP044813.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/nic_fw/hp_mbi_7.18.80.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.28.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044813.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044813.scexe"],"md5sum":"ad655f2ca2d473ce771e579079ae3703","name":"firmware-nic-qlogic-nx2-2.28.6-1.1.x86_64.rpm","release":"2021-01-21T07:50:05","revision":"0","sha1sum":"1197f0f0c9b0a0e264a33be5d2cdcb058cc2818a","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"0","version":"2.28.6"}],"id":{"product":"5f7dae044b3b4d97823b1cfc69305837","version":"e5e4d0dc4f5e4d879e27269e435db546"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP044813.txt file.The results of the firmware upgrade are saved&nbsp;in CP044813.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE QLogic NX2 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE QLogic NX2 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the Firmware installation failure when enabling secure boot under SUSE Linux Enterprise Server 15 SP2.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue that platform would be randomly waked up by WOL packet.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEeD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG1800JFHMH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3020600","datemodified":"2020-12-17T12:42:00","file_list":["cp045502.xml","cpqsetup.exe","payload.json","setup.dll","T14SEeD7.REL"],"md5sum":"806e9e3257f83e96a972b0548bed4d0c","name":"cp045502.exe","release":"2020-12-17T12:31:13","revision":"0","sha1sum":"c28d39b82f6c168c04a9fb5695e34e5614fb9453","size":"2MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"cb2be7d18951448db0daf6ce3cff2a1c","version":"3c9f436e6008438b8854a4ecf00eae9c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JFHMH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:32:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_OCP_2p24_NCSIwPLDMoMCTP_800059D4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"2.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td>\n\t\t\t<td>800059D4</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>2.24</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2839.0 includes: Intel(R) Boot Agent ICE v2.2.01 &amp; UEFI x64 100 gigabit driver v2.2.07.</p>\n"}],"files":[{"bytes":"10516437","datemodified":"2021-01-21T10:43:14","file_list":["HPE_E810_CQDA2_OCP_2p24_NCSIwPLDMoMCTP_800059D4.HPb","HPE_E810_CQDA2_OCP_2p24_NCSIwPLDMoMCTP_800059D4.xml","payload.json"],"md5sum":"77c3dce362b2b0d434842e39690ec184","name":"HPE_E810_CQDA2_OCP_2p24_NCSIwPLDMoMCTP_800059D4.fwpkg","release":"2021-01-21T10:39:07","revision":"0","sha1sum":"2846985f48ef4f2441d5bf5ff81cbd8389d501cb","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159280860006"],"type_of_change":"1","version":"2.24"}],"id":{"product":"dc41774861a945f28d388059e656b2ca","version":"be413fccc81745d583654fcc0ddcaaf3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"INTEL_E810_CQ2OCP_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"本套件包含可升級 HPE ProLiant QLogic FastLinQ Gigabit 乙太網路網路卡 韌體的公用程式和二進位檔，適用於 Linux x86_64 平台。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE ProLiant QLogic FastLinQ 기가비트 이더넷 NIC 펌웨어를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"此软件包含有用于升级在Linux x86_64平台下运行的HPE ProLiant QLogic FastLinQ千兆以太网卡固件所需的实用程序和二进制文件。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v8.55.12. This combo image includes: Boot Code (MFW): 8.55.21.0, UEFI: 4.1.11.2&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>\n"}],"files":[{"bytes":"2227405","datemodified":"2021-01-21T06:50:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/CP044810.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/CP044810.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/nic_fw/ql_hp_ah_mbi_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.10.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044810.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044810.scexe"],"md5sum":"216f025077fbe005c7361d4597012f0f","name":"firmware-nic-qlogic-flq-1.10.10-1.1.x86_64.rpm","release":"2021-01-21T06:39:04","revision":"0","sha1sum":"34e449884f0fbb6c3dc824ca2d7351cf22c42271","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"0","version":"1.10.10"}],"id":{"product":"a2c850b33a31462c8693efedafbdd8b9","version":"7761c1b3fae845228e5a11aacf6408a0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP044810.txt file.The results of the firmware upgrade are saved&nbsp;in CP044810.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n\t<li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE QLogic FastLinQ 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE QLogic FastLinQ 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE QLogic FastLinQ 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects the abnormal disconnection of iLO web page while performing under Shared Networking on Flexible-LOM.</li>\n\t<li>This product addresses an issue where the HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 adapter and &nbsp;HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter UMCE (Uncorrectable Machine Check Exception) was followed by Unrecoverable I/O error, Uncorrectable PCI express error on Server and one of the ports suddenly no longer can send or receive traffic.</li>\n\t<li>This product addresses an issue where driver doesn&rsquo;t load upon booting up by correct memory relocation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for Windows Server 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4472568","datemodified":"2020-12-11T18:33:19","file_list":["cp045204.xml","cpqsetup.exe","GPM883G4.rel","payload.json","setup.dll"],"md5sum":"38f60d94b8cda22f70a623f45906e7ff","name":"cp045204.exe","release":"2020-12-11T18:24:08","revision":"0","sha1sum":"902e496e3ccc31e110c28631ea7e5dd6e592a14f","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"b2ba8bbc89f8475a9e824abb19fcc091","version":"113df3e43450407bbf5bb64a491d3b23"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T15:39:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"4123536","datemodified":"2020-12-17T05:48:14","file_list":["cp045526.xml","cpqsetup.exe","HVLPeAsseFD1.rel","payload.json","setup.dll"],"md5sum":"4b8bdfb79def8e92987ad34dc80b0746","name":"cp045526.exe","release":"2020-12-17T05:40:05","revision":"0","sha1sum":"7f4cacee52740ff3f16b3f134c6ee8e9ee10a902","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"3f71b29f23c14fcb8f1f4cc9ac53400c","version":"5022dcd5d6504b74a776027b358405fe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:41:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33578712","datemodified":"2021-02-25T12:45:13","file_list":["A47_2.40_02_23_2021.signed.flash","A47_2.40_02_23_2021.xml","payload.json"],"md5sum":"5e125d33a2e3ed717789fdd566a5309d","name":"A47_2.40_02_23_2021.fwpkg","release":"2021-02-25T12:41:04","revision":"0","sha1sum":"07531395dc362acc1a3d8314ebdcedc59aa26290","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"0","version":"2.40_02-23-2021"}],"id":{"product":"74593c8509e24398998a42d78a910462","version":"0e5e497eea4b4368ab6727513935b3c6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-04T22:41:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support for Direct Liquid Cooling solution.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>HPE ProLiant XL675d Gen10Plus CPLD version 0F<p>HPE Apollo 6500 Gen10 Plus Chassis CPLD version 0909<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.18.31"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.18.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2012 R2、Windows Server 2016およびWindows Server 2019で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"5628896","datemodified":"2021-02-09T08:11:56","file_list":["bcmnicfwupg.exe","BMAPIa.dll","cp045014.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"cc1b80b9c0d7c9e8623c9be2c55885fc","name":"cp045014.exe","release":"2021-02-09T08:04:06","revision":"0","sha1sum":"195b17576e50cf0a058a00044c1213a7a26a99fd","size":"5MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"C9279","version":"bb7012258996420cb71c7f833a304bfc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"214.0.0.0","description":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 <BR>\n<P>[インストール]ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the wrong spare number while it was originally not the same as what was written on the label of package.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product addresses an issue about lack of information under AHS log.</li>\n\t<li>This product addresses an RSOD issue which appeared intermittently during POST after having a warm reboot.</li>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BcmNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1033120","datemodified":"2021-01-08T20:08:44","file_list":["cp045874.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt68x64.cat","ixt68x64.din","ixt68x64.inf","ixt68x64.sys","ixtmsg.dll","nicdrvr.dll"],"md5sum":"d5bea19b3c46f33debcbae2f5e32c246","name":"cp045874.exe","release":"2021-01-08T19:47:05","revision":"0","sha1sum":"79e43d7defb38e252369bff389e8ec1bd6616721","size":"0MB","target_guids":[],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"47e104da8d1247009422e246e7ae204a","version":"d7b50fb0b8a3400b9b25b995852e8633"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020101","value":"HPE Superdome Flex Server"}],"sw_keys":[{"name":"ixt68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"AC963EEB-ED78-4F36-8CC1-29D85F34A0AC","Devices":{"Device":[{"DeviceName":"HPE 16GB NVDIMM Single Rank x4 DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hpe_16gib_skh_v1_04_2666.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-80AD-80AD80AD80AD","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This firmware package provides updated firmware for HPE 16GB NVDIMM-N DDR4-2666 Modules. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"113235","datemodified":"2018-08-31T03:57:51","file_list":["hpe_16gib_skh_v1_04_2666.bin","nvdimm-16gb_1.04.xml","payload.json"],"md5sum":"c720eca612222d7197cfdf3887ab887d","name":"nvdimm-16gb_1.04.fwpkg","release":"2018-08-31T08:57:03","revision":"0","sha1sum":"a1b3f97834562f8b81c9e85abdb02cb0d37ea400","size":"110KB","target_guids":["805DD01C-EB5A-1E76-80AD-80AD80AD80AD"],"type_of_change":"1","version":"1.04"}],"id":{"product":"058a033acd864749bc51a480576695e0","version":"63108f5b31a34e41bf083831da5b9550"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the <strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant</a></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-09-30T08:53:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>Initial relaese.</p>\n"},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>Initial relaese.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3740142","datemodified":"2021-01-09T00:55:03","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-i40e","./lib/modules/4.12.14-94.41-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"6c3b920ed47523234ee1ac58cf9edecb","name":"hp-i40e-kmp-default-2.13.10_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T00:47:06","revision":"0","sha1sum":"f6edb52ee704cb391b169048d19d084445613a52","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.13.10-1"},{"bytes":"3896917","datemodified":"2021-01-09T00:59:55","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-i40e","./lib/modules/4.12.14-120-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"9b48a6540b96617604cae3ddb2360376","name":"hp-i40e-kmp-default-2.13.10_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T00:47:06","revision":"0","sha1sum":"6979f4605dd5b21378bbb696907bd5330e98a634","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.13.10-1"}],"id":{"product":"9cc198d5db9a4dc58d7191dc280dcc88","version":"cee7101386584a9b95021d96063ef93a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</li>\n\t<li>This product corrects an issue which querying DCB configuration data failed on Intel Carslville controller if driver probe or set &nbsp;at 2.5/5G speed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product supports new feature called software DCB(Data Center Bridging) which allows using DCB without firmware LLDP(Link Layer Discovery Protocol) agent being turned on.</li>\n\t<li>This product supports new feature which allows user to specify VLAN(Virtual Local Area Network) field and add it to flow director via ethtool</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where server hungs after loading XDP(eXpress Data Path) program in case of LLDP(Link Layer Discovery Protocol) agent disabled&nbsp;</li>\n\t<li>This product addresses an issue where it is not possible to change MAC(Media Access Control) address on VF(Virtual Function) from VM(Virtual Machine) when VF is in trusted mode</li>\n\t<li>This product addresses an issue where it cannot create VF(Virtual Function) VLAN(Virtual Local Area Network) interface inside a namespace&nbsp;</li>\n\t<li>This product addresses an issue where system crash during removing driver when VSI(VIrtual Station Interface) is in reset recovery mode</li>\n\t<li>This product addresses an issue where VF(Virtual Function) receives unicast packets from other VF</li>\n\t<li>This product addresses an issue where using Intel nvmupdate utility never ending update</li>\n\t<li>Thips product addresses an issue where kernel crash in vf driver(iavf) reset when pf driver(i40e) is removing</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3389696","datemodified":"2020-12-11T21:51:58","file_list":["cp045578.xml","cpqsetup.exe","G1633HD8.rel","payload.json","setup.dll"],"md5sum":"cb9df761b27a02948bb690aadee4a948","name":"cp045578.exe","release":"2020-12-11T21:43:04","revision":"0","sha1sum":"80d2f560c9547e52e101988751a7420488a4e57a","size":"3MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"2ce3ac2092b94fa1b8631b7964992fb7","version":"526df3e1023b4f539e3eadd8dd8a4c14"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO007680JWCNK and VO015300JWCNL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:01:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, LSI_SAS2, provides Windows Server 2012 R2 support for HPE H2xx SAS/SATA Host Bus Adapter."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1101576","datemodified":"2017-05-24T05:21:28","file_list":["cp032453.xml","cpqsetup.exe","driverconfigparam.def","generic.dll","install.xml","lsinodrv.inf","lsi_sas2.cat","lsi_sas2.inf","lsi_sas2.pdb","lsi_sas2.sys","lsi_sas2_win8.1_2012R2.txt","wdcfg.exe"],"md5sum":"c15d5383a67e23993ac74c9970188045","name":"cp032453.exe","release":"2017-05-24T05:20:05","revision":"0","sha1sum":"a7af52dfbe25436925f11b7be166a5c5f155ca50","size":"1MB","target_guids":[],"type_of_change":"0","version":"2.68.64.1"}],"id":{"product":"4ac92b6d48fb46ccad998db868b37deb","version":"bc7c672fa5b049139b43eed635d3c80d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for Microsoft Windows Server 2012 R2 64-bit Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-06-12T00:35:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for:</p>\n\n<ul>\n\t<li>Microsoft Windows Server 2016 - Server Core and Server with a Desktop.</li>\n</ul>\n\n<p><strong>Note:</strong> Revised component package. No change to driver functionality resulting from the change. If system has previously updated to driver version 2.68.64.2, then it is not necessary to update to 2.68.64.2(A).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2.68.64.1(B)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If driver version 2.68.64.1 was previously installed, then it is not necessary to upgrade to version 2.68.64.1(B).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Enhancements/New Features implemented in version 2.68.64.1</strong>:</p>\n\n<ul>\n\t<li>Added support for Windows 8.1 and Windows Server 2012R2 to the build scripts.</li>\n\t<li>Add build support for new Windows Event Logging.</li>\n\t<li>Add support for automatic selection of the default driver build parameters file during the build</li>\n</ul>\n\n<p style=\"margin-left:1.0in\">&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"lsi_sas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653436A-HDAI OCP3 PCIe4 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000593</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5525084","datemodified":"2021-02-25T13:37:19","file_list":["20_29_1016-MCX653436A-HDA_HPE_Ax.pldm.signed","20_29_1016-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"fb762bc90084ffb38eceeaaff70695d3","name":"20_29_1016-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:34:06","revision":"0","sha1sum":"05663c7d6a5700fa2549247cadd5722e2449bad6","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900348"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"3f4d9eceae63421389745abdf06f001a","version":"a3b51156c8c64053b6fbb31c0524ebce"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653436A-HDAI OCP3 PCIe4 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-05T17:07:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6300520","datemodified":"2020-11-05T04:48:27","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/CP046154.xml","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/U20_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u20-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046154.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046154.scexe"],"md5sum":"2154c51c45b302fa58edeaf6596d4540","name":"firmware-system-u20-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-05T04:38:06","revision":"0","sha1sum":"8447139ff2a503540941f254f2ffaa9ff01fc435","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"5a6728d6569a49b58900b480fe0325b7","version":"0dc867eb99334cfba3a3a8a17cdc85d9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen9/DL180 Gen9（U20）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T09:21:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"StorCLI は複数のユーザーが MegaRAID® 製品の維持、トラブルシューティング、および構成の機能の実行を可能にするコマンド ライン インターフェイスです。 ストレージ構成の作成と管理をすることもできます。 StorCLI はコント ローラー上のコント ローラー カード、仮想ドライブ、そしてドライブのステータスを表示することができます。 CLI を使用してコント ローラーのファームウェアのアップデートなどのシステム メンテナンス タスクを実行することができます。 このツールはコント ローラーの監視とコント ローラーの仮想ドライブおよびドライブを構成することを可能にします。 簡単に新しいストレージ構成を作成したり構成を変更することができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2720776","datemodified":"2018-12-13T08:53:58","file_list":["cp036918.xml","cpqsetup.exe","install.xml","multisetup.dll","StorCLI.msi"],"md5sum":"daa7af959475b91876166f241663c9cc","name":"cp036918.exe","release":"2018-12-13T14:52:03","revision":"0","sha1sum":"2a697a4105185dd1a119701b42c3b8130989b75e","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"type_of_change":"0","version":"1.25.12.0"}],"id":{"product":"42eb0b14ee764418a766256ac492f5b9","version":"16db44a089104cfb9cf6570d36545834"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n\n<p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p>\n\n<p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバーのWindowsオペレーティングシステムからStorcliユーティリティを実行するには：</strong></p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>\n\n<p>インストールが完了したら、コマンドプロンプト環境を実行し、%programfiles%\\MR Storage Administrator\\StorCLI\\binフォルダーに移動し、Storcli64.exeユーティリティを実行します</p>\n\n<p>例：<strong>Storcli64.exe /c0 show </strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit"},{"lang":"ja","x_late":"Windows 64-bit用HPE MegaRAID Storage Administrator StorCLI"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-08-05T15:31:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Release For Snap4</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server (private)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"storcli64.exe","sw_key_expectedpath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.2829.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE\r\n\r\n","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.2829.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.2839.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of Intel NIC firmware running under Microsoft Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6982456","datemodified":"2021-01-21T09:39:57","file_list":["cp044897.xml","cpqsetup.exe","FW/","FW/BootIMG_ISA.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP_ISA.txt","FW/HPE_i350T4_K68277_80001099.txt","FW/HPE_i350T4_OCP_K53978_80001097.txt","FW/HPE_I350_2p_Cu_NCSI_1.61_8000108E.txt","FW/HPE_I350_4p_Cu_NCSI_1.61_8000108F.txt","FW/HPE_X710DA2_8p10_CFGID7p2_K97470_800093DD.bin","FW/HPE_X710DA2_OCP3_8p10_CFGID7p2_K97342_80009837.bin","FW/HPE_X710_DA_OCP3_EEPROM_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"ed37db61b8490f791e971985a7512998","name":"cp044897.exe","release":"2021-01-21T09:26:04","revision":"0","sha1sum":"040a214e475985f12d124619f70dc0bd13d660b4","size":"6MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"0b5ea35199d249309413cdf1ab404c23","version":"a887105ee21c42b9863a6cbd4a4dca36"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ OCP3 Adapter for HPE</li>\n\t<li>Intel X710-DA2 Ethernet 10Gb 2-port SFP+ Adapter for HPE&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product correct an issue which fixes OROM downgrade failed from older version with exit code 6&nbsp;</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"19300214","languages":[{"lang":"en","x_late":"Firmware (Entitlement Required) - Storage Controller"},{"lang":"ja","x_late":"ファームウェア (ライセンスが必要) - ストレージコントローラー"}]}],"description":[{"lang":"tw","x_late":"此套件可更新連接智慧陣列控制器及主機匯流排配接卡的 HP D2600 與 D2700 磁碟機機櫃韌體。此套件內含的 I/O 模組韌體新增改善功能，可修正在初版產品發行後使用與額外資格測試期間發現的問題。"},{"lang":"en","x_late":"This package updates the firmware on HP D2600 and D2700 Disk enclosures attached to Smart Array Controllers and Host Bus Adapters. I/O module firmware included in this package adds improvements and corrects issues found during use and additional qualification testing after initial product release."},{"lang":"ko","x_late":"이 패키지는 스마트 어레이 컨트롤러 및 호스트 버스 어댑터에 장착되어 있는 HP D2600 및 D2700 디스크 인클로저의 펌웨어를 업데이트합니다. 이 패키지에 포함된 I/O 모듈 펌웨어에서는 제품 출시 후 사용 또는 추가 적격 테스트 과정에서 발견된 문제를 수정하고 개선 사항을 추가하였습니다."},{"lang":"cn","x_late":"该软件包用于更新连接至智能阵列控制器和主机总线适配器的HP D2600和D2700磁盘机柜固件。此软件包中包含的 I/O 模块固件添加了改进，并纠正了首次产品发布后在使用期间及额外资格测试时发现的问题。"},{"lang":"ja","x_late":"このパッケージは、Smartアレイコントローラーおよびホストバスアダプターに接続されているHP D2600およびD2700ディスクエンクロージャーのファームウェアをアップデートします。 このパッケージに含まれるI/Oモジュールのファームウェアは、初期リリース後、実際の使用中および追加テストで見つかった問題の改善と修正を追加します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4640664","datemodified":"2015-11-30T23:28:25","file_list":["CamFlash.dll","CamFlash.dll.2.config","CAMSPR0150_6G_app_4MB_ai.pmc","cp028806.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcm90.dll","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll"],"md5sum":"dcf60f3a04f275767f9d606ac5d0f4b6","name":"cp028806.exe","release":"2016-10-07T00:00:00","revision":"1","sha1sum":"f7406fb3b516f2400dde54397a86d4066e410a8b","size":"4MB","target_guids":[],"type_of_change":"1","version":"0150"}],"id":{"product":"5f78fc3b4e0e4c3db7002c50957e782b","version":"6d71ca35ea2d43468453f871ca0717a5"},"installation":{"command":"cpqsetup.exe","command_params":"/iCAMSPR0150_6G_app_4MB_ai.pmc /v0150 /t\"D2600 SAS AJ940A\" /t\"D2700 SAS AJ941A\" /t\"260 SAS AJ940A\" /t\"270 SAS AJ941A\" /t\"D2x00 Disk Enc.\" /t\"MDS260 CAMARO\" /t\"MDS270 CAMARO\"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Firmware installation i<strong>nstructions</strong>&nbsp;for Smart Array configurations:</strong><br />\n<br />\nFirmware is embedded in the downloaded file, which is a self-extracting, executable module. Execute this module from the command line console or the Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p><strong>To use HP Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages.</li>\n\t<li>Run the launch_hpsum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Special installation instructions for single-domain environments:</strong><br />\n<br />\nIn a single domain configuration, I/O module A (top module) is connected to a SmartArray controller and I/O module B (bottom module) is unused. Even though the bottom I/O module is unused, both modules must have the same firmware version installed. Do the following to make sure that BOTH I/O modules are updated:</p>\n\n<ol>\n\t<li>Flash I/O module A of the first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After I/O module A is flashed successfully in the disk enclosures, shut down and turn off the server.</li>\n\t<li>Remove A/C power to the first and all cascaded disk enclosures.</li>\n\t<li>Label all cables connected to I/O module A of the first and all cascaded disk enclosures and then disconnect all cables from the I/O modules.</li>\n\t<li>Swap the positions of the I/O modules in the enclosure.</li>\n\t<li>Reconnect the cables to the top I/O module (it used to be the bottom I/O module) in the enclosure, using the labels to ensure that all cabling is connected properly, in the same configuration as before.</li>\n\t<li>Turn on the storage enclosures and wait for them to complete their startup routines.</li>\n\t<li>Turn on the server.</li>\n\t<li>After the server startup procedure is complete, flash the top I/O module (the new I/O module A) of first and all cascaded disk enclosures using the firmware upgrade executable.</li>\n\t<li>After the I/O module is flashed successfully in the disk enclosures, power cycle the server to resume normal operation.</li>\n</ol>\n\n<p><strong>Installation Notes and Best Practices:</strong></p>\n\n<ul>\n\t<li>Before installing new firmware, review system requirements, enhancements list, fixes list, and other information in the firmware release notes, device QuickSpecs, and updated user documentation.</li>\n\t<li>Before installing new firmware, ensure that the system is stable and is not being reconfigured or changed in any way. If changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade.</li>\n\t<li>Before installing new firmware, HP recommends creating a full backup of all data stored on the enclosure.</li>\n\t<li>When planning for a firmware update, schedule an appropriate time to perform an the update. Firmware updates must be performed during a system maintenance window, with all I/O to the system halted.</li>\n\t<li>After the installation process, verify system status in the software tools and confirm that the new firmware version is displayed as running on the enclosure.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong><strong>Smartアレイ構成のためのファームウェアのインストール手順：</strong></strong><br />\n<br /> ファームウェアはダウンロードされたファイルに含まれており、自己解凍型の実行可能モジュールです。コマンドラインコンソールかWindowsグラフィカルユーザーインターフェイスからこのモジュールを実行してください。</p>\n\n<p><strong>GUIオプション：</strong></p>\n\n<ol>\n\t<li>ダウンロードしたファームウェアパッケージを一時ディレクトリに置きます。</li>\n\t<li>Windowsエクスプローラーを使って、ダウンロードを含んでいるディレクトリに移動します。</li>\n\t<li>実行可能ファイルをダブルクリックします。</li>\n\t<li>画面上の指示に従います。</li>\n</ol>\n\n<p><strong>CLIオプション：</strong></p>\n\n<p>次のコマンドを入力して、Smartコンポーネントを実行します： CP0xxxxx.exe /s</p>\n\n<p><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant  </a></strong><strong>からHP Smart Update Managerを使用するには、以下の手順に従ってください。 </strong><strong>:</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.bat を実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>注: </strong>バンドエンクロージャーフラッシュのオプション：</p>\n\n<p><strong>パラメーター</strong>                      <strong>説明</strong><br /> -----------------------------------------------------------------------------<br /> <strong>/h,/? </strong>           コマンドラインの使用方法のヘルプを表示します(ダイアログボックス)<br /> <strong>/s  </strong>                ユーザーの操作なしでインストールします</p>\n\n<p><strong>/sを使用すると以下のコマンドが適用されます：</strong><br /> <strong>/f  </strong>               最新である場合、ダウングレードまたは再インストールできます</p>\n\n<p> </p>\n\n<p><strong>シングルドメイン環境での特別なインストール手順</strong><br />\n<br /> シングルドメインの構成では、I/OモジュールA（上側のモジュール）は、Smartアレイコントローラーに接続し、I/OモジュールB（下側のモジュール）は使用されません。たとえ下側のI/Oモジュールが使われない場合でも、両方のモジュールは同じファームウェアバージョンがインストールされていなければなりません。必ず両方のI/Oモジュールがアップデートされるように、以下を実行してください。</p>\n\n<ol>\n\t<li>実行可能なファームウェアアップグレードを使用して、最初のI/OモジュールAと全てのカスケードされたディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャーでI/OモジュールAのフラッシュが成功した後、シャットダウンしてサーバーの電源を落とします。</li>\n\t<li>最初にA/C電源を、次にカスケードされた全てのディスクエンクロージャーを取り外します。</li>\n\t<li>最初のI/OモジュールAとカスケードされた全てのディスクエンクロージャーに接続されたケーブルにラベルを記載します。そして、I/Oモジュールからケーブルを取り外します。</li>\n\t<li>エンクロージャー内のI/Oモジュールの位置を交換します。</li>\n\t<li>以前の構成と同じように、全てのケーブル接続が正しいかラベルを確認して、エンクロージャー内の上側I/Oモジュール（下側I/Oモジュールとして使われていたもの）にケーブルを再接続します。</li>\n\t<li>ストレージエンクロージャーの電源を入れて、スタートアップルーチンの完了を待ちます。</li>\n\t<li>サーバーの電源を入れます。</li>\n\t<li>サーバーのスタートアッププロシジャーが完了後、実行可能なファームウェアアップグレードを使用して最初の上側I/Oモジュール（新しいI/OモジュールA）とカスケードされた全てのディスクエンクロージャーをフラッシュしてください。</li>\n\t<li>ディスクエンクロージャー内のI/Oモジュールのフラッシュが成功した後、通常の動作に戻すため、サーバーの電源を入れ直します。</li>\n</ol>\n\n<p><strong>インストールノートおよびベストプラクティス</strong></p>\n\n<ul>\n\t<li>ファームウェアをインストールする前に、システム要件、拡張リスト、修正リストおよびファームウェアリリースノート、デバイスのQuick Specs、他のユーザードキュメントの情報を確認してください。</li>\n\t<li>新しいファームウェアをインストールする前に、システムが安定していて、再設定中または変更中ではないことを確認してください。もし何らかの変更が処理中ならば、それらを監視し、処理が完了するまで待ってからアップグレードを始めてください。</li>\n\t<li>新しいファームウェアをインストールする前に、エンクロージャー上に保存されている全てのデータのフルバックアップを作成することをおすすめします。</li>\n\t<li>ファームウェアをアップグレードする場合、アップグレードを実行する適切な時間をスケジュールします。ファームウェアのアップグレードは、システムの全てのI/Oを停止して、システムをメンテナンスする期間内に行う必要があります。</li>\n\t<li>インストールプロセス後、ソフトウェアツールのシステムステータスの確認と新しいファームウェアバージョンがエンクロージャー上で実行中と表示されることを確認してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (x64) 的 HP D2600/D2700 6Gb SAS 磁碟機櫃 ROM 更新元件"},{"lang":"en","x_late":"HP D2600/D2700 6Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ko","x_late":"Windows (x64)용 HP D2600/D2700 6Gb SAS 디스크 인클로저 ROM 플래시 구성 요소"},{"lang":"cn","x_late":"用于Windows (x64)的HP D2600/D2700 6Gb SAS磁盘机柜ROM刷新组件"},{"lang":"ja","x_late":"HP D2600/D2700 6Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D2600 SAS AJ940A","target_guid":"","type":"msa"},{"id":"D2700 SAS AJ941A","target_guid":"","type":"msa"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"core","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Core Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-05-10T07:48:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fix is added in this version:-</strong></p>\n\n<p>-Removed action over FAULT_SENSED bit due to incorrect algorithm.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"D2700","sw_key_expectedpath":"firmware:QLOGIC"},{"name":"D2600","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30116","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30052","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 10/25GbE 2P SFP28 MCX512F, HPE 10/25GbE 2P SFP28 MCX562A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム上のHPE 10GbE 2P SFP + MCX4121A、HPE 10GbE 2p SFP + MCX4621A OCP3、HPE 10/25GbE 2P SFP28 MCX512F、HPE 10/25GbE 2P SFP28 MCX562A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (P13188-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (P10112-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"12065522","datemodified":"2021-01-25T16:49:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/CP045144.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045144.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045144.scexe"],"md5sum":"a6181c1df305bd04fce42de844044a5c","name":"firmware-nic-open-mellanox-eth-mft-1.0.4-1.1.x86_64.rpm","release":"2021-01-25T16:46:26","revision":"0","sha1sum":"f7842fb44b25ccbbd87f5b22739488cd7bbee1ba","size":"11MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30116","a6b1a447-382a-5a4f-15B3-101715B30052","a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.4"}],"id":{"product":"ec5ba4f75ae340e39f8e129f646a9647","version":"be56268f4f07454c962b50dc5b184194"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Linux x86_64）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.27.4000:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.27.2008:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.29.1016:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<p><strong>New Feature and Changes in Version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Ethernet wqe_too_small Mode: A per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats:</li>\n\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused packets to drop due to header size issues and/or failing checks. This issue was caused due to a Linux issue that caused VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) might take longer than when MKEY_BY_NAME was disabled.</li>\n\t<li>In rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>An issue that caused the device to go to dead IRISC as one of the firmware semaphores could not be released when a speed change or port state change was triggered.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the eth_wqe_too_small counter to count ODP page faults.</li>\n\t<li>A low performance was observed after enabling the RoCE Accelerator capability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"lang":"ja","x_late":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"589216","datemodified":"2020-12-25T03:58:37","file_list":["cp046491.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"md5sum":"7590e41f794c14e77dc018da434fe2de","name":"cp046491.exe","release":"2021-04-23T00:00:00","revision":"1","sha1sum":"de606bebe7b094a1d54c6273838814bd87826359","size":"575KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"0471b7afab434bd587f54eef07345610","version":"47378b6d3e694a65a251bb2b4aca6ff4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-28T10:21:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed branding issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"nechesasr.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD4"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD4"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4826825","datemodified":"2020-12-13T08:58:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/CP045396.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/TA14SXn0HPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045396.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045396.scexe"],"md5sum":"d5e60551dc7b71f980db9a8797f23995","name":"firmware-hdd-8d68452816-HPD4-3.1.x86_64.rpm","release":"2020-12-13T08:46:32","revision":"0","sha1sum":"8583edcb9f56b4d63f2bed49af839ec80fb57c12","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"6f10e85c0a8e4d0f99dcb8584f535fd3","version":"a9d918d5114d49569f9ed7e81f515ebb"},"installation":{"command":"CP041672.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1188.0が含まれています。</p>\n"}],"files":[{"bytes":"3566056","datemodified":"2020-06-11T04:19:57","file_list":["/cp044544.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"8072d670a52c8573702fa8b2af21fc31","name":"cp044544.zip","release":"2020-06-11T04:19:05","revision":"0","sha1sum":"c6a321999115f6ff6f29b278cac6601a7ec4f199","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7fae0e3a1408427d859a7147aca14a11","version":"d6ee5259298e469584ecb1092196dca4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.7.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3325322","datemodified":"2021-01-28T09:43:16","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"1a1097cf7c2ed3cb4e4d0446d6e49433","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-28T09:25:19","revision":"0","sha1sum":"f14069e1d34396d2b3e1e7af17ce7073f98721ba","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"4ff3517aac1346d786660aa0bedadd20","version":"3c462edc00ed4c188e0d227f7515575e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 udpate 8 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T06:10:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>  Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n     </strong> None</p>"}],"files":[{"bytes":"4342456","datemodified":"2020-12-16T21:16:24","file_list":["cp045535.xml","cpqsetup.exe","HLEBHssseFD2.rel","payload.json","setup.dll"],"md5sum":"8da64ffea3c6838d54e6e4468e88f922","name":"cp045535.exe","release":"2020-12-16T20:35:04","revision":"0","sha1sum":"8c814894fbea4f981251aa0346da9a59667bc9b5","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"83ce77cbc6db45d29c95de38716f222e","version":"855f5f83866c4aedbd854eae9ffb65a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:44:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1548667","datemodified":"2021-01-27T06:54:31","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"db1cac87a9ff47e7154a23b2ef392bcf","name":"mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_120-OFED.5.2.1.0.4.1.sles12sp5.x86_64.rpm","release":"2021-01-27T05:10:04","revision":"0","sha1sum":"19aa92e4ac8754edec5ed1bc6998e898fb894641","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1227948","datemodified":"2021-01-27T06:46:24","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/rdma-set-sriov-vf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.2.2","./usr/share/doc/packages/libvma-9.2.2/README.txt","./usr/share/doc/packages/libvma-9.2.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.2.2/journal.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"7aad9359f4bc48a2fb7e350b33e9dc4e","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles12sp5.x86_64.rpm","release":"2021-01-27T05:10:04","revision":"0","sha1sum":"4a11d42caada361bfe9462c0f45e50c8f8e1d92d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"194ff765dcf14c3183bf0b90a60ddc0c","version":"c9200f579fe44979b83963e97032fd51"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.</p>\n\n<p>To install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles12sp5.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_120-OFED.5.2.1.0.4.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T) "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.20"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.20"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10 NVMe storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10 NVMe ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"167161","datemodified":"2018-10-11T23:56:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/CP037723.xml","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/ISS_NVMe_BP_PIC_flashV1B20_signed.hex","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-1.20-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037723.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037723.scexe"],"md5sum":"e6f0ec78d59f8c1252f66f7b4832ff1e","name":"firmware-nvmebackplane-gen10-1.20-5.1.x86_64.rpm","release":"2018-10-12T04:54:03","revision":"0","sha1sum":"e388f99664669ce44e82051d2e7b4d33493faf00","size":"163KB","target_guids":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"type_of_change":"0","version":"1.20"}],"id":{"product":"88ebeea03a744545bfbd59b724e23e90","version":"fefe02a88ece449d806f8a449d8f5a0d"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037723.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-nvmebackplane-gen10-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP037723.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-nvmebackplane-gen10-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-nvmebackplane-gen10-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10 NVMe Backplane PIC Firmware"},{"lang":"ja","x_late":"Linux用オンラインフラッシュコンポーネント - Gen10 NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"00000000-0000-0000-0000-00004e564d65","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-27T08:56:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">The following support was added in version 1.20(C). No new features were added in version 1.20(D).</p>\n\n<ul>\n\t<li style=\"margin-left: 0in; margin-right: 0in;\">Added support for the HPE ProLiant XL270d Gen10 Server</li>\n</ul>\n","latest_fixes_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Firmware Package version 1.20(D) addressed the following issue:</p>\n\n<ul>\n\t<li>When using OneView, attempts to upgrade firmware from version 1.18 to 1.20 failed.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Note: If the target device was previously updated to firmware version 1.20, it is not necessary to apply firmware update 1.20(D).</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server (private)"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server (private)"}],"sw_keys":[{"name":"NVMePIC-Gen10","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16812541","datemodified":"2020-11-03T03:52:37","file_list":["payload.json","U43_2.20_10_27_2020.signed.flash","U43_2.20_10_27_2020.xml"],"md5sum":"3ccbf6d9970c8d81ffdaa30af19fadae","name":"U43_2.20_10_27_2020.fwpkg","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"3530d8dab6a07d4d0df5a10afd05e2b6d0f8477c","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"b64e2e4187274c5798b3aa127c50ba6a","version":"dd2a039afa014db0aaba522b79ef93cb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10(U43)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含的驅動程式適用於在 Windows Server 2016 執行的 HPE Intel E1R Gigabit Ethernet NIC。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel E1R 기가비트 이더넷 NIC용 드라이버가 들어 있습니다."},{"lang":"cn","x_late":"该组件包可为在 Microsoft Windows Server 2016 下运行的 HPE Intel E1R 千兆以太网卡提供驱动程序。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1189672","datemodified":"2021-01-09T06:17:15","file_list":["cp045120.xml","cpqsetup.exe","cp_data.xml","e1r65x64.cat","e1r65x64.din","e1r65x64.inf","e1r65x64.sys","e1rmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"cbc53810a3d1e021222ca45ce5aa8459","name":"cp045120.exe","release":"2021-01-09T06:02:05","revision":"0","sha1sum":"30c611a0f33fe7c2e6038a66970319f81aa39b3b","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac"],"type_of_change":"0","version":"12.16.3.1"}],"id":{"product":"fc4022f2727541aca9a0c50b935a3b24","version":"2c39c7e85bf4437792b2074c52c6bd1e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE Intel E1R 驅動程式（適用於 Windows Server 2016）"},{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel E1R 드라이버"},{"lang":"cn","x_late":"适用于 Windows Server 2016 的 HPE Intel E1R 驱动程序"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n\n<p>This product add Wrapping and fix Support To Cometlake,and added thermal sensor support for fiber NIC.</p>\n","latest_fixes_x_late":"<p>This product correct an issue which override and copy constructor to MSIX_AFFINITY_MANAGEMENT class to eliminate KW issues with double freeing memory.<br />\nThis product correct an issue which fixed e1r compile to exclude Nahum Icelake defines.<br />\nThis product correct an issue which fixed conversion of timestamp into 64bit value.<br />\nThis product correct an issue which fix for NDIS Miniport Kernel Pointer Leakage</p>\n"},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"e1r65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB012000JWDFD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4089520","datemodified":"2020-12-16T13:34:16","file_list":["cp045531.xml","cpqsetup.exe","HLEAHssseFD2.rel","payload.json","setup.dll"],"md5sum":"7a2f03859a843d9d4a4d4d3f9ab92b94","name":"cp045531.exe","release":"2020-12-16T13:25:04","revision":"0","sha1sum":"bf9722f7bed7a2dd95117de0d9b7a98d86d24116","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"2","version":"HPD2"}],"id":{"product":"4893b899f6404bf4b119e3e3a55be5b2","version":"558d89fb5c7745e0b072533baa1b1456"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:43:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11622728","datemodified":"2021-01-27T20:13:34","file_list":["cp046684.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_2.42_01_23_2021.signed.flash"],"md5sum":"358a4c1c00f968024af5f1d7eec88736","name":"cp046684.exe","release":"2021-01-27T20:06:04","revision":"0","sha1sum":"d2d168a11e2dfe7a7bf7769fa748e5019ad35926","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"ccbfcdbdc47644e7ab18a371d4af9d7a","version":"8b00f222cb9745349d08269c71ac897c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T20:44:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD3"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP and EG001200JWJNQ&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5918794","datemodified":"2020-12-13T08:07:59","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/CP045379.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/SSKYBT512ND3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045379.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045379.scexe"],"md5sum":"0c9d6fb45551540d5654dd16d520e92e","name":"firmware-hdd-bdfb8e99d9-HPD3-3.1.x86_64.rpm","release":"2020-12-13T07:56:11","revision":"0","sha1sum":"ff27e0e073d222ff0ed21963c66e99277091d5ee","size":"5MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"73ec3bde4c824e4abd7a12e09eb4bcb4","version":"391aebf56c6b449280217cb067adb25e"},"installation":{"command":"CP041693.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP and EG001200JWJNQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:32:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4638222","datemodified":"2020-12-13T09:01:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/CP045402.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/GS865aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045402.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045402.scexe"],"md5sum":"5c4fd5195211e66b0bbf90b6683bc660","name":"firmware-hdd-5bf9355926-HPG3-6.1.x86_64.rpm","release":"2020-12-13T08:48:08","revision":"0","sha1sum":"88a296e0471756ddebd6b0f7afa94e9b04953eb9","size":"4MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"916fe10c0989454da7fed6ac8080c703","version":"8c09efb1863c40f3ae6c0bd65a8968fb"},"installation":{"command":"CP040347.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR216i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-p_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7490141","datemodified":"2021-02-26T06:54:34","file_list":["HPE_MR216i-p_Gen10P_52.16.3-3913.ilo","HPE_MR216i-p_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"6131dbe5a7a6fca8d07e048f26bda6fd","name":"HPE_MR216i-p_Gen10P_52.16.3-3913.fwpkg","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"4904a4643860b064d7e8ea0f92a3633dda4491dc","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032b"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"87a7eb56c25b4c4c98ceb5ea24664524","version":"ae89f359185b4983a222e880564755e2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR216i-p Gen10 Plus Tri Mode Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T07:28:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"032B1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB004000GWKGV drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB004000GWKGVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18613785","datemodified":"2021-01-27T22:23:49","file_list":["/CP045631_BUILD_3.data","/CP045631.vmexe","/CP045631.vmexe64","/CP045631.vmfile","/CP045631_VMw.zip","/CP045631.xml","/payload.json","/CP045631_VMw.zip/index.xml","/CP045631_VMw.zip/vendor-index.xml","/CP045631_VMw.zip/metadata.zip","/CP045631_VMw.zip/vib20/CP045631/HPE_bootbank_CP045631_HPG1.3-7.0.0.15843807.vib","/CP045631_VMw.zip/metadata.zip/vendor-index.xml","/CP045631_VMw.zip/metadata.zip/vmware.xml","/CP045631_VMw.zip/metadata.zip/vibs/CP045631--4024702726501127606.xml","/CP045631_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045631_HPG1.3-7.0.0.15843807.xml"],"md5sum":"08fc0f39e5d689b4f9f12c4d2b3156a9","name":"CP045631.zip","release":"2021-01-27T22:21:05","revision":"0","sha1sum":"e87c66778c7c33c558e496c1ef9a2187d34105cf","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045631","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"cc96bd351eff4426bf37f3da741a7623","version":"7f784a4a975146e49b691647878f6949"},"installation":{"command":"CP041493.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:34:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25192","datemodified":"2021-02-11T01:05:26","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/99","./usr/lib/.build-id/99/2d3ab5d9085915f48edcbc531702436c72fb53","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"22b00b36be7f99a9a827c2f382c7acfc","name":"libbnxt_re-218.0.7.0-rhel8u2.x86_64.rpm","release":"2021-02-11T01:02:04","revision":"0","sha1sum":"be366120973b74019a8d48f7255610407840bb13","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"67c1e7cc9a5f4a98b6e37ff05556aec1","version":"228b5255801449f6a047211f91a3c05e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 2."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10+ controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2916728","datemodified":"2021-02-26T10:43:59","file_list":["cp045859.xml","cpqsetup.exe","install.xml","multisetup.dll","StorCLI.msi"],"md5sum":"2a4bf1b69511b306a011918f32c873bc","name":"cp045859.exe","release":"2021-02-26T10:41:07","revision":"0","sha1sum":"516e823c79a3bfe3c4a15ac30d5e3014ca0a69d7","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"type_of_change":"0","version":"7.1616.0.0"}],"id":{"product":"a215c8b0f11b453cbd6a752733ae590e","version":"324f5f9946bd49479a1bb405eea898c0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n\n<p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p>\n\n<p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-08T19:34:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Supports maintaining&nbsp;and configuration of Gen10+ MegaRAID Controllers: MR416i-a, MR416i-p, MR216i-a, MR216i-p</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"storcli64.exe","sw_key_expectedpath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWFVB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWFVB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16150286","datemodified":"2021-01-27T08:19:16","file_list":["/CP045604_BUILD_4.data","/CP045604.vmexe","/CP045604.vmexe64","/CP045604.vmfile","/CP045604_VMw.zip","/CP045604.xml","/payload.json","/CP045604_VMw.zip/index.xml","/CP045604_VMw.zip/vendor-index.xml","/CP045604_VMw.zip/metadata.zip","/CP045604_VMw.zip/vib20/CP045604/HPE_bootbank_CP045604_HPD2.4-7.0.0.15843807.vib","/CP045604_VMw.zip/metadata.zip/vendor-index.xml","/CP045604_VMw.zip/metadata.zip/vmware.xml","/CP045604_VMw.zip/metadata.zip/vibs/CP045604-1506884356224188057.xml","/CP045604_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045604_HPD2.4-7.0.0.15843807.xml"],"md5sum":"e05981544e665dc791cac206310cecf5","name":"CP045604.zip","release":"2021-01-27T08:16:25","revision":"0","sha1sum":"f581ebf27c734a5845902cce636f891504e6ab71","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045604","version":"HPD2.4-7.0.0.15843807"}]}],"id":{"product":"911c76d50a064e62be53550825c8db4d","version":"29efe2217ec34feaa600e7af0d932456"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWFVBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:10:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MM1000GFJTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します： MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3540768","datemodified":"2020-12-16T15:37:50","file_list":["cp044278.xml","cpqsetup.exe","payload.json","SAVGNTG5.rel","setup.dll"],"md5sum":"0936317dc0e55b27082bb164002d944e","name":"cp044278.exe","release":"2020-12-16T15:26:05","revision":"0","sha1sum":"d1dea31899a59f0f2492ecf3321e8ed2d8bc8cef","size":"3MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"4106b2f5d7c1411c95e94d52dff63df7","version":"a597c6f939394ac9b3cc5e8ed515d49b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-30T07:01:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.44_10_29_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.44 (10/29/2020)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17564885","datemodified":"2020-11-06T02:50:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/A40_2.44_10_29_2020.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/CP046091.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.44_2020_10_29-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046091.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046091.scexe"],"md5sum":"778374407d03e2d9e21be401dc385ea4","name":"firmware-system-a40-2.44_2020_10_29-1.1.x86_64.rpm","release":"2020-11-06T02:42:05","revision":"0","sha1sum":"226d72d88afcc078e278e27b33520e408e034804","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"2.44_10-29-2020"}],"id":{"product":"d313ecbde1f54151bf42ad357e6b94ad","version":"f19c9745130b4cc1aa3468994cb0ae2b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL385 Gen10 (A40) サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:52:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices. &nbsp;This option would only be used for PCIe Adapters that support his level of bifurcation.&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where the system may hang during boot up after a warm reset from the OS.</p>\n\n<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p>\n\n<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含的套件 QLogic 光纖通道主機匯流排配接卡的 Windows 64 位元作業系統上提供對 Smart SAN 的支援。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Windows 64 bit operating systems."},{"lang":"ko","x_late":"이 패키지에는 Windows 64 비트 운영 체제에서 QLogic 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Windows 64 位操作系统上的 QLogic 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、Windows 64ビット オペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1608088","datemodified":"2019-10-07T05:57:06","file_list":["cp039719.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"md5sum":"6ed5d798449c193b9cea373f8bb7099f","name":"cp039719.exe","release":"2019-11-05T00:00:00","revision":"1","sha1sum":"3706c419a7a9607766f7e53cf253197fdba58af0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"7eb6e3adc2094748b6a18ae2e5daf1e0","version":"44318fd5ae674b269a7ca5f826fc3af5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>For detailed information about configurable components, see the <em>HP Smart Update Manager User Guide </em>at <a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>.</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>これは構成可能コンポーネントです。  Smart SAN 機能を有効/無効にするための構成ファイルが必要です。  構成を実行できない場合、Smart SANの現状が記載され、実行が完了します。  それ以上の処置は不要です。</p>\n\n<p>構成コンポーネントについての詳細は、<em>http://www.hpe.com/support/HP_SUM_UG_ja</em>で提供されている<a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">HP Smart Update Managerユーザーガイド</a>を参照してください。</p>\n\n<p><strong>ProLiant の HPE サービスパックの外部コンポーネントの実行</strong>:</p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>インストールボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN Enablement Kit for Microsoft Windows Server 64 bit operating systems"},{"lang":"ja","x_late":"HPE QLogic Smart SANイネーブルメントキットfor Microsoft Windows Server 64ビットオペレーティングシステム"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"338E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c338e","type":"pci","ven":"1077"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-23T09:58:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLSMARTSANVer.exe","sw_key_expectedpath":"%SystemDrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"287232","datemodified":"2021-01-09T01:23:02","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"6c400329eb6ea620359d93d15da2d406","name":"kmod-hp-i40e-2.13.10-1.rhel8u3.x86_64.rpm","release":"2021-01-09T01:11:05","revision":"0","sha1sum":"f2c4c9278f2318681bcb6375d1816ff236aa9e78","size":"280KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.13.10-1"},{"bytes":"287143","datemodified":"2021-01-09T01:18:43","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"7ef30d15581fca6b80385ce5249f41dd","name":"kmod-hp-i40e-2.13.10-1.rhel8u2.x86_64.rpm","release":"2021-01-09T01:11:05","revision":"0","sha1sum":"d679ce6eeba330fbe266fc15be31f1cc165dd334","size":"280KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.13.10-1"}],"id":{"product":"79178f63311141b49420306fd1de47d3","version":"dd47c8e9f4644fc2bd05c2f4b0c1cd29"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS.</li>\n\t<li>This product corrects an issue which querying DCB configuration data failed on Intel Carslville controller if driver probe or set &nbsp;at 2.5/5G speed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product supports new feature called software DCB(Data Center Bridging) which allows using DCB without firmware LLDP(Link Layer Discovery Protocol) agent being turned on.</li>\n\t<li>This product supports new feature which allows user to specify VLAN(Virtual Local Area Network) field and add it to flow director via ethtool</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where server hungs after loading XDP(eXpress Data Path) program in case of LLDP(Link Layer Discovery Protocol) agent disabled&nbsp;</li>\n\t<li>This product addresses an issue where it is not possible to change MAC(Media Access Control) address on VF(Virtual Function) from VM(Virtual Machine) when VF is in trusted mode</li>\n\t<li>This product addresses an issue where it cannot create VF(Virtual Function) VLAN(Virtual Local Area Network) interface inside a namespace&nbsp;</li>\n\t<li>This product addresses an issue where system crash during removing driver when VSI(VIrtual Station Interface) is in reset recovery mode</li>\n\t<li>This product addresses an issue where VF(Virtual Function) receives unicast packets from other VF</li>\n\t<li>This product addresses an issue where using Intel nvmupdate utility never ending update</li>\n\t<li>Thips product addresses an issue where kernel crash in vf driver(iavf) reset when pf driver(i40e) is removing</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"838024","datemodified":"2020-12-02T17:17:13","file_list":["cp045180.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"030b11b1e5b8b299c9b7557c00cffce3","name":"cp045180.exe","release":"2020-12-02T17:03:19","revision":"0","sha1sum":"c65ccb6aa03228365c3b5e6fdb6616759aa67c20","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"266dae77506e4f72bfe8d5ce5b7da6ff","version":"f1feb21534d940fbae7a5300f1794584"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library vxnmsg.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4070560","datemodified":"2020-12-16T21:57:41","file_list":["cp045534.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"md5sum":"f97b0155d6c931b4e175032225c3ae82","name":"cp045534.exe","release":"2020-12-16T21:10:09","revision":"0","sha1sum":"9ab816d1da55bbbb145005b3fe0112984f16e522","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"63976963938d4f79be04f7b652abb966","version":"92a9354255ef43c9839e49db669af5e2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:44:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Windows Server 2012, Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE QLogic FastLinQ 10/25/50 GbEサーバーアダプタードライバー for Windows Server 2012、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>Windows qevbd Driver, 8.55.5.0</li>\n\t<li>Windows&nbsp;VBD Client,&nbsp;8.55.3.0</li>\n\t<li>Windows FCoE Offload Driver , 8.55.2.0</li>\n\t<li>Windows&nbsp;iSCSI Offload Driver,&nbsp;8.53.51.0</li>\n\t<li>Windows&nbsp;FCoE Crash-dump Driver,&nbsp;8.42.2.0</li>\n\t<li>Windows&nbsp;iSCSI Crash-dump Driver,&nbsp;8.42.1.0</li>\n</ul>\n"}],"files":[{"bytes":"3434232","datemodified":"2021-01-08T08:41:15","file_list":["cp044990.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"md5sum":"44e9ac741a0ca356e9c6b6a55d5c194e","name":"cp044990.exe","release":"2021-01-08T08:20:09","revision":"0","sha1sum":"2f69b3ea3fb9b5414603fb57179687f9daf3ca9e","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"0","version":"8.55.5.0"}],"id":{"product":"ff242e39c275472185612592300114ce","version":"7f828e99d4614ad99fde22134e410c0c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"Windows Server x64 Edition用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bf","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002be","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002c0","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021f","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021f","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021a","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021b","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021a","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021b","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021a","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixes the Virtual Function (VF) sleep duration on the channel while it waits for Physical Function(PF) response.</li>\n\t<li>This product correct an issue which System crashed when Single Root I/O Virtualization(SR-IOV) enabled on few partitions and disabled on few partitions using OneView.</li>\n\t<li>This product correct an issue which operating system boot failure after update Firmware to 08.50.27.</li>\n\t<li>This product correct an issue which System crashed is seen while upgrading drivers on enabled Network Partitioning (NPAR) and Single Root I/O Virtualization(SR-IOV) with enterprise data Center mode.&nbsp;</li>\n\t<li>This product correct an issue which Virtual Machines (VMs) crash randomly upon advanced property disable/enable with Max virtual functions (VFs) enumerated on all Physical Functions(PFs).</li>\n\t<li>This product correct an issue which System crashed seen while disabling Network Driver Interface Specification (NDIS) driver while running &nbsp;RoCEv2 IPv6 traffic on Management OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an Wake-on-LAN (WoL) function unavailable.</li>\n\t<li>This product correct high CPU usage with Virtual Machine Multiple Queues (VMMQ).</li>\n\t<li>This product addresses a BSOD seen when using the netsh utility to configure global RSS.</li>\n\t<li>This product correct an issue which fixes BSOD in case of NicSwitch and send NBL has vport id which exceeds max vports capability.</li>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen where an SR-IOV virtual function to assign while installing driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qevbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15707122","datemodified":"2020-06-15T19:37:46","file_list":["/CP043753_BUILD_3.data","/CP043753.vmexe","/CP043753.vmexe64","/CP043753.vmfile","/CP043753_VMw.zip","/CP043753.xml","/payload.json","/CP043753_VMw.zip/index.xml","/CP043753_VMw.zip/vendor-index.xml","/CP043753_VMw.zip/metadata.zip","/CP043753_VMw.zip/vib20/CP043753/HPE_bootbank_CP043753_HPK4.3-7.0.0.15843807.vib","/CP043753_VMw.zip/metadata.zip/vendor-index.xml","/CP043753_VMw.zip/metadata.zip/vmware.xml","/CP043753_VMw.zip/metadata.zip/vibs/CP043753--8107105516848386582.xml","/CP043753_VMw.zip/metadata.zip/bulletins/Smart-Component-CP043753_HPK4.3-7.0.0.15843807.xml"],"md5sum":"cea2056041a76e2e769c6d0dc11e1c16","name":"CP043753.zip","release":"2020-06-15T19:35:04","revision":"0","sha1sum":"188b17ef89b38a0bc5eb7f72a95bda370b909f1a","size":"14MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP043753","version":"HPK4.3-7.0.0.15843807"}]}],"id":{"product":"199eba867d0c4e0892143a3378628d99","version":"d5a07e119d6b45e5a0c9abffae50f4e0"},"installation":{"command":"CP040195.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-07T13:17:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive model: MB8000JFECQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17700000","datemodified":"2021-01-28T16:28:45","file_list":["/CP045668_BUILD_3.data","/CP045668.vmexe","/CP045668.vmexe64","/CP045668.vmfile","/CP045668_VMw.zip","/CP045668.xml","/payload.json","/CP045668_VMw.zip/index.xml","/CP045668_VMw.zip/vendor-index.xml","/CP045668_VMw.zip/metadata.zip","/CP045668_VMw.zip/vib20/CP045668/HPE_bootbank_CP045668_HPD7.3-7.0.0.15843807.vib","/CP045668_VMw.zip/metadata.zip/vendor-index.xml","/CP045668_VMw.zip/metadata.zip/vmware.xml","/CP045668_VMw.zip/metadata.zip/vibs/CP045668--3516931625537107091.xml","/CP045668_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045668_HPD7.3-7.0.0.15843807.xml"],"md5sum":"78a56311ef41e3c6e5a5db8c9314089f","name":"CP045668.zip","release":"2021-01-28T16:26:04","revision":"0","sha1sum":"0bf6bdd8270d89f9c74db64923fc151268198546","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP045668","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"b02d63095f7c44f5ba3d7deb6bb4021a","version":"6c0173c9b8e447549f9a03f6b15b586f"},"installation":{"command":"CP040532.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:08:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GVYZBおよびMB4000GVYZAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5351490","datemodified":"2020-12-13T13:59:13","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/CP045442.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/SMBPETG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045442.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045442.scexe"],"md5sum":"1805963b8cc84060bf4d6a7c72e9de9c","name":"firmware-hdd-0a7d4aa47f-HPG4-5.1.x86_64.rpm","release":"2020-12-13T13:48:05","revision":"0","sha1sum":"356c3050feff304c55755b8d3d848f7c96c3b779","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d7e21057ac6640f0b343d9d0d83a30a1","version":"b042f267b9b1478b9cf8f4c8cb9a10be"},"installation":{"command":"CP040339.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYZB and MB4000GVYZA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6110017","datemodified":"2020-11-05T04:15:33","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/CP046138.xml","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/P99_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p99-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046138.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046138.scexe"],"md5sum":"31c06c690d02decdfa8de0bb5093ce6e","name":"firmware-system-p99-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-05T03:58:06","revision":"0","sha1sum":"d8343ac2bc91c8d94a4f0f14df46751b7948412f","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"b0d92753c2304b2890afe0bb312c776b","version":"aea77a32edbd4da78d457dfbe0c199d3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen9 (P99) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant ML110 Gen9(P99)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-23T09:13:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"P99","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6172384","datemodified":"2020-12-17T19:57:47","file_list":["/CP046428.vmexe","/CP046428.vmfile","/CP046428.xml","/README.txt"],"md5sum":"3daa6f94288f802dfd9ec274fec60976","name":"CP046428.zip","release":"2020-12-18T01:55:09","revision":"0","sha1sum":"fb41b2d9c5bec3d93171a5be62c8fb87ccd90bc3","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020","vib_list":[]}],"id":{"product":"4c879b2de58c433090e3e0a088f41fb0","version":"24a0de66235147298195d5e4250c46fa"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:10:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.20 (10/27/2020)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8454995","datemodified":"2020-11-02T15:12:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/CP045741.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/U48_2.20_10_27_2020.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.20_2020_10_27-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045741.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045741.scexe"],"md5sum":"a3d67e0844ef04a0346ba142667b241d","name":"firmware-system-u48-2.20_2020_10_27-1.1.x86_64.rpm","release":"2020-11-02T15:06:05","revision":"0","sha1sum":"da4c9bdc0c74a1ac2ec56465ebe8494cfb2efa98","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"0","version":"2.20_10-27-2020"}],"id":{"product":"2bd1c3f2d559498081c13ef5a6c74bb4","version":"1f30a28605ea456fb738777ccafb03c4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T03:37:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode for Intel Pentium processors which provides mitigations for security vulnerabilities documented as CVE-2020-0543 as well as CVE-2020-0548 and CVE-2020-0549. These security vulnerabilities are documented in Intel Security Advisories INTEL-SA-00320 and INTEL-SA-00329. These issues are not unique to HPE servers. This update does not impact systems using Intel Xeon based processors.</p>\n\n<p>Addressed an issue where the system would become unresponsive with a Red Screen or hang when booting to FreeBSD R12.1 from a USB device when in Legacy Boot Mode. This issue did not impact systems configured for UEFI Boot Mode or when booting from other types of media.</p>\n\n<p>Addressed an issue where a dual port networking device may show up in the System Configuration Utilities with two Port 1 names instead of properly being represented as Port 1 and Port 2. This did not impact any functionality to the device.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.</p>\n\n<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n\n<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.</p>\n\n<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK007680GWSXNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3124768","datemodified":"2020-12-16T12:14:26","file_list":["cp045573.xml","cpqsetup.exe","M52008G2.rel","payload.json","setup.dll"],"md5sum":"cafb801594b32f478b589929c20fa3db","name":"cp045573.exe","release":"2020-12-16T12:05:09","revision":"0","sha1sum":"c85e1bbd4deb3d5b8f13a6571e44e56c99280511","size":"2MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"32232f7880984b91885a4743fd2f886d","version":"bd4ab65f4e8748828973811c632e4dcd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:59:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SPSGen10_04.01.04.423.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.423"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8410701","datemodified":"2020-10-30T08:15:46","file_list":["payload.json","SPSGen10_04.01.04.423.signed.bin","SPSGen10_04.01.04.423.xml"],"md5sum":"e98ecc9d2c0a93b57ddd59b2ec428cf4","name":"SPSGen10_04.01.04.423.fwpkg","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"11ef10863ee9ed0b8ca5a82cbaed6cc17d4ca0f1","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"1","version":"04.01.04.423"}],"id":{"product":"c4ff2ade728c42bfb931931df173daf9","version":"51e015bbe6d84252a5b8affebd467024"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T03:52:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1943232","datemodified":"2021-02-09T07:57:23","file_list":["cp045131.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"fd56012afeafa83fc74d2f135ab13fd9","name":"cp045131.exe","release":"2021-02-09T07:43:04","revision":"0","sha1sum":"6b1951edccc1a5af97cc7a29f208f9b92ab4ff10","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"ed4e13cf761c496aa2355b8c9f267dd3","version":"8406d28aa2cf442aa067a3754e08c1e2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2016"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ol>\n\t<li>The number of VMs is limited to 124 VMs with VMQ(Virtual Machine Queue) mode.</li>\n\t<li>The driver supports up to 200 vPorts in ConnectX-4 Lx and 254 vPorts in ConnectX-5 with SRIOV(Single Root I/O Virtualization).</li>\n</ol>\n","latest_fixes_x_late":"<ol>\n\t<li>This product correct an issue which caused memory corruption in case the OS provided continues memory across multiple pages that did not start with offset zero on aligned memory address.</li>\n\t<li>This product correct an issue that prevented the device from being updated with the new driver because the driver was already in the driver store.</li>\n\t<li>This product correct an issue which occasionally prevented the VF counters from being displayed correctly in perfmon.</li>\n\t<li>This product correct an issue which caused the driver to report zero link speeds supported when working with firmware older than 1x.18.0240.</li>\n\t<li>This product correct an issue which fixed a memory leak issue in error flow during driver initialization.</li>\n</ol>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GVYZBおよびMB4000GVYZAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3513352","datemodified":"2020-12-16T17:22:45","file_list":["cp045553.xml","cpqsetup.exe","payload.json","setup.dll","SMBPETG4.rel"],"md5sum":"8371b990ecbaac2e576e383f1ef6366f","name":"cp045553.exe","release":"2020-12-16T17:11:07","revision":"0","sha1sum":"7fd16313b325aadde79195264855107acff13a2c","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"91ee236bfbbc43019f9a1a0183e7fcbd","version":"b57ca48a980f45e58d9055497c3a695d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYZB and MB4000GVYZA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:51:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the HPE BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class バーチャルコネクトモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class バーチャルコネクトモジュールの管理機能を提供します。このコンポーネントとそのファームウェアは、次のシナリオで使用できます：1) コンポーネントをHPE BladeSystemオンラインファームウェアバンドルにあるSmart Update Managerとともに使用することで、ファームウェアをHPE BladeSystem c-Classバーチャルコネクトモジュールに実装できる、および2) コンポーネントから展開したファームウェアを、HPE BladeSystem c-Classバーチャルコネクトモジュール対応のバーチャルコネクトサポートユーティリティを使用して実装できる。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257797526","datemodified":"2020-07-20T02:59:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/CP043331.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/HpsumCli","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/PackageDesc.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/cp_data.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/vcfwall485.bin","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043331.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043331.scexe"],"md5sum":"a1b889c932cd07ff8ea69c6f1d27819a","name":"firmware-vceth-4.85-1.1.x86_64.rpm","release":"2020-07-20T02:42:05","revision":"0","sha1sum":"b846ba26deeafa3dfcc8c7ed593a26f18efa1cba","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"f94dec5c06294dd898433cd8abf10b3a","version":"509893f2521f4f4595773fa96f988527"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85,&nbsp;HPE VC 8Gb 24-Port FC version 4.20, HPE VC 16Gb 24-Port FC version 4.20, and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 then upgrade from VC 4.50&nbsp;to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Linux)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition Component for Linux"},{"lang":"ko","x_late":"Linux용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Linux 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8 Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"466482-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.08-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.08"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"升级HPE ProLiant Gen9扩展卡上机柜固件的在线智能组件"},{"lang":"tw","x_late":"可升級 HPE ProLiant Gen9 擴充卡上機櫃韌體的線上智慧型元件"},{"lang":"ko","x_late":"HPE Proliant Gen9 Expander에서 인클로저 펌웨어를 업그레이드하는 온라인 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダーのエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.08<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;4.22<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.22<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;Added support for UBM backplanes</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"30303181","datemodified":"2021-01-28T16:06:55","file_list":["/CP044962_BUILD_18.data","/CP044962.vmexe","/CP044962.vmexe64","/CP044962.vmfile","/CP044962_VMw.zip","/CP044962.xml","/payload.json","/CP044962_VMw.zip/index.xml","/CP044962_VMw.zip/vendor-index.xml","/CP044962_VMw.zip/metadata.zip","/CP044962_VMw.zip/vib20/CP044962/HPE_bootbank_CP044962_5.08.18-7.0.0.15843807.vib","/CP044962_VMw.zip/metadata.zip/vendor-index.xml","/CP044962_VMw.zip/metadata.zip/vmware.xml","/CP044962_VMw.zip/metadata.zip/vibs/CP044962-3419783707285224984.xml","/CP044962_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044962_5.08.18-7.0.0.15843807.xml"],"md5sum":"8e9e7584c76f60ab6662dffe2ff163a3","name":"CP044962.zip","release":"2021-01-28T15:50:08","revision":"0","sha1sum":"75c9a4163e045f7a6fca9414cdebb9681cc2c16a","size":"28MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.08","vib_list":[{"name":"CP044962","version":"5.08.18-7.0.0.15843807"}]}],"id":{"product":"1655bc494b334729864d929c38544849","version":"abbac2961eef4e63ba2ca4e302a0e772"},"installation":{"command":"CP044962.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp; &nbsp; &nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HP Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T15:31:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Gen10 plus UBM type 1/2/3 backplanes</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Smart Carrier Authentication Failure issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2012 R2で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1441448","datemodified":"2021-01-09T08:12:06","file_list":["cp045116.xml","cpqsetup.exe","cp_data.xml","iavf64.cat","iavf64.din","iavf64.inf","iavf64.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"d22e873e3c75edf64f5d5b9ec1e5341b","name":"cp045116.exe","release":"2021-01-09T07:52:05","revision":"0","sha1sum":"546a0f1b9244e37d86d0cde1b9dae99d1e29a457","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec940399f7"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"9aed1e81a6884625ab102862e1a82c88","version":"7275b324c5d544ccaa6705c2e4e81405"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"iavf64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"ac963eeb-ed78-4f36-8cc1-29d85f34a0ac","Devices":{"Device":[{"DeviceName":"Firmware for HPE 16GB NVDIMM DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp032704.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-80ad-80ad80ad80ad","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This Windows component provides firmware upgrade for HPE 16GB NVDIMM-N DDR4-2666 Modules."},{"lang":"ja","x_late":"このWindowsコンポーネントは、HPE 16GB NVDIMM-N DDR4-2666モジュール用のファームウェアアップデートを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Support list :</p>\n\n<p>Windows:</p>\n\n<ul>\n\t<li>Windows 2019</li>\n\t<li>Windows 2016</li>\n\t<li>Windows 2012 R2</li>\n</ul>\n"}],"files":[{"bytes":"773856","datemodified":"2019-01-08T10:22:29","file_list":["cp032704.compsig","cp032704.zip","cp037531.xml","cpqsetup.exe","payload.json","SecureFlash64.dll"],"md5sum":"7333f804c260e2086d84eb2b5cfcf9ce","name":"cp037531.exe","release":"2019-01-08T16:21:04","revision":"0","sha1sum":"be36af2a699ea1d6185522a34aa1204468bb4f00","size":"755KB","target_guids":["805dd01c-eb5a-1e76-80ad-80ad80ad80ad"],"type_of_change":"1","version":"1.04"}],"id":{"product":"f164fee24b024bb9b6d0636563b8a349","version":"d29306fad0424a23825077884a917618"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant&nbsp;</a><strong>:</strong></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.bat スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - 16GB NVDIMM-N DDR4-2666"},{"lang":"ja","x_late":"Windows x64用オンラインフラッシュコンポーネント - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-05T10:16:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>Initial relaese.</p>\n"},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>Initial relaese.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes.\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3943620","datemodified":"2021-01-23T06:34:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/CP042622.xml","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/UBM3_V1.20.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-b249e2e715-1.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP042622.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP042622.scexe"],"md5sum":"c2843a62870a48a7be715119480c8530","name":"firmware-b249e2e715-1.20-1.1.x86_64.rpm","release":"2021-01-23T06:18:08","revision":"0","sha1sum":"80735b88214784e71288ba16ecabb12c893eeaf0","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.20"}],"id":{"product":"52abbcdaa353433f863db3360468056d","version":"17f689638fe444c59a3602fa72c1a870"},"installation":{"command":"CP042622.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP042622.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-b249e2e715-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP042622.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-b249e2e715-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-b249e2e715-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-b249e2e715-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM3 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-01-06T15:32:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Windowsオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート548SFP+アダプター（P11338-B21）</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"14080384","datemodified":"2021-01-19T09:07:39","file_list":["cp045200.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"86e9d429b2902fd29daa4e275015fffb","name":"cp045200.exe","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"5827860a2f94166482157f9c0a3d85ada868f24d","size":"13MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.0.4"}],"id":{"product":"17666522baed46e695f28d4315d6fdb8","version":"20e1050cec0a4d948f4b6226c1140582"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n [インストール]ボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T20:24:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.28.1002:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.28.1002:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5480347","datemodified":"2020-12-13T16:14:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/CP045856.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/SCIMARRNNTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045856.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045856.scexe"],"md5sum":"4c77d3096f2d57fb03fbf2b5049c14d4","name":"firmware-hdd-12304c1aca-HPG3-2.1.x86_64.rpm","release":"2020-12-13T16:03:04","revision":"0","sha1sum":"5ae9d24e883cf3efc8cb9b7ba513c1c033ac44fc","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"205e86b4ae1e4a28ae1e3cf39faf17ba","version":"f95e2191a7144759a7d00f4e5befb132"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T18:53:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD2"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD2"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16080029","datemodified":"2021-01-27T09:50:00","file_list":["/CP045605_BUILD_3.data","/CP045605.vmexe","/CP045605.vmexe64","/CP045605.vmfile","/CP045605_VMw.zip","/CP045605.xml","/payload.json","/CP045605_VMw.zip/index.xml","/CP045605_VMw.zip/vendor-index.xml","/CP045605_VMw.zip/metadata.zip","/CP045605_VMw.zip/vib20/CP045605/HPE_bootbank_CP045605_HPD2.3-7.0.0.15843807.vib","/CP045605_VMw.zip/metadata.zip/vendor-index.xml","/CP045605_VMw.zip/metadata.zip/vmware.xml","/CP045605_VMw.zip/metadata.zip/vibs/CP045605-737062881351837761.xml","/CP045605_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045605_HPD2.3-7.0.0.15843807.xml"],"md5sum":"3b0ae25f100cc95bf61e1e895e9fa51c","name":"CP045605.zip","release":"2021-01-27T09:47:05","revision":"0","sha1sum":"4ab00e263cf3ecad8ab99af4c0392ad9decdefca","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045605","version":"HPD2.3-7.0.0.15843807"}]}],"id":{"product":"b6cb1e645c374b3e92e6a0688121990e","version":"f3de02ce9a154305af6bbc66d8075621"},"installation":{"command":"CP041563.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:11:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWFVC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4861627","datemodified":"2020-12-13T08:10:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/CP045380.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/T14SEhD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045380.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045380.scexe"],"md5sum":"088767bd2794445625d0ef81cabf36c4","name":"firmware-hdd-693b9a2853-HPD3-6.1.x86_64.rpm","release":"2020-12-13T07:57:05","revision":"0","sha1sum":"1a2b56163b514b18fee35a3f1b2beab05759ab96","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"4dae182fcdec4e4aa31d1ea079120a60","version":"a4fbf699fa7f4607b2624c9a764f2977"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:33:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8763274","datemodified":"2021-03-16T11:39:01","file_list":["/CP047170.vmexe","/CP047170.vmexe64","/CP047170.vmfile","/CP047170.xml","/README.txt"],"md5sum":"8fe6f8cd276c42438079fbda5fab61e9","name":"CP047170.zip","release":"2021-03-16T16:36:05","revision":"0","sha1sum":"d4d7cbd84448b590df27c423772c7c322f69f1f5","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"4619ed3e4942429da3e6c3f145126229","version":"526eaea248ab401fbb3c485c35d05d49"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T16:10:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Blade Intel NIC firmware running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade Intel NICファームウェアをオンラインでアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"5870040","datemodified":"2021-03-31T19:58:22","file_list":["BNICOFUT.pdf","cp045079.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_560FLB_G33590-000_2.45_800008F0.txt","FW/HPE_560M_G43498-00X_2.18_8000083D.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/BNICOFUT_JA.pdf","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"62ae9d6ac35016b1ff144bc91da4dd64","name":"cp045079.exe","release":"2021-03-31T19:50:04","revision":"0","sha1sum":"a57b66835d0787361e0be5ffe639a06a306e07f9","size":"5MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.0.2.3"}],"id":{"product":"5676950ebe02418986b260051b7d33cb","version":"3209a2c45aba4284802eeb7340d5c470"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When updating&nbsp;firmware, refer to the Revision History and update&nbsp;to the next version as stepping up or down the ladder until the version needed is reached. For more information about downgrade limitations, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきながら、次のバージョンにアップデートします。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_usを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where the &quot;Firmware Image Properties,&quot;&nbsp;&quot;Device Level Configuration,&quot;&nbsp;and &quot;Link Speed Status&quot; options in NIC HII menu disappear when F7 is pressed.</p>\n"},{"curr_enhancements_x_late":"<p>This firmware is updated to maintain compatibility with the updated Windows ixn drivers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596371","datemodified":"2021-01-28T11:55:29","file_list":["payload.json","U41_2.42_01_23_2021.signed.flash","U41_2.42_01_23_2021.xml"],"md5sum":"6c1268e62fab92e5edcdb5f592ac5431","name":"U41_2.42_01_23_2021.fwpkg","release":"2021-01-28T11:51:05","revision":"0","sha1sum":"08c0a8cd8611181f537fc5abceac7ca077289c1a","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"2b44e5307a9948769c51d6ac1f276915","version":"fb408360ab094552956461a9b475316d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:17:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18347926","datemodified":"2021-01-28T07:22:49","file_list":["/CP045638_BUILD_8.data","/CP045638.vmexe","/CP045638.vmexe64","/CP045638.vmfile","/CP045638_VMw.zip","/CP045638.xml","/payload.json","/CP045638_VMw.zip/index.xml","/CP045638_VMw.zip/vendor-index.xml","/CP045638_VMw.zip/metadata.zip","/CP045638_VMw.zip/vib20/CP045638/HPE_bootbank_CP045638_HPD1.8-7.0.0.15843807.vib","/CP045638_VMw.zip/metadata.zip/vendor-index.xml","/CP045638_VMw.zip/metadata.zip/vmware.xml","/CP045638_VMw.zip/metadata.zip/vibs/CP045638--8885187570885759711.xml","/CP045638_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045638_HPD1.8-7.0.0.15843807.xml"],"md5sum":"2963c5084577a654a8da88d1c0ed3814","name":"CP045638.zip","release":"2021-01-28T07:20:04","revision":"0","sha1sum":"e3008b7fbfc735558dd5dd26c521327d92bec8f3","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP045638","version":"HPD1.8-7.0.0.15843807"}]}],"id":{"product":"a9e8e46bd6de460ea736a9be4499f26a","version":"2e170510af27472e84249a4614f89228"},"installation":{"command":"CP041478.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:40:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP230i, P430, P431, P731m, P830i, およびP830のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;4.54(B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;4.10<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6205987","datemodified":"2019-08-08T19:27:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/CP039413.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/firmware_signed.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-112204add8-5.02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039413.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039413.scexe"],"md5sum":"56683b9fa47d99deadc41120db13cee2","name":"firmware-smartarray-112204add8-5.02-1.1.x86_64.rpm","release":"2019-08-08T19:17:03","revision":"0","sha1sum":"a7f738ad396836db2c8e27d2efc86a0993472f3b","size":"5MB","target_guids":[],"type_of_change":"1","version":"5.02"}],"id":{"product":"453b4ea1f87f45c98bbb1d1a44fa8e02","version":"330456640bee4a069f7317cab0d05064"},"installation":{"command":"CP039413.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP039413.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;hp-firmware-smartarray-112204add8-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:&nbsp;</li>\n</ul>\n\n<p style=\"margin-left:40px\"># ./ CP039413.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">#&nbsp;<em>./hpsetup</em> in the &#39;/usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-112204add8-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/hp-firmware-smartarray-112204add8-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;hp-firmware-smartarray-112204add8-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">HPE </a><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a> </u>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 - 智能阵列P230i、P430、P431、P731m、P830i和P830"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 - Smart Array P230i、P430、P431、P731m、P830i 與 P830"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 업데이트 구성 요소 - 스마트 어레이 P230i, P430, P431, P731m 및 P830i 및 P830"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-05-09T06:13:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>DDR cache could be randomly disabled after several boots</li>\n\t<li>A hot-inserted replacement drive might show as a predictive failure if the original drive was identified as a predictive failure.</li>\n\t<li>Controller cache module might be marked as permanently disabled if the Smart Storage Battery is removed or failed while the system is online, even if SSA was previously used to enable write caching without a backup power source.</li>\n\t<li>Controller can become unresponsive due to a SmartCache pending flush operation when a read-ahead and a read-fill are performed in sequent.</li>\n\t<li>System might stop responding if a parity error is found during surface scan of a RAID6 volume. (POST Lockup 0x13)</li>\n\t<li>System fans might go to 100% if connected drives were spun down</li>\n\t<li>Issue where a controller crash dump may not be collected after a controller failure</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>The firmware updates could fail while SmartCache is enabled due to active I/O in the Smart Cache.</li>\n\t<li>The serial output of the expander could fail to be populated in the controller logs due to the buffer not being handled appropriately by the controller</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103C","sw_key_expectedpath":"firmware"},{"name":"1923103C","sw_key_expectedpath":"firmware"},{"name":"1922103C","sw_key_expectedpath":"firmware"},{"name":"1924103C","sw_key_expectedpath":"firmware"},{"name":"1921103C","sw_key_expectedpath":"firmware"},{"name":"1926103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"6085534","datemodified":"2019-08-07T10:53:16","file_list":["/CP040773.vmexe","/CP040773.vmfile","/CP040773.xml","/README.txt"],"md5sum":"a0759abeee60c9b0b52b3cf0437c736c","name":"CP040773.zip","release":"2019-08-07T15:53:06","revision":"0","sha1sum":"4df7aec7225c5ba70ff64fd31a00ca6d6d4fca7d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019","vib_list":[]}],"id":{"product":"e75e513801aa44c1b7614f2e99083381","version":"8484bf0f92144d509ced7c7e3e8405f4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T23:03:41","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.44_11_13_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.44 (11/13/2020)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17842200","datemodified":"2020-11-18T02:34:42","file_list":["A41_2.44_11_13_2020.signed.flash","cp046096.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"818e50d6a50d3b79fa03a56480beb558","name":"cp046096.exe","release":"2020-11-18T02:32:10","revision":"0","sha1sum":"6e59beb4949d7ad68983de83420874e641325814","size":"17MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"2.44_11-13-2020"}],"id":{"product":"4ecda510f4cf4aef9ac80ad782d1c36e","version":"311be1895f7746e9bc1181d9b202b4aa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325 Gen10 (A41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T02:33:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. </p><p>Added support to increase the maximum amount of system memory to 8TB.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed a rare issue where the system may fail to boot after a warm reset.</p><p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p><p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB2000JFEML and MB4000JFEMN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB2000JFEMLおよびMB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3612760","datemodified":"2020-12-16T18:58:24","file_list":["cp045542.xml","cpqsetup.exe","HAKPNSD6.rel","payload.json","setup.dll"],"md5sum":"3d0be7e128bb2008afe9a773c2db7418","name":"cp045542.exe","release":"2020-12-16T18:45:04","revision":"0","sha1sum":"b1d73ed55623cd7663e00fe06625ab9e82cbd2dd","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"43e2b01e979548ad962efb95de5a6d12","version":"b27909d3749e403c8e698eac34a2eacd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Management Controller Driver Package provides system management support, including monitoring of server components, event logging, and support for the Insight Management Agents and WBEM Providers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"764184","datemodified":"2018-12-03T12:24:19","file_list":["cp037927.xml","cpqsetup.exe","depcheck.dll","hpqilo3core.cat","hpqilo3core.inf","hpqilo3core.sys","hpqilo3service.cab","hpqilo3service.msi","install.xml","multisetup.dll"],"md5sum":"21e5fa3be54b9f929d3d88f74e9ec196","name":"cp037927.exe","release":"2018-12-03T18:23:28","revision":"0","sha1sum":"ae466f5773c646a45b34b3cc47f9dbf1b66c9fdd","size":"746KB","target_guids":[],"type_of_change":"0","version":"4.0.0.0"}],"id":{"product":"0304d65ecdff4ea58d39c91896e3e228","version":"e20968c891b444c6b6de68a73461ce32"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Management Controller Driver Package for Windows Server 2016 and Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-03-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed a component installation failure (error message &quot;The iLO 4 Core Driver must be installed before installing this package&quot;) when Windows Device Guard is enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ProLiantMonitor.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\iLO 3\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"362271","datemodified":"2020-02-05T16:25:34","file_list":["/cp042920.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"e0737390f016bd44de695feeb0de64b6","name":"cp042920.zip","release":"2020-02-05T22:24:05","revision":"0","sha1sum":"4940baedcb79e6d8886a99270224cb15d7bcb658","size":"353KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"e420d2824f1a4f3980b18730d5e2bcc4","version":"3b510f5dfbf04414b2ce803a4d0454fe"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85030G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85030G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VS000480KXALB Drive"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB Drive<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85030G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Added Support for RHEL 8.2</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong>Requires iLO5 v2.30 or later</p>\n"}],"files":[{"bytes":"7562425","datemodified":"2020-07-28T17:35:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/85030G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/CP044273.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85030G00-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044273.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044273.scexe"],"md5sum":"b9302f850f3cee19473cc6a46a87fecf","name":"firmware-hdd-805abb7e9c-85030G00-2.1.x86_64.rpm","release":"2020-07-28T17:24:04","revision":"0","sha1sum":"86cdd830c131bee072c7a4cb912d6d7dd30eff64","size":"7MB","target_guids":["562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85030G00"}],"id":{"product":"f4d3c3f0b12d4c1da09c3d11188e06cf","version":"5a07e8eb07cc4b8193943bcb0ba57b73"},"installation":{"command":"CP042967.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"SK Hynix"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB  Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-29T05:29:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Support for RHEL 8.2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx5は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-4およびConnectX®-5アダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1750695","datemodified":"2020-11-24T06:38:20","file_list":["/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip","/cp046263.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/doc/release_note_nmlx5-core_4.16.70.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/doc/release_note_nmlx5-rdma_4.16.70.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.16.70.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.16.70.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/vibs/nmlx5-rdma--629813285.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/vibs/nmlx5-core--320331276.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_core-4.16.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.70.1-1OEM.650.0.0.4598673-offline_bundle-16388385.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_rdma-4.16.70.1.xml"],"md5sum":"7ceba467ea08e359fa12240a39977112","name":"cp046263.zip","release":"2020-11-24T06:36:05","revision":"0","sha1sum":"0747634ccdd13a7cc45c3ae5894a0eb42a944811","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx5-core","version":"4.16.70.1-1OEM.650.0.0.4598673"},{"name":"nmlx5-rdma","version":"4.16.70.1-1OEM.650.0.0.4598673"}]}],"id":{"product":"b0057e5ba3444c3eb76eb15c0d0d8adc","version":"cdf0e91a583348f492e3386be2af5aa1"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 6.5"},{"lang":"ja","x_late":"nmlx5_enドライバーコンポーネント for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.03.09:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 10/25Gb 2-port 642SFP28 Adapter (HPE Part Number: P24837-B21)</li>\n\t\t<li>HPE Ethernet 10Gb 2-port 548SFP+&nbsp; (HPE Part Number: P11338-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>An event will be sent to notify the administrator if the power required by the network adapter is higher than that available on the PCIe slot.</li>\n\t<li>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</li>\n\t<li>A&nbsp;new counter that enables the user to query per Virtual Function counters.</li>\n\t<li>RX out-of-buffer counter to indicate any lack of software receive buffers.</li>\n\t<li>Module parameter to enforce specific RoCE version.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command was not supported. When running this command on a vmknic, a failure message was displayed.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2020.11.11:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>An event will be sent to notify the administrator if the power required by the network adapter is higher than that available on the PCIe slot.</li>\n\t<li>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</li>\n\t<li>A&nbsp;new counter that enables the user to query per Virtual Function counters.</li>\n\t<li>RX out-of-buffer counter to indicate any lack of software receive buffers.</li>\n\t<li>Module parameter to enforce specific RoCE version.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.16.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command was not supported. When running this command on a vmknic, a failure message was displayed.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"nmlx5-core:4.16.70.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.16.70.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Microsoft Windows Server 2016 執行的 HPE Intel i40ea 10 Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel i40ea 10기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"此组件包包含的驱动程序适用于在 Microsoft Windows Server 2016 环境下运行的 HPE Intel i40ea 10 千兆以太网卡。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1252816","datemodified":"2021-01-08T16:05:03","file_list":["cp045125.xml","cpqsetup.exe","cp_data.xml","i40ea65.cat","i40ea65.din","i40ea65.inf","i40ea65.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"3ea569e075f0ada18b9dc4833d5052f3","name":"cp045125.exe","release":"2021-01-08T15:51:05","revision":"0","sha1sum":"e82538aaaa9fe11bb47799f71768b220db3c3270","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"4c78cfc099d944a5b3790aa796ed8a49","version":"225b70c27c564e63ae180960589bf693"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Intel i40ea 驅動程式"},{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel i40ea 드라이버"},{"lang":"cn","x_late":"Windows Server 2016 版 HPE Intel i40ea 驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40ea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic NX2/FastLinQ userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 SP4 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP4 x86_64で動作するQLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロードのためのARP/DHCPサポートを提供するHPE QLogic NX2/FastLinQ userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"101274","datemodified":"2019-10-25T06:40:30","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio/component.xml"],"md5sum":"43e4cd8f90ad3d48065e48d0ed8dcbb4","name":"iscsiuio-2.11.5.13-3.sles12sp4.x86_64.rpm","release":"2019-11-01T00:00:00","revision":"2","sha1sum":"acc24e4e4da74d8f42821ae1d0889a6b43754a38","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec563dc806"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"97f5388c948445bc9249ae42cebeaaec","version":"ebd1a3072f6e475eadd0816cb5e7a09c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP4"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-12T15:26:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n"},{"curr_enhancements_x_late":"<p>This product no longer supports ProLiant Blade servers and devices. Blade&nbsp;servers and devices&nbsp;are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-e4fc7933c004453e9ae21103a1\">HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP4</a>.</p>\n\n<p>This product no longer supports Synergy servers and devices. Synergy servers and devices are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-396113a4bb074577bd00fdae57\">HPE Synergy QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP4</a>.</p>\n","curr_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iscsiuio","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1022984","datemodified":"2021-01-08T19:21:59","file_list":["cp046118.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"md5sum":"99eacd69f8f6da1183c9fa97b5b4381e","name":"cp046118.exe","release":"2021-01-08T19:07:04","revision":"0","sha1sum":"cbc7dcaf63ce78134fcf9d4d40fe8092da3c6824","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"type_of_change":"0","version":"4.1.219.0"}],"id":{"product":"ab1694a2c3b34d68b6e9d41c15960bf5","version":"b3e0e8c307ae41e7b39514aae9bea9b1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2019"},{"lang":"ja","x_late":"Windows Server 2019用HPE Intel ixsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixs68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡的SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"84600","datemodified":"2021-01-09T00:52:36","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"5bfddf93882b52d8f3bd3ccc12d02a1d","name":"kmod-hp-iavf-4.0.2-1.rhel7u8.x86_64.rpm","release":"2021-01-09T00:41:05","revision":"0","sha1sum":"d4d1cd6b330843bd21206193509c686640df8eff","size":"82KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.0.2-1"},{"bytes":"84599","datemodified":"2021-01-09T00:49:52","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"0f99b614f036633d76d86035fcd8c77e","name":"kmod-hp-iavf-4.0.2-1.rhel7u9.x86_64.rpm","release":"2021-01-09T00:41:05","revision":"0","sha1sum":"c761c57244438613ea6dbc0649911726e70b0bf8","size":"82KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.0.2-1"}],"id":{"product":"58d1a656061f4ce896db266c33677e70","version":"430dfb3f9f934de2b59d23a493b9f371"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1126992","datemodified":"2021-01-08T21:23:45","file_list":["cp045320.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"d8d884b3bb5eb1e8feea18b092c52f96","name":"cp045320.exe","release":"2021-01-08T21:09:04","revision":"0","sha1sum":"ef0f9f1235a22119c7b3875016e1a4a8d88b477e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"6510bb61b44e4df589649e5642d32bf1","version":"c6869321e71c44bea189b0050a1e9cf5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i40ea Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"i40ea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5583018","datemodified":"2020-12-13T15:55:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/CP045471.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/SCIMARRNETG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045471.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045471.scexe"],"md5sum":"b283486a3692384d7403385498907e1f","name":"firmware-hdd-18e328f036-HPG2-3.1.x86_64.rpm","release":"2020-12-13T15:44:04","revision":"0","sha1sum":"73bae3a80485d925eafae18272a5045326c8bd63","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"862d36dd920c478ca6dcfdb5f392893a","version":"7d1e6e78fdb44ef79826161c653da5e0"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contain the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2012 R2用HPE Broadcom NetXtreme-E デバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"955776","datemodified":"2020-01-11T01:33:03","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp041785.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"9706a882220fbd48cc46c6b81b539c2a","name":"cp041785.exe","release":"2020-01-11T01:18:05","revision":"0","sha1sum":"44f3627e8fa25f751fa573e47158ddffd90ef135","size":"933KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"214.0.247.1"}],"id":{"product":"b4038948946c452fb5d749b985ef4ee9","version":"6bf82d92a8a449d8b8492c74573c484b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-14T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports&nbsp;the following network adapters.</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</li>\n</ul>\n","curr_fixes_x_late":"<p>This product correct an issue which .max SRIOV VFs are not loading when Windows hypervisor and Windows VMs are used.<br />\nThis product correct an issue which VF driver won&#39;t install on some devices.<br />\nThis product correct an issue which FW hangs while allocating more PF-Vports<br />\nThis product correct an issue which fail bono commands right away if HW is surprise removed<br />\nThis product correct an issue which few VPORTS available in SF mode when SR-IOV is used.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel over Ethernet Driver kit for HPE Storage Emulex(BRCM) Converged Network Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1151743","datemodified":"2021-01-22T10:20:54","file_list":["/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip","/cp042523.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/brcmfcoe-12.0.1278.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/doc/README.txt","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/doc/release_note_brcmfcoe_12.0.1278.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/vendor-index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/vib20/brcmfcoe/EMU_bootbank_brcmfcoe_12.0.1278.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0.xml","/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-14897888.zip/VMW-ESX-6.7.0-brcmfcoe-12.0.1278.0-offline_bundle-14897888.zip/metadata.zip/vibs/brcmfcoe--8968480398887381165.xml"],"md5sum":"b776d01c49794a3e9452902ec68c3af7","name":"cp042523.zip","release":"2021-01-22T10:20:06","revision":"0","sha1sum":"65db8edd10cc86798f805241ea0f6231a2f7134d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2e31a109"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmfcoe","version":"12.0.1278.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"0149953b59694d068d7ec0cd6a92031e","version":"ae530ca59bdf4fee9ff85d59b9ed0403"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex(BRCM) Fibre Channel over Ethernet driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:33:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to Driver version 12.0.1278.0</p>\n","latest_fixes_x_late":"<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<p>Fixed the following:</p>\n\n\t\t\t<ul>\n\t\t\t\t<li>Purple Screen of Death(PSOD) at random intervals on HPE FlexFabric 20Gb 2-port 650FLB Adapter</li>\n\t\t\t\t<li>Link down after 1000 times port down and up iterations on switch.</li>\n\t\t\t\t<li>Detaching is not completing because lpfc_do_work_event can&#39;t exit.</li>\n\t\t\t\t<li>Slab memory use after free causing memory leak.</li>\n\t\t\t\t<li>Small Computer Sytem Interface(SCSI) command is used after done call.</li>\n\t\t\t\t<li>Target reset does not report original status</li>\n\t\t\t</ul>\n\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\n\t\t\t<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex&nbsp;XE-102 Based&nbsp;Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following&nbsp;link:</p>\n\n\t\t\t<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>&nbsp;</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to Driver version 12.0.1278.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe:12.0.1278.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_1.0.7s.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.7"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"203115","datemodified":"2021-01-15T08:06:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/CP046569.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/PICGen10_1.0.7s.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.7-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046569.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046569.scexe"],"md5sum":"f6dcfeadd83cb9fdfbc36a4eab452073","name":"firmware-powerpic-gen10-1.0.7-4.1.x86_64.rpm","release":"2021-01-15T07:57:04","revision":"0","sha1sum":"1069d0e0152af35a99148dad76d31bb44f06bbd6","size":"198KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.7"}],"id":{"product":"d6cef3e7c9484a989ca5a04fc11b29f2","version":"944820e8913042e0aeb3f78519804029"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Workstation (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-15T07:53:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.7 (B) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7.  It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.<br>&nbsp;<P><B>Firmware Dependencies:</B></P>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.<P><B>Enhancements/New Features:</B></P>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors.   iLO5 version 1.40 or above is required to upgrade to this version.<p>This is the initial version for HPE Gen10 Plus servers.<P><B>Known Issues:</B></P>None","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (D) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (D) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.<br />\n&nbsp;</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2299136","datemodified":"2021-01-22T07:48:50","file_list":["cp044734.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"f8c21210a8fce4f00a0b209504bad342","name":"cp044734.exe","release":"2021-01-22T07:45:06","revision":"0","sha1sum":"f09d80305857e0f8a6f5f300d612a23b47782ca0","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"C8510","version":"af07065896cd4674abe33248260301a2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.6.165.0</p>\n\n<p>Added the following support :</p>\n\n<p><br />\nRemoved the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1667688","datemodified":"2021-01-22T05:02:47","file_list":["./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"852c39e2e52b2db63136c44b3f28c023","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles12sp5.x86_64.rpm","release":"2021-01-22T04:57:25","revision":"0","sha1sum":"d8d4f038f44847352870617201b3f974e0f551d0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"},{"bytes":"1667795","datemodified":"2021-01-22T05:07:21","file_list":["./opt/broadcom/sles12sp4/i386/lib/libbrcmdfc.so","./opt/broadcom/sles12sp4/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles12sp4/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp4/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles12sp4/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles12sp4/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles12sp4/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles12sp4/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp4/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles12sp4/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"75addc89d30b38beba18506d7c687fc8","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles12sp4.x86_64.rpm","release":"2021-01-22T04:57:25","revision":"0","sha1sum":"c67b2c5dfb4ede574342871ba6d562d3cc689864","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"a3459c07ef5f45fe84a4a598d99e1833","version":"5f4d755ef4b64e9fad251cf170f9eedb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:52:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1264.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS2, provides Windows 2012 R2 64-bit support for HPE Smart Array P824i-p MR 64-bit controller"},{"lang":"ja","x_late":"このドライバーMegaSAS2は、HPE Smart Array P824i-p MR 64-bitコントローラー用のWindows 2012 R2 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1160168","datemodified":"2019-01-23T23:34:50","file_list":["cp034410.xml","cpqsetup.exe","generic.dll","install.xml","megasas2.cat","MegaSAS2.inf","megasas2.pdb","megasas2.sys","nodev.inf"],"md5sum":"d99ac6f74f9c298508bcd61c5d5cd5b6","name":"cp034410.exe","release":"2019-01-24T05:34:01","revision":"0","sha1sum":"9e2b13d9bdefe03fddc1ea9cea1861fcd6b16dab","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9d4f074d"],"type_of_change":"1","version":"6.714.18.0"}],"id":{"product":"cfae6248bdc149bc8eddf29048411fb5","version":"719de46265e845d0b48aae0420646276"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR 64-bit controller driver for Microsoft Windows 2012 R2 edition."},{"lang":"ja","x_late":"Windows 2012 R2 エディション用HPE Smart Array P824i-p MR 64-bitコントローラードライバー。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-02-02T06:38:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial driver release for HPE Smart Array P Class MR Gen10 controllers.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MegaSas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.77"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.77"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、NCSI、iSCSI、FCoEおよびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.77 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.15.80</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.8.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"4563224","datemodified":"2020-12-09T21:57:12","file_list":["BNICOFUT.pdf","cp045080.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.18.77.bin","ja/","ja/BNICOFUT_JA.pdf","LibQLGC_HpFwUpg.dll","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"70684922759d145bc28ff6a90375cf23","name":"cp045080.exe","release":"2020-12-09T21:43:04","revision":"0","sha1sum":"4c265218a2793eadcea5ffdc946b0052ca32ab5d","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"1","version":"1.0.2.2"}],"id":{"product":"7ba136be4b834a5699f5c5fff754d07b","version":"d6c16793f2164c92994afc7c6a382088"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR>\n<P>［インストール］ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product has been rebuilt with the correct digital signature. It does not require dual signatures.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;19.12.13.0.</p>\n"}],"files":[{"bytes":"219344","datemodified":"2020-04-27T23:43:27","file_list":["/cp041295.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/vib20/i40en/INT_bootbank_i40en_1.10.9.0-1OEM.700.1.0.15525992.vib","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vmware.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/vibs/i40en--20899530716261387.xml","/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992_16030650.zip/metadata.zip/bulletins/Intel-i40en_1.10.9.0-1OEM.700.1.0.15525992.xml"],"md5sum":"62bed828ec6dd0c4ae5c3a62e0d60361","name":"cp041295.zip","release":"2020-04-28T04:42:04","revision":"0","sha1sum":"2c891490b5c4061dd21c76ff7c0540d82bb1883a","size":"214KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","20a6e8e4-bf33-4c71-a6bf-d9ec09108524"],"type_of_change":"0","version":"2020.05.29","vib_list":[{"name":"i40en","version":"1.10.9.0-1OEM.700.1.0.15525992"}]}],"id":{"product":"d892124a7e30440eb7f95535da6dada7","version":"4d2addac81bf4876b47f54925d3f1ecc"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-02T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40en:1.10.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-i40en:1.10.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK74H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3およびMZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"25197700","datemodified":"2021-02-11T15:46:25","file_list":["/CP046470_BUILD_6.data","/CP046470.vmexe","/CP046470.vmexe64","/CP046470.vmfile","/CP046470_VMw.zip","/CP046470.xml","/payload.json","/CP046470_VMw.zip/index.xml","/CP046470_VMw.zip/vendor-index.xml","/CP046470_VMw.zip/metadata.zip","/CP046470_VMw.zip/vib20/CP046470/HPE_bootbank_CP046470_EPK74H3Q.6-7.0.0.15843807.vib","/CP046470_VMw.zip/metadata.zip/vendor-index.xml","/CP046470_VMw.zip/metadata.zip/vmware.xml","/CP046470_VMw.zip/metadata.zip/vibs/CP046470--6112866558183264708.xml","/CP046470_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046470_EPK74H3Q.6-7.0.0.15843807.xml"],"md5sum":"901c97f8134b1407549b978b7f563a1a","name":"CP046470.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"3c9405517f0918177da45e951c3e3235261f844f","size":"24MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK74H3Q","vib_list":[{"name":"CP046470","version":"EPK74H3Q.6-7.0.0.15843807"}]}],"id":{"product":"a1d749637b0b455e9a43d66fc6eed023","version":"3f2c82eed2a34e6c990bf231a12647b6"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor VMwareESXi - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T07:53:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1536160","datemodified":"2021-01-08T16:49:56","file_list":["cp045128.xml","cpqsetup.exe","cp_data.xml","i40eb65.cat","i40eb65.din","i40eb65.inf","i40eb65.sys","i40ebmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicIn40B.dll"],"md5sum":"429d2cd01d17e1dae160a37fcfc7eda5","name":"cp045128.exe","release":"2021-01-08T16:36:05","revision":"0","sha1sum":"51303220f249c7177f9e67314ca6c111c53386f2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"13683c4504bf424989ac644f48168972","version":"e2fb2b6721a540fba805742d272e28c8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel i40ebドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.<br />\n&nbsp;</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40eb65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2031725","datemodified":"2020-12-02T16:58:13","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"93ed69321510d2ec9b4173396d048fe7","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp2.x86_64.rpm","release":"2020-12-02T15:00:05","revision":"0","sha1sum":"3c643fc837a891bcf742cb9922040662c77b21a2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"},{"bytes":"2019474","datemodified":"2020-12-02T17:01:58","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/vfio","./lib/modules/5.3.18-22-default/updates/drivers/vfio/mdev","./lib/modules/5.3.18-22-default/updates/drivers/vfio/mdev/i915.ko","./lib/modules/5.3.18-22-default/updates/drivers/vfio/mdev/kvmgt.ko","./lib/modules/5.3.18-22-default/updates/drivers/vfio/mdev/mdev.ko","./lib/modules/5.3.18-22-default/updates/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"e1b753470402dc143a63b3b9e3960174","name":"mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.2.2.4.1.sles15sp2.x86_64.rpm","release":"2020-12-02T15:00:05","revision":"0","sha1sum":"6f16de8ec13d6fc2ca0fb28abf202a086b189626","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9"}],"id":{"product":"7af26f11b3bd4a2f99d0fd0dcc72a2db","version":"8194eda63ba64db4be7d308d8cc1502c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using &nbsp;5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles15sp2.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.2.2.4.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:57:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.20 (10/27/2020)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8889560","datemodified":"2020-11-02T15:10:56","file_list":["cp045740.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_2.20_10_27_2020.signed.flash"],"md5sum":"e20bade9558dc1d59e325ef6b1c075bd","name":"cp045740.exe","release":"2020-11-02T15:09:06","revision":"0","sha1sum":"32e96da8728d1a9e194ded9bfcb3949fefb8e7af","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"0","version":"2.20_10-27-2020"}],"id":{"product":"f22e031456d1410688940c3efe38cf1d","version":"04067fbbcc864412a59ba814029eb6ab"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T03:37:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode for Intel Pentium processors which provides mitigations for security vulnerabilities documented as CVE-2020-0543 as well as CVE-2020-0548 and CVE-2020-0549. These security vulnerabilities are documented in Intel Security Advisories INTEL-SA-00320 and INTEL-SA-00329. These issues are not unique to HPE servers. This update does not impact systems using Intel Xeon based processors.</p>\n\n<p>Addressed an issue where the system would become unresponsive with a Red Screen or hang when booting to FreeBSD R12.1 from a USB device when in Legacy Boot Mode. This issue did not impact systems configured for UEFI Boot Mode or when booting from other types of media.</p>\n\n<p>Addressed an issue where a dual port networking device may show up in the System Configuration Utilities with two Port 1 names instead of properly being represented as Port 1 and Port 2. This did not impact any functionality to the device.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.</p>\n\n<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n\n<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.</p>\n\n<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK, and MO3200JFFCL Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MO0400JFFCF、MO0800JFFCH、MO1600JFFCKおよびMO3200JFFCLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5033650","datemodified":"2020-12-13T16:26:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/CP045481.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/GP1635D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045481.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045481.scexe"],"md5sum":"901ea0dfcd70d15d46036037e1b6e8d0","name":"firmware-hdd-edf6dcd906-HPD9-3.1.x86_64.rpm","release":"2020-12-13T16:15:04","revision":"0","sha1sum":"b517b51b6c01a24c548a28cca29d0f0078184c86","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"436670aad3944dd794f4bdcf4feb2b72","version":"35721f927f6d4570b1d55be7127e391f"},"installation":{"command":"CP042217.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"382659","datemodified":"2015-07-28T14:58:09","file_list":["./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/.cpq_package.inc","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/.hpsetup","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/CP027686.xml","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/SNARFR41.hex","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/firmware.ini","./usr/lib/i386-linux-gnu/hp-firmware-powerpic-dl580-4.1-5/hpsetup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP027686.scexe"],"md5sum":"6518c0f27396be8b9cb7b12524ac23df","name":"hp-firmware-powerpic-dl580-4.1-5.i386.rpm","release":"2015-07-28T14:59:18","revision":"0","sha1sum":"7339e25f3f1d7c4a27db2aca05d26fa5f8842b13","size":"373KB","target_guids":[],"type_of_change":"1","version":"4.1"}],"id":{"product":"1fda2856afe34ef885a535a6a8013679","version":"c8180f8a3240446a9bd22383987ee57d"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HP ProLiant Agentless Management Service (hp-ams) and HP SNMP Agents (hp-snmp-agents) are both running.&nbsp; HP does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;HP Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\hp\\swpackages on the USB key.</p>\n\n\t<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\t</li>\n</ul>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Power Management Controller "},{"lang":"ja","x_late":"オンラインROMフラッシュ for Linux - Power Management Controller "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2015-08-28T14:35:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>\n <strong>Important Notes:</strong><br />\n Ver. 4.1(D) contains updates to the OS installation support for HP Smart Update Manager. The Power Management Controller Firmware contained within Ver. 4.1(D) is Ver. 4.1. Therefore, it is not necessary to upgrade with ver. 4.1(D), if the Power Management Controller firmware version is 4.1.</p>\n<p>\n <b>Firmware Dependencies:</b></p>\nNone\n<p>\n <b>Enhancements/New Features:</b><br />\n This is the initial version of the firmware.<br />\n <b>Known Issues:</b></p>\nThe smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E)&nbsp;contains a change to the Firmware RPM install command name from &ldquo;cpqsetup&rdquo; to &ldquo;hpsetup&rdquo; and is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;E if a previous component revision was used to upgrade the firmware to version 4.1.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HP ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) -&nbsp; MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5381744","datemodified":"2021-01-25T05:53:24","file_list":["cp045598.xml","cpqsetup.exe","GP1725b0HPK3.rel","payload.json","setup.dll"],"md5sum":"602f264fc2c5a17eb387356e5cea8ebe","name":"cp045598.exe","release":"2021-01-25T05:44:04","revision":"0","sha1sum":"e259cbcc554d9b8a1f924cbe0eccd693f873ca31","size":"5MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"12eaa829eeb841af89f7ea134993346e","version":"4489c20d5cef4c96a356ba1e48b37e34"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:09:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue where the SSID was not programmed correctly to the drive. This may cause issues with the drive not being identified correctly in the Integrated Lights Out Utility.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6085162","datemodified":"2020-12-13T09:26:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/CP045414.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/HVLAeAsseFD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045414.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045414.scexe"],"md5sum":"27e09d49e557d255d238098e4dbacae6","name":"firmware-hdd-a886842a99-HPD1-4.1.x86_64.rpm","release":"2020-12-13T09:12:05","revision":"0","sha1sum":"85f441a07883b8f17252ffe660c072afa6a66511","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"9ea83d5d4cdf449690664479d7c8538a","version":"20406557fd7c4a87a0d7c8d4d1ab8d46"},"installation":{"command":"CP041488.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1260774","datemodified":"2021-01-27T01:16:15","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/libexec/rdma-set-sriov-vf","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.0","./usr/share/doc/dpcp-1.1.0/README","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibverbs-52mlnx1","./usr/share/doc/libibverbs-52mlnx1/libibverbs.md","./usr/share/doc/librdmacm-52mlnx1","./usr/share/doc/librdmacm-52mlnx1/librdmacm.md","./usr/share/doc/libvma-9.2.2","./usr/share/doc/libvma-9.2.2/README.txt","./usr/share/doc/libvma-9.2.2/VMA_VERSION","./usr/share/doc/libvma-9.2.2/journal.txt","./usr/share/doc/rdma-core-52mlnx1","./usr/share/doc/rdma-core-52mlnx1/COPYING.BSD_FB","./usr/share/doc/rdma-core-52mlnx1/COPYING.BSD_MIT","./usr/share/doc/rdma-core-52mlnx1/COPYING.GPL2","./usr/share/doc/rdma-core-52mlnx1/COPYING.md","./usr/share/doc/rdma-core-52mlnx1/README.md","./usr/share/doc/rdma-core-52mlnx1/tag_matching.md","./usr/share/doc/rdma-core-52mlnx1/udev.md","./usr/share/licenses/dpcp-1.1.0","./usr/share/licenses/dpcp-1.1.0/LICENSE","./usr/share/licenses/libvma-9.2.2","./usr/share/licenses/libvma-9.2.2/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"2a073483fc0ca8380eed343d763b27ff","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u9.x86_64.rpm","release":"2021-01-26T23:17:08","revision":"0","sha1sum":"a06cc2d3e8bb8934713b8b6b5382cf8a77f43470","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.2"},{"bytes":"1315747","datemodified":"2021-01-27T01:14:25","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"9360669ed816f0741111ab1716c711f9","name":"kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u9.x86_64.rpm","release":"2021-01-26T23:17:08","revision":"0","sha1sum":"5f6921aaa5e39c4e560b4c4b0e02bce1d0a360ca","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.2"}],"id":{"product":"ac732738370b4df180761b2b7435b65d","version":"8cc5e08a22ab42849b1a7da7c7be4841"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u9.x86_64.rpm mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"540048","datemodified":"2020-07-21T17:51:46","file_list":["C620.dll","cp044968.xml","cpqsetup.exe","instC620.dll","lewisburg.cat","LewisburgSystem.inf","Skylake-E.cat","Skylake-ESystem.inf"],"md5sum":"584fd543d0b6a981b7b65504fecd365f","name":"cp044968.exe","release":"2020-07-21T17:49:28","revision":"0","sha1sum":"7e289959337111f1f4545a8161a7440b69fdbf21","size":"527KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece3d9f233"],"type_of_change":"0","version":"10.1.18435.8224"}],"id":{"product":"21c71338fdf2430b8b41f3737620822c","version":"814f238dee7b4a9588056b3a0ea8a2c3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Windows"},{"lang":"ja","x_late":"Windows用Intel Xeonスケーラブルプロセッサー（第1および第2世代）識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T17:26:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Intel devices 203A, 203D, 2078, and 207A.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Add support for Intel devices 201A, 201C, and 206F</li>\n\t<li>Add support for Superdome Flex 280</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"C620.dll","sw_key_expectedpath":"%ProgramFiles%\\Chipset software"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2286584","datemodified":"2020-12-03T19:34:13","file_list":["cp044768.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"1b1a918dc1c7ae2c921944b40d89ae07","name":"cp044768.exe","release":"2020-12-03T19:25:04","revision":"0","sha1sum":"3542943640dc1964e3d2ddeabdbfdbcc6d771b23","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"d40709c9a4334c3ab0e384d0ba51692d","version":"6d06d77f70f74d90abbf8d17fa8d1b5f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2/2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:01:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.6.165.0</p>\n\n<p>Added the following support :</p>\n\n<p><br />\nRemoved the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Hyper-V Virtual Machines (VMs) could not access storage arrays if those Virtual Machine (VM) had been shut down and restarted over 512 times.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD2"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"2990240","datemodified":"2020-12-11T12:19:22","file_list":["cp045772.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEe0HPD2.REL"],"md5sum":"dbc493b26efdfe14a16005ab0895613a","name":"cp045772.exe","release":"2020-12-11T12:08:04","revision":"0","sha1sum":"6ce010da7527f93a700a3dd6afc73496c1f8f513","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"057a33153b064c9280dd7da9d3d5a47a","version":"98a4c216ad7e4be4a13823247bb7e861"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T14:32:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR216i-a","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-a_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7490144","datemodified":"2021-02-26T07:07:07","file_list":["HPE_MR216i-a_Gen10P_52.16.3-3913.ilo","HPE_MR216i-a_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"ffe0d98b0b10c76cc28b5ac3d8bcf674","name":"HPE_MR216i-a_Gen10P_52.16.3-3913.fwpkg","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"7516c30abaef5fc9cc9e7bbbe2d8c42e07855bfb","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032c"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"2b01702f6be343c09f8208f8aab17afb","version":"df62412c2fe54a5d872f45a3b6af929d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR216i-a Gen10 Plus Tri Mode Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T07:11:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"032C1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGE"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGE"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGE"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGE"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGE"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGE"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGE"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK&nbsp;and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5011946","datemodified":"2020-12-13T15:18:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/CP045232.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/M5100SGE.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGE-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045232.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045232.scexe"],"md5sum":"24ea8023ba4d7d693ec12fe835318132","name":"firmware-hdd-3db7640485-HPGE-5.1.x86_64.rpm","release":"2020-12-13T15:06:08","revision":"0","sha1sum":"8146a74a8e64b5ecddef84551fc8ab628522fd37","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"0","version":"HPGE"}],"id":{"product":"8c0c47d5bf1446e88cb749de3c7fd2d0","version":"8bb5c32f66374026a4d568c1fa5a68f1"},"installation":{"command":"CP041319.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子のついていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-14T05:32:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11156801","datemodified":"2021-01-28T09:38:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/CP046631.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/U33_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046631.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046631.scexe"],"md5sum":"cacbb72a901f34f627b282f0355a0534","name":"firmware-system-u33-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T09:26:20","revision":"0","sha1sum":"606c5889bb8b5f707400307b69538e4c3e89315f","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"dea19449209743ffa1d2262e07eafb25","version":"42fd7e868a8949fbb1ff1298af627855"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML110 Gen10 (U33)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel Driver kit for HPE Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"803045","datemodified":"2020-11-04T08:46:16","file_list":["/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip","/cp044771.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.329.0-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/vibs/lpfc-9162685171387925875.xml","/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807_16969162.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.329.0-1OEM.700.1.0.15843807.xml"],"md5sum":"e934a837a27852a6a9e46339c41fba2b","name":"cp044771.zip","release":"2020-11-04T08:45:04","revision":"0","sha1sum":"85f63198499d01be6d4a43cc707b8eeac83fa7a7","size":"784KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7654434b","20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.329.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"4e7d93b236d542028248e102c6a2c879","version":"1f7b7522f66e413f98b8830c770ce432"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:01:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.6.228.4</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.329.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"Broadcom-ELX-lpfc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"lpfc:12.8.329.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."},{"lang":"cn","x_late":"Smart Storage Administrator (SSA)是一款基于 web 的应用，可帮助您配置、管理、诊断和监控智能阵列管理器，且现在还可支持其他存储设备，如主机总线适配器（HBA）、存储控制器，未来还可支持 SCSI Express 驱动器以及 SAS 交换机设备。Smart Array Advanced Pack 1.0 和 2.0 特性现在是 SSA 基本特性的一部分（包含相应的固件）。"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) は、Smartアレイコントローラーや他のストレージデバイス、例えばホストバスアダプター(HBA)、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。Smart Array Advanced Pack 1.0および2.0の機能は、適切なファームウェア(の使用)によりSSAのベースライン機能の一部となりました。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Please make sure the following browser options are enabled:</p>\n\n<ul>\n\t<li>Automatically load images and other data types.</li>\n\t<br />\n\t<li>JAVA script</li>\n\t<br />\n\t<li>Style sheets</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"11620689","datemodified":"2021-01-26T19:05:41","file_list":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"md5sum":"98b477f2335eb4d8167731d65720d694","name":"ssa-5.10-44.0.x86_64.rpm","release":"2021-01-26T18:57:04","revision":"0","sha1sum":"4f1d716c2641cae33b8096f05fe2e789d5cdfb0a","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"type_of_change":"0","version":"5.10.44.0"}],"id":{"product":"39676e9bd8d74e11b8837e3f6ebabd5c","version":"3754ba59b53149a185dd16db107b1533"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Linux 64-bit"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-22T15:24:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4372744","datemodified":"2020-12-16T22:21:27","file_list":["cp045533.xml","cpqsetup.exe","HLEBHasseFG2.rel","payload.json","setup.dll"],"md5sum":"f397b2d9c54db3bbcc9f8a3a32d33c4c","name":"cp045533.exe","release":"2020-12-16T21:41:07","revision":"0","sha1sum":"3c822306a6aacdf7976c03953f315660194d8d28","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"074cd65cf284444dbd64a63e5f809ff6","version":"954f5c0d87144a1e90942920580ae751"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:43:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic,&nbsp;version 1.0.57.0</li>\n\t<li>qfle3i,&nbsp;version 1.1.5.0</li>\n\t<li>qfle3,&nbsp;version 1.1.12.0</li>\n\t<li>qfle3f,&nbsp;version 1.1.14.2</li>\n</ul>\n"}],"files":[{"bytes":"1384221","datemodified":"2021-01-18T03:41:26","file_list":["/cp044987.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.12.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.14.2-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.57.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3--2209508695182818550.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3f-6322780130870546795.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qcnic-5446603038068585093.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922.xml"],"md5sum":"c31fca86441ec325c6d4d14b0d56d925","name":"cp044987.zip","release":"2021-01-18T03:40:05","revision":"0","sha1sum":"b914b42be5719aa27a2d2f327afb68fc2e11bf57","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qfle3","version":"1.1.12.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3f","version":"1.1.14.2-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.57.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"c5169d515a774f51aa01a14f6284794f","version":"726513d685ec405996d8e7241b191a52"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"VMware vSphere 6.7用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where Purple Screen Of Death(PSOD) when ethernet link connected to 533FLR-T/536FLR-T Adapters.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen during traffic scheduling.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qfle3:1.1.12.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.57.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.14.2-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Management Controller Driver Package provides system management support, including monitoring of server components, event logging, and support for the Insight Management Agents and WBEM Providers."},{"lang":"ja","x_late":"iLO 4マネジメントコントローラードライバーパッケージは、サーバーコンポーネントの監視、イベントログなどのシステム管理のサポート、およびInsightマネジメントエージェントとWBEMプロバイダーのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1102112","datemodified":"2018-10-02T17:36:58","file_list":["cp035109.xml","cpqsetup.exe","depcheck.dll","hpqilo3core.cab","hpqilo3core.msi","hpqilo3service.cab","hpqilo3service.msi","install.xml","multisetup.dll"],"md5sum":"14c02da58c33c245c2feae3efcd44979","name":"cp035109.exe","release":"2018-10-25T00:00:00","revision":"1","sha1sum":"5a74bd3dd7536b2cdf2a82d0704394b99e013c1f","size":"1MB","target_guids":[],"type_of_change":"0","version":"4.0.0.0"}],"id":{"product":"c55c1821244f45499ef3e6eefbb25ee1","version":"ac37e1a512c0461e9e95e70d3cf6c554"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows X64"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件放在臨時目錄中，按兩下執行。<p>選擇「Install（安裝）」開始解壓縮至硬碟上的一個臨時位置。   <p>按一下「Install（安裝）」繼續進行驅動程式的安裝。"},{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ko","x_late":"스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.<p>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.   <p>\"설치\" 버튼을 클릭하여 드라이버 설치 작업을 시작합니다."},{"lang":"cn","x_late":"将智能组件置于临时目录中，然后双击运行。<p>选择“安装”，开始提取至硬盘的临时位置。   <p>点击“安装”按钮继续执行驱动程序安装。"},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリ ディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリ ディレクトリに解凍します。   <p>インストール ボタンをクリックしてドライバー インストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Management Controller Driver Package for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"iLO 4マネジメントコントローラードライバーパッケージfor Windows Server 2012および2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-02-03T20:09:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant:</p>\n\n<ul>\n\t<li>Removed support for Windows Server 2008 and Windows Server 2008 R2.</li>\n\t<li>Removed support for iLO 3.</li>\n\t<li>Removed support for HP ProLiant G7 and HP ProLiant Gen8 systems.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ProLiantMonitor.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\iLO 3\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"963792","datemodified":"2020-06-03T02:02:24","file_list":["cp042037.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo5.dll","nicdrvr.dll","NicInVXS.dll","vxs65x64.cat","vxs65x64.din","vxs65x64.inf","vxs65x64.sys","vxsmsg.dll"],"md5sum":"dedf9b84da0bc61cb6a56f4a841af1c2","name":"cp042037.exe","release":"2020-06-03T01:48:06","revision":"0","sha1sum":"255dadc23eaca8c2b594db4461627182c60bc366","size":"941KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5c427f56"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"a786a49cd75640888a37e362b009fb3c","version":"ad109d8b4cbb45eba1957689ba0511ec"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic FastLinQ Open-iSCSI driver for QLogic FastLinQ NICs running under SUSE Linux Enterprise Server 12 SP4."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP4で動作するQLogic FastLinQ NIC用のHPE QLogic FastLinQ Open-iSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1363881","datemodified":"2019-10-07T17:12:00","file_list":["./sbin/iscsiadm.ql","./sbin/iscsid.ql","./sbin/iscsistart.ql","./usr/share/smartupdate/qlgc-open-iscsi/component.xml"],"md5sum":"f9184d34d569ca240d61e30bf86bdcfb","name":"qlgc-open-iscsi-2.0_873.113.sles12sp4-1.x86_64.rpm","release":"2019-11-01T00:00:00","revision":"1","sha1sum":"4d1ba0484b43a9f6ba07d99d1fdc4025f0796582","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17f154d7"],"type_of_change":"0","version":"2.0-873.113-1"}],"id":{"product":"1e56a84a25b64abe8843f631fbdeb34d","version":"acecb19d0bb04b1589b16e34691e9952"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package&nbsp;provided by&nbsp;this product is a&nbsp;pre-compiled kernel module driver&nbsp;built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp;HPE has tested and approved this&nbsp;pre-compiled kernel module RPM&nbsp;for use with the specified kernel.&nbsp;</p>\n\n<p>This pre-compiled RPM package&nbsp;may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。 HPEは、このコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>このコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Open-iSCSI Driver for SUSE Linux Enterprise Server 12 SP4"},{"lang":"ja","x_late":"HPE QLogic FastLinQ Open-iSCSIドライバー for SUSE Linux Enterprise Server 12 SP4"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-12T21:54:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product no longer supports Synergy servers and devices. Synergy servers and devices are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-1c21454a8fb541f4a27afc84c2\">HPE Synergy QLogic FastLinQ Open-iSCSI Driver for SUSE Linux Enterprise Server 12 SP4</a>.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"qlgc-open-iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.1.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1444440","datemodified":"2021-01-22T10:00:41","file_list":["cp044785.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"9d0a18b860527301634e3cd0a482c03f","name":"cp044785.exe","release":"2021-01-22T09:56:05","revision":"0","sha1sum":"2ce9446b67f25d25628d7a7df6cc0d2b165d8071","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.1.20"}],"id":{"product":"b95f6b9ec4c246469be03e39a2db0a69","version":"b446fd4fbb8b47a1a8481601c130cead"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為一個自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br />\n<br /> 從該磁碟和目錄，執行下載的檔案。<br />\n<br /> 按一下 Install (安裝) 按鈕，以繼續執行安裝程序。<br />\n"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br />\n<br /> 드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<br />\n<br /> \"설치\" 버튼을 클릭하여 설치 작업을 진행합니다.<br />\n"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br />\n<br /> 在该硬盘目录中，执行下载的文件。<br />\n<br /> 点击“安装”按钮进行安装。<br />\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br /> <br /> そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br /> <br /> [インストール]ボタンをクリックして、インストールを開始します。<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"9726946","datemodified":"2020-07-13T13:08:20","file_list":["/CP044443_BUILD_29.data","/CP044443.vmexe","/CP044443.vmexe64","/CP044443.vmfile","/CP044443_VMw.zip","/CP044443.xml","/payload.json","/CP044443_VMw.zip/index.xml","/CP044443_VMw.zip/vendor-index.xml","/CP044443_VMw.zip/metadata.zip","/CP044443_VMw.zip/vib20/CP044443/HPE_bootbank_CP044443_24.23.0.0043.29-7.0.0.15843807.vib","/CP044443_VMw.zip/metadata.zip/vendor-index.xml","/CP044443_VMw.zip/metadata.zip/vmware.xml","/CP044443_VMw.zip/metadata.zip/vibs/CP044443--9086881144583429429.xml","/CP044443_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044443_24.23.0.0043.29-7.0.0.15843807.xml"],"md5sum":"83071e79841cc5e75d8da1a0a047f9e1","name":"CP044443.zip","release":"2020-07-13T13:06:05","revision":"0","sha1sum":"f84cbccf9f635a920cee92369d64ca0870d0dce8","size":"9MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"0","version":"24.23.0-0043","vib_list":[{"name":"CP044443","version":"24.23.0.0043.29-7.0.0.15843807"}]}],"id":{"product":"b9e7f18a1693495cbaf0b6cf2ac1c5fb","version":"0d7b08ed663d47e2a860714f4492393d"},"installation":{"command":"CP044443.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, extract the Smart Component tp temporary folder. For example: ./CPXXXXXX.vmexe --unpack=tmp</li>\n\t<li>Change directory to&nbsp;tmp folder&nbsp;location</li>\n\t<li>Execute ./flash_ctrl_1.04.sh</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for ESXi (x86) - HPE Smart Array P824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-06-29T06:06:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for the Apollo 4510 system</p>\n","curr_fixes_x_late":"<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4202166","datemodified":"2021-03-08T20:09:31","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbe","./lib/modules/4.12.14-195-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"5bb6365255c19eea87674f7548864bff","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"7884b01cc5e342e777142e26358d84f6d428dd9d","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4991622","datemodified":"2021-03-08T20:10:55","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"d2d5089730ce54447d91283791a01f40","name":"hp-ixgbe_bl-kmp-default-5.9.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"5580ad40a933fa32894fcf1ec7d2922156b2b3ff","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"89efa5dd7c1545c0ad8e16f58fcdfeb6","version":"9c22c5cc997d4b678633ba92b3bb24f1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK003840GWSXLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3126096","datemodified":"2020-12-16T12:39:15","file_list":["cp045572.xml","cpqsetup.exe","M52004G2.rel","payload.json","setup.dll"],"md5sum":"e9844da476b92433dd16a1b2604857e2","name":"cp045572.exe","release":"2020-12-16T12:30:05","revision":"0","sha1sum":"d4213fd7081571e64577a9d164a9b4b296a05a02","size":"2MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"121ced484e6647bf98b3a4bca60530c2","version":"48eb3e78a02b4bb8b09eb8b3d216ac57"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:59:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含適用於 HPE BladeSystem c-Class Virtual Connect 模組的韌體映像。此韌體提供 HPE BladeSystem c-Class Virtual Connect 模組的管理功能。此元件及其韌體可用於下列情況： 1) 搭配 BladeSystem 線上韌體套件中找到的 Smart Update Manager (智慧型更新管理器) 一起使用時，此元件可以用於部署韌體至 HPE BladeSystem c-Class Virtual Connect 模組；及 2) 從此元件解壓縮的韌體可使用 Virtual Connect Support Utility 部署至 HPE BladeSystem c-Class Virtual Connect 模組。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ko","x_late":"이 구성 요소에는 HPE 블레이드시스템 c-클래스 가상 연결 모듈용 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE 블레이드시스템 c-클래스 가상 연결 모듈에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 구성요소는 BladeSystem Online Firmware Bundle에서 확인된 Smart Update Manager와 함께 사용되어 HPE BladeSystem c-Class 가상 연결 모듈로 펌웨어를 배포할 수 있고, 2) HP BladeSystem c-Class 가상 연결 모듈용 가상 연결 지원 유틸리티를 통해 구성요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件可为 HPE BladeSystem c-Class Virtual Connect 模块提供固件镜像。该固件可为 HPE BladeSystem c-Class Virtual Connect 模块提供管理功能。该组件及其固件适用于以下情形： 1) 与在 HP BladeSystem 在线固件包上找到的HP智能升级管理器（Smart Update Manager）配合使用，此组件可用于将固件部署到 HPE C 系列刀片式系统虚拟连接（HP BladeSystem c-Class Virtual Connect）模块；2) 可通过适用于 HPE C 系列刀片式系统虚拟连接模块的虚拟连接支持实用程序（Virtual Connect Support Utility）部署从此组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Virtual Connectモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class Virtual Connectモジュールの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) HPE BladeSystem  c-Class Virtual Connectモジュールにファームウェアをインストールするために、Firmware Maintenance CD上あるいはHPE BladeSystem Online Firmware Bundle内にあるHPE Smart Update Managerと共同でコンポーネントを使用する 。および2) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Virtual ConnectモジュールのVirtual Connectサポートユーティリティを使用してインストールする。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257255528","datemodified":"2020-07-20T02:59:57","file_list":["Entry.bsh","HpsumCli.exe","PackageDesc.xml","cp043332.xml","cp_data.xml","vcfwall485.bin"],"md5sum":"ac1a8acba5c6cd1a98afe0631175fa88","name":"cp043332.exe","release":"2020-07-20T02:44:05","revision":"0","sha1sum":"a058bbcd7e479bf87711be8a579659f09f81a315","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"2720830f9ed94ee48b3be0778488e00f","version":"2d9971b9341e4bd8914f8b99847679ea"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85, HPE VC 8Gb 24-Port FC version&nbsp;4.20, HPE VC 16Gb 24-Port FC version 4.20,&nbsp;and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility&nbsp;release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 &nbsp;and then upgrade from VC 4.50 to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE&nbsp;VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Windows)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition  Component for Windows"},{"lang":"ko","x_late":"Windows용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Windows 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネントfor Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"466482-B21","target_guid":"","type":"other"},{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16593180","datemodified":"2021-01-28T18:28:51","file_list":["/CP044848_BUILD_4.data","/CP044848.vmexe","/CP044848.vmexe64","/CP044848.vmfile","/CP044848_VMw.zip","/CP044848.xml","/payload.json","/CP044848_VMw.zip/index.xml","/CP044848_VMw.zip/vendor-index.xml","/CP044848_VMw.zip/metadata.zip","/CP044848_VMw.zip/vib20/CP044848/HPE_bootbank_CP044848_HPD8.4-7.0.0.15843807.vib","/CP044848_VMw.zip/metadata.zip/vendor-index.xml","/CP044848_VMw.zip/metadata.zip/vmware.xml","/CP044848_VMw.zip/metadata.zip/vibs/CP044848-4593982360690475154.xml","/CP044848_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044848_HPD8.4-7.0.0.15843807.xml"],"md5sum":"96e07df142620b9b58cc0eb0f97ea457","name":"CP044848.zip","release":"2021-01-28T18:25:04","revision":"0","sha1sum":"f658991f6333a9ea7d3d8cfd3419b08ea299f38d","size":"15MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP044848","version":"HPD8.4-7.0.0.15843807"}]}],"id":{"product":"bda7d035201d46ffadf44995b633fe12","version":"604ceea7230e45ff966e6680fd9e2689"},"installation":{"command":"CP042629.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-13T10:52:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11164444","datemodified":"2021-01-28T09:38:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/CP046619.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/U31_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046619.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046619.scexe"],"md5sum":"6040790c84b9a81452c043ab66c12326","name":"firmware-system-u31-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T09:26:24","revision":"0","sha1sum":"53b6c5829988dc8a11ad7ac9e6fd772bd48f67f0","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"f5aa8733027b4498a80cd2e690d91986","version":"2ccec69d930d455195f11af49815020b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10（U31）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.77"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.77"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.77"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.77"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.77.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.77"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.77 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.15.80</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.8.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"22926648","datemodified":"2021-01-20T17:54:11","file_list":["/CP045077_BUILD_7.data","/CP045077.vmexe","/CP045077.vmexe64","/CP045077.vmfile","/CP045077_VMw.zip","/CP045077.xml","/payload.json","/CP045077_VMw.zip/index.xml","/CP045077_VMw.zip/vendor-index.xml","/CP045077_VMw.zip/metadata.zip","/CP045077_VMw.zip/vib20/CP045077/HPE_bootbank_CP045077_1.2.1.7-7.0.0.15843807.vib","/CP045077_VMw.zip/metadata.zip/vendor-index.xml","/CP045077_VMw.zip/metadata.zip/vmware.xml","/CP045077_VMw.zip/metadata.zip/vibs/CP045077--8093202714505397997.xml","/CP045077_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045077_1.2.1.7-7.0.0.15843807.xml"],"md5sum":"06aec6b592b22d0dc1a105a52ee0511b","name":"CP045077.zip","release":"2021-01-20T17:52:07","revision":"0","sha1sum":"2d6c49b0da21a5b3d4cfa1d25d6c4392e7212561","size":"21MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.2.2","vib_list":[{"name":"CP045077","version":"1.2.1.7-7.0.0.15843807"}]}],"id":{"product":"807963ddd98b4f45bbbe57b7d0cec0f8","version":"1710140e6fb04710bf9c19b22f0c9675"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere&nbsp;7.0.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000GWTFEおよびMB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; </strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3036976","datemodified":"2020-12-17T05:11:46","file_list":["cp046335.xml","cpqsetup.exe","payload.json","setup.dll","TAMG07abHPG7.REL"],"md5sum":"67cd0165e692d4b6044947d129c66a1c","name":"cp046335.exe","release":"2020-12-17T05:02:04","revision":"0","sha1sum":"a78db86d73bacbe22374dfea6d14c34bf7f1c313","size":"2MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"3b83490f55194800be58721a957dd6a1","version":"a127e36fc4ac4c7f83604c22b617a9c1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWTFE and MB014000GWTFF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-24T09:52:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware revision improves low-temperature performance and Error Correction Code (ECC) error recording for some commands.&nbsp;</li>\n\t<li>It also improves internal logging capabilities for failure analysis.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5931664","datemodified":"2020-11-04T09:55:49","file_list":["P95_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046160.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"76081a0830640b090be14c73b7705cdc","name":"cp046160.exe","release":"2020-11-04T09:39:06","revision":"0","sha1sum":"626d0f8fd17b56aa369c8b452dfc18d9297df693","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"32d8e1ccf0eb436eb79a5663e0e83dbc","version":"94c2677f40eb4b78994e41e5fe6c466e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML150 Gen9 (P95) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML150 Gen9 (P95)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T06:11:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"}],"sw_keys":[{"name":"P95","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedf, version 2.2.39.0</li>\n\t<li>qedrntv, version 3.40.26.0&nbsp;</li>\n\t<li>qedentv, version 3.40.26.0</li>\n\t<li>qedi, version 2.19.36.0&nbsp;</li>\n</ul>\n"}],"files":[{"bytes":"5182619","datemodified":"2021-01-18T03:29:26","file_list":["/cp044976.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/vib20/qedf/QLC_bootbank_qedf_2.2.39.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/vib20/qedentv/QLC_bootbank_qedentv_3.40.26.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/vib20/qedi/QLC_bootbank_qedi_2.19.36.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.40.26.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vibs/qedf-1026607599207277592.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vibs/qedentv--1044954547408909224.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vibs/qedi-1181774815790339339.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/vibs/qedrntv--2769803270784355947.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807_17317072.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_5.0.245.0-1OEM.700.1.0.15843807.xml"],"md5sum":"ca656fa6ff6c4af52bb58408e6b0e214","name":"cp044976.zip","release":"2021-01-18T03:28:05","revision":"0","sha1sum":"89c3e378364d127e9c35c23edde43ae88b8a8aa3","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qedf","version":"2.2.39.0-1OEM.700.1.0.15843807"},{"name":"qedentv","version":"3.40.26.0-1OEM.700.1.0.15843807"},{"name":"qedi","version":"2.19.36.0-1OEM.700.1.0.15843807"},{"name":"qedrntv","version":"3.40.26.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"70da4993d44e45a79517f24aa5d41862","version":"c84fa45738734ddfa3eb162be86415b2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses a Purple Screen Of Death (PSOD) seen on systems operating in a complicated VLAN environment.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"MRVL-E4-CNA-Driver-Bundle:5.0.245.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qedrntv:3.40.26.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:2.2.39.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.40.26.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedi:2.19.36.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16858258","datemodified":"2021-01-27T11:50:55","file_list":["/CP046386_BUILD_3.data","/CP046386.vmexe","/CP046386.vmexe64","/CP046386.vmfile","/CP046386_VMw.zip","/CP046386.xml","/payload.json","/CP046386_VMw.zip/index.xml","/CP046386_VMw.zip/vendor-index.xml","/CP046386_VMw.zip/metadata.zip","/CP046386_VMw.zip/vib20/CP046386/HPE_bootbank_CP046386_1.27.3-7.0.0.15843807.vib","/CP046386_VMw.zip/metadata.zip/vendor-index.xml","/CP046386_VMw.zip/metadata.zip/vmware.xml","/CP046386_VMw.zip/metadata.zip/vibs/CP046386-1459263755695559488.xml","/CP046386_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046386_1.27.3-7.0.0.15843807.xml"],"md5sum":"a582fc80fae2e7c76ba8669fdfc88e1c","name":"CP046386.zip","release":"2021-01-27T11:35:07","revision":"0","sha1sum":"a91a315dd86fc8ec314aa5b21e13796eede617ef","size":"16MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27","vib_list":[{"name":"CP046386","version":"1.27.3-7.0.0.15843807"}]}],"id":{"product":"aa3d4b3746e2485289f458134b1187cd","version":"e7eec9edd68848238e978ebaedb56512"},"installation":{"command":"CP046386.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":240,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"17000"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-03T13:27:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2016, and Windows Server 2019 for the HPE Smart Storage SR100i Gen10 Plus SW RAID"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1723584","datemodified":"2021-02-25T04:59:00","file_list":["cp045150.xml","cpqsetup.exe","generic.dll","install.xml","smartdq2.cat","SmartDQ2.inf","SmartDQ2.md5","SmartDQ2.sha3-512","SmartDQ2a.sys","SmartDQ2co002.dll","SmartDQ2p.sys","SmartDQ2r.sys"],"md5sum":"4884ddc396e3908ed0ed3aa466313245","name":"cp045150.exe","release":"2021-02-25T04:57:04","revision":"0","sha1sum":"829e646cb3b7c8dd4cd6e16892f6111d191d7b17","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec14b13c05"],"type_of_change":"1","version":"106.106.2.1229"}],"id":{"product":"4a440c014d52404fb26a46463eb5e62b","version":"ad1e5686df41431dbaf3bfc4aa5cbb94"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Storage SR100i Gen10 Plus SW RAID Driver for Windows Server 2016, and Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-25T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"SmartDQ2a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5501840","datemodified":"2020-12-13T13:55:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/CP045435.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/SMKRASD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045435.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045435.scexe"],"md5sum":"d2219c204e3b3baa2b71454130c7494e","name":"firmware-hdd-af802bb412-HPD9-7.1.x86_64.rpm","release":"2020-12-13T13:42:05","revision":"0","sha1sum":"d5308d28249d472017d3ff6ad0749b224e555346","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"c89e43e26231479bbdf6b9f0111deee2","version":"5bc40479d0ab40bbb2b8dafc6630f2f5"},"installation":{"command":"CP040274.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"58edf963-9038-4e01-80c5-59b770e09e25","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"UBM2_V1.16.signed.hex.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"V1.16"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10Plus UBM2 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、ProLiant Gen10Plus UBM2ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"61679","datemodified":"2021-01-29T03:28:22","file_list":["payload.json","UBM2_V1.16.signed.hex.ilo","UBM2_V1.16.xml"],"md5sum":"a338d9af7db156ee6b8764dcbfc61c39","name":"UBM2_V1.16.fwpkg","release":"2021-01-29T03:24:05","revision":"0","sha1sum":"047e70c7289348936e9bed004c080e24469dd35b","size":"60KB","target_guids":["9675b54e-1c96-44c3-a7a1-901502000000"],"type_of_change":"1","version":"1.16"}],"id":{"product":"d36299863db5430ea15927c19344f09a","version":"132ae4e75f9b4be19375b4ebab9121c6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"ファームウェアパッケージ - Gen10Plus UBM2 Backplane PICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-07T16:22:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2PIC","sw_key_expectedpath":"firmware:ubmbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GEQUT and MB8000GEQUU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB6000GEQUTおよびMB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Fixed the issue of Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5555317","datemodified":"2020-12-13T13:56:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/CP045439.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/HAHc8HaoeFGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045439.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045439.scexe"],"md5sum":"c088d6ff3d03156ed7d40e645b763039","name":"firmware-hdd-1d7f19120b-HPGB-8.1.x86_64.rpm","release":"2020-12-13T13:44:05","revision":"0","sha1sum":"d9da6c670f7aede07e9e9d309f7044755a156cda","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"f588f22bf7a8476e978b8ff370066200","version":"9fa6ed3d98504ebc8a11446b70cc8768"},"installation":{"command":"CP040322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was only found during supplier ongoing reliability testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD4"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD4"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>      </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"2984632","datemodified":"2020-12-17T11:58:21","file_list":["cp045506.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXn0HPD4.REL"],"md5sum":"b6fcbbb5da6324f930a43cae1d3f6ddf","name":"cp045506.exe","release":"2020-12-17T11:43:08","revision":"0","sha1sum":"710b94c74aad690d3a3f0ee303c5f9b4736f78ec","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"0a96bc740aee4364b774edfa452ca9a4","version":"ae8bc1ff791b4cf5ab08193439d0bd0b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:34:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n    </strong>Online HDD/SSD Flash Component for Windows (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"2821296","datemodified":"2020-12-16T13:40:03","file_list":["4IDVHPG1.rel","cp045568.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"865395446c858962cdf7e1777edcc08c","name":"cp045568.exe","release":"2020-12-16T13:31:04","revision":"0","sha1sum":"3a70fa6ae5a74bbc08697662e964dfc6287b8249","size":"2MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"ea55ec7473304ea29dd406dfd2137028","version":"7310436a3ecd4eb4b9a304944325a545"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:57:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19226869","datemodified":"2021-02-03T03:26:06","file_list":["/CP045902.vmexe","/CP045902.vmfile","/CP045902_VMw.zip","/CP045902.xml","/payload.json","/README.txt","/CP045902_VMw.zip/index.xml","/CP045902_VMw.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip","/CP045902_VMw.zip/vib20/CP045902/HPE_bootbank_CP045902_1.0.1-6.5.0.4240417.vib","/CP045902_VMw.zip/metadata.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip/vmware.xml","/CP045902_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045902_1.0.1-6.5.0.4240417.xml","/CP045902_VMw.zip/metadata.zip/vibs/CP045902-3689128572757422720.xml"],"md5sum":"7ef2fa5fcdeda7baa7a781a13bc510cb","name":"CP045902.zip","release":"2021-02-03T03:32:05","revision":"0","sha1sum":"a312f7e5a269d8b8936daec7b2d85b25d06893b3","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP045902","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"7a662f7d75e94013936ff11b1e7b1553","version":"5249928f049242e2998a48ccc80bb585"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB8000GFECR Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB8000GFECRドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp; MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL&nbsp;8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5375549","datemodified":"2020-12-13T14:28:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/CP045446.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/SMKRPTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045446.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045446.scexe"],"md5sum":"10e79d12e8ca1f1b9540bacf8953a413","name":"firmware-hdd-6d922fc9a8-HPG6-5.1.x86_64.rpm","release":"2020-12-13T14:16:29","revision":"0","sha1sum":"8b3e526a16205ab248b6ef8843dc05d9b1ca27ac","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"d9c3a00a773f42a180ec8a2979413243","version":"d0be92b56d114be6afe63a6d7181f6e2"},"installation":{"command":"CP040293.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000GFECR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"77706","datemodified":"2021-04-28T10:18:40","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"1942d42f200649a99ef63bd5be62f576","name":"hpsa-kmp-default-3.4.20-188.sles12sp4.x86_64.rpm","release":"2021-04-28T10:01:05","revision":"0","sha1sum":"491822441c5352ca96e2d387368db80d78441887","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-188"},{"bytes":"77188","datemodified":"2021-04-28T10:13:02","file_list":["./lib/modules/4.12.14-115-default","./lib/modules/4.12.14-115-default/updates","./lib/modules/4.12.14-115-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"b829515301080d2fbe9e7b1d1cca305e","name":"hpsa-kmp-default-3.4.20-188.sles12sp5.x86_64.rpm","release":"2021-04-28T10:01:05","revision":"0","sha1sum":"86891b20b8a32efb633c8559fccfb6791d90ce0e","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-188"}],"id":{"product":"fb6a68c03bce4024bbd1868e36b3725e","version":"7851e8b787a940fdb6cd560eb34c87c9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 12 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 12（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-27T05:36:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Add support for SuSE Linux Enterprise Server 12 SP5</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Add support for SuSE Linux Enterprise Server 12 SP5</li>\n\t<li>Added PKCS signing process to fix the secure boot hang issue on Linux SLES12 SP5</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE SNMP 代理程式 (hp-snmp-agents) 彙集了多個以 SNMP 通訊協定為基礎的代理程式及工具，可讓您透過 SNMP 來監控風扇、電源供應器、溫度感應器以及其他管理事件。另外，提供下列項目： 基礎及伺服器代理程式、儲存子系統代理程式、網路子系統代理程式、SNMP 動態載入模組及網路支援應用程式。"},{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ko","x_late":"HPE SNMP 에이전트(hp-snmp-agents)는 SNMP를 통해 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하게 하는 SNMP 프로토콜 기반 에이전트 및 도구 모음입니다. 이 외에도 파운데이션 및 서버 에이전트, 스토리지 하위 시스템 에이전트, 네트워크 하위 시스템 에이전트, SNMP 동적 로드 모듈 및 웹 지원 응용 프로그램 등을 제공합니다."},{"lang":"cn","x_late":"HPE SNMP Agents (hp-snmp-agents) 是一系列基于 SNMP 协议的代理程序和工具，能够通过 SNMP 监控风扇、电源、温度传感器和其他管理事件。它还提供了以下程序： 基础架构和服务器代理程序、存储子系统代理程序、网络子系统代理程序、SNMP 动态加载模块和 Web 支持应用程序。"},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、SNMPプロトコル ベースのエージェント、およびファンの監視、電源、温度センサー、およびその他管理イベントをSNMP経由で行うツールを集めたものです。 また、次の機能も提供します。 基本およびサーバーエージェント、ストレージ サブシステムエージェント、ネットワークサブシステムエージェント、SNMP Dynamically Loaded Module、およびWebサポート アプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"1341087","datemodified":"2021-03-22T15:55:48","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"a9d5e4732ab9148fb716001ef66b3b6c","name":"hp-snmp-agents-10.92-679.11.rhel7.x86_64.rpm","release":"2021-03-22T15:50:05","revision":"0","sha1sum":"a1a0c0a3023aa88615c13bce317cc0fb00df44fc","size":"1MB","target_guids":[],"type_of_change":"1","version":"10.9.2"}],"id":{"product":"067bbc5cffe1421194a0097838afd34e","version":"380c66b326b64a4db9c55f7d0d5b98f3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 伺服器 的 HPE SNMP 代理程式"},{"lang":"en","x_late":"HPE SNMP Agents for Red Hat Enterprise Linux 7 Server"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 서버용 HPE SNMP 에이전트"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 Server版HPE SNMP Agents"},{"lang":"ja","x_late":"HPE SNMPエージェント for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-07T14:17:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Support for Red Hat Enterprise Linux 7.8</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>&nbsp;the hp-snmp-agents service version 10.9.0 on an HPE ProLiant Gen9 Server or an HPE Synergy Gen9 Compute Node may experience a segfault after installation or restart of the hp-snmp-agents service. cmahostd or cmapeerd process will be killed after the segfault.&nbsp; Pleaer review customer advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00098957en_us\" style=\"color:#0563c1; text-decoration:underline\">a00098957en_us</a>&nbsp;for additional details.</li>\n\t<li>The OS version reported by hp-snmp-agents reported a&nbsp;mismatch with the newer Linux OS distros. i.e., &quot;SUSE Linux Enterprise Server 12&quot; v.s &quot;SUSE Linux Enterprise Server 12 SP5&quot;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I24","value":"HP ProLiant BL460c G6 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P62","value":"HP ProLiant DL380 G6 Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5715240","datemodified":"2021-02-08T01:39:25","file_list":["SignedImageInstaller64.dll","U17_2.80_10_16_2020.signed.flash","cp046868.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"109540196c5b17980fb8066c5243dc11","name":"cp046868.exe","release":"2021-02-08T01:22:05","revision":"0","sha1sum":"1b17117f5f45fb51be3f64cc8e2740bd6b553c57","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"07347f7a083340a09fea50459ac770da","version":"04707e4492f243a18faeedbba9273913"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-08T01:18:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the firmware packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4856278","datemodified":"2020-12-13T13:26:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/CP045430.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/TTMRNSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045430.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045430.scexe"],"md5sum":"fba3b5c3b946207644c1a4cc204adf06","name":"firmware-hdd-46fc43ab26-HPD4-7.1.x86_64.rpm","release":"2020-12-13T13:14:04","revision":"0","sha1sum":"d66f1349d0613c58674d26ed9927447086b80ff1","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"a583c05eda574560bf7c625d7e1d2b1c","version":"d3f46218eb43437d93dffbf731905471"},"installation":{"command":"CP040290.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFDSL and MB4000JFDSN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000JVYYV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB6000JVYYV Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17475669","datemodified":"2021-01-28T16:11:43","file_list":["/CP045667_BUILD_4.data","/CP045667.vmexe","/CP045667.vmexe64","/CP045667.vmfile","/CP045667_VMw.zip","/CP045667.xml","/payload.json","/CP045667_VMw.zip/index.xml","/CP045667_VMw.zip/vendor-index.xml","/CP045667_VMw.zip/metadata.zip","/CP045667_VMw.zip/vib20/CP045667/HPE_bootbank_CP045667_HPD2.4-7.0.0.15843807.vib","/CP045667_VMw.zip/metadata.zip/vendor-index.xml","/CP045667_VMw.zip/metadata.zip/vmware.xml","/CP045667_VMw.zip/metadata.zip/vibs/CP045667-8654568973577195964.xml","/CP045667_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045667_HPD2.4-7.0.0.15843807.xml"],"md5sum":"55d2dcee4084221a9207dd659bb80140","name":"CP045667.zip","release":"2021-01-28T16:09:05","revision":"0","sha1sum":"8028d5a0c92d38275fa3aacc2f3f8ef4c6d99a60","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045667","version":"HPD2.4-7.0.0.15843807"}]}],"id":{"product":"ecd26cd8b6e9412ba22bff66e6f6bbbe","version":"4d580246b5014a83a13d919c48383413"},"installation":{"command":"CP040534.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:07:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8691374","datemodified":"2021-03-16T11:46:02","file_list":["/CP047172.vmexe","/CP047172.vmexe64","/CP047172.vmfile","/CP047172.xml","/README.txt"],"md5sum":"6f5ad1cd6a12343df3591255b9c26b2d","name":"CP047172.zip","release":"2021-03-16T16:43:06","revision":"0","sha1sum":"2ee344e4b8d304cbcdbdfdc972bb50137aab758e","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"30164e5ab9734a16a82806757516cba6","version":"42cee8811e034924a99708f0138533c5"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant BL660c Gen9 (I38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant BL660c Gen9（I38）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T16:13:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"I38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_242.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.42"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"33601335","datemodified":"2021-04-06T03:41:44","file_list":["ilo5_242.bin","ilo5_242.xml","payload.json","readme.txt"],"md5sum":"9f572a2460c9885a1fedeac680abc0fb","name":"ilo5_242.fwpkg","release":"2021-04-06T03:38:05","revision":"0","sha1sum":"8355a58601929c4181709e916eaf1d8fc766987c","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"2","version":"2.42"}],"id":{"product":"2dc80c4ae4b943faadb938f8fc2b61d5","version":"6b2d4f89498d49ffa23539d3dacc4619"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"70000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-15T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to import large sized LDAP CA certificate</li>\n\t<li>Support enablement for latest Intel Persistence Memory</li>\n\t<li>iLO GUI to display the Host Operating System Version</li>\n\t<li>Display platform Resiliency and Serviceability (RAS) policy in iLO GUI</li>\n\t<li>Added standard redfish schema support for Computer System &ndash; Reset, Graceful restart actions&nbsp;</li>\n\t<li>Real CPU temperature is reported in addition to normalized temperature (this feature requires ROM 2.40 version)</li>\n\t<li>Support for Active Health System logging by RDE ( Redfish Device Enablement ) enabled devices</li>\n\t<li>Support alerting feature for RDE ( Redfish Device Enablement ) enabled devices&nbsp;</li>\n\t<li>Ability to control LED for locating direct attached SATA drives</li>\n\t<li>Ability to reset power for direct attached SATA drives&nbsp;</li>\n\t<li>Added write protect setting feature for Liquid cooled Delta/Redstone GPU cards.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>iLO 5 reporting incorrect Power Supply count with iLO 5 v2.10</li>\n\t<li>Continuous logging to IML of a CHIF Error running ESXi with iLO 5 v1.46</li>\n\t<li>Random messages &quot;smad[]: No response from iLO for Hello&quot; seen in certain Operating Systems&nbsp;</li>\n\t<li>Incorrect MAC address shown in iLO for Synergy 4820C network adapter</li>\n\t<li>InfiniBand card not syncing with Oneview in iLO 5 v2.30</li>\n\t<li>Copy/paste may not work for more than 255 characters to VSP terminal in Linux platforms&nbsp;</li>\n\t<li>547FLR / 1100Q NIC may reset to default mode after flashing from 1.48 to 2.xx</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>- Added Server Identity (iLO IDevID, iLO LDevID, System IDevID, System IAK and Platform certificates)&nbsp;<br />\n&nbsp; capability to uniquely identify a server across networks that is cryptographically verifiable<br />\n- EAP-TLS based authentication for onboarding into an 802.1X access-controlled network<br />\n- Enabled support for Intel VROC</p>\n\n<ul>\n\t<li>Device discovery and inventory of VROC SATA Controller and drives attached to it</li>\n\t<li>Firmware inventory of Intel VROC(VMD NVMe RAID) and VROC SATA Controller</li>\n</ul>\n\n<p>- Extend size for firmware versions supported to 48 bytes<br />\n- Liquid Cooling support for Apollo systems<br />\n- Server Platform Services Descriptor verification and recovery<br />\n- Enabled Discovery, Inventory and Thermal support for Pensando Cloud Adapters</p>\n\n<ul>\n\t<li>P41849-B21: Pensando DSP DSC-25 Cld-SP 10/25Gb Card</li>\n\t<li>P41852-B21: Pensando DSP DSC-100 Cld-SP 100Gb Card</li>\n</ul>\n\n<p>- For Synergy, restricted the capability to change below settings.</p>\n\n<p>&nbsp; Note : Changes to these settings can affect communication between One-view and iLO</p>\n\n<ul>\n\t<li>iLO Web service&nbsp;</li>\n\t<li>iLO Web service Non-SSL Port</li>\n\t<li>Web server SSL Port</li>\n\t<li>iLO RIBCL Interface</li>\n</ul>\n","curr_fixes_x_late":"<p>- Corrected Product Name listed under Device Inventory as &quot;NVIDIA Quadro M3000SE&quot;, that was wrongly listed as &quot;Synergy 75W MXM Mezzanine&quot; with iLO firmware v2.16 and higher<br />\n- iLO stops monitoring the second Pensando card after the first one fails with a PCIe error<br />\n&nbsp;</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920/e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB012000GWDFE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.&nbsp;</li>\n\t<li>Includes additional fixes to improve error handling and reliability.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18338815","datemodified":"2021-01-28T08:14:43","file_list":["/CP045641_BUILD_6.data","/CP045641.vmexe","/CP045641.vmexe64","/CP045641.vmfile","/CP045641_VMw.zip","/CP045641.xml","/payload.json","/CP045641_VMw.zip/index.xml","/CP045641_VMw.zip/vendor-index.xml","/CP045641_VMw.zip/metadata.zip","/CP045641_VMw.zip/vib20/CP045641/HPE_bootbank_CP045641_HPG2.6-7.0.0.15843807.vib","/CP045641_VMw.zip/metadata.zip/vendor-index.xml","/CP045641_VMw.zip/metadata.zip/vmware.xml","/CP045641_VMw.zip/metadata.zip/vibs/CP045641--2907374327362683235.xml","/CP045641_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045641_HPG2.6-7.0.0.15843807.xml"],"md5sum":"63faaf8716df3e510100e61247ad366d","name":"CP045641.zip","release":"2021-01-28T08:12:07","revision":"0","sha1sum":"821ca9faae66324165c328619580230a303fa69e","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"2","version":"HPG2","vib_list":[{"name":"CP045641","version":"HPG2.6-7.0.0.15843807"}]}],"id":{"product":"6973afa059034a93b5842e17d11d1b46","version":"e3df114577d74e56a5747f7f7f41a0d4"},"installation":{"command":"CP042747.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:42:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing. </li>\n\t<li>Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.</li>\n\t<li>Includes additional fixes to improve error handling and reliability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1139304","datemodified":"2021-01-08T20:42:47","file_list":["cp045117.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt64x64.cat","ixt64x64.din","ixt64x64.inf","ixt64x64.sys","ixtmsg.dll","NicCo36.dll","nicco5.dll","nicdrvr.dll","NicInIXT.dll"],"md5sum":"07b10ed89bec4c7c2fc4046bd3cfb7e5","name":"cp045117.exe","release":"2021-01-08T20:19:04","revision":"0","sha1sum":"23ed63eff8a71ec2134e66a47b252257f6cd5fbe","size":"1MB","target_guids":[],"type_of_change":"0","version":"3.14.214.0"}],"id":{"product":"6f4d825e16414547b68d00b94911e5eb","version":"ea30c16ff7bc4046b0c6318940f901cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Intel ixtドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This driver corrects an issue which results in a link flap with the 1G passthru module.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"}],"sw_keys":[{"name":"ixt64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEQNL and MB6000JEQNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEQNLおよびMB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5527265","datemodified":"2020-12-13T13:55:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/CP045437.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/HAKPSCDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045437.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045437.scexe"],"md5sum":"3a910c2b9c36b51557547d52e77ff860","name":"firmware-hdd-2cfaac41db-HPDB-7.1.x86_64.rpm","release":"2020-12-13T13:42:08","revision":"0","sha1sum":"36a951bd78d6f943179f4f7e0a0017252a344ec6","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"57f299c4757147d2a235078cf35bab3f","version":"6d7ff4cfc466494a9ba7e95068a469c7"},"installation":{"command":"CP040264.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ja","x_late":"HPE SNMPエージェント(hp-snmp-agents)は、ファン、電源、温度センサー、およびその他SNMP経由の管理イベントの監視を可能にするSNMPプロトコルベースのエージェントとツールを集めたものです。同様に、以下を提供します。FoundationおよびServerエージェント、Storage Subsystemエージェント、Network Subsystemエージェント、SNMP動的ロードモジュール、およびWebサポートアプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"1333167","datemodified":"2021-03-23T01:16:54","file_list":["./etc/hp-snmp-agents.conf","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/systemd/scripts/hp-snmp-agents.sh","./usr/lib/systemd/system/hp-snmp-agents.service","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"26378194b2a8fcc5efdd33d90fd1451b","name":"hp-snmp-agents-10.93-680.4.sles15.x86_64.rpm","release":"2021-03-23T01:11:05","revision":"0","sha1sum":"008929eff68a9ff04f68bf98c166d6cf85ce8d02","size":"1MB","target_guids":[],"type_of_change":"1","version":"10.9.3"}],"id":{"product":"f967d142bb1c4216acd867e7f8bae50f","version":"a378825fe66744788c768c47029bc97e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SNMP Agents for SUSE LINUX Enterprise Server 15"},{"lang":"ja","x_late":"HPE SNMPエージェントfor SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-22T16:09:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>&nbsp;the hp-snmp-agents service version 10.9.0 on an HPE ProLiant Gen9 Server or an HPE Synergy Gen9 Compute Node may experience a segfault after installation or restart of the hp-snmp-agents service. cmahostd or cmapeerd process will be killed after the segfault.&nbsp; Pleaer review customer advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00098957en_us\" style=\"color:#0563c1; text-decoration:underline\">a00098957en_us</a>&nbsp;for additional details.</li>\n\t<li>The OS version reported by hp-snmp-agents reported a&nbsp;mismatch with the newer Linux OS distros. i.e., &quot;SUSE Linux Enterprise Server 12&quot; v.s &quot;SUSE Linux Enterprise Server 12 SP5&quot;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.04.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.04.07"},{"DeviceName":"HPE 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3262","Version":"03.82.00"},{"DeviceName":"HPE 82Q 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3263","Version":"03.82.00"},{"DeviceName":"HPE 84Q 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532159000FC","Version":"03.82.00"},{"DeviceName":"HPE SN1000Q 16GB 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E7","Version":"06.04.04"},{"DeviceName":"HPE SN1000Q 16GB 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E8","Version":"06.04.04"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12471866","datemodified":"2021-01-21T15:28:18","file_list":["/CP044781_BUILD_18.data","/CP044781.vmexe","/CP044781.vmexe64","/CP044781.vmfile","/CP044781_VMw.zip","/CP044781.xml","/payload.json","/CP044781_VMw.zip/index.xml","/CP044781_VMw.zip/vendor-index.xml","/CP044781_VMw.zip/metadata.zip","/CP044781_VMw.zip/vib20/CP044781/HPE_bootbank_CP044781_2021.02.01.18-6.7.0.7535516.vib","/CP044781_VMw.zip/metadata.zip/vendor-index.xml","/CP044781_VMw.zip/metadata.zip/vmware.xml","/CP044781_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044781_2021.02.01.18-6.7.0.7535516.xml","/CP044781_VMw.zip/metadata.zip/vibs/CP044781--8478897076719031471.xml"],"md5sum":"e23fb06b2dc5d42efe23798fc715239b","name":"CP044781.zip","release":"2021-01-21T15:25:04","revision":"0","sha1sum":"6cf5d482e59d970d1517279653b9b719776e51dc","size":"11MB","target_guids":["a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4","a6b1a447-382a-5a4f-1077-2532103C3262","a6b1a447-382a-5a4f-1077-2532103C3263","a6b1a447-382a-5a4f-1077-2532159000FC","a6b1a447-382a-5a4f-1077-2031103C17E7","a6b1a447-382a-5a4f-1077-2031103C17E8","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044781","version":"2021.02.01.18-6.7.0.7535516"}]}],"id":{"product":"1c1d2de07cc24b02aa01d9c2dc7eff75","version":"facd5adf8657465c873c7146ed4d249a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.7"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 6.7用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb,&nbsp;16 Gb and 32 Gb&nbsp;products.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>8Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 3.82.00</li>\n\t\t<li>Firmware 8.08.207</li>\n\t\t<li>UEFI 7.00</li>\n\t\t<li>BIOS 3.56</li>\n\t</ul>\n\t</li>\n\t<li>16Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 6.03.00</li>\n\t\t<li>Firmware 8.08.231</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.43</li>\n\t</ul>\n\t</li>\n\t<li>32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;&nbsp;\n\t<ul>\n\t\t<li>Package 02.03.06</li>\n\t\t<li>Firmware 09.04.01</li>\n\t\t<li>UEFI 7.08</li>\n\t\t<li>BIOS 0.0</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices.  \n\n"},{"lang":"cn","x_late":"Smart Storage Administrator (SSA)是一款基于 web 的应用，可帮助您配置、管理、诊断和监控智能阵列管理器，且现在还可支持其他存储设备，如主机总线适配器（HBA）、存储控制器，未来还可支持 SCSI Express 驱动器以及 SAS 交换机设备。  \n\n"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) は、Smartアレイコントローラーや他のストレージデバイス、例えばホストバスアダプター(HBA)、ストレージコントローラーや、SCSI Expressドライブ、SASスイッチデバイスのような将来のデバイスを構成、管理、診断および監視することを助けるWebベースのアプリケーションです。  \n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p>\n\n<p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p>\n\n<p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p>\n\n<p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p>\n\n<p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p>\n\n<p><strong>The following are known issues:</strong></p>\n\n<ul>\n\t<li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li>\n</ul>\n"}],"files":[{"bytes":"9760616","datemodified":"2021-02-15T15:56:03","file_list":["cp041182.xml","cpqsetup.exe","genericmsi.dll","SSA510440_X64.msi"],"md5sum":"0e822364a227b7ede0afad762070cc4c","name":"cp041182.exe","release":"2021-02-15T15:54:05","revision":"0","sha1sum":"a7ac532975a43d69c0873106675863e5577e3a4f","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"type_of_change":"1","version":"5.10.44.0"}],"id":{"product":"594618f566cc4fbca055e8866278e53d","version":"3019aa518f164960b4b42c32cf98e284"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. \n<P>From that drive and directory, execute the downloaded file. \n<P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Windows 64-bit"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives."}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;&nbsp;VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2</p>\n\n<p><br />\n<strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20853851","datemodified":"2021-01-28T21:11:47","file_list":["/CP046658_BUILD_1.data","/CP046658.vmexe","/CP046658.vmexe64","/CP046658.vmfile","/CP046658_VMw.zip","/CP046658.xml","/payload.json","/CP046658_VMw.zip/index.xml","/CP046658_VMw.zip/vendor-index.xml","/CP046658_VMw.zip/metadata.zip","/CP046658_VMw.zip/vib20/CP046658/HPE_bootbank_CP046658_HPK3.1-7.0.0.15843807.vib","/CP046658_VMw.zip/metadata.zip/vendor-index.xml","/CP046658_VMw.zip/metadata.zip/vmware.xml","/CP046658_VMw.zip/metadata.zip/vibs/CP046658-1665042667169241172.xml","/CP046658_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046658_HPK3.1-7.0.0.15843807.xml"],"md5sum":"b6ba46b5098307a23f091390d9b9347e","name":"CP046658.zip","release":"2021-01-28T21:09:05","revision":"0","sha1sum":"afe4ecea3e3495633752307e34b3a80d0b70850e","size":"19MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP046658","version":"HPK3.1-7.0.0.15843807"}]}],"id":{"product":"994a54e899fb4be5bf05bb0bf86539b6","version":"1bf356abfa7e47fab27864dabc3774df"},"installation":{"command":"CP041138.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T18:06:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1762573","datemodified":"2021-01-22T05:08:19","file_list":["./opt/emulex/rhel7/i386/lib/libdfc.so","./opt/emulex/rhel7/i386/lib/libdfc.so.12","./opt/emulex/rhel7/i386/lib/libdfc.so.12.8.316","./opt/emulex/rhel7/i386/lib/libemsdm.so","./opt/emulex/rhel7/i386/lib/libemulexhbaapi.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/rhel7/x86_64/lib64/libemsdm.so","./opt/emulex/rhel7/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.316","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"57eba7d319f2b31f3640fa611ae0b925","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.rhel7.x86_64.rpm","release":"2021-01-22T05:03:41","revision":"0","sha1sum":"52391cc9169bf6b4fc121aa0c607a9fc294540ca","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"86a63f267d0441379f1742c69a628a0a","version":"9e004fd2f5ea46d7aedda966a4fdc9a2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.6.272.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU, and MT1600KEXUV Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUUおよびMT1600KEXUV ドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online NVMe SSD Flash Component for Windows (x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:<br />\n   </strong>  Added support for Windows 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>     </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2866664","datemodified":"2021-04-07T16:27:39","file_list":["4IFDHPK4.rel","cp045592.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"60f6658f72725fbb05095acfcfc49804","name":"cp045592.exe","release":"2021-04-07T16:19:04","revision":"0","sha1sum":"1360e090e6797a9a018042ed4fe6458b0aa7de94","size":"2MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d005de5acf9c47539dbd7a9056630a05","version":"f3a6680b14944d469a11e4e632771b08"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:07:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) device firmware on Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）デバイスファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"2890672","datemodified":"2020-11-12T07:52:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/CP045906.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045906.scexe"],"md5sum":"5c3c1937c3187c46524a9f5c237e963b","name":"firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1.x86_64.rpm","release":"2020-11-12T07:49:07","revision":"0","sha1sum":"d05404b3fa1e19acbcaeb33b2bef7b17802a0e52","size":"2MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.12"}],"id":{"product":"d0d15d83c7a84846a84195d46ef502f4","version":"bd2c2b5bb3894999be9e6352b3ce9436"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於執行 Linux x86_64 平台的 HPE Mellanox VPI (Ethernet 與 Infiniband 模式) 裝置的線上韌體升級公用程式 (Linux x86_64)"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Linux x86_64 platform"},{"lang":"ko","x_late":"Linux x86_64 플랫폼의 HPE Mellanox VPI(이더넷 및 Infiniband 모드) 장치용 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于Linux x86_64平台上的HPE Mellanox VPI（Ethernet和Infiniband模式）设备的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Linux x86_64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Linux x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13520792","datemodified":"2021-01-21T15:25:55","file_list":["cp045037.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80000F91.txt","FW/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","FW/HPE_366FLR_G41713-00x_80001060.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_8000105F.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p10_800027FB.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_80000838.txt","FW/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","FW/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","FW/HPE_562FLR-SFP_DP_H47655-000_80009655.bin","FW/HPE_562FLR-T_B0_AT2_3p10_8000137D.bin","FW/HPE_562SFP_DP_H44490-000_800095AA.bin","FW/HPE_562T_B0_AT2_MCTP_3p10_8000137C.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_5p10_800027FC.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_5p10_800027F8.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1514_P23_NCSI_5p10_800027FA.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_SFX_OCSD_G43260-0xx.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"c7cbb6b4f0591e0f470e663b7dccb9c6","name":"cp045037.exe","release":"2021-01-21T15:17:06","revision":"0","sha1sum":"cd07c5fd752708d24c30b61be686c78e8bfcf2c2","size":"12MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"be56d38accd045cca89d446f2db8440b","version":"419d98ca460242a8ada1795c5f4e87b3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an WOL issue that system wakes up automatically if any magic packet being sent before system was shut down.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Systems Insight Display (SID) modul is green when there&#39;s no Network connection.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18259128","datemodified":"2021-01-27T16:16:46","file_list":["/CP045646_BUILD_4.data","/CP045646.vmexe","/CP045646.vmexe64","/CP045646.vmfile","/CP045646_VMw.zip","/CP045646.xml","/payload.json","/CP045646_VMw.zip/index.xml","/CP045646_VMw.zip/vendor-index.xml","/CP045646_VMw.zip/metadata.zip","/CP045646_VMw.zip/vib20/CP045646/HPE_bootbank_CP045646_HPD2.4-7.0.0.15843807.vib","/CP045646_VMw.zip/metadata.zip/vendor-index.xml","/CP045646_VMw.zip/metadata.zip/vmware.xml","/CP045646_VMw.zip/metadata.zip/vibs/CP045646--1998051310548385785.xml","/CP045646_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045646_HPD2.4-7.0.0.15843807.xml"],"md5sum":"6fca051eb8e4c82bcb5c64610da81b3b","name":"CP045646.zip","release":"2021-01-27T16:14:05","revision":"0","sha1sum":"9f9069169789800673554b0d345b9aea9e033517","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045646","version":"HPD2.4-7.0.0.15843807"}]}],"id":{"product":"809cff8704ac44759685c033bb7b76d3","version":"5892d2443b2c431cb17ca21f254caa82"},"installation":{"command":"CP041451.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for ESXi - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:46:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11386224","datemodified":"2021-01-28T11:52:48","file_list":["cp046647.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_2.42_01_23_2021.signed.flash"],"md5sum":"13bdaa4ced5e5bf9113683e196a63cce","name":"cp046647.exe","release":"2021-01-28T11:50:13","revision":"0","sha1sum":"af2e718beb1bec3e3687c25de0184ca5b184ec9e","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"009bd5d739814a67a018565d835c45f1","version":"01d7582900c84d1b96f4126d064bc284"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML350 Gen10 (U41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:17:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1731097","datemodified":"2021-01-09T00:27:19","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-iavf","./lib/modules/5.3.18-22-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"d12e0d01612ddac46557d5938f1bc163","name":"hp-iavf-kmp-default-4.0.2_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-09T00:11:04","revision":"0","sha1sum":"2e88e871d2691e69f461bb99561c9ca612319bfd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.0.2-1"},{"bytes":"1480992","datemodified":"2021-01-09T00:30:00","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-iavf","./lib/modules/4.12.14-195-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"3237bf9d5f0f685ba24ba657910a15a3","name":"hp-iavf-kmp-default-4.0.2_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-09T00:11:04","revision":"0","sha1sum":"40322f0623c2048d039905f621f15bf566b2fe89","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.0.2-1"}],"id":{"product":"5156ee2ce74d4685bd9c2931c6170220","version":"e441334a8c094af18ed0fa94936d494b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.3.3.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1433296","datemodified":"2020-12-03T19:12:14","file_list":["cp044798.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"f19b3b23562b02eabc880ace92c7c627","name":"cp044798.exe","release":"2020-12-03T19:03:04","revision":"0","sha1sum":"79b3213c5e91eaee11eafb8fc7e396ec6fd860b0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.1.20"}],"id":{"product":"dfa4f5ffa7ed4516ae9ccfcc7a2f5610","version":"17a3ffb1fd7240aab9ba8ce0889e8fdf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Memory dumps were not generated during a crash dump in a boot from SAN environment</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2285488","datemodified":"2021-01-22T07:36:12","file_list":["cp044863.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"f48252f611ceb2c75c2648c452661c8a","name":"cp044863.exe","release":"2021-01-22T07:32:05","revision":"0","sha1sum":"cac83b7f95b16850c7a67eb206ced6a818a48734","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"40030df85c9d48d0a9446bc064913506","version":"9cf4d858a17742ca9574b18c8c279ffe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T08:49:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD5"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR and EG002400JWJNT&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6084088","datemodified":"2020-12-13T08:35:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/CP045381.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/SSKYBT512ED5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD5-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045381.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045381.scexe"],"md5sum":"988314cec2353ee9ec3f5f68c5e57933","name":"firmware-hdd-b1c9eaf74c-HPD5-3.1.x86_64.rpm","release":"2020-12-13T08:23:05","revision":"0","sha1sum":"3150b0de6230c39430f27040e45dde5ff1d8fe0c","size":"5MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"9955e8989d3a49ccb377a1c01a7b8a6c","version":"8b21ac89b6974270b137e988ace5c8fc"},"installation":{"command":"CP041696.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for Linux (x64) - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:34:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.88<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.60(B)</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6880714","datemodified":"2019-08-08T19:26:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/CP039997.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/firmware_signed.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-7.00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039997.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039997.scexe"],"md5sum":"84261221942a6dd6bd6898620f460f56","name":"firmware-smartarray-ea3138d8e8-7.00-1.1.x86_64.rpm","release":"2019-08-08T19:14:12","revision":"0","sha1sum":"39fcda2f19ef37d1e40072c4669a59317419dc1f","size":"6MB","target_guids":[],"type_of_change":"1","version":"7.00"}],"id":{"product":"61f59cb79a694ca78cfec9d06ac2ad97","version":"13095de5299a4e97b38dcb58cb035af0"},"installation":{"command":"CP039997.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP039997.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-ea3138d8e8-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP039997.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-ea3138d8e8-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-ea3138d8e8-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネントfor Linux（x64）- SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-29T18:58:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes the following Issues</p>\n\n<ul>\n\t<li>SATA drive could stop responding&nbsp; while on HBA mode when non-NCQ commands are executed</li>\n\t<li>Controller could stop responding when upgrading due to the DDR Cache Module exceeding its limitations</li>\n\t<li>SSD Cache module could become disable while upgrading FW</li>\n\t<li>Data from the HPE Smart Drive Backplane could potentially become corrupted if a non-HPE carrier is present</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Add optimization for the iLO communication interface in order to have a more effective mechanism to check for ownership of the communication buffer</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Occasionally&nbsp; the drive will not accept any IO&rsquo;s after running Sanitize command for a period of time due to the FW being out of sync with the drive during that time</li>\n\t<li>Non-HPE drives could report &ldquo;Task Set Full&rdquo; due to the drives reaching the qdepth limit during heavy workload</li>\n\t<li>Raid volume is not discovered due to a bad drive consuming two slots during hotplug</li>\n\t<li>Data could become inaccessible when upgrading from&nbsp;firmware versions prior to 4.5x</li>\n\t<li>The controller could stop responding when executing a SCSI verify command due to a CPU exception</li>\n\t<li>The system could stop communicating due to an I/O command timeout</li>\n\t<li>While on HBA mode, a drive could stop responding due to an early allocated buffer release</li>\n\t<li>A SAS drive WWN is reported inaccuratelyy due to an incorrect report causing the driver to be out of sync with the device</li>\n\t<li>If using a 4G module, the controller could stop responding due to the SSD Cache metadata exceeding its limits during a Backup</li>\n\t<li>SSD Smart Cache module become disabled due to a reduction in usable cache space</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWFWKおよびMB002000GWFWLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18099690","datemodified":"2021-01-27T21:22:47","file_list":["/CP045627_BUILD_3.data","/CP045627.vmexe","/CP045627.vmexe64","/CP045627.vmfile","/CP045627_VMw.zip","/CP045627.xml","/payload.json","/CP045627_VMw.zip/index.xml","/CP045627_VMw.zip/vendor-index.xml","/CP045627_VMw.zip/metadata.zip","/CP045627_VMw.zip/vib20/CP045627/HPE_bootbank_CP045627_HPG6.3-7.0.0.15843807.vib","/CP045627_VMw.zip/metadata.zip/vendor-index.xml","/CP045627_VMw.zip/metadata.zip/vmware.xml","/CP045627_VMw.zip/metadata.zip/vibs/CP045627--3302176738636587674.xml","/CP045627_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045627_HPG6.3-7.0.0.15843807.xml"],"md5sum":"6a4e9d3a8ae181e77e3502b675a2dac1","name":"CP045627.zip","release":"2021-01-27T21:20:05","revision":"0","sha1sum":"192487b4fb358a8b5328bc677a970fe07f09bd70","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045627","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"25298d41e8ae4c7a847f78be945ec24d","version":"b3f0ee44d73545adbb43a4d7342c6593"},"installation":{"command":"CP040785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:31:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_2p24_PLDMoMCTP_800059DF.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"2.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td>\n\t\t\t<td>800059DF</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>2.24</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2839.0 includes: Intel(R) Boot Agent ICE v2.2.01 &amp; UEFI x64 100 gigabit driver v2.2.07.</p>\n"}],"files":[{"bytes":"10516337","datemodified":"2021-01-21T10:31:34","file_list":["HPE_E810_XXVDA2_SD_2p24_PLDMoMCTP_800059DF.HPb","HPE_E810_XXVDA2_SD_2p24_PLDMoMCTP_800059DF.xml","payload.json"],"md5sum":"c606f61a335562e6437806684ace7e9a","name":"HPE_E810_XXVDA2_SD_2p24_PLDMoMCTP_800059DF.fwpkg","release":"2021-01-21T10:27:04","revision":"0","sha1sum":"28194a99afccbf8bdde27f21ef561060c34bb5a8","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159b80860003"],"type_of_change":"1","version":"2.24"}],"id":{"product":"0134d053d49b43b1add04e5a51f6ff18","version":"bb1e83128a8e4556889d9489daabe456"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"INTEL_E810_XXV2_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"107723","datemodified":"2021-01-14T07:51:58","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"0da27091401168305cd9b64632d224b2","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"e586b0a32baad96de832d1d4cd60764a48bfac68","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107567","datemodified":"2021-01-14T07:49:25","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"27462c794d5e4f8915ccae7af6fcf256","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"22b22383cfca5ef17ec987ac8a57ef81fa662a22","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"09591d5b70d148ae85b720d091645e6c","version":"e1817901830848a0aea1e2e157a47a7a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.7"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.7上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20083186","datemodified":"2021-02-03T03:39:45","file_list":["/CP045904.vmexe64","/CP045904.vmfile","/CP045904_VMw.zip","/CP045904.xml","/payload.json","/README.txt","/CP045904_VMw.zip/index.xml","/CP045904_VMw.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip","/CP045904_VMw.zip/vib20/CP045904/HPE_bootbank_CP045904_1.0.0-7.0.0.15525992.vib","/CP045904_VMw.zip/metadata.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip/vmware.xml","/CP045904_VMw.zip/metadata.zip/vibs/CP045904--1517099505877222018.xml","/CP045904_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045904_1.0.0-7.0.0.15525992.xml"],"md5sum":"e1a28cdfc099e4a1a327a84a68840576","name":"CP045904.zip","release":"2021-02-03T03:45:05","revision":"0","sha1sum":"ae97d7bab13cb5d0f10c76583ae32cdb3be0b6f7","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045904","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"b208c604a379445cb8f4da716ed6946e","version":"015058df8dd54917b886990bccb64ae3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 7.0"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 7.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package enables auto-nvme connectivity support on Linux Server for HPE Emulex Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8890","datemodified":"2021-01-25T08:13:36","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"088a33487b522976fc38a968e985cf56","name":"nvmefc-connect-12.8.264.0-1.rhel7u9.noarch.rpm","release":"2021-01-25T08:05:04","revision":"0","sha1sum":"8bc23336bfd34c0a9d2ea52fd3cd62a7e26d373d","size":"8KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9cc0c84f"],"type_of_change":"0","version":"12.8.264.0"},{"bytes":"8891","datemodified":"2021-01-25T08:17:10","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"3e3ec795d4dc2dd335f99b73ca8f10a8","name":"nvmefc-connect-12.8.264.0-1.rhel7u8.noarch.rpm","release":"2021-01-25T08:05:04","revision":"0","sha1sum":"d051a857c48c34ee0141a168b50eafc16a4ce665","size":"8KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9cc0c84f"],"type_of_change":"0","version":"12.8.264.0"},{"bytes":"8902","datemodified":"2021-01-25T08:11:40","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"b1f8a6aff295b12b2c205f78f8a3eee8","name":"nvmefc-connect-12.8.264.0-1.sles12sp4.noarch.rpm","release":"2021-01-25T08:05:04","revision":"0","sha1sum":"8ed1967a0b55bb7c0b53c16baeb82a434e106e23","size":"8KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9cc0c84f"],"type_of_change":"0","version":"12.8.264.0"}],"id":{"product":"edfc3fe1db664c19ac762129db3cbadb","version":"4abfb09f812d43539bc2655a0a480cf7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n\n<p>To upgrade the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;# rpm -Uvh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex NVMe Fibre Channel Enablement Kit for HPE Emulex Host Bus Adapters for Linux  Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-18T08:02:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.264.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"106746","datemodified":"2021-01-14T07:43:04","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"723c894499a4e8f2aeeef03e668ae96e","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"272abfb6425aeb7e814dc4e79f20fb672916c16a","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"105101","datemodified":"2021-01-14T07:33:34","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"19be9998bd0254ff12efaf23543c5bab","name":"be2net-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"abc97fbd076566d3857ac3a440d19f580ddf404e","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"c08d6e9a714b4bcab51975dad9f3ab91","version":"bdc3c603bf5c470b8f6dd68a72671f8f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 2</p>\n\n<p>This product now supports elx_net_install.sh&nbsp;installation script to install be2net driver on SUSE Linux Enterprise Server 12 Service Pack 1 or later.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4742944","datemodified":"2020-12-13T08:59:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/CP045397.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/TA13SXD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045397.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045397.scexe"],"md5sum":"a86661f549aea603df6c93995ceb0c2c","name":"firmware-hdd-1cbab97ff0-HPD5-7.1.x86_64.rpm","release":"2020-12-13T08:46:35","revision":"0","sha1sum":"69a909f21bf5b78f75c4dba194586077923ca2a6","size":"4MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8c2e806c31134d5f896832d57e01f96c","version":"b56608aaf90d46d29365913fd7ff466a"},"installation":{"command":"CP040282.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"0.37"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"0.37"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 4200&nbsp;Gen10+ Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Initial Release</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3677128","datemodified":"2021-01-26T16:11:20","file_list":["cp044967.xml","cpqsetup.exe","Eaglescanyon-Release-0.37.bin.fw","payload.json","setup.dll"],"md5sum":"3f72426b3ff2243e1d24fc42337c5755","name":"cp044967.exe","release":"2021-01-26T16:01:17","revision":"0","sha1sum":"32d48e8fbe68d16124be8c4f04d60063fae8e1a2","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"0.37"}],"id":{"product":"b9dda486435f4c78a30de5b1c831c135","version":"066445f8d85d44ecb6263bf017624a40"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T16:05:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"21000926","datemodified":"2021-03-16T04:07:34","file_list":["/CP046982_BUILD_6.data","/CP046982.vmexe","/CP046982.vmexe64","/CP046982.vmfile","/CP046982_VMw.zip","/CP046982.xml","/payload.json","/CP046982_VMw.zip/index.xml","/CP046982_VMw.zip/vendor-index.xml","/CP046982_VMw.zip/metadata.zip","/CP046982_VMw.zip/vib20/CP046982/HPE_bootbank_CP046982_4.13.50.6-7.0.0.15843807.vib","/CP046982_VMw.zip/metadata.zip/vendor-index.xml","/CP046982_VMw.zip/metadata.zip/vmware.xml","/CP046982_VMw.zip/metadata.zip/vibs/CP046982--7629812601403966219.xml","/CP046982_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046982_4.13.50.6-7.0.0.15843807.xml"],"md5sum":"7d3646e2fc0626e80ea1a3afff778fd4","name":"CP046982.zip","release":"2021-03-16T04:04:09","revision":"0","sha1sum":"92d9f8d466a87afc67f7e0d00ff43c69cdb15c78","size":"20MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"0","version":"4.13.50","vib_list":[{"name":"CP046982","version":"4.13.50.6-7.0.0.15843807"}]}],"id":{"product":"f68792033b364ab4b274dc849cf93dea","version":"1f7a14b7d04142f0b04ecb9c031caae8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE QLogic FastLinQ 上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE QLogic FastLinQ 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware 版 HPE QLogic FastLinQ 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-02T06:35:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel mezzanine host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9322995","datemodified":"2020-11-25T08:21:22","file_list":["/CP044795_BUILD_7.data","/CP044795.vmexe","/CP044795.vmexe64","/CP044795.vmfile","/CP044795_VMw.zip","/CP044795.xml","/payload.json","/CP044795_VMw.zip/index.xml","/CP044795_VMw.zip/vendor-index.xml","/CP044795_VMw.zip/metadata.zip","/CP044795_VMw.zip/vib20/CP044795/HPE_bootbank_CP044795_2021.02.01.7-7.0.0.15843807.vib","/CP044795_VMw.zip/metadata.zip/vendor-index.xml","/CP044795_VMw.zip/metadata.zip/vmware.xml","/CP044795_VMw.zip/metadata.zip/vibs/CP044795--7004467728433071734.xml","/CP044795_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044795_2021.02.01.7-7.0.0.15843807.xml"],"md5sum":"af61a0a28872269f0694535d9c62a992","name":"CP044795.zip","release":"2020-11-25T08:17:05","revision":"0","sha1sum":"26137d14beb7c768aedc72198efefb14e840ba93","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044795","version":"2021.02.01.7-7.0.0.15843807"}]}],"id":{"product":"4168bdd100e94b7997ab17226da297b5","version":"eccf0822da0e4814874cadd59a619712"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Mezzanine Host Bus Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb and 16 Gb&nbsp;products.</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td style=\"width:50px\">UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.03.00</td>\n\t\t\t<td>8.08.231</td>\n\t\t\t<td>7.02</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Address unexpected behavior when Fibre Channel adapters were simultaneously running traffic to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n\t<li>Fibre Channel adapter firmware versions were not showing up as expected in the AHS log.</li>\n\t<li>Port statistics counters would sometimes not update in the event of Loss of Signal or Loss of Sync</li>\n\t<li>link downs would occur during specific frame sequences used by the HPE XP8 array after array-side link loss</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB010000GWAYN and MB008000GWAYL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB010000GWAYNおよびMB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4168392","datemodified":"2020-12-17T05:33:52","file_list":["cp045527.xml","cpqsetup.exe","HLIBRHHaseFG5.rel","payload.json","setup.dll"],"md5sum":"dc5b81018203f08ca00250c6000ceb8a","name":"cp045527.exe","release":"2020-12-17T05:23:05","revision":"0","sha1sum":"da3562cacf82f97ada009809649b65ce955626ef","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"70cd98996b234f1990b49a33858ae471","version":"72e53b95725f4784b2b79f0e2cf85b01"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:41:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing. </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.Â </li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 MCX653435A-HDAI OCP3 PCIe4 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16&nbsp; OCP3 MCX653435A-HDAI Adapter(P31323-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000592</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5524695","datemodified":"2021-02-25T13:35:25","file_list":["20_29_1016-MCX653435A-HDA_HPE_Ax.pldm.signed","20_29_1016-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"4e3ea4bb17dbece08a4d3f0f51de7720","name":"20_29_1016-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:32:05","revision":"0","sha1sum":"9db3abdbcb0919baedb3d2080dd631f0ad065818","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900347"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"e6fc00ad6a3e4c539778e7419a9fafa6","version":"0e4aff80593f446a8b1e0790214b369a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 MCX653435A-HDAI OCP3 PCIe4 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-05T17:09:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "},{"lang":"ja","x_late":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"62472366","datemodified":"2021-02-02T15:09:50","file_list":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/3_04210_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_BGSanitize.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Change Drive Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure21-EnableTheUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Manage PCIe Storage Interface.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Mark Drive Offline.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Replace_Missing_Drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_background_operations.svg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_mail_server.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398236.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398345.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398429.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398469.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12698838.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13057592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13100187.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13111710.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13365465.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895285.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/63C2E45CB45A465C8D53407524D7E5FF.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/948B09F082BDCBF81D5496A19E5890D4.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/EC76858D51A9C92959EC3735825CC13D.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/6AB35D2EB42441B41AAFB1934F9B98A3.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/8D40259B8CE49463AE3836D3BA7B9EBE.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/B5CD183A7E8F7863A4E5B17D5C17B05A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/47BB223EF06F049BC828364D0CC73B1E.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6227901A46DE11E7368CF1D7021032AA.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/795F47DD716BB083A21DD72E7DCDA43A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/A33E682D8A44A8CC61711FE2D80B1DEC.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/0036BF84BBF761FA5A817B2AB5000709.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6EB4A93ACDD7659C40D6962BD4D66C32.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/89B92DC2898CEBCFD6E2C40ECDFD08FA.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/4826457BD7CBF50AFF02086731A9DED2.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/BFE9E66A49029BC46374B3D428E0831F.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/F90D9EFECF4C09C65F4037B0DDE10FD5.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"md5sum":"3b538933ad34cce96ed81b681069d8c6","name":"MRStorageAdministrator-007.016.016.000-00.x86_64.rpm","release":"2021-02-02T15:04:04","revision":"0","sha1sum":"8a7fbf873bcadd8cbcd2f1ab542251c33d4adf9c","size":"59MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"type_of_change":"0","version":"7.016.16.0"}],"id":{"product":"c697574afe4243919c63d77cce675260","version":"5ff02e6335e649ee8ebc17d9d057f666"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;rpm_name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator (HPE MRSA) for Linux 64-bit"},{"lang":"ja","x_late":"Linux 64-bit用HPE MegaRAID Storage Administrator (HPE MRSA)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-05T12:19:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Release</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Gen10+ MegaRAID Controllers.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MRStorageAdministrator","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_1.0.7s.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.7"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"150284","datemodified":"2021-02-02T15:17:28","file_list":["payload.json","PICGen10-1.0.7-1.xml","PICGen10_1.0.7s.hex"],"md5sum":"d9a468c9f28049f907d7c757da25a9c8","name":"PICGen10-1.0.7-1.fwpkg","release":"2021-02-02T15:14:08","revision":"0","sha1sum":"ec95a156fee096c5a1ee7e7715201d4e11b719aa","size":"146KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.7"}],"id":{"product":"fae7c963a551489594d913b81c29f2a4","version":"5ea6b6a68f2c4dda9aee82ef6c7ab252"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong>（SPP）ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュパッケージ - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-02T03:07:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (C) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (C) if a previous component revision was used to upgrade the firmware to ver. 1.0.7. This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p>Added support for VMware ESXi 7.x on AMD Gen10 and Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (D) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (D) if a previous component revision was used to upgrade the firmware to ver. 1.0.7. This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p>Added support for VMware ESXi 7.x on AMD Gen10 and Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD3"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントはドライブモデル：EG000600JWFUVおよびEG001200JWFVA のファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2908392","datemodified":"2020-12-17T13:48:02","file_list":["cp045491.xml","cpqsetup.exe","payload.json","setup.dll","T14SELD3.REL"],"md5sum":"315c9b834127498051cd0190d1fff681","name":"cp045491.exe","release":"2020-12-17T13:39:10","revision":"0","sha1sum":"c166163afd003233c634856b71ec82aa30b72ef0","size":"2MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"0","version":"HPD3"}],"id":{"product":"62c5be0602154ae6afbf730b5a1cb394","version":"5fdf7ff86d1e43c99731e639564cb828"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:29:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.00(C)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>VMware vSphere 6.7 OSのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点：</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"11528580","datemodified":"2018-09-25T14:26:34","file_list":["/CP037611.vmexe","/CP037611.vmfile","/CP037611.xml","/payload.json","/README.txt"],"md5sum":"c550122373e1a49be92c518768904b3d","name":"CP037611.zip","release":"2018-10-23T00:00:00","revision":"1","sha1sum":"0de2f549fd62b8bbf2572e0ba4d9919ec9a86b03","size":"10MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00","vib_list":[]}],"id":{"product":"c1bd991a7a664214ab29388b7b63a963","version":"f7c5708b9400487cbac2b9b942488a5f"},"installation":{"command":"CP037611.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 8.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-04T14:11:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15955413","datemodified":"2021-01-28T09:46:57","file_list":["/CP045676_BUILD_5.data","/CP045676.vmexe","/CP045676.vmexe64","/CP045676.vmfile","/CP045676_VMw.zip","/CP045676.xml","/payload.json","/CP045676_VMw.zip/index.xml","/CP045676_VMw.zip/vendor-index.xml","/CP045676_VMw.zip/metadata.zip","/CP045676_VMw.zip/vib20/CP045676/HPE_bootbank_CP045676_HPD5.5-7.0.0.15843807.vib","/CP045676_VMw.zip/metadata.zip/vendor-index.xml","/CP045676_VMw.zip/metadata.zip/vmware.xml","/CP045676_VMw.zip/metadata.zip/vibs/CP045676--3738088221431462872.xml","/CP045676_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045676_HPD5.5-7.0.0.15843807.xml"],"md5sum":"7f65e8eee9ea77ba86e404ea8ab3ffe1","name":"CP045676.zip","release":"2021-01-28T09:44:06","revision":"0","sha1sum":"dc09cda7e10c43b607eec6c3c9409784e7d0fdc1","size":"15MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP045676","version":"HPD5.5-7.0.0.15843807"}]}],"id":{"product":"1d291170bb0944cd8d58e9257151b0f1","version":"1ca881a856d34b76ba8844d131eb4a1b"},"installation":{"command":"CP041422.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:15:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000GWKGRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6109432","datemodified":"2020-12-13T09:24:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/CP045412.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045412.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045412.scexe"],"md5sum":"d52c381ea739c6b1b921d35c6eb1c048","name":"firmware-hdd-7f2a26e6d0-HPG1-4.1.x86_64.rpm","release":"2020-12-13T09:11:08","revision":"0","sha1sum":"5a701da2ecaf7d06432b370e9282e83bad64819f","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d33174a587ab4b3ea4d5e4e22de786d1","version":"cde6f86cc9f541eea24deb6d37680074"},"installation":{"command":"CP041521.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6923115","datemodified":"2021-03-08T18:39:51","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"32bc2ce6aedf0ac2a826f391faccd574","name":"kmod-netxtreme2_bl-7.14.76-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:16:05","revision":"0","sha1sum":"9693561a7d07a875980a98cd96e332d8b4e56d6d","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"6925363","datemodified":"2021-03-08T18:43:03","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"38271ffc3f2fe8948b077bd57cb878a4","name":"kmod-netxtreme2_bl-7.14.76-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:16:05","revision":"0","sha1sum":"754a1e8e7f37936ac8321a700d4888cd337963e4","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"690ed2c76a80449da0cbf178bbdf3cd5","version":"90b701c5b1854b38b389070c71929094"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers correct an issue where iSCSI target discovery fails to complete when booting from SAN or a local HD.</p>\n\n<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK0960GECQK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15527654","datemodified":"2021-01-28T16:38:42","file_list":["/CP045671_BUILD_3.data","/CP045671.vmexe","/CP045671.vmexe64","/CP045671.vmfile","/CP045671_VMw.zip","/CP045671.xml","/payload.json","/CP045671_VMw.zip/index.xml","/CP045671_VMw.zip/vendor-index.xml","/CP045671_VMw.zip/metadata.zip","/CP045671_VMw.zip/vib20/CP045671/HPE_bootbank_CP045671_HPG3.3-7.0.0.15843807.vib","/CP045671_VMw.zip/metadata.zip/vendor-index.xml","/CP045671_VMw.zip/metadata.zip/vmware.xml","/CP045671_VMw.zip/metadata.zip/vibs/CP045671-3416186413637765880.xml","/CP045671_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045671_HPG3.3-7.0.0.15843807.xml"],"md5sum":"a655682aa01d117326ac6ca2c71f6310","name":"CP045671.zip","release":"2021-01-28T16:36:04","revision":"0","sha1sum":"426805dedd38b19b546ac030f01f9ce525c1b6c2","size":"14MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3","vib_list":[{"name":"CP045671","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"fbb06cc4248449e08cfdf0ed7c07c5e1","version":"c3bd2ddda8974abeb9ccc98ffbd1cf68"},"installation":{"command":"CP042541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:10:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"76675","datemodified":"2020-06-29T09:39:43","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"05bf3283e7f9e24eb03d8fcd0dc684ee","name":"hpsa-kmp-default-3.4.20-197.sles15sp1.x86_64.rpm","release":"2020-06-29T09:30:04","revision":"0","sha1sum":"23e7c76e7fddef076dcad0290b2cae1a4c436bc3","size":"74KB","target_guids":[],"type_of_change":"1","version":"3.4.20-197"},{"bytes":"76223","datemodified":"2020-06-29T09:38:15","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hpsa.ko","./usr/share/smartupdate/hpsa-kmp-default/component.xml"],"md5sum":"07b342a4e31de5101a11e76c4ffaf26d","name":"hpsa-kmp-default-3.4.20-197.sles15sp2.x86_64.rpm","release":"2020-06-29T09:30:04","revision":"0","sha1sum":"c3a168adb79df02394cb8c70b2e36bcd75d4b465","size":"74KB","target_guids":[],"type_of_change":"1","version":"3.4.20-197"}],"id":{"product":"4f235836a2c34b2fb5610223cd1b694c","version":"14254ac5d34d468d8c0b7864fcb20f05"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注記：</strong>インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e hpsa-kmp-default-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 15(64-bit)用HPE ProLiant Smartアレイコントローラー(64-bit)ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-27T22:13:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for SUSE Linux Enterprise Services15 SP1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Support for SUSE Linux Enterprise Service 15.2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV, and VO3840JFDHA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VO0480JFDGT、VO0960JFDGU、VO1920JFDGVおよびVO3840JFDHAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV&nbsp;and VO3840JFDHA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp;</strong> &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5033473","datemodified":"2020-12-13T16:26:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/CP045479.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/GP1633D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045479.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045479.scexe"],"md5sum":"56955349b4d9e422367d63cabb648f19","name":"firmware-hdd-8ed8893abd-HPD9-3.1.x86_64.rpm","release":"2020-12-13T16:14:04","revision":"0","sha1sum":"67ba2b3117cc72a2815babdc4500301b7b983f8d","size":"4MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"13652737a6ea4ec4a4913fd807c0a85c","version":"6ed0efa36bef4611a824cc29ad9f9e36"},"installation":{"command":"CP042220.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:20:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD8"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17838788","datemodified":"2021-01-27T16:23:47","file_list":["/CP046300_BUILD_2.data","/CP046300.vmexe","/CP046300.vmexe64","/CP046300.vmfile","/CP046300_VMw.zip","/CP046300.xml","/payload.json","/CP046300_VMw.zip/index.xml","/CP046300_VMw.zip/vendor-index.xml","/CP046300_VMw.zip/metadata.zip","/CP046300_VMw.zip/vib20/CP046300/HPE_bootbank_CP046300_HPD8.2-7.0.0.15843807.vib","/CP046300_VMw.zip/metadata.zip/vendor-index.xml","/CP046300_VMw.zip/metadata.zip/vmware.xml","/CP046300_VMw.zip/metadata.zip/vibs/CP046300-4817277124301542065.xml","/CP046300_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046300_HPD8.2-7.0.0.15843807.xml"],"md5sum":"0fc6b7a81de62f404f0adf2bc9016cf2","name":"CP046300.zip","release":"2021-01-27T16:21:04","revision":"0","sha1sum":"19731f15b3b80e4c8d663d6b5b58a92e569eef62","size":"17MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP046300","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"ec5fd859b967489ab6f67ad677712984","version":"f3659de9604b42298c5b5a35bd9d799b"},"installation":{"command":"CP040536.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-19T12:30:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB2000GCWLT, MB3000GCWLU, and MB4000GCWLV Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5156102","datemodified":"2020-12-13T13:24:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/CP045429.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/HMKPB6G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045429.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045429.scexe"],"md5sum":"58003e6dc5eb646e588beb1b35de2f05","name":"firmware-hdd-2e70ce7412-HPG4-9.1.x86_64.rpm","release":"2020-12-13T13:12:09","revision":"0","sha1sum":"e702e52736cab5c61d3ed91b0cb5880cd25ecb7a","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"75970c81b36f443fbbff409af0bea2a1","version":"3e759217e0774b618e735d5c2a45f595"},"installation":{"command":"CP040289.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD7"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD7"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD7"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD7"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD7"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD7"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD7"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD7"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD7"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD7"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD7"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD7"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD7"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2967504","datemodified":"2020-11-12T16:14:41","file_list":["cp045576.xml","cpqsetup.exe","payload.json","setup.dll","TAPM5ALLHPD7.rel"],"md5sum":"b94844c6f19a2f14a9bb9860d4e37a8c","name":"cp045576.exe","release":"2020-11-12T16:05:26","revision":"0","sha1sum":"1d9a01c6bda608995288930ea5fb6f2557f4eff8","size":"2MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"9141b4ee76c74b70a4eb2f021bfa217f","version":"0e62221aeaef40c98fa8ba0904b0a6ea"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:00:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 8下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"24783","datemodified":"2020-07-06T11:57:10","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/cb","./usr/lib/.build-id/cb/5bec14136f3825b1d2762937b771a8742b8685","./usr/lib64/libbnxt_re-216.0.88.3.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"ede078b078d2585ea5ef5952dd8261e4","name":"libbnxt_re-216.0.88.3-rhel8u0.x86_64.rpm","release":"2020-07-06T11:55:04","revision":"0","sha1sum":"b690bd8ce807292354af4f26a0f8deff5bea3030","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"216.0.88.3"}],"id":{"product":"78fdd206c60e4542b98f133555e58070","version":"6b70ef236ccf41b09c0dea4ba1fb2d63"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E RoCEライブラリ for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now disables loading RoCE driver on VFs when Link Aggregation is enabled</li>\n\t<li>This product now supports rdma-core v22&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13221591","datemodified":"2021-01-26T22:21:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/CP046669.xml","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/I41_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046669.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046669.scexe"],"md5sum":"a8acc39094332a320c008e996f69bf3b","name":"firmware-system-i41-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-26T22:13:05","revision":"0","sha1sum":"57117f21803902d1d70a2f9945e11e0579f19316","size":"12MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"0da1225b30784f8690bf763f9cc09498","version":"69035a420f894c64b4387ccd55aafc1b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL460c Gen10 (I41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant BL460c Gen10 (I41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T22:27:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18789659","datemodified":"2021-01-27T16:22:56","file_list":["/CP045647_BUILD_3.data","/CP045647.vmexe","/CP045647.vmexe64","/CP045647.vmfile","/CP045647_VMw.zip","/CP045647.xml","/payload.json","/CP045647_VMw.zip/index.xml","/CP045647_VMw.zip/vendor-index.xml","/CP045647_VMw.zip/metadata.zip","/CP045647_VMw.zip/vib20/CP045647/HPE_bootbank_CP045647_HPD2.3-7.0.0.15843807.vib","/CP045647_VMw.zip/metadata.zip/vendor-index.xml","/CP045647_VMw.zip/metadata.zip/vmware.xml","/CP045647_VMw.zip/metadata.zip/vibs/CP045647--2676056250798928325.xml","/CP045647_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045647_HPD2.3-7.0.0.15843807.xml"],"md5sum":"a1f924099f2d3cfa19f2eafe7519d6cc","name":"CP045647.zip","release":"2021-01-27T16:20:05","revision":"0","sha1sum":"b05816f5cbb588d8896847c2f062cbe0038bc59b","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045647","version":"HPD2.3-7.0.0.15843807"}]}],"id":{"product":"a2bc84f793fd4972b6196baf3df85eb6","version":"16ec643c9cec47898d4ea4bfcb10b7ca"},"installation":{"command":"CP041510.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWUDB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:47:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8736021","datemodified":"2020-11-03T21:11:42","file_list":["/CP046142.vmexe","/CP046142.vmexe64","/CP046142.vmfile","/CP046142.xml","/README.txt"],"md5sum":"cf94cdfbcb4d0cd9fc1ddaae4e96d867","name":"CP046142.zip","release":"2020-11-04T03:09:04","revision":"0","sha1sum":"dee10940e2744e80ae3d77f93bc47ce0a41d549d","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"2d670e4a587b4b0daab7ed709579acb1","version":"c101ff3dbf7d4311aa9101280a6f3a26"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL120 Gen9（P86）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T02:32:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Ver. 2.76_10-21-2019 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.76_10-21-2019.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.76_10-21-2019.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-0151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD7"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD7"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models:EG0600JETKA, EG0900JETKB and EG1200JETKC"},{"lang":"ja","x_late":"このSmartコンポーネントは、ドライブモデルEG0600JETKA、EG0900JETKB、およびEG1200JETKCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15900434","datemodified":"2021-01-27T13:26:01","file_list":["/CP045612_BUILD_3.data","/CP045612.vmexe","/CP045612.vmexe64","/CP045612.vmfile","/CP045612_VMw.zip","/CP045612.xml","/payload.json","/CP045612_VMw.zip/index.xml","/CP045612_VMw.zip/vendor-index.xml","/CP045612_VMw.zip/metadata.zip","/CP045612_VMw.zip/vib20/CP045612/HPE_bootbank_CP045612_HPD7.3-7.0.0.15843807.vib","/CP045612_VMw.zip/metadata.zip/vendor-index.xml","/CP045612_VMw.zip/metadata.zip/vmware.xml","/CP045612_VMw.zip/metadata.zip/vibs/CP045612-1462059810884858018.xml","/CP045612_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045612_HPD7.3-7.0.0.15843807.xml"],"md5sum":"c14fa3e26596f80f571fb039abacbf05","name":"CP045612.zip","release":"2021-01-27T13:23:05","revision":"0","sha1sum":"609c0b484b5bf2cd6bed20f1a19792d831cb6c96","size":"15MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP045612","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"d5fee9f753d04f3ba9583fdfe0002842","version":"e0586f2f71b64c14a2e61ad4373c3019"},"installation":{"command":"CP040504.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG0600JETKA、EG0900JETKB、およびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:17:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"358890","datemodified":"2020-02-05T16:23:11","file_list":["/cp042919.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"073093bafe630e1dc71c1395a11fe424","name":"cp042919.zip","release":"2020-02-05T22:23:05","revision":"0","sha1sum":"9d045e2340350da0b9dd8e812c582e52a8c4108a","size":"350KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"4af400bbe27947109ef9222bacd0d2fd","version":"51edc3e8ce5e4b15a197316085ddafe6"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000GWKGRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>     </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4279376","datemodified":"2020-12-17T06:11:13","file_list":["cp045523.xml","cpqsetup.exe","HVLAeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"3845e2bfe9eb4bd370bbbc7402d53035","name":"cp045523.exe","release":"2020-12-17T05:58:13","revision":"0","sha1sum":"e9b1319e2ec2f1e4b1dad0cf79964e8725f14103","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"4fd1e8e4a27347cd8d83d1e63d9eb38e","version":"a826a84bd01240d4b274abf85946e3f0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:40:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen9 NVMe storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen9 NVMe ストレージバックプレーンのファームウェアをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"539776","datemodified":"2018-10-02T23:19:46","file_list":["cp037743.xml","cpqsetup.exe","cpqsysio64.sys","NVMe_BP_flashV8B4_signed.hex","SignedImageInstaller64.dll"],"md5sum":"244576e349e2d5fe1e0a57d00a25cb56","name":"cp037743.exe","release":"2018-10-03T04:19:03","revision":"0","sha1sum":"379198028e2db0041b12f2662376e86cadf36f46","size":"527KB","target_guids":[],"type_of_change":"0","version":"8.4"}],"id":{"product":"eb945575db8f48b5a4d14fa2a05d3f58","version":"4368d6a7a48c448c8f9f6e94a7795a41"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a><strong>:</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - NVMe Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネント for Windows x64 - NVMeバックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-29T17:41:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Resolved an information disclosure vulnerability issue; ref: CVE-2017-8992</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Note:</strong>&nbsp;If&nbsp;version 8.4 was previously installed, then it is not necessary to upgrade to version 8.4 (D).</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"NVMePIC-Gen9","sw_key_expectedpath":"firmware:sd:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 6.5. "},{"lang":"ja","x_late":"このパッケージには、ESXi 6.5上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート548SFP+アダプター（P11338-B21）</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15745245","datemodified":"2021-02-03T06:59:00","file_list":["/CP045197.vmexe","/CP045197.vmfile","/CP045197_VMw.zip","/CP045197.xml","/payload.json","/README.txt","/CP045197_VMw.zip/index.xml","/CP045197_VMw.zip/vendor-index.xml","/CP045197_VMw.zip/metadata.zip","/CP045197_VMw.zip/vib20/CP045197/HPE_bootbank_CP045197_1.0.1-6.5.0.4240417.vib","/CP045197_VMw.zip/metadata.zip/vendor-index.xml","/CP045197_VMw.zip/metadata.zip/vmware.xml","/CP045197_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045197_1.0.1-6.5.0.4240417.xml","/CP045197_VMw.zip/metadata.zip/vibs/CP045197-9142862686628790582.xml"],"md5sum":"066aed54aeed8c1fda2bac9f316f4825","name":"CP045197.zip","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"569054bad0a4e53b6b746ac08fa7dc93785cffad","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.4","vib_list":[{"name":"CP045197","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"d4fc4da3121749de965df405cffc318e","version":"fef7db202a014e2da3d785db5c7b58f0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 6.5）"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T20:24:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.28.xxxx:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.28.xxxx:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:<br />\n&nbsp;&nbsp;&nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p><strong>Known Issues(refer to Customer Bulletin for workarounds):</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5381336","datemodified":"2021-01-25T06:43:19","file_list":["cp046660.xml","cpqsetup.exe","GP1723b0HPK3.rel","payload.json","setup.dll"],"md5sum":"ac01b78bbc891673f482bc344622a0e0","name":"cp046660.exe","release":"2021-01-25T06:32:09","revision":"0","sha1sum":"b7a0fd266d4f525d5549c592c56da71fef332e4f","size":"5MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"8ffd589c0d3c4586b8af1c72d7c3699f","version":"1824ac7d10e9455caccab3153f92fd2f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T18:31:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Marvell FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2016とWindows Server 2019で動作するMarvell  FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3150464","datemodified":"2021-01-21T06:51:03","file_list":["cp044971.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_ah_mbi_open_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"85bb2267281ce4c9f04cad1d46f60380","name":"cp044971.exe","release":"2021-01-21T06:38:04","revision":"0","sha1sum":"40e7c8e7a6b152dbee4d1a84633cfea4fc2b3de1","size":"3MB","target_guids":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"28492eec99964c7884a778af5a393aa1","version":"c924ae49269f4d53b93dbb5ac5a0603c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Marvell FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"Marvell FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue of inconsistent LED behavior while linking up with different speed.</li>\n\t<li>This product corrects an issue about failing to restore the factory default value by pressing F7.</li>\n\t<li>This product addresses an issue where driver doesn&rsquo;t load upon booting up by correct memory relocation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supported NPAR enabling option.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product contains support PLDM firmware upgrade base improvements.</li>\n\t<li>This product addresses an overheat issue on the network adapters as below,</li>\n</ul>\n\n<p style=\"margin-left:80px\">HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter<br />\nHPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_MARVELL_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Channel Interface Driver allows software to communicate with the iLO 4 management controller.  The driver is used by the ProLiant Health Monitor, Insight Management Agents and WBEM Providers, Agentless Management Service, and other utilities."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"616376","datemodified":"2019-07-19T13:44:47","file_list":["cp039985.xml","CpqCi.dll","cpqsetup.exe","cpqsmif.dll","generic.dll","hpqilo3chif.sys","hpqilo3chif2016.cat","hpqilo3chif2016.inf","install.xml"],"md5sum":"18b932b5ca66e3992f94fae9ec3e9d5e","name":"cp039985.exe","release":"2019-07-19T13:43:05","revision":"0","sha1sum":"0dde40b96982bdf38b6951632958856a8b3514f6","size":"601KB","target_guids":[],"type_of_change":"0","version":"4.1.0.0"}],"id":{"product":"cef186d7aeff4c8eb2518a5d81c00613","version":"58284ae214af415c9547f8c8ddca851f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Channel Interface Driver for Windows Server 2016 and Server 2019"},{"lang":"ja","x_late":"iLO 4チャネルインターフェースドライバー for Windows Server 2016 および Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Corrected a potential Windows bugcheck 0x50 (PAGE_FAULT_IN_NONPAGED_AREA) that could occur if Windows restarts the driver without unloading it.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpqilo3chif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"系統管理首頁針對單一伺服器管理提供一個統整且緊密的整合管理功能，包括效能、故障、安全性、診斷、組態及軟體變更管理。"},{"lang":"en","x_late":"The System Management Homepage provides a consolidated view for single server management highlighting tightly integrated management functionalities including performance, fault, security, diagnostic, configuration, and software change management."},{"lang":"ko","x_late":"시스템 관리 홈 페이지는 성능, 고장, 진단, 구성 및 소프트웨어 변경 관리를 포함한 통합 관리 기능을 강조한 단일 서버 관리용 통합 뷰를 제공합니다."},{"lang":"cn","x_late":"通过 System Management Homepage，可以统一查看单个服务器管理，特别是综合管理功能，包括性能、故障、安全性、诊断、配置及软件更改管理。"},{"lang":"ja","x_late":"System Management Homepageは、パフォーマンス、障害、セキュリティ、診断、コンフィギュレーション、およびソフトウェアの変更管理を含む統合された管理機能をハイライトする、シングル サーバー管理のための集約した画面を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>As per SMH EOL terms, future patch releases will continue to provide fixes for security vulnerabilities &amp; might not provide support to any new OS or Browser.</p>\n"},{"lang":"ja","x_late":"<p>SMH EOLの利用規約によれば、将来のパッチリリースは安全上の脆弱性の解決策の提供を続けます、&新しい OSまたはブラウザーのサポートは提供しません。</p>\n"}],"files":[{"bytes":"19732832","datemodified":"2020-07-16T06:58:47","file_list":["0x0409.ini","0x0411.ini","0x0804.ini","cp043048.xml","cpqinstall.bat","cp_data.xml","data1.cab","data1.hdr","data2.cab","elmsetup.dll","hpsmh.frm","hpsmh.frm.ja","hpsmh_config_en.xml","hpsmh_config_ja.xml","hpsmh_config_zh.xml","ISSetup.dll","layout.bin","setup.exe","setup.ini","setup.inx","setup.iss","smhsetup.exe"],"md5sum":"668b55c4d241ff4c7f645155606fd062","name":"cp043048.exe","release":"2020-07-16T06:55:05","revision":"0","sha1sum":"003db6d7816f522289ef1bf485873855e4b6f253","size":"18MB","target_guids":[],"type_of_change":"1","version":"7.6.6.2"}],"id":{"product":"efbcca27fdf947149d2bf0ed9f4fb6db","version":"24955e8cb0a24fb2acdd537b545f5af0"},"installation":{"command":"cpqinstall.bat","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ol>\n <li>\n  Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>\n <li>\n  Change to the directory.</li>\n <li>\n  Run the .exe file by double-clicking it. A dialog box will display.</li>\n <li>\n  Click the &lsquo;Install&rsquo; button to install the SMH.</li>\n</ol>\n"},{"lang":"ja","x_late":"<ol>\n <li>\n  ソフトウェアをインストールするサーバーのローカルディレクトリにSmartコンポーネント（cpxxxxxx.exe)）ファイルをダウンロードします。</li>\n <li>\n  そのディレクトリに移動します。</li>\n <li>\n  .exeファイルをダブルクリックして実行します。 ダイアログボックスが表示されます。</li>\n <li>\n  [インストール]ボタンをクリックしてSMHをインストールします。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的 HPE System Management Homepage"},{"lang":"en","x_late":"HPE System Management Homepage for Windows x64"},{"lang":"ko","x_late":"Windows x64용 HPE System Management Homepage"},{"lang":"cn","x_late":"用于 Windows x64 的 HPE System Management Homepage"}],"prerequisites":{"required_diskspace":{"size_kb":"70000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Small Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"ebs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Essential Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"1","name":"Microsoft Windows Small Business Server 2011 Standard and Essentials","platform":"nt_x86-64","sr":"OEM"},{"edition":"R2","major":"6","minor":"1","name":"Microsoft Windows Storage Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Storage Server 2008 x64 Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-03T06:43:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><br />\nUpdated the following components:</p>\n\n<ul>\n\t<li>PHP to version 5.6.30</li>\n\t<li>Zlib to version 1.2.11</li>\n\t<li>Libxslt to version 1.1.32</li>\n\t<li>PCRE to version 8.41</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated the following components:</p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Apache to version 2.4.41</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"","value":"HPE System Management Homepage Software"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"hpsmhd.exe","sw_key_expectedpath":"%systemdrive%\\hp\\hpsmh\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"978905","datemodified":"2021-03-08T20:16:34","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"6a3c58bf25de820d0d57cd829268fb3b","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"8b5de4adc1f362a2760a7c9eaddcad4810e483e2","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1050641","datemodified":"2021-03-08T20:22:21","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"f7e0721ba79cc0efd1cce3dd9ea099b9","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"9851f2e3917fa0b45efdf331c67a3cb7e2347bc9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"86e4b3a553494874939d56f97075cb67","version":"cf72dc2669f74c42816776cc86d25202"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"292359","datemodified":"2021-02-22T14:44:45","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/sbin/nvme","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"82bfe5209db484425fb79c17107ba93a","name":"HPE-NFC-host-agent-SLES-1.0-1.x86_64.rpm","release":"2021-02-22T14:40:17","revision":"0","sha1sum":"693ea8c18ca6407b417414c60879421e8422d54a","size":"285KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50573ade"],"type_of_change":"1","version":"1.0-1"}],"id":{"product":"8bba948f5c6540eba0ebe40d14f02daf","version":"6e2aca9aaeff443e8ba147dbf8be1528"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for SuSE Linux Enterprise Server 12 Service Pack4/12 Service Pack5/15 Service Pack1/15 Service Pack2"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-22T10:25:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>None.</li>\n</ul>\n"}],"files":[{"bytes":"17434849","datemodified":"2021-01-27T19:56:33","file_list":["/CP045623_BUILD_3.data","/CP045623.vmexe","/CP045623.vmexe64","/CP045623.vmfile","/CP045623_VMw.zip","/CP045623.xml","/payload.json","/CP045623_VMw.zip/index.xml","/CP045623_VMw.zip/vendor-index.xml","/CP045623_VMw.zip/metadata.zip","/CP045623_VMw.zip/vib20/CP045623/HPE_bootbank_CP045623_HPD7.3-7.0.0.15843807.vib","/CP045623_VMw.zip/metadata.zip/vendor-index.xml","/CP045623_VMw.zip/metadata.zip/vmware.xml","/CP045623_VMw.zip/metadata.zip/vibs/CP045623--2984118557896310434.xml","/CP045623_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045623_HPD7.3-7.0.0.15843807.xml"],"md5sum":"21b0cee29597eb0d980f88d35592a407","name":"CP045623.zip","release":"2021-01-27T19:53:05","revision":"0","sha1sum":"2197f41b791dcc6273570a35a88dcb93d5b74a12","size":"16MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP045623","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"ce1fbf38afa940d590b86cded0a4b8a1","version":"49ae20d0938846e8ac471a7291d80175"},"installation":{"command":"CP040688.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH0600JDYTN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:26:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.Â </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.ÃÂ </li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、ESXi 6.5上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28084706","datemodified":"2021-01-22T14:38:34","file_list":["/CP045192_VMw.zip","/CP045192.vmexe","/CP045192.vmfile","/CP045192.xml","/payload.json","/README.txt","/CP045192_VMw.zip/index.xml","/CP045192_VMw.zip/vendor-index.xml","/CP045192_VMw.zip/CP045192-build-metadata.zip","/CP045192_VMw.zip/vib20/CP045192/HPE_bootbank_CP045192_1.0.1-6.5.0.4240417.vib","/CP045192_VMw.zip/CP045192-build-metadata.zip/vmware.xml","/CP045192_VMw.zip/CP045192-build-metadata.zip/vendor-index.xml","/CP045192_VMw.zip/CP045192-build-metadata.zip/bulletins/Smart-Component-CP045192_1.0.1-6.5.0.4240417.xml","/CP045192_VMw.zip/CP045192-build-metadata.zip/vibs/CP045192--7246102643482712221.xml"],"md5sum":"c2c777f0ac3e2027770c2ccdffafefea","name":"CP045192.zip","release":"2021-01-22T15:55:05","revision":"0","sha1sum":"420c82e6760883030f2d1d1b01665c1a4d3e48c6","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.9","vib_list":[{"name":"CP045192","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"80d81c90aa4043f99c110cbf04419c83","version":"7eea3d0d76d542e1a9e9f0ddd51dbb40"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 6.5)"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>cq_overrun counter: This counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.28.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for following features:</p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>ixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>&nbsp;An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>The&nbsp;eth_wqe_too_small counter to count&nbsp;ODP page used to fail.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2106672","datemodified":"2021-01-22T06:19:51","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp042531.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"70bddcb672a4073702eba56c4ffc5c72","name":"cp042531.exe","release":"2021-01-22T06:15:07","revision":"0","sha1sum":"1c8579aae70413450d0cd5adada0b4d02ecd7bb5","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"a1ae47134c0e4b378bbf0bb2397b9e93","version":"ea73ab010f9c451db16cdcf52a0343da"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p> </p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2/2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:45:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2012R2"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1516024","datemodified":"2021-01-09T08:49:03","file_list":["cp041201.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"76e2e90a56f8e4ddc188ab5a75e0ab30","name":"cp041201.exe","release":"2021-01-09T08:34:05","revision":"0","sha1sum":"0785d683da101c8e7002780b22920dea67266a60","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"type_of_change":"0","version":"1.5.74.0"}],"id":{"product":"5e67b3914b754070a44558f816a7dbab","version":"ba7c3ec561b9456ba9f23f1d36a9b5ee"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"icea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.04.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.04.07"},{"DeviceName":"HPE 84Q 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532159000FC","Version":"03.82.00"},{"DeviceName":"HPE 82Q 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3263","Version":"03.82.00"},{"DeviceName":"HPE 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3262","Version":"03.82.00"},{"DeviceName":"HPE SN1000Q 16GB 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E8","Version":"06.04.04"},{"DeviceName":"HPE SN1000Q 16GB 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E7","Version":"06.04.04"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13019165","datemodified":"2021-01-21T15:43:51","file_list":["/CP044782_BUILD_19.data","/CP044782.vmexe","/CP044782.vmexe64","/CP044782.vmfile","/CP044782_VMw.zip","/CP044782.xml","/payload.json","/CP044782_VMw.zip/index.xml","/CP044782_VMw.zip/vendor-index.xml","/CP044782_VMw.zip/metadata.zip","/CP044782_VMw.zip/vib20/CP044782/HPE_bootbank_CP044782_2021.02.01.19-7.0.0.15843807.vib","/CP044782_VMw.zip/metadata.zip/vendor-index.xml","/CP044782_VMw.zip/metadata.zip/vmware.xml","/CP044782_VMw.zip/metadata.zip/vibs/CP044782-4319140030588064638.xml","/CP044782_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044782_2021.02.01.19-7.0.0.15843807.xml"],"md5sum":"542e0371996d63fa2c14a229a5a3e511","name":"CP044782.zip","release":"2021-01-21T15:40:04","revision":"0","sha1sum":"b5a7a7d4004f42466eeaecd8c50adf26e0aaf806","size":"12MB","target_guids":["a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4","a6b1a447-382a-5a4f-1077-2532159000FC","a6b1a447-382a-5a4f-1077-2532103C3263","a6b1a447-382a-5a4f-1077-2532103C3262","a6b1a447-382a-5a4f-1077-2031103C17E8","a6b1a447-382a-5a4f-1077-2031103C17E7","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044782","version":"2021.02.01.19-7.0.0.15843807"}]}],"id":{"product":"5f15a26843724cddbeb0234b8805431e","version":"9499ad761fdf44d19a561f604fb4fb64"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb,&nbsp;16 Gb and 32 Gb&nbsp;products.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>8Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 3.82.00</li>\n\t\t<li>Firmware 8.08.207</li>\n\t\t<li>UEFI 7.00</li>\n\t\t<li>BIOS 3.56</li>\n\t</ul>\n\t</li>\n\t<li>16Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 6.03.00</li>\n\t\t<li>Firmware 8.08.231</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.43</li>\n\t</ul>\n\t</li>\n\t<li>32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;&nbsp;\n\t<ul>\n\t\t<li>Package 02.03.06</li>\n\t\t<li>Firmware 09.04.01</li>\n\t\t<li>UEFI 7.08</li>\n\t\t<li>BIOS 0.0</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"可更新 HP Apollo 45xx Gen9 背板扩展卡机箱固件的补充更新/在线 ROM 刷新组件"},{"lang":"tw","x_late":"補充更新/線上 ROM 更新智慧型元件，可升級 HPE Apollo 45xx Gen9 背板擴充卡的機櫃韌體"},{"lang":"ko","x_late":"HPE Apollo 45xx Gen9 백플레인 익스팬더에서 인클로저 펌웨어를 업그레이드하는 추가 업데이트/온라인 ROM 플래시 스마트 구성요소"},{"lang":"ja","x_late":"HPE Apollo 45xx Gen9バックプレーンエキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.08<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.08<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;Expander may reset during heavy SSACLI polling</li>\n\t<li>SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5365578","datemodified":"2018-11-01T05:03:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/CP038041.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/firmware-Release-2.50-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-2.50-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP038041.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP038041.scexe"],"md5sum":"47a8570534c0e4cfb57598dc238bba88","name":"firmware-smartarray-7bdfcd246b-2.50-1.1.x86_64.rpm","release":"2018-11-01T09:57:37","revision":"0","sha1sum":"85b0683a551edc1055bba0bbd0b518bf40ca0b28","size":"5MB","target_guids":[],"type_of_change":"0","version":"2.50"}],"id":{"product":"e73b53ae478842daa9ba4db7eebbb5d9","version":"ff093ea8bb8044479b111b93d7be75ee"},"installation":{"command":"CP038041.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP038041.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7bdfcd246b-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP038041.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7bdfcd246b-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7bdfcd246b-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE Apollo 45xx Gen9 Backplane Expander Firmware "},{"lang":"ja","x_late":"サプリメンタルアップデート / オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-12-01T09:38:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>&nbsp;Expander may reset during heavy SSACLI polling</li>\n\t<li>SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for the ConnectX®-4 and ConnectX®-5 adapters for VMware ESXi 7.0 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx5は、VMware ESXi 7.0 Mellanox Ethernetアダプター用ConnectX®-4およびConnectX®-5アダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"851665","datemodified":"2020-11-11T14:46:28","file_list":["/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip","/cp046265.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/doc/README.txt","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/doc/release_note_nmlx5-core_4.19.70.1-1OEM.700.1.0.15525992.pdf","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/index.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/vendor-index.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.19.70.1-1OEM.700.1.0.15525992.vib","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.19.70.1-1OEM.700.1.0.15525992.vib","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip/vibs/nmlx5-rdma-3901361274948169490.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip/vibs/nmlx5-core-2117862798458469491.xml","/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686-package.zip/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992_16253686.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.19.70.1-1OEM.700.1.0.15525992.xml"],"md5sum":"1c9062a45513cffbaecb49441b3234d0","name":"cp046265.zip","release":"2020-11-11T14:44:06","revision":"0","sha1sum":"6d04b93ee35c31892a8d60812d9013ea3427d2d0","size":"831KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec38df96d3","20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx5-rdma","version":"4.19.70.1-1OEM.700.1.0.15525992"},{"name":"nmlx5-core","version":"4.19.70.1-1OEM.700.1.0.15525992"}]}],"id":{"product":"45e5e3b4b5524afa8388b9297cf98327","version":"68feffecfa7c4ed787894a1cbe74c572"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware 7.0"},{"lang":"ja","x_late":"nmlx5_enドライバーコンポーネントfor VMware 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>No Changes and New Features are included&nbsp;in smart component version 2020.05.26:</strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 4.19.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>support for Data Center Bridging Capability Exchange (DCBx) protocol.DCBX works with LLDP to allow switches to exchange information about their Data Center Bridging (DCB) capabilities and configuration and automatically</p>\n\n\t<p>negotiate common Priority-Based Flow Control (PFC) parameters.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n\t<li>\n\t<p>Support for setting the minimal bandwidth guarantee for traffic classes (TCs).</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>No&nbsp;fixes are included in&nbsp;version 4.19.70.1:</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>No Changes and New Features are included&nbsp;in smart component version 2020.11.11:</strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 4.19.70.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>support for Data Center Bridging Capability Exchange (DCBx) protocol.DCBX works with LLDP to allow switches to exchange information about their Data Center Bridging (DCB) capabilities and configuration and automatically</p>\n\n\t<p>negotiate common Priority-Based Flow Control (PFC) parameters.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n\t<li>\n\t<p>Support for setting the minimal bandwidth guarantee for traffic classes (TCs).</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>No&nbsp;fixes are included in&nbsp;version 4.19.70.1:</strong></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"","value":"HPE Apollo sx40 Server"}],"sw_keys":[{"name":"Mellanox-nmlx5:4.19.70.1-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"nmlx5-core:4.19.70.1-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.19.70.1-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"MicroserverGen10PlusSPS_05.01.04.208.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8406916","datemodified":"2020-11-05T06:27:15","file_list":["MicroserverGen10PlusSPS_05.01.04.208.signed.bin","MicroserverGen10PlusSPS_05.01.04.208.xml","payload.json"],"md5sum":"576f703c2fb2b53ab0f301b8430eac99","name":"MicroserverGen10PlusSPS_05.01.04.208.fwpkg","release":"2020-11-05T06:23:05","revision":"0","sha1sum":"822a1474ad4553806437aed3ec3256445da7e2ac","size":"8MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"134da74460bf4b5aa8511e630ba5a272","version":"f5940b85bb0f4f508bfc58c76930c885"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T03:12:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3292408","datemodified":"2020-12-11T11:56:39","file_list":["cp045600.xml","cpqsetup.exe","GPM1643SAMD8.rel","payload.json","setup.dll"],"md5sum":"65676f1fec7cc2b2ae2150eed1f48fe4","name":"cp045600.exe","release":"2020-12-11T11:46:07","revision":"0","sha1sum":"a793339832bc21387ad93a75ef84ae80374aa2e1","size":"3MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"b5c5978ca68a42089c65763237c54346","version":"8dae361972e3442d876b0dde42972685"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:10:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) devices on Windows x86_64 platform. See the supported devices list in the Supported devices section."},{"lang":"ja","x_late":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作)デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。 [サポートされるデバイス]セクションでサポートされるデバイスのリストを参照してください。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15785992","datemodified":"2020-11-12T07:53:23","file_list":["cp045905.xml","cpqsetup.exe","fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"feae578e4cc50a0ec032360edf98ab4b","name":"cp045905.exe","release":"2020-11-12T07:50:04","revision":"0","sha1sum":"11e9198d1258a0e94f559129217571e6c5919c4d","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.0.12"}],"id":{"product":"637d540b39214addb4d18ef0c3a8cbbf","version":"34bf979025e44dc3851a5dd91737e087"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Windows x86_64 platform"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Windows x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1620000","datemodified":"2019-10-24T20:25:43","file_list":["bepnic.dll","bepnic.rtf","cp039929.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"7c9836016edf09e02edce14a6fa51f7d","name":"cp039929.exe","release":"2019-10-24T20:12:04","revision":"0","sha1sum":"42ace1f9c1c2796a16a785db79589cb2bb682e3a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"a696c5bfe8e646f9a237f7c9cfde41c1","version":"638ce062f75648068866f21f5aaffa14"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"HPE 系統狀況應用程式與命令列公用程式 (hp-health) 彙集了應用程式及工具，可讓您監視風扇、電源供應器、溫度感應器及其他管理事件。此外，亦提供一系列命令列公用程式： ProLiant 開機組態公用程式 (hpbootcfg)、ProLiant 管理命令列介面公用程式 (hpasmcli)、ProLiant 整合式管理記錄 (IML) 公用程式 (hplog) 及 UID (藍色) 燈光公用程式 (hpuid)。"},{"lang":"en","x_late":"The HPE System Health Application and Command Line Utilities (hp-health) is collection of applications and tools which enables monitoring of fans, power supplies, temperature sensors, and other management events.  It also provides collection of command-line utilities: the ProLiant  boot  configuration  utility (hpbootcfg), the ProLiant Management Command Line Interface Utility (hpasmcli), the ProLiant Integrated Management Log (IML) Utility (hplog), and the UID (blue) Light Utility (hpuid)."},{"lang":"ko","x_late":"HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티(hp-health)는 팬, 전원 공급 장치, 온도 센서 및 기타 관리 이벤트를 모니터링하도록 하는 응용 프로그램 및 도구 모음입니다. 또한 다음과 같은 명령줄 유틸리티 모음을 제공합니다. ProLiant 부팅 구성 유틸리티(hpbootcfg), ProLiant 관리 명령줄 인터페이스 유틸리티(hpasmcli), ProLiant 통합 관리 로그(IML) 유틸리티(hplog) 및 UID(블루) 라이트 유틸리티(hpuid)"},{"lang":"cn","x_late":"HPE System Health Application and Command Line Utilities (hp-health) 是一系列应用程序和工具，能够监控风扇、电源、温度传感器和其他管理事件。它还提供了命令行实用程序集： ProLiant 启动配置实用程序 (hpbootcfg)、ProLiant Management Command Line Interface Utility (hpasmcli)、ProLiant Integrated Management Log (IML) Utility (hplog) 和 UID (blue) Light Utility (hpuid)。"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ（hp-health）パッケージは、アプリケーション、およびファンの監視、電源、温度センサー、およびその他管理イベントを行うツールを集めたものです。  また、ProLiantブートコンフィギュレーションユーティリティ（hpbootcfg）、ProLiantマネジメントコマンドラインインターフェイスユーティリティ（hpasmcli）、ProLiantインテグレーテッドマネジメントログ（IML）ユーティリティ（hplog）、およびUID（青）ランプユーティリティ（hpuid）を集めたコマンドラインユーティリティも提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"328040","datemodified":"2019-12-04T05:53:12","file_list":["./opt/hp/hp-health","./opt/hp/hp-health/addons","./opt/hp/hp-health/addons/libcpqci64.a","./opt/hp/hp-health/bin","./opt/hp/hp-health/bin/hp-asrd","./opt/hp/hp-health/bin/hpasmlited","./opt/hp/hp-health/bin/hpasmpld","./opt/hp/hp-health/bin/hpasmxld","./opt/hp/hp-health/examples","./opt/hp/hp-health/examples/lite-mgmt","./opt/hp/hp-health/examples/lite-mgmt/COPYING.txt","./opt/hp/hp-health/examples/lite-mgmt/README.txt","./opt/hp/hp-health/examples/lite-mgmt/cma.conf.nosnmp","./opt/hp/hp-health/examples/lite-mgmt/hpsysmon.sh","./opt/hp/hp-health/hp-health.license","./opt/hp/hp-health/hprpm.xpm","./opt/hp/hp-health/sh","./opt/hp/hp-health/sh/hpasmxld_reset.sh","./sbin/hpasmcli","./sbin/hpbootcfg","./sbin/hplog","./sbin/hpuid","./sbin/rchp-health","./usr/lib/systemd/scripts/hp-asrd.sh","./usr/lib/systemd/scripts/hp-health.sh","./usr/lib/systemd/system/hp-asrd.service","./usr/lib/systemd/system/hp-health.service","./usr/lib64/libcpqci64.so","./usr/lib64/libcpqci64.so.3","./usr/lib64/libcpqci64.so.3.0","./usr/lib64/libhpasmintrfc64.so","./usr/lib64/libhpasmintrfc64.so.3","./usr/lib64/libhpasmintrfc64.so.3.0","./usr/lib64/libhpev64.so","./usr/lib64/libhpev64.so.1","./usr/lib64/libhpev64.so.1.0","./usr/share/man/man4/hp-health.4.gz","./usr/share/man/man4/hpasmcli.4.gz","./usr/share/man/man7/hp_mgmt_install.7.gz","./usr/share/man/man8/hp-asrd.8.gz","./usr/share/man/man8/hpbootcfg.8.gz","./usr/share/man/man8/hplog.8.gz","./usr/share/man/man8/hpuid.8.gz","./var/log/hp-health","./var/spool/compaq","./var/spool/hp-health"],"md5sum":"0a508c85370d2e6aac96e061e3f9a647","name":"hp-health-10.92-4.4.sles12.x86_64.rpm","release":"2019-12-04T05:49:04","revision":"0","sha1sum":"ffcb1e571fd887f6c468630bead76e90cd12dcf2","size":"320KB","target_guids":[],"type_of_change":"0","version":"10.9.2"}],"id":{"product":"b196e6e9412f4744bd940867ff7e2b2a","version":"bfa05a001f3d44ed9cfcf192e7d8c96b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-health-&lt;version&gt;.rpm</P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;/etc/init.d/hp-health status</P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp-health</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;or</P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man hp_mgmt_install</P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。 </P>\n<P>      rpm -ivh hp-health-<version>.rpm</P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。 </P>\n<P>      /etc/init.d/hp-health status</P>\n<P>以下のコマンドを実行してヘルプを参照してください。 </P>\n<P>      man hp-health</P>\n<P>            または</P>\n<P>      man hp_mgmt_install</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 SUSE LINUX Enterprise Server 12 的 HPE 系統健康狀況應用程式與命令列公用程式"},{"lang":"en","x_late":"HPE System Health Application and Command Line Utilities for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE LINUX Enterprise Server 12용 HPE 시스템 상태 응용 프로그램 및 명령줄 유틸리티"},{"lang":"cn","x_late":"用于 SUSE LINUX Enterprise Server 12的HPE System Health 应用和命令行实用程序"},{"lang":"ja","x_late":"HPEシステムヘルスアプリケーションおよびコマンドラインユーティリティ for SUSE LINUX Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-21T13:54:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Modified the loop initial values in hpasmcli from 2 to 0.</li>\n\t<li>Modifications to check the read and write variables to match RBSU in Legacy and UEFI mode</li>\n\t<li>Updated the hpasmcli check string to correctly report the impitool information.</li>\n\t<li>Remove the redundant serial embedded and com ports</li>\n\t<li>Addressed&nbsp;IML message size limitation from 36 to 212 bytes</li>\n\t<li>Support for hp-health in OS security boot</li>\n\t<li>Added supporting &ldquo;quote mark&rdquo; in SET NAME command</li>\n\t<li>Enabled to set PXE as boot first&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>TBD</li>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"A24","value":"HP ProLiant SL335s G7 Server"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"O41","value":"HP ProLiant MicroServer"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"}],"sw_keys":[{"name":"hp-health","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11326288","datemodified":"2021-01-28T09:29:14","file_list":["cp046632.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_2.42_01_23_2021.signed.flash"],"md5sum":"150543cef44d4434df909b805c691b38","name":"cp046632.exe","release":"2021-01-28T09:25:15","revision":"0","sha1sum":"814205b6e844008bd93d9a8ff7388adb2ee6cec8","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"0e95d953f6c341e2ab45544cad6adaa1","version":"0dbf7497802347b9a3d62ee6eed74dd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br/>\n </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML110 Gen10 (U33)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB002000GWFGH and MB001000GWFGF Drives\n "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB002000GWFGH および MB001000GWFGF ドライブ\n "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for RHEL 8.3</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5122891","datemodified":"2020-12-13T09:23:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/CP045405.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/SNEMOTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045405.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045405.scexe"],"md5sum":"bdffd2801d475ae8fbc966f405359bff","name":"firmware-hdd-0b575b5895-HPG3-7.1.x86_64.rpm","release":"2020-12-13T09:09:07","revision":"0","sha1sum":"b3fbfd8695b15db1d8cb5e240167ac07899edfea","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"81e371ec59e54de18ebca5fd69821033","version":"dff5fe5f311243fb88329b86fbcd9f04"},"installation":{"command":"CP040332.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8917602","datemodified":"2021-02-09T15:50:30","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/12","./usr/lib/.build-id/12/c86c12a657179c1c63d1a4e432a9b0e3d7d0e7","./usr/lib/.build-id/17","./usr/lib/.build-id/17/ba35b00a33cfe13d05b12a161ddf2471bd7972","./usr/lib/.build-id/27","./usr/lib/.build-id/27/fb8222a394f590bfccd38a75dec115da205ffb","./usr/lib/.build-id/35","./usr/lib/.build-id/35/229801f0caf3cf99219845db05035f71fbe3f5","./usr/lib/.build-id/82","./usr/lib/.build-id/82/86ea0da58a69a3ec3d37d1a0a6ee28644ff4a3","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/ef9a88f1cd8954e341406f714c6e8038626616","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/d5abe6ca73c2b476f94c3dc0263e80d02bff74","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"125ab4b5b3c9500723cc434abefd99bb","name":"mft-4.16.0-105.rhel8u2.x86_64.rpm","release":"2021-02-09T15:37:04","revision":"0","sha1sum":"83c5628f33d17d154ae61977fa7b69fedf8c0b24","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"},{"bytes":"19677","datemodified":"2021-02-09T15:54:52","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-193.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"ab3d0c3e820e47ba715f1655ce277a5c","name":"kmod-kernel-mft-mlnx-4.16.0-1.rhel8u2.x86_64.rpm","release":"2021-02-09T15:37:04","revision":"0","sha1sum":"a00250c26ceae2df166033e186c27e6a39d19a16","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"}],"id":{"product":"2339c17ea9cc43149a8dccb1a0ff379a","version":"35f5b59f662b462fae78d81b1bdb2cac"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-147.el8&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.16.0-1.rhel8u2.x86_64.rpm&nbsp;&nbsp;mft-4.16.0-105.rhel8u2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 2 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWBHR"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWBHR Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16135828","datemodified":"2021-01-27T09:13:54","file_list":["/CP045716_BUILD_3.data","/CP045716.vmexe","/CP045716.vmexe64","/CP045716.vmfile","/CP045716_VMw.zip","/CP045716.xml","/payload.json","/CP045716_VMw.zip/index.xml","/CP045716_VMw.zip/vendor-index.xml","/CP045716_VMw.zip/metadata.zip","/CP045716_VMw.zip/vib20/CP045716/HPE_bootbank_CP045716_HPD4.3-7.0.0.15843807.vib","/CP045716_VMw.zip/metadata.zip/vendor-index.xml","/CP045716_VMw.zip/metadata.zip/vmware.xml","/CP045716_VMw.zip/metadata.zip/vibs/CP045716--1893179554550613382.xml","/CP045716_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045716_HPD4.3-7.0.0.15843807.xml"],"md5sum":"2528d7861ba2086133acc1a0676ab980","name":"CP045716.zip","release":"2021-01-27T09:11:05","revision":"0","sha1sum":"7a1cd4fe1f622acb64ccdafa153708315cca4e78","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045716","version":"HPD4.3-7.0.0.15843807"}]}],"id":{"product":"2a7080d78048494dac265180eef80ae1","version":"480f1c6cad16406fa7b2bba740fc045b"},"installation":{"command":"CP040530.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:46:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8681882","datemodified":"2021-03-15T22:23:02","file_list":["/CP047162.vmexe","/CP047162.vmexe64","/CP047162.vmfile","/CP047162.xml","/README.txt"],"md5sum":"7313c62802585c89d654794c54c05046","name":"CP047162.zip","release":"2021-03-16T03:20:05","revision":"0","sha1sum":"9abcffab84b865f5b56c46edd954049126a25ed7","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"c9be2188c9e74afcbe220603b395a9de","version":"b0207fb074524603989f1a74cd1603c6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL560 Gen9（P85）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T02:57:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800095","languages":[{"lang":"fr","x_late":"Logiciel - Réseau"},{"lang":"en","x_late":"Software - Network"},{"lang":"cn","x_late":"软件 - 网络"},{"lang":"tw","x_late":"軟體 ─ 網路"},{"lang":"de","x_late":"Software - Netzwerk"},{"lang":"ko","x_late":"소프트웨어 - 네트워크"},{"lang":"it","x_late":"Software - Rete"},{"lang":"ja","x_late":"ソフトウェア - ネットワーク"},{"lang":"es","x_late":"Software - Red"}]}],"description":[{"lang":"tw","x_late":"此代理程式會從執行 Linux x86_64 平台的 HPE 伺服器內受支援的 Broadcom 網路配接卡擷取感測器與健康狀況資料。"},{"lang":"en","x_late":"This agent extracts sensor and health data from supported Broadcom network adapters in HPE servers running Linux x86_64 platforms."},{"lang":"ko","x_late":"이 에이전트는 Linux x86_64 플랫폼이 탑재된 HPE 서버에서 지원 가능한 Broadcom 네트워크 어댑터를 통해 센서 및 상태 데이터를 추출합니다."},{"lang":"cn","x_late":"该代理可在运行 Linux x86_64 平台的 HPE 服务器中从支持的 Broadcom 网络适配器解压传感器和状态数据。"},{"lang":"ja","x_late":"このエージェントは、Linux x86_64プラットフォームを実行しているHPEサーバーでサポートされているBroadcomネットワークアダプターから、センサーおよびヘルスのデータを抽出します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22582","datemodified":"2018-10-17T21:13:35","file_list":["./etc/init.d/tg3sd","./usr/sbin/tg3sd","./usr/share/smartupdate/hp-tg3sd/component.xml"],"md5sum":"f3cb58e5e6ed18e996779ca82fd9d0f5","name":"hp-tg3sd-1.0.21-1.x86_64.rpm","release":"2018-10-17T21:13:06","revision":"0","sha1sum":"e9b006a325a6ae02b7aa54a5e69e22cb8fb63347","size":"22KB","target_guids":[],"type_of_change":"0","version":"1.0.21-1"}],"id":{"product":"9927526d75db4a7cba662ab57f85142d","version":"ab99ef45554b4bb39a66f33a98247a6b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download hp-tg3sd-1.0.21-1.x86_64.txt to view installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 HPE ProLiant 網路配接卡的 Broadcom Active Health System 代理程式 (用於 Linux x86_64)"},{"lang":"en","x_late":"Broadcom Active Health System Agent for HPE ProLiant Network Adapters for Linux x86_64"},{"lang":"ko","x_late":"HPE 프로라이언트 네트워크 어댑터용 Broadcom Active Health System Agent(Linux x86_64)"},{"lang":"cn","x_late":"适用于采用 Linux x86_64 的 HPE ProLiant 网络适配器的 Broadcom Active Health System 代理"},{"lang":"ja","x_late":"HPE ProLiantネットワークアダプター for Linux x86_64用Broadcom Active Health Systemエージェント"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product adddresses a library dependency issue seen when installing&nbsp;on a system running SUSE Linux Enterprise Server 15.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hp-tg3sd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85030G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85030G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive model: VS000480KXALB"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi -&nbsp; VS000480KXALB Drive<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; 85030G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Added support for VMware 7.0 U1</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> Requires iLO5 v2.30 or later</p>\n"}],"files":[{"bytes":"21522764","datemodified":"2020-07-28T20:47:16","file_list":["/CP044993_BUILD_2.data","/CP044993.vmexe","/CP044993.vmexe64","/CP044993.vmfile","/CP044993_VMw.zip","/CP044993.xml","/payload.json","/CP044993_VMw.zip/index.xml","/CP044993_VMw.zip/vendor-index.xml","/CP044993_VMw.zip/metadata.zip","/CP044993_VMw.zip/vib20/CP044993/HPE_bootbank_CP044993_85030G00.2-7.0.0.15843807.vib","/CP044993_VMw.zip/metadata.zip/vendor-index.xml","/CP044993_VMw.zip/metadata.zip/vmware.xml","/CP044993_VMw.zip/metadata.zip/vibs/CP044993--5538192343067526082.xml","/CP044993_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044993_85030G00.2-7.0.0.15843807.xml"],"md5sum":"8247dc292750a61da4d6ca64baa88446","name":"CP044993.zip","release":"2020-07-28T20:44:04","revision":"0","sha1sum":"d97f0b66053ab08f465167f9408f07b09185dcd6","size":"20MB","target_guids":["562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85030G00","vib_list":[{"name":"CP044993","version":"85030G00.2-7.0.0.15843807"}]}],"id":{"product":"fc28c0050f9d4a8a94e83f990b230b39","version":"302e50c98c034815b721393b01e8b8a3"},"installation":{"command":"CP042969.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"SK Hynix"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-27T10:12:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, and MB4000GDUPB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, およびMB4000GDUPBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     HPG3<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>"}],"files":[{"bytes":"3375736","datemodified":"2020-12-16T20:46:52","file_list":["cp045536.xml","cpqsetup.exe","payload.json","setup.dll","TAHARRG4.REL"],"md5sum":"36729324e527ada9883043065a846dc6","name":"cp045536.exe","release":"2020-12-16T20:08:05","revision":"0","sha1sum":"8b1ade3cb6ad4b624b1156f88bec9d914e50b259","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"dceed791e6be42c1ba1f138aa6af8451","version":"fa97b606ff334d348d1c86647d5275db"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:44:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD3"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB004000JWFVK and MB006000JWFVL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWFVKおよびMB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4862122","datemodified":"2020-12-13T09:21:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/CP045410.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/TATCATdsHPD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045410.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045410.scexe"],"md5sum":"79f4f634ecef631adbe737f0eae7c676","name":"firmware-hdd-f6d00bd17e-HPD3-3.1.x86_64.rpm","release":"2020-12-13T09:09:10","revision":"0","sha1sum":"0b8f2c6862bc1f4e25dd23e54b8da9e858eac01f","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"07fc1a5a961a427ba3c2e3f341d3886e","version":"cd70587982ba46b7a4ec1621f047e38f"},"installation":{"command":"CP041750.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB004000JWFVK and MB006000JWFVL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、およびMB4000GDUPBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"16838754","datemodified":"2021-01-27T17:29:02","file_list":["/CP045648_BUILD_3.data","/CP045648.vmexe","/CP045648.vmexe64","/CP045648.vmfile","/CP045648_VMw.zip","/CP045648.xml","/payload.json","/CP045648_VMw.zip/index.xml","/CP045648_VMw.zip/vendor-index.xml","/CP045648_VMw.zip/metadata.zip","/CP045648_VMw.zip/vib20/CP045648/HPE_bootbank_CP045648_HPG4.3-7.0.0.15843807.vib","/CP045648_VMw.zip/metadata.zip/vendor-index.xml","/CP045648_VMw.zip/metadata.zip/vmware.xml","/CP045648_VMw.zip/metadata.zip/vibs/CP045648-5240493251313420301.xml","/CP045648_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045648_HPG4.3-7.0.0.15843807.xml"],"md5sum":"332e62e8cafb38fcfed6597984831b35","name":"CP045648.zip","release":"2021-01-27T17:26:08","revision":"0","sha1sum":"c434fe527b2067df96de889aa3e0db01386703ce","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045648","version":"HPG4.3-7.0.0.15843807"}]}],"id":{"product":"9635a1b56d544167b79937e43283b144","version":"60f1eeba19364474aba032aeccbbaa16"},"installation":{"command":"CP040506.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:48:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5568944","datemodified":"2020-12-13T09:03:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/CP045403.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/HBCMSssseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045403.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045403.scexe"],"md5sum":"f785a4331c5724f8255982365b583c85","name":"firmware-hdd-5dcf26fa42-HPD2-5.1.x86_64.rpm","release":"2020-12-13T08:48:11","revision":"0","sha1sum":"3bfe1f5c008e0cdedf66484c228053e1465a0d74","size":"5MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"896ea0712e9c4853949ccb47860e6c63","version":"a607c64dc4e24919959f820b7b1b20d7"},"installation":{"command":"CP040329.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.334.6 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2288168","datemodified":"2020-12-03T18:50:54","file_list":["cp044767.xml","cpqsetup.exe","elxdrvr-fc-12.8.334.6-4.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"f1a6451c86bff70b6746a160747c1254","name":"cp044767.exe","release":"2020-12-03T18:41:06","revision":"0","sha1sum":"38e0916be7ad34dc19ef0d8d2c047bf2d0319bcf","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.334.6"}],"id":{"product":"1cf7a310ab4d4c49af4f9d9368690f44","version":"919054f32bcb4beaad1c56bed50c230a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.6.165.0&nbsp;&nbsp;&nbsp;</p>\n\n<p>Added the following support :</p>\n\n<p><br />\nRemoved the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Hyper-V Virtual Machines (VMs) could not access storage arrays if those Virtual Machine (VM) had been shut down and restarted over 512 times.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE Smartアレイコントローラードライバーコンポーネント for VMware vSphere 6.5。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"190821","datemodified":"2020-12-04T05:36:58","file_list":["/cp042874.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/vendor-index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/vib20/nhpsa/Microsemi_bootbank_nhpsa_65.0072.0.149-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nhpsa-65.0072.0.149.xml","/VMW-ESX-6.5.0-nhpsa-65.0072.0.149-offline_bundle-17204132.zip/metadata.zip/vibs/nhpsa-2476583018873965280.xml"],"md5sum":"a32343ec19cd184991491b3890356395","name":"cp042874.zip","release":"2021-03-24T00:00:00","revision":"1","sha1sum":"2e8c2c29f166ed3a8db2e10f5f0232b3944f7e45","size":"186KB","target_guids":[],"type_of_change":"1","version":"2021.01.01","vib_list":[{"name":"nhpsa","version":"65.0072.0.149-1OEM.650.0.0.4598673"}]}],"id":{"product":"386613fae09d49a9a12412011f349ab9","version":"7fafbccf73f544149a7288af9db8da43"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">.</a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">を使用して、SPPをUSBキーにコピーします。</a></li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br/>\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller Driver for VMware vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"HPE ProLiant Smartアレイコントローラードライバー for VMware vSphere 6.5（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323C","subdev":"1929","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-25T14:40:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>To add OS support for VMware ESXi 7.0 U1 P02</li>\n</ul>\n","latest_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"nhpsa:65.0072.0.149-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Dynamic Smart Array controller driver component(hpdsa) for VMware vSphere 6.5, for use with Smart Update Manager."},{"lang":"ja","x_late":"Smart Update Managerとともに使用するためのVMware vSphere 6.5用HPE Dynamic Smartアレイコントローラードライバーコンポーネント（hpdsa）"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"943983","datemodified":"2019-05-08T14:12:08","file_list":["/cp039786.xml","/hpdsa-5.5.0.68.zip","/hpdsa-5.5.0.68.zip/index.xml","/hpdsa-5.5.0.68.zip/vendor-index.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip","/hpdsa-5.5.0.68.zip/scsi-hpdsa-5.5.0.68-1OEM.550.0.0.1331820.x86_64.vib","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vendor-index.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vmware.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/bulletins/hpdsa-5.5.0.68.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vibs/scsi-hpdsa--1775945749.xml"],"md5sum":"590b7c33f2dba431cf54e24a1fd67124","name":"cp039786.zip","release":"2019-05-08T19:11:01","revision":"0","sha1sum":"bdd7473fdf14dd167e9e2fd3ae5915f7474e236d","size":"921KB","target_guids":[],"type_of_change":"1","version":"2019.05.01","vib_list":[{"name":"scsi-hpdsa","version":"5.5.0.68-1OEM.550.0.0.1331820"}]}],"id":{"product":"19bf97ce78cd46209fcfdc12bd9d7a9f","version":"85125e14c7ed4c99a5deb7027e05e5fd"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>CD /hp/swpackages and ./hpsum</li>\n\t<li>Select the next button</li>\n\t<li>Click Add Single Target</li>\n\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>CD /hp/swpackagesおよび./hpsum</li>\n\t<li>次へボタンを選択します。</li>\n\t<li>シングルターゲットの追加をクリックします。</li>\n\t<li>更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i Controller Driver for VMware vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"HPE Dynamic SmartアレイB140iコントローラードライバーfor VMware vSphere 6.5（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-07T16:10:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the driver could report excessive errors in the debug log.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixes an issue where the driver will not upgrade due to the AHCI driver taking priority.</p>\n\n<p>&nbsp;</p>\n\n<p>This issue is only encounter when upgrading to version 2018.10.18 (5.5.0.66-1). All other versions are not affected.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"scsi-hpdsa:5.5.0.68-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6275676","datemodified":"2020-12-13T16:22:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/CP045858.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/GSM883G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045858.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045858.scexe"],"md5sum":"de89385798e9076fa87ff7c6072edc4b","name":"firmware-hdd-f693ccc138-HPG3-2.1.x86_64.rpm","release":"2020-12-13T16:09:05","revision":"0","sha1sum":"d38ac59986cdbae77d8c7e96fb4238cb729fa574","size":"5MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"17be7af3223241a4bef4e8f0da8afac5","version":"2a552d4380f242a089ee2298e95441c3"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします: </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- MK000480GWSSC、 MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T18:57:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom NetXtreme-E NIC 的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom NetXtreme-E NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom NetXtreme-E Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"336041","datemodified":"2021-01-14T07:28:37","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/bnxt_en.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"2e0731ddfdfc03cf67b497f1ef5bd57d","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_94.41-218.0.67.0.sles12sp4.x86_64.rpm","release":"2021-01-14T07:09:04","revision":"0","sha1sum":"a6d2654c5c9b84c5f6af612fae798babac0097d3","size":"328KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"305099","datemodified":"2021-01-14T07:25:00","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnxt_en.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"ae18f9765b3b422e24e0916b98302442","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_120-218.0.67.0.sles12sp5.x86_64.rpm","release":"2021-01-14T07:09:04","revision":"0","sha1sum":"d2350fa756ec97315c9bc63364d358b9ca78eb69","size":"297KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"4449ff05e7054e05a09904ed0fed74a8","version":"11a8ca6bd9b948daa9e049fbb7fe0c54"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom NetXtreme-E 驅動程式"},{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom NetXtreme-E 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E驱动程序"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5.</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value.</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fix</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18971012","datemodified":"2021-01-28T16:58:54","file_list":["/CP045980_BUILD_3.data","/CP045980.vmexe","/CP045980.vmexe64","/CP045980.vmfile","/CP045980_VMw.zip","/CP045980.xml","/payload.json","/CP045980_VMw.zip/index.xml","/CP045980_VMw.zip/vendor-index.xml","/CP045980_VMw.zip/metadata.zip","/CP045980_VMw.zip/vib20/CP045980/HPE_bootbank_CP045980_HPG3.3-7.0.0.15843807.vib","/CP045980_VMw.zip/metadata.zip/vendor-index.xml","/CP045980_VMw.zip/metadata.zip/vmware.xml","/CP045980_VMw.zip/metadata.zip/vibs/CP045980-4009730068618825415.xml","/CP045980_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045980_HPG3.3-7.0.0.15843807.xml"],"md5sum":"3991008cf641a464d3b5c34469185c10","name":"CP045980.zip","release":"2021-01-28T16:56:04","revision":"0","sha1sum":"9774486e27fb3ef37b6ffab7201f3155d1fa9e4b","size":"18MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP045980","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"4025ccc149b544568897af8cffe102f9","version":"c658eb28440f48aea407018193b2334c"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-01T21:44:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 15下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"22082","datemodified":"2020-07-06T12:06:05","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-216.0.88.3.so","./usr/lib64/libbnxt_re-rdmav16.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"3f45b8c7ad6505ae9c557e6e4903d9d3","name":"libbnxt_re-216.0.88.3-sles15sp0.x86_64.rpm","release":"2020-07-06T12:03:04","revision":"0","sha1sum":"1500872c3a497d2156cf71194a6bc24e643ac476","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"216.0.88.3"}],"id":{"product":"624db0a4b73e44c99c1f052c1aef041d","version":"ed1d4fe37d2c4f4ca536ff844f6308d9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n\n<p>Use <em>--force</em> or <em>--replacefiles</em> options while installing or updating the HPE Broadcom RoCE library on SUSE Linux Enterprise Server 15.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports&nbsp;the following network adapters.</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</li>\n</ul>\n","latest_fixes_x_late":"<p>This product adds a feature to group RoCE statistics<br />\nThis product fixes an issue to avoid VM reboot when RoCE driver was loaded on VF (of Thor).<br />\nThis product fixes RX buffer errors which reported in dmesg when running heavy jumbo traffic.</p>\n"},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now disables loading RoCE driver on VFs when Link Aggregation is enabled.</li>\n\t<li>This product now supports rdma-core v22.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot.</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for SUSE Linux Enterprise Server 12 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"958447","datemodified":"2021-04-28T10:57:52","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/4.12.14-115-default","./lib/modules/4.12.14-115-default/updates","./lib/modules/4.12.14-115-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"64ff9aeb8835821e8f7aa4de01e6ab73","name":"hpdsa-kmp-default-1.2.10-176.sles12sp5.x86_64.rpm","release":"2021-04-28T10:49:04","revision":"0","sha1sum":"a1b6d71b329e4f07be7a2f74ff7240fec4745aff","size":"935KB","target_guids":[],"type_of_change":"1","version":"1.2.10-176"},{"bytes":"961778","datemodified":"2021-04-28T10:59:09","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"b549ca3fc76e2e49f131119c3c1e2b56","name":"hpdsa-kmp-default-1.2.10-176.sles12sp4.x86_64.rpm","release":"2021-04-28T10:49:04","revision":"0","sha1sum":"de05954dd743d9eff3f09d1df97345c9a093f093","size":"939KB","target_guids":[],"type_of_change":"1","version":"1.2.10-176"}],"id":{"product":"5087e00798b842dd96c4ffa314df5670","version":"e71e8663a08241e98bddbc0bb2a47b2c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 12 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-28T10:27:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Add support for SuSE Linux Enterprise Server 12 SP5</p>\n"},{"curr_enhancements_x_late":"<p>Add support for SuSE Linux Enterprise Server 12 SP5</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Added PKCS signing process to fix the secure boot hang issue on Linux SLES12 SP5.</li>\n\t<li>Fix SATL error handling of AHCI reported Fatal errors with NCQ and Non-NCQ commands potentially causing RAID stack timeouts and excessive read/write command timeouts leading to SCSI bus reset with M.2 SSD drives configured with SW RAID.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-514180897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-560580897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-001080897a09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp042963.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-551580897a09","Version":"1.2.0.5435"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Windows Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers."},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のオンラインWindowsファームウェアコンポーネントを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"899728","datemodified":"2020-01-24T07:22:58","file_list":["cp042963.compsig","cp042963.zip","cp042965.xml","cpqsetup.exe","payload.json","SecureFlash64.dll"],"md5sum":"eed78a7c15be70cbb846f44a97f3a048","name":"cp042965.exe","release":"2020-04-01T00:00:00","revision":"1","sha1sum":"98c8e15b7aa42775c4ea1fcd8493a456bf4cb5f1","size":"878KB","target_guids":["805dd01c-eb5a-1e76-8089-514180897a09","805dd01c-eb5a-1e76-8089-560580897a09","805dd01c-eb5a-1e76-8089-001080897a09","805dd01c-eb5a-1e76-8089-551580897a09"],"type_of_change":"1","version":"1.2.0.5435"}],"id":{"product":"7be61fcc837b4a3698dfdb3d9031d2e0","version":"039b4e8fa00a459a85b5bd7d210c39ae"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ol>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ol>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>:</strong></strong></p>\n\n<ol>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ol>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ol>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ol>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\packagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネント for Windows x64 - HPE Gen10サーバー上のIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-06T05:30:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</p>\n\n<p>This product contains mainly performance improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Agentless Management Smart Component for ESXi 7.0 includes the latest HPE Agentless Management Service (AMS), and AMS ESXCLI Interface."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"600458","datemodified":"2021-01-28T18:49:15","file_list":["/cp044741.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip","/amshelprComponent_701.11.7.0.14-1_17510219.zip/index.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip/vendor-index.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip/metadata.zip","/amshelprComponent_701.11.7.0.14-1_17510219.zip/vib20/amshelpr/HPE_bootbank_amshelpr_701.11.7.0.14-1OEM.701.0.0.16555998.vib","/amshelprComponent_701.11.7.0.14-1_17510219.zip/metadata.zip/vendor-index.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip/metadata.zip/vmware.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip/metadata.zip/vibs/amshelpr--2848261136938564240.xml","/amshelprComponent_701.11.7.0.14-1_17510219.zip/metadata.zip/bulletins/amshelprComponent_701.11.7.0.14-1.xml"],"md5sum":"6a0208aa80d8ce9c8095dc4b8e6da124","name":"cp044741.zip","release":"2021-01-28T18:47:13","revision":"0","sha1sum":"e7841699100fe0c98b94ebdfacb21e24a4118786","size":"586KB","target_guids":[],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"amshelpr","version":"701.11.7.0.14-1OEM.701.0.0.16555998"}]}],"id":{"product":"06046a88182e43b38ad262913cbf0784","version":"2d5a58e0a38946b8882662e79b025c5e"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (HPSUM) from the HPE Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Agentless Management Bundle Smart Component for Gen9 on ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-04-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix false NVMe disk temperature alerts</li>\n\t<li>Fix missing OS, driver and software info from AHS logs</li>\n\t<li>Fix max and threshold temperature values for SATA disks to prevent fans from running at higher rate</li>\n\t<li>Fix false SATA disk status change alerts<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Implemented new vSphere 7.0U1 Daemon interface and is only supported on vSphere 7.0U1 and newer.&nbsp;&nbsp; New &quot;esxcli daemon control&quot; commands are now used to stop/start/restart AMS.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fixed resource leak when AHS logging fails</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"}],"sw_keys":[{"name":"amshelpr:701.11.7.0.14-1OEM.701.0.0.16555998","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.40 (02/24/2021)"},{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022e","Version":"v2.40 (02/24/2021)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34204144","datemodified":"2021-02-25T15:54:59","file_list":["A48_2.40_02_24_2021.signed.flash","cp046362.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"f23860ba4770635c885aaf3993f6bbf3","name":"cp046362.exe","release":"2021-02-25T15:53:04","revision":"0","sha1sum":"a130b8298e994e19695c87a8ece211840c95d845","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f","00000000-0000-0000-0000-00000000022e"],"type_of_change":"0","version":"2.40_02-24-2021"}],"id":{"product":"3702e2a6624243b4a85fa9ca1f4c0ce2","version":"8acda249fcb04e14816b494dc870a9e7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-30T19:44:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB4000JEQNL and MB6000JEQNN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEQNLおよびMB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17424867","datemodified":"2021-01-28T12:07:41","file_list":["/CP045659_BUILD_3.data","/CP045659.vmexe","/CP045659.vmexe64","/CP045659.vmfile","/CP045659_VMw.zip","/CP045659.xml","/payload.json","/CP045659_VMw.zip/index.xml","/CP045659_VMw.zip/vendor-index.xml","/CP045659_VMw.zip/metadata.zip","/CP045659_VMw.zip/vib20/CP045659/HPE_bootbank_CP045659_HPDB.3-7.0.0.15843807.vib","/CP045659_VMw.zip/metadata.zip/vendor-index.xml","/CP045659_VMw.zip/metadata.zip/vmware.xml","/CP045659_VMw.zip/metadata.zip/vibs/CP045659-5161517877541110386.xml","/CP045659_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045659_HPDB.3-7.0.0.15843807.xml"],"md5sum":"45baa4413c7f786d4798f327db60831d","name":"CP045659.zip","release":"2021-01-28T12:05:04","revision":"0","sha1sum":"247825d74be638c83e63595c2d61062fefbb0e22","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP045659","version":"HPDB.3-7.0.0.15843807"}]}],"id":{"product":"dffb1787348c4681b9170fbc360355c9","version":"ff123b0c3de3404abe8ad6ad4209b0fb"},"installation":{"command":"CP039424.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:01:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5624787","datemodified":"2021-01-28T09:32:18","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"fca5e6c3404a3f05f32e3008815ff7e5","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel8u2.x86_64.rpm","release":"2021-01-28T09:21:17","revision":"0","sha1sum":"8b37d8b325c90aa1899f6553983a1f263dd94e3a","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"2eef2276e4ef4f45a356ace7c4982af7","version":"718436bd5b3e4abc9ea382d86306b610"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 2 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to&nbsp;Driver version&nbsp;10.01.00.64.08.0-k1</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"427474","datemodified":"2021-01-28T10:49:28","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"ba4e2e1fdc4fe338383b71ad8269035f","name":"brcmfcoe-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-28T10:45:05","revision":"0","sha1sum":"d9b07ecec9613988139e8e7a670aed4d78d14274","size":"417KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"81798df39029402e8ad9bf5a76183ca6","version":"db28952d84d0440985e77d385dccc151"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />\n<br />\n                    Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 service pack 2 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:37:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1259.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5018337","datemodified":"2020-12-13T16:42:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/CP046319.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/GPM1643ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046319.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046319.scexe"],"md5sum":"109a6786c3ac21df854fd0c817137be1","name":"firmware-hdd-35fd24601f-HPD4-1.1.x86_64.rpm","release":"2020-12-13T16:30:08","revision":"0","sha1sum":"7b9b76ee79ac9673dcafdf455615daae71830504","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"c4ef0470aa934a20948f1a88d8eff26d","version":"a30b47fdbdc3487495db0c50e203f765"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T18:27:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to&nbsp;open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5432645","datemodified":"2020-12-13T13:23:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/CP045426.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/SMBPNSD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045426.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045426.scexe"],"md5sum":"8418312c9f6c19e39959341d29fd7a78","name":"firmware-hdd-b85516c7d2-HPD3-5.1.x86_64.rpm","release":"2020-12-13T13:12:05","revision":"0","sha1sum":"b8acfe789012baddb4c43fa4965ed597546b25cf","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"94af0b81860b4d31a8cc9f27961f4ea0","version":"9046bf69793d4c4d800d1fe2e3e5e49a"},"installation":{"command":"CP040343.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2016を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1613208","datemodified":"2020-06-12T11:05:50","file_list":["bepnic.dll","bepnic.rtf","cp044541.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"15cebde2a9436105658e4a57e87db28e","name":"cp044541.exe","release":"2020-06-12T10:52:05","revision":"0","sha1sum":"2bfc995dcd8113e38aff799c73cda3d66774cee5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"a0c7bf6781ed49d0a1fa08387a0fba69","version":"b0dcc06402cc405fa2ceff7f256a9fe3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Vmware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16856404","datemodified":"2021-01-28T10:40:41","file_list":["/CP045976_BUILD_5.data","/CP045976.vmexe","/CP045976.vmexe64","/CP045976.vmfile","/CP045976_VMw.zip","/CP045976.xml","/payload.json","/CP045976_VMw.zip/index.xml","/CP045976_VMw.zip/vendor-index.xml","/CP045976_VMw.zip/metadata.zip","/CP045976_VMw.zip/vib20/CP045976/HPE_bootbank_CP045976_HPD3.5-7.0.0.15843807.vib","/CP045976_VMw.zip/metadata.zip/vendor-index.xml","/CP045976_VMw.zip/metadata.zip/vmware.xml","/CP045976_VMw.zip/metadata.zip/vibs/CP045976--240085140877665927.xml","/CP045976_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045976_HPD3.5-7.0.0.15843807.xml"],"md5sum":"0a51e793c64e493931a98c0ee5576787","name":"CP045976.zip","release":"2021-01-28T10:38:04","revision":"0","sha1sum":"e0e751afa0d360ac6e2f2cf4f944d506734bc2e7","size":"16MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045976","version":"HPD3.5-7.0.0.15843807"}]}],"id":{"product":"d7a820130b1346d2a8d4377d479232cf","version":"f0c636a63ddf47d5bb58416fd9402259"},"installation":{"command":"CP040692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-30T09:48:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This release corrects logical block address mismatches that could results in partial or total data loss.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"542592","datemodified":"2019-09-27T00:11:23","file_list":["C240.dll","cannonlake-h.cat","CannonLake-HSystem.inf","CannonLake-HSystemThermal.inf","coffeelake.cat","CoffeelakeSystem.inf","cp039323.xml","cpqsetup.exe","instC240.dll","null_heci.cat","NULL_HECISystem.inf"],"md5sum":"ad4b8072b8aa7f80dce9aeb1525460e9","name":"cp039323.exe","release":"2019-10-10T00:00:00","revision":"1","sha1sum":"48c7cba57013d6632536472ad084b69e4e30d3e5","size":"529KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece19a3a3b"],"type_of_change":"0","version":"10.1.18015.8142"}],"id":{"product":"d6464fc039cd4a77b22febd8762dca03","version":"818111f98b2a4317ab7b4bcaaeaab74d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon E-2xxx Processor for Windows"},{"lang":"ja","x_late":"Windows用Intel Xeon E-2xxxプロセッサーの識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-12-05T20:19:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to match the latest version available from Intel. There are no functional differences between 10.1.17861.8101 and 10.1.18015.8142.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for the HPE ProLiant MicroServer Gen10 Plus Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"C240.dll","sw_key_expectedpath":"%ProgramFiles%\\Chipset software"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MK003840GWHTE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK003840GWHTEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows  (x64) - MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None.</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3095656","datemodified":"2020-12-16T16:02:58","file_list":["cp045561.xml","cpqsetup.exe","M51004G6.rel","payload.json","setup.dll"],"md5sum":"c74bce018d7da3e81c3f169d5d339116","name":"cp045561.exe","release":"2020-12-16T15:55:04","revision":"0","sha1sum":"71187e496e998b638025d8136db31238ffc3b4f1","size":"2MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"97296584dde64484806a51651325b7a3","version":"2b868f15d342409eb0ee7edf47cecb6b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK003840GWHTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:53:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the switch firmware on the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"可更新 HPE Express 托架支持交换卡上的交换机固件的补充更新/在线 ROM 刷新组件"},{"lang":"tw","x_late":"可升級 HPE Express 插槽啟用交換器卡的交換器韌體的補充更新/線上 ROM 更新智慧型元件"},{"lang":"ko","x_late":"HPE Express Bay Enablement Switch Card에서 스위치 펌웨어를 업그레이드하는 추가 업데이트/온라인 ROM 플래시 스마트 구성요소"},{"lang":"ja","x_late":"HPE Express Bay Enablement Switchカード上のスイッチファームウェアをアップグレードするサプリメンタルアップデート/オンラインROMフラッシュコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux (x64) &ndash; HPE Express Bay Enablement Switch Card<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78(B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"790499","datemodified":"2018-09-27T22:37:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/CP034965.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/flash","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/hdr_Pedali_Rev_0x02_Btlg_0x00.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/pedale-VP3-20171113-1.78-release.rbf","./usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-1.78-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP034965.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP034965.scexe"],"md5sum":"f4680b1dc270a860222aaabb9f0279d1","name":"firmware-smartarray-94189dca85-1.78-2.1.x86_64.rpm","release":"2018-09-28T03:35:03","revision":"0","sha1sum":"324898c33c640f791403632934f9203488a094d9","size":"771KB","target_guids":[],"type_of_change":"0","version":"1.78"}],"id":{"product":"25be2dadb23b40e0941b154b3b7febfe","version":"977a33d8eb4c4df4a8cfd6236507c0ba"},"installation":{"command":"CP034965.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:40px\"><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP034965.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-94189dca85-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP034965.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-94189dca85-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-94189dca85-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong><em>Additional Information:</em></strong></p>\n\n<p style=\"margin-left:40px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 Linux (x64) 的補充更新/線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성요소 - HPE Express Bay Enablement Switch Card"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Express Bay Enablement Switch Card"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-15T06:48:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Corrected the&nbsp;temperature status of Seagate NVMe hard drives.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.18.80"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.18.80"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.18.80"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.18.80"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.18.80"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.18.80"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.80.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.18.80"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4079376","datemodified":"2021-01-21T07:48:15","file_list":["cp044815.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.18.80.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"138854bc9b9a47c38fcf2e4bea884ca5","name":"cp044815.exe","release":"2021-01-21T07:38:08","revision":"0","sha1sum":"16efb2af16d651a2df6d4e7e6b5555f3388ce7e1","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"1e10e20d274448bb9d2d1625880b482d","version":"7606946689014fc39e6514fc86e53843"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects the display problem of the adapter name under RBSU.</li>\n\t<li>This products corrects some issues about the thermal reporting and temperature threadshold control of the adapter.</li>\n\t<li>This product addresses an issue where unexpected UMCE(Uncorrectable Machine Check Exception) appeared when powering on the system with NPAR(Network Partitioning) enabled.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue that platform would be randomly waked up by WOL packet.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD Flash Component for&nbsp;Windows (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:<br />\n&nbsp; &nbsp;</strong>&nbsp; Added support for Windows Server 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5036712","datemodified":"2021-01-25T05:51:26","file_list":["cp044275.xml","cpqsetup.exe","HPS1.rel","payload.json","setup.dll"],"md5sum":"db2382541736ea61b3e198b4328263fd","name":"cp044275.exe","release":"2021-01-25T05:39:04","revision":"0","sha1sum":"a703df54098da8dfa227ee92f6714957cbfd603d","size":"4MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1"}],"id":{"product":"81163fed551c4f30a0af9ef8c5746c3e","version":"df23189b2ab04d22a419c5d992c75d26"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-29T13:52:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5101455","datemodified":"2020-12-13T16:38:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/CP044847.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/G1633LD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044847.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044847.scexe"],"md5sum":"bf7b5a315451c9fa2188d6641ce4c4b4","name":"firmware-hdd-2eb810cdd7-HPD8-3.1.x86_64.rpm","release":"2020-12-13T16:27:04","revision":"0","sha1sum":"866bdad6627d73fd577563aae0cea1728f017b06","size":"4MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"a27996e3432942ccb8c76d5fed9fc9b4","version":"0294ab77ad214079a7f2a7d17ea43ff1"},"installation":{"command":"CP042627.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-13T10:48:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"11661161","datemodified":"2021-01-08T13:43:17","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"5c458cc55ff23e64223c4000cf79363e","name":"qlgc-fastlinq-kmp-default-8.55.5.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-08T13:19:08","revision":"0","sha1sum":"cea8dab602f5ae7fadd51e4957a9d58f9712e10d","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.5.0-1"},{"bytes":"11348068","datemodified":"2021-01-08T13:51:25","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/4.12.14-94.41-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"8961315e32601c6a24270e40bd4ddef2","name":"qlgc-fastlinq-kmp-default-8.55.5.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-08T13:19:08","revision":"0","sha1sum":"244729594dd3a619d54dd2eaaf775394fa8e329e","size":"10MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.5.0-1"}],"id":{"product":"beee944cb2a04bc7ba023dbf3bec720d","version":"3c55522e65bb404894d35ae14bf70587"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</li>\n\t<li>This product now adds PCIe Advanced Error Recovery (AER) support</li>\n\t<li>This product now supports RoCE bonding mode</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which system crash after unloading and reloading only roce driver</li>\n\t<li>This product corrects an issue which VF RDMA system crash in overnight reboot test on multiple VMs</li>\n\t<li>This product corrects an issue which VMs crash randomly upon advanced property disable/enable with Max VFs enumerated on all PFs</li>\n\t<li>This product corrects an issue which iSCSI BFS system fails to reboot if one port is down and reboot is attempted</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 8 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、Red Hat Enterprise Linux 8（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"986585","datemodified":"2020-11-18T10:01:51","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hpdsa","./lib/modules/4.18.0-193.el8.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"79b347ecd6db16367d92c27f4ea442ab","name":"kmod-hpdsa-1.2.10-185.rhel8u2.x86_64.rpm","release":"2020-11-18T09:49:04","revision":"0","sha1sum":"5ceb632b756cfe1883f8e587ca663a17709d3153","size":"963KB","target_guids":[],"type_of_change":"1","version":"1.2.10-185"},{"bytes":"986590","datemodified":"2020-11-18T09:56:53","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hpdsa","./lib/modules/4.18.0-240.el8.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"3547a80f8f426cbcf2aa7816cd0672d8","name":"kmod-hpdsa-1.2.10-185.rhel8u3.x86_64.rpm","release":"2020-11-18T09:49:04","revision":"0","sha1sum":"19dc1e6d2ec9ed9a986f07880d2bd5f4ceb1b04c","size":"963KB","target_guids":[],"type_of_change":"1","version":"1.2.10-185"}],"id":{"product":"791b93a05ce5422ca9f4427d20cc71b3","version":"a3e15d3bd3614253a996732879c9cd2d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\">&nbsp;</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"> </p>\n\n<p dir=\"ltr\"><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for Red Hat Enterprise Linux 8 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8（64-bit）用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T15:09:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added Support for Red Hat Enterprise Linux 8.2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Support for Red Hat Enterprise Linux 8.3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含 Emulex 光纖通道主機匯流排配接卡的 Windows 64 位元作業系統上提供對 Smart SAN 的支援套件。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Windows 64 bit operating systems."},{"lang":"ko","x_late":"이 패키지에는 Windows 64 비트 운영 체제에서 Emulex 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Windows 64 位操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、Windows 64ビット オペレーティングシステムでEmulex ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1618960","datemodified":"2020-05-11T09:19:15","file_list":["cp042255.xml","cpqsetup.exe","cp_data.xml","ElxSmartSANInstaller.dll","ELXSMARTSANVer.exe","esmartsan_cfg_cn.xml","esmartsan_cfg_en.xml","esmartsan_cfg_ja.xml","get_ss_status.bat","SmartSAN_Readme.txt","smartsan_x64.exe","ss_disable.bat","ss_enable.bat"],"md5sum":"c2167df0d40f1d4bebf64bd5c9163085","name":"cp042255.exe","release":"2020-05-11T09:16:05","revision":"0","sha1sum":"2df49746c00c2592d4d5a0ef3458613b9d931476","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"cdb3eb30e49445858807ae13ca01829a","version":"c6da56793b454760ac679546e7c3d11a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>For detailed information about configurable components, see the <em>Smart Update Manager User Guide </em>at <a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>.</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>これは構成可能コンポーネントです。  Smart SAN 機能を有効/無効にするための構成ファイルが必要です。  構成を実行できない場合、Smart SANの現状が記載され、実行が完了します。  それ以上の処置は不要です。</p>\n\n<p>構成コンポーネントの詳細については、<a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>の『<em>Smart Update Manager User Guide（Smart Update Managerユーザーガイド）</em>』を参照してください。</p>\n\n<p><strong>ProLiant の HPE サービス パックの外部コンポーネントの実行</strong>:</p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>[インストール]ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE Emulex SmartSAN 啟用套件適用於 Windows 64 位元作業系統"},{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Windows 64 bit operating systems"},{"lang":"ko","x_late":"HPE Emulex SmartSAN Enablement 키트에 대 한 Windows 64 비트 운영 체제"},{"lang":"cn","x_late":"HPE Emulex SmartSAN Enablement 套件适用于 Windows 64 位操作系统"},{"lang":"ja","x_late":"HPE Emulex Smart SAN イネーブルメントキット（Windows 64 ビットオペレーティングシステム）"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"338F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c338f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-20T05:30:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ELXSMARTSANVer.exe","sw_key_expectedpath":"%systemdrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1431504","datemodified":"2021-01-08T21:58:37","file_list":["cp045022.xml","cpqsetup.exe","cp_data.xml","iavf65.cat","iavf65.din","iavf65.inf","iavf65.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"64e0dd8d85aa685c68ac429cdcac00a6","name":"cp045022.exe","release":"2021-01-08T21:44:08","revision":"0","sha1sum":"97bff5c415ef119df3ae9a91efd46e7b229b72c2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b976669"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"49293a72024f46b59ade80ad47b20a00","version":"9ef815b7c028464e95680e9f66e2e480"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel iavf Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1889","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-188980860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1889","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"iavf655.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.7 Mellanox Ethernet driver for ConnectX-3(Pro) devices"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1321287","datemodified":"2020-11-24T07:55:38","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip","/cp046262.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-core-681000306.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-en-914539524.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-rdma-1057846885.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_en-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_rdma-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_core-3.17.70.1.xml"],"md5sum":"2298b30f04857c03d31e64ce539c1a80","name":"cp046262.zip","release":"2020-11-24T07:53:05","revision":"0","sha1sum":"9e2127c88c3d08bb5f8425c729ea6d564b6a703a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-en","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-rdma","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-core","version":"3.17.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"5174bf3a7a274551a9858fbcf75b37fb","version":"b26f87fc452c4998972983352fad588a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"nmlx4_en driver component for VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>No Fixes are included in version 3.17.70.1:</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-en:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-core:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18568041","datemodified":"2021-01-28T06:18:07","file_list":["/CP045633_BUILD_3.data","/CP045633.vmexe","/CP045633.vmexe64","/CP045633.vmfile","/CP045633_VMw.zip","/CP045633.xml","/payload.json","/CP045633_VMw.zip/index.xml","/CP045633_VMw.zip/vendor-index.xml","/CP045633_VMw.zip/metadata.zip","/CP045633_VMw.zip/vib20/CP045633/HPE_bootbank_CP045633_HPD1.3-7.0.0.15843807.vib","/CP045633_VMw.zip/metadata.zip/vendor-index.xml","/CP045633_VMw.zip/metadata.zip/vmware.xml","/CP045633_VMw.zip/metadata.zip/vibs/CP045633-2782615932811677911.xml","/CP045633_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045633_HPD1.3-7.0.0.15843807.xml"],"md5sum":"b5c04b9f4ec2b571193861a6f828c123","name":"CP045633.zip","release":"2021-01-28T06:14:04","revision":"0","sha1sum":"01aee5e2feb6b8f3cb8bd919b5f6ff98960a4744","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP045633","version":"HPD1.3-7.0.0.15843807"}]}],"id":{"product":"787f189347ac420fbe52f5e6292d569d","version":"ed2ae5ca86164ade8e2379e617abbc59"},"installation":{"command":"CP041492.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:36:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6Dx-rel-22_29_1016-MCX623106AS-CDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101D15B30042","Version":"22.29.1016"},{"DeviceName":"Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6Dx-rel-22_29_1016-MCX623105AS-VDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101D15B30040","Version":"22.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE and HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter firmware on Linux Operating Systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (P25960-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000437</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE (P10180-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000435</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"6541010","datemodified":"2021-01-27T09:06:51","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/CP044272.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/nic_fw/fw-ConnectX6Dx-rel-22_29_1016-MCX623105AS-VDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/nic_fw/fw-ConnectX6Dx-rel-22_29_1016-MCX623106AS-CDA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-nic-mft-1.0.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044272.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044272.scexe"],"md5sum":"4de81caa9499c6f0c535325dbe12926a","name":"firmware-nic-mellanox-nic-mft-1.0.3-1.1.x86_64.rpm","release":"2021-01-27T09:01:33","revision":"0","sha1sum":"3f74ce3debd015225db3b95c998912dca07059cd","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15B3-101D15B30042","a6b1a447-382a-5a4f-15B3-101D15B30040"],"type_of_change":"1","version":"1.0.3"}],"id":{"product":"aca57e96900e407ab0d44207053f1c1c","version":"f1417dacfb8740b78afdd26388304b5d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox ConnectX6Dx Open Ethernet cards"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-28T09:22:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device&nbsp;is updated to 22.27.6008:</strong></p>\n\n<p>P25960-B21 (HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes in version 22.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Spectrum-3: 30.2007.1142</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Spectrum-2: 29.2007.1142</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Switch SDK: 4.4.0920</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;SONiC/SAI: 201911</li>\n\t\t<li>&nbsp;&nbsp; &nbsp;ConnectX-6 Dx: 22.27.2008</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; *Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link speeds.</p>\n\n<ul>\n\t<li>Programmable Congestion Control (PCC) is at GA level.</li>\n\t<li>Enabled TLS offload v1.3 with key size 256.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been resolved in firmware version 22.27.6008:</strong></p>\n\n<ul>\n\t<li>Encapsulated RoCE traffic to drop when IB padding was required.</li>\n\t<li>PortXmitWait HW counter to count when not expected due to an inaccuracy in the counter.</li>\n\t<li>On dual-port device after Rx buffer modification the Physical Function on the second port got restored although no expected. &nbsp;The Rx buffer changes when all Physical Functions resets over one port (through reboot /driver restart / FLR) while there were active Physical Functions over the second port.</li>\n\t<li>Previous Shared Buffer modifications being overrun after performing Shared Buffer modifications such as SBPR, SBPM, SBCM, the PFCC Flow Control).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is updated to 22.29.1016:</strong></p>\n\n<p>&nbsp;</p>\n\n<p>P25960-B21 (HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter)</p>\n\n<p>P10180-B21 (Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes in version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n</ul>\n\n<ul>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Optimized vDPA performance for PPS in scalability of up to 127 devices per port.</li>\n\t<li>When using a Multi-Host device, the firmware can now discover who is the external SmartNIC host (the Embedded CPU PF (ECPF) ) with the highest index that is responsible for performing offload activities to the adapter card.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Eye-Opening: supported only when using NRZ signal. (Beta)</li>\n\t<li>Option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order. To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command and set DPP relevant attributes.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>Error statistics and reporting for vDPA.</li>\n\t<li>IPv6 TSO offload.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been resolved in firmware version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Traffic for virtio hardware offload solution was prevented from &quot;iperf3&quot; in Windows Operating System.</li>\n\t<li>Traffic for virtio hardware offload solution was prevented from &quot;iperf3 -i 512&quot;.</li>\n\t<li>The struct virtio_net_hdr was not set properly by the virtio hardware offload solution. The following message appeared in dmesg during traffic: &quot;bad gso: type xx, size: xx&quot;.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) might had taken longer than that of when MKEY_BY_NAME was disabled.</li>\n\t<li>TCP/IP traffic received by the guest kernel with version higher than 4.10 were&nbsp;unstable because of corrupted GSO header. The following message could be seen from dmegs: &quot;bad gso: type: xx, size: xxxx&quot;.</li>\n\t<li>Enabling the RoCE Accelerator capability resulted in low performance<br />\n\tNote:&nbsp;The fix is available when all ports are set as Ethernet.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 System -&nbsp;SAS Expander</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.00 (E)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00 (D)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3491888","datemodified":"2018-09-26T20:08:51","file_list":["cp037691.xml","cpqsetup.exe","firmware-Release-1.00-build-000.bin.fw","setup.dll"],"md5sum":"3f12ff5e5a2f2e86b21ad1f302af819a","name":"cp037691.exe","release":"2018-09-27T00:55:04","revision":"0","sha1sum":"5dc22a2da1a4cebdd1ae9167669d1df32a16607f","size":"3MB","target_guids":[],"type_of_change":"1","version":"1.00"}],"id":{"product":"6f346518c20d40dba8036f1e105d5ddf","version":"41d152c1a1f540aaa5fd9f4226274120"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.bat スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 System - SAS Expander"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Apollo 2000 System - SASエキスパンダー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-25T19:46:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added HPE Digital Signature</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE SNMP Agents (hp-snmp-agents) is a collection  of SNMP  protocol based agents  and tools which enables monitoring of fans, power supplies, temperature sensors and other management events via SNMP. It also provides the following: Foundation and Server agents, Storage Subsystem agents, Network Subsystem agents, the SNMP Dynamically Loaded Module, and the web support applications."},{"lang":"ja","x_late":"HPE SNMPエージェント（hp-snmp-agents）は、ファン、電源、温度センサー、およびその他SNMP経由の管理イベントの監視を可能にするSNMPプロトコルベースのエージェントとツールを集めたものです。同様に、以下を提供します。FoundationおよびServerエージェント、Storage Subsystemエージェント、Network Subsystemエージェント、SNMP動的ロードモジュール、およびWebサポートアプリケーション。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"1382063","datemodified":"2021-03-22T15:57:38","file_list":["./etc/hp-snmp-agents.conf","./etc/init.d/hp-snmp-agents","./etc/logrotate.d/hp-snmp-agents","./opt/hp/hp-snmp-agents","./opt/hp/hp-snmp-agents/addons","./opt/hp/hp-snmp-agents/cma.conf","./opt/hp/hp-snmp-agents/hp-snmp-agents.license","./opt/hp/hp-snmp-agents/hp-snmp-agents.manifest","./opt/hp/hp-snmp-agents/hp-snmp-agents.rebuild.spec","./opt/hp/hp-snmp-agents/hprpm.xpm","./opt/hp/hp-snmp-agents/mibs","./opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibdef","./opt/hp/hp-snmp-agents/mibs/cmaobjects.mibver","./opt/hp/hp-snmp-agents/mibs/cmaobjects.regmib","./opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf","./opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf","./opt/hp/hp-snmp-agents/nic","./opt/hp/hp-snmp-agents/nic/bin","./opt/hp/hp-snmp-agents/nic/bin/cmanicd","./opt/hp/hp-snmp-agents/nic/bin/hpetfe","./opt/hp/hp-snmp-agents/nic/etc","./opt/hp/hp-snmp-agents/nic/etc/HPcmanic.pp","./opt/hp/hp-snmp-agents/nic/etc/cmanic","./opt/hp/hp-snmp-agents/nic/etc/cmanicd","./opt/hp/hp-snmp-agents/rebuild","./opt/hp/hp-snmp-agents/server","./opt/hp/hp-snmp-agents/server/bin","./opt/hp/hp-snmp-agents/server/bin/cmahealthd","./opt/hp/hp-snmp-agents/server/bin/cmahostd","./opt/hp/hp-snmp-agents/server/bin/cmapeerd","./opt/hp/hp-snmp-agents/server/bin/cmaperfd","./opt/hp/hp-snmp-agents/server/bin/cmasm2d","./opt/hp/hp-snmp-agents/server/bin/cmastdeqd","./opt/hp/hp-snmp-agents/server/bin/cmathreshd","./opt/hp/hp-snmp-agents/server/bin/distro-id.sh","./opt/hp/hp-snmp-agents/server/etc","./opt/hp/hp-snmp-agents/server/etc/cmad","./opt/hp/hp-snmp-agents/server/etc/cmahealthd","./opt/hp/hp-snmp-agents/server/etc/cmahostd","./opt/hp/hp-snmp-agents/server/etc/cmapeerd","./opt/hp/hp-snmp-agents/server/etc/cmaperfd","./opt/hp/hp-snmp-agents/server/etc/cmarackd","./opt/hp/hp-snmp-agents/server/etc/cmasm2d","./opt/hp/hp-snmp-agents/server/etc/cmastdeqd","./opt/hp/hp-snmp-agents/server/etc/cmathreshd","./opt/hp/hp-snmp-agents/server/etc/cpqbssa.txt","./opt/hp/hp-snmp-agents/server/etc/cpqriisd","./opt/hp/hp-snmp-agents/share","./opt/hp/hp-snmp-agents/share/doc","./opt/hp/hp-snmp-agents/share/doc/HP_SNMP_Trap_Guide.txt","./opt/hp/hp-snmp-agents/storage","./opt/hp/hp-snmp-agents/storage/bin","./opt/hp/hp-snmp-agents/storage/bin/cmaeventd","./opt/hp/hp-snmp-agents/storage/bin/cmafcad","./opt/hp/hp-snmp-agents/storage/bin/cmaidad","./opt/hp/hp-snmp-agents/storage/bin/cmaided","./opt/hp/hp-snmp-agents/storage/bin/cmasasd","./opt/hp/hp-snmp-agents/storage/bin/cmascsid","./opt/hp/hp-snmp-agents/storage/bin/libcpqimgr-x86_64.so","./opt/hp/hp-snmp-agents/storage/etc","./opt/hp/hp-snmp-agents/storage/etc/cmaeventd","./opt/hp/hp-snmp-agents/storage/etc/cmafcad","./opt/hp/hp-snmp-agents/storage/etc/cmaidad","./opt/hp/hp-snmp-agents/storage/etc/cmaided","./opt/hp/hp-snmp-agents/storage/etc/cmasasd","./opt/hp/hp-snmp-agents/storage/etc/cmascsid","./opt/hp/hp-snmp-agents/storage/etc/cmastorobjects.conf","./opt/hp/hp-snmp-agents/utils","./opt/hp/hp-snmp-agents/utils/usb-device.sh","./opt/hp/hp-snmp-agents/webagent","./opt/hp/hp-snmp-agents/webagent/csginkgo","./sbin/hpsnmpconfig","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/e8db9158460525fd946ad75d2867c352a5aa4d","./usr/lib/.build-id/12","./usr/lib/.build-id/12/e9d5b0020e309680faa1b2ffcced699cb95c62","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/778e28d7f7cfec635547d35ca5c0250e634379","./usr/lib/.build-id/42","./usr/lib/.build-id/42/edb3efe7004ad789541e6fcc809b0413c71bee","./usr/lib/.build-id/4a","./usr/lib/.build-id/4a/3ccd51d7c616ab5570aa7872bf141f2fc572f4","./usr/lib/.build-id/63","./usr/lib/.build-id/63/41e2c139b7ba5aa67c6868c2a8ea3c8f485c48","./usr/lib/.build-id/77","./usr/lib/.build-id/77/92ab98faffa002b6ed1ce7ce9ff89a7a497d04","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/06003638bed4e4e15389cbd41f9c8b58f29ba5","./usr/lib/.build-id/a6","./usr/lib/.build-id/a6/a70335f0151efa10cc428f37f5b10d26a22601","./usr/lib/.build-id/ab","./usr/lib/.build-id/ab/98dc6b61f638195f316f9d7e3e7351f3f8a077","./usr/lib/.build-id/ad","./usr/lib/.build-id/ad/fcd2fbf26f6c1926c6825044c35d5e8a0f5c83","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/4a71cc016a20dce246b8213d8d13e0124750e2","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/f470b9c1c75fc7216fddfafed463c6a3b93cd3","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/b75c421c63f028e8c15441c2150268f5d6b7e0","./usr/lib/.build-id/cf","./usr/lib/.build-id/cf/bbc3c17e0f5fd36ff9fbfc513b0551ebdc8669","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/ec0beab18f87c425306c643174efa4dbfc1321","./usr/lib/.build-id/d5","./usr/lib/.build-id/d5/b1b448822cf721ec14a1bd7a7414b8240c1639","./usr/lib/.build-id/df","./usr/lib/.build-id/df/5d9abcb65f182a296cc8061f52db913871facc","./usr/lib/.build-id/ff","./usr/lib/.build-id/ff/5480eb3dac78c8b10a3b6bbc5f7b69e91de089","./usr/lib64/libcmaX64.so","./usr/lib64/libcmaX64.so.1","./usr/lib64/libcmaX64.so.1.0","./usr/lib64/libcmacommon64.so","./usr/lib64/libcmacommon64.so.1","./usr/lib64/libcmacommon64.so.1.0","./usr/lib64/libcmaconf64.so","./usr/lib64/libcmaconf64.so.1","./usr/lib64/libcmaconf64.so.1.0","./usr/lib64/libcmapeer64.so","./usr/lib64/libcmapeer64.so.1","./usr/lib64/libcmapeer64.so.1.0","./usr/share/man/man4/hp-snmp-agents.4.gz","./usr/share/man/man8/cmanicd.8.gz","./usr/share/smartupdate/hp-snmp-agents/component.xml","./var/log/hp-snmp-agents","./var/spool/compaq"],"md5sum":"9215251726b8a96420fd6e3e2a681e6d","name":"hp-snmp-agents-10.92-679.6.rhel8.x86_64.rpm","release":"2021-03-22T15:51:05","revision":"0","sha1sum":"fa0a9b468cdbe5c52362204552ccf0cf1958b847","size":"1MB","target_guids":[],"type_of_change":"1","version":"10.9.2"}],"id":{"product":"ea9fa4d5a6f7491799a049be7661a52e","version":"77d443ac3c09432f95728c6c09a9b48d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</P>\n<P>To install the package, type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>rpm -ivh hp-snmp-agents-&lt;version&gt;.rpm</I></B></P>\n<P>To check whether the package is loaded properly type: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>Additional help is available by typing: </P>\n<P>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<B><I>man hp-snmp-agents</I></B></P>"},{"lang":"ja","x_late":"<P>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</P>\n<P>パッケージをインストールするには、次のようにタイプします。</P>\n<P>         <B><I>rpm -ivh hp-snmp-agents-<version>.rpm</I></B></P>\n<P>パッケージが正しくロードされているか、以下をタイプして確認します。</P>\n<P>         <B><I>/etc/init.d/hp-snmp-agents status</I></B></P>\n<P>以下のコマンドを実行してヘルプを参照してください。</P>\n<P>         <B><I>man hp-snmp-agents</I></B></P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SNMP Agents for Red Hat Enterprise Linux 8 Server"},{"lang":"ja","x_late":"HPE SNMPエージェントfor Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-07T14:18:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>&nbsp;the hp-snmp-agents service version 10.9.0 on an HPE ProLiant Gen9 Server or an HPE Synergy Gen9 Compute Node may experience a segfault after installation or restart of the hp-snmp-agents service. cmahostd or cmapeerd process will be killed after the segfault.&nbsp; Pleaer review customer advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00098957en_us\" style=\"color:#0563c1; text-decoration:underline\">a00098957en_us</a>&nbsp;for additional details.</li>\n\t<li>The OS version reported by hp-snmp-agents reported a&nbsp;mismatch with the newer Linux OS distros. i.e., &quot;SUSE Linux Enterprise Server 12&quot; v.s &quot;SUSE Linux Enterprise Server 12 SP5&quot;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed issue where the HPE Synergy 3820C 10/20Gb Converged Network Adapter was showing not supported</li>\n\t<li>Corrected invalid utf8mb4 char in database</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"}],"sw_keys":[{"name":"hp-snmp-agents","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045271.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2627680","datemodified":"2020-11-02T08:42:08","file_list":["cp045271.compsig","cp045271.zip","cp045274.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"048b1760c4f3c7bc2f0f6cf4416625df","name":"cp045274.exe","release":"2020-11-02T08:40:14","revision":"0","sha1sum":"4df8da1d2aa484d4f466252a447cc983bd29a4f5","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"8bd617958fd64494b0066602dc57ff65","version":"bb8d7bc69f644c5ca40f6d13006f562a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T02:36:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB012000GWDFE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n  Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4117256","datemodified":"2020-12-17T05:26:13","file_list":["cp045529.xml","cpqsetup.exe","HLEAHasseFG2.rel","payload.json","setup.dll"],"md5sum":"04fdf86e9132a7ace66b9ebf4996934c","name":"cp045529.exe","release":"2020-12-17T05:18:04","revision":"0","sha1sum":"563aaf3b2de38cbdba0ecffaf798cb33151fadbd","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"2","version":"HPG2"}],"id":{"product":"230d4b31fe374aebb4d538e99b933aee","version":"e9286289c12c40a68271ced06f704b00"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:42:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue during unaligned write commands, found in supplier ongoing lab testing.Includes additional fixes to improve error handling and reliability.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"DL20ML30Gen10SPS_05.01.04.208.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2001308","datemodified":"2020-11-02T08:52:35","file_list":["DL20ML30Gen10SPS_05.01.04.208.signed.bin","DL20ML30Gen10SPS_05.01.04.208.xml","payload.json"],"md5sum":"7d68f2c85445b595132657d82ee7c658","name":"DL20ML30Gen10SPS_05.01.04.208.fwpkg","release":"2020-11-02T08:51:14","revision":"0","sha1sum":"b8e9ff7252dc003ee75fdfc39b0cb736c4e985bb","size":"1MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"aacf76bfa7674de086e8a84063eadb98","version":"b5e8845268d142649c1270f9cec85f2c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T02:33:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2126442","datemodified":"2021-02-25T07:55:23","file_list":["/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip","/cp044633.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/vendor-index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/vib20/vmware-storcli64/BCM_bootbank_vmware-storcli64_007.1616.0000.0000-01.vib","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vendor-index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vmware.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vibs/vmware-storcli64-471654706444394320.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/bulletins/BCM-vmware-storcli64_007.1616.0000.0000-01.xml"],"md5sum":"833553f49b2b206dcb914ea05217da9c","name":"cp044633.zip","release":"2021-02-25T07:54:04","revision":"0","sha1sum":"19d5b3e94f8e601b2ffc55d55c6cef65f13dca63","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f161a38","20a6e8e4-bf33-4c71-a6bf-d9ec466b4ce5"],"type_of_change":"1","version":"2021.04.00","vib_list":[{"name":"vmware-storcli64","version":"007.1616.0000.0000-01"}]}],"id":{"product":"227d96d8e01b420b8686e88babe12d3a","version":"45cf739dde494438b0242c6056f54af4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 7.0 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -d=&lt;path&gt;&lt;componet_bundle&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-22T13:17:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Supported on ESXi OS 7.0 64 bit</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"BCM-vmware-storcli64:007.1616.0000.0000-01","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"vmware-storcli64:007.1616.0000.0000-01","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4672488","datemodified":"2020-12-13T15:55:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/4IDMHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/CP045469.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045469.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045469.scexe"],"md5sum":"8d490e6a44a4454820b54da29ca4c4b0","name":"firmware-hdd-b7eb905efe-HPG1-6.1.x86_64.rpm","release":"2020-12-13T15:42:09","revision":"0","sha1sum":"62910d4922194d0f6d5e0eb05bea91a54de91256","size":"4MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"221cbeaf26c845fea3e521bf7ae66fa1","version":"0e809a7618ca42ec915330863f0d8d77"},"installation":{"command":"CP040348.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VR000150GWEPP and VR000480GWEPR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times. </li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1485428","datemodified":"2021-01-09T01:59:41","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-iavf","./lib/modules/4.12.14-120-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"fae19dfa497fe779c2f98cb08bc80eb6","name":"hp-iavf-kmp-default-4.0.2_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T01:53:05","revision":"0","sha1sum":"c5a97e55a5d304b118a75ebfa061949b08a11bfe","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.0.2-1"},{"bytes":"1429403","datemodified":"2021-01-09T02:03:27","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-iavf","./lib/modules/4.12.14-94.41-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"9b9afe5666855183d93cd5f1e7a6b8a2","name":"hp-iavf-kmp-default-4.0.2_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T01:53:05","revision":"0","sha1sum":"2fa082b77c63ff28ad230e32b298b5f68a6d4ddf","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.0.2-1"}],"id":{"product":"e05dec268daa4148be358b19a3214eed","version":"39ea1c4e7b8c4e2a988e3c31195409e1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20855863","datemodified":"2021-01-28T22:26:47","file_list":["/CP045709_BUILD_4.data","/CP045709.vmexe","/CP045709.vmexe64","/CP045709.vmfile","/CP045709_VMw.zip","/CP045709.xml","/payload.json","/CP045709_VMw.zip/index.xml","/CP045709_VMw.zip/vendor-index.xml","/CP045709_VMw.zip/metadata.zip","/CP045709_VMw.zip/vib20/CP045709/HPE_bootbank_CP045709_HPK3.4-7.0.0.15843807.vib","/CP045709_VMw.zip/metadata.zip/vendor-index.xml","/CP045709_VMw.zip/metadata.zip/vmware.xml","/CP045709_VMw.zip/metadata.zip/vibs/CP045709-3199290604719472473.xml","/CP045709_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045709_HPK3.4-7.0.0.15843807.xml"],"md5sum":"14af23c046cd93df3dc1983ee7b6d3ee","name":"CP045709.zip","release":"2021-01-28T22:24:04","revision":"0","sha1sum":"fd9f97b0f69e0fbb53921976380bbdcc2ccd36e5","size":"19MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP045709","version":"HPK3.4-7.0.0.15843807"}]}],"id":{"product":"a2580f8b900b4c35b050bbb3d0fe3010","version":"32c1c94be67140aa8a3b3c07a1e2b751"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:40:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue where the SSID was not programmed correctly to the drive. This may cause issues with the drive not being identified correctly in the Integrated Lights Out Utility.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。 このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。\nerrataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。  だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。  そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"608320","datemodified":"2021-02-09T13:50:57","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/smartpqi","./lib/modules/3.10.0-1127.el7.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"b79d905968efe80b85ac69e789e68230","name":"kmod-smartpqi-2.1.8-040.rhel7u8.x86_64.rpm","release":"2021-02-09T13:42:04","revision":"0","sha1sum":"189b00b9ea9ad5cd32545dc8de093bffa9e6d5bf","size":"594KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.8-040"},{"bytes":"608835","datemodified":"2021-02-09T13:49:32","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/smartpqi","./lib/modules/3.10.0-1160.el7.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"9095d5e707bff2389d2e830a491b741d","name":"kmod-smartpqi-2.1.8-040.rhel7u9.x86_64.rpm","release":"2021-02-09T13:42:04","revision":"0","sha1sum":"dc6c59357cbb09aefacc75742412920b0fc48b42","size":"594KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.8-040"}],"id":{"product":"a25209e630db46018590185244995b68","version":"aa3c121500f245a983dc412fbf1b0956"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-&lt;version&gt;.rhel7&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel7&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-<version>.rhel7<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p> </p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-<version>.rhel7<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 7 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-03T21:44:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Red Hat Linux Enterprise 7 Update 9</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>-</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;6.88<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;6.60(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fix</strong><strong>ed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4805536","datemodified":"2019-08-08T19:27:26","file_list":["cp039995.xml","cpqsetup.exe","firmware_signed.bin.fw","setup.dll"],"md5sum":"26ea1c08bcdb8ef0547df414eafa22b9","name":"cp039995.exe","release":"2019-08-08T19:14:03","revision":"0","sha1sum":"55f024b36509b67ef995a6b1941523fa39798a6e","size":"4MB","target_guids":[],"type_of_change":"1","version":"7.00"}],"id":{"product":"abb94178152540d4b4597562d0b2a39f","version":"e72e09a823154db2bd8dc779aa2a7ff1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows（x64）- SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-29T18:57:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes the following Issues</p>\n\n<ul>\n\t<li>SATA drive could stop responding&nbsp; while on HBA mode when non-NCQ commands are executed</li>\n\t<li>Controller could stop responding when upgrading due to the DDR Cache Module exceeding its limitations</li>\n\t<li>SSD Cache module could become disable while upgrading FW</li>\n\t<li>Data from the HPE Smart Drive Backplane could potentially become corrupted if a non-HPE carrier is present</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Add optimization for the iLO communication interface in order to have a more effective mechanism to check for ownership of the communication buffer</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Occasionally&nbsp; the drive will not accept any IO&rsquo;s after running Sanitize command for a period of time due to the FW being out of sync with the drive during that time</li>\n\t<li>Non-HPE drives could report &ldquo;Task Set Full&rdquo; due to the drives reaching the qdepth limit during heavy workload</li>\n\t<li>Raid volume is not discovered due to a bad drive consuming two slots during hotplug</li>\n\t<li>Data could become inaccessible when upgrading from&nbsp;firmware versions prior to 4.5x</li>\n\t<li>The controller could stop responding when executing a SCSI verify command due to a CPU exception</li>\n\t<li>The system could stop communicating due to an I/O command timeout</li>\n\t<li>While on HBA mode, a drive could stop responding due to an early allocated buffer release</li>\n\t<li>A SAS drive WWN is reported inaccuratelyy due to an incorrect report causing the driver to be out of sync with the device</li>\n\t<li>If using a 4G module, the controller could stop responding due to the SSD Cache metadata exceeding its limits during a Backup</li>\n\t<li>SSD Smart Cache module become disabled due to a reduction in usable cache space</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5957488","datemodified":"2020-11-04T07:58:12","file_list":["P92_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046143.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"b0f6940b6c8318c1d92dd98089b764ea","name":"cp046143.exe","release":"2020-11-04T07:39:05","revision":"0","sha1sum":"c226eed6c2534262f2d5d6c467b3510e12cca31d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"bfbca72d042244cd96c184756848a501","version":"36adf493840742f0bc1ecd74c89b77db"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant ML350 Gen9（P92）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T05:24:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3281","Version":"1280A3"},{"DeviceName":"HPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3282","Version":"1280A3"},{"DeviceName":"HPE SN1000E 16Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E4","Version":"12.8.352.12"},{"DeviceName":"HPE SN1000E 16Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E5","Version":"12.8.352.12"},{"DeviceName":"HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197F","Version":"12.8.352.12"},{"DeviceName":"HPE  SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197E","Version":"12.8.352.12"},{"DeviceName":"HPE 84E 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C2238","Version":"1280A3"},{"DeviceName":"HPE SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200159000FB","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.352.12-1//firmware//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6555056","datemodified":"2021-01-29T06:37:01","file_list":["cp044732.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.352.12-1/boot/","elxflashStandalone-windows-12.8.352.12-1/boot/UU1280A3.PRG","elxflashStandalone-windows-12.8.352.12-1/firmware/","elxflashStandalone-windows-12.8.352.12-1/firmware/A12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/B12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/P12835212.grp","elxflashStandalone-windows-12.8.352.12-1/firmware/UD210X6.ALL","elxflashStandalone-windows-12.8.352.12-1/win/","elxflashStandalone-windows-12.8.352.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.352.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.352.12-1/win/x64/","elxflashStandalone-windows-12.8.352.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.352.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.352.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.352.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.352.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.352.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.352.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"77d06d4208058be9b77bece238f74913","name":"cp044732.exe","release":"2021-01-29T06:20:11","revision":"0","sha1sum":"e56763fb32363697a9083fca2224920653deee78","size":"6MB","target_guids":["a6b1a447-382a-5a4f-10DF-F100103C3281","a6b1a447-382a-5a4f-10DF-F100103C3282","a6b1a447-382a-5a4f-10DF-E200103C17E4","a6b1a447-382a-5a4f-10DF-E200103C17E5","a6b1a447-382a-5a4f-10DF-E200103C197F","a6b1a447-382a-5a4f-10DF-E200103C197E","a6b1a447-382a-5a4f-10DF-F100103C2238","a6b1a447-382a-5a4f-10DF-E200159000FB","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D6","a6b1a447-382a-5a4f-10DF-F400159002D5"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"b929c06b33df46a182acd3e907e0dc53","version":"c400015bffd441158c62d44eb4051232"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<br />\nダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server  2012R2/2016/2019 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp; have separate components to update fibre channel and converged network adapters.&nbsp;This is a fibre channel&nbsp;update component.</p>\n\n<p><strong>Contains:</strong></p>\n\n<p>32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16/32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>8 Gb HBA Standup firmware 2.10X6<br />\n8 Gb standup universal boot image 12.60a4(12.6.302.0 BIOS, 12.6.284.0 UEFI)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK003840GWSXLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4977448","datemodified":"2020-12-13T15:17:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/CP045461.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/M52004G2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045461.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045461.scexe"],"md5sum":"9515f5555c6326800926b6830566cb9d","name":"firmware-hdd-d1cf327bc4-HPG2-5.1.x86_64.rpm","release":"2020-12-13T15:05:05","revision":"0","sha1sum":"983731d960c5300c825774e2783c424b6fe8f618","size":"4MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"26ad6199e9ca4196942c2e37e82e08a2","version":"e1e7d54bccb84be59648ed6f023d2d16"},"installation":{"command":"CP040779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>BIOS A42_2.40_09_24_2020 needs iLO 5 v2.40 Pass 10 as the minimum supported version.</p>\n"}],"files":[{"bytes":"33587227","datemodified":"2021-02-25T07:03:50","file_list":["A42_2.40_02_23_2021.signed.flash","A42_2.40_02_23_2021.xml","payload.json"],"md5sum":"41ad33ef74e21c32dda30e73b962eb9f","name":"A42_2.40_02_23_2021.fwpkg","release":"2021-02-25T07:00:06","revision":"0","sha1sum":"aa7964b37ab564daa9652ce3fbb5947b4ab01e6d","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"a745e380a94147888b60792dcbb594a8","version":"9cc8f4cec0744039bffb010beb5e9f28"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-10T02:28:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Microsoft Windows Server 2012 R2 執行的 HPE Intel E1R Gigabit Ethernet NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2012 R2에서 실행되는 HPE Intel E1R 기가비트 이더넷 NIC용 드라이버가 들어 있습니다."},{"lang":"cn","x_late":"此组件包包含的驱动程序适用于在 Microsoft Windows Server 2012 R2 环境下运行的 HPE Intel E1R 千兆位以太网 NIC。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1187880","datemodified":"2021-01-09T06:01:56","file_list":["cp045119.xml","cpqsetup.exe","cp_data.xml","e1r64x64.cat","e1r64x64.din","e1r64x64.inf","e1r64x64.sys","e1rmsg.dll","install.xml","NicCo36.dll","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"11e3d593ef3bbec0b25bce6a2c0950ca","name":"cp045119.exe","release":"2021-01-09T05:47:06","revision":"0","sha1sum":"c1c1dca70fca9a137cebe7663685cc6c4098620f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7"],"type_of_change":"0","version":"12.14.8.5"}],"id":{"product":"e94f7a42aa22458dbfe70c776b04164a","version":"974e6b798a654efbbf9ed925a6f59a08"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為一個自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br><p>從該磁碟和目錄，執行下載的檔案。   <br><p>按一下 Install (安裝) 按鈕，以繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.   <br><p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br><p>在该硬盘目录中，执行下载的文件。   <br><p>点击“安装”按钮进行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。   <br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE Intel E1R 驅動程式 (適用於 Windows Server 2012 R2)"},{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2012 R2"},{"lang":"ko","x_late":"Windows Server 2012 R2용 HPE Intel E1R 드라이버"},{"lang":"cn","x_late":"用于 Windows Server 2012 R2 的 HPE Intel E1R 驱动程序"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"e1r64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK74H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3およびMZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>EPK74H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"7557736","datemodified":"2021-01-23T12:56:02","file_list":["cp046472.xml","cpqsetup.exe","EPK74H3Q.rel","payload.json","setup.dll"],"md5sum":"f718c1599d57fd615dba54ec6547b3c1","name":"cp046472.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"41e58569b72854db4acf12bce6241426ec905522","size":"7MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK74H3Q"}],"id":{"product":"99c23ff7c8d6427fabec401028b615d8","version":"72c2e075838b40f08ed07bf98b442459"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor Windows (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:06:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"49330752","datemodified":"2021-02-02T15:25:41","file_list":["cp046226.xml","cpqsetup.exe","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"md5sum":"731e24692aebc8a56eb7c32b62d66937","name":"cp046226.exe","release":"2021-02-02T15:23:06","revision":"0","sha1sum":"e6654c5d959137d56071b9b8553730641d1d282d","size":"47MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"type_of_change":"0","version":"7.16.16.0"}],"id":{"product":"d71ec216198e46cba0dfe25b58e109f0","version":"96c31c60fa0341638f946b3f78235de6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"},{"lang":"ja","x_late":"<p>HPE MRSAの古いバージョンがシステムにインストールされている場合、\"コントロールパネル ->プログラムのアンインストール\"からアンインストールを行った後に、\"LSA\"をアンインストールしてください。</p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator (HPE MRSA) for Windows 64-bit"},{"lang":"ja","x_late":"Windows 64-bit向けHPE MegaRAID Storage Administrator (HPE MRSA)"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-04T10:50:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Supports Gen10+ MegaRAID Controllers.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsa.exe","sw_key_expectedpath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GEXXV Drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB6000GEXXVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16851534","datemodified":"2021-01-28T11:39:52","file_list":["/CP045663_BUILD_4.data","/CP045663.vmexe","/CP045663.vmexe64","/CP045663.vmfile","/CP045663_VMw.zip","/CP045663.xml","/payload.json","/CP045663_VMw.zip/index.xml","/CP045663_VMw.zip/vendor-index.xml","/CP045663_VMw.zip/metadata.zip","/CP045663_VMw.zip/vib20/CP045663/HPE_bootbank_CP045663_HPG2.4-7.0.0.15843807.vib","/CP045663_VMw.zip/metadata.zip/vendor-index.xml","/CP045663_VMw.zip/metadata.zip/vmware.xml","/CP045663_VMw.zip/metadata.zip/vibs/CP045663--7597627278620322537.xml","/CP045663_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045663_HPG2.4-7.0.0.15843807.xml"],"md5sum":"162d60c39f2bee2537c701324c2c252b","name":"CP045663.zip","release":"2021-01-28T11:37:04","revision":"0","sha1sum":"065f7de3c4e985b7484485f3d06537e19bcfc04e","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045663","version":"HPG2.4-7.0.0.15843807"}]}],"id":{"product":"b85e73b81c5b414ba6a301b86f35ed46","version":"3be3dff59dac4a7da61b887c1d6c6438"},"installation":{"command":"CP040515.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:04:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD3"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP and EG001200JWJNQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18258492","datemodified":"2021-01-27T11:44:44","file_list":["/CP045607_BUILD_3.data","/CP045607.vmexe","/CP045607.vmexe64","/CP045607.vmfile","/CP045607_VMw.zip","/CP045607.xml","/payload.json","/CP045607_VMw.zip/index.xml","/CP045607_VMw.zip/vendor-index.xml","/CP045607_VMw.zip/metadata.zip","/CP045607_VMw.zip/vib20/CP045607/HPE_bootbank_CP045607_HPD3.3-7.0.0.15843807.vib","/CP045607_VMw.zip/metadata.zip/vendor-index.xml","/CP045607_VMw.zip/metadata.zip/vmware.xml","/CP045607_VMw.zip/metadata.zip/vibs/CP045607--7677514300082284780.xml","/CP045607_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045607_HPD3.3-7.0.0.15843807.xml"],"md5sum":"44bc03a6e9a3ebca09f62d4d3186fce7","name":"CP045607.zip","release":"2021-01-27T11:42:05","revision":"0","sha1sum":"99da1fb375b5a9cba1d5de5b83d8928ca0031dfa","size":"17MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045607","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"5829ee37bc994558baa6a98dd52b6154","version":"bc70e165b2234d7689e6544517edc4db"},"installation":{"command":"CP041692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:13:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;1.56(D)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"13759645","datemodified":"2018-12-13T06:48:02","file_list":["/CP038103.vmexe","/CP038103.vmfile","/CP038103.xml","/payload.json","/README.txt"],"md5sum":"c8ac24a4e5379a01c9e8bba4860a0a06","name":"CP038103.zip","release":"2018-12-13T12:28:04","revision":"0","sha1sum":"1d5b8634f2c3958124e78558bb54998a24ae5107","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56","vib_list":[]}],"id":{"product":"4c73b927073e4ea9b7b9d214d86c215b","version":"db137c88b05045ae9dc51920d767876b"},"installation":{"command":"CP038103.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB&nbsp; Key&nbsp;Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />\n<br />\n     オフライン（</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>）：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li><strong>SUM 8.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 45xx Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-12-15T07:45:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17550992","datemodified":"2021-01-27T20:39:50","file_list":["/CP045625_BUILD_3.data","/CP045625.vmexe","/CP045625.vmexe64","/CP045625.vmfile","/CP045625_VMw.zip","/CP045625.xml","/payload.json","/CP045625_VMw.zip/index.xml","/CP045625_VMw.zip/vendor-index.xml","/CP045625_VMw.zip/metadata.zip","/CP045625_VMw.zip/vib20/CP045625/HPE_bootbank_CP045625_HPD2.3-7.0.0.15843807.vib","/CP045625_VMw.zip/metadata.zip/vendor-index.xml","/CP045625_VMw.zip/metadata.zip/vmware.xml","/CP045625_VMw.zip/metadata.zip/vibs/CP045625--4000282247913405313.xml","/CP045625_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045625_HPD2.3-7.0.0.15843807.xml"],"md5sum":"bb91037be75a5918b7fc79a34ee1bdfb","name":"CP045625.zip","release":"2021-01-27T20:37:04","revision":"0","sha1sum":"d911c0afa7f31d6700be5b1260b49b815fac9c7a","size":"16MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045625","version":"HPD2.3-7.0.0.15843807"}]}],"id":{"product":"d54c971d2c3047569ed2e37939cd2848","version":"bb86ea5635d64545a1b84cce04e232ea"},"installation":{"command":"CP040645.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA および MO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:30:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含公用程式和二進位檔，可在 Linux 作業系統上升級僅 HPE Mellanox 乙太網路配接卡韌體。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Linux Operating Systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 HPE Mellanox 이더넷 전용 어댑터 펌웨어를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"此软件包含有用于升级在Linux操作系统下运行的仅使用太网适配器的HPE Mellanox的固件所需的实用程序和二进制程序。"},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"8328427","datemodified":"2021-01-19T08:12:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/CP045196.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.14-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045196.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045196.scexe"],"md5sum":"dc66d1ce846961752c9267d2c653965f","name":"firmware-nic-mellanox-ethernet-only-1.0.14-1.1.x86_64.rpm","release":"2021-01-19T08:07:08","revision":"0","sha1sum":"d223fddcf699dd58a21d2cf0a53b45e8ac5e00f6","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.14"}],"id":{"product":"5c045315a07d45779f552f6cb831a2b4","version":"39d674eb07b34ff394185e6972ccecc8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"線上韌體升級公用程式 (Linux x86_64)，僅適用於 HPE Mellanox 乙太網路配接卡"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters"},{"lang":"ko","x_late":"HPE Mellanox 이더넷 전용 어댑터의 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于仅使用太网适配器的HPE Mellanox的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.28.1016:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL&nbsp;and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4620323","datemodified":"2020-12-13T15:49:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/CP045464.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/GPM863G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045464.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045464.scexe"],"md5sum":"f53f98da1dc50dfb593bc6b6d2ff1aaf","name":"firmware-hdd-a2d4b5c742-HPG1-9.1.x86_64.rpm","release":"2020-12-13T15:37:04","revision":"0","sha1sum":"2ffea8ddd62c5ddd35e498acc16ec1338a6b3a8f","size":"4MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"149f4a8ca4634ca1990be51d125b79e4","version":"619a38a5800e45a59199272af6ae804a"},"installation":{"command":"CP040295.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1641400","datemodified":"2021-01-09T09:03:56","file_list":["cp041200.xml","cpqsetup.exe","cp_data.xml","icea65.cat","icea65.din","icea65.inf","icea65.sys","iceamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInICEa.dll"],"md5sum":"79a3932993f4a4a2e9945c265819acec","name":"cp041200.exe","release":"2021-01-09T08:49:04","revision":"0","sha1sum":"259d7879256c520fd1c1d488ed15ea9ec2d00a8e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec713af7b4"],"type_of_change":"0","version":"1.5.74.0"}],"id":{"product":"d1f7ec922ab94039a6f0bbcfd0b7a0b4","version":"3e7cdd2756c44f619daa342d0ce588ce"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"icea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19025379","datemodified":"2021-01-28T17:07:14","file_list":["/CP045848_BUILD_8.data","/CP045848.vmexe","/CP045848.vmexe64","/CP045848.vmfile","/CP045848_VMw.zip","/CP045848.xml","/payload.json","/CP045848_VMw.zip/index.xml","/CP045848_VMw.zip/vendor-index.xml","/CP045848_VMw.zip/metadata.zip","/CP045848_VMw.zip/vib20/CP045848/HPE_bootbank_CP045848_HPG4.8-7.0.0.15843807.vib","/CP045848_VMw.zip/metadata.zip/vendor-index.xml","/CP045848_VMw.zip/metadata.zip/vmware.xml","/CP045848_VMw.zip/metadata.zip/vibs/CP045848--8473193308270069714.xml","/CP045848_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045848_HPG4.8-7.0.0.15843807.xml"],"md5sum":"ab00bac8dc43bf29190bd30be1502102","name":"CP045848.zip","release":"2021-01-28T17:04:10","revision":"0","sha1sum":"8aa6b7501fe864ddbfc5ab50609c402291b24961","size":"18MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045848","version":"HPG4.8-7.0.0.15843807"}]}],"id":{"product":"fee6e5ef12074571bae786cf87c0e11d","version":"3e9b98374ba84e52bb20a46f6ce04ddc"},"installation":{"command":"CP043495.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU, VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T10:15:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.00"},{"DeviceName":"HPE D2220sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18e2e0d794","Version":"2.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;</strong>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4216013","datemodified":"2018-09-24T13:13:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/CP037680.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/She-200.fuf.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.00-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037680.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037680.scexe"],"md5sum":"35f6ce32c998f6becc66b700e67f519c","name":"firmware-smartarray-1d0696d939-2.00-2.1.x86_64.rpm","release":"2018-09-24T18:04:03","revision":"0","sha1sum":"97e540311b794158a9e14bd2e4e6d73c2325ee4d","size":"4MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef","b99dfb74-f0bc-464f-b418-cd18e2e0d794"],"type_of_change":"0","version":"2.00"}],"id":{"product":"4bd9dbd3dc9b4fbeb5492d2bb64a92e4","version":"4428fac338834945998a2ea0e0714e38"},"installation":{"command":"CP037680.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037680.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1d0696d939-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037680.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1d0696d939-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-24T17:59:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to support Service Pack for ProLiant version 2018.09.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2220sb","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"IEGen10_0.2.2.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.2.0"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"cn","x_late":"固件 - 系统 ROM"},{"lang":"ja","x_late":"ファームウェア - システム"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"16801146","datemodified":"2020-03-25T16:22:08","file_list":["IEGen10_0.2.2.0.signed.bin","IEGen10_0.2.2.0.xml","IEGen10_0.2.2.0B.signed.bin","payload.json"],"md5sum":"bab66aab090ca4d0e271c17551b042e8","name":"IEGen10_0.2.2.0.fwpkg","release":"2020-03-25T16:19:04","revision":"0","sha1sum":"4e801974b7ae047dbbcf2ffc4ea661b3fbc924d0","size":"16MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.2.0"}],"id":{"product":"91adee7c0766499184ce8d25a925669e","version":"e6a71d41719846a9b87799e1cfcc34fd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-04-25T10:49:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;0.2.1.2&nbsp;(B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 0.2.1.2.&nbsp; It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 0.2.1.2.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for HPE Persistent Memory featuring Intel Optane DC Persistent Memory.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<P><B>Important Notes:</B></P>None  <P><B>Firmware Dependencies:</B></P>None  <P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where Processor or Memory temperature reporting may not be collected properly by the platform and the system fans may be running faster than expected. This issue has been seen occasionally after a server reboot and is typically corrected with a subsequent server reboot. <P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:ie"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサー内のデバイスを識別するためのドライブなしのINFを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"551192","datemodified":"2020-12-03T03:06:22","file_list":["AMDCCP.cat","AMDCCP.inf","AmdIOV.cat","AmdIOV.inf","amdpcidev.cat","AMDPCIDev.inf","amdpsp.cat","amdpsp.inf","cp046033.xml","cpqsetup.exe","instnap3.dll","naplessp3.dll","SMBUSamd.cat","SMBUSamd.inf"],"md5sum":"650aa54cf3cbeb6b3f4cd9dc8720d4d6","name":"cp046033.exe","release":"2021-04-23T00:00:00","revision":"1","sha1sum":"5ce2396c4a326a8edd57ed52603f1a7070717f1d","size":"538KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca717eab0"],"type_of_change":"1","version":"3.1.0.0"}],"id":{"product":"500c2e8334cb4bd793078241d6489395","version":"f3b12cf262bc44309ae7f05932cc3cef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for AMD EPYC Processors for Microsoft Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-05-28T08:26:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Updated AMD IOMMU device</li>\n\t<li>Added support for HPE ProLiant Gen10 Plus Snap4 Latent servers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Updated AMD IOMMU device</li>\n\t<li>Added support for HPE ProLiant Gen10 Plus Snap4 Latent servers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"naplessp3.dll","sw_key_expectedpath":"%ProgramFiles%\\Chipset software"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.2.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1527576","datemodified":"2021-01-22T08:55:25","file_list":["cp044787.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"c315699d11fbe822e21c3fe59cb98fba","name":"cp044787.exe","release":"2021-01-22T08:52:17","revision":"0","sha1sum":"bbb2500168b458ece425afda1b06e222c5cd8500","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.2.20"}],"id":{"product":"ad60a281882240318ac9ec3091a5f1c9","version":"47b3212ba02042aeb598f269f63fe789"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.2.20</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"108000","datemodified":"2021-03-08T18:11:45","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"b3b57dda29e23e309de4df9c8806896a","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"8fb0af6de7ac770508fdb1950828ebb73bdc3848","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107845","datemodified":"2021-03-08T18:08:49","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"66ea757b46b623fa883d5d29e7effd81","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"ff330ccbf17369a2d139194fe48965df3364558c","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"b25d6b61a6364a739b769a23e6051253","version":"60f89ebb45d044a299c4062fd1930599"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045309.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.423"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3337360","datemodified":"2020-10-30T08:27:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/CP045311.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/cp045309.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/cp045309.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.423-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045311.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045311.scexe"],"md5sum":"6667ce9f8250dfc6870af34f98ca32b2","name":"firmware-spsgen10-04.01.04.423-1.1.x86_64.rpm","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"1e21b3ec7177ec1c7a09630b9db3c1abf26e4a73","size":"3MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"1","version":"04.01.04.423"}],"id":{"product":"84d998355c4f4bc6997437e9a6c61fba","version":"367b714ec28d4a94bd8dac6ae590697b"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">HP USB Key Utility</a></strong>を使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-11T03:52:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1229724","datemodified":"2021-01-09T00:03:34","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"904b263327d6629752ccc1aa0ffdbb76","name":"hp-ixgbevf-kmp-default-4.9.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-08T23:47:06","revision":"0","sha1sum":"15c5aa948fbdb4243bd87c018d547e0264ebf647","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1051756","datemodified":"2021-01-09T00:11:18","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"7a9b4c53e8af5825939776d0ca63e0e4","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-08T23:47:06","revision":"0","sha1sum":"c5c80884312d46c5c0c813fed605e6d58adf7ac0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"58259b45dec7469580dfbddb76171768","version":"c2e41e97e88146d4a8a621f0c2dbbfc5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel over Ethernet Driver kit for HPE Blade Emulex(BRCM) Mezzanine Converged Network Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1149134","datemodified":"2020-07-10T10:57:50","file_list":["/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip","/cp042231.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/brcmfcoe-12.0.1278.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/doc/README.txt","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/doc/release_note_brcmfcoe_12.0.1278.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/vendor-index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/vib20/brcmfcoe/EMU_bootbank_brcmfcoe_12.0.1278.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0.xml","/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-14896698.zip/VMW-ESX-6.5.0-brcmfcoe-12.0.1278.0-offline_bundle-14896698.zip/metadata.zip/vibs/brcmfcoe-5045933561286143092.xml"],"md5sum":"b006ac025aa6efb0e23e8914d0808398","name":"cp042231.zip","release":"2020-07-10T10:57:06","revision":"0","sha1sum":"4f88571d57874df7074d5f1c642b5561cd6d9e35","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2e31a109"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"brcmfcoe","version":"12.0.1278.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"65aa8ad51df14f7ca86c6de593b3ad6a","version":"05e467f5dc8642a8ae5bf9105544110b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex(BRCM) Mezzanine Fibre Channel over Ethernet driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:12:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1278.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"brcmfcoe:12.0.1278.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5487329","datemodified":"2020-12-13T14:01:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/CP045443.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/HAHC8SDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045443.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045443.scexe"],"md5sum":"fd3efb62320bd0709801719d94b47eee","name":"firmware-hdd-df22f7effd-HPDB-7.1.x86_64.rpm","release":"2020-12-13T13:49:04","revision":"0","sha1sum":"eac6cbed17e33b2123c138b2686d4689357cfa5c","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"9c74011372f646da931c0840d918013f","version":"862de50e8667442b9203e7abfa689a6b"},"installation":{"command":"CP040350.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JEQUV and MB8000JEQVA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33597630","datemodified":"2021-01-27T22:51:04","file_list":["payload.json","U45_2.42_01_23_2021.signed.flash","U45_2.42_01_23_2021.xml"],"md5sum":"d2eb9483182920fe42896a90779eeb5c","name":"U45_2.42_01_23_2021.fwpkg","release":"2021-01-27T22:47:05","revision":"0","sha1sum":"00847072c45a1a43a23eecac73de719a09a4a215","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"4bdcb7d3fc5c4d14af793003b89e365b","version":"1830e4909b824f42a783abe6d2617e6a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T22:18:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Added a new BIOS/Platform Configuration (RBSU) option to Advanced PCIe Device Configuration called PCIe Switch MMIO Configuration.  This option addresses a virtualization issue caused by different interpretations of the PCIe specification by disabling PCIE Switch MMIO Configuration.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"587947","datemodified":"2021-01-28T10:22:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"c04fee8fb9ba1e10d534a9a902005cb8","name":"elx-lpfc-kmp-default-12.8.352.11_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-28T10:18:05","revision":"0","sha1sum":"998fb2b498a53e0d6a2146e15beb7f648ef1b906","size":"574KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"cf36f8009ed4464f93a208bf9c35b47b","version":"511aa501d764457b94bb77a0ee75455d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 64-bit to enable the HPE Smart Array P824i-p MR controller. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array P824i-p MRコントローラーを有効にする、64-bit SUSE LINUX Enterprise Server 12用のビルド済みバイナリドライバーモジュールを提供します。 このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"612356","datemodified":"2018-12-12T09:00:46","file_list":["./lib/modules/4.4.73-5-default","./lib/modules/4.4.73-5-default/updates","./lib/modules/4.4.73-5-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"c9b715818cbada9c64c66b8595d1e39a","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles12sp3.x86_64.rpm","release":"2019-01-28T00:00:00","revision":"1","sha1sum":"eb25d5564be2900f4bdeb675ba66b922b2fe8840","size":"598KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"},{"bytes":"641346","datemodified":"2018-12-12T08:59:40","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"5cfab7a80d4dfc97f0817bfa7e305e41","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles12sp4.x86_64.rpm","release":"2019-01-28T00:00:00","revision":"1","sha1sum":"bacf3f85ebce9dde3fcdab654ec5eb58426d65ec","size":"626KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"b78250c893a84500a966768e0af25a67","version":"69d0331d632347d888b4d8a605efda59"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit SUSE LINUX Enterprise Server 12 "},{"lang":"ja","x_late":"64-bit SUSE LINUX Enterprise Server 12用HPE SmartアレイP824i-p MRコントローラードライバー "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-02T15:58:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>RC4 drop for snap4</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize and Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7 and 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29315888","datemodified":"2021-01-21T15:32:44","file_list":["/CP045036_BUILD_19.data","/CP045036.vmexe","/CP045036.vmexe64","/CP045036.vmfile","/CP045036_VMw.zip","/CP045036.xml","/payload.json","/CP045036_VMw.zip/index.xml","/CP045036_VMw.zip/vendor-index.xml","/CP045036_VMw.zip/metadata.zip","/CP045036_VMw.zip/vib20/CP045036/HPE_bootbank_CP045036_3.14.5.19-7.0.0.15843807.vib","/CP045036_VMw.zip/metadata.zip/vendor-index.xml","/CP045036_VMw.zip/metadata.zip/vmware.xml","/CP045036_VMw.zip/metadata.zip/vibs/CP045036-4298099504045307664.xml","/CP045036_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045036_3.14.5.19-7.0.0.15843807.xml"],"md5sum":"56794e29922c67e46ac092188b66074e","name":"CP045036.zip","release":"2021-01-21T15:30:05","revision":"0","sha1sum":"a376df1833ba2501d77579c8783affdcaaed9652","size":"27MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"0","version":"3.14.5","vib_list":[{"name":"CP045036","version":"3.14.5.19-7.0.0.15843807"}]}],"id":{"product":"79ba405b8c19425aa9a14902b672b652","version":"19fb43bb7c8642339768058f8e1b17de"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong><em>Additional Information:</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Intel 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Intel在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an WOL issue that system wakes up automatically if any magic packet being sent before system was shut down.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Systems Insight Display (SID) modul is green when there&#39;s no Network connection.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: XP0120GFJSL and XP0240GFJSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。XP0120GFJSLおよびXP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong><br />\n&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5421024","datemodified":"2020-12-13T15:55:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/ASAXHPS4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/CP045470.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045470.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045470.scexe"],"md5sum":"655e75492b32a473f551858e9a11c6ee","name":"firmware-hdd-d355375539-HPS4-9.1.x86_64.rpm","release":"2020-12-13T15:43:04","revision":"0","sha1sum":"8fa6d7498f9ac0633200535447eacc503d99c2d4","size":"5MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"426a1761f14e4ba492f138726a8bcbf6","version":"dc7e4db6722046549c01bf73d87fe552"},"installation":{"command":"CP040296.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - XP0120GFJSL and XP0240GFJSN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.7 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries."},{"lang":"ja","x_late":"HPE ESXiマネジメントSmartコンポーネントfor ESXi 6.7には、最新のHPE Common Information Model (CIM) Provider、HPE Integrated Lights-Out (iLO)ドライバー、HPE Compaq ROM Utility (CRU)ドライバー、HPE Agentless Management Service (AMS)、およびファイバーチャネル (FC) HBAアクセスライブラリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"32088548","datemodified":"2021-02-25T20:45:51","file_list":["/cp046907.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/index.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vendor-index.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/amshelpr-670.11.7.0.10-1.7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/fc-enablement-670.3.70.5-7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/amsd-670.11.7.1.2-1.7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/ilo_670.10.7.0.4-1OEM.670.0.0.7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/smx-provider-670.03.16.00.3-7535516.vib","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vendor-index.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vmware.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/amshelpr-3445758590712478404.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/fc-enablement--6828308359701880725.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/amsd-9205034306318449326.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/cru--1581854872647123919.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/ilo-5382991387560295609.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/vibs/smx-provider--6253706443730693861.xml","/esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.7uX-mgmt-bundle-3.7.1.2-1.zip/bulletins/esxi6.7uX-mgmt-bundle-3.7.1.2-1.xml"],"md5sum":"c295a0152ab2102ce306e0238155ae6a","name":"cp046907.zip","release":"2021-02-25T20:44:06","revision":"0","sha1sum":"210ef4db6f2eff301c02dcc9d263a6426b47777d","size":"30MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae","20a6e8e4-bf33-4c71-a6bf-d9eccb7b83b0","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec2fe8cc78"],"type_of_change":"1","version":"2021.04.12","vib_list":[{"name":"amshelpr","version":"670.11.7.0.10-1.7535516"},{"name":"fc-enablement","version":"670.3.70.5-7535516"},{"name":"amsd","version":"670.11.7.1.2-1.7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"},{"name":"ilo","version":"670.10.7.0.4-1OEM.670.0.0.7535516"},{"name":"smx-provider","version":"670.03.16.00.3-7535516"}]}],"id":{"product":"424586858da54235abb9a96e632bc309","version":"68e5bc824da645eca809f9b2c2fbe5d1"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"31000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-12T02:35:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix PSOD exception resulting from repeated failed attempts to communicate to iLO (Gen10 AMS only)</li>\n\t<li>Fix false NVMe disk temperature alerts</li>\n\t<li>Fix missing OS, driver and software info from AHS logs</li>\n\t<li>Fix max and threshold temperature values for SATA disks to prevent fans from running at higher rate</li>\n\t<li>Fix false SATA disk status change alerts<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Reduce Software Inventory cache refresh time&nbsp;to 15 seconds to help resolve OneView online SW update issues without reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"fc-enablement:670.3.70.5-7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amsd:670.11.7.1.2-1.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"smx-provider:670.03.16.00.3-7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:670.10.7.0.4-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amshelpr:670.11.7.0.10-1.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14021288","datemodified":"2021-01-21T15:14:28","file_list":["/CP045880_BUILD_6.data","/CP045880.vmexe","/CP045880.vmexe64","/CP045880.vmfile","/CP045880_VMw.zip","/CP045880.xml","/payload.json","/CP045880_VMw.zip/index.xml","/CP045880_VMw.zip/vendor-index.xml","/CP045880_VMw.zip/metadata.zip","/CP045880_VMw.zip/vib20/CP045880/HPE_bootbank_CP045880_1.20.6-7.0.0.15843807.vib","/CP045880_VMw.zip/metadata.zip/vendor-index.xml","/CP045880_VMw.zip/metadata.zip/vmware.xml","/CP045880_VMw.zip/metadata.zip/vibs/CP045880-8248971234257924202.xml","/CP045880_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045880_1.20.6-7.0.0.15843807.xml"],"md5sum":"227b1167a00758a799e1d22fcb0905ba","name":"CP045880.zip","release":"2021-01-21T14:59:05","revision":"0","sha1sum":"25e2b2b8a65faa4449a53ef58e410c9a402b1d9b","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.20","vib_list":[{"name":"CP045880","version":"1.20.6-7.0.0.15843807"}]}],"id":{"product":"cda15b2dd1914971b9e0993731ba714c","version":"6ca31391ed404b429968380c397a5207"},"installation":{"command":"CP045880.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HP Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM4 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-10T20:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11248068","datemodified":"2021-01-27T22:00:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/CP046682.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/U37_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046682.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046682.scexe"],"md5sum":"7982333c835d906ef0812c1448957d5a","name":"firmware-system-u37-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-27T21:52:05","revision":"0","sha1sum":"b468bb2fb0fbb7cd9a70d9b82d6c3e355facb8be","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"c02f997871554705a1c6e597965673df","version":"97628ae8f18543cdac2556582a15e687"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230k Gen10 (U37)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T19:56:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1313050","datemodified":"2021-01-27T03:41:56","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/0e","./usr/lib/.build-id/0e/c5dfaea20b9d7b15ac1b83a5215c819143f6a6","./usr/lib/.build-id/35","./usr/lib/.build-id/35/2c851b82729418cfc87feb9685b8da065cdbc9","./usr/lib/.build-id/48","./usr/lib/.build-id/48/6d732dedc335c482bb4af1a1138f9053aac11b","./usr/lib/.build-id/54","./usr/lib/.build-id/54/237dff4247c6655eb02eddd7a07232cf2ce316","./usr/lib/.build-id/57","./usr/lib/.build-id/57/682aa30b813771d23bbe1d882c30ade4bdee0f","./usr/lib/.build-id/81","./usr/lib/.build-id/81/68c0016bcf3afb1bd7700fa55076205f5b9aee","./usr/lib/.build-id/9b","./usr/lib/.build-id/9b/a54ca79ac50b56f4b960af1681669b30c0a9b0","./usr/lib/.build-id/a8","./usr/lib/.build-id/a8/af00758051f415638a2b73920f6d88adf6eeea","./usr/lib/.build-id/c7","./usr/lib/.build-id/c7/e51d0b735ff5505baaf4457f444fca4bb88d7f","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/ba44e9c4b4322de9a013a74d58a5306de00a79","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/libexec/rdma-set-sriov-vf","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/README.txt","./usr/share/doc/libvma/VMA_VERSION","./usr/share/doc/libvma/journal.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"343142a8d765ac4ef6065f85a65a9a43","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u3.x86_64.rpm","release":"2021-01-27T02:45:04","revision":"0","sha1sum":"1b1b7bb569a171889eebd2da040bb172a072fccf","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.2"},{"bytes":"1604464","datemodified":"2021-01-27T03:44:26","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"2bb2bdac11f2099f1c464bd915e08aea","name":"kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u3.x86_64.rpm","release":"2021-01-27T02:45:04","revision":"0","sha1sum":"26d9ce4155cfa6004a68d8050fce760641bebdb8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.2"}],"id":{"product":"3a09afbc8f48497998b1cf5fc8b9ef29","version":"8bec669252cf4c45a4159b91ff3a7948"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version &nbsp;4.18.0-240.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u3.x86_64.rpm mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 3 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives "},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、 LO2000KEFJU、LT0800KEXVA、LT1600KEXVBおよび LT2000KEXVC ドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"15706009","datemodified":"2020-06-15T21:03:48","file_list":["/CP044498_BUILD_1.data","/CP044498.vmexe","/CP044498.vmexe64","/CP044498.vmfile","/CP044498_VMw.zip","/CP044498.xml","/payload.json","/CP044498_VMw.zip/index.xml","/CP044498_VMw.zip/vendor-index.xml","/CP044498_VMw.zip/metadata.zip","/CP044498_VMw.zip/vib20/CP044498/HPE_bootbank_CP044498_HPK4.1-7.0.0.15843807.vib","/CP044498_VMw.zip/metadata.zip/vendor-index.xml","/CP044498_VMw.zip/metadata.zip/vmware.xml","/CP044498_VMw.zip/metadata.zip/vibs/CP044498--4211605597642422367.xml","/CP044498_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044498_HPK4.1-7.0.0.15843807.xml"],"md5sum":"afd7b1c02da89520a497a570e3ac6fb3","name":"CP044498.zip","release":"2020-06-15T21:01:04","revision":"0","sha1sum":"b0353d71958a84ae44010043b304854e4b9ab5ce","size":"14MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP044498","version":"HPK4.1-7.0.0.15843807"}]}],"id":{"product":"dea3d95c6cc64119ac507d9a05278db0","version":"6672f424804b44f39e3300014b3bf000"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-04T22:35:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11399868","datemodified":"2021-01-28T12:00:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/CP046643.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/U40_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046643.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046643.scexe"],"md5sum":"895068df0555379bdcbf8e3b06557419","name":"firmware-system-u40-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T11:53:05","revision":"0","sha1sum":"2bc63c202c48e4befcc197bd4fc7acbc758c423c","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"672edcd2af9a4bd18876e5e3192cd831","version":"fb8978ae477e402180f62b0246999986"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8761768","datemodified":"2021-03-15T22:31:01","file_list":["/CP047163.vmexe","/CP047163.vmexe64","/CP047163.vmfile","/CP047163.xml","/README.txt"],"md5sum":"6120dbc433f609f8a8bb8d16e9aefeaa","name":"CP047163.zip","release":"2021-03-16T03:28:05","revision":"0","sha1sum":"36fb1ec8a097b4c42d770661a0b838accbdf490d","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"ae3d527d10354a82bc7ece2ff1ca3e96","version":"80574330e1cc4b56b52d8e244c0bec1c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL380 Gen9/DL360 Gen9  (P89) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T03:21:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"3.53"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"3.53"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"3.53"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408e-m、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) -&nbsp;HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;3.53<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;3.21<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong>&nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;</p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名</strong><strong>：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows（x64）- HPE Smartアレイ408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-aおよびP416ie-m SR Gen10<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n     3.53<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     3.21<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     なし<br />\n<br />\n<strong>ファームウェアの依存関係:</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能</strong>：    </p>\n\n<ul>\n\t<li>UBMタイプ3バックプレーンのサポートを追加しました</li>\n\t<li>SATAドライブの長いデバイスモデル/製品IDのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong>     </p>\n\n<p>     </p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">定期的なI/Oの受信中にコントローラーが応答しなくなる可能性がある問題。</li>\n\t<li style=\"list-style-type: disc;\">エキスパンダーの構成中にファームウェアがデバイスを検出しようとし続けるため、ホストI/Oのタイムアウトが発生する可能性があります。</li>\n\t<li style=\"list-style-type: disc;\">サポートされていないブロックサイズの不良ドライブを使用すると、コントローラーのロックアップ問題（コード0x1E10）が発生することがあります。</li>\n\t<li style=\"list-style-type: disc;\">複数のホットプラグおよびホットリムーブイベント（ドライブまたはJBOD）が処理されているときに、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">コントローラーが、フラッシュバックライトキャッシュを有効にした論理ドライブを、論理ドライブの最後に向かってシーケンシャルリードでハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">I/Oが未処理の物理ドライブをホットプラグすると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストI/Oおよびバックグラウンド整合性チェックで、すべてのドライブに同じLBA上でUREが発生しているRAID-1 ADMストライプが同時に検出されると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストがコントローラー構成の消去コマンドまたはその他の構成変更コマンドを発行したときに、RAID6/60論理ドライブのドライブに障害が発生すると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">SSDデータドライブは、スペアの再構築が進行しているときにホットリムーブして再挿入すると、オフラインに設定される場合があります（理由コード0x37）。</li>\n\t<li style=\"list-style-type: disc;\">サニタイズ消去が終了した直後にシステムを再起動すると、ドライブがOSに公開されない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">12Gb SAS Expander Cardの特定のポート（ポート7以上）にUBMバックプレーンを接続すると、UBMバックプレーンが正しく検出されません。</li>\n\t<li style=\"list-style-type: disc;\">アイドル状態の後に短時間のI/Oを行うと、コントローラーがハングアップすることがあります。</li>\n\t<li style=\"list-style-type: disc;\">SATAドライブのドライブファームウェアのアップデート後に、コントローラーが以前のドライブファームウェアバージョンを返す場合があります。</li>\n\t<li style=\"list-style-type: disc;\">マルチエキスパンダーエンクロージャー構成でのエキスパンダーファームウェアのアップグレード中に、コントローラーがドライブを障害と見なす可能性があります（理由コード0x49、I/Oフリーズタイムアウトで）。</li>\n\t<li style=\"list-style-type: disc;\">特定のファンアウトエキスパンダータイプの外部エンクロージャーモデルで、ホットアドされたドライブのLED制御が失敗します。</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essentialシリーズコントローラーは、シーケンシャルI/Oを処理しているときに応答せず、ファームウェア合体ロジックがメモリを取得できない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">SmartCache構成でプライマリ論理ドライブへの断続的な書き込みI/Oエラーが発生すると、ファイルシステムまたはアプリケーションが古いデータを読み取る可能性があります。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし\n        </p>\n"}],"files":[{"bytes":"6320056","datemodified":"2021-02-16T12:35:55","file_list":["cp046357.xml","cpqsetup.exe","HPE_luxor.bin.fw","payload.json","setup.dll"],"md5sum":"04cf7473a63eea9fe8d4c4b1c810519d","name":"cp046357.exe","release":"2021-03-22T00:00:00","revision":"1","sha1sum":"492e204252a4b1e644d9b2ab4559f402186a81bf","size":"6MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"3.53"}],"id":{"product":"5ace706167bb418f8ac30077c43e3171","version":"b27a1e18ac83489096e937e70336ea25"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HPE Smart Update Managerを使用するには、</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>から以下の手順に従ってください:</strong></strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\packagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Smart Array P408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-aおよびP416ie-m SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-29T12:54:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while waiting for a non-existent pre-fetch queue entry.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with an unsupported block size is connected into slot 0.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue on DDR caching enabled logical volumes with sequential read towards the end of the volume.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue with outstanding I/Os on a degraded logical volume when the physical drive fails.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS after reboot if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in an expander card configuration.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when processing idle time followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11206846","datemodified":"2021-01-28T11:58:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/CP046646.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/U41_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046646.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046646.scexe"],"md5sum":"b18cc6f44feffff3bef79b6f3054e526","name":"firmware-system-u41-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-28T11:51:17","revision":"0","sha1sum":"e75456f87442726879e465a56dd7a51eb30136cd","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"d36b5614c00b4d00b66a58209cc5bffb","version":"b94a83cc8d4b4d3e826345e2d431aa74"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML350 Gen10 (U41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:17:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33598343","datemodified":"2021-01-28T10:08:17","file_list":["payload.json","U30_2.42_01_23_2021.signed.flash","U30_2.42_01_23_2021.xml"],"md5sum":"7ce8966d0b94e0bc8f50d322431fc866","name":"U30_2.42_01_23_2021.fwpkg","release":"2021-01-28T10:02:24","revision":"0","sha1sum":"da1326c88bebbcdbb0fc483050838c8f205573cb","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"ab0976902eae4e0c8757219b825c91f8","version":"0c0c89797243477fab615e13eccf9898"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL380 Gen10(U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:14:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1070320","datemodified":"2021-01-09T09:47:44","file_list":["cp045123.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"257a2d49aa5062bbc5a2b37d9eaa10a9","name":"cp045123.exe","release":"2021-01-09T09:31:28","revision":"0","sha1sum":"1b42d2f6baa7a9a6d62b924a3ae5939be04ab191","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"0","version":"12.18.11.1"}],"id":{"product":"5413adceb7d241de900274e399d9c777","version":"9b25db2e6857406f872ffca0eacc4876"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i350 Driver for Windows Server 2019"},{"lang":"ja","x_late":"Intel i350ドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"e1r68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported VMware ESXi Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるVMware ESXiオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HPE Smart Update Managerと一緒に使用することが出来ます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"15441852","datemodified":"2021-03-16T05:24:56","file_list":["/CP046983.vmexe","/CP046983.vmexe64","/CP046983.vmfile","/CP046983.xml","/README.txt"],"md5sum":"942b1a739d0a6c16c3b72cd95e5305c8","name":"CP046983.zip","release":"2021-03-16T10:22:05","revision":"0","sha1sum":"6f58bd365cc9f329e672695abe231db81edeb94b","size":"14MB","target_guids":[],"type_of_change":"2","version":"2.77","vib_list":[]}],"id":{"product":"866094c6d7794cccb749f7742eb5d7bc","version":"ea6daa23316b4319bcecdd250204e4dc"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HPE Smart Update Manager from the HPE Service Pack for ProLiant:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Note:&nbsp;The iLO 4 firmware update does not require a server reboot; however, if VMware ESXi is booting from an SD card, a reboot is required.</p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://h17007.www1.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">HPE Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created HPE Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>CD /hpe/swpackages and ./hpsum</li>\n\t<li>Select the next button</li>\n\t<li>Click Add Single Target</li>\n\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>Follow HPE Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip&nbsp;the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:\n\t<ul>\n\t\t<li>chmod +x CPXXXXXX.vmexe</li>\n\t</ul>\n\t</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Upgrade Requirement:&nbsp;Lowering the severity of the upgrade requirement to Recommended as per the HPE Product Security Policy. It is based on the CVE score for this security vulnerability (7.3), assessment of the impact and the probability of occurrence. So upgrade requirement has been revised to &lsquo;Recommended&rsquo; upgrade.</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください。</strong><br />\n     注記: iLO 4ファームウェアのアップデートではサーバーのリブートが不要です。ただし、VMware ESXiをSDカードから起動する場合は、リブートが必要です。</p>\n\n<p><strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>を使用して<a href=\"http://h17007.www1.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">HPE Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したHPE Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>リモートオンライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li>CD /hpe/swpackagesおよび./hpsum</li>\n\t<li>次へボタンを選択します。</li>\n\t<li>シングルターゲットの追加をクリックします。</li>\n\t<li>アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n</ul>\n\n<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:\n\t<ul>\n\t\t<li>chmod +x CPXXXXXX.vmexe</li>\n\t</ul>\n\t</li>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p> </p>\n\n<p>アップグレード要件：HPE製品セキュリティポリシーに従って、アップグレード要件の深刻度を推奨に下げます。これは、このセキュリティの脆弱性のCVEスコア（7.3）、影響の評価、および発生の可能性に基づいています。そのため、アップグレード要件が‘推奨’アップグレードに改訂されました。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi  - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi -HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-02T07:08:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to display login banner SSH login</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Potential vulnerabilities in network stack. Click <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=hpesbhf04070en_us\">here</a> to know more about the Security Vulnerabilities.</li>\n\t<li>Active directory test may fail during LDAP authentication.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fail to deploy iLO Firmware from SPP on Gen9 servers running ESXi&nbsp;7.x with an error &quot;Update Returned an Error&quot;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1525441","datemodified":"2021-01-27T05:06:12","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"4094a67d11ea8baca7ed7c13e3afeb0b","name":"mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_94.41-OFED.5.2.1.0.4.1.sles12sp4.x86_64.rpm","release":"2021-01-27T03:51:05","revision":"0","sha1sum":"edf64b9ac5fee9723dadd3d62945934c2186c3f4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1227938","datemodified":"2021-01-27T05:01:10","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/rdma-set-sriov-vf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.2.2","./usr/share/doc/packages/libvma-9.2.2/README.txt","./usr/share/doc/packages/libvma-9.2.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.2.2/journal.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"112736fa8b5818a3952336305599a02a","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles12sp4.x86_64.rpm","release":"2021-01-27T03:51:05","revision":"0","sha1sum":"da26fe9013fbd026c811465aa98c2b5fda7c89f3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"1f96d5ce1b7c4e7fae4a08d7d5e4898d","version":"51dd40934f09487a97f623102c08ad76"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles12sp4.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.2_k4.12.14_94.41-OFED.5.2.1.0.4.1.sles12sp4.x86_64.rpm</strong><br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HP 6Gb SAS BL Switch.  After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HP 6Gb SAS BLスイッチのファームウェア イメージが含まれています。  コンポーネントをダウンロードしてディレクトリにファームウェア イメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.2.0<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (B):</strong><strong>&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:40px\">None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n"}],"files":[{"bytes":"34000365","datemodified":"2018-09-26T20:07:41","file_list":["./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.cpq_package.inc","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/CP037681.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/cp_data.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/hpsetup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/vsm_release_4.3.6.0.img","./usr/lib/i586-linux-gnu/hp-scexe-compat","./usr/lib/i586-linux-gnu/hp-scexe-compat/CP037681.scexe","./usr/lib/i586-linux-gnu/scexe-compat","./usr/lib/i586-linux-gnu/scexe-compat/CP037681.scexe"],"md5sum":"301d93fa1148fd24956bbc22a2fe057c","name":"firmware-solex6gb-solex-4.3.6.0-2.1.i586.rpm","release":"2018-09-27T01:00:04","revision":"0","sha1sum":"be24adb881bd827d01e426b4302589725d1bdd4a","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"a2a4da3071f14ea0b229b51686cf6bd9","version":"0ed32969accd4e30809f5ca59302841a"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><br />\n<strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;This extracts the contents of the rpm to the &#39;/usr/lib/<strong>x86_64-linux-gnu</strong>&#39; location</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system.&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the&nbsp;</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a><strong>(SPP) and follow these steps:</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>..</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO.</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><br />\n<strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/<strong>x86_64-linux-gnu</strong>' の場所へrpm の内容を解凍します。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート</em></strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。 </p>\n\n<p> </p>\n\n<p><strong><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a><strong>（SPP）を入手して、以下の手順を実行することをおすすめします。</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)"},{"lang":"ja","x_late":"オンラインHP 6Gb SAS BLスイッチファームウェア Smart Component for Linux (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-24T18:13:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial drop for Snap3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP5 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP5 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23059","datemodified":"2021-02-11T00:40:04","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"0e915653a80d4ceda0f5ff877e461ef5","name":"libbnxt_re-218.0.7.0-sles12sp5.x86_64.rpm","release":"2021-02-11T00:32:08","revision":"0","sha1sum":"d80ceba1a8b3e22bee061069bfe134b61ebbc94a","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"a9179e239bb643d4b08c6272f4499a35","version":"d575131e632a4d9c8ae1bc9646cebfbe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP5"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP5用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22652","datemodified":"2021-02-11T00:37:49","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"df5b9fcd1303f253ae6b45ba4439172c","name":"libbnxt_re-218.0.7.0-sles15sp2.x86_64.rpm","release":"2021-02-11T00:33:08","revision":"0","sha1sum":"012efcbae595aad4bb61490823111fb020fcb8a6","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"ae3d91fc556c4e44b780b594f473e350","version":"1a1a8d6697e04bd09b91ba9e90cd9022"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP2"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6392859","datemodified":"2021-03-08T18:39:23","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"9e2d64a72940eda8bb4849c8988edc78","name":"netxtreme2_bl-kmp-default-7.14.76_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:21:04","revision":"0","sha1sum":"a06f9bea8c6f23ee572f8e11cf9fc05f0d35690e","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"6277086","datemodified":"2021-03-08T18:37:59","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/bnx2.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2fc.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2i.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2x.ko","./lib/modules/4.12.14-94.41-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"e79b75a9bc8c06a0a04b24d9609d01f3","name":"netxtreme2_bl-kmp-default-7.14.76_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:21:04","revision":"0","sha1sum":"f25ee94a4327a485cb4e512f26b6b1b160545d84","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"6f63395ea958425f83bb31303381afd1","version":"c4e04a1114654229848238d8de9d91ee"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers correct an issue where iSCSI target discovery fails to complete when booting from SAN or a local HD.</p>\n\n<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"14862215","datemodified":"2021-01-08T13:40:05","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"f9f33e864b16f92cd1d895fd1e4907a6","name":"qlgc-fastlinq-kmp-default-8.55.5.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-08T13:13:05","revision":"0","sha1sum":"9a4b71e1fb8e3fbaccd012c25f5907ad198a204a","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.5.0-1"},{"bytes":"13840487","datemodified":"2021-01-08T13:46:39","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.17.0.bin","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/4.12.14-195-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"b3bbf3b2dafa1ee0d65a5618c45fa14e","name":"qlgc-fastlinq-kmp-default-8.55.5.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-08T13:13:05","revision":"0","sha1sum":"936196065a2cfa4ee7ed66e7c0ddcef9b87b56d4","size":"13MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"0","version":"8.55.5.0-1"}],"id":{"product":"39b3bcd8f8b243ad9879002d6ba846cc","version":"4c83e68432c04363b6dace30a1575749"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 15 SP2.</li>\n\t<li>This product now adds PCIe Advanced Error Recovery (AER) support.</li>\n\t<li>This product now supports RoCE bonding mode.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which system crash after unloading and reloading only roce driver</li>\n\t<li>This product corrects an issue which VF RDMA system crash in overnight reboot test on multiple VMs</li>\n\t<li>This product corrects an issue which VMs crash randomly upon advanced property disable/enable with Max VFs enumerated on all PFs</li>\n\t<li>This product corrects an issue which iSCSI BFS system fails to reboot if one port is down and reboot is attempted</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><br />\nThis product now supports Suse Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.</li>\n\t<li>This product corrects an issue ethernet data rate limiting unable on VFs.</li>\n\t<li>This product addresses a system crash seen when injecting a fw_assert on a NIC PF.</li>\n\t<li>This product addresses a system crash seen when limiting number of MSI-X interrupt vectors as requested for VFs</li>\n\t<li>This product addresses a system crash seen when unloading and reloading the RoCE driver only.</li>\n\t<li>This product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.</li>\n\t<li>This product addresses a the connection recover failed with heavy traffic</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEFNAおよびMB6000GEFNBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5294982","datemodified":"2020-12-13T13:30:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/CP045433.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/SMKRATG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045433.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045433.scexe"],"md5sum":"40fa93a308cffb337050f1f7e4acb28a","name":"firmware-hdd-40277d55d3-HPG6-9.1.x86_64.rpm","release":"2020-12-13T13:17:05","revision":"0","sha1sum":"c34cca45f62faf5e8ecec5aee626b4aa2d86e50a","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"72599cd140dd4be0b9dbc3875c332654","version":"4cb761579d3a48d7ac8e4ca388614a80"},"installation":{"command":"CP040261.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEFNA and MB6000GEFNB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5474563","datemodified":"2020-11-26T07:21:32","file_list":["/CP044764_BUILD_13.data","/CP044764.vmexe","/CP044764.vmexe64","/CP044764.vmfile","/CP044764_VMw.zip","/CP044764.xml","/payload.json","/CP044764_VMw.zip/index.xml","/CP044764_VMw.zip/vendor-index.xml","/CP044764_VMw.zip/metadata.zip","/CP044764_VMw.zip/vib20/CP044764/HPE_bootbank_CP044764_2021.02.01.13-7.0.0.15843807.vib","/CP044764_VMw.zip/metadata.zip/vendor-index.xml","/CP044764_VMw.zip/metadata.zip/vmware.xml","/CP044764_VMw.zip/metadata.zip/vibs/CP044764--8441422127484966260.xml","/CP044764_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044764_2021.02.01.13-7.0.0.15843807.xml"],"md5sum":"eda8a90ea53d51ae9439830dc2bc4548","name":"CP044764.zip","release":"2020-11-26T07:17:05","revision":"0","sha1sum":"135131f31db513740c6b23550e2f87cf5b573f93","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044764","version":"2021.02.01.13-7.0.0.15843807"}]}],"id":{"product":"085dc91909144ecd8918a217072a43fb","version":"10d4765adfcb47ceab4cd994cbfdba3b"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>12.60a4</td>\n\t\t\t<td>2.10X6</td>\n\t\t\t<td>12.6.284.0</td>\n\t\t\t<td>12.6.302.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.7</td>\n\t\t\t<td>12.6.271.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP, and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) -  VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2907840","datemodified":"2020-12-16T07:19:51","file_list":["cp045575.xml","cpqsetup.exe","GPM853G1.rel","payload.json","setup.dll"],"md5sum":"f5365daafe2b43515afe4514383354c3","name":"cp045575.exe","release":"2020-12-16T07:11:05","revision":"0","sha1sum":"16bfab2c51198963ec347a9928686cf32f143d8d","size":"2MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"6f3decdb759d4bafa6df9af42f08e497","version":"1b3747deffb24a5eb716443fe8745b98"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:00:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3581424","datemodified":"2020-12-16T19:50:04","file_list":["cp045538.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNSD3.rel"],"md5sum":"a214215765aca8fb3747da5d06fe7448","name":"cp045538.exe","release":"2020-12-16T19:31:14","revision":"0","sha1sum":"c87b26346e61eb525f8aa19e028fd3886936e3f6","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"85555c0bf7a54baebd117b6f0dbd865a","version":"561e12c2d63948df9ea20a9854feac64"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:45:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS35, provides Windows 64-bit support for HPE MR416i-p MR416i-a MR216i-p MR216i-a controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"891632","datemodified":"2021-02-01T15:08:00","file_list":["cp044907.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"md5sum":"6c16bb1956092c00e59ff7cdcecfe3cc","name":"cp044907.exe","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"78fcfa76618b9f3347fe7d1c67dada72b3d49af1","size":"870KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.716.3.0"}],"id":{"product":"4c4e15e3e8d243efae5ab2580b253cde","version":"8f2a5907322c4d90a294eef9cedc909a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"},{"lang":"ja","x_late":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p MR416i-a MR216i-p MR216i-a  64-bit controller driver for Microsoft Windows 2019 edition."}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T13:05:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"MegaSas35.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14022044","datemodified":"2021-01-23T07:52:51","file_list":["/CP045879_BUILD_9.data","/CP045879.vmexe","/CP045879.vmexe64","/CP045879.vmfile","/CP045879_VMw.zip","/CP045879.xml","/payload.json","/CP045879_VMw.zip/index.xml","/CP045879_VMw.zip/vendor-index.xml","/CP045879_VMw.zip/metadata.zip","/CP045879_VMw.zip/vib20/CP045879/HPE_bootbank_CP045879_1.20.9-7.0.0.15843807.vib","/CP045879_VMw.zip/metadata.zip/vendor-index.xml","/CP045879_VMw.zip/metadata.zip/vmware.xml","/CP045879_VMw.zip/metadata.zip/vibs/CP045879-451616993367834935.xml","/CP045879_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045879_1.20.9-7.0.0.15843807.xml"],"md5sum":"a81d718743706e555ff03fca151e0966","name":"CP045879.zip","release":"2021-01-23T07:40:04","revision":"0","sha1sum":"f09690c32aa086b5e5b36486ff21f45e1fa2b6a4","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.20","vib_list":[{"name":"CP045879","version":"1.20.9-7.0.0.15843807"}]}],"id":{"product":"0720b596fe34472ebce943ceb259ae5a","version":"4a872bdd6e2a4f0cace215643309cf8c"},"installation":{"command":"CP045879.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HP Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM3 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-10T20:10:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"316463","datemodified":"2021-01-14T07:13:59","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnxt_en.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"6fab2c585f1b17f3f7b917e35967cab6","name":"bnxt_en-kmp-default-1.10.2_k5.3.18_22-218.0.67.0.sles15sp2.x86_64.rpm","release":"2021-01-14T06:45:05","revision":"0","sha1sum":"b3347c82ac0e5bf5682803c25690f069aebdd3e5","size":"309KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"304978","datemodified":"2021-01-14T07:05:34","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/bnxt_en.ko","./lib/modules/4.12.14-195-default/updates/drivers","./lib/modules/4.12.14-195-default/updates/drivers/infiniband","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-195-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"be75b5ac2eb357caee75e85a57eb79d9","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_195-218.0.67.0.sles15sp1.x86_64.rpm","release":"2021-01-14T06:45:05","revision":"0","sha1sum":"7e976c0db5e67cf82efed1393a2c1c7cc1f2ce4d","size":"297KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"2ed4fb56e81f45b0b8ae601a61b78e6c","version":"f4dc0a0dbb32404c84435b00ce283016"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted.</li>\n\t<li>This product corrects an issue which HPSUM selects driver for SUSE Linux Enterprise Server 15 while SPP deployment running with SUSE Linux Enterprise Server 15 Service Pack 1 platform.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5908384","datemodified":"2020-10-30T06:41:39","file_list":["SignedImageInstaller64.dll","U19_2.80_10_16_2020.signed.flash","cp046201.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"d88e3805f78d615b71588851259ba42b","name":"cp046201.exe","release":"2020-10-30T06:24:07","revision":"0","sha1sum":"877f4ce2db9205fb7abefb7679964d3bc29a4eb7","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"9f645709728442bbae04d049c43912b7","version":"f2b5c50aa2a34f64aa239eb5e3553078"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-30T06:21:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5975288","datemodified":"2020-11-04T03:46:02","file_list":["P89_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046145.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"cce4897311262c8ec8385216f455bb9f","name":"cp046145.exe","release":"2020-11-04T03:27:13","revision":"0","sha1sum":"103ae9b90790e7b8e501b6e8346cb334f7130fed","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"d9e09b131d654a8aa7aba135504d8639","version":"e8e9ae0a703a43029c95c39b551ea81f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":" Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers"},{"lang":"ja","x_late":" オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T07:00:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD3"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントはドライブモデル：EG000600JWFUVおよびEG001200JWFVA のファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWFUV and&nbsp;EG001200JWFVA&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4738848","datemodified":"2020-12-13T08:08:46","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/CP045378.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/T14SELD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045378.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045378.scexe"],"md5sum":"2e9fd400365afddae8806cae97e0cfa1","name":"firmware-hdd-f0c91d2fe3-HPD3-6.1.x86_64.rpm","release":"2020-12-13T07:56:07","revision":"0","sha1sum":"2ab04deca1d79ff9c717e435479f20a7d449c017","size":"4MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"0","version":"HPD3"}],"id":{"product":"0d53f18d93f34c14a12850b4c4f5646a","version":"f0244aa08bb34cd5927e02cb83731038"},"installation":{"command":"CP040324.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWFUV and EG001200JWFVA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:30:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD5"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR and EG002400JWJNT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18587479","datemodified":"2021-01-27T12:22:10","file_list":["/CP045609_BUILD_4.data","/CP045609.vmexe","/CP045609.vmexe64","/CP045609.vmfile","/CP045609_VMw.zip","/CP045609.xml","/payload.json","/CP045609_VMw.zip/index.xml","/CP045609_VMw.zip/vendor-index.xml","/CP045609_VMw.zip/metadata.zip","/CP045609_VMw.zip/vib20/CP045609/HPE_bootbank_CP045609_HPD5.4-7.0.0.15843807.vib","/CP045609_VMw.zip/metadata.zip/vendor-index.xml","/CP045609_VMw.zip/metadata.zip/vmware.xml","/CP045609_VMw.zip/metadata.zip/vibs/CP045609-7238939843760040729.xml","/CP045609_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045609_HPD5.4-7.0.0.15843807.xml"],"md5sum":"6c2c7d1a76c4ab991efd6a5de8de5d7f","name":"CP045609.zip","release":"2021-01-27T12:19:04","revision":"0","sha1sum":"8305cd4875b3f56f09c717cc2f993756363f54b0","size":"17MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP045609","version":"HPD5.4-7.0.0.15843807"}]}],"id":{"product":"58058fc7c39a49caa2844dbe139ab3f9","version":"4dc4035f627f4344abfa6c7924044fbc"},"installation":{"command":"CP042785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:14:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55719","datemodified":"2021-03-08T18:21:39","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"55d0cb98b1063986e18fdb8e1d322a53","name":"kmod-hp-ixgbevf_bl-4.9.3-2.rhel8u3.x86_64.rpm","release":"2021-03-08T18:13:08","revision":"0","sha1sum":"5b123fef314fcb293a1e72e94ee276878015d417","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"55576","datemodified":"2021-03-08T18:18:53","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"662f72d6a9be43e2ae8b193919c156d4","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel8u2.x86_64.rpm","release":"2021-03-08T18:13:08","revision":"0","sha1sum":"5d95bbf93aafb6dedb374f896b49cb0ae35450e6","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"1645a3fa489f4a55a83d6b3479318292","version":"97d34d3cb6e74f8e8e4ee4ac61bcf14a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"26854743","datemodified":"2021-02-03T04:16:05","file_list":["/CP044870.vmexe","/CP044870.vmfile","/CP044870_VMw.zip","/CP044870.xml","/payload.json","/CP044870_VMw.zip/index.xml","/CP044870_VMw.zip/vendor-index.xml","/CP044870_VMw.zip/metadata.zip","/CP044870_VMw.zip/vib20/CP044870/HPE_bootbank_CP044870_1.0.1-6.7.0.7535516.vib","/CP044870_VMw.zip/metadata.zip/vendor-index.xml","/CP044870_VMw.zip/metadata.zip/vmware.xml","/CP044870_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044870_1.0.1-6.7.0.7535516.xml","/CP044870_VMw.zip/metadata.zip/vibs/CP044870-498833910419803177.xml"],"md5sum":"8c9e49a5d435f13598645cb1a278da37","name":"CP044870.zip","release":"2021-02-03T04:21:05","revision":"0","sha1sum":"aa0d96b01e3a5220849b909991b9c2268c6d7c67","size":"25MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP044870","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"f1f8da98d16b4dea87d58e2bbca62959","version":"97e24666c65744f38ea294829dcb2217"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T11:59:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.27.6008:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when&nbsp;connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>ConnectX-6: 20.27.2008*<br />\n\t\t*Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link&nbsp;speeds.</li>\n\t</ul>\n\t</li>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>Enabled KP4RS FEC on Active Fiber cable up to 30m.</li>\n\t\t<li>FDR protocol.</li>\n\t\t<li>Enabled updating End-to-End (E2E) credit packets instantly.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>There are no new fixes in firmware version 20.27.6008.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.29.1016:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:<br />\n&nbsp; &nbsp;</strong>&nbsp; Added support for Windows 2019.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3099992","datemodified":"2021-01-28T23:59:55","file_list":["4ICDHPK1.rel","cp046729.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"0b07bb1af287af7161c6d774495efa3a","name":"cp046729.exe","release":"2021-01-28T23:44:04","revision":"0","sha1sum":"8a72bfe7fa03d87521fada229b06db97e08e1186","size":"2MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"73c467f62ccd4e6c837bbb93fd6013e1","version":"5ef23b1092454b9882f6774145a3d341"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-28T17:29:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.40 (02/24/2021)"},{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.40_02_24_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022e","Version":"v2.40 (02/24/2021)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33739850","datemodified":"2021-02-25T16:00:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/A48_2.40_02_24_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/CP046363.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.40_2021_02_24-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046363.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046363.scexe"],"md5sum":"93339855ff741599e8d02a19cb42d6e8","name":"firmware-system-a48-2.40_2021_02_24-1.1.x86_64.rpm","release":"2021-02-25T15:52:05","revision":"0","sha1sum":"bc90c0ec89ffce7c4d3826d0437668fa568261e2","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f","00000000-0000-0000-0000-00000000022e"],"type_of_change":"0","version":"2.40_02-24-2021"}],"id":{"product":"1e4f77062f4d48c8906f4212d8016a76","version":"6776922b80e843cb95c774a1f03796c9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-30T19:48:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17395501","datemodified":"2021-01-27T12:59:04","file_list":["/CP045611_BUILD_3.data","/CP045611.vmexe","/CP045611.vmexe64","/CP045611.vmfile","/CP045611_VMw.zip","/CP045611.xml","/payload.json","/CP045611_VMw.zip/index.xml","/CP045611_VMw.zip/vendor-index.xml","/CP045611_VMw.zip/metadata.zip","/CP045611_VMw.zip/vib20/CP045611/HPE_bootbank_CP045611_HPD6.3-7.0.0.15843807.vib","/CP045611_VMw.zip/metadata.zip/vendor-index.xml","/CP045611_VMw.zip/metadata.zip/vmware.xml","/CP045611_VMw.zip/metadata.zip/vibs/CP045611--5571914708254799982.xml","/CP045611_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045611_HPD6.3-7.0.0.15843807.xml"],"md5sum":"bdf4a5dd5557aba0e76cc2111d33dbce","name":"CP045611.zip","release":"2021-01-27T12:56:04","revision":"0","sha1sum":"e58d38b590fdc3dd2ceb5534773755c06bf2e93d","size":"16MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP045611","version":"HPD6.3-7.0.0.15843807"}]}],"id":{"product":"f47f99ce0a3d4f73a3af884b56c63c54","version":"6504a78770e4442db9a48c665739b35f"},"installation":{"command":"CP042546.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:16:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17164151","datemodified":"2021-01-27T19:38:50","file_list":["/CP045622_BUILD_4.data","/CP045622.vmexe","/CP045622.vmexe64","/CP045622.vmfile","/CP045622_VMw.zip","/CP045622.xml","/payload.json","/CP045622_VMw.zip/index.xml","/CP045622_VMw.zip/vendor-index.xml","/CP045622_VMw.zip/metadata.zip","/CP045622_VMw.zip/vib20/CP045622/HPE_bootbank_CP045622_HPD4.4-7.0.0.15843807.vib","/CP045622_VMw.zip/metadata.zip/vendor-index.xml","/CP045622_VMw.zip/metadata.zip/vmware.xml","/CP045622_VMw.zip/metadata.zip/vibs/CP045622--1275220548384588469.xml","/CP045622_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045622_HPD4.4-7.0.0.15843807.xml"],"md5sum":"4a756404cbffb9bc7b38c968d71f76ea","name":"CP045622.zip","release":"2021-01-27T19:36:09","revision":"0","sha1sum":"27a046aa9362a11bcbc21e6ad911dc089ce69873","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045622","version":"HPD4.4-7.0.0.15843807"}]}],"id":{"product":"10fb5093c8b24e83a8541c8c40bc7e15","version":"07f22d5bbb7e4f68aca19c3d138c3fa8"},"installation":{"command":"CP039423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:25:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16173206","datemodified":"2021-01-27T11:17:55","file_list":["/CP046334_BUILD_2.data","/CP046334.vmexe","/CP046334.vmexe64","/CP046334.vmfile","/CP046334_VMw.zip","/CP046334.xml","/payload.json","/CP046334_VMw.zip/index.xml","/CP046334_VMw.zip/vendor-index.xml","/CP046334_VMw.zip/metadata.zip","/CP046334_VMw.zip/vib20/CP046334/HPE_bootbank_CP046334_HPG7.2-7.0.0.15843807.vib","/CP046334_VMw.zip/metadata.zip/vendor-index.xml","/CP046334_VMw.zip/metadata.zip/vmware.xml","/CP046334_VMw.zip/metadata.zip/vibs/CP046334--6964824698655647654.xml","/CP046334_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046334_HPG7.2-7.0.0.15843807.xml"],"md5sum":"b202c6a5d8f48b70e73a7dedf139a7e6","name":"CP046334.zip","release":"2021-01-27T11:14:04","revision":"0","sha1sum":"01a9de135fd6d983395aeecba2d8a24bcd02f8ee","size":"15MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7","vib_list":[{"name":"CP046334","version":"HPG7.2-7.0.0.15843807"}]}],"id":{"product":"e6ce1a91bd5b4f829c98f53210189206","version":"6ad4ca3a64254073bbe3f33279030352"},"installation":{"command":"CP042459.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-24T09:47:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware revision improves low-temperature performance and Error Correction Code (ECC) error recording for some commands.&nbsp;</li>\n\t<li>It also improves internal logging capabilities for failure analysis.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800095","languages":[{"lang":"fr","x_late":"Logiciel - Réseau"},{"lang":"en","x_late":"Software - Network"},{"lang":"cn","x_late":"软件 - 网络"},{"lang":"tw","x_late":"軟體 ─ 網路"},{"lang":"de","x_late":"Software - Netzwerk"},{"lang":"ko","x_late":"소프트웨어 - 네트워크"},{"lang":"it","x_late":"Software - Rete"},{"lang":"ja","x_late":"ソフトウェア - ネットワーク"},{"lang":"es","x_late":"Software - Red"}]}],"description":[{"lang":"tw","x_late":"此代理程式會從執行 Linux x86_64 平台的 HPE ProLiant 伺服器內受支援的 Intel 網路配接卡擷取感測器與健康狀況資料。"},{"lang":"en","x_late":"This agent extracts sensor and health data from supported Intel network adapters in HPE ProLiant servers running Linux x86_64 platforms."},{"lang":"ko","x_late":"이 에이전트는 Linux x86_64 플랫폼을 실행하는 HPE ProLiant 서버에서 지원되는 Intel 네트워크 어댑터로부터 센서 및 상태 데이터를 추출합니다."},{"lang":"cn","x_late":"该代理可在运行 Linux x86_64 平台的 HPE ProLiant 服务器中从支持的英特尔网络适配器解压传感器和状态数据。"},{"lang":"ja","x_late":"このエージェントは、Linux x86_64プラットフォームを実行しているHPE ProLiantサーバーでサポートされているIntelネットワークアダプターから、センサーおよびヘルスのデータを抽出します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"57711","datemodified":"2019-11-06T08:59:31","file_list":["./etc/init.d/ocsbbd","./usr/lib/ocsbbd/ocsbbd.rhel","./usr/lib/ocsbbd/ocsbbd.sles","./usr/sbin/ocsbbd","./usr/share/man/man8/ocsbbd.8.gz","./usr/share/smartupdate/hp-ocsbbd/component.xml"],"md5sum":"a67b0a829f7cb1c475953576533e8487","name":"hp-ocsbbd-1.1.85.0-1.x86_64.rpm","release":"2020-03-09T00:00:00","revision":"1","sha1sum":"1658b99d19c1905190cf8dfa4cf02d78440c0b3a","size":"56KB","target_guids":[],"type_of_change":"0","version":"1.1.85.0-1"}],"id":{"product":"3129a8bb92a043939b7bf306836723ed","version":"58e5417a5fbc4932b7450bf655ca2fbb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download hp-ocsbbd-1.1.85.0-1.x86_64.txt to view installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順を確認するには、hp-ocsbbd-1.1.85.0-1.x86_64.txtをダウンロードしてください。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 HPE ProLiant 網路配接卡的 Intel Active Health System 代理程式 (適用於 Linux x86_64)"},{"lang":"en","x_late":"Intel Active Health System Agent for HPE ProLiant Network Adapters for Linux x86_64"},{"lang":"ko","x_late":"HPE 프로라이언트 네트워크 어댑터용 Intel Active Health System Agent(Linux x86_64)"},{"lang":"cn","x_late":"适用于采用 Linux x86_64 的 HPE ProLiant 网络适配器的 Intel Active Health System 代理"},{"lang":"ja","x_late":"HPE ProLiantネットワークアダプター for Linux x86_64用Intel Active Health Systemエージェント"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1521","subdev":"2226","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1523","subdev":"339F","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-03T14:01:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n","latest_fixes_x_late":"<p>This product fixes an issue that it takes long time to boot-up server due to ocsbbd service.</p>\n"},{"curr_enhancements_x_late":"<p>SUM no longer attempts to install this product on Gen10 servers, which this product&nbsp;does not support.</p>\n","curr_fixes_x_late":"<p>This product fixes an issue that it takes long time to boot-up server due to ocsbbd service.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hp-ocsbbd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Windowsオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20235536","datemodified":"2021-01-19T07:55:57","file_list":["cp045195.xml","cpqsetup.exe","fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"c791ff0b182b9c1a7938ac4864249295","name":"cp045195.exe","release":"2021-01-19T07:53:06","revision":"0","sha1sum":"887a300e3943fbc55e9e1ff4cce0ce1c66cd5157","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.0.14"}],"id":{"product":"00184010ed0a41829836f7c60269273f","version":"57f83b71a4454c1eb93347426adf1000"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n インストールボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Windows x64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.28.1016:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5947728","datemodified":"2020-11-04T10:44:56","file_list":["SignedImageInstaller64.dll","U15_2.80_10_16_2020.signed.flash","cp046165.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"5cf21f81f8c540ad99d43b9f8358404d","name":"cp046165.exe","release":"2020-11-04T10:28:05","revision":"0","sha1sum":"f7eed61f24035cdb4d702072629a485513d65792","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"56e73eced8704b9c871e50e0afbcdc84","version":"fe788d7f24234926b2330543b27d3985"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T06:46:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5953323","datemodified":"2020-12-13T12:46:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/CP045417.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/HVLPeAsseFD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045417.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045417.scexe"],"md5sum":"1ed52b13f1b6db7950c367ef3e24e282","name":"firmware-hdd-8b26d1ef02-HPD1-4.1.x86_64.rpm","release":"2020-12-13T12:33:04","revision":"0","sha1sum":"8162c52f1d6a3e251c2853735dfc89b72ae51c00","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"596340d3247946aaa109faeb065a7eab","version":"65ec087b7cd14d1680d8397416f24010"},"installation":{"command":"CP041479.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653106A-HDAT PCIe4 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter(P31324-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000594</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5524541","datemodified":"2021-02-25T13:36:36","file_list":["20_29_1016-MCX653106A-HDA_HPE_Ax.pldm.signed","20_29_1016-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"9bf0cebd014b4c2f822c2f784da066e5","name":"20_29_1016-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:33:04","revision":"0","sha1sum":"3e16e70f2da1f1d69a5ba581ed8a979683f69b38","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900345"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"ab42380273374a988dbcb1a25432ed96","version":"8163e8ff503043d3b9272f24d5dd3be8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653106A-HDAT PCIe4 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-05T17:11:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C220A","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters."},{"lang":"ja","x_late":"このコンポーネントは、コンバージドネットワークおよびネットワークのみのアダプターのオペレーティングファームウェアをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29660181","datemodified":"2021-01-22T05:05:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/CP042528.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/brcmflashStandalone-linux-12.0.1336.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/firmware/oc14-12.0.1336.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.02.01-1.8/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP042528.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP042528.scexe"],"md5sum":"5d0e6ed7f65333b9ded0a438830bf6cd","name":"firmware-cna-emulex-2021.02.01-1.8.x86_64.rpm","release":"2021-01-22T04:54:26","revision":"0","sha1sum":"3b5bf17285620850b7b873bc2b7177ab7afc5508","size":"28MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153","a6b1a447-382a-5a4f-10DF-0720103C8144","a6b1a447-382a-5a4f-10DF-0722103C8144","a6b1a447-382a-5a4f-10DF-0724103C8144","a6b1a447-382a-5a4f-10DF-0720103C220A","a6b1a447-382a-5a4f-10DF-0724103C220A","a6b1a447-382a-5a4f-10DF-0722103C220A"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"1c10253696bc48458c2c8df4ff0d1b8d","version":"2348ce5d66cc4b4a9083a6dc2f9d03b9"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"},{"lang":"ja","x_late":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br />\n <br />\n 1. ファームウェアインストレーションツール：rpm -Uhv <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64-bitシステム） </p>\n\n<p> 2. 使用するシステムの適切な場所へcd し、./.setupを実行してファームウェアをアップデートします<br />\n <br />\n ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:43:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p><strong>Firmware</strong></p>\n\n<p>Contains:<br />\nCNA (XE100 series) firmware 12.0.1280.5</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<p>UEFI:</p>\n\n<ul>\n\t<li>HPE FlexFabric 20Gb 2-port 650FLB Adapter and HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;does not complete&nbsp;to create boot source on 2nd port</li>\n</ul>\n\n<p>Firmware:</p>\n\n<ul>\n\t<li>Light Emiiting Diode(LED) is in&nbsp;invalid state when disable the port under Unified Extensible Firmware Interface (UEFI)</li>\n\t<li>Duplicate Entries found in firmware report under NIC details for few adaptors.</li>\n\t<li>Full adapter name is not displayed for HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;in some Rom Based Setup Utility (RBSU).</li>\n\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.</p>\n\n<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6036721","datemodified":"2020-10-30T06:35:10","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/CP046202.xml","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/U19_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u19-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046202.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046202.scexe"],"md5sum":"456716f95c0edac44e86d2c131705288","name":"firmware-system-u19-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-30T06:26:06","revision":"0","sha1sum":"8cda4e92e8eaf9502287a1a65ed96dc6f64917ac","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"6243eef4eb164aedb3860ce40f4d445d","version":"a4c98163f9fe4401bac32d65fb6b00ca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-30T06:23:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:VO1920JEUQQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：VO1920JEUQQのファームウェアを提供します"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n      HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>    <br />\n     None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3323208","datemodified":"2020-12-11T21:21:06","file_list":["cp045580.xml","cpqsetup.exe","HSCPPCD3.rel","payload.json","setup.dll"],"md5sum":"f444fefff4d0705211121597e2f73e93","name":"cp045580.exe","release":"2020-12-11T21:06:09","revision":"0","sha1sum":"129d93a8822a621078b9accec50334236d9a3ffb","size":"3MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"cbed2371ac3f4cd6a3df13f0ee8daa7b","version":"b496abadf7454f42b3bc0d877d1b84d8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO1920JEUQQ Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:02:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2335892","datemodified":"2020-11-20T08:32:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/CP044796.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/hld60404.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.02.01-1.11/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044796.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044796.scexe"],"md5sum":"a209bc8211e9153a32fd8948e42ef90b","name":"firmware-fc-mezz-qlogic-2021.02.01-1.11.x86_64.rpm","release":"2020-11-20T08:22:38","revision":"0","sha1sum":"d6efb7cab738c3c27eb59ceb6b6d90ffa284270e","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"82096ac8d4894962ba9da2e42c289f41","version":"f785df22355c47e382305915fb16d290"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.<br />\n&nbsp;</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb and 16 Gb&nbsp;products.</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td style=\"width:50px\">UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.03.00</td>\n\t\t\t<td>8.08.231</td>\n\t\t\t<td>7.02</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Address unexpected behavior when Fibre Channel adapters were simultaneously running traffic to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n\t<li>Fibre Channel adapter firmware versions were not showing up as expected in the AHS log.</li>\n\t<li>Port statistics counters would sometimes not update in the event of Loss of Signal or Loss of Sync</li>\n\t<li>link downs would occur during specific frame sequences used by the HPE XP8 array after array-side link loss</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_1002-843400-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.1002"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-872723-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-872725-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"18772960","datemodified":"2021-01-25T07:01:30","file_list":["cp045138.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_1002-843400-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","fw-ConnectX5-rel-16_29_1016-872723-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","fw-ConnectX5-rel-16_29_1016-872725-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"37b6b9b8e732838493d624c92aac7ab0","name":"cp045138.exe","release":"2021-01-25T07:00:07","revision":"0","sha1sum":"fe4fd8bda23a1cf8cc6160a7f1b2b4b0b8577656","size":"17MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.0.7"}],"id":{"product":"d626b04e2b74450287a682c2c77ab027","version":"4007c2a7be8f4144bf5cc73e04728513"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:55:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observered while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of the cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>&nbsp;Ani ssue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4303176","datemodified":"2021-01-28T10:05:42","file_list":["./etc/depmod.d/brcmfcoe.conf","./etc/dracut.conf.d/brcmfcoe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"d12078e246fdd66c205e5c96a3b6de44","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-28T09:48:06","revision":"0","sha1sum":"ac6cc2e062d4597631916c6a0091038436f34713","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"de4e8e44a39b461c93ece5604d26abfa","version":"992aaa7de14341ec97fd6c34fa58fda1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 update 3 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:36:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1259.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEPA and MB4000JFEPB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB2000JFEPAおよびMB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17335677","datemodified":"2021-01-28T11:50:36","file_list":["/CP045655_BUILD_7.data","/CP045655.vmexe","/CP045655.vmexe64","/CP045655.vmfile","/CP045655_VMw.zip","/CP045655.xml","/payload.json","/CP045655_VMw.zip/index.xml","/CP045655_VMw.zip/vendor-index.xml","/CP045655_VMw.zip/metadata.zip","/CP045655_VMw.zip/vib20/CP045655/HPE_bootbank_CP045655_HPD5.7-7.0.0.15843807.vib","/CP045655_VMw.zip/metadata.zip/vendor-index.xml","/CP045655_VMw.zip/metadata.zip/vmware.xml","/CP045655_VMw.zip/metadata.zip/vibs/CP045655-5164153973223801411.xml","/CP045655_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045655_HPD5.7-7.0.0.15843807.xml"],"md5sum":"75f4a6796c037881c76726cce9a6cc3b","name":"CP045655.zip","release":"2021-01-28T11:48:05","revision":"0","sha1sum":"9411e16f920f67e33b4135c87c3450fede2a5e66","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP045655","version":"HPD5.7-7.0.0.15843807"}]}],"id":{"product":"41fb5700b0aa44b2bbeca072e083be4b","version":"229190e36c8e41038d9755174ae657c2"},"installation":{"command":"CP040514.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:54:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB&nbsp;and&nbsp; EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"5498503","datemodified":"2020-12-13T08:36:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/CP045383.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/HCFLRCD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045383.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045383.scexe"],"md5sum":"7a30995938878d1ffa9538acb9d97a11","name":"firmware-hdd-31f91b8622-HPD5-8.1.x86_64.rpm","release":"2020-12-13T08:24:05","revision":"0","sha1sum":"87d1ff00e08e7f7263774baa44c349d01c16448a","size":"5MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"99e0afc9d35746928c6cb34efe0c36a4","version":"31bf8f81cd69481c9b7945fe858a3358"},"installation":{"command":"CP040314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:36:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array controller driver component for VMware vSphere 6.7, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE Smartアレイコントローラードライバーコンポーネント for VMware vSphere 6.7。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"187510","datemodified":"2020-12-10T11:36:57","file_list":["/cp042875.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/vendor-index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/vib20/nhpsa/Microsemi_bootbank_nhpsa_67.0072.0.149-1OEM.670.0.0.8169922.vib","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vendor-index.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vmware.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/vibs/nhpsa--4151965318532592019.xml","/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922-offline_bundle-17300270.zip/metadata.zip/bulletins/HPE-nhpsa_67.0072.0.149-1OEM.670.0.0.8169922.xml"],"md5sum":"7ac98ba1812a941f010df9bbec2a7424","name":"cp042875.zip","release":"2021-03-24T00:00:00","revision":"1","sha1sum":"ae6be703d84136b1f71dbc2cfce9d1f193dc9c47","size":"183KB","target_guids":[],"type_of_change":"1","version":"2021.01.01","vib_list":[{"name":"nhpsa","version":"67.0072.0.149-1OEM.670.0.0.8169922"}]}],"id":{"product":"bf1a27517d5b40049d86ae61d3476536","version":"5f0ed977c6754cc99e3518b7db1e038a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">.</a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">を使用して、SPPをUSBキーにコピーします。</a></li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br/>\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller Driver for VMware vSphere 6.7 (Driver Component)."},{"lang":"ja","x_late":"HPE ProLiant Smartアレイコントローラードライバーfor VMware vSphere 6.7 (ドライバーコンポーネント) "}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-25T14:41:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>To add OS support for VMware ESXi 7.0 U1 P02</li>\n</ul>\n","latest_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This release provides the following fixes:</p>\n\n<ul>\n\t<li>Fix failed TUR cmds hung in queue</li>\n\t<li>Fix internal cmd reservation broken</li>\n\t<li>Update for new version number scheme</li>\n\t<li>Fix verbose error messages on common innocuous errors<br />\n\t&nbsp;</li>\n\t<li>Failed logical volumes not being properly handled via offline state.</li>\n\t<li>Scsi sense and status returns are incorrect for some error conditions.</li>\n\t<li>Incorrect &#39;unavailable&#39; status seen during hot-plug recovery.</li>\n\t<li>Displayed target ID is incorrect in some driver log messages.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"nhpsa:67.0072.0.149-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.00"},{"DeviceName":"HPE D2220sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18e2e0d794","Version":"2.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft&nbsp;Windows Server 2019 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2540480","datemodified":"2018-09-24T13:00:07","file_list":["cp037679.xml","cpqsetup.exe","payload.json","setup.dll","She-200.fuf.fw"],"md5sum":"be95c64c559859ebb0ac14cef659962a","name":"cp037679.exe","release":"2018-09-24T17:49:03","revision":"0","sha1sum":"afb9ee49762b41e0f624696be3419a449fa0fb56","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef","b99dfb74-f0bc-464f-b418-cd18e2e0d794"],"type_of_change":"0","version":"2.00"}],"id":{"product":"4bce5935b1b945eda51c9496e5f772b8","version":"19d88394738945caaad5ab99fcb2458b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-24T17:43:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft&nbsp;Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2220sb","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。VO001920KWZQRおよびVO003840KWZQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"9359952","datemodified":"2021-01-20T23:14:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/CP045991.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/GP173300HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045991.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045991.scexe"],"md5sum":"d7910eade72ab99be930d883eaff4e7a","name":"firmware-hdd-2af7385a1e-HPK5-1.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"ee157a43c89f3d376bee239a97fd42f655b17047","size":"8MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"1","version":"HPK5"}],"id":{"product":"18e9f59fd9934421b3a1eafac327542f","version":"1b321da1724a476ea717b25e056031ea"},"installation":{"command":"CP041863.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:17:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EH0300JDYTH, EH0450JDYTK and EH0600JDYTL drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>None.</li>\n</ul>\n"}],"files":[{"bytes":"17409482","datemodified":"2021-01-27T17:54:02","file_list":["/CP045621_BUILD_3.data","/CP045621.vmexe","/CP045621.vmexe64","/CP045621.vmfile","/CP045621_VMw.zip","/CP045621.xml","/payload.json","/CP045621_VMw.zip/index.xml","/CP045621_VMw.zip/vendor-index.xml","/CP045621_VMw.zip/metadata.zip","/CP045621_VMw.zip/vib20/CP045621/HPE_bootbank_CP045621_HPD6.3-7.0.0.15843807.vib","/CP045621_VMw.zip/metadata.zip/vendor-index.xml","/CP045621_VMw.zip/metadata.zip/vmware.xml","/CP045621_VMw.zip/metadata.zip/vibs/CP045621-8433599975506645167.xml","/CP045621_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045621_HPD6.3-7.0.0.15843807.xml"],"md5sum":"05408a5bcd1141765879173de0f5c6d3","name":"CP045621.zip","release":"2021-01-27T17:43:04","revision":"0","sha1sum":"8398f15db8ddb4389eb345c31a93dfb5200fda84","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP045621","version":"HPD6.3-7.0.0.15843807"}]}],"id":{"product":"2311760d35054ca48230493dff4b743b","version":"38017fc23f0043f392a0f70a9e8fbfd6"},"installation":{"command":"CP042726.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:24:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"lang":"ja","x_late":"このコンポーネントは、NVMeドライブを取り外す場合に致命的なNon-Maskable Interrupt (NMI)を修正するためにレジストリの変更をインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"614744","datemodified":"2018-10-02T19:17:52","file_list":["cp035799.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix.msi","nvmefix.cab"],"md5sum":"29b7e47e0fe04728cd120232539cf37e","name":"cp035799.exe","release":"2018-10-03T00:17:03","revision":"0","sha1sum":"efea38ffd19ab187817dfb10c27ee8ed4ed95531","size":"600KB","target_guids":[],"type_of_change":"0","version":"1.0.5.0"}],"id":{"product":"a1a3e71f172a45da8be70ea29ecf3efc","version":"5cfa7432e0f941f8a62f5cb0e80fe790"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 \n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"NVMe Drive Eject NMI Fix for Intel Xeon v3 and Xeon v4 Processors for Windows Server 2012 R2 to Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"6F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-13T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Changed component name to indicate which processors are supported. Systems that already have version 1.0.5.0 installed do not need to install this component.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"}],"sw_keys":[{"name":"nvmeejectfix.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\nvmefix"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000300JWFVB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG000300JWFVB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3024832","datemodified":"2020-12-17T14:08:24","file_list":["cp045489.xml","cpqsetup.exe","payload.json","setup.dll","T14SErD2.rel"],"md5sum":"2fc446ee55ed7cc16afcdb7173c8632c","name":"cp045489.exe","release":"2020-12-17T14:00:15","revision":"0","sha1sum":"02dbdf58feec2d9a7da80cc42c82c32c4d8650fe","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"0","version":"HPD2"}],"id":{"product":"211fcef09ace432ba1e1c0cdad640eeb","version":"6baddd8ca10843a1af59125ca65b8eef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWFVB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:28:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.20"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"ISS_NVMe_BP_PIC_flashV1B20_signed.hex","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.20"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"12092","datemodified":"2018-07-25T01:51:07","file_list":["ISS_NVMe_BP_PIC_flashV1B20.xml","ISS_NVMe_BP_PIC_flashV1B20_signed.hex","payload.json"],"md5sum":"184be3661437924aac60c6c0bef52077","name":"ISS_NVMe_BP_PIC_flashV1B20.fwpkg","release":"2018-07-25T06:50:06","revision":"0","sha1sum":"6e727daf56e23aa0965d565017e7e1053a2c23fd","size":"11KB","target_guids":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"type_of_change":"0","version":"1.20"}],"id":{"product":"aa9211e645514db69ecc4a92d0863429","version":"e2ab85ed3f5f4be0afcab0b49bed5024"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"00000000-0000-0000-0000-00004e564d65","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-04-26T04:46:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"NVMePIC-Gen10","sw_key_expectedpath":"firmware:nvmebackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新電源管理控制器韌體。 "},{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ko","x_late":"이 구성 요소는 전원 관리 컨트롤러 펌웨어를 업데이트합니다. "},{"lang":"cn","x_late":"该组件更新电源管理控制器固件。 "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"755141","datemodified":"2015-05-14T11:14:09","file_list":["/CP026094.vmexe","/CP026094.vmfile","/CP026094.xml","/README.txt"],"md5sum":"0266ff4b77c423a56923408aeb074593","name":"CP026094.zip","release":"2015-05-14T11:17:04","revision":"0","sha1sum":"ccb48c08a6a7e7da0af90eeea322d1305d7abbc0","size":"737KB","target_guids":[],"type_of_change":"1","version":"4.1","vib_list":[]}],"id":{"product":"7fe0be6bb4504cf8abf7b5506059ca0a","version":"a455d6842b1144f399a1073e29a83e6c"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"<p>  重要提示： 此元件要求先載入 CRU 驅動程式，後然才能執行。此外，CRU 驅動程式有最低版本要求。<br />\n <br /> <strong>若要使用適用於 vCenter 的 HP Insight Control：</strong></p>\n<ul>\n <li>   登入 vSphere 用戶端。</li>\n <li>   在詳細目錄樹狀結構中選取伺服器或叢集。</li>\n <li>   按一下「HP Insight Management (HP Insight 管理)」標籤。</li>\n <li>   遵循適用於 vCenter 的 Insight Control 的步驟，使用智慧型元件更新韌體</li>\n <li>   有關適用於 vCenter 的 Insight Control 連結資訊，包含其說明文件： <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   有關「在 HP ProLiant 伺服器中部署與更新 VMware vSphere 5.0 白皮書」的連結，包含如何使用適用於 vCenter 的 Insight Control 以更新韌體的資訊： <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>從目標伺服器上的 VMware ESXi 作業系統更新韌體：</strong></p>\n<ul>\n <li>   在 ESXi 主機上啟用技術支援模式。</li>\n <li>   以 root 身份登入。(您必須以 root 身份才能套用 ROM 更新)。</li>\n <li>   請將智慧型元件置於暫存目錄中。</li>\n <li>   從相同的目錄執行智慧型元件。例如： ./CPXXXXXX.scexe</li>\n <li>   請依照智慧型元件所提示的相關指示進行。</li>\n <li>   在 ESXi 主機上停用技術支援模式</li>\n <li>   如有需要，重新啟動您的系統使更新立即生效。</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"en","x_late":"<p>\n IMPORTANT: This component requires that the CRU driver be loaded before the component can run. Moreover, there is a minimum version requirement for the CRU driver.<br />\n <br />\n <strong>To use HP Insight Control for vCenter :</strong></p>\n<ul>\n <li>\n  Log in to the vSphere Client.</li>\n <li>\n  Select a server or cluster in the inventory tree.</li>\n <li>\n  Click the HP Insight Management tab.</li>\n <li>\n  Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n <li>\n  Link to information about Insight Control for vCenter, including its documentation: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>\n  Link to &ldquo;Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers White Paper&rdquo; that includes information of how to use Insight Control for vCenter to update firmware: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />\n <strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n<ul>\n <li>\n  Enable Tech Support Mode on the ESXi host.</li>\n <li>\n  Login as root. (You must be root in order to apply the ROM update.)</li>\n <li>\n  Place the Smart Component in a temporary directory.</li>\n <li>\n  From the same directory, execute the Smart Component. For example: ./CPXXXXXX.scexe</li>\n <li>\n  Follow the directions given by the Smart Component.</li>\n <li>\n  Disable Tech Support Mode on the ESXi host</li>\n <li>\n  If required, reboot your system for the update to take effect immediately.</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"ko","x_late":"<p>  중요: 이 구성 요소를 사용하려면 구성 요소를 실행하기 전에 CRU 드라이버를 로드해야 합니다. 또한 CRU 드라이버에 대한 최소 버전 요구 사항이 있습니다.<br />\n <br /> <strong>vCenter용 HP Insight Control 사용 방법:</strong></p>\n<ul>\n <li>   vSphere 클라이언트로 로그인합니다.</li>\n <li>   인벤토리 트리에서 서버 또는 클러스터를 선택합니다.</li>\n <li>   HP Insight Management 탭을 클릭합니다.</li>\n <li>   vCenter용 Insight Control 절차에 따라 스마트 구성 요소를 사용하여 펌웨어를 업데이트합니다.</li>\n <li>   문서를 포함하여 vCenter용 Insight Control의 정보의 링크: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   vCenter용 Insight Control을 사용하여 펌웨어를 업데이트하는 방법에 대한 정보가 포함되어 있는 \"HP ProLiant 서버에 VMware vSphere 5.0 배포 및 업데이트 백서\"의 링크: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>대상 서버의 VMware ESXi 운영 체제에서 펌웨어를 업데이트하는 방법:</strong></p>\n<ul>\n <li>   ESXi 호스트에서 Tech Support Mode(기술 지원 모드)를 활성화합니다.</li>\n <li>   루트로 로그인합니다. (ROM 업데이트를 적용하려면 반드시 루트 계정을 사용해야 합니다.)</li>\n <li>   스마트 구성 요소를 임시 디렉터리에 저장합니다.</li>\n <li>   동일한 디렉터리에서 스마트 구성 요소를 실행합니다. 예: ./CPXXXXXX.scexe</li>\n <li>   스마트 구성 요소의 설명에 따라 진행합니다.</li>\n <li>   ESXi 호스트에서 Tech Support Mode(기술 지원 모드)를 비활성화합니다.</li>\n <li>   필요한 경우 업데이트를 즉시 적용하려면 시스템을 다시 부팅합니다.</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"cn","x_late":"<p>  重要信息： 运行该组件前需载入CRU驱动程序。此外，还对CRU驱动程序最低版本有要求。<br />\n <br /> <strong>如要使用 HP Insight Control for vCenter：</strong></p>\n<ul>\n <li>   登录 vSphere 客户端。</li>\n <li>   选择库存树中的服务器或集群。</li>\n <li>   点击 HP Insight Management 选项卡。</li>\n <li>   使用智能组件，按照 Insight Control for vCenter 中的步骤更新固件</li>\n <li>   用于vCenter的Insight控制的信息及其文档，其链接地址是： <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>   “在HP ProLiant服务器上部署和升级VMware vSphere 5.0白皮书”，包括如何使用用于vCenter的Insight控制更新固件，其链接地址是： <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a></li>\n</ul>\n<p>\n <br />  <strong>在运行 VMware ESXi 操作系统的目标服务器上更新固件：</strong></p>\n<ul>\n <li>   启用 ESXi 主机的“技术支持模式”。</li>\n <li>   以根用户身份登录。（必须以根用户身份登录才能应用 ROM 更新。）</li>\n <li>   将 Smart Component 存放到一个临时目录中。</li>\n <li>   在该目录下执行 Smart Component。例如： ./CPXXXXXX.scexe</li>\n <li>   按照 Smart Component 提供的说明执行操作。</li>\n <li>   禁用 ESXi 主机的“技术支持模式”</li>\n <li>   如有要求，请重新启动您的系统以使更改生效。</li>\n</ul>\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>\n 重要： このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。 また、CRUドライバーの最小バージョン要件があります。<br /> <br /> <strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n<ul>\n <li>\n  vSphereクライアントにログインします。</li>\n <li>\n  インベントリツリーのサーバーまたはクラスターを選択します。</li>\n <li>\n  HP Insight Managementタブをクリックします。</li>\n <li>\n  Insight Control for vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います。</li>\n <li>\n  Insight Control for vCenterについてのドキュメントを含む情報へのリンク: <a href=\"http://www.hp.com/go/icvcenter\">http://www.hp.com/go/icvcenter</a></li>\n <li>\n  Insight Control for vCenterを使ってファームウェアをアップデートする方法についての情報を含む、“Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers White Paper”へのリンク: <a href=\"http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf\">http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03285134/c03285134.pdf</a>（英語）</li>\n</ul>\n<p>\n <br /> <strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n<ul>\n <li>\n  ESXiホスト上のTech Support Modeを有効にします。</li>\n <li>\n  rootとしてログインします。 （ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n <li>\n  Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n <li>\n  同じディレクトリからSmartコンポーネントを実行します。 例: ./CPXXXXXX.scexe</li>\n <li>\n  Smartコンポーネントの指示に従います。</li>\n <li>\n  ESXiホスト上のTech Support Modeを無効にします。</li>\n <li>\n  必要な場合、アップデートを直ちに有効にするにはシステムを再起動します。</li>\n</ul>\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新 - 電源管理控制器 "},{"lang":"en","x_late":"Online ROM Flash for VMware ESXi - Power Management Controller "},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 - 전원 관리 컨트롤러 "},{"lang":"cn","x_late":"VMware ESXi版在线ROM刷新 - 电源管理控制器 "},{"lang":"ja","x_late":"オンラインROMフラッシュ for VMware ESXi - Power Management Controller "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2015-03-19T17:33:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>\n <b>Important Notes:</b><br />\n Ver. 4.1(D) contains updates to the OS installation support for HP Smart Update Manager. The Power Management Controller Firmware contained within Ver. 4.1(D) is Ver. 4.1. Therefore, it is not necessary to upgrade with ver. 4.1(D), if the Power Management Controller firmware version is 4.1.<br />\n <b>Firmware Dependencies:</b></p>\nNone\n<p>\n <strong>Enhancements/New Features:</strong><br />\n This is the initial version of the firmware.<br />\n <b><b>Known Issues:</b></b><br />\n The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E) contains updates to the component packaging and is functionally equivalent to ver. 4.1. It is not necessary to upgrade with Revision&nbsp;E if a previous component Revision was used to upgrade the firmware to version 4.1.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HP ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5510346","datemodified":"2020-12-13T08:39:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/CP045384.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/STHBTND6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045384.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045384.scexe"],"md5sum":"29b244c7d0d55fdcc28e876d53906e2b","name":"firmware-hdd-ac3fda26eb-HPD6-8.1.x86_64.rpm","release":"2020-12-13T08:24:12","revision":"0","sha1sum":"23656da6f8fbed429617ca181b0d6646514b7fc9","size":"5MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"b52adb44d0e04f40a015897db8ad0e5d","version":"00123ffa0fe845ec82b1edbe7da66656"},"installation":{"command":"CP040272.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:37:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5519748","datemodified":"2020-12-13T13:25:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/CP045428.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/HAKPNFG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045428.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045428.scexe"],"md5sum":"c68131b652dfe938ccd176702a1856c5","name":"firmware-hdd-70e3962f98-HPG6-8.1.x86_64.rpm","release":"2020-12-13T13:13:04","revision":"0","sha1sum":"2444302d79e767786fba1df275186766d6658757","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"1195ecfa03744617a13d6f9abdc72e2b","version":"77c361a8c15e452fa8afc13119d81eb1"},"installation":{"command":"CP040331.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11690744","datemodified":"2021-01-28T09:30:41","file_list":["cp046635.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_2.42_01_23_2021.signed.flash"],"md5sum":"aff89dca23166916177bb5e6ba31c7f5","name":"cp046635.exe","release":"2021-01-28T09:26:05","revision":"0","sha1sum":"60bedc7736692eaa13eb687656575dccfeeb759d","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"18633ffffaeb4435bcda138419e66c7a","version":"2e686ee183e54553ab6d995be0666da7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br/>\n </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34)サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>BIOS A42_2.40_09_24_2020 needs iLO 5 v2.40 Pass 10 as the minimum supported version.</p>\n"}],"files":[{"bytes":"33811754","datemodified":"2021-02-25T07:07:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/A42_2.40_02_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/CP044531.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.40_2021_02_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044531.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044531.scexe"],"md5sum":"d9d23b2c2427ad529595c47bb560ed38","name":"firmware-system-a42-2.40_2021_02_23-1.1.x86_64.rpm","release":"2021-02-25T07:00:11","revision":"0","sha1sum":"1eb5691988c17adf54f8c05b65418d7757b775e6","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"f201f1f45a1041f9819da1901ffe255f","version":"f0f83ef589d644f184432c9569268d0b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-10T02:42:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16718733","datemodified":"2021-01-27T18:09:57","file_list":["/CP045651_BUILD_3.data","/CP045651.vmexe","/CP045651.vmexe64","/CP045651.vmfile","/CP045651_VMw.zip","/CP045651.xml","/payload.json","/CP045651_VMw.zip/index.xml","/CP045651_VMw.zip/vendor-index.xml","/CP045651_VMw.zip/metadata.zip","/CP045651_VMw.zip/vib20/CP045651/HPE_bootbank_CP045651_HPG4.3-7.0.0.15843807.vib","/CP045651_VMw.zip/metadata.zip/vendor-index.xml","/CP045651_VMw.zip/metadata.zip/vmware.xml","/CP045651_VMw.zip/metadata.zip/vibs/CP045651--3495988391131356465.xml","/CP045651_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045651_HPG4.3-7.0.0.15843807.xml"],"md5sum":"c23053ea300f08234565651b4b99d7b0","name":"CP045651.zip","release":"2021-01-27T18:07:04","revision":"0","sha1sum":"8ca718047ff7cd07d0e2472ac66e67ad465ace23","size":"15MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045651","version":"HPG4.3-7.0.0.15843807"}]}],"id":{"product":"3a074b488c7143aaa5904bb4840ab9e0","version":"ddb33176642b49c3ac1f27b33d7e9555"},"installation":{"command":"CP040507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:50:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5018080","datemodified":"2021-01-21T06:21:43","file_list":["Config.xml","cp045793.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"md5sum":"e90b8a1a75eab59bf562ecb327bdc2c8","name":"cp045793.exe","release":"2021-01-21T06:16:05","revision":"0","sha1sum":"1133da7b910b5154adcc96e296fb04c3e5f8889a","size":"4MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"id":{"product":"bce1dc60182942cc938b19de857de7fd","version":"b8192b6a9afc4ebeb5bbb0ca10e80b6d"},"installation":{"command":"cpqsetup.exe","command_params":"/tD3600 /tD3700 /tD3610 /tD3710 /v5.04 /iReveille-Release-5.04-build-000.bin /lD3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"Windows (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-27T07:25:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12966433","datemodified":"2020-11-23T11:47:01","file_list":["/CP042236_BUILD_6.data","/CP042236.vmexe","/CP042236.vmexe64","/CP042236.vmfile","/CP042236_VMw.zip","/CP042236.xml","/payload.json","/CP042236_VMw.zip/index.xml","/CP042236_VMw.zip/vendor-index.xml","/CP042236_VMw.zip/metadata.zip","/CP042236_VMw.zip/vib20/CP042236/HPE_bootbank_CP042236_2021.02.01.6-6.5.0.4240417.vib","/CP042236_VMw.zip/metadata.zip/vendor-index.xml","/CP042236_VMw.zip/metadata.zip/vmware.xml","/CP042236_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042236_2021.02.01.6-6.5.0.4240417.xml","/CP042236_VMw.zip/metadata.zip/vibs/CP042236--3215076274026879320.xml"],"md5sum":"dbe451a267c9032b8c9566b5e8c89d8c","name":"CP042236.zip","release":"2020-11-23T11:43:04","revision":"0","sha1sum":"703cfca113881851f748b320c22fafcdd3d0a599","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042236","version":"2021.02.01.6-6.5.0.4240417"}]}],"id":{"product":"4b7b12ad9577426297f04a5a3b37c6cd","version":"10216f083659425cafcfe724420d90bb"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:21:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK003840GWHTE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MK003840GWHTEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux&nbsp;(x64)&nbsp;-&nbsp;MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4939784","datemodified":"2020-12-13T14:35:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/CP045449.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/M51004G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045449.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045449.scexe"],"md5sum":"d01d3c535a951cefe97a409cf9b44e21","name":"firmware-hdd-ac20a1e1c6-HPG6-4.1.x86_64.rpm","release":"2020-12-13T14:23:05","revision":"0","sha1sum":"3dc5c4afb8a3d3ddcd9d6e6cddac3701467340a5","size":"4MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"e0a6e611d1444b4f8561da2a0566c408","version":"0b54ea0754d34682977b7ff7c459353d"},"installation":{"command":"CP041322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK003840GWHTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000GWRTCドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5978918","datemodified":"2020-12-13T09:26:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/CP045415.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045415.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045415.scexe"],"md5sum":"d8f21452009dbccb8f3ee09fcc8aa8be","name":"firmware-hdd-82894b9e0a-HPG1-4.1.x86_64.rpm","release":"2020-12-13T09:12:08","revision":"0","sha1sum":"9a56257b2ff5dc5288d6906dca753b5057e4a624","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d7cf155e76584b1f8fb8e3c7c222c90d","version":"60927879ca7a450fbe12b5f9940492d9"},"installation":{"command":"CP041482.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17360728","datemodified":"2021-01-27T12:44:03","file_list":["/CP044982_BUILD_23.data","/CP044982.vmexe","/CP044982.vmexe64","/CP044982.vmfile","/CP044982_VMw.zip","/CP044982.xml","/payload.json","/CP044982_VMw.zip/index.xml","/CP044982_VMw.zip/vendor-index.xml","/CP044982_VMw.zip/metadata.zip","/CP044982_VMw.zip/vib20/CP044982/HPE_bootbank_CP044982_HPD5.23-7.0.0.15843807.vib","/CP044982_VMw.zip/metadata.zip/vendor-index.xml","/CP044982_VMw.zip/metadata.zip/vmware.xml","/CP044982_VMw.zip/metadata.zip/vibs/CP044982--8931448123188660936.xml","/CP044982_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044982_HPD5.23-7.0.0.15843807.xml"],"md5sum":"6a614e430b4f417c019286206439531f","name":"CP044982.zip","release":"2021-01-27T12:41:04","revision":"0","sha1sum":"55ea46153465f8a10549d92a9f0fff781c80d280","size":"16MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP044982","version":"HPD5.23-7.0.0.15843807"}]}],"id":{"product":"d480050a16674bf2aaea0c812270030a","version":"08ff4eb6e58c446e9ee87c5b400ffb37"},"installation":{"command":"CP042538.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-24T08:59:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK&nbsp;and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong> None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16497713","datemodified":"2021-01-28T17:56:52","file_list":["/CP045708_BUILD_4.data","/CP045708.vmexe","/CP045708.vmexe64","/CP045708.vmfile","/CP045708_VMw.zip","/CP045708.xml","/payload.json","/CP045708_VMw.zip/index.xml","/CP045708_VMw.zip/vendor-index.xml","/CP045708_VMw.zip/metadata.zip","/CP045708_VMw.zip/vib20/CP045708/HPE_bootbank_CP045708_HPD9.4-7.0.0.15843807.vib","/CP045708_VMw.zip/metadata.zip/vendor-index.xml","/CP045708_VMw.zip/metadata.zip/vmware.xml","/CP045708_VMw.zip/metadata.zip/vibs/CP045708-132455870593037205.xml","/CP045708_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045708_HPD9.4-7.0.0.15843807.xml"],"md5sum":"586339c6f82c70820bc771816aaccfd7","name":"CP045708.zip","release":"2021-01-28T17:54:05","revision":"0","sha1sum":"785cd2ca4fa36b31861e46716a85a787ea3a38f4","size":"15MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP045708","version":"HPD9.4-7.0.0.15843807"}]}],"id":{"product":"4e3d7926d2c648d2b99239bbce77f310","version":"5599dbd1e31f49f586691795c0e8911b"},"installation":{"command":"CP042779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:40:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 6.7"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.7上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"29288945","datemodified":"2021-02-03T03:54:23","file_list":["/CP045146.vmexe","/CP045146.vmfile","/CP045146_VMw.zip","/CP045146.xml","/payload.json","/CP045146_VMw.zip/index.xml","/CP045146_VMw.zip/vendor-index.xml","/CP045146_VMw.zip/metadata.zip","/CP045146_VMw.zip/vib20/CP045146/HPE_bootbank_CP045146_1.0.1-6.7.0.7535516.vib","/CP045146_VMw.zip/metadata.zip/vendor-index.xml","/CP045146_VMw.zip/metadata.zip/vmware.xml","/CP045146_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045146_1.0.1-6.7.0.7535516.xml","/CP045146_VMw.zip/metadata.zip/vibs/CP045146--1856720601213583088.xml"],"md5sum":"9d2019ca75d79a0d6f1a711e030a0f4a","name":"CP045146.zip","release":"2021-02-03T04:00:05","revision":"0","sha1sum":"f0d0bb392c91c48e0463d093ee332c8fcba5e021","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.4","vib_list":[{"name":"CP045146","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"80a66dc62c31431baffb87b602c0feff","version":"dc1aeece99ff4452bda39fd71e436350"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n\n<p>Note: In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.<br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 6.7"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(ESXi 6.7) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD4"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4820720","datemodified":"2020-12-13T09:00:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/CP045748.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/TA14SXe0HPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045748.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045748.scexe"],"md5sum":"524b64af88ba2896049695db3170b5f6","name":"firmware-hdd-c7df7ceedb-HPD4-3.1.x86_64.rpm","release":"2020-12-13T08:46:29","revision":"0","sha1sum":"5821e5456395026362fb63f4311c3d9124f6375a","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e3abad55c63d42f3bfc00d8212a8e9d4","version":"d45dd9aea61147b88ebf7183fabe585c"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-26T05:59:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"3.53"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"3.53"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"3.53"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"3.53"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"3.53"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"3.53"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"3.53"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408e-m、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;3.53<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;3.21<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;</p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n\n<p>Filesystem or application might read old data when SmartCache configurations that encounter intermittent write I/O errors to a primary logical drive.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     Linux（x64）用追加アップデート/オンラインROMフラッシュコンポーネント - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-a、およびP416ie-m<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n     3.53<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     3.21<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     なし</p>\n\n<p><strong>ファームウェアの依存関係:</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>UBMタイプ3バックプレーンのサポートを追加しました</li>\n\t<li>SATAドライブの長いデバイスモデル/製品IDのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong>     </p>\n\n<p>     </p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">定期的なI/Oの受信中にコントローラーが応答しなくなる可能性がある問題。</li>\n\t<li style=\"list-style-type: disc;\">エキスパンダーの構成中にファームウェアがデバイスを検出しようとし続けるため、ホストI/Oのタイムアウトが発生する可能性があります。</li>\n\t<li style=\"list-style-type: disc;\">サポートされていないブロックサイズの不良ドライブを使用すると、コントローラーのロックアップ問題（コード0x1E10）が発生することがあります。</li>\n\t<li style=\"list-style-type: disc;\">複数のホットプラグおよびホットリムーブイベント（ドライブまたはJBOD）が処理されているときに、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">コントローラーが、フラッシュバックライトキャッシュを有効にした論理ドライブを、論理ドライブの最後に向かってシーケンシャルリードでハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">I/Oが未処理の物理ドライブをホットプラグすると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストI/Oおよびバックグラウンド整合性チェックで、すべてのドライブに同じLBA上でUREが発生しているRAID-1 ADMストライプが同時に検出されると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">ホストがコントローラー構成の消去コマンドまたはその他の構成変更コマンドを発行したときに、RAID6/60論理ドライブのドライブに障害が発生すると、コントローラーがハングアップします。</li>\n\t<li style=\"list-style-type: disc;\">SSDデータドライブは、スペアの再構築が進行しているときにホットリムーブして再挿入すると、オフラインに設定される場合があります（理由コード0x37）。</li>\n\t<li style=\"list-style-type: disc;\">サニタイズ消去が終了した直後にシステムを再起動すると、ドライブがOSに公開されない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">12Gb SAS Expander Cardの特定のポート（ポート7以上）にUBMバックプレーンを接続すると、UBMバックプレーンが正しく検出されません。</li>\n\t<li style=\"list-style-type: disc;\">アイドル状態の後に短時間のI/Oを行うと、コントローラーがハングアップすることがあります。</li>\n\t<li style=\"list-style-type: disc;\">SATAドライブのドライブファームウェアのアップデート後に、コントローラーが以前のドライブファームウェアバージョンを返す場合があります。</li>\n\t<li style=\"list-style-type: disc;\">マルチエキスパンダーエンクロージャー構成でのエキスパンダーファームウェアのアップグレード中に、コントローラーがドライブを障害と見なす可能性があります（理由コード0x49、I/Oフリーズタイムアウトで）。</li>\n\t<li style=\"list-style-type: disc;\">特定のファンアウトエキスパンダータイプの外部エンクロージャーモデルで、ホットアドされたドライブのLED制御が失敗します。</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essentialシリーズコントローラーは、シーケンシャルI/Oを処理しているときに応答せず、ファームウェア合体ロジックがメモリを取得できない場合があります。</li>\n\t<li style=\"list-style-type: disc;\">SmartCache構成でプライマリ論理ドライブへの断続的な書き込みI/Oエラーが発生すると、ファイルシステムまたはアプリケーションが古いデータを読み取る可能性があります。</li>\n</ul>\n\n<p>SmartCache構成でプライマリ論理ドライブへの断続的な書き込みI/Oエラーが発生すると、ファイルシステムまたはアプリケーションが古いデータを読み取る可能性があります。</p>\n\n<p><strong>既知の問題点:</strong><br />\n     なし\n        </p>\n\n<p> </p>\n"}],"files":[{"bytes":"8297385","datemodified":"2021-02-16T12:32:01","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/CP046252.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/HPE_luxor.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-3.53-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046252.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046252.scexe"],"md5sum":"d8191bad377a13b7f516a56f2c3785a5","name":"firmware-smartarray-f7c07bdbbd-3.53-1.1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"1","sha1sum":"6ee4f0adfb45447eefd196983a505c513f64eaa3","size":"7MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"3.53"}],"id":{"product":"02754226ca24415fbdc877dfe47af242","version":"19b36e38f6da4fbb8e3696722a58e96a"},"installation":{"command":"CP046252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP046252.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP046252.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP046252.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./ CP046252.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location （または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"サプリメンタルアップデート/Linux(x64)用オンラインROMフラッシュコンポーネント - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408e-m、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-29T12:58:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while waiting for a non-existent pre-fetch queue entry.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with an unsupported block size is connected into slot 0.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue on DDR caching enabled logical volumes with sequential read towards the end of the volume.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue with outstanding I/Os on a degraded logical volume when the physical drive fails.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS after reboot if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in an expander card configuration.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs issue when processing idle time followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n     </strong>Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <strong> </strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3014256","datemodified":"2020-12-11T11:19:45","file_list":["cp045599.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06ACHPG4.REL"],"md5sum":"dc7dca18f20e004873515d7559041c3d","name":"cp045599.exe","release":"2020-12-11T11:10:04","revision":"0","sha1sum":"60b7ab190de16ca18e8e41e1aa35202e3b05302e","size":"2MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e94dfd89626f4fc992d59a1c00e08f54","version":"d69a6cc7c3084c1fab47e644a306ca31"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:10:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0 includes the latest Fiber Channel and Storage libraries."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6656216","datemodified":"2021-01-19T17:27:46","file_list":["/cp044916.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/index.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/vendor-index.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/metadata.zip","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/vib20/fc-enablement/HPE_bootbank_fc-enablement_700.3.7.0.5-1OEM.700.1.0.15843807.vib","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/metadata.zip/vendor-index.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/metadata.zip/vmware.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/metadata.zip/vibs/fc-enablement-1026333762307423144.xml","/fc-enablement-component_700.3.7.0.5-1_17477831.zip/metadata.zip/bulletins/fc-enablement-component_700.3.7.0.5-1.xml"],"md5sum":"977daf44374af74c8f9d3cb9776fd7a2","name":"cp044916.zip","release":"2021-01-19T17:26:24","revision":"0","sha1sum":"628df928445aa002830ac4b89da1030a7cdab149","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbf0a9496","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"fc-enablement","version":"700.3.7.0.5-1OEM.700.1.0.15843807"}]}],"id":{"product":"f97eb4848b18499fa1a1379ab7b46d05","version":"a04941e9d08f4a53864e41990f761e50"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"6500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports VMware ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"fc-enablement-component:700.3.7.0.5-1","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"fc-enablement:700.3.7.0.5-1OEM.700.1.0.15843807","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2012 R2で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1103024","datemodified":"2021-01-08T19:35:48","file_list":["cp046116.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs64x64.cat","ixs64x64.din","ixs64x64.inf","ixs64x64.sys","ixsmsg.dll","nicco5.dll","nicdrvr.dll","NicInIXS.dll"],"md5sum":"78fc0f96f7b983bfb9307be35fa9ce24","name":"cp046116.exe","release":"2021-01-08T19:22:04","revision":"0","sha1sum":"d0bce2f45134c412abb763abfb35975bf4036a01","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec45933bde"],"type_of_change":"0","version":"3.14.222.0"}],"id":{"product":"6953e0081b4a4f67b00df8e63804d06c","version":"f97501a3ed934331aa675dd41545b3ca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":" Windows Server 2012 R2用HPE Intel ixsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixs64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.2.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1525168","datemodified":"2020-12-03T19:14:06","file_list":["cp044800.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"53091b60f858bc7fa7bbf778b890b9d1","name":"cp044800.exe","release":"2020-12-03T19:04:09","revision":"0","sha1sum":"0db9765491e67832bb80ce22ef2226f447f8fdc2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.2.20"}],"id":{"product":"95f513b0af8c485bb6224e1108f86d03","version":"65014c7645bc4bccabd545bbdb9f2ce3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.1.20</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Memory dumps were not generated during a crash dump in a boot from SAN environment</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.2.20</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"201476","datemodified":"2021-03-08T18:14:57","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"cb1dc8d6f457f65d09afda610476c154","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"1d57731b73fb757dec2755ec6c7e2bc79ea3f5c2","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"201471","datemodified":"2021-03-08T18:10:44","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"06f793669170fc58805b782b3bb411e7","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"7a89299f595cdd2e3fe23b30825d3723930b0a7c","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"571bc8d279024498916baff035cbe35c","version":"06be4bb694964643a6b2119ad4e67d30"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB008000GWRTC drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB008000GWRTCドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18400246","datemodified":"2021-01-28T07:19:32","file_list":["/CP045637_BUILD_3.data","/CP045637.vmexe","/CP045637.vmexe64","/CP045637.vmfile","/CP045637_VMw.zip","/CP045637.xml","/payload.json","/CP045637_VMw.zip/index.xml","/CP045637_VMw.zip/vendor-index.xml","/CP045637_VMw.zip/metadata.zip","/CP045637_VMw.zip/vib20/CP045637/HPE_bootbank_CP045637_HPG1.3-7.0.0.15843807.vib","/CP045637_VMw.zip/metadata.zip/vendor-index.xml","/CP045637_VMw.zip/metadata.zip/vmware.xml","/CP045637_VMw.zip/metadata.zip/vibs/CP045637--4938033830463866540.xml","/CP045637_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045637_HPG1.3-7.0.0.15843807.xml"],"md5sum":"4f7622cdbff5726747fa704286a89b2c","name":"CP045637.zip","release":"2021-01-28T07:16:05","revision":"0","sha1sum":"a50d6c97c426e9ed4c8239e4a283f2a80e7aeb29","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045637","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"a6447acbde7f4368991a3df1503f91e8","version":"02ca93ad6e504ee585b95eb59cc5c1eb"},"installation":{"command":"CP041481.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:39:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.8.9.0.</p>\n"}],"files":[{"bytes":"284001","datemodified":"2020-04-22T11:42:06","file_list":["/cp041435.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/doc/README.txt","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/doc/release_note_ixgben_1.8.9.0-1OEM.700.1.0.15525992.pdf","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/vib20/ixgben/INT_bootbank_ixgben_1.8.9.0-1OEM.700.1.0.15525992.vib","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/vibs/ixgben-6835652811471104199.xml","/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895-package.zip/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992_16039895.zip/metadata.zip/bulletins/Intel-ixgben_1.8.9.0-1OEM.700.1.0.15525992.xml"],"md5sum":"2f757e3cbfd81998bb33d05bb86f3adf","name":"cp041435.zip","release":"2020-04-22T16:41:22","revision":"0","sha1sum":"2e39cedcd48b05250082c3929aad3d47b9daef0b","size":"277KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"0","version":"2020.06.01","vib_list":[{"name":"ixgben","version":"1.8.9.0-1OEM.700.1.0.15525992"}]}],"id":{"product":"026326f2a6e64525ac6b82dd92bae1e8","version":"a4dec67fa9664a5b9252cb1863340f4b"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-27T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-ixgben:1.8.9.0-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"276481","datemodified":"2021-01-09T00:43:11","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"66e8ac8f231ac1500f7e161af589c574","name":"kmod-hp-i40e-2.13.10-1.rhel7u9.x86_64.rpm","release":"2021-01-09T00:35:06","revision":"0","sha1sum":"d4ee0affb7d49133fe8a8fa5d8ab58af00d5b6d2","size":"270KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.13.10-1"},{"bytes":"276485","datemodified":"2021-01-09T00:47:28","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"0f4eee79da1e489192b67cde94d50654","name":"kmod-hp-i40e-2.13.10-1.rhel7u8.x86_64.rpm","release":"2021-01-09T00:35:06","revision":"0","sha1sum":"833c40225b87954769a623207f13bb47fc13a064","size":"270KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"0","version":"2.13.10-1"}],"id":{"product":"3d448885a31a43a9b8495c6b5feb6d8e","version":"d988e0e6b5434a4e83130c8b8b6831df"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product supports new feature called software DCB(Data Center Bridging) which allows using DCB without firmware LLDP(Link Layer Discovery Protocol) agent being turned on.</li>\n\t<li>This product supports new feature which allows user to specify VLAN(Virtual Local Area Network) field and add it to flow director via ethtool</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where server hungs after loading XDP(eXpress Data Path) program in case of LLDP(Link Layer Discovery Protocol) agent disabled&nbsp;</li>\n\t<li>This product addresses an issue where it is not possible to change MAC(Media Access Control) address on VF(Virtual Function) from VM(Virtual Machine) when VF is in trusted mode</li>\n\t<li>This product addresses an issue where it cannot create VF(Virtual Function) VLAN(Virtual Local Area Network) interface inside a namespace&nbsp;</li>\n\t<li>This product addresses an issue where system crash during removing driver when VSI(VIrtual Station Interface) is in reset recovery mode</li>\n\t<li>This product addresses an issue where VF(Virtual Function) receives unicast packets from other VF</li>\n\t<li>This product addresses an issue where using Intel nvmupdate utility never ending update</li>\n\t<li>Thips product addresses an issue where kernel crash in vf driver(iavf) reset when pf driver(i40e) is removing</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, and MB4000GDUPB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, およびMB4000GDUPBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"5219006","datemodified":"2020-12-13T13:21:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/CP045425.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/TAHARRG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045425.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045425.scexe"],"md5sum":"45ea16f2a3781123a4206990953405cc","name":"firmware-hdd-3ab4c70e64-HPG4-9.1.x86_64.rpm","release":"2020-12-13T13:09:05","revision":"0","sha1sum":"bba2b884821b5b2a2780fd32b79564bcd7ff78ae","size":"4MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"be75bc90ea544ceea229c5a0eeef825c","version":"56820fde659f4df79b44e3390f5dfd8f"},"installation":{"command":"CP040288.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"564704","datemodified":"2020-12-07T07:53:16","file_list":["cp046195.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"md5sum":"fbdd0a5846ed62986144f93e8b381980","name":"cp046195.exe","release":"2020-12-07T07:49:04","revision":"0","sha1sum":"fe18e03c1e3563fdffc27bb835cae859f7c66ae7","size":"551KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"type_of_change":"1","version":"12.52.0.676"}],"id":{"product":"e0019db6f6e24588a441b6cb4e743087","version":"d466ff3ae06f4c4a9c3b432b2ae22d66"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />\nSelect &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />\nClick the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Switchtec PCIe Switch Management Driver for Windows Server 2016 and Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"4000","subdev":"4000","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-400011f84000","type":"pci","ven":"11F8"},{"dev":"4052","subdev":"4052","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-405211f84052","type":"pci","ven":"11F8"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-29T15:24:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Support for Apollo 6500 Gen10 Plus XL675d and XL645d</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"}],"sw_keys":[{"name":"Switchtec.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"2066542","datemodified":"2020-09-04T07:03:53","file_list":["/cp045835.xml","/storcli-esxi6.5-bundle-1.25.16.zip","/storcli-esxi6.5-bundle-1.25.16.zip/index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip","/storcli-esxi6.5-bundle-1.25.16.zip/vmware-esx-storcli-1.25.16.vib","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vmware.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vibs/vmware-esx-storcli-1.25.16--1295600419012277576.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/bulletins/HPE-esx-6.5.0-storcli-1.25.16.xml"],"md5sum":"285137ef96fcad68c8e4f1ecf23a90c3","name":"cp045835.zip","release":"2020-09-04T07:03:09","revision":"0","sha1sum":"67c1712ad04f915ef245134655e5cf145b7676da","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf774e4ad"],"type_of_change":"0","version":"2021.04.00","vib_list":[{"name":"vmware-esx-storcli-1.25.16","version":"1.25.16-01"}]}],"id":{"product":"836a010b07664062aae0167a44b26380","version":"f7b8b9e21ea54850ad5ec819ec12f24c"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7/6.5/6.0 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong>~# esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"},{"lang":"ja","x_late":"<p><strong>ESXiシェルからのESXi 6.7/6.5/6.0ホストへのVIBのインストール：</strong></p>\n\n<ul>\n\t<li>ESXiホストのローカルパスへのVIBの転送</li>\n\t<li>ESXiシェルで以下のesxcliコマンドを実行して、VIBをインストールします。</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v=<path><filename.vib> --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIBパッケージは次のコマンドを使用して削除できます</li>\n</ul>\n\n<p><strong>~# esxcli software vib remove -n<strong>=<</strong>filename.vib></strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-04T06:51:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Product&nbsp;Name with the OS version.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vmware-esx-storcli-1.25.16:1.25.16","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"2066298","datemodified":"2020-09-04T07:10:49","file_list":["/cp045812.xml","/storcli-esxi6.7-bundle-1.25.16.zip","/storcli-esxi6.7-bundle-1.25.16.zip/index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip","/storcli-esxi6.7-bundle-1.25.16.zip/vmware-esx-storcli-1.25.16.vib","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vmware.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vibs/vmware-esx-storcli-1.25.16--1295600419012277576.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/bulletins/HPE-esx-6.7.0-storcli-1.25.16.xml"],"md5sum":"604ebf579df2ccc883a16b8fb2a5a6a3","name":"cp045812.zip","release":"2020-09-04T07:10:05","revision":"0","sha1sum":"32b5594a2d06a2939ab03675e6c3c02209eb34b5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf774e4ad"],"type_of_change":"0","version":"2021.04.00","vib_list":[{"name":"vmware-esx-storcli-1.25.16","version":"1.25.16-01"}]}],"id":{"product":"0dff23f4576342a7a89f59feeba0f4a1","version":"4aec688aab964b72b6e3fde17aad5f93"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7&nbsp;host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-01T06:31:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Product&nbsp;Name with the OS version.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vmware-esx-storcli-1.25.16:1.25.16","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"112622","datemodified":"2021-01-17T07:15:49","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"3540fae140010c29bdfdc10671bb0682","name":"tg3-kmp-default-3.139b_k4.12.14_195-2.sles15sp1.x86_64.rpm","release":"2021-01-17T07:08:05","revision":"0","sha1sum":"bf2d54d7cf5a7c7cc82dd11c54d88d7276b00e03","size":"109KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"},{"bytes":"112984","datemodified":"2021-01-17T07:13:10","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"c88102ebdfd665af2905f709fdbb3bcf","name":"tg3-kmp-default-3.139b_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-01-17T07:08:05","revision":"0","sha1sum":"329b24b50b825c9b6c5bb24d3a5e52c36121a1d9","size":"110KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"8e8482d9e6e6494a8e54ec40143d190a","version":"8b3861aed8424b6ba84825a2bb5c6d1f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports sles15 sp1</p>\n","latest_fixes_x_late":"<p>This product fixes an issue where the SLES15 driver be selected by HPSUM deployment for SLES15sp1 OS<br />\nThis product now exports vendor and packager tag in RPM metadata<br />\nThis product addresses the issue where the SLES15 component always be selected by HPSUM deployment</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 8下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"113716","datemodified":"2021-01-17T07:07:35","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/tg3","./lib/modules/4.18.0-193.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/81","./usr/lib/.build-id/81/d9bc30cc5234ec43a2315b6aaafe8c2b0e2b92","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"b7a2cba9a826ba8adf576b7870e4f84f","name":"kmod-tg3-3.139b-1.rhel8u2.x86_64.rpm","release":"2021-01-17T06:56:05","revision":"0","sha1sum":"2f630ae3af01eae4490904202351a8166a9d34a3","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"113723","datemodified":"2021-01-17T07:02:40","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/7927ec8f2d2e366b346d9919d2a10812221738","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"47ce80dcb0ca8c16c25b400e9a204e0f","name":"kmod-tg3-3.139b-1.rhel8u3.x86_64.rpm","release":"2021-01-17T06:56:05","revision":"0","sha1sum":"a59c0d0b5fd9268031783096ce6f84299c41c7ed","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"17ede1952e7d40da9d3235daae0363d6","version":"e6297f5e156d4732b93f943910470377"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 1.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.42.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.42"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14019889","datemodified":"2021-01-29T04:58:55","file_list":["/CP043712_BUILD_50.data","/CP043712.vmexe","/CP043712.vmexe64","/CP043712.vmfile","/CP043712_VMw.zip","/CP043712.xml","/payload.json","/CP043712_VMw.zip/index.xml","/CP043712_VMw.zip/vendor-index.xml","/CP043712_VMw.zip/metadata.zip","/CP043712_VMw.zip/vib20/CP043712/HPE_bootbank_CP043712_1.42.50-7.0.0.15843807.vib","/CP043712_VMw.zip/metadata.zip/vendor-index.xml","/CP043712_VMw.zip/metadata.zip/vmware.xml","/CP043712_VMw.zip/metadata.zip/vibs/CP043712--7624660246222798320.xml","/CP043712_VMw.zip/metadata.zip/bulletins/Smart-Component-CP043712_1.42.50-7.0.0.15843807.xml"],"md5sum":"c42d60372fbdda2bd502449478149372","name":"CP043712.zip","release":"2021-01-29T04:40:04","revision":"0","sha1sum":"c72c040fe35feef49b10efe3d834b85af0236ca3","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.42","vib_list":[{"name":"CP043712","version":"1.42.50-7.0.0.15843807"}]}],"id":{"product":"2cb6e0e14bb34d32a787920ab2722d11","version":"604ce58911ec4ef2a75d6cbceb3879a2"},"installation":{"command":"CP043712.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM1 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-06T06:59:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27739707","datemodified":"2021-02-03T04:40:27","file_list":["/CP044871.vmexe64","/CP044871.vmfile","/CP044871_VMw.zip","/CP044871.xml","/payload.json","/README.txt","/CP044871_VMw.zip/index.xml","/CP044871_VMw.zip/vendor-index.xml","/CP044871_VMw.zip/metadata.zip","/CP044871_VMw.zip/vib20/CP044871/HPE_bootbank_CP044871_1.0.0-7.0.0.15525992.vib","/CP044871_VMw.zip/metadata.zip/vendor-index.xml","/CP044871_VMw.zip/metadata.zip/vmware.xml","/CP044871_VMw.zip/metadata.zip/vibs/CP044871--6883248912506137584.xml","/CP044871_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044871_1.0.0-7.0.0.15525992.xml"],"md5sum":"f2ae7a6bb8c20a77e22ebfacc935de59","name":"CP044871.zip","release":"2021-02-03T04:45:05","revision":"0","sha1sum":"b25f310732635e25b8ca339654fa6de66772299c","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP044871","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"65eb20c47c2e478992fc3cbe0ecae5a8","version":"1cc225eb24184f62ad1d6622d599750f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T11:59:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.27.6008:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when&nbsp;connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>ConnectX-6: 20.27.2008*<br />\n\t\t*Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link&nbsp;speeds.</li>\n\t</ul>\n\t</li>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>Enabled KP4RS FEC on Active Fiber cable up to 30m.</li>\n\t\t<li>FDR protocol.</li>\n\t\t<li>Enabled updating End-to-End (E2E) credit packets instantly.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>There are no new fixes in firmware version 20.27.6008.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.29.1016:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB010000GWAYN and MB008000GWAYL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB010000GWAYNおよびMB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18439371","datemodified":"2021-01-28T07:52:48","file_list":["/CP045639_BUILD_3.data","/CP045639.vmexe","/CP045639.vmexe64","/CP045639.vmfile","/CP045639_VMw.zip","/CP045639.xml","/payload.json","/CP045639_VMw.zip/index.xml","/CP045639_VMw.zip/vendor-index.xml","/CP045639_VMw.zip/metadata.zip","/CP045639_VMw.zip/vib20/CP045639/HPE_bootbank_CP045639_HPG5.3-7.0.0.15843807.vib","/CP045639_VMw.zip/metadata.zip/vendor-index.xml","/CP045639_VMw.zip/metadata.zip/vmware.xml","/CP045639_VMw.zip/metadata.zip/vibs/CP045639--575034058348003122.xml","/CP045639_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045639_HPG5.3-7.0.0.15843807.xml"],"md5sum":"68be3a5cb3707e9a16466df152af2ad4","name":"CP045639.zip","release":"2021-01-28T07:49:05","revision":"0","sha1sum":"7e0ce7b1266ccfe79b9e4db2548ac4214450250e","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP045639","version":"HPG5.3-7.0.0.15843807"}]}],"id":{"product":"d31e8e30285a40108d05d6b3dc709695","version":"e3f4998b35f64c2fa73c4ff4c265db07"},"installation":{"command":"CP040638.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:41:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.&nbsp; This issue was only found in supplier ongoing lab testing.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.  This issue was only found in supplier ongoing lab testing.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16667874","datemodified":"2021-02-11T07:18:09","file_list":["/CP045788_BUILD_39.data","/CP045788.vmcfg","/CP045788.vmexe","/CP045788.vmexe64","/CP045788.vmfile","/CP045788_VMw.zip","/CP045788.xml","/payload.json","/CP045788_VMw.zip/index.xml","/CP045788_VMw.zip/vendor-index.xml","/CP045788_VMw.zip/metadata.zip","/CP045788_VMw.zip/vib20/CP045788/HPE_bootbank_CP045788_5.04.39-7.0.0.15525992.vib","/CP045788_VMw.zip/metadata.zip/vendor-index.xml","/CP045788_VMw.zip/metadata.zip/vmware.xml","/CP045788_VMw.zip/metadata.zip/vibs/CP045788--4044131152736030998.xml","/CP045788_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045788_5.04.39-7.0.0.15525992.xml"],"md5sum":"0f1144c9b36d94972d17f9794773c381","name":"CP045788.zip","release":"2021-02-11T07:15:04","revision":"0","sha1sum":"77cad4d6ded0817eccea3e2df1dbf467ff32c7e3","size":"15MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04","vib_list":[{"name":"CP045788","version":"5.04.39-7.0.0.15525992"}]}],"id":{"product":"cd60e68416444c61a56b3c63cb2d1ca3","version":"e89875cb23e54b388c5423b545561ba0"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"VMware (ESXi)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-27T06:01:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13138859","datemodified":"2020-11-23T11:22:56","file_list":["/CP042549_BUILD_9.data","/CP042549.vmexe","/CP042549.vmexe64","/CP042549.vmfile","/CP042549_VMw.zip","/CP042549.xml","/payload.json","/CP042549_VMw.zip/index.xml","/CP042549_VMw.zip/vendor-index.xml","/CP042549_VMw.zip/metadata.zip","/CP042549_VMw.zip/vib20/CP042549/HPE_bootbank_CP042549_2021.02.01.9-7.0.0.15843807.vib","/CP042549_VMw.zip/metadata.zip/vendor-index.xml","/CP042549_VMw.zip/metadata.zip/vmware.xml","/CP042549_VMw.zip/metadata.zip/vibs/CP042549-7120003748681418251.xml","/CP042549_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042549_2021.02.01.9-7.0.0.15843807.xml"],"md5sum":"4eb92eb8d694f7d8333f79d0b6686d90","name":"CP042549.zip","release":"2020-11-23T11:19:05","revision":"0","sha1sum":"86a38d1e2a83a484b435c52ca655689e864349d9","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042549","version":"2021.02.01.9-7.0.0.15843807"}]}],"id":{"product":"c8a46fd2450f49dda4e8a0e964d64309","version":"8af9eb67b1ec46d294e9cef42c0cdb51"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T09:20:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16850753","datemodified":"2021-01-27T21:35:56","file_list":["/CP045628_BUILD_3.data","/CP045628.vmexe","/CP045628.vmexe64","/CP045628.vmfile","/CP045628_VMw.zip","/CP045628.xml","/payload.json","/CP045628_VMw.zip/index.xml","/CP045628_VMw.zip/vendor-index.xml","/CP045628_VMw.zip/metadata.zip","/CP045628_VMw.zip/vib20/CP045628/HPE_bootbank_CP045628_HPG1.3-7.0.0.15843807.vib","/CP045628_VMw.zip/metadata.zip/vendor-index.xml","/CP045628_VMw.zip/metadata.zip/vmware.xml","/CP045628_VMw.zip/metadata.zip/vibs/CP045628--2509526658557840984.xml","/CP045628_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045628_HPG1.3-7.0.0.15843807.xml"],"md5sum":"175d2b2cd647aa773df5a2e59d58910a","name":"CP045628.zip","release":"2021-01-27T21:33:04","revision":"0","sha1sum":"e92092fea182a4546497db6e60097141f46a5ef8","size":"16MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045628","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"0f2b8614c6ab40aea6c15cd633ff1402","version":"0f809bebbc86404cb2cbc118a3b2bd83"},"installation":{"command":"CP040691.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:32:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"530227","datemodified":"2021-01-28T08:59:11","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"019d2b0233371b54fb22888052aadf8e","name":"kmod-elx-lpfc-12.8.352.11-1.rhel7u8.x86_64.rpm","release":"2021-01-28T08:50:08","revision":"0","sha1sum":"1b29a305bf7491839c3742fe93c0f7981b4cf941","size":"517KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"e72cd1a2f7704ea68d5be6e8ad810600","version":"ba2983dc1ff940d39654c55d20978667"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HPE Smart Update Managerと一緒に使用することが出来ます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;4 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> </p>\n\n<p>iLO 4ユーザーガイドおよびLights-Outスクリプティングガイドは、以下のリンクから入手可能です。<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo\">http://www.hpe.com/info/ilo</a><br />\n<br />\nご使用のLights-Out製品、サポートドキュメント、ドキュメントの順に選択します。<br />\n </p>\n\n<ul>\n\t<li>この機能の使用方法について詳しくは、オンラインヘルプを参照してください。 <br />\n\tオンラインヘルプは、各ページの右上隅のクエスチョンマークをクリックすると、ブラウザーからアクセスできます。</li>\n</ul>\n"}],"files":[{"bytes":"14057859","datemodified":"2020-12-09T12:36:08","file_list":["./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/CP046020.xml","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/ilo4_277.bin","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/readme.txt","./usr/lib/i386-linux-gnu/firmware-ilo4-2.77-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046020.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046020.scexe"],"md5sum":"b68558aa595585ea2424a56ffa6c5d93","name":"firmware-ilo4-2.77-1.1.i386.rpm","release":"2020-12-17T00:00:00","revision":"2","sha1sum":"6dd38e161fc9b290aa9ae35636786e30aa11e6ac","size":"13MB","target_guids":[],"type_of_change":"2","version":"2.77"}],"id":{"product":"d8701885e8a84180a8d83022fac7f1e4","version":"415d0748d7f84f5d8a110a3a54e079cd"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Channel Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]},{"ListConditional":"OR","Requirement":[]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from the Linux operating system on target server:</strong><br />\nDownload the SCEXE file to the target server.<br />\nExecute: sh CP0xxxxx.scexe</p>\n\n<p>&nbsp;<strong>To obtain firmware image for updating via iLO user interface, utilities, or scripting interface:</strong><br />\nDownload the SCEXE file to a client running&nbsp;a Linux operating system.&nbsp; Execute: sh&nbsp; CP0xxxxx.scexe&nbsp;--unpack=directory<br />\nThis command will unpack the ilo4_1XX.bin into a user specified &quot;directory&quot;. If the directory does not exist, the unpacker will attempt to create it.</p>\n\n<p><strong>To use HPE Smart Update Manager on the Firmware Maintenance CD</strong><strong>:</strong><br />\nPlace the Firmware Maintenance CD on a USB key using the HPE USB Key Creator Utility.&nbsp;<br />\nCopy&nbsp; CP0xxxxx.scexe&nbsp;to /compaq/swpackages directory on the USB Key.<br />\nFollow HPE Smart Update Manager steps to complete firmware update.</p>\n\n<p>&nbsp;</p>\n\n<p>Upgrade Requirement:&nbsp;Lowering the severity of the upgrade requirement to Recommended as per the HPE Product Security Policy. It is based on the CVE score for this security vulnerability (7.3), assessment of the impact and the probability of occurrence. So upgrade requirement has been revised to &lsquo;Recommended&rsquo; upgrade.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong><br />\nSCEXEファイルをターゲットサーバーにダウンロードします。<br />\nExecute: sh CP0xxxxx.scexe</p>\n\n<p> <strong>iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイス経由でアップデートするためのファームウェアイメージを取得するには:</strong><br />\nLinuxオペレーティングシステムを実行しているクライアントにSCEXEファイルをダウンロードします。  Execute: sh  CP0xxxxx.scexe --unpack=directory<br />\nこのコマンドにより、ユーザーの指定した「ディレクトリ」にilo4_1XX.binが解凍されます。ディレクトリが存在しない場合は、unpackerは作成を試みます。</p>\n\n<p><strong>Firmware Maintenance CDのHPE Smart Update Managerを使用するには</strong><strong>：</strong><br />\nHPE USB Key Utilityを使用して、Firmware Maintenance CDをUSBキーに格納します。 <br />\nCP0xxxxx.scexeをUSBキーの/compaq/swpackagesディレクトリにコピーします。<br />\nHPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</p>\n\n<p> </p>\n\n<p>アップグレード要件：HPE製品セキュリティポリシーに従って、アップグレード要件の深刻度を推奨に下げます。これは、このセキュリティの脆弱性のCVEスコア（7.3）、影響の評価、および発生の可能性に基づいています。そのため、アップグレード要件が‘推奨’アップグレードに改訂されました。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 4"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 4"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86)","platform":"red_hat_enterprise_linux_client_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-03T08:52:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to display login banner SSH login</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Potential vulnerabilities in network stack. Click <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=hpesbhf04070en_us\">here</a> to know more about the Security Vulnerabilities.</li>\n\t<li>Active directory test may fail during LDAP authentication.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support to display login banner SSH login</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Potential vulnerabilities in network stack. Click <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=hpesbhf04070en_us\">here</a> to know more about the Security Vulnerabilities.</li>\n\t<li>Active directory test may fail during LDAP authentication.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P98","value":"HP ProLiant SL220f Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 SE Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P94","value":"HP ProLiant SL241n Gen8 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P91","value":"HP ProLiant SL240n Gen8 Server - cancelled"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P93","value":"HP ProLiant SL240d Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"RI10","sw_key_expectedpath":"firmware:ilo4"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1971649","datemodified":"2020-12-02T12:43:30","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i915.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-kvmgt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vfio_mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/i915.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/kvmgt.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/mdev.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"ba5e7d17b7bcb067ecc87fe08f44fbc7","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel8u2.x86_64.rpm","release":"2020-12-02T11:20:06","revision":"0","sha1sum":"0b563700bc7da67d61edb53384674ceb82d0c785","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"2390260","datemodified":"2020-12-02T12:46:55","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/18","./usr/lib/.build-id/18/332b02f4374241293f0bb420e770c68f3c16d0","./usr/lib/.build-id/2d","./usr/lib/.build-id/2d/9f2b6693522457d6001995f9100ee6a42de980","./usr/lib/.build-id/3d","./usr/lib/.build-id/3d/da9f5ee5a83ef64be727d2ba7f4a1a778e4211","./usr/lib/.build-id/40","./usr/lib/.build-id/40/7034979799400429a3df2ac5af7233a0a17adc","./usr/lib/.build-id/49","./usr/lib/.build-id/49/928afa8dca860f1462c79f9495c795ef42e953","./usr/lib/.build-id/67","./usr/lib/.build-id/67/191e91e73ff7eacc9f0bd07e977a05c8f55335","./usr/lib/.build-id/73","./usr/lib/.build-id/73/558cad56a05c5c83b4337bfbb70dc058748362","./usr/lib/.build-id/74","./usr/lib/.build-id/74/056c38baee10bd5aefa95f5b98e939a4292b40","./usr/lib/.build-id/87","./usr/lib/.build-id/87/d12cb9bf2e3a4a25f9fcdec5add865b68fcf7c","./usr/lib/.build-id/a2","./usr/lib/.build-id/a2/0aac180c89ee41eab7717eede3503264cccc0c","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/75e77b733b4838f3cc28882d7fe2ca31a3fa31","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/6f2d924e7209f82ba72f52986d33a900588af7","./usr/lib/.build-id/ba","./usr/lib/.build-id/ba/bb0a9dd2e02441d1a22f9194a343b191bdd8de","./usr/lib/.build-id/bd","./usr/lib/.build-id/bd/b08e8c6e274a18d184c97bf14325261680de59","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad","./usr/share/doc/libibumad/AUTHORS","./usr/share/doc/libibumad/COPYING","./usr/share/doc/libibumad/ChangeLog","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/AUTHORS","./usr/share/doc/libibverbs/COPYING","./usr/share/doc/libibverbs/ChangeLog","./usr/share/doc/libibverbs/README","./usr/share/doc/libmlx4","./usr/share/doc/libmlx4/AUTHORS","./usr/share/doc/libmlx4/COPYING","./usr/share/doc/libmlx4/README","./usr/share/doc/libmlx5","./usr/share/doc/libmlx5/AUTHORS","./usr/share/doc/libmlx5/COPYING","./usr/share/doc/libmlx5/README","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/AUTHORS","./usr/share/doc/librdmacm/COPYING","./usr/share/doc/librdmacm/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"22f67b29c16389b46887058789ab6bac","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel8u2.x86_64.rpm","release":"2020-12-02T11:20:06","revision":"0","sha1sum":"8b1a5bdd87d2693576432afea13ecafbede04a58","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"7107cbc4cbe942d083f705a0dc0fece2","version":"1a31828d7bf540a09c5515513d851b47"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-193.el8.x86_64 or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel8u2.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel8u2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 8 update 2 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet) ドライバーfor Red Hat Enterprise Linux 8 Update 2 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6362840","datemodified":"2020-10-28T21:20:20","file_list":["./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/CP046088.xml","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/I36_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-i36-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046088.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046088.scexe"],"md5sum":"2f18120d941411788ce13d54bdfbe5fc","name":"firmware-system-i36-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-28T21:10:05","revision":"0","sha1sum":"69e4528d37cdb7ca428969bf356f580feafdfca0","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"65b84b051d254111871da2f18ceee59a","version":"2eb30aff9f37429bafadc3d23d126783"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager&nbsp;8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要: このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant BL460c Gen9/WS460c Gen9（I36）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Workstation (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:14:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) -&nbsp;HPE&nbsp;Smart Array P824i-p MR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0043(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"11162704","datemodified":"2020-07-17T06:48:25","file_list":["cp044919.xml","cpqsetup.exe","flash_Ctrl_1.00.bat","InstallDLL.dll","MR_FW_3324_16MB.rom","MR_FW_3324_32MB.rom","MR_FW_3324_4MB.rom","payload.json","storcli64.exe"],"md5sum":"0382af19228880baa2c1b0fee9e5475a","name":"cp044919.exe","release":"2020-07-17T06:45:04","revision":"0","sha1sum":"a316864043921bc317193b44271b793a444f9b0a","size":"10MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"1","version":"24.23.0-0043"}],"id":{"product":"c4098b5f60c74084bd367e95f9010c52","version":"70ef2cf304f84ee5bf3810e0fed98cd5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P824i-p MR Gen10"},{"lang":"ja","x_late":"オンラインROM Flashコンポーネント for Windows (x64) - HPE SmartアレイP824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-16T13:43:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixes Firmware&nbsp;downgrade issue</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00101958en_us\" style=\"color:#0563c1; text-decoration:underline\">a00101958en_us</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW UPDATE FOR HPE SR416i-a and SR932i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SRXXX_Gen10p_3.01.00.006.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"3.01.00.006"},{"DeviceName":"PMCI PLDM FW UPDATE FOR HPE SR416i-a and SR932i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SRXXX_Gen10p_3.01.00.006.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"3.01.00.006"},{"DeviceName":"PMCI PLDM FW UPDATE FOR HPE SR416i-a and SR932i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SRXXX_Gen10p_3.01.00.006.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"3.01.00.006"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE SR932i-p and SR416i-a Gen10 Plus Controllers"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"12085747","datemodified":"2021-02-12T05:33:00","file_list":["HPE_SRXXX_Gen10p_3.01.00.006.ilo","HPE_SRXXX_Gen10p_3.01.00.006.xml","payload.json"],"md5sum":"d94cd06038600597d3262631ab5663ed","name":"HPE_SRXXX_Gen10p_3.01.00.006.fwpkg","release":"2021-03-22T00:00:00","revision":"1","sha1sum":"d1d68c98768333b36b22514dcc9cdc3894f13351","size":"11MB","target_guids":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"type_of_change":"1","version":"03.01.00.006"}],"id":{"product":"37b8041b7e7643398842e72c780d3745","version":"a0e2947d38b34c798d7b79234db5f498"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE SR932i-p and SR416i-a Gen10 Plus Controllers"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-27T06:33:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"02941590","sw_key_expectedpath":"firmware"},{"name":"02DC1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component provides support for the HPE Smart Array Gen10 and Gen10Plus E-series and P-series controllers"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"750264","datemodified":"2021-02-19T06:03:42","file_list":["cp044563.xml","cpqsetup.exe","generic.dll","install.xml","smartpqi.cat","smartpqi.DVL.XML","SmartPqi.inf","SmartPqi.md5","SmartPqi.sha3-512","SmartPqi.sys"],"md5sum":"46ae0d7063fc61bf8c072db33c4c9f5b","name":"cp044563.exe","release":"2021-02-19T06:01:30","revision":"0","sha1sum":"c1a1f6881190b7efc3f146fa1e4f1db66cfaceb3","size":"732KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"type_of_change":"1","version":"106.278.0.1043"}],"id":{"product":"7f5cc2735e814d67a516e6e72cb03eec","version":"586dd67a33284f908928a3ab896ac6f8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array Gen10 and Gen10Plus Controller Driver for Windows Server 2012 R2, Windows Server 2016, and Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:02:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Added an enhancement to fix the stale Drive fi&nbsp;rm&nbsp;ware version returned by a Power Shell command.</p>\n","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This release provides the following fixes:&nbsp;</p>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue where the early completion of the SRB_FUNCTION_SHUTDOWN SRB is in dump mode&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">The driver was not setting the feature bit to inform the controller to return a unique WWN ID per SATA drive via Inquiry VPD 0x83 rather then returning WWN ID per SAT drive port.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">While executing HCK CHAOS test,&nbsp;SmartPQI&nbsp;driver crashes with&nbsp;bugcheck&nbsp;0x7A (KERNEL_DATA_INPAGE_ERROR).&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">While rebooting, the&nbsp;SmartPQI&nbsp;driver crashes with&nbsp;bugcheck&nbsp;0xD1&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">An issue&nbsp;where Sleep test causes the&nbsp;SmartPQI&nbsp;driver to trigger a&nbsp;bugcheck&nbsp;0xD1.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue while executing driver disable/reinstall, the&nbsp;SmartPQI&nbsp;driver crashes with&nbsp;bugcheck&nbsp;0xD1&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue where the application hangs due to lost command. When issuing &quot;Get-Disk&quot; from&nbsp;Powershell, the command would eventually hang indefinitely.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed the registry lookup for determining where I/O is completed was using the string&nbsp;&quot;&nbsp;SubmitViaStartIo&nbsp;&quot; instead of &quot;&nbsp;CompleteIoInDpc&nbsp;&quot;.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue where while executing sleep, the windows&nbsp;SmartPQI&nbsp;driver crashes with&nbsp;bugcheck&nbsp;0x7E.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue where the system would BSOD when doing unnecessary initialization of the multi-tag table after declaring controller lockup.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue that causes a DRIVER_POWER_STATE_FAILURE BSOD&nbsp;</p>\n\t</li>\n</ul>\n\n<ul style=\"list-style-type:disc; margin-left:0px; margin-right:0px\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Fixed an issue where assert did not take into account hibernation/sleep mode where the driver limits the max I/O setting.&nbsp;</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>When executing a &ldquo;PCS-E2Launch&rdquo; the system cause stop responding due to the internal controller command accessing the cmdinfo SRB.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"SmartPqi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 15 64-bit to enable the HPE Smart Array P824i-p MR controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"666511","datemodified":"2019-01-23T06:22:19","file_list":["./lib/modules/4.12.14-23-default","./lib/modules/4.12.14-23-default/updates","./lib/modules/4.12.14-23-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"37d156f6a122f3df3d3debe104547425","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles15sp0.x86_64.rpm","release":"2019-01-23T06:23:01","revision":"0","sha1sum":"346ebcc5fc7eacf5549357377ee80ed554320a1b","size":"650KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"064d24a671684c77b993cf50aaac78a7","version":"ff3d86a5886a4a78b2b033fccd5d4745"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-22T09:32:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: VK007680GWSXN drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。VK007680GWSXNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16383486","datemodified":"2021-01-28T12:51:51","file_list":["/CP045685_BUILD_3.data","/CP045685.vmexe","/CP045685.vmexe64","/CP045685.vmfile","/CP045685_VMw.zip","/CP045685.xml","/payload.json","/CP045685_VMw.zip/index.xml","/CP045685_VMw.zip/vendor-index.xml","/CP045685_VMw.zip/metadata.zip","/CP045685_VMw.zip/vib20/CP045685/HPE_bootbank_CP045685_HPG2.3-7.0.0.15843807.vib","/CP045685_VMw.zip/metadata.zip/vendor-index.xml","/CP045685_VMw.zip/metadata.zip/vmware.xml","/CP045685_VMw.zip/metadata.zip/vibs/CP045685-1567376008964079578.xml","/CP045685_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045685_HPG2.3-7.0.0.15843807.xml"],"md5sum":"c4a0ea28dd1aee159c2744794a9f1672","name":"CP045685.zip","release":"2021-01-28T12:49:04","revision":"0","sha1sum":"46dfbb62ba3ef8848f22532ea9da98e24c257918","size":"15MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045685","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"b4be4739aaa741bf83254d24ca921fd7","version":"d23ec803438c4ffeb8ce030a5d30e32a"},"installation":{"command":"CP040787.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:21:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5013204","datemodified":"2020-12-13T16:42:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/CP046323.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/GPM1645ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046323.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046323.scexe"],"md5sum":"befc5e81ef088baa5f1fe5afeedb3957","name":"firmware-hdd-a07a420ed1-HPD4-1.1.x86_64.rpm","release":"2020-12-13T16:30:05","revision":"0","sha1sum":"762a35f4a47ba929aae1e9c993a8faa3c3121027","size":"4MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f12cb892007944f694736d03ec00543c","version":"3fb05e6d4b924fb4956066d5970b7eb1"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T19:37:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104097","datemodified":"2021-01-14T07:28:07","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"c65312308995a9987c35456d7e66344c","name":"kmod-be2net-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"e78856c4655f4915586cb652ef7ba358d9933549","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104185","datemodified":"2021-01-14T07:31:41","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"6ac2fcd892c5adf66e0a4f8489147939","name":"kmod-be2net-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"895872217e5fe34b6726e35585615ab5316c88a2","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7ac9bd0dae24b7e9605737bb695f64d","version":"6b10913d6c864a6592e3e10c90e4fb35"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</li>\n\t<li>This product now supports elx_net_install.sh installation script to install be2net driver on Red Hat Enterprise Linux 8 Update 1 or later.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD4"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD4"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3932968","datemodified":"2020-12-11T18:46:57","file_list":["cp045900.xml","cpqsetup.exe","payload.json","SCIMARRNNSD4.rel","setup.dll"],"md5sum":"45295b502004e36ba3e37d029c64f75b","name":"cp045900.exe","release":"2020-12-11T18:39:04","revision":"0","sha1sum":"3030809f4d69041854f9b3b81f7a84c5426d5fba","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","version":"96f86dd2f93c48e982a3f94cb9ec997d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T12:21:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Dynamic Smart Array controller driver component(hpdsa) for VMware vSphere 6.7, for use with Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"943633","datemodified":"2019-05-08T14:13:08","file_list":["/cp039788.xml","/hpdsa-5.5.0.68.zip","/hpdsa-5.5.0.68.zip/index.xml","/hpdsa-5.5.0.68.zip/vendor-index.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip","/hpdsa-5.5.0.68.zip/scsi-hpdsa-5.5.0.68-1OEM.550.0.0.1331820.x86_64.vib","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vendor-index.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vmware.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/bulletins/hpdsa-5.5.0.68.xml","/hpdsa-5.5.0.68.zip/metadata-hpdsa-5.5.0.68.zip/vibs/scsi-hpdsa--1775945749.xml"],"md5sum":"71ebdf42db5b5352d768d8521d55686d","name":"cp039788.zip","release":"2019-05-08T19:12:01","revision":"0","sha1sum":"3f5c665808d2fa68010daa8888b218e10679fc80","size":"921KB","target_guids":[],"type_of_change":"1","version":"2019.05.01","vib_list":[{"name":"scsi-hpdsa","version":"5.5.0.68-1OEM.550.0.0.1331820"}]}],"id":{"product":"a52a8072bd114cfd99c6c7548b2a473e","version":"9af5fdd36d8b4bf5bc80e46a1491f7ce"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>CD /hp/swpackages and ./hpsum</li>\n\t<li>Select the next button</li>\n\t<li>Click Add Single Target</li>\n\t<li>Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>CD /hp/swpackagesおよび./hpsum</li>\n\t<li>次へボタンを選択します。</li>\n\t<li>シングルターゲットの追加をクリックします。</li>\n\t<li>更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i Controller Driver for VMware vSphere 6.7 (Driver Component)."}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-07T18:01:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes an issue where the driver could report excessive errors in the debug log.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixes an issue where the driver will not upgrade due to the AHCI driver taking priority.</p>\n\n<p>&nbsp;</p>\n\n<p>This issue is only encounter when upgrading to version 2018.10.18&nbsp;(5.5.0.66-1). All other versions are not affected</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"scsi-hpdsa:5.5.0.68-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD7"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD7"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG0600JETKA, EG0900JETKB, and EG1200JETKC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：EG0600JETKA、EG0900JETKB、およびEG1200JETKC対応のファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4743691","datemodified":"2020-12-13T08:38:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/CP045385.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/TA14SED7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD7-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045385.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045385.scexe"],"md5sum":"165f442ae628ea9e3430efd468bd6ac7","name":"firmware-hdd-7505dfb5ae-HPD7-5.1.x86_64.rpm","release":"2020-12-13T08:25:04","revision":"0","sha1sum":"1a744b9b95e48c24f8c87ff446e0e4abec19f05f","size":"4MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"b24d5f9d7d1b43c1891a12ff33223756","version":"750afe0d22cf456780a3ea7f4ae3202b"},"installation":{"command":"CP040286.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:38:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes.\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2226328","datemodified":"2021-01-23T06:33:23","file_list":["cp042623.xml","cpqsetup.exe","payload.json","setup.dll","UBM3_V1.20.hex.fw"],"md5sum":"abbba4faa553bba8e3551b41d952165d","name":"cp042623.exe","release":"2021-01-23T06:20:04","revision":"0","sha1sum":"9e9475dabcb121a0b6637f5a4988425d3f21d4b4","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.20"}],"id":{"product":"a49dd08da845410cb98aa24a3deb45b2","version":"48d7c58bae8b48bf938ccf887cc4cff8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM3 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"2048"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-01-06T15:39:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11375968","datemodified":"2021-01-28T09:29:34","file_list":["cp046620.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_2.42_01_23_2021.signed.flash"],"md5sum":"d889421410e5158f3594e46f2f4587e9","name":"cp046620.exe","release":"2021-01-28T09:25:06","revision":"0","sha1sum":"2fbf932014d1834da2dbc115e0be322c8e15acc6","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"169b01f1c4c245bc854a8424af9a5f85","version":"ec5f43ea94a048908364de846d69b1cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"735824","datemodified":"2020-11-04T08:27:06","file_list":["/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip","/cp044770.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/vibs/lpfc--8663881662166312599.xml","/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922-offline_bundle-17067488.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.317.0-1OEM.670.0.0.8169922.xml"],"md5sum":"06e3ebb32e8ad0f92a727e270746b79f","name":"cp044770.zip","release":"2020-11-04T08:26:08","revision":"0","sha1sum":"0bbeb27fddebde7ea8583d9ffb0af7c9499adea0","size":"718KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"3992c4a617964c62b374bf1d689252da","version":"db0b46a1cfe44d3da8629e3653554869"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:01:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version &nbsp;12.6.182.2</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>One port of an Fibre Channel adapter could not complete to reconnect to storage after storage upgrade if the host system had been online for over 3 months</li>\n\t<li>Turning on 3PAR Persistent Checksum after the host operating system was running would not result in Persistent Checksum being enabled between the adapter and 3PAR array.</li>\n\t<li>Virtual Machines (VMs) could not access certain storage arrays when those arrays were attached to the VM using N-Port ID Virtualization (NPIV)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11366968","datemodified":"2021-01-27T21:55:55","file_list":["cp046681.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_2.42_01_23_2021.signed.flash"],"md5sum":"2c177d57c5d382f3b664c47abde6baa1","name":"cp046681.exe","release":"2021-01-27T21:54:05","revision":"0","sha1sum":"610697236b8bc0e450ec8c915772911a4f33e9c3","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"2e589cc6a48f40eaa0870785c3351832","version":"9880e7bc4a714e3da90ca7b61629d849"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p> </p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230k Gen10 (U37)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T19:55:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB and EH0600JDXBC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15895209","datemodified":"2021-01-27T17:36:03","file_list":["/CP045620_BUILD_4.data","/CP045620.vmexe","/CP045620.vmexe64","/CP045620.vmfile","/CP045620_VMw.zip","/CP045620.xml","/payload.json","/CP045620_VMw.zip/index.xml","/CP045620_VMw.zip/vendor-index.xml","/CP045620_VMw.zip/metadata.zip","/CP045620_VMw.zip/vib20/CP045620/HPE_bootbank_CP045620_HPD5.4-7.0.0.15843807.vib","/CP045620_VMw.zip/metadata.zip/vendor-index.xml","/CP045620_VMw.zip/metadata.zip/vmware.xml","/CP045620_VMw.zip/metadata.zip/vibs/CP045620--5934071358778344490.xml","/CP045620_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045620_HPD5.4-7.0.0.15843807.xml"],"md5sum":"ea4bae7823d67057b03d9ee9c6f0d481","name":"CP045620.zip","release":"2021-01-27T17:33:06","revision":"0","sha1sum":"1412c3c49be705de5ed34e229eda948ab829b34d","size":"15MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP045620","version":"HPD5.4-7.0.0.15843807"}]}],"id":{"product":"d39d0611a5e74799a9f08e5f5809ddba","version":"9e9b966c5dd84e5496dd5443a86b7e04"},"installation":{"command":"CP039429.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:23:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含 Emulex 光纖通道主機匯流排配接卡的 Linux 作業系統上提供對 Smart SAN 的支援套件。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Linux operating systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 Emulex 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Linux 操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、LinuxオペレーティングシステムでEmulexファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"21102","datemodified":"2020-06-18T10:07:29","file_list":["./opt/hpe/elx_smartsan/SmartSAN.sh","./opt/hpe/elx_smartsan/elx_ss_enablement","./opt/hpe/elx_smartsan/readme.txt","./usr/share/smartupdate/hpe-emulex-smartsan-enablement-kit/component.xml"],"md5sum":"53f3576eda697e1ab9af5399f57328b4","name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","release":"2020-06-18T10:04:04","revision":"0","sha1sum":"c0558e92f204a355bd2a4c0b862ed932efccdc1d","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7dd508ef"],"type_of_change":"0","version":"1.0.0.0-4"}],"id":{"product":"63a556e6179b4101ae6472eac493f29b","version":"5e1088f7f0a74be489d1e4b3c9c6a8b2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release. &nbsp;They are&nbsp;now a 64 bit&nbsp;specific kit.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the Emulex&nbsp;Smart SAN enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hpe-emulex-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>For detailed information about configurable components, see the <em>HP Smart Update Manager User Guide </em>at <a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">http://www.hpe.com/support/HP_SUM_UG_en</a>.</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-emulex-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-1.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このリリースではイネーブルメントキットに変更がありました。 現在、64 bit固有のキットになりました。   このコンポーネントをインストールする前に以前のキットをアンインストールすることをおすすめします。<br />\n<br />\nEmulex Smart SANイネーブルメントRPMをアンインストールするには、次のコマンドを使用します：</p>\n\n<p>   # rpm -e hpe-emulex-smartsan-enablement-<version>.noarch.rpm</p>\n\n<p>これは構成可能コンポーネントです。  Smart SAN 機能を有効/無効にするための構成ファイルが必要です。  構成を実行できない場合、Smart SANの現状が記載され、実行が完了します。  それ以上の処置は不要です。</p>\n\n<p>構成コンポーネントについての詳細は、<em>http://www.hpe.com/support/HP_SUM_UG_ja</em>で提供されている<a href=\"http://www.hpe.com/support/HP_SUM_UG_en\">HP Smart Update Managerユーザーガイド</a>を参照してください。</p>\n\n<p><strong>ProLiant の HPE サービス パックの外部コンポーネントの実行</strong>:</p>\n\n<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. インストールするには、プロンプトで以下のコマンドを入力してください：<br />\n<br />\n                    # rpm -ivh hpe-emulex-smartsan-enablement-kit-<version>.x86_64.rpm<br />\n<br />\n                    例：# rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-1.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />\n<br />\n                    Installation complete</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 SmartSAN SmartSAN 啟用套件"},{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Linux"},{"lang":"ko","x_late":"Linux용 Emulex SmartSAN 인에이블먼트 키트"},{"lang":"cn","x_late":"Linux版SmartSAN SmartSAN支持套件"},{"lang":"ja","x_late":"HPE Emulex Smart SAN イネーブルメントキット（Linux）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"338F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c338f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-20T05:27:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to SLES15SP1</p>\n\n<p>Updated to version 1.0.0.0-4</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support to SLES15SP1</p>\n\n<p>Updated to version 1.0.0.0-4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"hpe-emulex-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MM1000GFJTE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17192107","datemodified":"2021-01-28T08:28:50","file_list":["/CP045673_BUILD_5.data","/CP045673.vmexe","/CP045673.vmexe64","/CP045673.vmfile","/CP045673_VMw.zip","/CP045673.xml","/payload.json","/CP045673_VMw.zip/index.xml","/CP045673_VMw.zip/vendor-index.xml","/CP045673_VMw.zip/metadata.zip","/CP045673_VMw.zip/vib20/CP045673/HPE_bootbank_CP045673_HPG5.5-7.0.0.15843807.vib","/CP045673_VMw.zip/metadata.zip/vendor-index.xml","/CP045673_VMw.zip/metadata.zip/vmware.xml","/CP045673_VMw.zip/metadata.zip/vibs/CP045673--6022416329306719582.xml","/CP045673_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045673_HPG5.5-7.0.0.15843807.xml"],"md5sum":"61573879fb585449f5f7104d51a64f81","name":"CP045673.zip","release":"2021-01-28T08:25:06","revision":"0","sha1sum":"95e76b24c31c948da03ce066e364242b756f7c8b","size":"16MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5","vib_list":[{"name":"CP045673","version":"HPG5.5-7.0.0.15843807"}]}],"id":{"product":"c0403221bbc14b609f9dc339f216be5e","version":"f0f7655b9850456fa45c97b78219bdb5"},"installation":{"command":"CP041026.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000GFJTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:12:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF,V K001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、V K001920GWJPH、 VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP および MK001920GWJPQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0. U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"23357067","datemodified":"2021-01-28T18:18:55","file_list":["/CP045721_BUILD_4.data","/CP045721.vmexe","/CP045721.vmexe64","/CP045721.vmfile","/CP045721_VMw.zip","/CP045721.xml","/payload.json","/CP045721_VMw.zip/index.xml","/CP045721_VMw.zip/vendor-index.xml","/CP045721_VMw.zip/metadata.zip","/CP045721_VMw.zip/vib20/CP045721/HPE_bootbank_CP045721_HPG5.4-7.0.0.15843807.vib","/CP045721_VMw.zip/metadata.zip/vendor-index.xml","/CP045721_VMw.zip/metadata.zip/vmware.xml","/CP045721_VMw.zip/metadata.zip/vibs/CP045721-7883015223486522001.xml","/CP045721_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045721_HPG5.4-7.0.0.15843807.xml"],"md5sum":"904f57db3a2fb95823970238e75b1acc","name":"CP045721.zip","release":"2021-01-28T18:15:04","revision":"0","sha1sum":"dec0986dc58b464b9e3f852f7d9ea2eb449d76af","size":"22MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP045721","version":"HPG5.4-7.0.0.15843807"}]}],"id":{"product":"261c2f9a8f584fd69c7ae5c1643322e4","version":"2eb3ed88b6e2493bbea4f42547c5c6e1"},"installation":{"command":"CP042736.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:50:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEQNL and MB6000JEQNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEQNLおよびMB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3656720","datemodified":"2020-12-16T18:06:27","file_list":["cp045547.xml","cpqsetup.exe","HAKPSCDB.rel","payload.json","setup.dll"],"md5sum":"c88b47b5a6be9eef9a6d25927349ec1d","name":"cp045547.exe","release":"2020-12-16T17:56:10","revision":"0","sha1sum":"6d782290cfa3b97d5256adf03034e72124d7fd32","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"b2d8d2ad18164775b6ab15fb40652791","version":"f1c6857461cb46bfb889ef62c3e9a5fa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:48:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n      </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>  </strong>Added<strong> </strong>support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4432456","datemodified":"2020-12-17T06:33:26","file_list":["cp045522.xml","cpqsetup.exe","payload.json","setup.dll","TAGLXYG8.REL"],"md5sum":"75f68bcd2b9b0d665ac7a3b461a7d843","name":"cp045522.exe","release":"2020-12-17T06:21:09","revision":"0","sha1sum":"3c488c871c634bed54d2e991d7d900a239f19ad5","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"15b8ab8f16cc44ddb79fc673833826dc","version":"5cacb7ec8bb545b3ae73d9dc527c47af"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWBXQ and MB008000GWBYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:40:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1319376","datemodified":"2021-01-09T08:26:15","file_list":["cp045010.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"31bcca242202a17fd50097031e7add33","name":"cp045010.exe","release":"2021-01-09T08:07:04","revision":"0","sha1sum":"a1b7f2d4d3011e847a7c50e583dac81478da4469","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"e774fea9b642407a9f2687df296d352e","version":"8dd3d9b9dea24c70998a024a2d8c2510"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iavf68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp;This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5585035","datemodified":"2020-12-13T13:31:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/CP045434.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/HAKPFCGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045434.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045434.scexe"],"md5sum":"a8102ea39eedc9b98bb4c665bad52e60","name":"firmware-hdd-bfc95f0628-HPGB-8.1.x86_64.rpm","release":"2020-12-13T13:19:04","revision":"0","sha1sum":"d1c8af9ac58455cee25ba3eb2ff75ff4b5ad0ee8","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"197f33c3224544b3a3519e65de72192d","version":"587a72128f6e4e988348d9183b89f9d9"},"installation":{"command":"CP040269.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Provides out of band management system with OS-level Agentless Management information and Active Health System events. "},{"lang":"cn","x_late":"提供具有操作系统级Agentless Management信息和Active Health系统事件的带外管理系统。 "},{"lang":"ja","x_late":"帯域管理システム以外を、OS-レベルエージェントレス管理情報とアクティブヘルスシステムのイベントで提供します。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<ul>\n\t<li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li>\n\t<li>Recommend user enables code integrity policy after AMS installed.</li>\n\t<li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li>\n\t<li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />\n\t&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li>\n\t<li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>\n"}],"files":[{"bytes":"10096896","datemodified":"2021-02-18T07:23:20","file_list":["ams.cab","ams.msi","cp046676.xml","cpqsetup.exe","install.xml","MergeModule2012.msi","multisetup.dll","SmaInstall.cab"],"md5sum":"f6d15c4e32179066d659d2df08046d63","name":"cp046676.exe","release":"2021-02-18T07:20:11","revision":"0","sha1sum":"eb530043e72b7c2142e335607d3ad348a0f326ed","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"type_of_change":"0","version":"2.41.0.0"}],"id":{"product":"e9a54d5b255e4c18936eebffaaff1ccf","version":"4bbc727ad175430eb09131efa45b80f4"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the service installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service for Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T07:44:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>1. Fixed the logging issue (It causes a no responding problem when AMS receives IML from iLO).&nbsp;<br />\n2. Fixed unexpected SNMP Trap 11020 health status.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Logical Drive Trap&nbsp;5023.</li>\n\t<li>Added support for new I/O cards.</li>\n\t<li>Changed IDE/SATA interval time from 120 seconds to 60 seconds.</li>\n\t<li>Redirect more iLO security logs to the Windows event system.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed IML was missing NIC link down record if the user unplugs many cables at the same time.</li>\n\t<li>Fixed iLO web GUI missing IPv6 address when Windows Hype-V switch is created.</li>\n\t<li>Fixed a crash issue when AMS is querying iSCSI information.</li>\n\t<li>Fixed incorrect drive status if IDE SATA drive is busy on access.</li>\n\t<li>Fixed incorrect drive status if Windows see&nbsp;the predictive failure drive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ams.exe","sw_key_expectedpath":"%ProgramFiles%\\OEM\\AMS\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 6.5用lsi-mrコントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"196276","datemodified":"2019-12-20T07:05:28","file_list":["/cp042803.xml","/Release_Notes_lsi-mr3-7.706.09.00-1OEM_6.5.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/lsi-mr3-7.706.09.00-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/doc/README.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/doc/release_note_lsi-mr3_7.706.09.00-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/vendor-index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/vib20/lsi-mr3/Avago_bootbank_lsi-mr3_7.706.09.00-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vibs/lsi-mr3-1676736928.xml"],"md5sum":"5ba8a09854f6eba2db3db81a5d66b62d","name":"cp042803.zip","release":"2019-12-20T07:04:05","revision":"0","sha1sum":"3a51bb1ddb08cdf09040d9df62afc427c837be31","size":"191KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"1","version":"2019.12.13","vib_list":[{"name":"lsi-mr3","version":"7.706.09.00-1OEM.650.0.0.4598673"}]}],"id":{"product":"2b02357c33734bfeaaf1c4331f948d7c","version":"67421128b90e425a88d7ffedc6cd163e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":100,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller (64-bit) Driver for vSphere 6.5 (Driver Component)"},{"lang":"ja","x_late":"vSphere 6.5用HPE SmartアレイP824i-p MRコントローラー（64ビット）ドライバー（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-13T06:52:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Addressed a vSAN Fault Tolerance test failure seen in JBOD mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-mr3:7.706.09.00-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"3007716","datemodified":"2021-03-22T15:35:51","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/77d62c1b69d0eb457e21a3e0ab4f62b4b2ab7a","./usr/lib/.build-id/01/77d62c1b69d0eb457e21a3e0ab4f62b4b2ab7a.1","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/255c3696860fbd28bea8b1d2435d652f068032","./usr/lib/.build-id/68","./usr/lib/.build-id/68/73a13fa72040d559ede4d4d0ef13760f7a171a","./usr/lib/.build-id/6b","./usr/lib/.build-id/6b/1460ce801005173b70e007e42ef62d28900ed0","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/c19f236f46c2fadbaddb93fee2935d10acc952","./usr/lib/.build-id/6c/c19f236f46c2fadbaddb93fee2935d10acc952.1","./usr/lib/.build-id/86","./usr/lib/.build-id/86/cee35c52e9e54d502728c115fe8e0503870d9a","./usr/lib/.build-id/86/cee35c52e9e54d502728c115fe8e0503870d9a.1","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/aff063a226089bb7d2217a545332b0cb1ca759","./usr/lib/.build-id/e5","./usr/lib/.build-id/e5/e38599c6ef1dc8192a0bc1a6fb29ca6b599d06","./usr/lib/.build-id/e5/e38599c6ef1dc8192a0bc1a6fb29ca6b599d06.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"4cdc80603d2d432aa9fb77201c5a24bc","name":"amsd-2.4.1-1571.8.rhel8.x86_64.rpm","release":"2021-03-22T15:26:04","revision":"0","sha1sum":"58a3453a1dfb1122981f712e03d19ce8fb40ea7b","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"2","version":"2.4.1"}],"id":{"product":"c8581e07bdde4d5584c0276be971751e","version":"f8ec7c07e1914af789431004056702ec"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-04T16:33:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following item:</p>\n\n<ul>\n\t<li>A customer may experience smad periodically reporting:&nbsp;No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp; Customers experiencing this issue are requested to update to amsd version 2.3.1.&nbsp;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This release contains the following enhancements:</p>\n\n<ul>\n\t<li>Enhance the robust communication with iLO. The enhancement has a proper process exist and OS signal handling.</li>\n\t<li>Enhance the SMA logging system for better recording of the communication events.</li>\n\t<li>The AMSD reports the Open NIC controllers SN to align with iLO for avoiding the un-sync information.</li>\n</ul>\n","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed a small amount of memory leak as outlined in the Customer Advisory,&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\">a00053824en_us</a></li>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp;</li>\n\t<li>The cpqIde service not able to start while the AMSD configuration is agent mode.</li>\n\t<li>Addressed&nbsp;buffer overflow issues in select&nbsp;corner cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.42 (01/23/2021)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33597364","datemodified":"2021-01-28T09:34:23","file_list":["payload.json","U34_2.42_01_23_2021.signed.flash","U34_2.42_01_23_2021.xml"],"md5sum":"4e8aae7b4cbf013856bbf8fff7cce813","name":"U34_2.42_01_23_2021.fwpkg","release":"2021-01-28T09:26:28","revision":"0","sha1sum":"58ea7ced2d560b1c7767a661601d3c71c0449f0d","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"170e9646d84b43c984c43d017aedc665","version":"e4a25f04c2264ba29d2b381b9a421b37"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1265935","datemodified":"2021-03-08T17:57:22","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"8f894c7333713d25045b7d81003e8718","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-03-08T17:52:08","revision":"0","sha1sum":"768cba11a2d3a081d20fb5564eaa97daf0fbefe1","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1230257","datemodified":"2021-03-08T18:03:04","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"ed5ce2007641badc5b50d6a3080d7e35","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-03-08T17:52:08","revision":"0","sha1sum":"a9680ca6e3c8b503249d7aabc2faea76bb987f64","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"29dd95234723495d9d82f8b70f154b42","version":"53ca2f27de6f44cfb3eef34de7fef182"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for Blade QLogic NX2 Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8 Update 0."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8 Update 0で動作するBlade QLogic NX2マルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic NX2 Linux userspace IO daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"98133","datemodified":"2020-02-12T18:41:13","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/b4ad24d1483e26abcb54e79e3a95dc25b0ee46","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"162f76e39416cb707afb129635a69f00","name":"iscsiuio_bl-2.11.5.13-3.rhel8u0.x86_64.rpm","release":"2020-02-12T18:40:08","revision":"0","sha1sum":"fe652747f3fab38dd0b26986a05bf09a84e84eb7","size":"95KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"2a892367c12c496b8bd5b582e399209d","version":"a53f960ade5f4e5f8a0b75722d89ec05"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for Red Hat Enterprise Linux 8 Update 0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK73H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK73H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK73H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK73H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK73H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK73H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK73H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK73H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;MPK73H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"25449173","datemodified":"2021-02-11T15:20:57","file_list":["/CP046468_BUILD_8.data","/CP046468.vmexe","/CP046468.vmexe64","/CP046468.vmfile","/CP046468_VMw.zip","/CP046468.xml","/payload.json","/CP046468_VMw.zip/index.xml","/CP046468_VMw.zip/vendor-index.xml","/CP046468_VMw.zip/metadata.zip","/CP046468_VMw.zip/vib20/CP046468/HPE_bootbank_CP046468_MPK73H5Q.8-7.0.0.15843807.vib","/CP046468_VMw.zip/metadata.zip/vendor-index.xml","/CP046468_VMw.zip/metadata.zip/vmware.xml","/CP046468_VMw.zip/metadata.zip/vibs/CP046468-4925373077953167540.xml","/CP046468_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046468_MPK73H5Q.8-7.0.0.15843807.xml"],"md5sum":"130b4a6d1ee9bc4347e2543426ff2ba6","name":"CP046468.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"48e613a055b98faa5240f09d4883cd5aa30e93a0","size":"24MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"type_of_change":"1","version":"MPK73H5Q","vib_list":[{"name":"CP046468","version":"MPK73H5Q.8-7.0.0.15843807"}]}],"id":{"product":"6a808075e9fa4bc19e7d11fd17511784","version":"c9bed7b8cfef414b87422e6d0d8fb966"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T07:41:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 HPE Gen9 伺服器上的進階功率限定微控制器韌體。"},{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"이 구성 요소는 HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2817527","datemodified":"2021-03-16T00:39:57","file_list":["/CP047167.vmexe","/CP047167.vmexe64","/CP047167.vmfile","/CP047167.xml","/README.txt"],"md5sum":"aa353be6969c5b8b46e2739a249db9a6","name":"CP047167.zip","release":"2021-03-16T05:37:04","revision":"0","sha1sum":"c0f9dd7f8e4cdab55ae09532fe6b22d74250c99d","size":"2MB","target_guids":[],"type_of_change":"0","version":"1.0.9","vib_list":[]}],"id":{"product":"926e3abf2abf49c2929e347ad48989a8","version":"71d88fc5be0b4f3da67415ecaf19480c"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for ESXi 5.1 is 5.0.3.9.</p>\n\n<p>The minimum CRU version for ESXi 5.5 is 5.5.4.1.</p>\n\n<p>The minimum CRU version for ESXi 6.0 is 6.0.8</p>\n\n<p>The minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hp.com/go/spp\">www.hpe.com/go/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>ESXi 5.1の最小CRUバージョンは5.0.3.9です。</p>\n\n<p>ESXi 5.5の最小CRUバージョンは5.5.4.1です。</p>\n\n<p>ESXi 6.0の最小CRUバージョンは6.0.8です。</p>\n\n<p>6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください: <a href=\"http://www.hp.com/go/spp\">www.hpe.com/go/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware ESXi 的 ROM 線上更新 - 適用於 HPE Gen9 伺服器的進階功率限定微控制器韌體"},{"lang":"en","x_late":"Online ROM Flash for VMware ESXi - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 - HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어"},{"lang":"cn","x_late":"用于 VMware ESXi 的在线 ROM 刷新 - 用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"オンラインROMフラッシュ for VMware ESXi - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T05:32:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(J) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision J&nbsp;if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.9(K) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9. It is not necessary to upgrade with Revision K if a previous component Revision was used to upgrade the firmware to version 1.0.9.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems. This fix increases the accuracy of the minimum capping value set during POST.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR, and MS000800KWDUT Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"6795768","datemodified":"2020-12-12T22:21:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/CP045370.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-5.1/spannmK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045370.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045370.scexe"],"md5sum":"05ca1ad3224178f94a25ad6fde47befc","name":"firmware-hdd-95a2e5abcb-HPK4-5.1.x86_64.rpm","release":"2020-12-12T22:09:04","revision":"0","sha1sum":"7a63374ce915beeb448eaebf94842efe7daa68d1","size":"6MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"19705487dac745ff98bd9969d9ff7a10","version":"4587a177c31a4ad8b998ae9b0542f570"},"installation":{"command":"CP040922.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"},{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:17:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO001920KWZQRおよびVO003840KWZQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7545656","datemodified":"2021-01-25T06:23:00","file_list":["cp045992.xml","cpqsetup.exe","GP173300HPK5.rel","payload.json","setup.dll"],"md5sum":"700e8580807b1c19bf100aa502aa6d2f","name":"cp045992.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"d44ba3f0c752359db001eb561ea377cf43e490dd","size":"7MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"1","version":"HPK5"}],"id":{"product":"f6a0af7aeed5453599816388663b56a0","version":"9cf80e2503ec4f6fb4b30c4bfde5ae28"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:19:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5772801","datemodified":"2020-12-18T01:53:37","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/CP046427.xml","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/U22_2.90_11_27_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u22-2.90_2020_11_27-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046427.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046427.scexe"],"md5sum":"3a0b0be6168bebda12f2fe883d660f83","name":"firmware-system-u22-2.90_2020_11_27-1.1.i386.rpm","release":"2020-12-18T01:43:13","revision":"0","sha1sum":"787b0c4eb06551932eb5f4dabc259294517b562c","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020"}],"id":{"product":"39ff5edbf84841ed9b674290e10d1356","version":"8099ce2a0816484f89942763c2799f3e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen9 (U22) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL20 Gen9 (U22)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:10:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"}],"sw_keys":[{"name":"U22","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter&nbsp;(P23664-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000451</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5523859","datemodified":"2021-02-25T13:21:32","file_list":["20_29_1016-MCX653105A-HDA_HPE_Ax.pldm.signed","20_29_1016-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"772ca7663b82e34094a19e62210b7f81","name":"20_29_1016-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:18:04","revision":"0","sha1sum":"474d4d4eea9102aa10bce3273d8e4ef515932f27","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"da435657efe64ff1a664870254b46a1c","version":"8296014148e54d1fa3a85366e03bb0dd"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the FWPKG supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported FWPKG file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Management Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter "}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-12T11:04:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.04.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.04.07"},{"DeviceName":"HPE 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3262","Version":"03.82.00"},{"DeviceName":"HPE 82Q 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3263","Version":"03.82.00"},{"DeviceName":"HPE 84Q 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2532159000FC","Version":"03.82.00"},{"DeviceName":"HPE SN1000Q 16GB 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E7","Version":"06.04.04"},{"DeviceName":"HPE SN1000Q 16GB 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E8","Version":"06.04.04"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12470945","datemodified":"2021-01-21T14:56:29","file_list":["/CP044780_BUILD_24.data","/CP044780.vmexe","/CP044780.vmexe64","/CP044780.vmfile","/CP044780_VMw.zip","/CP044780.xml","/payload.json","/CP044780_VMw.zip/index.xml","/CP044780_VMw.zip/vendor-index.xml","/CP044780_VMw.zip/metadata.zip","/CP044780_VMw.zip/vib20/CP044780/HPE_bootbank_CP044780_2021.02.01.24-6.5.0.4240417.vib","/CP044780_VMw.zip/metadata.zip/vendor-index.xml","/CP044780_VMw.zip/metadata.zip/vmware.xml","/CP044780_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044780_2021.02.01.24-6.5.0.4240417.xml","/CP044780_VMw.zip/metadata.zip/vibs/CP044780-5189691166791039265.xml"],"md5sum":"8373791c74f45fad060817fdbd0bb6e7","name":"CP044780.zip","release":"2021-01-21T14:53:06","revision":"0","sha1sum":"789f627e5f5f510a6e38a5f338c1ce0ec141e2ef","size":"11MB","target_guids":["a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4","a6b1a447-382a-5a4f-1077-2532103C3262","a6b1a447-382a-5a4f-1077-2532103C3263","a6b1a447-382a-5a4f-1077-2532159000FC","a6b1a447-382a-5a4f-1077-2031103C17E7","a6b1a447-382a-5a4f-1077-2031103C17E8","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044780","version":"2021.02.01.24-6.5.0.4240417"}]}],"id":{"product":"1d65ef8868044e08a92676108c2b60af","version":"879e4b916c854b5b8620cdb6a0e0629a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.5"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 6.5用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb,&nbsp;16 Gb and 32 Gb&nbsp;products.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>8Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 3.82.00</li>\n\t\t<li>Firmware 8.08.207</li>\n\t\t<li>UEFI 7.00</li>\n\t\t<li>BIOS 3.56</li>\n\t</ul>\n\t</li>\n\t<li>16Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 6.03.00</li>\n\t\t<li>Firmware 8.08.231</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.43</li>\n\t</ul>\n\t</li>\n\t<li>32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;&nbsp;\n\t<ul>\n\t\t<li>Package 02.03.06</li>\n\t\t<li>Firmware 09.04.01</li>\n\t\t<li>UEFI 7.08</li>\n\t\t<li>BIOS 0.0</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1128272","datemodified":"2021-01-08T15:50:04","file_list":["cp045126.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"ae896d7ebe5944d4eaaa1ce889b4318b","name":"cp045126.exe","release":"2021-01-08T15:36:06","revision":"0","sha1sum":"891e4e6b3fdcf9d650ca1eacf3c09403d2371b49","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"dac1034844fb4856950db71b5b2c959d","version":"84030a6b355e4e88898bcd7a79cd2caa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40ea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"}],"files":[{"bytes":"3341568","datemodified":"2019-10-24T14:37:03","file_list":["/cp039936.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"fa4361c79e2869122c946da143c62bed","name":"cp039936.zip","release":"2019-10-24T19:37:03","revision":"0","sha1sum":"95a8b6c220987ec7f4ee35fe6da18acda5eb4273","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"957f29fa54a8424d9d2bb2a2851bdb01","version":"a32b530800ed48e1b2c6c24bcfddb559"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade ProLiant Intel Gigabit Ethernet NIC ROMイメージをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"9249571","datemodified":"2021-03-31T19:54:09","file_list":["/CP045076_BUILD_10.data","/CP045076.vmexe","/CP045076.vmexe64","/CP045076.vmfile","/CP045076_VMw.zip","/CP045076.xml","/payload.json","/CP045076_VMw.zip/index.xml","/CP045076_VMw.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip","/CP045076_VMw.zip/vib20/CP045076/HPE_bootbank_CP045076_1.2.2.10-7.0.0.15843807.vib","/CP045076_VMw.zip/metadata.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip/vmware.xml","/CP045076_VMw.zip/metadata.zip/vibs/CP045076--3289781217789523104.xml","/CP045076_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045076_1.2.2.10-7.0.0.15843807.xml"],"md5sum":"a79a420777f38e6bb0a58f35d2ea57a6","name":"CP045076.zip","release":"2021-03-31T19:51:05","revision":"0","sha1sum":"f93fe83298834a220ed43d37ef5bb5331bc5da6f","size":"8MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3","vib_list":[{"name":"CP045076","version":"1.2.2.10-7.0.0.15843807"}]}],"id":{"product":"cbe5961cc6764856bfc9b1b69b78fe4d","version":"51c86cb16f4e4611853f4692b84ff444"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティfor VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi&nbsp;7.0.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD2"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD2"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4816323","datemodified":"2020-12-13T08:08:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/CP045377.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/TA15SEn0HPD2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045377.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045377.scexe"],"md5sum":"c3181b04469665c42232c4e48bc1ba9f","name":"firmware-hdd-24fe569b72-HPD2-4.1.x86_64.rpm","release":"2020-12-13T07:56:04","revision":"0","sha1sum":"f45c366a4d008761d7f711043c0b2931dabbc0b1","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"779f4f17fec64b6b9acf9ede668fc68a","version":"167175a76e8b42c8995b657bcfb4541f"},"installation":{"command":"CP041564.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:29:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.44_10_29_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.44 (10/29/2020)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17883496","datemodified":"2020-11-06T02:45:42","file_list":["A40_2.44_10_29_2020.signed.flash","cp046090.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"7f7847a7139726014a157769bacb35b7","name":"cp046090.exe","release":"2020-11-06T02:42:10","revision":"0","sha1sum":"156ca845c1d98f5fcf30794564b03db7ce5f19b3","size":"17MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"2.44_10-29-2020"}],"id":{"product":"f8437d6127664644832d2cd688d58903","version":"e2a50fa7e57f44088604230979e0143a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL385 Gen10 (A40) サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:52:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices. &nbsp;This option would only be used for PCIe Adapters that support his level of bifurcation.&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where the system may hang during boot up after a warm reset from the OS.</p>\n\n<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p>\n\n<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 SP3."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP3で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"101615","datemodified":"2020-02-12T18:42:06","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/57ef6ded0ab349b14e94046722a43e0164dde6","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"0ea3dc41962b9194ccf67a9bd81fb603","name":"iscsiuio_bl-2.11.5.13-3.sles12sp3.x86_64.rpm","release":"2020-02-12T18:41:04","revision":"0","sha1sum":"1ee272253edaa7522a85410489597a367278c8e4","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"fdecd8de3b2448668fbc68e73736a3fc","version":"deac96d1c675459f8f95ac0aa828e2bb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"},{"lang":"ja","x_late":"HPE Blade QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n\n<p>This product addresses an issue where&nbsp;an iSCSI portal is&nbsp;discovered with invalid an VLAN ID.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.7"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"813227","datemodified":"2020-11-20T08:33:20","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp044791.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"c614deffc384fa2133a4c63a810507c7","name":"cp044791.zip","release":"2020-11-20T08:32:29","revision":"0","sha1sum":"e21736faccb0d4524ce69a315e0ffde531e150f8","size":"794KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"f509039a672245dc846e395d9ac11727","version":"f478166f890b440794d978597569a26f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:30:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Driver version 3.1.36.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Improved adapter driver handling of and recovery from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<a href=\"http://•\tImproved adapter driver handling of and recovery from the unexpected behavior described in Customer Advisory titled: “HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us  •\tAttempts to recover from a management processor unresponsive as described in Customer Advisory “a00094722en_us” could lead to a secondary incomplete activity and unexpected termination of process •\tPackets could be malformed when large amounts of traffic is sent to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Attempts to recover from a management processor unresponsive as described in Customer Advisory &ldquo;a00094722en_us&rdquo; could lead to a secondary incomplete activity and unexpected termination of process</li>\n\t<li>Packets could be malformed when large amounts of traffic is sent to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4295552","datemodified":"2021-01-28T10:16:37","file_list":["./etc/depmod.d/brcmfcoe.conf","./etc/dracut.conf.d/brcmfcoe.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/brcmfcoe","./lib/modules/4.18.0-193.el8.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"db3e5b017f0f31dba7ad3b476d7e7ef5","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-28T10:10:05","revision":"0","sha1sum":"c8100f38486d94d99db08e3c0b384a7c4dedbff8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"789441ab6a994564baf44a09d88c7915","version":"ce51844fbdbc4a63a62dc025ac8848f0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 update 2 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T06:12:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"サポートされているHPE Mellanoxアダプターカード用のHPE Mellanox MFTドライバーおよびFirmware Tool。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8915957","datemodified":"2021-02-09T16:26:31","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"2f2bd1ab471b641fccd5cfe6d9cf39f6","name":"mft-4.16.0-105.sles12sp4.x86_64.rpm","release":"2021-02-09T16:15:04","revision":"0","sha1sum":"7495627675b9d83fa508601bc98f9302d7178f5e","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.16"},{"bytes":"20134","datemodified":"2021-02-09T16:22:02","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/mst_pci.ko","./lib/modules/4.12.14-94.41-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"be343e321e69acdf44373de3339369ce","name":"kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-02-09T16:15:04","revision":"0","sha1sum":"b3448c055faa956531b6186ac340a81ed1610bb3","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.16"}],"id":{"product":"fb694776c4964491b586e98c556b93d2","version":"49de3527db9a46e3b6002307ee88ab3e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.16.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm&nbsp; mft-4.16.0-105.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4（AMD64/EM64T）向けのHPE Mellanox MFTドライバーおよびFirmware Tools"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡的 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62160","datemodified":"2021-01-09T00:27:14","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"b34e4fcde12cb44329ac852d7d69c258","name":"kmod-hp-ixgbevf-4.9.3-1.rhel7u8.x86_64.rpm","release":"2021-01-09T00:05:05","revision":"0","sha1sum":"debba862d8bb45b49a42abd0d6bbaca6ed61059d","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"62157","datemodified":"2021-01-09T00:19:54","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"de4fe2bccd2ec5b02a0aafff99d42ff0","name":"kmod-hp-ixgbevf-4.9.3-1.rhel7u9.x86_64.rpm","release":"2021-01-09T00:05:05","revision":"0","sha1sum":"a6a33a48e1d01dea6c36e9149b2981b03795bba4","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"288e2f6737ed4857873f59d466b41139","version":"78cd9574ef4842cc8abee6eb4ef86f92"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 Update 8</li>\n\t<li>This product update Linux kernel documentation and Configure IRQ affinity tools</li>\n</ul>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1472571","datemodified":"2021-01-22T05:42:58","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp044735.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"4ac0b86c5b457f71650f278e754b18da","name":"cp044735.zip","release":"2021-01-22T05:41:35","revision":"0","sha1sum":"33752b0671c42d3d6f7811a29b67600463e8028e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"8853841c6fb24cd98f983bbce280eeca","version":"e8d24c1071c544ecbaca93c77a9bf2e4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.6.182.2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"124725","datemodified":"2021-01-17T06:54:11","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"68a3400416c6f5095b3e711df61e698e","name":"tg3-kmp-default-3.139b_k4.12.14_94.41-2.sles12sp4.x86_64.rpm","release":"2021-01-17T06:50:04","revision":"0","sha1sum":"5f803a3210ccde538583d537b291b248a0bfeafe","size":"121KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"},{"bytes":"112576","datemodified":"2021-01-17T06:56:21","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"62b170947f01ba77c3e183d89dfdfae9","name":"tg3-kmp-default-3.139b_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-01-17T06:50:04","revision":"0","sha1sum":"2f8684ab9e2258a4d8afe13b2a9b9e87ba76e53b","size":"109KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"446098f1e7d240bb85aed0cf4ebd644e","version":"4878a8e954c44a2b85bbd83102b82f62"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3281","Version":"1280A3"},{"DeviceName":"HPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3282","Version":"1280A3"},{"DeviceName":"HPE SN1000E 16Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E4","Version":"12.8.352.12"},{"DeviceName":"HPE SN1000E 16Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E5","Version":"12.8.352.12"},{"DeviceName":"HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197F","Version":"12.8.352.12"},{"DeviceName":"HPE  SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197E","Version":"12.8.352.12"},{"DeviceName":"HPE 84E 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C2238","Version":"1280A3"},{"DeviceName":"HPE SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200159000FB","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"10543149","datemodified":"2021-01-29T06:24:05","file_list":["/CP044729_BUILD_16.data","/CP044729.vmexe","/CP044729.vmexe64","/CP044729.vmfile","/CP044729_VMw.zip","/CP044729.xml","/payload.json","/CP044729_VMw.zip/index.xml","/CP044729_VMw.zip/vendor-index.xml","/CP044729_VMw.zip/metadata.zip","/CP044729_VMw.zip/vib20/CP044729/HPE_bootbank_CP044729_2021.02.01.16-6.7.0.7535516.vib","/CP044729_VMw.zip/metadata.zip/vendor-index.xml","/CP044729_VMw.zip/metadata.zip/vmware.xml","/CP044729_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044729_2021.02.01.16-6.7.0.7535516.xml","/CP044729_VMw.zip/metadata.zip/vibs/CP044729-2119624648081225325.xml"],"md5sum":"789b67b0c94ef92b21d661483411e418","name":"CP044729.zip","release":"2021-01-29T06:19:04","revision":"0","sha1sum":"f264e51d6c3210984cb9de26d02834b78c032837","size":"10MB","target_guids":["a6b1a447-382a-5a4f-10DF-F100103C3281","a6b1a447-382a-5a4f-10DF-F100103C3282","a6b1a447-382a-5a4f-10DF-E200103C17E4","a6b1a447-382a-5a4f-10DF-E200103C17E5","a6b1a447-382a-5a4f-10DF-E200103C197F","a6b1a447-382a-5a4f-10DF-E200103C197E","a6b1a447-382a-5a4f-10DF-F100103C2238","a6b1a447-382a-5a4f-10DF-E200159000FB","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D6","a6b1a447-382a-5a4f-10DF-F400159002D5"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044729","version":"2021.02.01.16-6.7.0.7535516"}]}],"id":{"product":"ebf7ff9c6812476d970ce7cd8ffbe7b6","version":"45aafc1cf8464e5c91f0db8e008dbbf1"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp; have separate components to update fibre channel and converged network adapters.&nbsp;This is a fibre channel&nbsp;update component.</p>\n\n<p><strong>Contains:</strong></p>\n\n<p>32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16/32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>8 Gb HBA Standup firmware 2.10X6<br />\n8 Gb standup universal boot image 12.60a4(12.6.302.0 BIOS, 12.6.284.0 UEFI)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"293371","datemodified":"2021-02-22T14:39:36","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/sbin/nvme","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"752d64928695df310ed2aa9eff16c6f1","name":"HPE-NFC-host-agent-RHEL-1.0-1.x86_64.rpm","release":"2021-02-22T14:36:15","revision":"0","sha1sum":"ec99b3ce223908611f4169dd6703d0e71fa7c793","size":"286KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd07551d5"],"type_of_change":"1","version":"1.0-1"}],"id":{"product":"c48bc2a5906e4288a0300950c2ec6126","version":"220b7a7f7dfd4094b276c1163775759b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for RedHat Enterprise Linux(RHEL) Server -7/8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-22T07:33:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13344624","datemodified":"2021-01-26T22:16:05","file_list":["cp046668.xml","cpqsetup.exe","I41_2.42_01_23_2021.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"345e63ad32df09a3e7f94ba8ab263533","name":"cp046668.exe","release":"2021-01-26T22:14:09","revision":"0","sha1sum":"941a3bec6ec70926417109a059ce003cb2d7f66e","size":"12MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"51d4f5b1652542c6b4d9e256967fc72b","version":"f7be30066fa04aa1afc15d71d9081e34"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p> </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL460c Gen10 (I41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant BL460c Gen10 (I41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64-bit)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T22:25:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB1000GVYZE、MB2000GVYZF、MB3000GVYZHおよびMB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16908542","datemodified":"2021-01-27T17:35:10","file_list":["/CP045649_BUILD_4.data","/CP045649.vmexe","/CP045649.vmexe64","/CP045649.vmfile","/CP045649_VMw.zip","/CP045649.xml","/payload.json","/CP045649_VMw.zip/index.xml","/CP045649_VMw.zip/vendor-index.xml","/CP045649_VMw.zip/metadata.zip","/CP045649_VMw.zip/vib20/CP045649/HPE_bootbank_CP045649_HPG4.4-7.0.0.15843807.vib","/CP045649_VMw.zip/metadata.zip/vendor-index.xml","/CP045649_VMw.zip/metadata.zip/vmware.xml","/CP045649_VMw.zip/metadata.zip/vibs/CP045649--3539763556872749687.xml","/CP045649_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045649_HPG4.4-7.0.0.15843807.xml"],"md5sum":"e1b365304a5cbcc05222ac6368e53603","name":"CP045649.zip","release":"2021-01-27T17:31:15","revision":"0","sha1sum":"fa7a3fec0813c452c1490b59e6ef08c59a39e062","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045649","version":"HPG4.4-7.0.0.15843807"}]}],"id":{"product":"c33dcf4fcf5847ada8c87d0479b6cb3a","version":"d9895c5f9e13456aba96169387baa5ba"},"installation":{"command":"CP040554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:49:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1336.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7607984","datemodified":"2020-12-03T18:55:55","file_list":["brcmflashStandalone-windows-12.0.1336.0-1/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/firmware/oc14-12.0.1336.0.ufi","brcmflashStandalone-windows-12.0.1336.0-1/win/","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/RM.INI","cp042239.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"fba47855eb626ebee3b9b44a38fe351f","name":"cp042239.exe","release":"2020-12-03T18:35:04","revision":"0","sha1sum":"f23af5522956e8bc54422f83e58604ed1bb48f96","size":"7MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"2cfba0d873b646c19a7524c98b475007","version":"a5f7805991004c5dbc1fb7dab4edfb9d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Microsoft Windows Server 2012R2/2016/2019(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:23:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV, and VO3840JFDHA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VO0480JFDGT、VO0960JFDGU、VO1920JFDGVおよびVO3840JFDHAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n <br />\n<strong>Release Version and/or Date:<br />\n      </strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n      </strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>      HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n      </strong>None</p>\n\n<p><strong>Enhancements/New Features: </strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:<br />\n     </strong>None</p>"}],"files":[{"bytes":"3200696","datemodified":"2020-12-11T13:17:20","file_list":["cp045594.xml","cpqsetup.exe","GP1633D9.rel","payload.json","setup.dll"],"md5sum":"45aef15b2a4e8d8811882ae9369a4617","name":"cp045594.exe","release":"2020-12-11T13:07:04","revision":"0","sha1sum":"6f6b83d154ad06767f6bfcd01742904ab77ef7ca","size":"3MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"dc2f3874388f4d969828a39097a550e8","version":"318d02b7b8ba480692b0f1fc9717412b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:07:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"716098","datemodified":"2021-03-22T15:59:06","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"c5606907a326d347d3e8b06770a23c12","name":"hp-ams-2.10.2-876.6.sles12.x86_64.rpm","release":"2021-03-22T15:51:13","revision":"0","sha1sum":"19d7e8353ec6d45d010d6ee07498c3ff09eacd1d","size":"699KB","target_guids":[],"type_of_change":"0","version":"2.10.2"}],"id":{"product":"ce9d04fe2b3e43e88c77633c663ce12b","version":"bad1c2373fd040b486e6f165225397ef"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 SUSE LINUX Enterprise Server 12 的 HPE ProLiant 無代理程式管理服務"},{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for SUSE LINUX Enterprise Server 12"},{"lang":"ko","x_late":"SUSE LINUX Enterprise Server 12용 HPE ProLiant Agentless 관리 서비스"},{"lang":"cn","x_late":"用于SUSE LINUX企业级服务器12的HPE ProLiant无代理管理服务"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-07T12:17:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Enhancements added in this release:</p>\n\n<ul>\n\t<li>Support for SUSE Linux Enterprise Server 12 Service Pack 5&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the Following Items:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added&nbsp;the warning message for users to restart hp-ams service when iLo reset more than twice. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099805en_us\" style=\"color:#0563c1; text-decoration:underline\">a00099805en_us</a>.&nbsp;&nbsp;</li>\n\t<li>When the server detects the physical network cable is plugged or unplugged, hp-ams will send out a trap to notify the administrator about the&nbsp;physical network status change.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.5 includes the latest HPE Common Information Model (CIM) Providers, HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, the HPE Agentless Management Service (AMS), and Fibre Channel(FC) HBA access libraries. \n "},{"lang":"ja","x_late":"HPE ESXiマネジメントSmartコンポーネントfor VMware ESXi 6.5には、最新のHPE Common Information Model (CIM) Provider、HPE Integrated Lights-Out (iLO)ドライバー、HPE Compaq ROM Utility (CRU)ドライバー、HPE Agentless Management Service (AMS)、およびファイバーチャネル (FC) HBAアクセスライブラリが含まれています。\n "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"15654823","datemodified":"2021-02-25T20:43:49","file_list":["/cp046908.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/index.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vendor-index.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/amshelpr-650.11.7.0.10-1.4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/fc-enablement-650.3.6.0.2-4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/amsd-650.11.7.1.3-1.4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/smx-provider-650.03.16.00.4-4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/ilo_650.10.7.0.4-1OEM.650.0.0.4240417.vib","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vendor-index.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vmware.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/amshelpr--3011758093656758260.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/fc-enablement-7401380141358673836.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/cru-6087260586819000143.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/amsd--2273845781025647597.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/smx-provider--7066341665308296940.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/vibs/ilo--424181866709235809.xml","/esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/metadata-esxi6.5uX-mgmt-bundle-3.7.1.2-1.zip/bulletins/esxi6.5uX-mgmt-bundle-3.7.1.2-1.xml"],"md5sum":"297892d2724b4bef2db03e213597f943","name":"cp046908.zip","release":"2021-02-25T20:42:05","revision":"0","sha1sum":"33d54bce07fa1b3fad8a2c9a9095c538d97dd029","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9eccb7b83b0","20a6e8e4-bf33-4c71-a6bf-d9ec2fe8cc78","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2021.04.12","vib_list":[{"name":"amshelpr","version":"650.11.7.0.10-1.4240417"},{"name":"fc-enablement","version":"650.3.6.0.2-4240417"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"},{"name":"amsd","version":"650.11.7.1.3-1.4240417"},{"name":"smx-provider","version":"650.03.16.00.4-4240417"},{"name":"ilo","version":"650.10.7.0.4-1OEM.650.0.0.4240417"}]}],"id":{"product":"955509238bc94896999b8a9beb96f9dc","version":"7385e5e17c374a9ea6a26c6231f7af53"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-12T02:35:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix PSOD exception resulting from repeated failed attempts to communicate to iLO (Gen10 AMS only)</li>\n\t<li>Fix false NVMe disk temperature alerts</li>\n\t<li>Fix missing OS, driver and software info from AHS logs</li>\n\t<li>Fix max and threshold temperature values for SATA disks to prevent fans from running at higher rate</li>\n\t<li>Fix false SATA disk status change alerts</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Reduce&nbsp;Software Inventory cache refresh time to 15 seconds to help resolve OneView online SW update issues without reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"smx-provider:650.03.16.00.4-4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"amshelpr:650.11.7.0.10-1.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:650.10.7.0.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amsd:650.11.7.1.3-1.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"fc-enablement:650.3.6.0.2-4240417","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS2, provides Windows 64-bit support for HPE Smart Array P824i-p MR 64-bit controller"},{"lang":"ja","x_late":"このドライバーMegaSAS2は、HPE SmartアレイP824i-p MR 64-bitコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"1028840","datemodified":"2019-09-24T12:48:35","file_list":["cp038009.xml","cpqsetup.exe","generic.dll","install.xml","megasas2.cat","MegaSAS2.inf","megasas2.pdb","MegaSas2.sys","nodev.inf"],"md5sum":"f574e5414b7ea243e435bb0bf01940ca","name":"cp038009.exe","release":"2019-09-24T12:47:02","revision":"0","sha1sum":"55738b6cd55742c97649298d4b2ac66dd3047c23","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9d4f074d"],"type_of_change":"1","version":"6.714.18.0"}],"id":{"product":"e7a36c6c410640b394ca5fa6b0bcd1f9","version":"1db8fc89c00d46ee821089c4f52a593e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR 64-bit controller driver for Microsoft Windows 2019 edition."},{"lang":"ja","x_late":"Windows 2019エディション用HPE SmartアレイP824i-p MR 64-bitコントローラードライバー。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-30T09:00:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Yet to update.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MegaSas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1411912","datemodified":"2021-01-08T16:19:54","file_list":["cp045129.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"98cd81dfcc3a9aaa95dc687d5d881336","name":"cp045129.exe","release":"2021-01-08T16:06:09","revision":"0","sha1sum":"1c0b683bb8401a92b4317132cecd597b3fa8f6c8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"ed78d2df04834204b8977e0aaa96c64a","version":"321fce2f873a4dd5931ad5a6e469a6f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel i40ebドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40eb68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"14665367","datemodified":"2021-02-03T03:45:23","file_list":["/CP045145.vmexe","/CP045145.vmfile","/CP045145.xml","/payload.json","/README.txt"],"md5sum":"85009e10def52166ae220dcb8cc12b7d","name":"CP045145.zip","release":"2021-02-03T03:50:05","revision":"0","sha1sum":"345893afb626f6ed93d5b6701b26945fedc1681f","size":"13MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.8","vib_list":[]}],"id":{"product":"c1b78da8d92c4109b1ad0059c99cc84f","version":"7475a126df094b9593aff1ae7daca10b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n\n<p>Note: In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.<br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16473239","datemodified":"2021-01-28T19:01:46","file_list":["/CP046321_BUILD_4.data","/CP046321.vmexe","/CP046321.vmexe64","/CP046321.vmfile","/CP046321_VMw.zip","/CP046321.xml","/payload.json","/CP046321_VMw.zip/index.xml","/CP046321_VMw.zip/vendor-index.xml","/CP046321_VMw.zip/metadata.zip","/CP046321_VMw.zip/vib20/CP046321/HPE_bootbank_CP046321_HPD4.4-7.0.0.15843807.vib","/CP046321_VMw.zip/metadata.zip/vendor-index.xml","/CP046321_VMw.zip/metadata.zip/vmware.xml","/CP046321_VMw.zip/metadata.zip/vibs/CP046321-546979608454708300.xml","/CP046321_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046321_HPD4.4-7.0.0.15843807.xml"],"md5sum":"926df534e8bfba1124ad894efee82455","name":"CP046321.zip","release":"2021-01-28T18:59:05","revision":"0","sha1sum":"41c458b4dfabbd0ceebd7f261a435511b4cf0fa3","size":"15MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP046321","version":"HPD4.4-7.0.0.15843807"}]}],"id":{"product":"001e7fbaf67f420ebcb746aae6b4aee2","version":"7fddfef382994aa5a0519a1098511a53"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T19:05:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP4 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP4 x86_64下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22819","datemodified":"2021-02-11T00:35:25","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav16.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"b9ead5601b07c35eaf3e74dffbbeb92a","name":"libbnxt_re-218.0.7.0-sles12sp4.x86_64.rpm","release":"2021-02-11T00:32:05","revision":"0","sha1sum":"13c1ef59e105372ad73edd4e883b67ed8c3e7f59","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"9f0b7493acab4ced83fdf80f7583cdfd","version":"c552a078e5e7474bb80d4e4f8cd3f064"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">受信トレイライブラリと競合する可能性があるHPE Broadcom RoCEライブラリのインストールまたはアップデート中に--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP4"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD4"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD4"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16069615","datemodified":"2021-01-27T17:22:50","file_list":["/CP045619_BUILD_4.data","/CP045619.vmexe","/CP045619.vmexe64","/CP045619.vmfile","/CP045619_VMw.zip","/CP045619.xml","/payload.json","/CP045619_VMw.zip/index.xml","/CP045619_VMw.zip/vendor-index.xml","/CP045619_VMw.zip/metadata.zip","/CP045619_VMw.zip/vib20/CP045619/HPE_bootbank_CP045619_HPD4.4-7.0.0.15843807.vib","/CP045619_VMw.zip/metadata.zip/vendor-index.xml","/CP045619_VMw.zip/metadata.zip/vmware.xml","/CP045619_VMw.zip/metadata.zip/vibs/CP045619--5325392869907995539.xml","/CP045619_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045619_HPD4.4-7.0.0.15843807.xml"],"md5sum":"7857986e1f05c051449f6aa00152818d","name":"CP045619.zip","release":"2021-01-27T17:20:05","revision":"0","sha1sum":"6f7adf9840a9a6735254d48eedb78d216968240d","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045619","version":"HPD4.4-7.0.0.15843807"}]}],"id":{"product":"486d4489346f4ec8a160ad4ef3c94f99","version":"8a049d9b97ac414f96675adc5871debc"},"installation":{"command":"CP041673.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:22:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;for:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3581104","datemodified":"2020-12-16T15:57:55","file_list":["cp044279.xml","cpqsetup.exe","payload.json","SAVGRTG8.rel","setup.dll"],"md5sum":"2adfca726635a79d52193837802e01db","name":"cp044279.exe","release":"2020-12-16T15:49:04","revision":"0","sha1sum":"4017c17de0a47e626f689f32f2cf840684fc23ce","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"54856ac460a544e2985eadac24abf907","version":"f5e7b0f50a7a46d880ee1b8ef58e296b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GEFQV and MM2000GEFRA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-30T09:17:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5862321","datemodified":"2020-12-13T12:52:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/CP045421.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045421.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045421.scexe"],"md5sum":"2b65b8ecaa08a410274c0f64dbaf7f7a","name":"firmware-hdd-6b7ce3da0e-HPG2-5.1.x86_64.rpm","release":"2020-12-13T12:41:05","revision":"0","sha1sum":"2f9ea5164b0a70a4a550356c67bd36ef8f1323f5","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"05a81ac262384916b1fa6e922a6cada6","version":"2e960f0bf1534986be4152bf7be2f43b"},"installation":{"command":"CP041455.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: XP0120GFJSL and XP0240GFJSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。XP0120GFJSLおよびXP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) -  XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPS2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPS2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3582888","datemodified":"2020-12-11T21:50:26","file_list":["ASAXHPS4.rel","cp045583.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"8412076278a6d5a7a6d91fb1e700fcbf","name":"cp045583.exe","release":"2020-12-11T21:42:04","revision":"0","sha1sum":"c2547afc9c90e4a3099c898afab169a8f9db33b9","size":"3MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"c1ebf0647264498cacbe8929505ef3cf","version":"1761a07da5144d82b355829da0bf5c5d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - XP0120GFJSL and XP0240GFJSN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:03:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1212736","datemodified":"2020-12-02T16:16:13","file_list":["cp045176.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"b055f1cd42190cb6b23134bb7415aed5","name":"cp045176.exe","release":"2020-12-02T15:59:22","revision":"0","sha1sum":"70686ff56e186a30c1c78a8ad24ce0de0d105edc","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"1ba8b21e9855422b82a9a544b83e660c","version":"189458f390f640e7815970da71a7de27"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, ixtmsg.dll, nicco5.dll, and nicinitx.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4886959","datemodified":"2020-12-13T16:38:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/CP045485.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045485.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045485.scexe"],"md5sum":"604bb395ccb579211daf5c14a34c1971","name":"firmware-hdd-aef2a690c9-HPG5-5.1.x86_64.rpm","release":"2020-12-13T16:27:08","revision":"0","sha1sum":"708a6873fb01671665a3eaf2fec09e33c639a013","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"29456540dcc74eaf9f223e63cf50eff7","version":"10d4200a0a074ef4b5dae616c10dfe98"},"installation":{"command":"CP040776.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"HPE Insight Management Agents help IT administrators rapidly respond to potential and actual system failures, increase system stability, reduce troubleshooting complexity, and minimize downtime by providing predictive fault management."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"19647376","datemodified":"2021-02-26T08:23:49","file_list":["agents_x64.msi","agntinst.dll","cp041529.xml","cpqmghost_cfg_en.xml","cpqmghost_cfg_ja.xml","cpqsetup.exe","cp_data.xml","cqmghost_cfg.en","cqmghost_cfg.ja","install.xml","vc110rtl-x64-release.msi","vc90sp1rtl-x64-release.msi"],"md5sum":"d78976b462a87cdd73ad03aff6e1450f","name":"cp041529.exe","release":"2021-04-28T00:00:00","revision":"1","sha1sum":"e0e0a3fa69986cee74af7f0513e38fbd4d40745a","size":"18MB","target_guids":[],"type_of_change":"0","version":"11.1.0.0"}],"id":{"product":"C8627","version":"2befeb38cce44ea1b85d5cacfef1aa85"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb0c60beb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 3/4 Management Controller Driver Package for Windows (Gen 7 or later)"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2c83f673","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 2 Management Controller Driver for Windows (G6 or earlier)"}]},{"ListConditional":"AND","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP System Management Homepage for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1b3359b0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP System Management Homepage for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant PCI Hot Plug Controller Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca134477","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant PCI Hot Plug Controller Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d6a8690","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Board Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9ecb0f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec043b810e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Remote Insight Lights-Out II Board Driver for Windows"},{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Rack Infrastructure Interface Service for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3c85d0a3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Rack Infrastructure Interface Service for Windows"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"snmp Service","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb317c36a","ServerModel":["*"],"Target_guids":[],"Type":"EQ","Version":"*","description":"snmp Service"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC31xx Fast Ethernet NIC Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec0458ccd6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC31xx Fast Ethernet NIC Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec29a79e49","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec83d2dd89","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8b37898c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec82a27969","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc2ac73ef","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7bc999f9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6e1a64e9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec86615221","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec09e99f10","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe73cc6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec76564025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec431d2047","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbbd7533a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd765f4f8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows x64 Editions","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec99544f42","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows x64 Editions"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC51xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec10a1b876","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC51xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC52xx NetXen Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf2c2c1fe","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC52xx NetXen Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca203699c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9814091f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Intel N1E Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec013cb3c5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Intel N1E Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4efaf7b6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 1Gb Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 1Gb Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecba1ae635","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBeforeIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP NC-Series Broadcom 10GbE Multifunction Driver for Windows"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. From that drive and directory, execute the downloaded file. Click the \"Install\" button to proceed with the installation. The agents will automatically be installed."},{"lang":"ja","x_late":"スマート コンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、スマート コンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。 そのドライブ、ディレクトリから、ダウンロードしたファイルを実行します。 インストール ボタンをクリックして、インストールを開始します。 エージェントは自動的にインストールされます。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Insight Management Agents for Microsoft Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"25000"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-05-29T06:13:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed multiple event ID 1182 issue</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed unusual Windows system events originating from SNMP network agents</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"agentver.dll","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt"},{"name":"cpqnimgt.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqnimgt"},{"name":"cqmgserv.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmgserv"},{"name":"cqmgstor.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmgstor"},{"name":"cqmghost.exe","sw_key_expectedpath":"%systemroot%\\system32\\cpqmgmt\\cqmghost"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"427903","datemodified":"2021-01-28T10:54:23","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"2de4572c4ff1d655582470f849db5890","name":"brcmfcoe-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-28T10:52:05","revision":"0","sha1sum":"24b88e09e4d77a34d6a43d3928034235f836a418","size":"417KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"84051890e0514293b965776dfe88fd04","version":"2646888ffd7e4a339ceed66cbcc3b6bb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 service pack 1 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T06:17:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 (64-bit) to enable the HPE H2xx SAS/SATA Host Bus Adapter.  This RPM provides a customer friendly approach to install a\npre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE H2xx SAS/SATAホストバスアダプターを有効にする、SUSE LINUX Enterrise Server 12（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1063589","datemodified":"2018-12-13T09:12:23","file_list":["./etc/modprobe.d/mpt3sas.conf","./lib/modules/4.12.14-94.37-default","./lib/modules/4.12.14-94.37-default/updates","./lib/modules/4.12.14-94.37-default/updates/mpt2sas.ko","./usr/share/smartupdate/lsi-mpt2sas-kmp-default/component.xml"],"md5sum":"9785557a0564fc9a1ad760f2e1f7799c","name":"lsi-mpt2sas-kmp-default-15.10.09.00-1.sles12sp4.x86_64.rpm","release":"2018-12-13T09:13:08","revision":"0","sha1sum":"cf7146998ba594a8d11b3e8bce01ed70871906bd","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-1"}],"id":{"product":"fbd21bfdc4ac48d1a1f00173d5e23ce2","version":"231836b382694cd5891ddf6311951fb5"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-x represents the version numberand N represents the OS Update number)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-x represents the version number and and N represents the OS Update number)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n\n<p>Note: If HPE System Insight Manager support is required, install the latest Service Pack for ProLiant and<br />\nlsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm after the OS has completed its installation process and system has rebooted.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nセットアップが完了したらコンピュータをリブートする必要があります。</p>\n\n<p>注：HPE System Insight Managerサポートが必要な場合は、OSがインストールを完了してシステムが再起動した後で、ProLiant用の最新のサービスパックおよび<br />\nOSがインストレーションプロセスを完了し、システムがリブートした後で、lsi-mpt2sas-kmp-X.X.X.X-X.sles12spN.x86_64.rpmをインストールします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for SUSE LINUX Enterprise Server 12 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterrise Server 12（64-bit）用HPE H2xx SAS/SATAバスアダプタードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0070","subdev":"0046","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0044","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0043","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0041","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T09:10:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Address the Linux Spectre Variant 2 Vulnerability Issue</p>\n"},{"curr_enhancements_x_late":"<p>Added support for&nbsp;SUSE Linux Enterprise Server 12 SP4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P81","value":"HP ProLiant DL380p Gen8 SE Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"}],"sw_keys":[{"name":"lsi-mpt2sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n"}],"files":[{"bytes":"6273695","datemodified":"2020-12-13T09:25:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/CP045413.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/TAGLXYG8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045413.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045413.scexe"],"md5sum":"d9f8c8b2d19d2e3bb21dfc8994821e75","name":"firmware-hdd-a1fd19f9ca-HPG8-5.1.x86_64.rpm","release":"2020-12-13T09:11:04","revision":"0","sha1sum":"9aa87a57c9865b3c5d5ca509d337db3260ec23ea","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"2e44a81a31b2430ba5be31f73e9e365e","version":"70ae14df9b4a475786397f7bafda0e5d"},"installation":{"command":"CP040782.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWBXQ and MB008000GWBYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5387816","datemodified":"2020-12-13T09:03:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/CP045400.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/SVKBPND4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045400.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045400.scexe"],"md5sum":"58f29a833b5987d45d2bacbd9de34c21","name":"firmware-hdd-8c4a212ff9-HPD4-8.1.x86_64.rpm","release":"2020-12-13T08:47:09","revision":"0","sha1sum":"7a988a0b5af10639cad91579ca249caa42982ceb","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"62bd64385d4642c4adfd6fdae64666cb","version":"0683aef5c11449afae870d205a7ef13c"},"installation":{"command":"CP040263.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5364739","datemodified":"2020-11-25T11:31:07","file_list":["/CP044763_BUILD_12.data","/CP044763.vmexe","/CP044763.vmexe64","/CP044763.vmfile","/CP044763_VMw.zip","/CP044763.xml","/payload.json","/CP044763_VMw.zip/index.xml","/CP044763_VMw.zip/vendor-index.xml","/CP044763_VMw.zip/metadata.zip","/CP044763_VMw.zip/vib20/CP044763/HPE_bootbank_CP044763_2021.02.01.12-6.7.0.7535516.vib","/CP044763_VMw.zip/metadata.zip/vendor-index.xml","/CP044763_VMw.zip/metadata.zip/vmware.xml","/CP044763_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044763_2021.02.01.12-6.7.0.7535516.xml","/CP044763_VMw.zip/metadata.zip/vibs/CP044763-2743276029065597023.xml"],"md5sum":"863c9c0d24683a394cebc0a22600f0b2","name":"CP044763.zip","release":"2020-11-25T11:27:05","revision":"0","sha1sum":"b4ca0594cf6bb0f5bf93612b034dbe0c633f4438","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044763","version":"2021.02.01.12-6.7.0.7535516"}]}],"id":{"product":"ab64ba8d4a0a499eb17eec922888ce81","version":"2fa4ac2129944adba756c9356bf562a7"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-02T10:00:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE LPe1205A 8Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>12.60a4</td>\n\t\t\t<td>2.10X6</td>\n\t\t\t<td>12.6.284.0</td>\n\t\t\t<td>12.6.302.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.12</td>\n\t\t\t<td>12.6.275.7</td>\n\t\t\t<td>12.6.271.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3184264","datemodified":"2020-12-11T11:21:01","file_list":["cp046322.xml","cpqsetup.exe","GPM1645ASAD4.rel","payload.json","setup.dll"],"md5sum":"654deef3d6b005a2d50da233650b4c1a","name":"cp046322.exe","release":"2020-12-11T11:10:09","revision":"0","sha1sum":"5f84b1301d3a1cd231f3a35f53e24efb50912428","size":"3MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"38d3787c49804ab1b404f61b3cd58354","version":"23cb86b15d95410fbc5c16274dca809c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T19:25:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN, and VK001920KWDUH Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online NVMe SSD Flash Component for Windows (x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>     Added support for Windows 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>   </strong>  None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"6210760","datemodified":"2021-01-25T05:46:36","file_list":["cp045559.xml","cpqsetup.exe","payload.json","setup.dll","spannsK4.rel"],"md5sum":"633fb4cab93d3784df23949de5a0b7f7","name":"cp045559.exe","release":"2021-01-25T05:37:04","revision":"0","sha1sum":"9193c34fd39c807d5d1a5584d8d2b9cbc9716941","size":"5MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d06d054af702418fa905eb8595ceb958","version":"c86040f9b0934830a295239e4468dee5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:53:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL, and EG0900FCSPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4726260","datemodified":"2020-12-13T08:35:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/CP045382.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/TA13SED2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045382.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045382.scexe"],"md5sum":"8498b07d4e4875fc5af1cfba8b7c5e7e","name":"firmware-hdd-7c1a1734f9-HPD2-7.1.x86_64.rpm","release":"2020-12-13T08:23:09","revision":"0","sha1sum":"f6eda172cf898457b9e33840e916454e26de062d","size":"4MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"a3c9b8269658446e8b8ae9264c4873c2","version":"8184e201d6984d0c84f86f55dd46122b"},"installation":{"command":"CP040300.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:35:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-364875f2e83b","Version":"4H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-324808558bd9","Version":"4H3Q"},{"DeviceName":"MZPLJ6T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448edb4b867","Version":"4H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version is now available from the following OS-specific URLs: VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2 Linux: EPK74H3Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp; </strong>4H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"7557616","datemodified":"2021-01-23T12:02:13","file_list":["cp046695.xml","cpqsetup.exe","EPK74H3Q.rel","payload.json","setup.dll"],"md5sum":"796da398ad14ac28d5439a8a81271e66","name":"cp046695.exe","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"7a658bbddce2b2f9565b61c50aacbde2161f882f","size":"7MB","target_guids":["4d2340a5-505a-4a4c-3154-364875f2e83b","4d2340a5-505a-4a4c-3354-324808558bd9","4d2340a5-505a-4a4c-3654-3448edb4b867"],"type_of_change":"1","version":"4H3Q"}],"id":{"product":"99c23ff7c8d6427fabec401028b615d8","version":"c58f209c49b844c0be5f2a2c2c407db9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for Windows (x64) - MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:10:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">*REMOVED* - Version 4H3Q(B) is NO LONGER AVAILABLE for download. Working version EPK74H3Q supporting full firmware version&nbsp; is now available from the following OS-specific URLs:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">VMware: EPK74H3Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-51e52e05d02c4fdc8de04369ac</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Windows: EPK74H3Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-17f6773477584f40934ba719f2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Linux: EPK74H3Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-956b407dbe4a42fc97c065e86a</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Version EPK74H3Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000, MZPLJ3T2HBJR-000 and MZPLJ6T4HALA-000</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Working version EPK74H3Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD2"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16103587","datemodified":"2021-01-28T20:22:15","file_list":["/CP045723_BUILD_6.data","/CP045723.vmexe","/CP045723.vmexe64","/CP045723.vmfile","/CP045723_VMw.zip","/CP045723.xml","/payload.json","/CP045723_VMw.zip/index.xml","/CP045723_VMw.zip/vendor-index.xml","/CP045723_VMw.zip/metadata.zip","/CP045723_VMw.zip/vib20/CP045723/HPE_bootbank_CP045723_HPD2.6-7.0.0.15843807.vib","/CP045723_VMw.zip/metadata.zip/vendor-index.xml","/CP045723_VMw.zip/metadata.zip/vmware.xml","/CP045723_VMw.zip/metadata.zip/vibs/CP045723--3110200918899455669.xml","/CP045723_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045723_HPD2.6-7.0.0.15843807.xml"],"md5sum":"fddd1241bff64d5dc311a48e33a0ec9c","name":"CP045723.zip","release":"2021-01-28T20:19:04","revision":"0","sha1sum":"8fa1d4d441567f49149937e9f3805bdd1624d777","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045723","version":"HPD2.6-7.0.0.15843807"}]}],"id":{"product":"d1014161143144dea5631e9b65f9f0d4","version":"4acb8f33ebca432bae23182e83d7c4a0"},"installation":{"command":"CP041560.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:51:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;4ICDHPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16321916","datemodified":"2021-01-28T21:18:56","file_list":["/CP046728_BUILD_2.data","/CP046728.vmexe","/CP046728.vmexe64","/CP046728.vmfile","/CP046728_VMw.zip","/CP046728.xml","/payload.json","/CP046728_VMw.zip/index.xml","/CP046728_VMw.zip/vendor-index.xml","/CP046728_VMw.zip/metadata.zip","/CP046728_VMw.zip/vib20/CP046728/HPE_bootbank_CP046728_4ICDHPK1.2-7.0.0.15843807.vib","/CP046728_VMw.zip/metadata.zip/vendor-index.xml","/CP046728_VMw.zip/metadata.zip/vmware.xml","/CP046728_VMw.zip/metadata.zip/vibs/CP046728--8872019671510386649.xml","/CP046728_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046728_4ICDHPK1.2-7.0.0.15843807.xml"],"md5sum":"e4dc7bdb05f1bb43efd45976feed74e0","name":"CP046728.zip","release":"2021-01-28T21:16:08","revision":"0","sha1sum":"1f6557b7e4d6810d5edd304133e258be7c9a950a","size":"15MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"1","version":"4ICDHPK1","vib_list":[{"name":"CP046728","version":"4ICDHPK1.2-7.0.0.15843807"}]}],"id":{"product":"180a7c20ed0347b4a9c066f5e5cf116b","version":"e7ccf3b882044005b622e0a6d281e6cf"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SDD Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-28T09:09:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Agentless Management Smart Component for ESXi 7.0 includes the latest HPE Agentless Management Service (AMS), and AMS ESXCLI Interface."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"713100","datemodified":"2021-02-26T14:58:41","file_list":["/cp046906.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip","/amsdComponent_701.11.7.1.3-1_17671487.zip/index.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip/vendor-index.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip/metadata.zip","/amsdComponent_701.11.7.1.3-1_17671487.zip/vib20/amsd/HPE_bootbank_amsd_701.11.7.1.3-1OEM.701.0.0.16555998.vib","/amsdComponent_701.11.7.1.3-1_17671487.zip/metadata.zip/vendor-index.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip/metadata.zip/vmware.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip/metadata.zip/vibs/amsd--2484965393930030223.xml","/amsdComponent_701.11.7.1.3-1_17671487.zip/metadata.zip/bulletins/amsdComponent_701.11.7.1.3-1.xml"],"md5sum":"c0d0575d11011f9931c34a33b2528ce1","name":"cp046906.zip","release":"2021-02-26T14:57:03","revision":"0","sha1sum":"33a5b6763e3c6e15cdb9442b706dc7da6f8652a5","size":"696KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"type_of_change":"1","version":"2021.04.12","vib_list":[{"name":"amsd","version":"701.11.7.1.3-1OEM.701.0.0.16555998"}]}],"id":{"product":"5588a72e9c0d4878a499b54f0c18241c","version":"a7af1b9901e64e399d5e5fdd3aebc794"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (HPSUM) from the HPE Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Agentless Management Bundle Smart Component on ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-12T02:34:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix PSOD exception resulting from repeated failed attempts to communicate to iLO</li>\n\t<li>Fix false NVMe disk temperature alerts</li>\n\t<li>Fix missing OS, driver and software info from AHS logs</li>\n\t<li>Fix max and threshold temperature values for SATA disks to prevent fans from running at higher rate</li>\n\t<li>Fix false SATA disk status change alerts</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Reduce Software Inventory cache refresh time&nbsp;to 15 seconds to help resolve OneView online SW update issues without reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"amsdComponent:701.11.7.1.3-1","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE Agentless Management Service (hp-ams) provides support for HPE Integrated Lights-Out 4 (HPE iLO 4) Embedded Health and Alerting."},{"lang":"ja","x_late":"HPE Agentless Management Service（hp-ams）は、HPE Integrated Lights Out 4（HPE iLO 4）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Diagnosing connection issues:</strong></p>\n\n<p>Verify that the HPE iLO 4 is talking to SNMP from a Linux system with net-snmp utilities installed:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>Verify that HPE AMS is operating on the Server:</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong>&nbsp;<em>1.3.6.1.4.1.232.5.1</em></p>\n"},{"lang":"ja","x_late":"<p><strong>接続の問題の診断：</strong></p>\n\n<p>HPE iLO 4が、net-snmpユーティリティがインストールされたLinuxシステムから、SNMPに通信していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.1.1</em></p>\n\n<p>サーバー上でHPE AMSが動作していることを確認：</p>\n\n<p style=\"margin-left:40px\"><em>snmpwalk -t 60 -v 2c -Ox -c</em> <strong>iLO4_configured_community_string</strong> <strong>iLO4_IP_Address</strong> <em>1.3.6.1.4.1.232.5.1</em></p>\n"}],"files":[{"bytes":"792587","datemodified":"2021-03-22T16:01:20","file_list":["./etc/sysconfig/hp-ams","./opt/hp/hp-ams","./opt/hp/hp-ams/hp-ams.license","./sbin/amsHelper","./usr/lib/.build-id","./usr/lib/.build-id/27","./usr/lib/.build-id/27/0dd823ef9a3078e58e91e472118e192353b431","./usr/lib/systemd/system/hp-ams.service","./usr/share/man/man8/amsHelper.8.gz","./usr/share/smartupdate/hp-ams/component.xml"],"md5sum":"9885892a4b92121be45df4c2f9734534","name":"hp-ams-2.10.2-876.6.rhel8.x86_64.rpm","release":"2021-03-22T15:51:16","revision":"0","sha1sum":"600f71aa12f70cd9d3025df3ac6e86b1e98a0f22","size":"774KB","target_guids":[],"type_of_change":"0","version":"2.10.2"}],"id":{"product":"ff838e600d484f85bc0967ebce9789c9","version":"dd3b0d928e6d4907a41be8a294bc250b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"","SubRequirements":[]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>To install the package type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm -ivh hp-ams-&lt;version&gt;.rpm</p>\n\n<p>To check whether the package is loaded properly type:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;systemctl status hp-ams</p>\n\n<p>Additional help is available by typing:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;man amshelper</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Agentless Management Service for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-07T12:15:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the Following Items:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added&nbsp;the warning message for users to restart hp-ams service when iLo reset more than twice. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099805en_us\" style=\"color:#0563c1; text-decoration:underline\">a00099805en_us</a>.&nbsp;&nbsp;</li>\n\t<li>When the server detects the physical network cable is plugged or unplugged, hp-ams will send out a trap to notify the administrator about the&nbsp;physical network status change.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed&nbsp;a small amount of memory leak as documented in the Customer Advisory, <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\" style=\"color:#0563c1; text-decoration:underline\">a00053824en_us</a></li>\n\t<li>&nbsp;NVMe drive information is now available in the CPQSE.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"hp-ams","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p><strong>Known Issues(refer to Customer Bulletin for workarounds):</strong></p>\n\n<ul>\n\t<li>None.</li>\n</ul>\n"}],"files":[{"bytes":"7194328","datemodified":"2021-01-21T19:05:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/CP046661.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/GP1723b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046661.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046661.scexe"],"md5sum":"89a6de0670c8423f17d056f6fcc77f72","name":"firmware-hdd-fe9c474847-HPK3-1.1.x86_64.rpm","release":"2021-01-21T18:46:06","revision":"0","sha1sum":"407ad8d87d92a106d8e108ce9facc10b5c041050","size":"6MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"5bfad4d210f242bd90a5c8fa29d29f05","version":"015f4c322a164e6494c7e3ffb7fdf9e9"},"installation":{"command":"CP041314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T18:41:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue where the SSID was not programmed correctly to the drive. This may cause issues with the drive not being identified correctly in the Integrated Lights Out Utility.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Dual 8GB microSD Enterprise Midline USB"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPEデュアル 8GB MicroSD Enterprise Midline USBのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online Smart Component which upgrades firmware on HPE Dual 8GB&nbsp;microSD Enterprise Midline USB&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.215<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.215<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.3.2.212<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None.</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     HPE Dual 8GB microSD Enterprise Midline USB上のファームウェアをアップグレードするオンラインSmartコンポーネント </p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.3.2.215<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.3.2.215<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.3.2.212<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし</p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>\n\t<p>なし。</p>\n\t</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>Agentless Management Serviceバージョン11.2.0以降で対応するHPEデュアル8GBミクロンSDの製品番号を表示する。</li>\n</ul>\n\n<p><strong>既知の問題点：</strong> <br />\n     なし</p>\n"}],"files":[{"bytes":"1059079","datemodified":"2018-11-13T03:09:46","file_list":["/CP037940.vmexe","/CP037940.vmfile","/CP037940.xml","/README.txt"],"md5sum":"72e5ac789c296b7a5ca15ba8551f6786","name":"CP037940.zip","release":"2018-11-13T08:56:03","revision":"0","sha1sum":"c5eb9ce02c807748bfee8e39386acd16823a5515","size":"1MB","target_guids":[],"type_of_change":"1","version":"1.3.2.215","vib_list":[]}],"id":{"product":"afd60bda7b524c9d827bf70af6eb6201","version":"f556c312fdc24859bf6fde57b13db68f"},"installation":{"command":"CP037940.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p style=\"margin-left: 40px;\"><strong>Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"text-decoration: none; color: blue;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HP Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HP Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong></p>\n\n<p style=\"margin-left: 40px;\"><strong>リモートオンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"text-decoration: none; color: blue;\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash component for VMware ESXi - HPE Dual 8GB microSD USB"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPEデュアル 8GB MicroSD USB"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-22T08:39:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>To show corresponding&nbsp;HPE Dual 8GB&nbsp;Micron SD&nbsp;&nbsp;part number&nbsp;in Agentless Management Service version 11.2.0 or later.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"}],"sw_keys":[{"name":"HPE Dual 8GB microSD USB","sw_key_expectedpath":"firmware:sd:microsdusb"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"此智能组件为HPE Apollo 45xx Gen9背板扩展卡提供固件"},{"lang":"tw","x_late":"此智慧型元件提供適用於 HPE Apollo 45xx Gen9 背板擴充卡的韌體"},{"lang":"ko","x_late":"이 스마트 구성요소가 HPE Apollo 45xx Gen9 백플레인 익스팬더의 펌웨어 제공"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen9バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 2.08<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.50<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Expander may reset during heavy SSACLI polling</li>\n\t<li>SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3653632","datemodified":"2018-11-01T05:06:30","file_list":["cp038040.xml","cpqsetup.exe","firmware-Release-2.50-build-000.bin.fw","setup.dll"],"md5sum":"8d84f711e3847f83e548192d03e26239","name":"cp038040.exe","release":"2018-11-01T09:57:33","revision":"0","sha1sum":"f999b30cf93266aaa288312a2ed203b74c96c3ff","size":"3MB","target_guids":[],"type_of_change":"0","version":"2.50"}],"id":{"product":"438f20c90cc14939afac73df8f31d682","version":"abe1e113798b42019c64b9f4507c60e8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>バージョン1.03以前からのファームウェアアップグレードを有効にするために、サーバーの電源コードを1度抜いて、再度挿してください。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、\n          </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant:</a>から以下の手順に従ってください</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 45xx Gen9 Backplane Expander Firmware "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 45xx Gen9バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-12-01T09:24:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>&nbsp;Expander may reset during heavy SSACLI polling</li>\n\t<li>SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11381224","datemodified":"2021-01-27T22:47:58","file_list":["cp046690.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_2.42_01_23_2021.signed.flash"],"md5sum":"e38f44f7229b913c96f0aeeee348b1de","name":"cp046690.exe","release":"2021-01-27T22:46:04","revision":"0","sha1sum":"b3b9135c42dde740a62b1e6002045e9d9c8a7c4c","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"1bc921f76f2d48759522424a4aff4914","version":"a78c5b2adc924114bfb01d4b4ebe1728"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T22:17:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Added a new BIOS/Platform Configuration (RBSU) option to Advanced PCIe Device Configuration called PCIe Switch MMIO Configuration.  This option addresses a virtualization issue caused by different interpretations of the PCIe specification by disabling PCIE Switch MMIO Configuration.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE 100Gb 1p OPA 860z FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F01590021C","Version":"1.9.200"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E8","Version":"1.9.200"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E7","Version":"1.9.200"},{"DeviceName":"Intel Corporation Omni-Path HFI Silicon 100 Series [discrete]","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.9.2.0.0.rom","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0808624F0","Version":"1.9.200"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Intel OPA firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE Intel OPAファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"background-color:#f5f5f5; color:#000000; font-family:verdana,helvetica,sans-serif; font-size:11px; height:94px; width:821px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\"><strong>OPA HFI Adapter Type</strong></td>\n\t\t\t<td style=\"text-align:center\"><strong>Firmware Version</strong></td>\n\t\t\t<td style=\"text-align:center\"><strong>SSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">E7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter&nbsp;</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">E8</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"text-align:center\">HPE Apollo 100Gb 1-port Intel Omni-Path Architecture 860z Mezzanine FIO Adapter</td>\n\t\t\t<td style=\"text-align:center\">1.9.2.0.0</td>\n\t\t\t<td style=\"text-align:center\">21C</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"261098","datemodified":"2019-05-29T01:30:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/CP039790.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/CP039790.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/HfiPcieGen3Loader_1.9.2.0.0.rom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/HfiPcieGen3_1.9.2.0.0.efi","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/nic_fw/hfi1_eprom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.9.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP039790.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP039790.scexe"],"md5sum":"dbb5dda7ea0cf9a331fa54825f93339c","name":"firmware-nic-intel-opa-hfi-1.9.2-1.1.x86_64.rpm","release":"2019-05-29T06:31:08","revision":"0","sha1sum":"13d330be8564fc797e0d960310e24beb0746d090","size":"254KB","target_guids":["a6b1a447-382a-5a4f-8086-24F01590021C","a6b1a447-382a-5a4f-8086-24F0159000E8","a6b1a447-382a-5a4f-8086-24F0159000E7","a6b1a447-382a-5a4f-8086-24F0808624F0"],"type_of_change":"1","version":"1.9.2"}],"id":{"product":"7943f29050984f1f850b2530e1fd78f4","version":"91282beb581841a9a0428991925b27bd"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Intel OPA adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"24F0","subdev":"021C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f01590021c","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"00E8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e8","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"00E7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e7","type":"pci","ven":"8086"},{"dev":"24f0","subdev":"24f0","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-24f0808624f0","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-06-08T09:56:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 1.8.1.0.0 :</strong></p>\n\n<ul>\n\t<li>Added hfi1_eprom <strong>v10_8_0_0_13.</strong></li>\n\t<li>Loader ROM <strong>HfiPcieGen3Loader_1.8.1.0.0.rom</strong> and driver EFI <strong>HfiPcieGen3_1.8.1.0.0.efi</strong> were added.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 1.9.2:</strong></p>\n\n<ul>\n\t<li>Added hfi1_eprom <strong>v10_9_2_0_0.</strong></li>\n\t<li>Loader ROM <strong>HfiPcieGen3Loader_1.9.2.0.0.rom</strong> and driver EFI <strong>HfiPcieGen3_1.9.2.0.0.efi </strong>were added.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been resolved in version 1.9.2:</strong></p>\n\n<ul>\n\t<li>Due to a SLES 15 kernel setting, hfi1_eprom cannot work while the HFI driver is loaded. The tool and driver are mutually exclusive.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"Intel_OPA_HFI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4170147","datemodified":"2021-01-21T06:41:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/CP045970.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045970.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045970.scexe"],"md5sum":"539b35f5bf74080bb05e17098adf836c","name":"firmware-d6020-2.74-9.1.x86_64.rpm","release":"2021-01-21T06:28:07","revision":"0","sha1sum":"0648ea723f544eccffd645c982ecf22095958386","size":"3MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"id":{"product":"ce7e63b5ed004965a0bc6af06ca584ef","version":"0f7a7e3bb5e64b3a8635fde80674ce96"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e,&nbsp;--reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f,&nbsp; --force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g,&nbsp;--downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s,&nbsp;--silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-29T05:15:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v183133/D6020_P07232-008.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.1002"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20881960","datemodified":"2021-01-22T12:46:36","file_list":["cp045148.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_1002-825110-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","fw-ConnectX4-rel-12_28_1002-825111-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","fw-ConnectX5-rel-16_29_1016-872726-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","fw-ConnectX5-rel-16_29_1016-879482-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"6f52fd0ca9ff0009359b72d35f7796cf","name":"cp045148.exe","release":"2021-01-22T12:45:08","revision":"0","sha1sum":"7949e5ce1297d598a70c289d1ca841b32cb238f0","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.0.9"}],"id":{"product":"cdfe3840d6074900a4d11b774d3e5307","version":"d022fc5463dd43e18df5b0dc7bf21e48"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade/downgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (and earlier) to 16.26.1xxx (and later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 7.0."},{"lang":"ja","x_late":"このパッケージには、ESXi 7.0上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート548SFP+アダプター（P11338-B21）</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"16651717","datemodified":"2021-02-03T07:22:32","file_list":["/CP045199.vmexe64","/CP045199.vmfile","/CP045199_VMw.zip","/CP045199.xml","/payload.json","/README.txt","/CP045199_VMw.zip/index.xml","/CP045199_VMw.zip/vendor-index.xml","/CP045199_VMw.zip/metadata.zip","/CP045199_VMw.zip/vib20/CP045199/HPE_bootbank_CP045199_1.0.0-7.0.0.15525992.vib","/CP045199_VMw.zip/metadata.zip/vendor-index.xml","/CP045199_VMw.zip/metadata.zip/vmware.xml","/CP045199_VMw.zip/metadata.zip/vibs/CP045199--1427702349404464808.xml","/CP045199_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045199_1.0.0-7.0.0.15525992.xml"],"md5sum":"a60c68177d026a499df5a69e6bb81450","name":"CP045199.zip","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"9c9b87451b237cf1de3d572189ac83ee391c95e9","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045199","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"d9e21a24798447d3b9521f317ae3815c","version":"cdd64a1a36074a01a96d78668a6be53d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 7.0）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T20:24:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.28.1002:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.28.1002:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG1"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG1"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG1"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"24902405","datemodified":"2021-01-28T15:49:55","file_list":["/CP045697_BUILD_6.data","/CP045697.vmexe","/CP045697.vmexe64","/CP045697.vmfile","/CP045697_VMw.zip","/CP045697.xml","/payload.json","/CP045697_VMw.zip/index.xml","/CP045697_VMw.zip/vendor-index.xml","/CP045697_VMw.zip/metadata.zip","/CP045697_VMw.zip/vib20/CP045697/HPE_bootbank_CP045697_HPG1.6-7.0.0.15843807.vib","/CP045697_VMw.zip/metadata.zip/vendor-index.xml","/CP045697_VMw.zip/metadata.zip/vmware.xml","/CP045697_VMw.zip/metadata.zip/vibs/CP045697--440140270280111667.xml","/CP045697_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045697_HPG1.6-7.0.0.15843807.xml"],"md5sum":"f0288ff4f8eafc3edfea064907e153da","name":"CP045697.zip","release":"2021-01-28T15:47:05","revision":"0","sha1sum":"c0701faa677afdb0315aff686509d12f10386e35","size":"23MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045697","version":"HPG1.6-7.0.0.15843807"}]}],"id":{"product":"a6c377914cad4568810f0a24fc0faa52","version":"4db1b4e31bf84d5d857f1e7d26a1800d"},"installation":{"command":"CP043281.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:31:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"0.37"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.37.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"0.37"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 4200&nbsp;Gen10+ Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;0.37<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Initial Release</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16898446","datemodified":"2021-01-27T14:17:59","file_list":["/CP044965_BUILD_8.data","/CP044965.vmexe","/CP044965.vmexe64","/CP044965.vmfile","/CP044965_VMw.zip","/CP044965.xml","/payload.json","/CP044965_VMw.zip/index.xml","/CP044965_VMw.zip/vendor-index.xml","/CP044965_VMw.zip/metadata.zip","/CP044965_VMw.zip/vib20/CP044965/HPE_bootbank_CP044965_0.37.8-7.0.0.15843807.vib","/CP044965_VMw.zip/metadata.zip/vendor-index.xml","/CP044965_VMw.zip/metadata.zip/vmware.xml","/CP044965_VMw.zip/metadata.zip/vibs/CP044965--7110690839688510648.xml","/CP044965_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044965_0.37.8-7.0.0.15843807.xml"],"md5sum":"8ae54e3042fb36c806c2312435e35c99","name":"CP044965.zip","release":"2021-01-27T14:03:04","revision":"0","sha1sum":"1068d98e6cff31fdf04ac08412960efab5a8b340","size":"16MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"0.37","vib_list":[{"name":"CP044965","version":"0.37.8-7.0.0.15843807"}]}],"id":{"product":"a271f679286141d98830336f93a8205f","version":"1810fdb1a687491283b9e3fed3d58441"},"installation":{"command":"CP044965.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HP Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, for the firmware update to take effect</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10+ Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T16:05:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4925420","datemodified":"2021-01-28T23:49:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/4ICDHPK1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/CP046732.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046732.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046732.scexe"],"md5sum":"8abc02dd1c7757d19c6ba8ebcc0cf5c4","name":"firmware-hdd-1656c1b14a-4ICDHPK1-1.1.x86_64.rpm","release":"2021-01-28T23:31:04","revision":"0","sha1sum":"7a02c8e49d225a29bbdf456ff4786f1c3467b916","size":"4MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"288dbea3acd4439082f94ee3a892bf62","version":"783ff59130864967a7428fb21e6714e5"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-28T23:04:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000300JWFVB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWFVB&nbsp;Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4855427","datemodified":"2020-12-13T08:07:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/CP045375.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/T14SErD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045375.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045375.scexe"],"md5sum":"41d5f4ee8e72e7836e6755ad5ddfb7a8","name":"firmware-hdd-c5cd837c29-HPD2-6.1.x86_64.rpm","release":"2020-12-13T07:55:07","revision":"0","sha1sum":"5a2696b35d628927f7320a5f4709435b9a05cdcd","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"0","version":"HPD2"}],"id":{"product":"7163f5a35db04c1899f77a9e771fd83e","version":"9fbdcbe24455465ea956fcb0bf28022a"},"installation":{"command":"CP040323.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWFVB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:27:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive model: MB014000GWUDA drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB014000GWUDAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18852563","datemodified":"2021-01-27T16:11:51","file_list":["/CP045645_BUILD_3.data","/CP045645.vmexe","/CP045645.vmexe64","/CP045645.vmfile","/CP045645_VMw.zip","/CP045645.xml","/payload.json","/CP045645_VMw.zip/index.xml","/CP045645_VMw.zip/vendor-index.xml","/CP045645_VMw.zip/metadata.zip","/CP045645_VMw.zip/vib20/CP045645/HPE_bootbank_CP045645_HPG2.3-7.0.0.15843807.vib","/CP045645_VMw.zip/metadata.zip/vendor-index.xml","/CP045645_VMw.zip/metadata.zip/vmware.xml","/CP045645_VMw.zip/metadata.zip/vibs/CP045645--4485279102655689514.xml","/CP045645_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045645_HPG2.3-7.0.0.15843807.xml"],"md5sum":"49e0b6ff13fe4330d4302a91fd6273a8","name":"CP045645.zip","release":"2021-01-27T16:09:04","revision":"0","sha1sum":"28488390a755940e8c771e3eb71518aef08e8e32","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045645","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"eaadba373a2b4b7ab82c00e6e1f55628","version":"ea40446a60ef49ce9c26ee757ad061b5"},"installation":{"command":"CP041507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:45:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"121620","datemodified":"2021-01-08T22:09:29","file_list":["/cp045339.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.700.1.0.15843807.vib","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vibs/igbn-2757282774975846762.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807.xml"],"md5sum":"a882ada8e8ff1470d08ffc60d66dbb88","name":"cp045339.zip","release":"2021-01-08T22:08:04","revision":"0","sha1sum":"912a935772bcf33e025218354966f9c5a2e5e17a","size":"118KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d6816ab14fc34e169d27b5a4d2e7e7a1","version":"894f7e0469fc41eab85e1b46dab97fa4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048992af248","Version":"3H5Q"},{"DeviceName":"MZXL51T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-364889da9feb","Version":"3H5Q"},{"DeviceName":"MZXL53T2HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-3248cfd7fef8","Version":"3H5Q"},{"DeviceName":"MZXL56T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-3448c531f122","Version":"3H5Q"},{"DeviceName":"MZXL512THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-54488858a5c5","Version":"3H5Q"},{"DeviceName":"MZXL5960HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-3048d9dd07de","Version":"3H5Q"},{"DeviceName":"MZXL51T9HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-39483a8fb090","Version":"3H5Q"},{"DeviceName":"MZXL53T8HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38488ed832eb","Version":"3H5Q"},{"DeviceName":"MZXL57T6HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-36489d1db6a9","Version":"3H5Q"},{"DeviceName":"MZXL515THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-544832bf723c","Version":"3H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs: VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07 Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37 Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000, MZXL515THALA-000 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp; </strong>3H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"9500403","datemodified":"2021-01-23T12:13:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/CP046679.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/MPK73H5Q.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-3H5Q-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046679.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046679.scexe"],"md5sum":"921239a96e6d9762dae18b6145766b75","name":"firmware-hdd-e320db791d-3H5Q-2.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"2166e1c8189e88b69d442fbeda3300f9d7bcb8d1","size":"9MB","target_guids":["4d2340a5-585a-354c-3830-3048992af248","4d2340a5-585a-354c-3154-364889da9feb","4d2340a5-585a-354c-3354-3248cfd7fef8","4d2340a5-585a-354c-3654-3448c531f122","4d2340a5-585a-354c-3132-54488858a5c5","4d2340a5-585a-354c-3936-3048d9dd07de","4d2340a5-585a-354c-3154-39483a8fb090","4d2340a5-585a-354c-3354-38488ed832eb","4d2340a5-585a-354c-3754-36489d1db6a9","4d2340a5-585a-354c-3135-544832bf723c"],"type_of_change":"1","version":"3H5Q"}],"id":{"product":"5b139cd72d0b4c89818f276c3a1dce8c","version":"834a4df7aca24c9faaa9c77ab455c9b3"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-00 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T05:54:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Working version MPK73H5Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL53T2HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL512THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 Red Hat Enterprise Linux 7 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 5 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"118472","datemodified":"2021-01-17T07:09:51","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"2e577aa848e57982fa2a1cc9fba319e1","name":"kmod-tg3-3.139b-1.rhel7u8.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"9ffb3913d1b2bde21868351d38269c6db68d30d5","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"118475","datemodified":"2021-01-17T07:07:50","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"6b00b8e8dc8a92bfba2faae68af7d6ef","name":"kmod-tg3-3.139b-1.rhel7u9.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"233f44987be805e24559a094415ff1256682977f","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"f4e486fae98c4ecea1e8d2f80f412bb9","version":"bf80ddf91812427facda6e8e5dfdcc45"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 5 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 update 9</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;&nbsp;VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4747525","datemodified":"2020-12-13T15:49:46","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/CP045465.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/GPM853G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045465.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045465.scexe"],"md5sum":"22aa030791cb96f259a273e2a3cc3835","name":"firmware-hdd-1a516522d1-HPG1-8.1.x86_64.rpm","release":"2020-12-13T15:38:15","revision":"0","sha1sum":"89c0b0808b10b78654b5520616022d4287cd6587","size":"4MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"86fd494457ed46feb0f879467158193c","version":"29f14f28e3cd49e48ad5f77fa73883c0"},"installation":{"command":"CP040297.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5977992","datemodified":"2020-10-28T21:26:08","file_list":["I36_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046087.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"600fc418b3d8e5f2a36766623a34cfbe","name":"cp046087.exe","release":"2020-10-28T21:09:05","revision":"0","sha1sum":"a03b24c0ea1e1b4eba2cf727ec605529f53131f2","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"05ff557836a74529980644359cf7e2c2","version":"8c4ac2e12a1c44e1887f4676d89bbac0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant BL460c Gen9/WS460c Gen9 (I36)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:09:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled (TXT is disabled by default). This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"I36","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1928736","datemodified":"2021-02-09T08:01:27","file_list":["cp043869.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"cf217ed1e6734d44526968d2ff48c2de","name":"cp043869.exe","release":"2021-02-09T07:47:05","revision":"0","sha1sum":"1fbb00b9eade2c29217a59e7d4e438875d5ab232","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"19810cc433a442df903276a4b0c34598","version":"3269916fcbf34d988e11d77cbd9f82c6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox CX5 and CX6DX Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30117","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30040","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30042","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30102","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30047","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30116","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30052","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"186366","datemodified":"2021-01-19T03:05:50","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"b87a94d6c14904ae2709dea9694a5a53","name":"kmod-hp-ixgbe-5.9.4-1.rhel8u2.x86_64.rpm","release":"2021-01-19T02:59:05","revision":"0","sha1sum":"b6cfe7591e0ada35e772941cd24bceb9a8860d80","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"186467","datemodified":"2021-01-19T03:09:07","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"252c9b6cd85e10ab8ab286a442a81bad","name":"kmod-hp-ixgbe-5.9.4-1.rhel8u3.x86_64.rpm","release":"2021-01-19T02:59:05","revision":"0","sha1sum":"51e8816746d513a8b0df0f5abef64df35185be2c","size":"182KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"760adb908c054b5b910c54e6c4a5f9e4","version":"0a720e62376e46e3be17948808b902ba"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新電源管理控制器韌體。 "},{"lang":"en","x_late":"This component updates the Power Management Controller firmware. "},{"lang":"ko","x_late":"이 구성 요소는 전원 관리 컨트롤러 펌웨어를 업데이트합니다. "},{"lang":"cn","x_late":"该组件更新电源管理控制器固件。 "},{"lang":"ja","x_late":"このコンポーネントは、Power Management Controllerファームウェアをアップデートします。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"625984","datemodified":"2018-10-08T15:37:53","file_list":["amd64/","amd64/CpqCi.dll","amd64/CpqCi32.dll","amd64/cpqcidrv.cat","amd64/CpqCiDrv.inf","amd64/CpqCiDrv.sys","amd64/cpqsmif.dll","amd64/cpqsmif32.dll","amd64/drvinst.exe","cp037764.xml","cpqsetup.exe","cpqsysio64.sys","firmware.ini","PowerPicInstaller64.dll","SNARFR41.hex"],"md5sum":"6d9b73c0788acf505ceab3cb16d05f38","name":"cp037764.exe","release":"2018-10-08T20:37:06","revision":"0","sha1sum":"59ce1766d4c7b21fc4292eb279299ca48daa1a08","size":"611KB","target_guids":[],"type_of_change":"1","version":"4.1"}],"id":{"product":"5e40c73cb84f441f80acf9f709720859","version":"dd821dd7504540a78e4228ce17f5730d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">To update firmware from Windows operating system on target server:</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired components&nbsp;to be updated in the directory, \\packages on the USB key. To use with SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This component can only be executed on Windows x64.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Power Management Controller for HPE ProLiant DL580 Gen9/Gen8 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"5","minor":"2","name":"Microsoft Windows HPC Server 2008","platform":"NT","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T15:03:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (E) contains an update to resolve information disclosure vulnerability issue ref: CVE-2017-8992.&nbsp; It is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;(E) if a previous component revision was used to upgrade the firmware to ver.4.1.</p>\n\n<p><strong><strong>Firmware Dependencies:</strong></strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.<br />\n&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver.&nbsp;4.1 (F) adds support to perform the Online ROM Flash with Microsoft Windows Server 2016 by using Smart Update Manager.&nbsp; It is functionally equivalent to ver. 4.1.&nbsp; It is not necessary to upgrade with Revision&nbsp;(F) if a previous component revision was used to upgrade the firmware to ver.4.1.</p>\n\n<p><strong><strong>Firmware Dependencies:</strong></strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong><strong>Known Issues:</strong></strong></p>\n\n<p>The smart component prompts for reboot unnecessarily when the installation procedure is completed. Reboot is not required after installation for updates to take effect and hardware stability to be maintained.<br />\n&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"PowerPIC-DL580","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"981008","datemodified":"2021-02-09T07:35:58","file_list":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp045019.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"3a7f969f4518f9100a46b60b84c42f30","name":"cp045019.exe","release":"2021-02-09T07:22:05","revision":"0","sha1sum":"062c0484166e1e5297ed03643dbef691d6f1c0ea","size":"958KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"0","version":"214.0.0.6"}],"id":{"product":"b9a8e50fea15459f9f236f2538fb4a07","version":"6796559031774402b1116055f89cc4a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟和目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다."},{"lang":"cn","x_late":"将 Smart Component 下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击“安装”按钮进行安装。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1 1Gbドライバーfor Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which system crashed while enable/disable cycle when running along with certain video driver.</li>\n\t<li>This product correct an issue which the Gets statistics from a network adapter command (Get-NetAdapterStatistics) does not work with WS2019.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product correct an issue which fixes Windows driver causes NMI/RSOD during OS shutdown.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"b57nd60a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1108.0が含まれています。</p>\n"}],"files":[{"bytes":"3343325","datemodified":"2020-06-11T04:21:05","file_list":["/cp044543.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"69d45074ffc53654621999495e48e277","name":"cp044543.zip","release":"2020-06-11T04:20:05","revision":"0","sha1sum":"66e2c3ea4389eac2e20d962051e094899220d657","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"21671a6ff3c64fa1be71c992a0903728","version":"bafcd3494cbc44a3bf3b9aaa241ffacf"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.5.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD8"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3576304","datemodified":"2020-12-16T15:41:07","file_list":["cp045563.xml","cpqsetup.exe","payload.json","SAVNGSD8.rel","setup.dll"],"md5sum":"26e33d044bc4d16d0e24febf077b5361","name":"cp045563.exe","release":"2020-12-16T15:30:09","revision":"0","sha1sum":"ff68beb48c608e55fd0f882e0720259c4ac3c9af","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"0","version":"HPD8"}],"id":{"product":"182450d5bced417a85db3271254808a7","version":"63d5ef924fbb49bdb10d152007bf5f2d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:55:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0300JDYTH, EH0450JDYTK, and EH0600JDYTL drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0300JDYTH、 EH0450JDYTK、および EH0600JDYTL ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n"}],"files":[{"bytes":"5532061","datemodified":"2020-12-13T09:01:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/CP045399.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/HKFLRCD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045399.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045399.scexe"],"md5sum":"af2a3c5c61f2a729eadd256139bcc43f","name":"firmware-hdd-b9340d29be-HPD6-8.1.x86_64.rpm","release":"2020-12-13T08:47:05","revision":"0","sha1sum":"ab10d87fb2373ad5441c05dbf1096a33f18ed81c","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"ada4d6aedd4b4604b810f81be7da5b19","version":"8ea8b5ddbbed494483cd9c3862f9b640"},"installation":{"command":"CP040317.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8634023","datemodified":"2021-03-15T22:07:58","file_list":["/CP047161.vmexe","/CP047161.vmfile","/CP047161.xml","/README.txt"],"md5sum":"e6fc44da2c50e8aad19957e805360a22","name":"CP047161.zip","release":"2021-03-16T03:05:04","revision":"0","sha1sum":"01eff4bc2ccbe18d349c5811bb1ea232911c45a9","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"207e342b08574d3c81d084ed48dc2f05","version":"a582314c279949fe92a9b8ea5c502586"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE Apollo 4200 Gen9/HPE ProLiant XL420 Gen9 (U19)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T02:35:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"U19","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1967728","datemodified":"2020-12-09T13:15:19","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/vfio","./lib/modules/4.12.14-120-default/updates/drivers/vfio/mdev","./lib/modules/4.12.14-120-default/updates/drivers/vfio/mdev/i915.ko","./lib/modules/4.12.14-120-default/updates/drivers/vfio/mdev/kvmgt.ko","./lib/modules/4.12.14-120-default/updates/drivers/vfio/mdev/mdev.ko","./lib/modules/4.12.14-120-default/updates/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"d41cada9ef8c7f8eefc767652f5ea751","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.2.2.4.1.sles12sp5.x86_64.rpm","release":"2020-12-09T11:40:04","revision":"0","sha1sum":"ab0e8bf0b87dc3a06545b37294f89c985f74d98a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"1933428","datemodified":"2020-12-09T13:21:36","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"41878ee0753404a8d33599b23019ebdb","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles12sp5.x86_64.rpm","release":"2020-12-09T11:40:04","revision":"0","sha1sum":"b10d183bc17db300b0d18031e9124a0018e62ee7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"38f8dc6c0e3046598e2c4afc7a94419e","version":"0e42df4e314642128a17d2e2c13871ef"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles12sp5.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.2.2.4.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB1000GVYZE、MB2000GVYZF、MB3000GVYZHおよびMB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5260983","datemodified":"2020-12-13T13:21:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/CP045427.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/SMBPNTG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045427.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045427.scexe"],"md5sum":"762b4ea9014ccf4a8f21927ed8bdf953","name":"firmware-hdd-0a7010918e-HPG4-9.1.x86_64.rpm","release":"2020-12-13T13:10:04","revision":"0","sha1sum":"53f1b87a1044bd39a78a50c6e280ab1fbac5e180","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"a436ff0616cd485d9ad02a8eddc12852","version":"2c7cee0009754224a1897c3b71702a7f"},"installation":{"command":"CP040311.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5205597","datemodified":"2020-12-13T09:22:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/CP045408.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045408.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045408.scexe"],"md5sum":"bef9d721461bfcd78e81b88300d166ee","name":"firmware-hdd-d39e7a7e75-HPG1-5.1.x86_64.rpm","release":"2020-12-13T09:09:04","revision":"0","sha1sum":"a0fad9c0bdcb7f18974da825ad0a196e24f7ba1f","size":"4MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"c20869f6e72044ccb4d2b142b029a1ef","version":"8021b032a54b489d88e228bce812d8b2"},"installation":{"command":"CP040351.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB001000GWCBCおよびMB002000GWCBDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18100453","datemodified":"2021-01-27T21:08:11","file_list":["/CP045626_BUILD_3.data","/CP045626.vmexe","/CP045626.vmexe64","/CP045626.vmfile","/CP045626_VMw.zip","/CP045626.xml","/payload.json","/CP045626_VMw.zip/index.xml","/CP045626_VMw.zip/vendor-index.xml","/CP045626_VMw.zip/metadata.zip","/CP045626_VMw.zip/vib20/CP045626/HPE_bootbank_CP045626_HPG6.3-7.0.0.15843807.vib","/CP045626_VMw.zip/metadata.zip/vendor-index.xml","/CP045626_VMw.zip/metadata.zip/vmware.xml","/CP045626_VMw.zip/metadata.zip/vibs/CP045626-3025599837301764167.xml","/CP045626_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045626_HPG6.3-7.0.0.15843807.xml"],"md5sum":"4455e83a2d2ca6fc8def5589138a0c96","name":"CP045626.zip","release":"2021-01-27T21:05:10","revision":"0","sha1sum":"e518c1edd21c0767ae9449a0deb96529358e4b59","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045626","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"fcc57b2588b04f54a01cb383a7a5a458","version":"f4b470527ea348c0bd7e37c8a1b68a96"},"installation":{"command":"CP040784.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:30:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE, and EO0800JEFPF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n      HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>    <br />\n      None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3328368","datemodified":"2020-12-16T14:01:35","file_list":["cp045566.xml","cpqsetup.exe","HSSCPCD3.rel","payload.json","setup.dll"],"md5sum":"45cf8c486e50cbe71ea5dedc75a4b929","name":"cp045566.exe","release":"2020-12-16T13:53:05","revision":"0","sha1sum":"db8d4727dba75b172329d8a677278beecd5f57f6","size":"3MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c9d950d613945119a93065a8b8651f2","version":"279f3616543447c7b02bbe9752409ce9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:56:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6061721","datemodified":"2020-12-13T09:23:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/CP045411.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/HVLAnAsseFD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD1-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045411.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045411.scexe"],"md5sum":"854eccc676e6c6e03aa58c226e84ab13","name":"firmware-hdd-2c27a7a9a4-HPD1-4.1.x86_64.rpm","release":"2020-12-13T09:10:10","revision":"0","sha1sum":"89c714a6b3a4bccd1ce61cc18a6cc6d10d60307a","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"188f54d508794fafbb14f21866a0ffb5","version":"40ac72e3b3934c77a889dde8726afe6d"},"installation":{"command":"CP041491.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5870331","datemodified":"2020-12-13T09:05:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/CP045407.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/WRH620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045407.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045407.scexe"],"md5sum":"bf55be002caaa7d6a3df8f5576088612","name":"firmware-hdd-bfc4af697b-HPG6-4.1.x86_64.rpm","release":"2020-12-13T08:49:08","revision":"0","sha1sum":"c01736e9873868624f23dd8ac3f3dcc61d9bf888","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"6114e7f77ac240e69cf280b518ec5e27","version":"b04ce171107a45b2975a9fc4d4a243e7"},"installation":{"command":"CP040778.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWFWK and MB002000GWFWL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:14:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 7.0 Mellanox mst driver for Mellanox devices"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"30715","datemodified":"2020-11-24T14:56:58","file_list":["/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip","/cp046317.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vib20/nmst/MEL_bootbank_nmst_4.14.3.3-1OEM.700.1.0.15525992.vib","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vibs/nmst-669545082738554545.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992.xml"],"md5sum":"0f73bbcd3e455aefd5eea58247a0d326","name":"cp046317.zip","release":"2020-11-24T14:55:04","revision":"0","sha1sum":"c8eeba65d25be13a109bf6d4af1afa7180471350","size":"29KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd0345028","20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.14.3.3-1OEM.700.1.0.15525992"}]}],"id":{"product":"3f367d314e5844f2951b656b04957c6e","version":"c7c98ad976964ee49cfa97beac60940c"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T12:47:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>No Enhancement as it is Initial version.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>NMST version&nbsp;4.14.3.3</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"}],"sw_keys":[{"name":"Mellanox-NATIVE-NMST:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"nmst:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.00"},{"DeviceName":"HPE D2220sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-200.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18e2e0d794","Version":"2.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"10497960","datemodified":"2018-09-25T14:32:07","file_list":["/CP037690.vmexe","/CP037690.vmfile","/CP037690.xml","/payload.json","/README.txt"],"md5sum":"d82f1f2519cf2b9430fc0ffb89079f01","name":"CP037690.zip","release":"2018-09-25T19:05:08","revision":"0","sha1sum":"2f5bafd90fe9e2c7428150f044a53d0a972c70cb","size":"10MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef","b99dfb74-f0bc-464f-b418-cd18e2e0d794"],"type_of_change":"0","version":"2.00","vib_list":[]}],"id":{"product":"261bf666a3f24e9b933c66b3d8c0b26e","version":"3a67bb1ce3054cfc875e8346996b113e"},"installation":{"command":"CP037690.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><br />\n<strong>NOTE: </strong>When using ESXi6.0 you must be at upgrade 3 or newer. The required SmartPQI driver is not present in earlier versions of the OS</p>\n\n<p><br />\n<strong>&nbsp; &nbsp; &nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HP Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><br />\n<strong>注記</strong>ESXi6.0を使用するには、アップグレード3以降である必要があります。以前のバージョンのOSには必要なSmartPQIドライバーがありません。</p>\n\n<p><br />\n<strong>      リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HP Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE D2500sbストレージブレード用HPE SASエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-25T19:01:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2220sb","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV &nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6308684","datemodified":"2020-12-13T16:16:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/CP045844.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/GPM883G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045844.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045844.scexe"],"md5sum":"78df50ec015f3f8c59bad39e73ef6d34","name":"firmware-hdd-db687966b4-HPG4-2.1.x86_64.rpm","release":"2020-12-13T16:04:05","revision":"0","sha1sum":"7a671eac6af335d3822fcc76d177f34486d492d6","size":"6MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"225a3736a3d645ae82a85050bf27993e","version":"a6e673e4121147328a8b660f7e4d38f7"},"installation":{"command":"CP043494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br/>\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-07T11:10:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6141854","datemodified":"2020-10-29T15:42:33","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/CP046132.xml","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/U14_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u14-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046132.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046132.scexe"],"md5sum":"a5b220e79ef1605befdfab9bacbf90f5","name":"firmware-system-u14-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-29T15:33:05","revision":"0","sha1sum":"2d057eae727d50f5490fbcd9a1b9fd2bdf8ebb7d","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"c22851f0ee734a8da996d363b5084433","version":"f46a0509d5db4fdb8ac9d718545604ca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL170r/XL190r Gen9（U14）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T20:21:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_242.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.42"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"lang":"ja","x_late":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"34223456","datemodified":"2021-04-06T03:31:03","file_list":["cp046458.xml","cpqsetup.exe","ilo5_242.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"md5sum":"c3010b840413356adbe7c39a7a4ca676","name":"cp046458.exe","release":"2021-04-06T03:29:06","revision":"0","sha1sum":"6f47a5c2a3bee91fc372b5ec593d606f1aa98173","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"2","version":"2.42"}],"id":{"product":"8384f9a8878649da8d668b07fb30c48e","version":"c7214d5cb19c4e6fb1becffff91bccd0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Install the firmware using one of these options:</strong></p>\n\n<ul>\n\t<li>Run the Component on the host to be updated.<br />\n\tThe component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />\n\t&nbsp;</li>\n\t<li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:\n\t<ul>\n\t\t<li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li>\n\t\t<li>Use the HPE Lights-Out Configuration Utility, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li>\n\t\t<li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li>\n\t\t<li>Use the Directory Migration Utility, contained in the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Vista (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"edition":"ent","major":"6","minor":"0","name":"Microsoft Windows Vista Enterprise (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"5","minor":"1","name":"Microsoft Windows XP 64-Bit Edition","platform":"NT64","sr":"OEM"},{"major":"5","minor":"2","name":"Microsoft Windows XP Professional x64 Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-16T04:50:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to import large sized LDAP CA certificate</li>\n\t<li>Support enablement for latest Intel Persistence Memory</li>\n\t<li>iLO GUI to display the Host Operating System Version</li>\n\t<li>Display platform Resiliency and Serviceability (RAS) policy in iLO GUI</li>\n\t<li>Added standard redfish schema support for Computer System &ndash; Reset, Graceful restart actions&nbsp;</li>\n\t<li>Real CPU temperature is reported in addition to normalized temperature (this feature requires ROM 2.40 version)</li>\n\t<li>Support for Active Health System logging by RDE ( Redfish Device Enablement ) enabled devices</li>\n\t<li>Support alerting feature for RDE ( Redfish Device Enablement ) enabled devices&nbsp;</li>\n\t<li>Ability to control LED for locating direct attached SATA drives</li>\n\t<li>Ability to reset power for direct attached SATA drives&nbsp;</li>\n\t<li>Added write protect setting feature for Liquid cooled Delta/Redstone GPU cards.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>iLO 5 reporting incorrect Power Supply count with iLO 5 v2.10</li>\n\t<li>Continuous logging to IML of a CHIF Error running ESXi with iLO 5 v1.46</li>\n\t<li>Random messages &quot;smad[]: No response from iLO for Hello&quot; seen in certain Operating Systems&nbsp;</li>\n\t<li>Incorrect MAC address shown in iLO for Synergy 4820C network adapter</li>\n\t<li>InfiniBand card not syncing with Oneview in iLO 5 v2.30</li>\n\t<li>Copy/paste may not work for more than 255 characters to VSP terminal in Linux platforms&nbsp;</li>\n\t<li>547FLR / 1100Q NIC may reset to default mode after flashing from 1.48 to 2.xx</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>- Added Server Identity (iLO IDevID, iLO LDevID, System IDevID, System IAK and Platform certificates)&nbsp;<br />\n&nbsp; capability to uniquely identify a server across networks that is cryptographically verifiable<br />\n- EAP-TLS based authentication for onboarding into an 802.1X access-controlled network<br />\n- Enabled support for Intel VROC</p>\n\n<ul>\n\t<li>Device discovery and inventory of VROC SATA Controller and drives attached to it</li>\n\t<li>Firmware inventory of Intel VROC(VMD NVMe RAID) and VROC SATA Controller</li>\n</ul>\n\n<p>- Extend size for firmware versions supported to 48 bytes<br />\n- Liquid Cooling support for Apollo systems<br />\n- Server Platform Services Descriptor verification and recovery<br />\n- Enabled Discovery, Inventory and Thermal support for Pensando Cloud Adapters</p>\n\n<ul>\n\t<li>P41849-B21: Pensando DSP DSC-25 Cld-SP 10/25Gb Card</li>\n\t<li>P41852-B21: Pensando DSP DSC-100 Cld-SP 100Gb Card</li>\n</ul>\n\n<p>- For Synergy, restricted the capability to change below settings.</p>\n\n<p>&nbsp; Note : Changes to these settings can affect communication between One-view and iLO</p>\n\n<ul>\n\t<li>iLO Web service&nbsp;</li>\n\t<li>iLO Web service Non-SSL Port</li>\n\t<li>Web server SSL Port</li>\n\t<li>iLO RIBCL Interface</li>\n</ul>\n","curr_fixes_x_late":"<p>- Corrected Product Name listed under Device Inventory as &quot;NVIDIA Quadro M3000SE&quot;, that was wrongly listed as &quot;Synergy 75W MXM Mezzanine&quot; with iLO firmware v2.16 and higher<br />\n- iLO stops monitoring the second Pensando card after the first one fails with a PCIe error<br />\n&nbsp;</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920/e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1336.0-1//firmware//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C220A","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. \n\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7621384","datemodified":"2021-01-22T09:42:05","file_list":["brcmflashStandalone-windows-12.0.1336.0-1/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/firmware/oc14-12.0.1336.0.ufi","brcmflashStandalone-windows-12.0.1336.0-1/win/","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/RM.INI","cp042529.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1336.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"c76faf0affe3a42e2bbd36f7d16d2b7f","name":"cp042529.exe","release":"2021-01-22T09:28:06","revision":"0","sha1sum":"42578c32cab81038d1b72fee998841465a5a634b","size":"7MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153","a6b1a447-382a-5a4f-10DF-0720103C8144","a6b1a447-382a-5a4f-10DF-0722103C8144","a6b1a447-382a-5a4f-10DF-0724103C8144","a6b1a447-382a-5a4f-10DF-0720103C220A","a6b1a447-382a-5a4f-10DF-0724103C220A","a6b1a447-382a-5a4f-10DF-0722103C220A"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"3792f94db020466a8427ae92f8d0ad7e","version":"8613ef466b6b4da59e365606398b5ebd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p dir=\"LTR\">Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>ダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Microsoft Windows Server 2012R2/2016/2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:44:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>Contains:<br />\nCNA (XE100 series) firmware 12.0.1280.5</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<p>UEFI:</p>\n\n<ul>\n\t<li>HPE FlexFabric 20Gb 2-port 650FLB Adapter and HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;does not complete&nbsp;to create boot source on 2nd port</li>\n</ul>\n\n<p>Firmware:</p>\n\n<ul>\n\t<li>Light Emiiting Diode(LED) is in&nbsp;invalid state when disable the port under Unified Extensible Firmware Interface (UEFI)</li>\n\t<li>Duplicate Entries found in firmware report under NIC details for few adaptors.</li>\n\t<li>Full adapter name is not displayed for HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;in some Rom Based Setup Utility (RBSU).</li>\n\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.</p>\n\n<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33595569","datemodified":"2021-01-28T12:00:42","file_list":["payload.json","U39_2.42_01_23_2021.signed.flash","U39_2.42_01_23_2021.xml"],"md5sum":"e49d95a5c97afb10621b10bd9eb997ce","name":"U39_2.42_01_23_2021.fwpkg","release":"2021-01-28T11:56:10","revision":"0","sha1sum":"145976a07ea79496a54f096717e83225ce03c61c","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"5410a19b6b464f26bd8935266bc1120d","version":"889eff9d4cd3466d8f5fbc1b1f05e4a4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"tw","x_late":"<br type=\"_moz\"/>\n"},{"lang":"en","x_late":"<br type=\"_moz\" />\n"},{"lang":"ko","x_late":"<br type=\"_moz\"/>\n"},{"lang":"cn","x_late":"<br type=\"_moz\"/>\n"},{"lang":"ja","x_late":"<br type=\"_moz\"/>\n"}],"files":[{"bytes":"8705031","datemodified":"2020-10-29T10:36:42","file_list":["/CP046133.vmexe","/CP046133.vmexe64","/CP046133.vmfile","/CP046133.xml","/README.txt"],"md5sum":"733e94a24f71237dca86bb8af5611841","name":"CP046133.zip","release":"2020-10-29T15:34:05","revision":"0","sha1sum":"5ae9c6a44a3a307925484d406992e5fca52d4919","size":"8MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"48fa0a59576f43e996cb7cfa8674ff57","version":"2f3bb5ac015646aa967c69284bb788f8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant XL170r/XL190r Gen9 (U14) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant XL170r/XL190r Gen9 (U14)サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T20:26:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Ver. 2.76_10-21-2019 (B)&nbsp; contains updates to the component packaging and is functionally equivalent to ver. 2.76_10-21-2019.&nbsp; It is not necessary to upgrade with Revision B if a previous component Revision was used to upgrade the system ROM to version 2.76_10-21-2019.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-0151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"U14","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD3"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWFVK and MB006000JWFVL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16147209","datemodified":"2021-01-28T05:58:51","file_list":["/CP045632_BUILD_4.data","/CP045632.vmexe","/CP045632.vmexe64","/CP045632.vmfile","/CP045632_VMw.zip","/CP045632.xml","/payload.json","/CP045632_VMw.zip/index.xml","/CP045632_VMw.zip/vendor-index.xml","/CP045632_VMw.zip/metadata.zip","/CP045632_VMw.zip/vib20/CP045632/HPE_bootbank_CP045632_HPD3.4-7.0.0.15843807.vib","/CP045632_VMw.zip/metadata.zip/vendor-index.xml","/CP045632_VMw.zip/metadata.zip/vmware.xml","/CP045632_VMw.zip/metadata.zip/vibs/CP045632--186581255529549263.xml","/CP045632_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045632_HPD3.4-7.0.0.15843807.xml"],"md5sum":"ecee9d556ef26375074d7c8f9c7de707","name":"CP045632.zip","release":"2021-01-28T05:56:07","revision":"0","sha1sum":"df23dad1667b3acaf060b42274cb7ac25c942849","size":"15MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045632","version":"HPD3.4-7.0.0.15843807"}]}],"id":{"product":"0e268c49682a427da167d2f123ccafaf","version":"27150f7cb70c4c5d90b833ae651b1e3c"},"installation":{"command":"CP041749.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:35:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>BIOS A42_2.40_09_24_2020 needs iLO 5 v2.40 Pass 10 as the minimum supported version.</p>\n"}],"files":[{"bytes":"34210600","datemodified":"2021-02-25T07:00:53","file_list":["A42_2.40_02_23_2021.signed.flash","cp044529.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"4d603eb6ccd3d63d547c64e3e13f0f9c","name":"cp044529.exe","release":"2021-02-25T06:59:11","revision":"0","sha1sum":"da6774f6632f1e53d5cfb71f1da755ff2cb2c459","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"f74d125372264713b4a9d8ebea70260d","version":"9e6484992fe24af5921c46d0834655fe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-10T02:20:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"202280","datemodified":"2021-01-09T00:14:28","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"61f4611c61d36905f4775f5b570e10d2","name":"kmod-hp-ixgbe-5.9.4-1.rhel7u9.x86_64.rpm","release":"2021-01-08T23:59:05","revision":"0","sha1sum":"17bf7ef8e17eb1fd81d13a89b7559658d18699d8","size":"197KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"202282","datemodified":"2021-01-09T00:19:31","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"d32087f4889606ded4ccefc7bfee7fb1","name":"kmod-hp-ixgbe-5.9.4-1.rhel7u8.x86_64.rpm","release":"2021-01-08T23:59:05","revision":"0","sha1sum":"db880252d9d93e8bd6f04022f15d6934bb08efe2","size":"197KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"e2ded6c100dc4bec88c153fd9c85c964","version":"58bbcff8f5434dfb94e18c4a5443a13d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4138291","datemodified":"2021-01-28T10:13:37","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/qlgc-qla2xxx","./lib/modules/4.12.14-94.41-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.12.14-94.41-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"5ecb8cf60c6bc3eba54468c809b9345d","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-28T09:59:06","revision":"0","sha1sum":"d36e5bfc0f8c4fe1ea0f32b8f34b4a9ee0458f88","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"a9c6682103ab49b8854f0561c589b05c","version":"33b56164c4cb40c9b2ba8fd228c89e63"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 4 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Driver for:</p>\n\n<p>SuSE Linux Enterprise Server 12 service pack&nbsp;4 (SLES12 sp4)&nbsp;version 10.01.00.64.12.4-k1b</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi - Smart Array&nbsp;and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and&nbsp;P841<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; 7.00(D)</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 7.00(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;7.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Initial release for Snap4</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"9640222","datemodified":"2021-03-25T13:55:58","file_list":["/CP047335.vmexe","/CP047335.vmexe64","/CP047335.vmfile","/CP047335.xml","/payload.json","/README.txt"],"md5sum":"b0535676e0bf0ee10e6e8d954a9f5810","name":"CP047335.zip","release":"2021-03-25T13:41:06","revision":"0","sha1sum":"c82633aea1b1a6d0dbec617a9851e7c548336611","size":"9MB","target_guids":[],"type_of_change":"1","version":"7.00","vib_list":[]}],"id":{"product":"820627433dee4bc3a4a1adb64a0c3d74","version":"05408484df0845c39625044662151743"},"installation":{"command":"CP047335.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.4-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.4 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec21fe94e4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.4.6-0","description":"HP ProLiant Smart Array Controller Driver version 3.4.6 or greater is required and should be already active"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and  P841"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - SmartアレイおよびSmart HBA H240ar、H240nr、H240、H241、H244br、P240nr、P244br、P246br、P440ar、P440、P441、P542D、P741m、P840、P840arおよびP841"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-04-23T09:30:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Improved flash engine efficiency</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"21be103c","sw_key_expectedpath":"firmware"},{"name":"21CD103c","sw_key_expectedpath":"firmware"},{"name":"21cb103c","sw_key_expectedpath":"firmware"},{"name":"21BD103c","sw_key_expectedpath":"firmware"},{"name":"21c6103c","sw_key_expectedpath":"firmware"},{"name":"21c1103c","sw_key_expectedpath":"firmware"},{"name":"21c5103c","sw_key_expectedpath":"firmware"},{"name":"21cc103c","sw_key_expectedpath":"firmware"},{"name":"21c2103c","sw_key_expectedpath":"firmware"},{"name":"21c8103c","sw_key_expectedpath":"firmware"},{"name":"21c3103c","sw_key_expectedpath":"firmware"},{"name":"21bf103c","sw_key_expectedpath":"firmware"},{"name":"21c7103c","sw_key_expectedpath":"firmware"},{"name":"21ca103c","sw_key_expectedpath":"firmware"},{"name":"21ce103c","sw_key_expectedpath":"firmware"},{"name":"21c0103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2756998","datemodified":"2021-03-22T15:38:15","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"b9428e7fbaeb3aad617e87cf860b1034","name":"amsd-2.4.1-1571.4.sles12.x86_64.rpm","release":"2021-03-22T15:29:07","revision":"0","sha1sum":"0444e7c7e25c148e6324552173cbe3d7e5c4fb60","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"2","version":"2.4.1"}],"id":{"product":"5e1877c3b3394cf696fd1e1223a16f2b","version":"97394576b911487e84d30cbc17e4e4cc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-04T16:34:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following item:</p>\n\n<ul>\n\t<li>A customer may experience smad periodically reporting:&nbsp;No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp; Customers experiencing this issue are requested to update to amsd version 2.3.1.&nbsp;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This release contains the following enhancements:</p>\n\n<ul>\n\t<li>Enhance the robust communication with iLO. The enhancement has a proper process exist and OS signal handling.</li>\n\t<li>Enhance the SMA logging system for better recording of the communication events.</li>\n\t<li>The AMSD reports the Open NIC controllers SN to align with iLO for avoiding the un-sync information.</li>\n</ul>\n","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed a small amount of memory leak as outlined in the Customer Advisory,&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\">a00053824en_us</a></li>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp;</li>\n\t<li>The cpqIde service not able to start while the AMSD configuration is agent mode.</li>\n\t<li>Addressed&nbsp;buffer overflow issues in select&nbsp;corner cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"5519983","datemodified":"2020-12-13T08:38:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/CP045386.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/HCFL4CD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045386.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045386.scexe"],"md5sum":"b452e2b2f6466f34c2d5f1f26a63f307","name":"firmware-hdd-8a2c06af48-HPD6-8.1.x86_64.rpm","release":"2020-12-13T08:25:08","revision":"0","sha1sum":"df359e0d021439c51e3bf444161303539cf15d31","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"121d8116603e47a49293c085684f3fa1","version":"e7964206ce6e4b73a4b4c924d0a87092"},"installation":{"command":"CP040315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:43:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.44_11_13_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.44 (11/13/2020)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33590715","datemodified":"2020-11-18T02:37:24","file_list":["A41_2.44_11_13_2020.signed.flash","A41_2.44_11_13_2020.xml","payload.json"],"md5sum":"5213ee59e51c4cddadb57ee9679a990e","name":"A41_2.44_11_13_2020.fwpkg","release":"2020-11-18T02:33:10","revision":"0","sha1sum":"7a6c0cc3d5ddb0d3b36b09ff72919009d5c1e222","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"1","version":"2.44_11-13-2020"}],"id":{"product":"14652a1a392747089da4a4254064ac9d","version":"83b15bbed45a4f5290f73da5e1d7a8b7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL325 Gen10（A41）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T02:33:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. </p><p>Added support to increase the maximum amount of system memory to 8TB.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed a rare issue where the system may fail to boot after a warm reset.</p><p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p><p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB6000GEBTP Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデルMB6000GEBTPのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows  (x64) - MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     HPG3<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3225296","datemodified":"2020-12-16T17:40:03","file_list":["cp045549.xml","cpqsetup.exe","HAHC6FG4.rel","payload.json","setup.dll"],"md5sum":"2ec5e8e501058bec8ab89db026e4fb2a","name":"cp045549.exe","release":"2020-12-16T17:29:09","revision":"0","sha1sum":"3b5f13861c296c9fbc2b1e5a7389653909d4868c","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e2d7a4e705f34372b47092c82c533260","version":"8ec18abaa1ca4b348246ecf9bc8a2620"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEBTP Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:49:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1052"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The x64 Smart Component provides firmware for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\nOnline ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1052<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1047<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Support for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"1715608","datemodified":"2021-02-08T09:58:44","file_list":["cp044566.xml","cpqsetup.exe","HPE_NS204i_Gen10P_1052.bin","mnv_cli.exe","payload.json","setup.dll"],"md5sum":"47cc0c2ba35f17dd1ba629c4ed6fa2eb","name":"cp044566.exe","release":"2021-02-08T09:56:05","revision":"0","sha1sum":"88a08c486e9a8501b45e701673488b907e5353fe","size":"1MB","target_guids":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"type_of_change":"1","version":"1.0.14.1052"}],"id":{"product":"149ff2208f3a4a13b7c145a5ab625b8a","version":"a0b2c3531e79499caa1aa7acf06abfb9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Flash for Windows - HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"0310","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-224115900310","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030f","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030e","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-07-12T09:05:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Firmware Smart Component release for HPE Gen10+ Boot Controller</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Support for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"03101590","sw_key_expectedpath":"firmware:sd:"},{"name":"030E1590","sw_key_expectedpath":"firmware:sd:"},{"name":"030F1590","sw_key_expectedpath":"firmware:sd:"},{"name":"02F61590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"954366","datemodified":"2021-03-08T18:00:27","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"9fbe61d65c431f81c9be90ea4411938f","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"0546c14ec984fd6a5be1158c3920cdcfbee5b2f6","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"953499","datemodified":"2021-03-08T17:57:49","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"6d7f1c3af7361bf93c309b2a77956caf","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"963ca324b280912edc8713043fc0ccff922fb5e0","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"72bb108f558244ddb21ec2debe092df6","version":"7731e7e28e18499896b56c654e829017"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0111"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"14822256","datemodified":"2021-01-21T07:30:48","file_list":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff","Config.xml","cp046461.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"md5sum":"cb7efea32edb0ea9c7ecd33e3dd1ea99","name":"cp046461.exe","release":"2021-01-21T07:27:07","revision":"0","sha1sum":"12eefe053fa592600a2e43473d3701d38c15ace9","size":"14MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0111"}],"id":{"product":"33474bdb31ec42199bc00637b81a4d15","version":"e9a4c3f67ba64794afa19f13e5d466c2"},"installation":{"command":"cpqsetup.exe","command_params":"/t D8000 /v 0111 /i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff /i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff /l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"HPE D8000 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-16T05:20:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>In STD INQUIRY RESPONSE, the ErrM bit was always being set. The ErrM bit indicates that the enclosure firmware detects a mismatch in any of its package versions and the firmware version of a FRU component. The issue was due to an incorrect version of PSU firmware being included and that has been fixed.</p>\n\t</li>\n\t<li>\n\t<p>After installing the latest firmware on the enclosure I/O modules, the SES targets could not be discovered on the host. The virtual phy bit in SMP DISCOVER RESPONSE, which is used by the Microchip smartpqi HBA, was det for the virtual phy of the I/O module.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v183134/D8000_P20366-004.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Incorrect programming of the&nbsp;PHY ERROR COUNTERS parameter caused the amber LED to be lit, resulting in a false warning. The counter condition was corrected and the amber LED now functions correctly.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2012 R2で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1534328","datemodified":"2021-01-08T16:35:08","file_list":["cp045127.xml","cpqsetup.exe","cp_data.xml","i40eb64.cat","i40eb64.din","i40eb64.inf","i40eb64.sys","i40ebmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicIn40B.dll"],"md5sum":"a6d9e666d39e6356d0ca5b9ad9abb760","name":"cp045127.exe","release":"2021-01-08T16:21:06","revision":"0","sha1sum":"0d32c5f81665d5e71604c136281e290c3eb4a132","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"50dc9c8a9cbe4f0ba1dfe1509168e910","version":"fe570d892b914b3bb1fdf0f5a38a610a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Intel i40ebドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product added implementation of Advanced Link Speed functionality in Physical Function (PF) driver that are supports dynamic link speed changes.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which Blue Screen of Death （BSOD） (0x133) occurred with Remote Access Role service during shutdown.</li>\n\t<li>This product correct an issue which system crashed after few modifying Intel&reg; Advanced Network Services (Intel&reg; ans) Team type with tagged Virtual Local Area Network (VLAN).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40eb64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4190425","datemodified":"2021-02-04T07:08:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/CP045792.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045792.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045792.scexe"],"md5sum":"572c0c23961b57585563ee896557637b","name":"firmware-d3000-5.04-2.1.x86_64.rpm","release":"2021-02-04T06:59:05","revision":"0","sha1sum":"fe663ece143a8906d78367dbe1c823dda14a3edb","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"id":{"product":"d6810024a18142b0a4b8ec4db68a4e55","version":"e7e8bbbc3c5f483ab2e24e384ee40f35"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"Linux (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-27T07:23:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v177052/D3000_P07231-006.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v191363/D3000_v5.04B.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGE"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGE"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGE"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGE"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGE"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGE"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16367639","datemodified":"2021-01-28T11:28:43","file_list":["/CP045678_BUILD_4.data","/CP045678.vmexe","/CP045678.vmexe64","/CP045678.vmfile","/CP045678_VMw.zip","/CP045678.xml","/payload.json","/CP045678_VMw.zip/index.xml","/CP045678_VMw.zip/vendor-index.xml","/CP045678_VMw.zip/metadata.zip","/CP045678_VMw.zip/vib20/CP045678/HPE_bootbank_CP045678_HPGE.4-7.0.0.15843807.vib","/CP045678_VMw.zip/metadata.zip/vendor-index.xml","/CP045678_VMw.zip/metadata.zip/vmware.xml","/CP045678_VMw.zip/metadata.zip/vibs/CP045678--3377094694175741954.xml","/CP045678_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045678_HPGE.4-7.0.0.15843807.xml"],"md5sum":"c05c1ddca0b9205f431192b714c2c5dc","name":"CP045678.zip","release":"2021-01-28T11:26:04","revision":"0","sha1sum":"2e56d0b16e79417f09926d2a86aaa2777a5a188f","size":"15MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGE","vib_list":[{"name":"CP045678","version":"HPGE.4-7.0.0.15843807"}]}],"id":{"product":"d2d1d9a632e643969f5a1799b83f981a","version":"5430cfb3ac8f44c48ffa8734e1e52191"},"installation":{"command":"CP041315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:16:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models:MB6000JVYZD and MB4000JVYZC"},{"lang":"ja","x_late":"このSmartコンポーネントは、ドライブモデル：MB6000JVYZDおよびMB4000JVYZCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17496763","datemodified":"2021-01-28T16:16:53","file_list":["/CP045783_BUILD_3.data","/CP045783.vmexe","/CP045783.vmexe64","/CP045783.vmfile","/CP045783_VMw.zip","/CP045783.xml","/payload.json","/CP045783_VMw.zip/index.xml","/CP045783_VMw.zip/vendor-index.xml","/CP045783_VMw.zip/metadata.zip","/CP045783_VMw.zip/vib20/CP045783/HPE_bootbank_CP045783_HPD4.3-7.0.0.15843807.vib","/CP045783_VMw.zip/metadata.zip/vendor-index.xml","/CP045783_VMw.zip/metadata.zip/vmware.xml","/CP045783_VMw.zip/metadata.zip/vibs/CP045783--3007864962788978680.xml","/CP045783_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045783_HPD4.3-7.0.0.15843807.xml"],"md5sum":"e3f4aa18da0adb7ff434df67f79bbc39","name":"CP045783.zip","release":"2021-01-28T16:14:04","revision":"0","sha1sum":"ea1a8e5d6da9e3acbb54207f4460e8db95fff74c","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045783","version":"HPD4.3-7.0.0.15843807"}]}],"id":{"product":"d9159bc289514e83950fce1ae62143a1","version":"ff5401dfffe84d69b503488a6ea09d9c"},"installation":{"command":"CP040636.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SDD Flash Component for VMware ESXi  - MB6000JVYZD and MB4000JVYZC Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - MB6000JVYZDおよびMB4000JVYZCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-27T05:18:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6234113","datemodified":"2020-11-04T02:32:37","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/CP046141.xml","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/P86_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p86-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046141.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046141.scexe"],"md5sum":"6d9bc7c7647da3b949258d7196b41906","name":"firmware-system-p86-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-04T02:23:05","revision":"0","sha1sum":"805b115cc1227783d0a8de7d080d2489d623a81b","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"74e7399cb8c44299934a1057e39251e9","version":"79a03ada4e4b46f8bcbf206b7156757c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL120 Gen9 (P86) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL120 Gen9（P86）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T02:28:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"}],"sw_keys":[{"name":"P86","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048992af248","Version":"3H5Q"},{"DeviceName":"MZXL51T6HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-364889da9feb","Version":"3H5Q"},{"DeviceName":"MZXL53T2HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-3248cfd7fef8","Version":"3H5Q"},{"DeviceName":"MZXL56T4HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-3448c531f122","Version":"3H5Q"},{"DeviceName":"MZXL5960HBHQ-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-3048d9dd07de","Version":"3H5Q"},{"DeviceName":"MZXL51T9HBJR-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-39483a8fb090","Version":"3H5Q"},{"DeviceName":"MZXL53T8HBLS-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38488ed832eb","Version":"3H5Q"},{"DeviceName":"MZXL57T6HALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-36489d1db6a9","Version":"3H5Q"},{"DeviceName":"MZXL515THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-544832bf723c","Version":"3H5Q"},{"DeviceName":"MZXL512THALA-000","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK73H5Q.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-54488858a5c5","Version":"3H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs: VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07 Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37 Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; 3H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li style=\"text-align:left\">SR932i-a is reporting incomplete drive model number(truncating last 2 bytes) and firmware version (truncating first 4 bytes), due to this we are creating this new component to support 4 bytes firmware version when the drives are connected behind this controller.</li>\n</ul>\n"}],"files":[{"bytes":"25448404","datemodified":"2021-02-11T15:55:42","file_list":["/CP046694_BUILD_3.data","/CP046694.vmexe","/CP046694.vmexe64","/CP046694.vmfile","/CP046694_VMw.zip","/CP046694.xml","/payload.json","/CP046694_VMw.zip/index.xml","/CP046694_VMw.zip/vendor-index.xml","/CP046694_VMw.zip/metadata.zip","/CP046694_VMw.zip/vib20/CP046694/HPE_bootbank_CP046694_3H5Q.3-7.0.0.15843807.vib","/CP046694_VMw.zip/metadata.zip/vendor-index.xml","/CP046694_VMw.zip/metadata.zip/vmware.xml","/CP046694_VMw.zip/metadata.zip/vibs/CP046694-2674466974272124049.xml","/CP046694_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046694_3H5Q.3-7.0.0.15843807.xml"],"md5sum":"7ff7492c093477237ac5eb16ac512ed7","name":"CP046694.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"d379a3d174f575c1bc415c36ed8d352f4e0f3a71","size":"24MB","target_guids":["4d2340a5-585a-354c-3830-3048992af248","4d2340a5-585a-354c-3154-364889da9feb","4d2340a5-585a-354c-3354-3248cfd7fef8","4d2340a5-585a-354c-3654-3448c531f122","4d2340a5-585a-354c-3936-3048d9dd07de","4d2340a5-585a-354c-3154-39483a8fb090","4d2340a5-585a-354c-3354-38488ed832eb","4d2340a5-585a-354c-3754-36489d1db6a9","4d2340a5-585a-354c-3135-544832bf723c","4d2340a5-585a-354c-3132-54488858a5c5"],"type_of_change":"1","version":"3H5Q","vib_list":[{"name":"CP046694","version":"3H5Q.3-7.0.0.15843807"}]}],"id":{"product":"6a808075e9fa4bc19e7d11fd17511784","version":"c874e98801324f498e5155ab5c91b5a9"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"*REMOVED* Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000 Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T07:44:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting .</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>*REMOVED* - Version 3H5Q(B) is NO LONGER AVAILABLE for download. Working version MPK73H5Q supporting full firmware version is now available from the following OS-specific URLs:</p>\n\n<p>VMware: MPK73H5Q Firmware For VMware Operating Systems, https://www.hpe.com/global/swpublishing/MTX-bc5a85e2da894acc87edff7b07</p>\n\n<p>Windows: MPK73H5Q Firmware for Windows Operating Systems, https://www.hpe.com/global/swpublishing/MTX-eb2b1b0ee298477fb52d02948f</p>\n\n<p>Linux: MPK73H5Q Firmware for Linux Operating Systems, https://www.hpe.com/global/swpublishing/MTX-c2d518c8671942018d4084aa37</p>\n\n<p>Version MPK73H5Q will be available soon in Service Pack for ProLiant. For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us. This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000, MZXL51T6HBJR-000, MZXL53T2HBLS-000, MZXL56T4HALA-000, MZXL512THALA-000, MZXL5960HBHQ-000, MZXL51T9HBJR-000, MZXL53T8HBLS-000, MZXL57T6HALA-000 and MZXL515THALA-000</p>\n\n<p>Working version MPK73H5Q resolves the following issue:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Code change to set &#39;Slot Clock Configuration bit in Link Status register.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL53T2HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL512THALA-000","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO001600KWZQPおよびMO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25167745","datemodified":"2021-01-28T22:41:58","file_list":["/CP045989_BUILD_7.data","/CP045989.vmexe","/CP045989.vmexe64","/CP045989.vmfile","/CP045989_VMw.zip","/CP045989.xml","/payload.json","/CP045989_VMw.zip/index.xml","/CP045989_VMw.zip/vendor-index.xml","/CP045989_VMw.zip/metadata.zip","/CP045989_VMw.zip/vib20/CP045989/HPE_bootbank_CP045989_HPK5.7-7.0.0.15843807.vib","/CP045989_VMw.zip/metadata.zip/vendor-index.xml","/CP045989_VMw.zip/metadata.zip/vmware.xml","/CP045989_VMw.zip/metadata.zip/vibs/CP045989-4392114508414479504.xml","/CP045989_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045989_HPK5.7-7.0.0.15843807.xml"],"md5sum":"5f94a76046ce6d719640a3760420c0d8","name":"CP045989.zip","release":"2021-03-04T00:00:00","revision":"1","sha1sum":"c3a51a3e0f2cdac470e1e44d56dda2dac4ac025f","size":"24MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"1","version":"HPK5","vib_list":[{"name":"CP045989","version":"HPK5.7-7.0.0.15843807"}]}],"id":{"product":"bb888c4588ea4d4989702d85035e6fce","version":"b69938d9ef3249f1ab4a0417646ebf51"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:30:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"124967","datemodified":"2021-01-08T22:11:29","file_list":["/cp042678.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.670.0.0.8169922.vib","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vibs/igbn-4393841119758955275.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922.xml"],"md5sum":"a334f834563ec016886aa103fec982ab","name":"cp042678.zip","release":"2021-01-08T22:10:04","revision":"0","sha1sum":"e0b7baca4b81939265e3fb721aa1e39a53637989","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"91032ccb9de142bdafa34467279d1727","version":"3ef1fafc2936477aaea9855f5787049e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where race condition during NIC adapter reset.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19187482","datemodified":"2021-02-03T03:34:06","file_list":["/CP045903.vmexe","/CP045903.vmfile","/CP045903_VMw.zip","/CP045903.xml","/payload.json","/README.txt","/CP045903_VMw.zip/index.xml","/CP045903_VMw.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip","/CP045903_VMw.zip/vib20/CP045903/HPE_bootbank_CP045903_1.0.1-6.7.0.7535516.vib","/CP045903_VMw.zip/metadata.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip/vmware.xml","/CP045903_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045903_1.0.1-6.7.0.7535516.xml","/CP045903_VMw.zip/metadata.zip/vibs/CP045903-815716802762803397.xml"],"md5sum":"d6025d11031c1568d8eab8b71bb3ff06","name":"CP045903.zip","release":"2021-02-03T03:39:04","revision":"0","sha1sum":"f8d1daa1a0a32987ed82d774010a14b96cf560f9","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.5","vib_list":[{"name":"CP045903","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"67519506663b4d259181b3f43ca2db43","version":"86f9d0e7891b4a37a4f6e38fd32f7de6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.08-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.08"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE 12Gb/s SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.08<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.22<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.22<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;</strong>Added support for UBM Backplanes</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3614080","datemodified":"2021-01-28T14:39:06","file_list":["cp044964.xml","cpqsetup.exe","firmware-Signed-5.08-build-000.bin.fw","payload.json","setup.dll"],"md5sum":"fa0bd0a8513b4d1840a707b68390ed59","name":"cp044964.exe","release":"2021-01-28T14:25:04","revision":"0","sha1sum":"beb8de9f423a6c7fe41f232f707dff7a1e7b05fb","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"0","version":"5.08"}],"id":{"product":"b57ffa2f7fe942a89e589fe3043c5ffa","version":"a442fc9b8e35484eab8de0e83ad7665f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.31またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"面向 Windows (x64) 的在线 ROM 刷新组件 – 适用于 HPE 智能阵列控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 扩展器固件"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 – HPE 12Gb/s SAS 擴充卡韌體，適用於 HPE Smart Array 控制器和 HPE HBA 控制器"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS Expander 펌웨어"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T15:31:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Gen10 plus UBM type 1/2/3 backplanes</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Smart Carrier Authentication Failure issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This smart component contains the HPE Lights-Out Online Configuration Utility which is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the operating system without requiring a reboot of the server."},{"lang":"ja","x_late":"このSmartコンポーネントには、サーバーを再起動しないでオペレーティングシステムからProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティである、HPE Lights-Outオンライン設定ユーティリティが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"1263224","datemodified":"2020-12-03T03:18:33","file_list":["cp046381.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"md5sum":"ce511beec2b9357e9e9a1352493db989","name":"cp046381.exe","release":"2020-12-03T03:09:06","revision":"0","sha1sum":"b598eeb9cc87aac2a63b84171c0ff20e04b75d12","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"type_of_change":"0","version":"5.5.0.0"}],"id":{"product":"C9113","version":"6c968b1872524d75a306b957bc4aa2e6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":28,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Uninstall any older version of HPONCFG before installing this version of HPONCFG.</p>\n\n<p>Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.</p>\n\n<p>Click on the install button to install the utlility on the server. This does not require a reboot.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>The utility will be installed in the program files under the directory HewlettPackardEnterprise\\HPONCFG\\</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>A shortcut for the graphical interface of the utility will be provided in &quot;Start Menu &gt; Programs &gt; HPE System Tools &gt; HPE Lights-Out Online Configuration Utility&quot;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions"},{"lang":"ja","x_late":"HPE Lights-Out オンライン構成ユーティリティfor Windows x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"160"},"supported_devices":[{"dev":"B204","subdev":"B206","subven":"0E11","target_guid":"a6b1a447-382a-5a4f-0e11-b2040e11b206","type":"pci","ven":"0E11"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Storage Server 2008 x64 Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-03T03:04:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This version of utility specifically contains changes related to updating legacy HP branding and brand&nbsp;<br />\nreferences from prior to the separation of Hewlett-Packard Company to current HPE branding and&nbsp;<br />\nreferences. If you make use of this version existing scripts may break. You may have to update scripts<br />\nto refer to new version.</p>\n","latest_fixes_x_late":"<p>This version does not contain any defect fixes.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed an issue were HPONCFG Windows Smart Component was not installing when SW RAID configuration enabled in RBSU.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HP StorageWorks 600 All-in-One Storage System"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"","value":"HP StorageWorks 1200 All-in-One Storage System"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"W04","value":"HP ProLiant DL320s Storage Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I15","value":"HP ProLiant BL460c Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hponcfg.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6973905","datemodified":"2020-11-04T22:51:34","file_list":["/CP046155.vmexe","/CP046155.vmfile","/CP046155.xml","/README.txt"],"md5sum":"ef7957d140ccec2b3dabf713ede3fa2b","name":"CP046155.zip","release":"2020-11-05T04:49:08","revision":"0","sha1sum":"dcf2b75e407b84950f4ef8744e2936cf676a5968","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"fc0ed88941764df9b650bfbb2dbeee2a","version":"ca77880e543f467fbe19c953c8fae31a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T09:24:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.04.07"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020407.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.04.07"},{"DeviceName":"HPE 81Q 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3262","Version":"03.82.00"},{"DeviceName":"HPE 82Q 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532103C3263","Version":"03.82.00"},{"DeviceName":"HPE 84Q 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Q25A0382.BIN","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2532159000FC","Version":"03.82.00"},{"DeviceName":"HPE SN1000Q 16GB 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E7","Version":"06.04.04"},{"DeviceName":"HPE SN1000Q 16GB 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C17E8","Version":"06.04.04"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4394320","datemodified":"2021-01-22T09:18:20","file_list":["Q25A0382.BIN","QLAFWUpdate.exe","adapters.properties","bk017507.bin","cp044784.xml","cpqsetup.exe","hld60404.bin","installer.dll","mh020407.bin","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"44505d8922dbfe6136aff9ef77a82ec7","name":"cp044784.exe","release":"2021-01-22T09:03:06","revision":"0","sha1sum":"e6921b0449412f61ae133026f9756f8aeab42439","size":"4MB","target_guids":["a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4","a6b1a447-382a-5a4f-1077-2532103C3262","a6b1a447-382a-5a4f-1077-2532103C3263","a6b1a447-382a-5a4f-1077-2532159000FC","a6b1a447-382a-5a4f-1077-2031103C17E7","a6b1a447-382a-5a4f-1077-2031103C17E8","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"635ad6621b8d4c52b8b9de3325345e84","version":"2c3f6375b301448fa3801f2a67a98036"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2012R2/2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:27:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb,&nbsp;16 Gb and 32 Gb&nbsp;products.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>8Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 3.82.00</li>\n\t\t<li>Firmware 8.08.207</li>\n\t\t<li>UEFI 7.00</li>\n\t\t<li>BIOS 3.56</li>\n\t</ul>\n\t</li>\n\t<li>16Gb&nbsp;Fibre Channel Host Bus Adapter:\n\t<ul>\n\t\t<li>Package 6.03.00</li>\n\t\t<li>Firmware 8.08.231</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.43</li>\n\t</ul>\n\t</li>\n\t<li>16Gb/32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;\n\t<ul>\n\t\t<li>Package 1.74.07</li>\n\t\t<li>Firmware 9.03.00</li>\n\t\t<li>UEFI 7.02</li>\n\t\t<li>BIOS 3.64</li>\n\t</ul>\n\t</li>\n\t<li>32Gb&nbsp;Fibre Channel Host Bus Adapter:&nbsp;&nbsp;\n\t<ul>\n\t\t<li>Package 02.03.06</li>\n\t\t<li>Firmware 09.04.01</li>\n\t\t<li>UEFI 7.08</li>\n\t\t<li>BIOS 0.0</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"129146","datemodified":"2021-01-09T01:01:33","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb/igb.ko","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"f4157381674f788190dc0856647c2c28","name":"kmod-hp-igb-6.2.5-1.rhel7u9.x86_64.rpm","release":"2021-01-09T00:53:12","revision":"0","sha1sum":"feccbac439468dd1db96195144eb2c7608387f7f","size":"126KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.2.5-1"},{"bytes":"129158","datemodified":"2021-01-09T01:04:59","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb/igb.ko","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"d3e384c4cbf69e7f3d854ded5a0e04be","name":"kmod-hp-igb-6.2.5-1.rhel7u8.x86_64.rpm","release":"2021-01-09T00:53:12","revision":"0","sha1sum":"c254aefaf49adb980c9af88f474fa38ac445a300","size":"126KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"0","version":"6.2.5-1"}],"id":{"product":"8641d1fe608b4b84a83d535f2b785a88","version":"eaf58d1de1d54779a08eb4e9297d0d50"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驱动程序"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now support <em>HPE Intel Online Firmware Upgrade Utility for Linux x86_64</em>, version (or later) to update firmware</li>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18951534","datemodified":"2021-01-28T06:31:41","file_list":["/CP045634_BUILD_3.data","/CP045634.vmexe","/CP045634.vmexe64","/CP045634.vmfile","/CP045634_VMw.zip","/CP045634.xml","/payload.json","/CP045634_VMw.zip/index.xml","/CP045634_VMw.zip/vendor-index.xml","/CP045634_VMw.zip/metadata.zip","/CP045634_VMw.zip/vib20/CP045634/HPE_bootbank_CP045634_HPG8.3-7.0.0.15843807.vib","/CP045634_VMw.zip/metadata.zip/vendor-index.xml","/CP045634_VMw.zip/metadata.zip/vmware.xml","/CP045634_VMw.zip/metadata.zip/vibs/CP045634--5014346583414590636.xml","/CP045634_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045634_HPG8.3-7.0.0.15843807.xml"],"md5sum":"5a24e23d11e092f8e896b21394476b2a","name":"CP045634.zip","release":"2021-01-28T06:28:05","revision":"0","sha1sum":"0440f101adfbd5cf1538b11cf84a35017c3be8ae","size":"18MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP045634","version":"HPG8.3-7.0.0.15843807"}]}],"id":{"product":"f2578af2166847fd869273fa7aa2c430","version":"290e630370304e4ba2dcfb4bd3fde21c"},"installation":{"command":"CP040789.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:37:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8748745","datemodified":"2020-11-26T06:48:22","file_list":["/CP044793_BUILD_8.data","/CP044793.vmexe","/CP044793.vmexe64","/CP044793.vmfile","/CP044793_VMw.zip","/CP044793.xml","/payload.json","/CP044793_VMw.zip/index.xml","/CP044793_VMw.zip/vendor-index.xml","/CP044793_VMw.zip/metadata.zip","/CP044793_VMw.zip/vib20/CP044793/HPE_bootbank_CP044793_2021.02.01.8-6.5.0.4240417.vib","/CP044793_VMw.zip/metadata.zip/vendor-index.xml","/CP044793_VMw.zip/metadata.zip/vmware.xml","/CP044793_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044793_2021.02.01.8-6.5.0.4240417.xml","/CP044793_VMw.zip/metadata.zip/vibs/CP044793--4719586737095125106.xml"],"md5sum":"dd844b5af293e3a7f6e97a202b22061d","name":"CP044793.zip","release":"2020-11-26T06:44:18","revision":"0","sha1sum":"0cda9ed58499e8b93922fba2f3cc52d403993342","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044793","version":"2021.02.01.8-6.5.0.4240417"}]}],"id":{"product":"da71eb7a509c42f8b6a612623341578e","version":"15b4b850fdc4492d8625bb582580aa27"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:30:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb and 16 Gb&nbsp;products.</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td style=\"width:50px\">UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.03.00</td>\n\t\t\t<td>8.08.231</td>\n\t\t\t<td>7.02</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Address unexpected behavior when Fibre Channel adapters were simultaneously running traffic to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n\t<li>Fibre Channel adapter firmware versions were not showing up as expected in the AHS log.</li>\n\t<li>Port statistics counters would sometimes not update in the event of Loss of Signal or Loss of Sync</li>\n\t<li>link downs would occur during specific frame sequences used by the HPE XP8 array after array-side link loss</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     HPG5<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3991640","datemodified":"2020-12-17T08:57:18","file_list":["cp045515.xml","cpqsetup.exe","payload.json","setup.dll","WRH620G6.rel"],"md5sum":"f2a8ae5b6dec2123fa2cfabbd84ff14a","name":"cp045515.exe","release":"2020-12-17T08:37:08","revision":"0","sha1sum":"48ad9cc7dcfff129c85538357d034c6542057a73","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"57a91e286d3e413c8468376551e64001","version":"30c2e421498640cab5db812faf3e2232"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:37:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"429521","datemodified":"2021-01-28T10:38:09","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"d05e9997e1af4cccca676d73502d5746","name":"brcmfcoe-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-28T10:29:09","revision":"0","sha1sum":"38149f5bb61007fed5ecd36c57dfe99c4532af35","size":"419KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"30776bdc5a7a4fa2b28af4deaeba5bf4","version":"6890db2e465f48a3bc95c6e0027fd610"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 service pack 4 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T06:14:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15688556","datemodified":"2021-01-27T20:14:59","file_list":["/CP045624_BUILD_3.data","/CP045624.vmexe","/CP045624.vmexe64","/CP045624.vmfile","/CP045624_VMw.zip","/CP045624.xml","/payload.json","/CP045624_VMw.zip/index.xml","/CP045624_VMw.zip/vendor-index.xml","/CP045624_VMw.zip/metadata.zip","/CP045624_VMw.zip/vib20/CP045624/HPE_bootbank_CP045624_HPG3.3-7.0.0.15843807.vib","/CP045624_VMw.zip/metadata.zip/vendor-index.xml","/CP045624_VMw.zip/metadata.zip/vmware.xml","/CP045624_VMw.zip/metadata.zip/vibs/CP045624-7312784422039727922.xml","/CP045624_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045624_HPG3.3-7.0.0.15843807.xml"],"md5sum":"0efcbaf0b169fb5c6992850121aa7f90","name":"CP045624.zip","release":"2021-01-27T20:12:16","revision":"0","sha1sum":"d869285d3ef856ef906822d471384f04204bac8c","size":"14MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP045624","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"31f6809eb59143388eb68360c8d0d7ac","version":"33d22e9a53ce463785916d5e05a8dafc"},"installation":{"command":"CP040680.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:28:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration utility is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the Linux operating system without requiring a reboot of the server."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"60457","datemodified":"2020-10-15T06:43:56","file_list":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"md5sum":"3e991c52d2e72cb58e751f64774c0b32","name":"hponcfg-5.6.0-0.x86_64.rpm","release":"2020-10-15T06:39:06","revision":"0","sha1sum":"620aa256a415de5faaf1f9fa5e1f4464ccffd7b3","size":"59KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"type_of_change":"1","version":"5.6.0-0"}],"id":{"product":"db808d6aa2e24648bcc5e3f46d635b1a","version":"640d4499d8c64ee79f546d439f55961d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>If a previous version of the Hponcfg utility has been installed, it must be removed before this package can be installed. To remove the previous version of the package, type the following :</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>To install the package, type:</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>After installation, the executable for hponcfg utility can be found under the directory /sbin.</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p>Hponcfgユーティリティの以前のバージョンをインストールしている場合は、削除しておかないと、このパッケージをインストールできません。パッケージの以前のバージョンを削除するには、次のように入力します：</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>パッケージをインストールするには、次のようにタイプします。</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>インストール後は、/sbinディレクトリにhponcfgの実行可能ファイルが見つかります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T08:36:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Updated the OpenSSL API calls to support Host&#39;s OpenSSL FIPS mode.</p>\n"},{"curr_enhancements_x_late":"<p>Updated product name to HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T).</p>\n","curr_fixes_x_late":"<p>Fixed an issue where HPONCFG was not able to detect openssl library when&nbsp;multiple 64-bit openssl installed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"A48","value":"HPE ProLiant XL215n Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"hponcfg","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp;Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4997826","datemodified":"2020-12-13T15:19:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/4IYRHPG6.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/CP045855.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045855.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045855.scexe"],"md5sum":"1f2a7d9e0eafcf4c4cdd78c935ef92c3","name":"firmware-hdd-c566d63ca0-HPG6-2.1.x86_64.rpm","release":"2020-12-13T15:07:04","revision":"0","sha1sum":"70897f9e9ae331620aee1e3227d1509f9882cbb4","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c6a4f7a1c0f14173802a4263b3ee7551","version":"dd124bc6bd9a4e119eb4915326bf5640"},"installation":{"command":"CP040783.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T18:36:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>HPG6 introduces bug fixes, reliability enhancement and modification in SMART Attributes. Once HPG6 is downloaded, the drive cannot be changed back to an earlier firmware (eg, HPG3).</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB&nbsp;and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4669165","datemodified":"2020-06-25T19:11:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/CP043982.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043982.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043982.scexe"],"md5sum":"d50df066485a036656850055b676ef0c","name":"firmware-hdd-d64642c780-HPK4-5.1.x86_64.rpm","release":"2020-06-25T19:00:05","revision":"0","sha1sum":"f5f4dd1076f9569db42aa9f0f27127a6f0d68009","size":"4MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ae103f89c84644ff9172375f2aa2c907","version":"ae1a27ea06534fe2aac8db60eb71132d"},"installation":{"command":"CP040114.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-08T14:50:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SLES15SP1.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4766374","datemodified":"2020-12-13T15:11:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/CP045455.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/TAPM4VVEHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045455.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045455.scexe"],"md5sum":"330bbd61ebaa3fcb696232418581cc7e","name":"firmware-hdd-b8a60fbe9a-HPD5-4.1.x86_64.rpm","release":"2020-12-13T14:58:04","revision":"0","sha1sum":"e5c519ffb4c9fc1025c9db0e16db79a0212833aa","size":"4MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0621549b347544c1869a7fcad2fb7ecf","version":"4c9ecaf65e7245ae8ecbe7fabc3717f5"},"installation":{"command":"CP041423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000GWRTCドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for WIndows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4149272","datemodified":"2020-12-17T05:49:47","file_list":["cp045525.xml","cpqsetup.exe","HVLPeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"ab6fab698473c08809b029a34f631f96","name":"cp045525.exe","release":"2020-12-17T05:41:04","revision":"0","sha1sum":"bcc2b84bb41d629237d1588be8a377406fab59c3","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"92d9bf17d9ef471e842a80e42a41ec72","version":"988ae7a0263b4228aa88a91308d6d6f6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:41:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYYV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5526873","datemodified":"2020-12-13T13:59:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/CP045444.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/SMPN6SD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045444.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045444.scexe"],"md5sum":"16582def8fe95017e366a0db20811ae9","name":"firmware-hdd-0595c2a887-HPD2-7.1.x86_64.rpm","release":"2020-12-13T13:46:29","revision":"0","sha1sum":"190d9b699b72a0c5d3250757cf7ccaca66d3d340","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"2dc381cd01314b3ba2f24f5b5647b2a3","version":"ef41b322758e4a27b4a0b506d48f9ac4"},"installation":{"command":"CP040307.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 7.0"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"900778","datemodified":"2020-11-20T08:43:34","file_list":["/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip","/cp044792.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/doc/README.txt","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_4.1.22.0-1OEM.700.1.0.15843807.vib","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/vibs/qlnativefc--1613597594131483861.xml","/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862-package.zip/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807_17189862.zip/metadata.zip/bulletins/MRVL-QLogic-FC_4.1.22.0-1OEM.700.1.0.15843807.xml"],"md5sum":"9d2822c7142a2268b58f566f14723201","name":"cp044792.zip","release":"2020-11-20T08:42:25","revision":"0","sha1sum":"062772b4cda2b507e7e2b23d6e62667c89912d46","size":"879KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"4.1.22.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"c1a4b1e8f3024c9bbd04b1730ba98308","version":"4d188211bbb448c897b71a78c7d7b53a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:30:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Driver version 4.1.9.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Driver version 4.1.22.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qlnativefc:4.1.22.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-QLogic-FC:4.1.22.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Smart Array SAS/SATA Event Notification Service provides event notification to the 64-bit Microsoft Windows Server 2012, 2012 R2, 2016, and 2019 editions system event log and the HPE ProLiant Integrated Management Log for systems using the HPE Smart Array SAS/SATA controller driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"663152","datemodified":"2018-09-12T01:13:28","file_list":["cissesrv.dll","cissesrv.exe","cissesrv.msi","cp037465.xml","cpqsetup.exe"],"md5sum":"bf339ceb1536ea7a248fceb54892dd0e","name":"cp037465.exe","release":"2018-09-12T06:12:04","revision":"0","sha1sum":"647f57a28fcfa7a547bb039566ed4fdc07ff6c3a","size":"647KB","target_guids":[],"type_of_change":"0","version":"6.46.0.64"}],"id":{"product":"C9019","version":"e52301c0ca104cbb9bbb531d56bc60b3"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array SAS/SATA Controller Driver","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b896bf","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Smart Array SAS/SATA Controller Driver"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Smart Array HPCISSS3 Controller Driver for Windows Server"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Embedded G6 SATA RAID Controller Driver for Microsoft Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfe76aead","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Embedded G6 SATA RAID Controller Driver for Microsoft Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5165615f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec98fcf239","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Dynamic Smart Array RAID Controller Driver for Windows Server"}]}]}]},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為自我解壓縮的可執行檔，其檔名包含智慧型元件編號。<br><p>從該磁碟和目錄，執行下載的檔案。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다.<br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다."},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。<br><p>在该硬盘目录中，执行下载的文件。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array SAS/SATA Event Notification Service for 64-bit Windows Server Editions"},{"lang":"ja","x_late":"64-bit Windows Server Editions用HPE ProLiant Smartアレイ SAS/SATA Event Notification Service"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3233","subdev":"3233","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-09-27T07:12:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Microsoft Windows 10</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Windows Server 2019 OS.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"cissesrv.exe","sw_key_expectedpath":"%programfiles%\\hp\\cissesrv"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.42.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.42"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3942601","datemodified":"2020-12-17T07:04:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/CP042871.xml","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/UBM1_V1.42.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-2e20068436-1.42-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP042871.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP042871.scexe"],"md5sum":"f07148ddc1655417971a2101aeecf8a3","name":"firmware-2e20068436-1.42-1.1.x86_64.rpm","release":"2020-12-17T06:41:12","revision":"0","sha1sum":"5ff760c30ab7ea5e317c2de502ebff8e70fd2014","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.42"}],"id":{"product":"314bc817543f4e91a4b234b38c27ef87","version":"b21dfbf954924d1fa299076689ba5b27"},"installation":{"command":"CP042871.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP042871.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-2e20068436-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP042871.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-2e20068436-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-2e20068436-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-smartarray-2e20068436-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM1 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-02T08:39:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"594262","datemodified":"2021-01-28T09:31:08","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-193.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"34baccff91fd03b78fdd9065bdf3583b","name":"kmod-elx-lpfc-12.8.352.11-1.rhel8u2.x86_64.rpm","release":"2021-01-28T09:21:20","revision":"0","sha1sum":"147a873fd945b4a86431ce1a7a47f9a12613cdfd","size":"580KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"2e58b72d90ee4595851925dd371b1254","version":"605c8f1ac38e48f3b9763efa2cab086b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 2 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"ja","x_late":"ドライバ - ビデオ"},{"lang":"cn","x_late":"驱动程序 - 视频"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eH3ビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"1604360","datemodified":"2020-06-05T07:52:04","file_list":["cp041584.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"md5sum":"2954a742d168c734fd9593abb2b451dc","name":"cp041584.exe","release":"2021-04-22T00:00:00","revision":"1","sha1sum":"c4be2baa1a7b6c7bf1f4157231636a8284753e4a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"f74d68169f04405fb74a2820e48df6f5","version":"b1e7c8c9edab4a7da9fc17755693a3c5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Matrox G200eH3 Video Controller Driver for Microsoft Windows Server 2016 and Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0538","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-0538159000e4","type":"pci","ven":"102B"},{"dev":"0538","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-05381590027f","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-23T15:29:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>TBD</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Intel ICX platforms</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEXXV Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GEXXVドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5220000","datemodified":"2020-12-13T13:57:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/CP045440.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/TTMRETG2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045440.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045440.scexe"],"md5sum":"f6c5839be2877837fe63ed61fdc3694c","name":"firmware-hdd-a629fcea59-HPG2-9.1.x86_64.rpm","release":"2020-12-13T13:46:32","revision":"0","sha1sum":"ce7f986d4becffc5460f54176442f3289a91606a","size":"4MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"0514481c6d244017bb9549a474c6c48c","version":"a7d0602bb7c346adb517ab49c5767a87"},"installation":{"command":"CP040292.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG1"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG1"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG1"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"9226034","datemodified":"2020-12-13T16:13:32","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/CP045473.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/K503HPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG1-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045473.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045473.scexe"],"md5sum":"e399608351e34cf780917da78e33fa65","name":"firmware-hdd-8e1e8083c5-HPG1-3.1.x86_64.rpm","release":"2020-12-13T16:01:17","revision":"0","sha1sum":"6e92d7d3b78c2422d140f64ce55556fce069efb7","size":"8MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"24bbe0adc4dc4c7385b6f5ad6aecf867","version":"9bc85f4b08f741c595a3d9d8133dab70"},"installation":{"command":"CP043280.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:20:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34203920","datemodified":"2021-02-25T12:41:49","file_list":["A47_2.40_02_23_2021.signed.flash","cp046228.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"74c2fe080ee1afcdeece10c925a12b96","name":"cp046228.exe","release":"2021-02-25T12:40:05","revision":"0","sha1sum":"800fb79d4b38ef19fd7572377f1b2e649df61f2c","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"0","version":"2.40_02-23-2021"}],"id":{"product":"f25420df1f7142d3a5eccbf213f27251","version":"f1668619537d4ff7b387fd9916b1336f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-04T22:33:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support for Direct Liquid Cooling solution.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>HPE ProLiant XL675d Gen10Plus CPLD version 0F<p>HPE Apollo 6500 Gen10 Plus Chassis CPLD version 0909<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE, and EO0800JEFPF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5208459","datemodified":"2020-12-13T15:15:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/CP045456.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/HSSCPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045456.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045456.scexe"],"md5sum":"8392f2393c73c9121614e8cb0f5d41d2","name":"firmware-hdd-71af849f3b-HPD3-7.1.x86_64.rpm","release":"2020-12-13T15:01:29","revision":"0","sha1sum":"b777127ec458c26509be0cff8bd5d5b1f83ce2ca","size":"4MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5691df43dd354d538b509faabb482ba9","version":"f7a87dbcb5aa4650afc2f146ef6bda5a"},"installation":{"command":"CP040260.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.08-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.08"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"可升级 HPE ProLiant Gen9 扩展卡上机柜固件的补充更新/在线 ROM Flash 智能组件"},{"lang":"tw","x_late":"補充更新/線上 ROM 更新智慧型元件，可升級 HPE ProLiant Gen9 擴充的機櫃韌體"},{"lang":"ko","x_late":"추가 업데이트/HPE 프로라이언트 Gen9 확장기에서 인클로저 펌웨어를 업그레이드하는 온라인 ROM 플래시 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n<strong>&nbsp; &nbsp; &nbsp;</strong>Online ROM Flash Component for Linux &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.08<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.93<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4.93<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Added support for UBM backplanes</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5390145","datemodified":"2021-01-28T14:38:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/CP044963.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/firmware-Signed-5.08-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-5.08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044963.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044963.scexe"],"md5sum":"372beb5da5555290a61265dac227a02c","name":"firmware-smartarray-2de15b6882-5.08-1.1.x86_64.rpm","release":"2021-01-28T14:23:07","revision":"0","sha1sum":"3ac3fc02630c449c74cf7156b7070b3fb8532560","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.08"}],"id":{"product":"799e6d2dd6574724a67dc3ea392d2873","version":"495fe3b67523462ea6ad0e7e7094713c"},"installation":{"command":"CP044963.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle/ cold reboot is required if firmware is upgraded from version 1.31 or earlier.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044963.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP044963.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 – 适用于HPE智能阵列控制器和HPE HBA控制器的HPE 12Gb/s SAS扩展器固件"},{"lang":"tw","x_late":"適用於 Linux (64) 的補充更新/線上 ROM 更新元件 – 適用於 HPE Smart Array 控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 擴充韌體"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS 익스팬더 펌웨어"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE 12 Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-21T15:31:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue where false Smart Carrier authenication errors may happen.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Gen10 plus UBM type 1/2/3 backplanes</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Smart Carrier Authentication Failure issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027088","datemodified":"2021-01-08T18:15:53","file_list":["cp046115.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"bc7670e43486949a772e857b86bdd582","name":"cp046115.exe","release":"2021-01-08T18:02:04","revision":"0","sha1sum":"cb20e39880950287825851cb87fbf1379caf5224","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"7a38c76de8ff4383970907d2998b1740","version":"93e6920214dc4919bd95c3a400c54ef8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated .cat file.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1442248","datemodified":"2021-01-09T07:55:37","file_list":["cp045011.xml","cpqsetup.exe","cp_data.xml","iavf65.cat","iavf65.din","iavf65.inf","iavf65.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"cea7da9999e8eb9b24eea21fc4ed6428","name":"cp045011.exe","release":"2021-01-09T07:37:04","revision":"0","sha1sum":"96e18c5bee40225ff648f733e4148921304a6aaf","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc729bb39"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"d480f616863140bd906bb9e3934e35ae","version":"51c863ae26a042a3bf499fe0420670f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"iavf65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD5"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR and EG002400JWJNT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>       None</p>\n\n<p><strong>Known Issues:</strong><br />\n       None</p>"}],"files":[{"bytes":"4234192","datemodified":"2020-12-17T13:30:18","file_list":["cp045496.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ED5.rel"],"md5sum":"fb3d283e050cd2da505e4154fb70d61c","name":"cp045496.exe","release":"2020-12-17T13:22:09","revision":"0","sha1sum":"25c2f5076a3b74d3d8c1808839c3618266f3e57e","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"17b00802f88a41f591cee6102caaf9d2","version":"3d2acc7394004ccda4a789d53518b2dd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR and EG002400JWJNT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:30:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0111"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"36285732","datemodified":"2021-01-21T14:45:57","file_list":["/CP046455_BUILD_3.data","/CP046455.vmcfg","/CP046455.vmexe","/CP046455.vmexe64","/CP046455.vmfile","/CP046455_VMw.zip","/CP046455.xml","/payload.json","/CP046455_VMw.zip/index.xml","/CP046455_VMw.zip/vendor-index.xml","/CP046455_VMw.zip/metadata.zip","/CP046455_VMw.zip/vib20/CP046455/HPE_bootbank_CP046455_0111.3-7.0.0.15525992.vib","/CP046455_VMw.zip/metadata.zip/vendor-index.xml","/CP046455_VMw.zip/metadata.zip/vmware.xml","/CP046455_VMw.zip/metadata.zip/vibs/CP046455--3341691222451485446.xml","/CP046455_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046455_0111.3-7.0.0.15525992.xml"],"md5sum":"46ddaa9a4a4adb3bef604a9f4928778d","name":"CP046455.zip","release":"2021-01-21T14:41:05","revision":"0","sha1sum":"f060c272ca0233e6509676ce9bf6dc418010ca7f","size":"34MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0111","vib_list":[{"name":"CP046455","version":"0111.3-7.0.0.15525992"}]}],"id":{"product":"d65fb45f0327449eb7763d2d9cb7bf3e","version":"3f8b0c0979f34c98a460fa7fac372974"},"installation":{"command":"setup","command_params":"-t D8000 -v 0111 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2019.35.0.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2019.35.0.gff -l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"HPE D8000 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-16T04:34:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>In STD INQUIRY RESPONSE, the ErrM bit was always being set. The ErrM bit indicates that the enclosure firmware detects a mismatch in any of its package versions and the firmware version of a FRU component. The issue was due to an incorrect version of PSU firmware being included and that has been fixed.</p>\n\t</li>\n\t<li>\n\t<p>After installing the latest firmware on the enclosure I/O modules, the SES targets could not be discovered on the host. The virtual phy bit in SMP DISCOVER RESPONSE, which is used by the Microchip smartpqi HBA, was det for the virtual phy of the I/O module.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v183134/D8000_P20366-004.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Incorrect programming of the&nbsp;PHY ERROR COUNTERS parameter caused the amber LED to be lit, resulting in a false warning. The counter condition was corrected and the amber LED now functions correctly.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v191365/D8000_v0111.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&bull;&nbsp;&nbsp; Added support for RHEL 8.3</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None&nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4637233","datemodified":"2020-12-13T15:18:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/CP045291.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/GP863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045291.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045291.scexe"],"md5sum":"59cfc13e3719d60ed36b2deaae1ca560","name":"firmware-hdd-f42438de3d-HPG3-6.1.x86_64.rpm","release":"2020-12-13T15:06:05","revision":"0","sha1sum":"0901ea3d0a0cb737aeb9d674e077525d16e0e533","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"dee0352e8d5a4157b5757fd1a1669bb8","version":"7c8ac296a0a34a4a8db7d8cb67c6e987"},"installation":{"command":"CP040346.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-18T15:35:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 (64-bit) to enable the HPE H2xx SAS/SATA Host Bus Adapter.  This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE H2xx SAS/SATAホストバスアダプターを有効にする、SRed Hat Enterprise Linux 7（64-bit）用のビルド済みバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1147503","datemodified":"2018-12-10T07:23:59","file_list":["./etc/modules-load.d/mpt2sas.conf","./lib/modules/3.10.0-862.el7.x86_64","./lib/modules/3.10.0-862.el7.x86_64/extra","./lib/modules/3.10.0-862.el7.x86_64/extra/mpt2sas","./lib/modules/3.10.0-862.el7.x86_64/extra/mpt2sas/mpt2sas.ko","./usr/share/smartupdate/kmod-mpt2sas/component.xml"],"md5sum":"f76ed51dbeac4a6d5fbd31ec0fb8ebca","name":"kmod-mpt2sas-15.10.07.00-3.rhel7u5.x86_64.rpm","release":"2018-12-10T07:24:03","revision":"0","sha1sum":"c394c206e1e9a7c2b4f2240f560523a8ed6d94e0","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-2"},{"bytes":"1156070","datemodified":"2018-12-10T07:25:11","file_list":["./etc/modules-load.d/mpt2sas.conf","./lib/modules/3.10.0-957.el7.x86_64","./lib/modules/3.10.0-957.el7.x86_64/extra","./lib/modules/3.10.0-957.el7.x86_64/extra/mpt2sas","./lib/modules/3.10.0-957.el7.x86_64/extra/mpt2sas/mpt2sas.ko","./usr/share/smartupdate/kmod-mpt2sas/component.xml"],"md5sum":"65efdaf812e018d497c99171a3ffba76","name":"kmod-mpt2sas-15.10.09.00-2.rhel7u6.x86_64.rpm","release":"2018-12-10T07:24:03","revision":"0","sha1sum":"06ef9853199aa335bc3d87052f01ed24a6acaa63","size":"1MB","target_guids":[],"type_of_change":"1","version":"15.10.09.00-2"}],"id":{"product":"528278d2176f4aa5b24b63a8f09b5e95","version":"01a85020813547fb9aed828bab315132"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-x represents the version number and N represents the OS Update number)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-x represents the version number)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n\n<p>Note: If HPE System Insight Manager support is required, install the latest ProLiant Support Pack and kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm after the OS has completed its installation process and system has rebooted.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpm (x.x.x.x-xはバージョン番号を、NはOSアップデート番号を表します。)<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-mpt2sas-X.X.X.X-X.rhel7xx.x86_64.rpm (x.x.x.x-xはバージョン番号を表します。)</p>\n\n<p>セットアップが完了したらコンピュータをリブートする必要があります。</p>\n\n<p>注: HPE System Insight Managerのサポートが必要な場合、OSのインストールが完了してシステムがリブートした後で、ProLiant用の最新のサービスパックとkmod-mpt2sas-X.X.X.X-X.rhel7uN.x86_64.rpmをインストールします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE H2xx SAS/SATAバスアダプタードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0070","subdev":"0046","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0044","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0043","subven":"1590","target_guid":"","type":"pci","ven":"1000"},{"dev":"0087","subdev":"0041","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-03T09:25:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Address the Linux Spectre Variant 2 Vulnerability Issue</p>\n"},{"curr_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 7 Update 6</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P81","value":"HP ProLiant DL380p Gen8 SE Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"}],"sw_keys":[{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mpt2sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure firmware on the HPE Apollo 45xx Gen9 Backplane Expanders"},{"lang":"cn","x_late":"更新HPE Apollo 45xx Gen9背板扩展卡机箱固件的在线智能组件"},{"lang":"tw","x_late":"可升級 HPE Apollo 45xx Gen9 背板擴充卡上機櫃韌體的線上智慧型元件"},{"lang":"ko","x_late":"HPE Apollo 45xx Gen9 백플레인 익스팬더에서 인클로저 펌웨어를 업그레이드하는 온라인 스마트 구성요소"},{"lang":"ja","x_late":"HPE Apollo 45xx Gen9バックプレーンエキスパンダー上のエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 45xx Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50 (A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.50<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;2.50<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;Expander may reset during heavy SSACLI polling</li>\n\t<li>SATA drives may take longer to spin up, not be initially detected, and then hot add later. This can prevent system boot or affect the logical drive status.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22067183","datemodified":"2020-08-28T03:23:43","file_list":["/CP045346.vmexe","/CP045346.vmexe64","/CP045346.vmfile","/CP045346.xml","/payload.json","/README.txt"],"md5sum":"b1578ff4f4ca2339b0dd91a0ffe8eef3","name":"CP045346.zip","release":"2020-08-28T03:10:05","revision":"0","sha1sum":"1bc7a76f060c077164106e2ed590567c3f47672a","size":"21MB","target_guids":[],"type_of_change":"1","version":"2.50","vib_list":[]}],"id":{"product":"21e4b5b75bfd4055af20a7109d8d2e08","version":"3966abc47825421d85bbc0c02ee6f20c"},"installation":{"command":"CP045346.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Please&nbsp;un-plug and re-plug the power cord to the server for firmware upgrade from version 1.03&nbsp;or earlier to take effect.&nbsp;</u></p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 45xx Gen9 Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-24T10:50:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for the ESXi OS 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for the ESXi OS 7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"HP Apollo 4530","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4520","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"HP Apollo 4510","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PICGen10_1.0.7s.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.7"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"666336","datemodified":"2021-01-15T07:55:30","file_list":["cp046568.xml","cpqsetup.exe","LICENSE.txt","payload.json","PICGen10_1.0.7s.hex","SecureFlash64.dll"],"md5sum":"59a9d78b349be3856db6fbce806592da","name":"cp046568.exe","release":"2021-01-15T07:53:05","revision":"0","sha1sum":"58b76c6cf7fa86097aea5a034d669ec1d222b71c","size":"650KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.7"}],"id":{"product":"b81956d2c370432aad5ffc0ea6fc40b3","version":"2f386f4af4224f9f916c7193874cc4ca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p>This component can only be executed on Windows x64.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するために[インストール]ボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br/>\n </p>\n\n<p>このコンポーネントは、Windows x64上でのみ実行できます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-15T07:48:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.7 (B) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7.  It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.<br>&nbsp;<P><B>Firmware Dependencies:</B></P>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.<P><B>Enhancements/New Features:</B></P>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors.   iLO5 version 1.40 or above is required to upgrade to this version.<p>This is the initial version for HPE Gen10 Plus servers.<P><B>Known Issues:</B></P>None","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (D) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (D) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.<br />\n&nbsp;</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6277038","datemodified":"2021-01-08T13:56:01","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/bnx2.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2fc.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2i.ko","./lib/modules/4.12.14-94.41-default/updates/bnx2x.ko","./lib/modules/4.12.14-94.41-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"1b3c67ba4cecb4508eac6b98c11eca6c","name":"netxtreme2-kmp-default-7.14.76_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-08T13:28:05","revision":"0","sha1sum":"23c89dc687770945436f9bd5ba7df35f336515f2","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"6392809","datemodified":"2021-01-08T13:51:39","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"b7f6957c242b8e9083f2706c2fa95f61","name":"netxtreme2-kmp-default-7.14.76_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-08T13:28:05","revision":"0","sha1sum":"520fe259ab81737b9f7c738c599ab68a03d9bcce","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"4cbf7b1f2fb64da880e8ed0ed8c83095","version":"6a7a88e0b9754853be953b3b8bf4bc6c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the driver Precision Time Protocol (PTP) is not working due to timestamp problem.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE HBA(Host Bus Adapters) H221"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 HPE HBA（ホストバスアダプター）H221"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) HPE Host Bus Adapters&nbsp;H221</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (E)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 15.10.10.00 (D)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp;Improved Integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong>&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3061848","datemodified":"2018-12-13T08:40:55","file_list":["cp038049.xml","cpqsetup.exe","firmware.cfg","H210i_it.fw","H220i_it.fw","H220_it.fw","H221_it.fw","H222_it.fw","InstallDll.dll","mptsas2.rom","sas2flash.exe"],"md5sum":"66fb17f361e0d801067ca13665b87873","name":"cp038049.exe","release":"2018-12-13T14:39:03","revision":"0","sha1sum":"b7207de055f0e7d1b1d26f8ca67e97a346726a70","size":"2MB","target_guids":[],"type_of_change":"0","version":"15.10.10.00"}],"id":{"product":"defe118a27e24cc9962950a6158c3e89","version":"8519df5231bc487cb2e0ce94c464ab39"},"installation":{"command":"cpqsetup.exe","command_params":"/t \"H220i\" /t \"H220\" /t \"H222\" /t \"H210i\" /t \"H221\" /c","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Host Bus Adapters H221"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPEホストバスアダプターH221"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-02T07:37:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"00441590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00461590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00411590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00431590","sw_key_expectedpath":"firmware:sd:hba"},{"name":"00421590","sw_key_expectedpath":"firmware:sd:hba"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<br type=\"_moz\" />\n"}],"files":[{"bytes":"6989796","datemodified":"2020-11-04T22:36:34","file_list":["/CP046170.vmexe","/CP046170.vmfile","/CP046170.xml","/README.txt"],"md5sum":"caf1f0518c0586a52f16870c216c7e27","name":"CP046170.zip","release":"2020-11-05T04:34:05","revision":"0","sha1sum":"77129e04748e7917d712faa3f79d69bc6fca1be4","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"c4fb9c8ca4c44e82816b0b0a69f77b80","version":"929b23682d5b48c88d61c905649fd58e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL60 Gen9/DL80 Gen9 (U15) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant DL60 Gen9/DL80 Gen9（U15）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T07:16:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"}],"sw_keys":[{"name":"U15","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"17680","datemodified":"2021-02-09T15:23:23","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"4fe2c8bf75c204891a63edb32462e494","name":"kmod-kernel-mft-mlnx-4.16.0-1.rhel7u8.x86_64.rpm","release":"2021-02-09T15:11:04","revision":"0","sha1sum":"adca51b3dcc1eede63bdf671b28cf26aab42b3f6","size":"17KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"},{"bytes":"8915482","datemodified":"2021-02-09T15:26:07","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"1f6a89be7eca7daa8a6ec194572c4c85","name":"mft-4.16.0-105.rhel7u8.x86_64.rpm","release":"2021-02-09T15:11:04","revision":"0","sha1sum":"af2ca34e2ce3cd4e68a635d2b590fceccd288201","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.16"}],"id":{"product":"d626ca1e86a84798ad6a218e046f62c6","version":"57fa825d180d4a1eb87689b06d97fbd3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.16.0-1.rhel7u8.x86_64.rpm mft-4.16.0-105.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.42_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.42 (02/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33581765","datemodified":"2021-02-25T11:50:51","file_list":["A46_2.42_02_23_2021.signed.flash","A46_2.42_02_23_2021.xml","payload.json"],"md5sum":"8716f3b9feb1cb51ab753355f4be4fcd","name":"A46_2.42_02_23_2021.fwpkg","release":"2021-02-25T11:47:06","revision":"0","sha1sum":"b143490768da462872b8d1011cba6605e9843c39","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"1","version":"2.42_02-23-2021"}],"id":{"product":"17ae190412f049ff80b7f941eb9e3732","version":"ae60987bc484485fa540d44eafa730ad"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-22T17:17:49","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed an issue where the chassis name was not being reported for inventory control.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>System Programable Logic CPLD version 34<P><B>Problems Fixed:</B></P>Addressed an issue that could cause a slight degradation of performance.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596829","datemodified":"2021-01-27T20:17:31","file_list":["payload.json","U38_2.42_01_23_2021.signed.flash","U38_2.42_01_23_2021.xml"],"md5sum":"d692ca48a8e1ec3caf625cc633176c96","name":"U38_2.42_01_23_2021.fwpkg","release":"2021-01-27T20:08:05","revision":"0","sha1sum":"5efd46b73f69aa102890b7444e6121103054ce84","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"703e98acf33d484a9d2825573e86e8c0","version":"ef681d3e0afd4c7f80967265d19c0471"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T20:47:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800100","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置"},{"lang":"en","x_late":"Software - Storage"},{"lang":"ko","x_late":"소프트웨어 - 스토리지"},{"lang":"ja","x_late":"ソフトウェア - ストレージ"},{"lang":"cn","x_late":"软件 - 存储"}]}],"description":[{"lang":"en","x_late":"The Host Explorer communicates with the HPE 3PAR StoreServ system over an FC or iSCSI connection and enables the host to send detailed host configuration information to the HPE 3PAR StoreServ System. The information gathered from the Host Explorer is visible for uncreated hosts and assists with host creation and diagnosing host connectivity issues. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1682304","datemodified":"2018-02-09T04:43:11","file_list":["cp034831.xml","cpqsetup.exe","hesetup.exe","HostExplorer-win2k12-3.2.1-0.x64.msi","HostExplorer-win2k16-3.2.1-0.x64.msi","HostExplorer-windows-3.2.1-0.x64.msi"],"md5sum":"6eaa3327221828d012b3872f674a5886","name":"cp034831.exe","release":"2018-02-09T04:08:03","revision":"0","sha1sum":"2129fd8429cb944a74b72b0d43e0f8c58b9db057","size":"1MB","target_guids":[],"type_of_change":"1","version":"3.2.1.0"}],"id":{"product":"d2758fac106e4fcd86a4e9b65fdf0119","version":"7c9e3001602d47ada84aad1f7ba11fd2"},"installation":{"command":"hesetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the smart component&nbsp;to host machine and run the smart component.</p>\n\n<p>HPE 3PAR HostExplorer smart component will be installed only if the host has connectivity&nbsp;to HPE&nbsp;3PAR StoreServ.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE 3PAR HostExplorer for Windows Server 2008 2012 and 2016 x64 Operating Systems"},{"lang":"ja","x_late":"Windows Server 2008 2012および2016 x64オペレーティング システム用のHPE 3PAR HostExplorer"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"core","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Core Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"ebs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Essential Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Small Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-03-07T06:35:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>&nbsp;Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>&nbsp;Support for Windows server 2016</li>\n</ul>\n","latest_fixes_x_late":"<p>The following issues are&nbsp;fixed for HPE 3PAR Host Explorer 3.2.0 release:&nbsp;</p>\n\n<ul>\n\t<li>&nbsp;IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>Support for Windows server 2016</li>\n\t<li>HPE 3PAR Host Explorer Windows supports upgrade to 3.2.1.</li>\n\t<li>HPE 3PAR OS version compatibility check in HPE 3PAR Host Explorer</li>\n</ul>\n","curr_fixes_x_late":"<p>The following are the issues fixed in HPE 3PAR Host Explorer 3.2.1 release:</p>\n\n<ul>\n\t<li>IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8-GHz 16GB Control/32GB Data Cache Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rackmount Config Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Upgr Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10800 2.8-GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 3PAR 2.8-GHz 32GB Control/64GB Data Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base for Storage Centric Rack"}],"sw_keys":[{"name":"TpdHostAgent.exe","sw_key_expectedpath":"%PROGRAMFILES%\\Host Explorer"},{"name":"3PAR Host Explorer","sw_key_expectedpath":"software:sd:3parhostexplorer"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:VO1920JEUQQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：VO1920JEUQQのファームウェアを提供します"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5184009","datemodified":"2020-12-13T15:54:05","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/CP045468.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/HSCPPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045468.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045468.scexe"],"md5sum":"637021283d83c6c71d9bc0b1df4af297","name":"firmware-hdd-5d9e841607-HPD3-7.1.x86_64.rpm","release":"2020-12-13T15:42:05","revision":"0","sha1sum":"6824b6717b3d89608c5ebc856dce27f98c062ef1","size":"4MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c979876c84d42aba65fe31d9aa00e1f","version":"db93c053ee854774828aa1aeedf8f679"},"installation":{"command":"CP040312.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGE"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGE"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGE"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGE"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGE"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGE"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5006633","datemodified":"2020-12-13T15:16:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/CP045457.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/M5100MGE.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGE-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045457.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045457.scexe"],"md5sum":"d74a5a1526b68cc30a7aad2579f78a28","name":"firmware-hdd-9196d4f720-HPGE-4.1.x86_64.rpm","release":"2020-12-13T15:04:05","revision":"0","sha1sum":"cae104787c4cc0eb7d407f217c9e88b1092719e7","size":"4MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGE"}],"id":{"product":"a6840b5d0ec24ee78bf7a78ec26db476","version":"ccce75171f554f2183b302975bb25606"},"installation":{"command":"CP041316.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD7"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD7"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG0600JETKA, EG0900JETKB, and EG1200JETKC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：EG0600JETKA、EG0900JETKB、およびEG1200JETKC対応のファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"2902328","datemodified":"2020-12-17T13:04:16","file_list":["cp045499.xml","cpqsetup.exe","payload.json","setup.dll","TA14SED7.REL"],"md5sum":"d049754e0632d48cdf1e69812fa5f6b5","name":"cp045499.exe","release":"2020-12-17T12:56:10","revision":"0","sha1sum":"c00d228183b610d07b0e93de03a5b66513315401","size":"2MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"696ee1f3634445c49a160d3bc3772307","version":"6dc5b5e2990d48ebae2fcbf729e0601b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:32:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB002000GWFGH and MB001000GWFGF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB002000GWFGH および MB001000GWFGF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16724689","datemodified":"2021-01-27T21:46:43","file_list":["/CP045629_BUILD_3.data","/CP045629.vmexe","/CP045629.vmexe64","/CP045629.vmfile","/CP045629_VMw.zip","/CP045629.xml","/payload.json","/CP045629_VMw.zip/index.xml","/CP045629_VMw.zip/vendor-index.xml","/CP045629_VMw.zip/metadata.zip","/CP045629_VMw.zip/vib20/CP045629/HPE_bootbank_CP045629_HPG3.3-7.0.0.15843807.vib","/CP045629_VMw.zip/metadata.zip/vendor-index.xml","/CP045629_VMw.zip/metadata.zip/vmware.xml","/CP045629_VMw.zip/metadata.zip/vibs/CP045629--4413085880266300933.xml","/CP045629_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045629_HPG3.3-7.0.0.15843807.xml"],"md5sum":"0f61f64ed0641f290aae7532e7615f24","name":"CP045629.zip","release":"2021-01-27T21:44:05","revision":"0","sha1sum":"21f71d5607681ec8bbcb244c827209a94fd09887","size":"15MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3","vib_list":[{"name":"CP045629","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"38555f7d1f134877a75c17953659a8a3","version":"334832c847f0431b9e08c491f71d87ff"},"installation":{"command":"CP040652.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"},{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:33:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander "},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; Apollo 2000 System -&nbsp;SAS Expander</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.52(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.52<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.52<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>Fixed an issue in the HPE Apollo 2000 System SAS Expander FW where the HDD Zoning Table would be set to default after upgrading to 1.51</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"21967457","datemodified":"2020-08-28T03:32:31","file_list":["/CP045347.vmexe","/CP045347.vmexe64","/CP045347.vmfile","/CP045347.xml","/payload.json","/README.txt"],"md5sum":"3d0477976e96b81f4ce8f078426b3063","name":"CP045347.zip","release":"2020-08-28T03:12:05","revision":"0","sha1sum":"1d7f81ef8f7c73d9d036edfb0ba23c947b8aa63e","size":"20MB","target_guids":[],"type_of_change":"1","version":"1.52","vib_list":[]}],"id":{"product":"05a973be660c403e96be2ba6f872a56d","version":"8ad5f719318c4ddaa9df7476d58a4be3"},"installation":{"command":"CP045347.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n\n<p><strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 System - SAS Expander"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-24T10:54:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for Windows Server 2019</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3645896","datemodified":"2020-12-11T19:26:37","file_list":["cp045899.xml","cpqsetup.exe","payload.json","SCIMARRNNTG3.rel","setup.dll"],"md5sum":"fc66c30a98c10d75bef8c3bab5281707","name":"cp045899.exe","release":"2020-12-11T19:18:05","revision":"0","sha1sum":"94d817e579d111f2aac35e32c167ede23ce9e65f","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"260b73b77b824e60a7231a400ce24c25","version":"71e482c82f79498b8444f1dbbfee2a97"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T12:03:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD8"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4856084","datemodified":"2020-12-16T09:22:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/CP046241.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/TAMG06scHPD8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD8-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046241.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046241.scexe"],"md5sum":"468f3b1f99971d4248766227a2144c9e","name":"firmware-hdd-faf39e0ff7-HPD8-1.1.x86_64.rpm","release":"2020-12-16T09:08:08","revision":"0","sha1sum":"50fc619448b256471801502f7cb4a3fe6d85e865","size":"4MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"fcf6b49416e1460393e2103c04483878","version":"9b798a91620e450b835fa17491d00c6d"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000JWJRQおよびMB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-05T15:56:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"185480","datemodified":"2021-03-08T18:12:51","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"2ff12504be520429eeeb39482a07ed65","name":"kmod-hp-ixgbe_bl-5.9.4-2.rhel8u3.x86_64.rpm","release":"2021-03-08T18:04:05","revision":"0","sha1sum":"19bbb279baea39481dfbdf7753de8ec26fc33dd9","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"185317","datemodified":"2021-03-08T18:11:50","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"84b0cc8b12575a24f616440fb291039a","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel8u2.x86_64.rpm","release":"2021-03-08T18:04:05","revision":"0","sha1sum":"f2dad3c88cf0832239cefcc3a5124b0d561b3911","size":"180KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"6a2763c5a8ec446e809e71991d4253f9","version":"53acdfd16b834b32afb029bddf01ef03"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1638971","datemodified":"2021-01-27T10:26:46","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"c9b4fa11f147c024c84b67650655769b","name":"mlnx-ofa_kernel-kmp-default-5.2_k5.3.18_22-OFED.5.2.1.0.4.1.sles15sp2.x86_64.rpm","release":"2021-01-27T08:57:06","revision":"0","sha1sum":"b205cc1fa5c85c1ecad933aacef05029d16cb3e9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1331962","datemodified":"2021-01-27T10:28:45","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/rdma-set-sriov-vf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.2.2","./usr/share/doc/packages/libvma-9.2.2/README.txt","./usr/share/doc/packages/libvma-9.2.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.2.2/journal.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"9e362aa42a0c797b319ac7ace5cc628c","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles15sp2.x86_64.rpm","release":"2021-01-27T08:57:06","revision":"0","sha1sum":"587eb656e741922a473b368e20dc6e6fe1be4f3b","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"725f060c9eaa4196aa47bcf7495820ec","version":"e6d966b79ec84c6a9f01d1cf8d01107b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.sles15sp2.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.2_k5.3.18_22-OFED.5.2.1.0.4.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_2p24_PLDMoMCTP_800059DB.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"2.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td>\n\t\t\t<td>800059DB</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>2.24</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2839.0 includes: Intel(R) Boot Agent ICE v2.2.01 &amp; UEFI x64 100 gigabit driver v2.2.07.</p>\n"}],"files":[{"bytes":"10516620","datemodified":"2021-01-21T10:48:56","file_list":["HPE_E810_CQDA2_2p24_PLDMoMCTP_800059DB.HPb","HPE_E810_CQDA2_2p24_PLDMoMCTP_800059DB.xml","payload.json"],"md5sum":"c290876a30ebe139b49be6a7aa35f1bb","name":"HPE_E810_CQDA2_2p24_PLDMoMCTP_800059DB.fwpkg","release":"2021-01-21T10:44:11","revision":"0","sha1sum":"bb993f5081f91ccb902970fed18fe79392d3ae12","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159280860002"],"type_of_change":"1","version":"2.24"}],"id":{"product":"f3f8a4081d78499e9a2dd9c8d9fb4059","version":"b38916a6d91c4bc3982115ad94bbc38b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"INTEL_E810_CQ2_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPE Service Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"34466461","datemodified":"2021-01-28T15:10:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/CP046216.xml","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives/hpoa350.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oa497.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade32","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade64","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046216.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046216.scexe"],"md5sum":"7e9e77475f20a1849957d8e789fd5135","name":"firmware-oa-4.97-1.1.x86_64.rpm","release":"2021-01-28T14:59:07","revision":"0","sha1sum":"faa394574186f2d488dd1b78b4caf4174486511d","size":"32MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"C9506","version":"71201b28c2ee415cb2442224c541abea"},"installation":{"command":"oaupgrade","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a standalone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on HPE Service Pack for ProLiant (SPP), the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a standalone component</strong></p>\n\n<p>This SCEXE component is a self-extracting executable. The SCEXE file unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.<br />\n<br />\nThe general command line syntax for this smart component is</p>\n\n<p>sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</p>\n\n<p>where cpxxxxxx.scexe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul>\n\t<li>-target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The netAddress parameter is the IP address or DNS name of the OA to target. This should be the Active OA if two OA&rsquo;s are in an enclosure. There is a space between the -target and the netAddress parameter.</li>\n\t<li>-user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The username is the userid to use when attempting to login to the OA. There is a space between the -user and the username parameter.</li>\n\t<li>-passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA. There is a space between the -passwd and the password parameter.</li>\n\t<li>-s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The silent option will silently install the firmware, if needed.</li>\n\t<li>-f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>-logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp;&nbsp;This optional parameter is used to redirect the output from the OA flash utility to a different directory than the default location of /var/hp/log/&lt;netAddress&gt;. The redirected location is &lt;path&gt;/hp/log/&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>Download the SCEXE file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>Execute sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are:</p>\n\n<ul>\n\t<li>0 Success</li>\n\t<li>1 Reserved</li>\n\t<li>2 Upgrade is not needed because firmware version is current</li>\n\t<li>3 Upgrade is not needed because newer firmware version is present</li>\n\t<li>4 Target not found</li>\n\t<li>5 User terminated session</li>\n\t<li>6 Incorrect parameter</li>\n\t<li>7 General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、HP Service Pack for ProLiant（SPP）上のHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSCEXEコンポーネントは、自己解凍型実行可能ファイルです。SCEXEファイルは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。<br />\n<br />\nこのSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p>sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</p>\n\n<p>cpxxxxxx.scexeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul>\n\t<li>-target <netAddress>          netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。-targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li>-user <username>              ユーザー名はOAにログインするときに使用するユーザーIDです。-userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li>-passwd <password>           パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。-passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li>-s[ilent]                               サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li>-f[orce]                               forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li>-logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所/var/hp/log/<netAddress>ではなく、別のディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>/hp/log/<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li>アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSCEXEファイルをダウンロードします。</li>\n\t<li>Execute sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li>0 成功</li>\n\t<li>1 予約済み</li>\n\t<li>2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li>3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li>4  ターゲットが見つからない</li>\n\t<li>5 ユーザーによって中止された</li>\n\t<li>6 パラメーターが不正</li>\n\t<li>7 通常の障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Linux"},{"lang":"ko","x_late":"Linux용 온라인 HPE 블레이드 시스템 c-클래스 Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Linux 的联机 HPE BladeSystem c 类板载管理员固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages..</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name (CN) field and IP address in <strong>SAN </strong>field.</strong></li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:40px; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:40px; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p style=\"text-align:justify\">&nbsp;</p>\n\n<p style=\"margin-left:40px; text-align:justify\">&nbsp;The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on OA version 4.90 and less than 4.90. This issue is caused by the introduction of new &nbsp;signature in the iLO5 firmware version 2.10</p>\n\n<p style=\"margin-left:40px; text-align:justify\">. The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18611303","datemodified":"2021-01-28T06:57:56","file_list":["/CP045636_BUILD_6.data","/CP045636.vmexe","/CP045636.vmexe64","/CP045636.vmfile","/CP045636_VMw.zip","/CP045636.xml","/payload.json","/CP045636_VMw.zip/index.xml","/CP045636_VMw.zip/vendor-index.xml","/CP045636_VMw.zip/metadata.zip","/CP045636_VMw.zip/vib20/CP045636/HPE_bootbank_CP045636_HPD1.6-7.0.0.15843807.vib","/CP045636_VMw.zip/metadata.zip/vendor-index.xml","/CP045636_VMw.zip/metadata.zip/vmware.xml","/CP045636_VMw.zip/metadata.zip/vibs/CP045636--990512660941874579.xml","/CP045636_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045636_HPD1.6-7.0.0.15843807.xml"],"md5sum":"c1db67fed7db64a81f2e8cab87886db5","name":"CP045636.zip","release":"2021-01-28T06:55:04","revision":"0","sha1sum":"7bf21941a16555781a229fff6e8343936f0e3834","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP045636","version":"HPD1.6-7.0.0.15843807"}]}],"id":{"product":"3fba85b34f854c9b9b5bb51030ba5e41","version":"22b60414000b47af93fb4e92dd577ef4"},"installation":{"command":"CP041489.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:38:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 64-bit to enable the HPE Smart Array P824i-p MR controller.  This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array P824i-p MRコントローラーを有効にする、SRed Hat Enterprise Linux 7 64-bit用のビルド済みバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"709931","datemodified":"2019-01-23T06:18:43","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-957.el7.x86_64","./lib/modules/3.10.0-957.el7.x86_64/extra","./lib/modules/3.10.0-957.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-957.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"ce36b2c24f30c6a27b2d263405701040","name":"kmod-megaraid_sas-07.706.05.00-14.rhel7u6.x86_64.rpm","release":"2019-01-23T06:17:01","revision":"0","sha1sum":"23958aae2c2b99315d7693f3b7825833bb56a506","size":"693KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.706.05.00-14"},{"bytes":"707491","datemodified":"2019-01-23T06:17:14","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-862.el7.x86_64","./lib/modules/3.10.0-862.el7.x86_64/extra","./lib/modules/3.10.0-862.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-862.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"a5085435ddad70efabd99e7c2d00eedd","name":"kmod-megaraid_sas-07.706.05.00-14.rhel7u5.x86_64.rpm","release":"2019-01-23T06:17:01","revision":"0","sha1sum":"07ed629881ce8b16f2dfaa1bafc8bdf50d5e4d5c","size":"690KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"e5dfbd8525114b8cbf5ba28d97ea5b28","version":"23a1452ef14f40e5a32a246d8974f642"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit Red Hat Enterprise Linux 7 "},{"lang":"ja","x_late":"64-bit Red Hat Enterprise Linux 7用HPE SmartアレイP824i-p MRコントローラードライバー "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-22T09:32:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n\n<p>Added support for Red Hat Enterprise LINUX 7 Update 5</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS35, provides Windows 64-bit support for HPE Smart Array MR controllers"},{"lang":"ja","x_late":"このドライバーMegaSAS35は、HPE SmartアレイMRコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"891960","datemodified":"2021-02-01T15:07:49","file_list":["cp044906.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"md5sum":"fecaf382d721c3803d1933bf73177f8b","name":"cp044906.exe","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"6bc25f712ce28331f41abbbdf8b3e900d2b13541","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.716.3.0"}],"id":{"product":"8dad994cacb24e87b613f12e36f4c8c5","version":"6f1068d84d174a2ab55d0899fd91a1d9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p,MR416i-a, MR216i-p, MR216i-a 64-bit controller driver for Microsoft Windows 2016 edition."}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T08:42:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"MegaSas35.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"105347","datemodified":"2021-03-08T20:12:29","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"beea0c660636fe82866a1376e594c8b8","name":"be2net_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"ae7b8285c1e582c955645fbd589f6604ec304971","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"106974","datemodified":"2021-03-08T20:16:35","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"76dac42c67bd014951471f0991bc9b0f","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"a30cc46dbf6538d0dd24d2386e0e1b1ec89c475d","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7f36bf9643a4e489310dc38c624a57b","version":"1a5ab721a91746cda8d949d335f821dd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB1000JVYZL, MB2000JVYZN, MB3000JVYZP&nbsp;and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17270201","datemodified":"2021-01-27T17:56:54","file_list":["/CP045650_BUILD_7.data","/CP045650.vmexe","/CP045650.vmexe64","/CP045650.vmfile","/CP045650_VMw.zip","/CP045650.xml","/payload.json","/CP045650_VMw.zip/index.xml","/CP045650_VMw.zip/vendor-index.xml","/CP045650_VMw.zip/metadata.zip","/CP045650_VMw.zip/vib20/CP045650/HPE_bootbank_CP045650_HPD3.7-7.0.0.15843807.vib","/CP045650_VMw.zip/metadata.zip/vendor-index.xml","/CP045650_VMw.zip/metadata.zip/vmware.xml","/CP045650_VMw.zip/metadata.zip/vibs/CP045650--2332355253565214820.xml","/CP045650_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045650_HPD3.7-7.0.0.15843807.xml"],"md5sum":"e669b932079f8eaa44fb640ff5962d41","name":"CP045650.zip","release":"2021-01-27T17:54:04","revision":"0","sha1sum":"82bb9b62a21a9341dbb55a6ca6352f88d98dcc8b","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045650","version":"HPD3.7-7.0.0.15843807"}]}],"id":{"product":"9e4dc8db386245f0ad4fc38aef31f547","version":"e9e8048f377d4b7e92ddb287f4524f61"},"installation":{"command":"CP040660.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:49:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33597058","datemodified":"2021-01-28T10:10:27","file_list":["payload.json","U32_2.42_01_23_2021.signed.flash","U32_2.42_01_23_2021.xml"],"md5sum":"00efc1274b1af96b0ed6fa8c20a56946","name":"U32_2.42_01_23_2021.fwpkg","release":"2021-01-28T10:05:10","revision":"0","sha1sum":"eae1c8df838929001ae0f0e67cfd8c10a07e8600","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"7db6f792355b49a58fc4f82d6bbbdd99","version":"f9a5a32bdc364bca9ae2cae0a4390e96"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL360 Gen10（U32）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:15:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"此智能组件为HPE Express托架支持交换卡提供固件"},{"lang":"tw","x_late":"此智慧元件提供適用於 HPE Express 插槽啟用交換器卡的韌體"},{"lang":"ko","x_late":"이 스마트 구성요소는 HPE Express Bay Enablement Switch Card용 펌웨어를 제공합니다."},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Express Bay Enablement Switch Cardのファームウェアを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Express Bay Enablement Switch Card<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 1.78<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.78<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"882144","datemodified":"2018-10-04T12:35:30","file_list":["Config.xml","cp037730.xml","cpqsetup.exe","hdr_Pedali_Rev_0x02_Btlg_0x00.bin","install.dll","pedale-VP3-20171113-1.78-release.rbf"],"md5sum":"85ad50e6556239e6dd2889b13f2dda40","name":"cp037730.exe","release":"2018-10-04T17:33:04","revision":"0","sha1sum":"134eed267b107cf43a7ce3ba0770268ef58b97ca","size":"861KB","target_guids":[],"type_of_change":"0","version":"1.78"}],"id":{"product":"52541fc006a64b3fb03d0df08b39cacd","version":"dadbf3e577d54713b0aa3d97e70ef733"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required after installation for updates to take effect.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>アップデートを有効にするために電源再投入/コールドリブートがインストール後に必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Express Bay Enablement Switch Card"},{"lang":"cn","x_late":"Windows (x64)版在线ROM刷新组件 - HPE Express托架支持交换卡"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 – HPE Express 插槽啟用交換器卡"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성요소 - HPE Express Bay Enablement Switch Card"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Express Bay Enablement Switch Card"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-10-28T03:23:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added HPE Digital Signature</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"HP Gen9 ExpressBay 6SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 6 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Gen9 ExpressBay 5SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP G9 Express Bay 5 SFF Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360p Gen9 2SFF ExpressBay Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"DL360 Gen9 8SFF 4PCIe+4SAS Bkpln","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP Express Bay 6 HDD Switch Card","sw_key_expectedpath":"firmware:sd:switchbackplane"},{"name":"HP DL360G9 2 SFF Express Bay Drive Cage","sw_key_expectedpath":"firmware:sd:switchbackplane"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller.  This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"795275","datemodified":"2020-12-03T07:00:47","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-1127.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"78d6d3eca3496069d715342cc5730591","name":"kmod-megaraid_sas-07.716.02.00_el7.8-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"2c812ade5617729a99b52398f03fade45a974ba0","size":"776KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"795929","datemodified":"2020-12-03T06:58:09","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-1160.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"199db1d734c5a6e37abd80105747d26a","name":"kmod-megaraid_sas-07.716.02.00_el7.9-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"a1ca71824e3eaed238696d65abccb112aed24397","size":"777KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"35899789a3884097b1355c74c1f6e789","version":"1974fff0da494d00bfe2242a69c6f63f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T13:10:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 3."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25226","datemodified":"2021-02-11T00:34:01","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/28b8217315bea3e5ba8b5181d0344ffc78222b","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"c13b8766d07e511ce475f4cad413d239","name":"libbnxt_re-218.0.7.0-rhel8u3.x86_64.rpm","release":"2021-02-11T00:31:30","revision":"0","sha1sum":"6201a9c882b41da5d1801be4dd7bb59f7d39991f","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"b6f6f77678514383bdf949306b683bf3","version":"8acb3a0ef8c64bbb9919ed6dd31cf314"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 3."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The MPT2SAS controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するMPT2SASコントローラードライバーコンポーネント for VMware vSphere 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"282781","datemodified":"2017-05-24T03:40:50","file_list":["/cp032277.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/scsi-mpt2sas-15.10.07.00-1OEM.550.0.0.1331820.x86_64.vib","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/doc/README.txt","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/doc/release_note_scsi-mpt2sas_15.10.07.00-1OEM.550.0.0.1331820.txt","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/vendor-index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/vib20/scsi-mpt2sas/Avago_bootbank_scsi-mpt2sas_15.10.07.00-1OEM.550.0.0.1331820.vib","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vendor-index.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vmware.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/vibs/scsi-mpt2sas--49695319.xml","/mpt2sas-15.10.07.00-esxi5.5-4778920.zip/mpt2sas-15.10.07.00-esxi5.5-offline_bundle-4778920.zip/metadata.zip/bulletins/mpt2sas-15.10.07.00-esxi5.5.xml"],"md5sum":"3ec7611c4b4fdc254ddf813bb82977de","name":"cp032277.zip","release":"2017-05-24T03:38:05","revision":"0","sha1sum":"b00a2c0c0c5c659aea6545f0c7744689695c04bf","size":"276KB","target_guids":[],"type_of_change":"0","version":"2017.01.20","vib_list":[{"name":"scsi-mpt2sas","version":"15.10.07.00-1OEM.550.0.0.1331820"}]}],"id":{"product":"4cc21db9534d4bd8a0a68234daf7c362","version":"f602658f34044dda8776eb434f2c3ccb"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the HPE USB Key Utility:&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us</a>&nbsp;</li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE H2xx SAS/SATA Host Bus Adapter (64-bit) Driver for vSphere 6.5 (Driver Component)."},{"lang":"ja","x_late":"vSphere 6.5用HPE H2xx SAS/SATAホストバスアダプター（64-bi）ドライバー（ドライバーコンポーネント）。"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0087","subdev":"0042","subven":"1590","target_guid":"","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2017-05-26T05:50:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixes minor installation issue with the driver on VMware vSphere 6.5.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:.1in\"><strong>Change implemented in version 2017.01.20(A)</strong>:</p>\n\n<ul>\n\t<li>Updated to support Service Pack for ProLiant version 2017.07.0.<br />\n\t<strong>Note:</strong> If component version 2017.01.20 was previously installed, then it is not necessary to upgrade to version 2017.01.20(A).</li>\n</ul>\n\n<p style=\"margin-left:.1in\"><strong>Issues resolved in version 2017.01.20</strong>:</p>\n\n<ul>\n\t<li>Fixes minor installation issue with the driver on VMware vSphere 6.5.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"scsi-mpt2sas:15.10.07.00-1OEM.550.0.0.1331820","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4992056","datemodified":"2021-01-21T07:19:18","file_list":["Config.xml","cp045968.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"md5sum":"716949a693984d60a340e0ec9c6caaba","name":"cp045968.exe","release":"2021-01-21T07:15:06","revision":"0","sha1sum":"5daac925ba6a13277dd0157999313418fa687045","size":"4MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"id":{"product":"6c76dfc1e26441a48559e0f1bee2891e","version":"cda01dbb84ed4022a59c5007d09ce4a7"},"installation":{"command":"cpqsetup.exe","command_params":"/tD6020 /v2.74 /iTormore-Release-2.74-build-001.bin /lD6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-29T05:10:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v183133/D6020_P07232-008.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15640432","datemodified":"2021-01-28T13:03:03","file_list":["/CP045686_BUILD_4.data","/CP045686.vmexe","/CP045686.vmexe64","/CP045686.vmfile","/CP045686_VMw.zip","/CP045686.xml","/payload.json","/CP045686_VMw.zip/index.xml","/CP045686_VMw.zip/vendor-index.xml","/CP045686_VMw.zip/metadata.zip","/CP045686_VMw.zip/vib20/CP045686/HPE_bootbank_CP045686_HPG1.4-7.0.0.15843807.vib","/CP045686_VMw.zip/metadata.zip/vendor-index.xml","/CP045686_VMw.zip/metadata.zip/vmware.xml","/CP045686_VMw.zip/metadata.zip/vibs/CP045686-1782271973510749125.xml","/CP045686_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045686_HPG1.4-7.0.0.15843807.xml"],"md5sum":"63908d5ea105030602c8abc2967301f1","name":"CP045686.zip","release":"2021-01-28T12:59:09","revision":"0","sha1sum":"686b93c0fae1d65e1aced4e779184d214fdb3f79","size":"14MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP045686","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"d568c20f8443428c99b5421748aa1148","version":"fb6d4d9ef8564204b6bcd4ce9ebe728c"},"installation":{"command":"CP042540.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:22:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD3"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD3"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD3"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD3"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD3"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD3"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0. U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17033794","datemodified":"2021-01-28T18:04:49","file_list":["/CP045722_BUILD_5.data","/CP045722.vmexe","/CP045722.vmexe64","/CP045722.vmfile","/CP045722_VMw.zip","/CP045722.xml","/payload.json","/CP045722_VMw.zip/index.xml","/CP045722_VMw.zip/vendor-index.xml","/CP045722_VMw.zip/metadata.zip","/CP045722_VMw.zip/vib20/CP045722/HPE_bootbank_CP045722_HPD3.5-7.0.0.15843807.vib","/CP045722_VMw.zip/metadata.zip/vendor-index.xml","/CP045722_VMw.zip/metadata.zip/vmware.xml","/CP045722_VMw.zip/metadata.zip/vibs/CP045722--3713940327846329412.xml","/CP045722_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045722_HPD3.5-7.0.0.15843807.xml"],"md5sum":"9293496b6ba9cdf2d5d2f2438fc5a5c2","name":"CP045722.zip","release":"2021-01-28T18:02:04","revision":"0","sha1sum":"85bd9685d12576461ea534fdd60a1f5efb7b8266","size":"16MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045722","version":"HPD3.5-7.0.0.15843807"}]}],"id":{"product":"cf7cb50c769b4b00ab89aa81d9fac797","version":"b5862d7933a746a2af2b6a3bd4f5b7df"},"installation":{"command":"CP041554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:50:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD3"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD3"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD3"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD3"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD3"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD3"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALLHPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>    </strong> None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3474616","datemodified":"2020-12-11T12:16:33","file_list":["cp045603.xml","cpqsetup.exe","payload.json","setup.dll","TARM5ALLHPD3.rel"],"md5sum":"56ea9e545ff5d2905a1ce1e5bea4f1f8","name":"cp045603.exe","release":"2020-12-11T12:06:04","revision":"0","sha1sum":"b3dd8d852d5de8385ba1f81be143e5ec39274ad9","size":"3MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"dd83343964ed4806840a86595ee2254d","version":"d71a32b027b5495a918bf639c8bf866d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:54:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK003840GWHTE Drive"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16319098","datemodified":"2021-01-28T16:33:40","file_list":["/CP045670_BUILD_3.data","/CP045670.vmexe","/CP045670.vmexe64","/CP045670.vmfile","/CP045670_VMw.zip","/CP045670.xml","/payload.json","/CP045670_VMw.zip/index.xml","/CP045670_VMw.zip/vendor-index.xml","/CP045670_VMw.zip/metadata.zip","/CP045670_VMw.zip/vib20/CP045670/HPE_bootbank_CP045670_HPG6.3-7.0.0.15843807.vib","/CP045670_VMw.zip/metadata.zip/vendor-index.xml","/CP045670_VMw.zip/metadata.zip/vmware.xml","/CP045670_VMw.zip/metadata.zip/vibs/CP045670-1758052604316261918.xml","/CP045670_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045670_HPG6.3-7.0.0.15843807.xml"],"md5sum":"652a6773d0a55ee71e182782dec3f609","name":"CP045670.zip","release":"2021-01-28T16:31:04","revision":"0","sha1sum":"b8cef15844e92e93447f167456ba9d7278de874a","size":"15MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045670","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"41769df117cd4b93b1e9b45d5d971451","version":"b10ff1e5df15414d9e785c3b07636c7c"},"installation":{"command":"CP041321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:10:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VO1920JEUQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO1920JEUQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16763296","datemodified":"2021-01-28T13:45:58","file_list":["/CP045690_BUILD_4.data","/CP045690.vmexe","/CP045690.vmexe64","/CP045690.vmfile","/CP045690_VMw.zip","/CP045690.xml","/payload.json","/CP045690_VMw.zip/index.xml","/CP045690_VMw.zip/vendor-index.xml","/CP045690_VMw.zip/metadata.zip","/CP045690_VMw.zip/vib20/CP045690/HPE_bootbank_CP045690_HPD3.4-7.0.0.15843807.vib","/CP045690_VMw.zip/metadata.zip/vendor-index.xml","/CP045690_VMw.zip/metadata.zip/vmware.xml","/CP045690_VMw.zip/metadata.zip/vibs/CP045690-3509087092095740925.xml","/CP045690_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045690_HPD3.4-7.0.0.15843807.xml"],"md5sum":"0a3d1c1462b33805550bec4c8e47c549","name":"CP045690.zip","release":"2021-01-28T13:43:04","revision":"0","sha1sum":"6498e71e8bb8ee469fb0edc9cdcdb7e4362fc166","size":"15MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045690","version":"HPD3.4-7.0.0.15843807"}]}],"id":{"product":"9735a485aa1b43118b5c393eba2635c1","version":"73bd5ea1942c4202ba0b62a3ca784997"},"installation":{"command":"CP040555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:26:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5144662","datemodified":"2020-12-13T16:36:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/CP045483.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/GPM1643SAMD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045483.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045483.scexe"],"md5sum":"4b184426496b1e1bb8c7c2053e344ec1","name":"firmware-hdd-1e51a57347-HPD8-4.1.x86_64.rpm","release":"2020-12-13T16:25:04","revision":"0","sha1sum":"dc9a0fd68ffaf2f5008648b55dfb68fbf58527aa","size":"4MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"36bcc8676cfa4135862a614c063902e6","version":"65d1b8fb7ec04441afdd3b2fa8d69d89"},"installation":{"command":"CP042632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:21:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1145456","datemodified":"2021-01-08T20:15:26","file_list":["cp046117.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs65x64.cat","ixs65x64.din","ixs65x64.inf","ixs65x64.sys","ixsmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXS.dll"],"md5sum":"b6e4291b521480a34af5de9d8a2150b1","name":"cp046117.exe","release":"2021-01-08T19:57:04","revision":"0","sha1sum":"212baf923b8bcd9bb24e6cc2ad8f0bbf92186e49","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e"],"type_of_change":"0","version":"4.1.219.0"}],"id":{"product":"b0ffbe90a5fd48a0bda67da833198a22","version":"fc578a4d7daa458ba0a6fabd7aa33c99"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2016"},{"lang":"ja","x_late":"Windows Server 2016用HPE Intel ixsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixs65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS2, provides Windows 64-bit support for HPE Smart Array P824i-p MR 64-bit controller"},{"lang":"ja","x_late":"このドライバーMegaSAS2は、HPE Smart Array P824i-p MR 64-bitコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1029040","datemodified":"2019-01-23T23:43:47","file_list":["cp034411.xml","cpqsetup.exe","generic.dll","install.xml","megasas2.cat","MegaSAS2.inf","megasas2.pdb","MegaSas2.sys","nodev.inf"],"md5sum":"b85d4500b6f10fa9e1ae6ad418816d98","name":"cp034411.exe","release":"2019-01-24T05:43:01","revision":"0","sha1sum":"735718453b2bc6179045b1d512120760f95b9185","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9d4f074d"],"type_of_change":"1","version":"6.714.18.0"}],"id":{"product":"6c37374d90434a8f868d8552b730c508","version":"aae90018c7554e92860cfe5209d9ceff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR 64-bit controller driver for Microsoft Windows 2016 edition."},{"lang":"ja","x_late":"Windows 2016エディション用HPE Smart Array P824i-p MR 64-bitコントローラードライバー。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-02-02T06:38:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MegaSas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic FastLinQ Open-iSCSI driver for QLogic FastLinQ NICs running under SUSE Linux Enterprise Server 15 SP1."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1467628","datemodified":"2019-10-07T17:21:58","file_list":["./sbin/iscsiadm.ql","./sbin/iscsid.ql","./sbin/iscsistart.ql","./usr/share/smartupdate/qlgc-open-iscsi/component.xml"],"md5sum":"a74cd6ab59559f5ae46a550ae1f1a195","name":"qlgc-open-iscsi-2.0_873.113.sles15sp1-1.x86_64.rpm","release":"2019-10-07T17:21:02","revision":"0","sha1sum":"06feed349e26d6fe77dd3ab909a6d7588ebc1017","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17f154d7"],"type_of_change":"0","version":"2.0-873.113-1"}],"id":{"product":"ebedf697f49c4f66aeb5397b9bfdd557","version":"407a82df276c4a538afaa672234f5233"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package&nbsp;provided by&nbsp;this product is a&nbsp;pre-compiled kernel module driver&nbsp;built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp;HPE has tested and approved this&nbsp;pre-compiled kernel module RPM&nbsp;for use with the specified kernel.&nbsp;</p>\n\n<p>This pre-compiled RPM package&nbsp;may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Open-iSCSI Driver for SUSE Linux Enterprise Server 15 SP1"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"qlgc-open-iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"System Management Homepage 針對單一伺服器管理提供一個統合式檢視，突顯緊密整合的管理功能，包括效能、錯誤、安全性、診斷、組態及軟體變更管理。"},{"lang":"en","x_late":"The System Management Homepage provides a consolidated view for single server management highlighting tightly integrated management functionalities including performance, fault, security, diagnostic, configuration, and software change management."},{"lang":"ko","x_late":"시스템 관리 홈 페이지는 성능, 고장, 진단, 구성 및 소프트웨어 변경 관리를 포함한 통합 관리 기능을 강조한 단일 서버 관리용 통합 뷰를 제공합니다."},{"lang":"cn","x_late":"通过 System Management Homepage，可以统一查看单个服务器管理，特别是综合管理功能，包括性能、故障、安全性、诊断、配置及软件更改管理。"},{"lang":"ja","x_late":"System Management Homepageは、パフォーマンス、障害、セキュリティ、診断、コンフィギュレーション、およびソフトウェアの変更管理を含む統合された管理機能をハイライトする、シングル サーバー管理のための集約した画面を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<p>As per SMH EOL terms, future patch releases will continue to provide fixes for security vulnerabilities &amp; might not provide support to any new OS or Browser.</p>\n"},{"lang":"ja","x_late":"<p>SMH EOLの利用規約によれば、将来のパッチリリースは安全上の脆弱性の解決策の提供を続けます、&新しい OSまたはブラウザーのサポートは提供しません。</p>\n"}],"files":[{"bytes":"14898392","datemodified":"2020-07-13T13:46:12","file_list":["./etc/opt/hp/sslshare","./opt/hp","./opt/hp/hpsmh","./opt/hp/hpsmh/bin","./opt/hp/hpsmh/bin/openssl","./opt/hp/hpsmh/bin/rotatelogs","./opt/hp/hpsmh/bin/smhlogreader","./opt/hp/hpsmh/certs","./opt/hp/hpsmh/conf","./opt/hp/hpsmh/conf/extra","./opt/hp/hpsmh/conf/extra/httpd-autoindex.conf","./opt/hp/hpsmh/conf/extra/httpd-dav.conf","./opt/hp/hpsmh/conf/extra/httpd-default.conf","./opt/hp/hpsmh/conf/extra/httpd-info.conf","./opt/hp/hpsmh/conf/extra/httpd-languages.conf","./opt/hp/hpsmh/conf/extra/httpd-manual.conf","./opt/hp/hpsmh/conf/extra/httpd-mpm.conf","./opt/hp/hpsmh/conf/extra/httpd-multilang-errordoc.conf","./opt/hp/hpsmh/conf/extra/httpd-ssl.conf","./opt/hp/hpsmh/conf/extra/httpd-userdir.conf","./opt/hp/hpsmh/conf/extra/httpd-vhosts.conf","./opt/hp/hpsmh/conf/magic","./opt/hp/hpsmh/conf/mime.types","./opt/hp/hpsmh/conf/original","./opt/hp/hpsmh/conf/original/extra","./opt/hp/hpsmh/conf/original/extra/httpd-autoindex.conf","./opt/hp/hpsmh/conf/original/extra/httpd-dav.conf","./opt/hp/hpsmh/conf/original/extra/httpd-default.conf","./opt/hp/hpsmh/conf/original/extra/httpd-info.conf","./opt/hp/hpsmh/conf/original/extra/httpd-languages.conf","./opt/hp/hpsmh/conf/original/extra/httpd-manual.conf","./opt/hp/hpsmh/conf/original/extra/httpd-mpm.conf","./opt/hp/hpsmh/conf/original/extra/httpd-multilang-errordoc.conf","./opt/hp/hpsmh/conf/original/extra/httpd-ssl.conf","./opt/hp/hpsmh/conf/original/extra/httpd-userdir.conf","./opt/hp/hpsmh/conf/original/extra/httpd-vhosts.conf","./opt/hp/hpsmh/conf/original/httpd.conf","./opt/hp/hpsmh/data","./opt/hp/hpsmh/data/cgi-bin","./opt/hp/hpsmh/data/cgi-bin/CGI","./opt/hp/hpsmh/data/cgi-bin/CGI.pm","./opt/hp/hpsmh/data/cgi-bin/CGI/Util.pm","./opt/hp/hpsmh/data/cgi-bin/IP.pm","./opt/hp/hpsmh/data/cgi-bin/SetSMHData.cgis","./opt/hp/hpsmh/data/help","./opt/hp/hpsmh/data/help/WEB_INF","./opt/hp/hpsmh/data/help/WEB_INF/cgi","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/en","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/en/smh","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/ja","./opt/hp/hpsmh/data/help/WEB_INF/cgi/var/ja/smh","./opt/hp/hpsmh/data/help/about.htm","./opt/hp/hpsmh/data/help/bsscnbar.js","./opt/hp/hpsmh/data/help/chphelp.htm","./opt/hp/hpsmh/data/help/default.css","./opt/hp/hpsmh/data/help/defns.css","./opt/hp/hpsmh/data/help/graphics","./opt/hp/hpsmh/data/help/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/graphics/major_15.png","./opt/hp/hpsmh/data/help/graphics/minor_15.png","./opt/hp/hpsmh/data/help/navpane2.htm","./opt/hp/hpsmh/data/help/nsdnsfix.jar","./opt/hp/hpsmh/data/help/smh","./opt/hp/hpsmh/data/help/smh/en","./opt/hp/hpsmh/data/help/smh/en/common","./opt/hp/hpsmh/data/help/smh/en/common/jquery","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery-1.11.3.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/en/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/en/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/en/content","./opt/hp/hpsmh/data/help/smh/en/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/en/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/en/content/book.html","./opt/hp/hpsmh/data/help/smh/en/content/doc-feedback.html","./opt/hp/hpsmh/data/help/smh/en/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/en/content/images","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/en/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/en/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/en/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/en/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/en/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/hpesm_pri_blk_pos_rgb.png","./opt/hp/hpsmh/data/help/smh/en/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/important.png","./opt/hp/hpsmh/data/help/smh/en/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/en/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/note.png","./opt/hp/hpsmh/data/help/smh/en/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/en/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/en/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/en/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/en/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/en/content/index.html","./opt/hp/hpsmh/data/help/smh/en/content/ix01.html","./opt/hp/hpsmh/data/help/smh/en/content/navheader.html","./opt/hp/hpsmh/data/help/smh/en/content/search","./opt/hp/hpsmh/data/help/smh/en/content/search-01.html","./opt/hp/hpsmh/data/help/smh/en/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/en/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/en/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/en/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/en/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/en/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/en/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/en/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/en/content/styles.css","./opt/hp/hpsmh/data/help/smh/en/content/support.html","./opt/hp/hpsmh/data/help/smh/en/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/en/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/en/graphics","./opt/hp/hpsmh/data/help/smh/en/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/en/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/en/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/en/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/en/index-terms.xml","./opt/hp/hpsmh/data/help/smh/en/index.html","./opt/hp/hpsmh/data/help/smh/en/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/en/smh-home.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/en/smh-logs.html","./opt/hp/hpsmh/data/help/smh/en/smh-nav.html","./opt/hp/hpsmh/data/help/smh/en/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/en/smh-prod.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/en/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/en/smh-set.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/en/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/en/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/en/smh-start.html","./opt/hp/hpsmh/data/help/smh/en/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/en/smh-support.html","./opt/hp/hpsmh/data/help/smh/en/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/en/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/en/structure.xml","./opt/hp/hpsmh/data/help/smh/en/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/en/sys-help.html","./opt/hp/hpsmh/data/help/smh/en/sys-index.html","./opt/hp/hpsmh/data/help/smh/en/sys-legal.html","./opt/hp/hpsmh/data/help/smh/en/sys-map.properties","./opt/hp/hpsmh/data/help/smh/en/sys-toc.html","./opt/hp/hpsmh/data/help/smh/en/sys-unavailable.html","./opt/hp/hpsmh/data/help/smh/en/topics.xml","./opt/hp/hpsmh/data/help/smh/ja","./opt/hp/hpsmh/data/help/smh/ja/common","./opt/hp/hpsmh/data/help/smh/ja/common/jquery","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery-1.4.2.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/ja/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/ja/common/main.js","./opt/hp/hpsmh/data/help/smh/ja/common/webhelp.js","./opt/hp/hpsmh/data/help/smh/ja/content","./opt/hp/hpsmh/data/help/smh/ja/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/ja/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/ja/content/book.html","./opt/hp/hpsmh/data/help/smh/ja/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/ja/content/images","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/important.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/logo.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/note.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/ja/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/ja/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/ja/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/ja/content/index.html","./opt/hp/hpsmh/data/help/smh/ja/content/ix01.html","./opt/hp/hpsmh/data/help/smh/ja/content/navheader.html","./opt/hp/hpsmh/data/help/smh/ja/content/search","./opt/hp/hpsmh/data/help/smh/ja/content/search-01.html","./opt/hp/hpsmh/data/help/smh/ja/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/ja/content/search/stemmers","./opt/hp/hpsmh/data/help/smh/ja/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/ja/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/ja/content/styles.css","./opt/hp/hpsmh/data/help/smh/ja/content/support.html","./opt/hp/hpsmh/data/help/smh/ja/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/ja/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/ja/graphics","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/ja/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/ja/index-terms.xml","./opt/hp/hpsmh/data/help/smh/ja/index.html","./opt/hp/hpsmh/data/help/smh/ja/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/ja/smh-home.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/ja/smh-logs.html","./opt/hp/hpsmh/data/help/smh/ja/smh-nav.html","./opt/hp/hpsmh/data/help/smh/ja/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/ja/smh-prod.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/ja/smh-set.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/ja/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/ja/smh-start.html","./opt/hp/hpsmh/data/help/smh/ja/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/ja/smh-support.html","./opt/hp/hpsmh/data/help/smh/ja/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/ja/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/ja/structure.xml","./opt/hp/hpsmh/data/help/smh/ja/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/ja/sys-help.html","./opt/hp/hpsmh/data/help/smh/ja/sys-index.html","./opt/hp/hpsmh/data/help/smh/ja/sys-legal.html","./opt/hp/hpsmh/data/help/smh/ja/sys-map.properties","./opt/hp/hpsmh/data/help/smh/ja/sys-toc.html","./opt/hp/hpsmh/data/help/smh/ja/sys-unavailable.html","./opt/hp/hpsmh/data/help/smh/ja/topics.xml","./opt/hp/hpsmh/data/help/smh/zh","./opt/hp/hpsmh/data/help/smh/zh/common","./opt/hp/hpsmh/data/help/smh/zh/common/jquery","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery-1.4.2.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery-ui-1.8.2.custom.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery.cookie.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jquery.json-2.4.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/jstorage.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-anim_basic_16x16.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_flat_0_aaaaaa_40x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_flat_55_fbec88_40x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_75_d0e5f5_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_85_dfeffc_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_glass_95_fef1ec_1x400.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_gloss-wave_55_5c9ccc_500x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_f5f8f9_1x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-bg_inset-hard_100_fcfdfd_1x100.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_217bc0_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_2e83ff_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_469bdd_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_6da8d5_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_cd0a0a_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_d8e7f3_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/images/ui-icons_f9bd01_256x240.png","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/theme-redmond/jquery-ui-1.8.2.custom.css","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/file.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder-closed.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder-closed2.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/folder2.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/minus.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/plus.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-black-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-black.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-default-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-default.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-famfamfam-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-famfamfam.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-gray-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-gray.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-red-line.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/images/treeview-red.gif","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.async.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.css","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.min.js","./opt/hp/hpsmh/data/help/smh/zh/common/jquery/treeview/jquery.treeview.pack.js","./opt/hp/hpsmh/data/help/smh/zh/common/main.js","./opt/hp/hpsmh/data/help/smh/zh/common/webhelp.js","./opt/hp/hpsmh/data/help/smh/zh/content","./opt/hp/hpsmh/data/help/smh/zh/content/Sys-legal.html","./opt/hp/hpsmh/data/help/smh/zh/content/bk01-toc.html","./opt/hp/hpsmh/data/help/smh/zh/content/book.html","./opt/hp/hpsmh/data/help/smh/zh/content/ess_nav_frame.html","./opt/hp/hpsmh/data/help/smh/zh/content/images","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/1.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/1.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/10.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/10.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/2.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/2.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/3.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/3.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/4.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/4.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/5.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/5.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/6.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/6.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/7.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/7.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/8.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/8.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/9.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/callouts/9.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/caution.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/caution.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/cautionsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/closed_book.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/collasped_closed_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/draft.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/expanded_open_book_icon.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconCritical.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconDisabled.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconInfo.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconNormal.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconToolsUtilities.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconUnknown.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/iconWarning.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/major_15.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/graphics/minor_15.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/hp_small_sig.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/important.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/important.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/importantsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/logo.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/logo_sm.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/note.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/note.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/notesm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/open_book.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/spacer.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/tip.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/tip.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/tipsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/topic_page.jpg","./opt/hp/hpsmh/data/help/smh/zh/content/images/warning.gif","./opt/hp/hpsmh/data/help/smh/zh/content/images/warning.png","./opt/hp/hpsmh/data/help/smh/zh/content/images/warningsm.gif","./opt/hp/hpsmh/data/help/smh/zh/content/index.html","./opt/hp/hpsmh/data/help/smh/zh/content/ix01.html","./opt/hp/hpsmh/data/help/smh/zh/content/navheader.html","./opt/hp/hpsmh/data/help/smh/zh/content/search","./opt/hp/hpsmh/data/help/smh/zh/content/search-01.html","./opt/hp/hpsmh/data/help/smh/zh/content/search/encoder.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/htmlFileInfoList.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/htmlFileList.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-1.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-2.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/index-3.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/nwSearchFnt.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/nwSearchFnt_asian.js","./opt/hp/hpsmh/data/help/smh/zh/content/search/stemmers","./opt/hp/hpsmh/data/help/smh/zh/content/smh-helppage.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-home.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs-errlog.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs-smhpLog.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-logs.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-nav.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-p-pages.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-prod.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-credits.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-data-source.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-security.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-snmp-config.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-ui-options.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-uiproperties.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set-user-preferences.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-set.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-IPBinding.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-IPResLogin.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-anonAccess.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-kerberos-users.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-multihomedCert.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-port.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-port2301.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-serverCert.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-timeouts.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-trustMode.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-trustedServers.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-ss-userGroups.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-autoImport.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-firewallSettings.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-login.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start-logout.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-start.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-support-lang.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-support.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-tasks.html","./opt/hp/hpsmh/data/help/smh/zh/content/smh-webapps.html","./opt/hp/hpsmh/data/help/smh/zh/content/styles.css","./opt/hp/hpsmh/data/help/smh/zh/content/support.html","./opt/hp/hpsmh/data/help/smh/zh/content/sys-glossary.html","./opt/hp/hpsmh/data/help/smh/zh/content/sys-help.html","./opt/hp/hpsmh/data/help/smh/zh/topics.xml","./opt/hp/hpsmh/data/help/webhelp.jar","./opt/hp/hpsmh/data/help/webhelp.res","./opt/hp/hpsmh/data/help/xidistyle","./opt/hp/hpsmh/data/help/xidistyle/3.1","./opt/hp/hpsmh/data/help/xidistyle/3.1/img","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_006699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_336666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_3399cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_666633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_669999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_66ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_993300.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_996666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_999966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_99cccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_99ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc3333.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc6633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9933.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cc9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_cccc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff6600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff6666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9900.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ff9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcc66.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_ffcccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_669966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_nav_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_sm_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/a_th_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/arrows/rarrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/blank-icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/bl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/br_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/corners/tr_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/1.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/1.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/10.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/11.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/11.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/12.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/12.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/13.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/13.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/14.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/14.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/15.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/15.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/2.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/3.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/3.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/4.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/4.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/5.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/5.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/6.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/6.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/7.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/7.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/8.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/8.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/9.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/callouts/9.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/caution.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/draft.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/home.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/home.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/important.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/next.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/next.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/note.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/prev.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/prev.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/tip.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-minus.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/toc-plus.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/up.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/up.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.png","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/docbook/warning.tif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_arrow_submit.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_leftnav_background.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/hpc60_topnav_hp_logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/icon_print.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/s.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/spacer.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/img/topgrey_30.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/js","./opt/hp/hpsmh/data/help/xidistyle/3.1/js/hpweb_country_pulldown.js","./opt/hp/hpsmh/data/help/xidistyle/3.1/js/hpweb_utilities.js","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/de/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/docbook.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/en/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/es/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/fr/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/it/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ja/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/ko/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_cn/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/styles/zh_tw/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.1/us","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/buy_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/buy_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/country.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/english.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/english2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/home_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/home_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/prodserv_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/prodserv_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/solutions_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/solutions_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/support_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.1/us/eng/img/top/support_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2","./opt/hp/hpsmh/data/help/xidistyle/3.2/img","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_006699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_336666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_3399cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_666633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_669999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_66ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_993300.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_996666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_999966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_99cccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_99ccff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc3333.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc6633.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9933.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cc9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_cccc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff6600.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff6666.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9900.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ff9999.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcc66.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcc99.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_ffcccc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_003366.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_336699.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_669966.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_6699cc.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_nav_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_sm_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/a_th_ffffff.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/arrows/rarrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/blank-icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/bl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/br_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tl_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_corner_10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_corner_1010.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/corners/tr_navcorner_20.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/1.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/1.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/10.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/10.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/11.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/11.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/12.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/12.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/13.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/13.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/14.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/14.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/15.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/15.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/2.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/3.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/3.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/4.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/4.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/5.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/5.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/6.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/6.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/7.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/7.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/8.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/8.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/9.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/callouts/9.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/caution.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/draft.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/home.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/home.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/important.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/next.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/next.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/note.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/prev.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/prev.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/t-bullet.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/tip.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-blank.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-minus.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/toc-plus.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/up.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/up.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.svg","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/docbook/warning.tif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_arrow_submit.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_leftnav_background.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/hpc60_topnav_hp_logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/icon_print.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/important.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/logo.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/pdf_icon.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/s.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/s.png","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/spacer.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/img/topgrey_30.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/js","./opt/hp/hpsmh/data/help/xidistyle/3.2/js/hpweb_country_pulldown.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/js/hpweb_utilities.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/de/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/docbook.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/en/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/es/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/fr/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/it/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ja/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/ko/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/xididoc.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_cn/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_ns4.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_strd.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_win_ie.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/styles/zh_tw/hpweb_styles_win_ie6.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/aural.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/blue_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/default.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/green_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/magenta_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/orange_theme.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/css/print.css","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/bullet.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/grey_panel_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_shortcut_arrow.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_critical.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_disabled.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_informational.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_major.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_minor.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_normal.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_unknown.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_status_warning.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_tray_contract_u.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/icon_tray_expand_d.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_local_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_local_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_notch_left.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/navbar_notch_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_identifier_icon.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_masthead_photo_large.jpg","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/placeholder_masthead_photo_small.jpg","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/progress_bar_large.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/progress_bar_small.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/sorted_column_asc_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/sorted_column_desc_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/tab_set_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/tab_set_secondary_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/blue/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/green/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/magenta/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/button_tree_contract.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/button_tree_expand.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/de.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/en.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/es.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/fr.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/it.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/ja.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/ko.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/zh_cn.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/language/zh_tw.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_checkbox.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_parent_bg.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/tab_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/images/themes/orange/tab_secondary_right.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/buttonManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/dropdownMenuManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/global.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/navigationControlManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/tabManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/tableManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/transferBoxManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/treeManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/uiassets/js/treeTableManager.js","./opt/hp/hpsmh/data/help/xidistyle/3.2/us","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/buy_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/buy_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/country.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/english.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/english2.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/home_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/home_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/prodserv_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/prodserv_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/solutions_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/solutions_on.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/support_off.gif","./opt/hp/hpsmh/data/help/xidistyle/3.2/us/eng/img/top/support_on.gif","./opt/hp/hpsmh/data/htdocs","./opt/hp/hpsmh/data/htdocs/addcert.php.en","./opt/hp/hpsmh/data/htdocs/agents.php","./opt/hp/hpsmh/data/htdocs/aiclogin.php.en","./opt/hp/hpsmh/data/htdocs/aiclogin_cert.php","./opt/hp/hpsmh/data/htdocs/chp.js.en","./opt/hp/hpsmh/data/htdocs/chpblank.htm","./opt/hp/hpsmh/data/htdocs/chpbrdg.php.en","./opt/hp/hpsmh/data/htdocs/chpdata.php.en","./opt/hp/hpsmh/data/htdocs/chphead.php.en","./opt/hp/hpsmh/data/htdocs/chpif.js","./opt/hp/hpsmh/data/htdocs/chplinkstrt.php","./opt/hp/hpsmh/data/htdocs/chpload.htm.en","./opt/hp/hpsmh/data/htdocs/chpstrt.php.en","./opt/hp/hpsmh/data/htdocs/chpview.php","./opt/hp/hpsmh/data/htdocs/cpqlogin.htm","./opt/hp/hpsmh/data/htdocs/cpqlogin.php.en","./opt/hp/hpsmh/data/htdocs/cpqopts.htm","./opt/hp/hpsmh/data/htdocs/cpqopts.php.en","./opt/hp/hpsmh/data/htdocs/credits.php.en","./opt/hp/hpsmh/data/htdocs/css","./opt/hp/hpsmh/data/htdocs/css/aural.css","./opt/hp/hpsmh/data/htdocs/css/blue_theme.css","./opt/hp/hpsmh/data/htdocs/css/common.css","./opt/hp/hpsmh/data/htdocs/css/common_ie.css","./opt/hp/hpsmh/data/htdocs/css/default.css","./opt/hp/hpsmh/data/htdocs/css/green_theme.css","./opt/hp/hpsmh/data/htdocs/css/home.css","./opt/hp/hpsmh/data/htdocs/css/index.css","./opt/hp/hpsmh/data/htdocs/css/logon.css","./opt/hp/hpsmh/data/htdocs/css/magenta_theme.css","./opt/hp/hpsmh/data/htdocs/css/orange_theme.css","./opt/hp/hpsmh/data/htdocs/css/print.css","./opt/hp/hpsmh/data/htdocs/custcert.php.en","./opt/hp/hpsmh/data/htdocs/custom_ui","./opt/hp/hpsmh/data/htdocs/custom_ui/README.txt","./opt/hp/hpsmh/data/htdocs/errlog.php.en","./opt/hp/hpsmh/data/htdocs/failed.htm","./opt/hp/hpsmh/data/htdocs/favicon.ico","./opt/hp/hpsmh/data/htdocs/groups.php.en","./opt/hp/hpsmh/data/htdocs/gsearch.php.en","./opt/hp/hpsmh/data/htdocs/images","./opt/hp/hpsmh/data/htdocs/images/blank.gif","./opt/hp/hpsmh/data/htdocs/images/bullet.gif","./opt/hp/hpsmh/data/htdocs/images/divider3d_horiz.gif","./opt/hp/hpsmh/data/htdocs/images/grey_panel_bg.gif","./opt/hp/hpsmh/data/htdocs/images/header_title.gif","./opt/hp/hpsmh/data/htdocs/images/hpInvent.gif","./opt/hp/hpsmh/data/htdocs/images/hpInvent.jpg","./opt/hp/hpsmh/data/htdocs/images/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/hpesm_spec_grn_rev_rgb.png","./opt/hp/hpsmh/data/htdocs/images/hplogo.gif","./opt/hp/hpsmh/data/htdocs/images/icon_bullet_list.gif","./opt/hp/hpsmh/data/htdocs/images/icon_shortcut_arrow.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_critical.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_disabled.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_informational.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_major.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_minor.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_normal.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_unknown.gif","./opt/hp/hpsmh/data/htdocs/images/icon_status_warning.gif","./opt/hp/hpsmh/data/htdocs/images/icon_tray_contract_u.gif","./opt/hp/hpsmh/data/htdocs/images/icon_tray_expand_d.gif","./opt/hp/hpsmh/data/htdocs/images/icons","./opt/hp/hpsmh/data/htdocs/images/icons/cpqopts.png","./opt/hp/hpsmh/data/htdocs/images/icons/custcert.png","./opt/hp/hpsmh/data/htdocs/images/icons/generic.png","./opt/hp/hpsmh/data/htdocs/images/icons/groups.png","./opt/hp/hpsmh/data/htdocs/images/icons/http_log.png","./opt/hp/hpsmh/data/htdocs/images/icons/ipbind.png","./opt/hp/hpsmh/data/htdocs/images/icons/iprstrct.png","./opt/hp/hpsmh/data/htdocs/images/icons/kerberos.png","./opt/hp/hpsmh/data/htdocs/images/icons/local.png","./opt/hp/hpsmh/data/htdocs/images/icons/overallStatus.png","./opt/hp/hpsmh/data/htdocs/images/icons/port2301.png","./opt/hp/hpsmh/data/htdocs/images/icons/security.png","./opt/hp/hpsmh/data/htdocs/images/icons/smh.png","./opt/hp/hpsmh/data/htdocs/images/icons/smh_log.png","./opt/hp/hpsmh/data/htdocs/images/icons/tcert.png","./opt/hp/hpsmh/data/htdocs/images/icons/timeouts.png","./opt/hp/hpsmh/data/htdocs/images/icons/ui_con_fig.png","./opt/hp/hpsmh/data/htdocs/images/icons/user_prefs.png","./opt/hp/hpsmh/data/htdocs/images/iconview.gif","./opt/hp/hpsmh/data/htdocs/images/legend.gif","./opt/hp/hpsmh/data/htdocs/images/legends.gif","./opt/hp/hpsmh/data/htdocs/images/listview.gif","./opt/hp/hpsmh/data/htdocs/images/logon_title.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_local_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_local_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_notch_left.gif","./opt/hp/hpsmh/data/htdocs/images/navbar_notch_right.gif","./opt/hp/hpsmh/data/htdocs/images/photo.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_ff.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_play.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_button_img_rewind.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_identifier_icon.gif","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_800.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_large.jpg","./opt/hp/hpsmh/data/htdocs/images/placeholder_masthead_photo_small.jpg","./opt/hp/hpsmh/data/htdocs/images/progress_bar_large.gif","./opt/hp/hpsmh/data/htdocs/images/progress_bar_medium.gif","./opt/hp/hpsmh/data/htdocs/images/progress_bar_small.gif","./opt/hp/hpsmh/data/htdocs/images/refresh.gif","./opt/hp/hpsmh/data/htdocs/images/sorted_column_asc_bg.gif","./opt/hp/hpsmh/data/htdocs/images/sorted_column_desc_bg.gif","./opt/hp/hpsmh/data/htdocs/images/status","./opt/hp/hpsmh/data/htdocs/images/status/critical_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/critical_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/disabled_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/document_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/document_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_critical.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_disabled.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_informational.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_major.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_minor.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_normal.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_unknown.gif","./opt/hp/hpsmh/data/htdocs/images/status/icon_status_warning.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/info_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/major_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/minor_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/normal_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/status_none.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/transparent_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/unknown_7.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_11.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_15.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_20.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_32.gif","./opt/hp/hpsmh/data/htdocs/images/status/warning_7.gif","./opt/hp/hpsmh/data/htdocs/images/tab_set_bg.gif","./opt/hp/hpsmh/data/htdocs/images/tab_set_secondary_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes","./opt/hp/hpsmh/data/htdocs/images/themes/blue","./opt/hp/hpsmh/data/htdocs/images/themes/blue/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/blue/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green","./opt/hp/hpsmh/data/htdocs/images/themes/green/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/green/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/magenta/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange","./opt/hp/hpsmh/data/htdocs/images/themes/orange/button_tree_contract.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/button_tree_expand.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/hp_logo_invert.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/logo_hp_largemasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/logo_hp_smallmasthead.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_checkbox.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_global_trigger_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_global_trigger_over_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_parent_bg.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/navbar_parent_bg_over.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/tab_right.gif","./opt/hp/hpsmh/data/htdocs/images/themes/orange/tab_secondary_right.gif","./opt/hp/hpsmh/data/htdocs/in.php.en","./opt/hp/hpsmh/data/htdocs/index.php.en","./opt/hp/hpsmh/data/htdocs/ipbind.php.en","./opt/hp/hpsmh/data/htdocs/iprstrct.php.en","./opt/hp/hpsmh/data/htdocs/js","./opt/hp/hpsmh/data/htdocs/js/BoxManager.js","./opt/hp/hpsmh/data/htdocs/js/FormManager.js","./opt/hp/hpsmh/data/htdocs/js/Index.js","./opt/hp/hpsmh/data/htdocs/js/LayoutManager.js","./opt/hp/hpsmh/data/htdocs/js/PanelManager.js","./opt/hp/hpsmh/data/htdocs/js/buttonManager.js","./opt/hp/hpsmh/data/htdocs/js/dropdownMenuManager.js","./opt/hp/hpsmh/data/htdocs/js/error_table.js","./opt/hp/hpsmh/data/htdocs/js/functions.js","./opt/hp/hpsmh/data/htdocs/js/global.js","./opt/hp/hpsmh/data/htdocs/js/help_language.js.de","./opt/hp/hpsmh/data/htdocs/js/help_language.js.en","./opt/hp/hpsmh/data/htdocs/js/help_language.js.es","./opt/hp/hpsmh/data/htdocs/js/help_language.js.fr","./opt/hp/hpsmh/data/htdocs/js/help_language.js.it","./opt/hp/hpsmh/data/htdocs/js/help_language.js.ja","./opt/hp/hpsmh/data/htdocs/js/help_language.js.ko","./opt/hp/hpsmh/data/htdocs/js/help_language.js.zh-cn","./opt/hp/hpsmh/data/htdocs/js/help_language.js.zh-tw","./opt/hp/hpsmh/data/htdocs/js/navigationControlManager.js","./opt/hp/hpsmh/data/htdocs/js/tabManager.js","./opt/hp/hpsmh/data/htdocs/js/tableManager.js","./opt/hp/hpsmh/data/htdocs/js/transferBoxManager.js","./opt/hp/hpsmh/data/htdocs/js/treeManager.js","./opt/hp/hpsmh/data/htdocs/js/treeTableManager.js","./opt/hp/hpsmh/data/htdocs/js/ui.js","./opt/hp/hpsmh/data/htdocs/lang","./opt/hp/hpsmh/data/htdocs/lang.php","./opt/hp/hpsmh/data/htdocs/lang/en","./opt/hp/hpsmh/data/htdocs/lang/en/language.php","./opt/hp/hpsmh/data/htdocs/lang/en/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang/ja","./opt/hp/hpsmh/data/htdocs/lang/ja/language.php","./opt/hp/hpsmh/data/htdocs/lang/ja/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang/zh","./opt/hp/hpsmh/data/htdocs/lang/zh/language.php","./opt/hp/hpsmh/data/htdocs/lang/zh/log_messages.php","./opt/hp/hpsmh/data/htdocs/lang_webapp.php","./opt/hp/hpsmh/data/htdocs/legend.html","./opt/hp/hpsmh/data/htdocs/local.php.en","./opt/hp/hpsmh/data/htdocs/log_engine.php","./opt/hp/hpsmh/data/htdocs/message.php.en","./opt/hp/hpsmh/data/htdocs/message_strings.php","./opt/hp/hpsmh/data/htdocs/mod_jk2","./opt/hp/hpsmh/data/htdocs/mod_jk2/CHANGES.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/CHANGES.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/INSTALL.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/LICENSE","./opt/hp/hpsmh/data/htdocs/mod_jk2/NOTICE","./opt/hp/hpsmh/data/htdocs/mod_jk2/README.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/STATUS.txt","./opt/hp/hpsmh/data/htdocs/mod_jk2/common","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/AJPv13-extensions-proposal.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/AJPv13.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/doccontrib.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/common/tools.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/faq.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/images","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/corner.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jakarta.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jk2.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/jk2.png","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/mod_jk.jpg","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/pixel.gif","./opt/hp/hpsmh/data/htdocs/mod_jk2/images/tomcat.ico","./opt/hp/hpsmh/data/htdocs/mod_jk2/index.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/confighowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtc.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtccom.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configtcex.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configweb.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configwebcom.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/configwebex.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/davhowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/installhowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/jk2/vhosthowto.html","./opt/hp/hpsmh/data/htdocs/mod_jk2/style.css","./opt/hp/hpsmh/data/htdocs/navfile.htm","./opt/hp/hpsmh/data/htdocs/no_javascript.php","./opt/hp/hpsmh/data/htdocs/notfound.php","./opt/hp/hpsmh/data/htdocs/port2301_autostart.php","./opt/hp/hpsmh/data/htdocs/red2301.html.en","./opt/hp/hpsmh/data/htdocs/showcert.php.en","./opt/hp/hpsmh/data/htdocs/smh.css","./opt/hp/hpsmh/data/htdocs/smhhelp.php.en","./opt/hp/hpsmh/data/htdocs/smhsupport.php","./opt/hp/hpsmh/data/htdocs/smhutil","./opt/hp/hpsmh/data/htdocs/smhutil/snmpchp.php.en","./opt/hp/hpsmh/data/htdocs/smhutil/snmpchp.php.ja","./opt/hp/hpsmh/data/htdocs/success.htm","./opt/hp/hpsmh/data/htdocs/timeouts.php.en","./opt/hp/hpsmh/data/htdocs/treebody.js.en","./opt/hp/hpsmh/data/htdocs/treehead.htm.en","./opt/hp/hpsmh/data/htdocs/treehead.htm.ja","./opt/hp/hpsmh/data/htdocs/treetail.htm.en","./opt/hp/hpsmh/data/htdocs/trstcert.php.en","./opt/hp/hpsmh/data/htdocs/ui_config.php","./opt/hp/hpsmh/data/htdocs/user_prefs.php","./opt/hp/hpsmh/data/isdocs","./opt/hp/hpsmh/data/isdocs/red2301.html.en","./opt/hp/hpsmh/data/isdocs/red2301.html.ja","./opt/hp/hpsmh/data/webapp-data","./opt/hp/hpsmh/hpsum","./opt/hp/hpsmh/hpsum/adapter_mod","./opt/hp/hpsmh/lbin","./opt/hp/hpsmh/lbin/kill_smhstartd","./opt/hp/hpsmh/lbin/smhredirect","./opt/hp/hpsmh/lbin/smhstartd","./opt/hp/hpsmh/lbin/smhstartd_ipv4","./opt/hp/hpsmh/lbin/time_out","./opt/hp/hpsmh/lbin/timeout_restart","./opt/hp/hpsmh/lbin/timeoutmonitor","./opt/hp/hpsmh/lib","./opt/hp/hpsmh/lib/apr.exp","./opt/hp/hpsmh/lib/aprutil.exp","./opt/hp/hpsmh/lib/engines","./opt/hp/hpsmh/lib/libapr-1.la","./opt/hp/hpsmh/lib/libapr-1.so","./opt/hp/hpsmh/lib/libapr-1.so.0","./opt/hp/hpsmh/lib/libapr-1.so.0.5.2","./opt/hp/hpsmh/lib/libaprutil-1.la","./opt/hp/hpsmh/lib/libaprutil-1.so","./opt/hp/hpsmh/lib/libaprutil-1.so.0","./opt/hp/hpsmh/lib/libaprutil-1.so.0.5.4","./opt/hp/hpsmh/lib/libcrypto.so","./opt/hp/hpsmh/lib/libcrypto.so.1.0.0","./opt/hp/hpsmh/lib/libcurl.la","./opt/hp/hpsmh/lib/libcurl.so","./opt/hp/hpsmh/lib/libcurl.so.4","./opt/hp/hpsmh/lib/libcurl.so.4.4.0","./opt/hp/hpsmh/lib/libpcre.la","./opt/hp/hpsmh/lib/libpcre.so","./opt/hp/hpsmh/lib/libpcre.so.1","./opt/hp/hpsmh/lib/libpcre.so.1.2.9","./opt/hp/hpsmh/lib/libsmhlogwriter.so","./opt/hp/hpsmh/lib/libssl.so","./opt/hp/hpsmh/lib/libssl.so.1.0.0","./opt/hp/hpsmh/lib/libxml2.la","./opt/hp/hpsmh/lib/libxml2.so","./opt/hp/hpsmh/lib/libxml2.so.2","./opt/hp/hpsmh/lib/libxml2.so.2.9.4","./opt/hp/hpsmh/lib/libz.so","./opt/hp/hpsmh/lib/libz.so.1","./opt/hp/hpsmh/lib/libz.so.1.2.11","./opt/hp/hpsmh/lib32","./opt/hp/hpsmh/lib32/libcrypto.so.1.0.0","./opt/hp/hpsmh/lib32/libssl.so.1.0.0","./opt/hp/hpsmh/logs","./opt/hp/hpsmh/modules","./opt/hp/hpsmh/modules/httpd.exp","./opt/hp/hpsmh/modules/libphp5.so","./opt/hp/hpsmh/modules/mod_access_compat.so","./opt/hp/hpsmh/modules/mod_actions.so","./opt/hp/hpsmh/modules/mod_alias.so","./opt/hp/hpsmh/modules/mod_authz_core.so","./opt/hp/hpsmh/modules/mod_cgi.so","./opt/hp/hpsmh/modules/mod_dir.so","./opt/hp/hpsmh/modules/mod_env.so","./opt/hp/hpsmh/modules/mod_headers.so","./opt/hp/hpsmh/modules/mod_imagemap.so","./opt/hp/hpsmh/modules/mod_log_config.so","./opt/hp/hpsmh/modules/mod_mime.so","./opt/hp/hpsmh/modules/mod_negotiation.so","./opt/hp/hpsmh/modules/mod_proxy.so","./opt/hp/hpsmh/modules/mod_proxy_ajp.so","./opt/hp/hpsmh/modules/mod_proxy_balancer.so","./opt/hp/hpsmh/modules/mod_proxy_connect.so","./opt/hp/hpsmh/modules/mod_proxy_ftp.so","./opt/hp/hpsmh/modules/mod_proxy_http.so","./opt/hp/hpsmh/modules/mod_reqtimeout.so","./opt/hp/hpsmh/modules/mod_rewrite.so","./opt/hp/hpsmh/modules/mod_setenvif.so","./opt/hp/hpsmh/modules/mod_smh_help.so","./opt/hp/hpsmh/modules/mod_socache_shmcb.so","./opt/hp/hpsmh/modules/mod_unixd.so","./opt/hp/hpsmh/sbin","./opt/hp/hpsmh/sbin/cgi_pam","./opt/hp/hpsmh/sbin/hpsmhd","./opt/hp/hpsmh/sbin/php","./opt/hp/hpsmh/sbin/smhMonitor","./opt/hp/hpsmh/sbin/smhconfig","./opt/hp/hpsmh/sbin/smhrun","./opt/hp/hpsmh/sbin/smhstart","./opt/hp/hpsmh/session","./opt/hp/hpsmh/session/php","./opt/hp/hpsmh/support","./opt/hp/hpsmh/support/cs-final.sh","./opt/hp/hpsmh/support/fixperms","./opt/hp/hpsmh/support/hpsmhd.redhat","./opt/hp/hpsmh/support/hpsmhd.service","./opt/hp/hpsmh/support/hpsmhd.united1","./opt/hp/hpsmh/support/sysmgthp.redhat","./opt/hp/hpsmh/support/sysmgthp.rh32","./opt/hp/hpsmh/support/sysmgthp.united1","./opt/hp/hpsmh/tmp","./opt/hp/hpsmh/webapp","./usr/local/hp/hpSMHSetup","./usr/local/hp/hpSMHSetup.pl","./usr/local/hp/hpSMHSetup/L10N","./usr/local/hp/hpSMHSetup/L10N.pm","./usr/local/hp/hpSMHSetup/L10N/en.pm","./usr/local/hp/hpbacl.sh","./usr/local/hp/hpfdtn.sh","./usr/local/hp/hpwebsetup","./usr/local/hp/shmchk"],"md5sum":"5ecbadbd2f599a9355ed72c707dacbfa","name":"hpsmh-7.6.6-2.x86_64.rpm","release":"2020-07-13T13:44:13","revision":"0","sha1sum":"84f11c568725350cd7a2becfbdb0c6201a92723d","size":"14MB","target_guids":[],"type_of_change":"1","version":"7.6.6-2"}],"id":{"product":"C8718","version":"2297bd211a9e45a4b4f6c9a8aba7aa43"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the rpm package to a directory on your hard drive and change the directory accordingly. Use the following commands for specific tasks:\n<ol>\n <li>\n  <strong>Installation</strong>: rpm -ivh hpsmh-&lt; version &gt;.x86_64.rpm</li>\n <li>\n  <strong>Upgrade</strong> (from lower version to higher version): rpm -Uvh hpsmh-&lt;version&gt;.x86_64.rpm&gt;</li>\n <li>\n  <strong>Reinstallation</strong> (of same version): rpm -Uvh hpsmh-&lt;version&gt;.x86_64.rpm</li>\n <li>\n  <strong>Downgrade</strong> (from higher version to lower version): User needs to uninstall the higher version (rpm &ndash;e hpsmh-&lt;version&gt;) and then install the lower version (rpm -ivh hpsmh-&lt;version&gt;.x86_64.rpm).</li>\n</ol>\n"},{"lang":"ja","x_late":"ハードディスクドライブのディレクトリにrpmパッケージをダウンロードし、そのディレクトリに移動します。 固有のタスクのために次のコマンドを使用します。\n<ol>\n <li>\n  <strong>インストール</strong>： rpm -ivh hpsmh-< version >.x86_64.rpm</li>\n <li>\n  <strong>アップグレード</strong> (下位バージョンから上位バージョンへ)： rpm -Uvh hpsmh-<version>.x86_64.rpm></li>\n <li>\n  <strong>再インストール</strong> (同じバージョン)： rpm -Uvh hpsmh-<version>.x86_64.rpm</li>\n <li>\n  <strong>ダウングレード</strong> (上位バージョンから下位バージョンへ)： ユーザーは上位バージョンをアンインストールする(rpm –e hpsmh-<version>)必要があり、その後下位バージョンをインストールしてください(rpm -ivh hpsmh-<version>.x86_64.rpm)。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (AMD64/EM64T) 的 HPE System Management Homepage"},{"lang":"en","x_late":"HPE System Management Homepage for Linux (AMD64/EM64T)"},{"lang":"ko","x_late":"Linux(AMD64/EM64T)용 HPE System Management Homepage"},{"lang":"cn","x_late":"用于 Linux (AMD64/EM64T) 的 HPE System Management Homepage"},{"lang":"ja","x_late":"HPE System Management Homepage for Linux（AMD64/EM64T）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Oracle Linux 5 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Desktop (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-10T06:29:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>New OS Support</p>\n\n<ul>\n\t<li>RHEL 8</li>\n\t<li>SLES15 SP1</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated the following components:</p>\n\n<ul>\n\t<li>&nbsp;&nbsp;&nbsp; Apache to version 2.4.41</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"","value":"HPE System Management Homepage Software"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"hpsmh","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1928920","datemodified":"2021-02-09T08:23:28","file_list":["cp043868.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"9d3357dac339f5291af7a70f41c5268a","name":"cp043868.exe","release":"2021-02-09T08:10:03","revision":"0","sha1sum":"f6894d8d01fbbd4e3aef4e92dc08fc07e5c651aa","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"7c884a6e0000498786309bba3a9762e5","version":"67bf671d39884296b587d382d441a6b6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox CX5 and CX6DX Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30117","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30040","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30042","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30102","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30047","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30116","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30052","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6169417","datemodified":"2020-12-17T20:07:49","file_list":["/CP046426.vmexe","/CP046426.vmfile","/CP046426.xml","/README.txt"],"md5sum":"268000f0f44688debd3eaab81a29b584","name":"CP046426.zip","release":"2020-12-18T02:05:11","revision":"0","sha1sum":"26655ae288448b4dec5ea53499bac74f724cdc51","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020","vib_list":[]}],"id":{"product":"0f73895a23994ef3b308a27affe1d7ce","version":"bcdf5e6fbf004841a66fc62ccfd32755"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.</p>\n\n<p>The minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。</p>\n\n<p>6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:09:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller.  This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"lang":"ja","x_late":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"571304","datemodified":"2021-01-21T05:46:31","file_list":["cp046333.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"md5sum":"65e2e61e11e774da6e6e845f496b29fc","name":"cp046333.exe","release":"2021-04-23T00:00:00","revision":"1","sha1sum":"2e9c7db446a1038c25379c906ea3782fc92aaa95","size":"557KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"e1ccea24a14a427dabc2aadd846feea9","version":"5ef161aeb3f944638d41ffa4f78029d4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-28T10:30:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed branding issue</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"necheschif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7038837","datemodified":"2021-03-25T05:19:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/CP047361.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/KPE60X1GHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047361.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047361.scexe"],"md5sum":"9951b97ba8afc040a0d83db15789723c","name":"firmware-hdd-54addf5312-HPK3-5.1.x86_64.rpm","release":"2021-03-25T05:07:04","revision":"0","sha1sum":"cb1fe2ee7e69c2d92c0efb136e3567700b99bc56","size":"6MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"3d004333c656491289fdf09d5881fcdd","version":"9cb3c5e2b3ae414b9a88736aa662a6e9"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-25T05:04:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.5/6.7 Mellanox mst driver for Mellanox devices"},{"lang":"ja","x_late":"VMware ESXi 6.5/6.7 Mellanox mstドライバー for Mellanoxデバイス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27713","datemodified":"2020-11-24T12:12:04","file_list":["/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip","/cp046337.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/MEL_bootbank_nmst_4.12.0.105-1OEM.650.0.0.4598673.vib","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vmware.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vibs/nmst--7851970169650426567.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/bulletins/MLNX-NMST-ESX-4.12.0.105.xml"],"md5sum":"a4dac3025414956030bb93f29548fe28","name":"cp046337.zip","release":"2020-11-24T12:10:07","revision":"0","sha1sum":"1adcf66eacc405d44a8f08dc4cd4277927193626","size":"27KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.12.0.105-1OEM.650.0.0.4598673"}]}],"id":{"product":"60580eadc28e490db38d80ac26f5a3b8","version":"bc7bb91675cd47cf936e9297df240eb9"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 6.5 and 6.7"},{"lang":"ja","x_late":"net-mstカーネルモジュールドライバーコンポーネント for VMware ESXi 6.5および6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-24T10:28:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for the following adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter&nbsp;(Part Number: P21930-B21)</li>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (Part Number: P11341-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (Part Number: P13188-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (Part Number: P10112-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (Part Number: P21927-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06154-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06250-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (Part Number: P06251-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter (Part Number: P23664-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter (Part Number: P23665-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter (Part Number: P23666-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (Part Number: P25960-B21)</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for the following adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter&nbsp;(Part Number: P21930-B21)</li>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (Part Number: P11341-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (Part Number: P13188-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (Part Number: P10112-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (Part Number: P21927-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06154-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06250-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (Part Number: P06251-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter (Part Number: P23664-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter (Part Number: P23665-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter (Part Number: P23666-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (Part Number: P25960-B21)</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"}],"sw_keys":[{"name":"nmst:4.12.0.105-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"ac963eeb-ed78-4f36-8cc1-29d85f34a0ac","Devices":{"Device":[{"DeviceName":"Firmware for HPE 16GB NVDIMM DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp032704.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-80ad-80ad80ad80ad","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This Linux component provides firmware upgrade for HPE 16GB NVDIMM-N DDR4-2666 Modules."},{"lang":"ja","x_late":"このLinuxコンポーネントは、HPE 16GB NVDIMM-N DDR4-2666モジュール用のファームウェアアップグレードを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Support list :</p>\n\n<p>Linux:</p>\n\n<ul>\n\t<li>SLES12 SP4</li>\n\t<li>RHEL 7.6</li>\n</ul>\n\n<p>VMWare:</p>\n\n<ul>\n\t<li>vSphere 6.7</li>\n</ul>\n"}],"files":[{"bytes":"308388","datemodified":"2019-01-21T05:15:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/CP037532.xml","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/cp032704.compsig","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/cp032704.zip","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037532.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037532.scexe"],"md5sum":"23b4a320f4f6ccbefc31244b62d13692","name":"firmware-nvdimm-16gb-1.04-1.1.x86_64.rpm","release":"2019-01-21T11:16:01","revision":"0","sha1sum":"50c332ec1311af0abde65ebf98ff4311f4b3bc90","size":"301KB","target_guids":["805dd01c-eb5a-1e76-80ad-80ad80ad80ad"],"type_of_change":"1","version":"1.04"}],"id":{"product":"5a879ce939db4665afe30df0d13ef686","version":"6fa995ffd8a64d218bac6b62009f7c50"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command: rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP032706.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-nvdimm-16gb-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP032706.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;# ./hpsetup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;firmware-nvdimm-16gb-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\" style=\"text-decoration-line: none; color: blue;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/x86_64-linux-gnu' の場所へrpm の内容を解凍します。</li>\n\t<li>CP032706.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'firmware-nvdimm-16gb-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：</li>\n</ul>\n\n<p>               # ./CP032706.scexe（'/usr/lib/x86_64-linux-gnu/hp-scexe-compat'で実行）（または）</p>\n\n<p>               # ./hpsetup in the '/usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*' location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id.  これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*'に移動し、ファームウェアをアップデートするために./hpsetupを実行します。'firmware-nvdimm-16gb-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><em><strong>追加情報:</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>HP Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\" style=\"text-decoration-line: none; color: blue;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアを/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるStart.htmlを特定します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - 16GB NVDIMM-N DDR4-2666"},{"lang":"ja","x_late":"Linux用オンラインフラッシュコンポーネント - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-05T10:33:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>Initial release.</p>\n"},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>Initial release.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5960189","datemodified":"2020-11-01T10:25:46","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/CP046209.xml","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/U17_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u17-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046209.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046209.scexe"],"md5sum":"6fb476703c6d5d605e4127ca8ef4f9a4","name":"firmware-system-u17-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-01T10:15:05","revision":"0","sha1sum":"324f2ced8f81a59f2b85b883962ef4a9f8471605","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"662f02886372406fa85fa3e657c2b940","version":"854a25f6db464111a24a513a79e73674"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前の手順で確認したディレクトリに移動し、コマンドプロンプトに‘./hpsetup’を入力するとhpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-01T10:09:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">This version of the System ROM contains the latest support for Red Hat Enterprise Linux 8.x Server. Ver. 2.76_10-21-2019(C) contains updates to the firmware packaging and is functionally equivalent to ver. 2.76_10-21-2019(B) and 2.76_10-21-2019.&nbsp; It is not necessary to upgrade with Revision C if a previous component revision was used to upgrade the firmware to version 2.76_10-21-2019.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-0151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"584260","datemodified":"2021-01-28T09:58:06","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"497550294a00054734b42ea6ab340679","name":"elx-lpfc-kmp-default-12.8.352.11_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-28T09:50:15","revision":"0","sha1sum":"3cf615c75bbfe10b4ff7c90f8c5963421ed86463","size":"570KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"5a529d7f77484eb0a3530f4bebe91103","version":"bb26172401f14b0baaa764ffcc437f2e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 4 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C220A","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13146199","datemodified":"2021-01-21T17:16:21","file_list":["/CP042543_BUILD_11.data","/CP042543.vmexe","/CP042543.vmexe64","/CP042543.vmfile","/CP042543_VMw.zip","/CP042543.xml","/payload.json","/CP042543_VMw.zip/index.xml","/CP042543_VMw.zip/vendor-index.xml","/CP042543_VMw.zip/metadata.zip","/CP042543_VMw.zip/vib20/CP042543/HPE_bootbank_CP042543_2021.02.01.11-7.0.0.15843807.vib","/CP042543_VMw.zip/metadata.zip/vendor-index.xml","/CP042543_VMw.zip/metadata.zip/vmware.xml","/CP042543_VMw.zip/metadata.zip/vibs/CP042543--117487240715132523.xml","/CP042543_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042543_2021.02.01.11-7.0.0.15843807.xml"],"md5sum":"7f02d30228aea68ee34624e7ae9709b5","name":"CP042543.zip","release":"2021-01-21T17:13:05","revision":"0","sha1sum":"f949c40e8db31610787620961ceac053324f52a5","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153","a6b1a447-382a-5a4f-10DF-0720103C8144","a6b1a447-382a-5a4f-10DF-0722103C8144","a6b1a447-382a-5a4f-10DF-0724103C8144","a6b1a447-382a-5a4f-10DF-0720103C220A","a6b1a447-382a-5a4f-10DF-0724103C220A","a6b1a447-382a-5a4f-10DF-0722103C220A"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042543","version":"2021.02.01.11-7.0.0.15843807"}]}],"id":{"product":"798a64591d87417fba658ac00f3833b5","version":"656b4bd2f3054ae6bd7783e8a8f9143d"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-29T06:32:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\"><strong>Firmware</strong></p>\n\n<p><strong>Contains:</strong></p>\n\n<p>CNA (XE100 series) firmware 12.0.1280.5</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<p>UEFI:</p>\n\n<ul>\n\t<li>HPE FlexFabric 20Gb 2-port 650FLB Adapter and HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;does not complete&nbsp;to create boot source on 2nd port</li>\n</ul>\n\n<p>Firmware:</p>\n\n<ul>\n\t<li>Light Emiiting Diode(LED) is in&nbsp;invalid state when disable the port under Unified Extensible Firmware Interface (UEFI)</li>\n\t<li>Duplicate Entries found in firmware report under NIC details for few adaptors.</li>\n\t<li>Full adapter name is not displayed for HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;in some Rom Based Setup Utility (RBSU).</li>\n\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.44_10_29_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.44 (10/29/2020)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33591558","datemodified":"2020-11-06T02:44:49","file_list":["A40_2.44_10_29_2020.signed.flash","A40_2.44_10_29_2020.xml","payload.json"],"md5sum":"ac9d37a077d86f1c95a182252d25921f","name":"A40_2.44_10_29_2020.fwpkg","release":"2020-11-06T02:41:05","revision":"0","sha1sum":"6017adda51fe914872600af5fd569ce891873315","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"1","version":"2.44_10-29-2020"}],"id":{"product":"6f77f9ef4381482fb9f00a79ce325ab3","version":"443fc8af20a24bd4b81e534438641b8a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL385 Gen10（A40）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-21T01:53:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) option for DRAM Burst Refresh Mode to provide mitigation for TRRespass and Targeted Row Refresh exploits. This option should be configured to Disabled to mitigate the TRRespass vulnerability. Setting this option to Disabled may have a minimal impact to system performance. The default setting is Enabled.</p>\n\n<p>Added a new BIOS/Platform Configuration (RBSU) option in the Minimum Processor Idle Power Core C-State setting for C1 State. This option allows for power savings during certain workloads without the performance impacts of C6 State.</p>\n","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where uncorrectable memory errors are seen when running memory intensive workloads with LRDIMMs.</p>\n\n<p>Address an issue that could cause a slight degradation of performance.</p>\n\n<p>Resolved an issue with NVMe hot add or removal which may result in an unrecoverable I/O error reported in the Integrated Management Log (IML).</p>\n\n<p>Addressed an issue where the UEFI Shell command GetPciRom may not display information for PCI expansion device drivers.</p>\n\n<p>Addressed an extremely intermittent issue with AMD Epyc 1st Gen processors that would cause a critical error and system reset.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices. &nbsp;This option would only be used for PCIe Adapters that support his level of bifurcation.&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where the system may hang during boot up after a warm reset from the OS.</p>\n\n<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.</p>\n\n<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22707349","datemodified":"2021-01-28T21:50:41","file_list":["/CP045714_BUILD_2.data","/CP045714.vmexe","/CP045714.vmexe64","/CP045714.vmfile","/CP045714_VMw.zip","/CP045714.xml","/payload.json","/CP045714_VMw.zip/index.xml","/CP045714_VMw.zip/vendor-index.xml","/CP045714_VMw.zip/metadata.zip","/CP045714_VMw.zip/vib20/CP045714/HPE_bootbank_CP045714_HPK4.2-7.0.0.15843807.vib","/CP045714_VMw.zip/metadata.zip/vendor-index.xml","/CP045714_VMw.zip/metadata.zip/vmware.xml","/CP045714_VMw.zip/metadata.zip/vibs/CP045714--609625921730790712.xml","/CP045714_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045714_HPK4.2-7.0.0.15843807.xml"],"md5sum":"1d1a90b0d75336ad0ee59cd07940a369","name":"CP045714.zip","release":"2021-01-28T21:48:05","revision":"0","sha1sum":"ae704c079126427d7d842cd3901555842eae0c51","size":"21MB","target_guids":["4d2340a5-304b-3030-3430-304b5744554b","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3130-3932-304b57445548"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045714","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"116d422873c94edd9b2d0af192be21c4","version":"adaac236f1bf48fc85c244c42b2fede0"},"installation":{"command":"CP040919.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:45:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_29_1016-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 MCX515A-CCAT PCIe3 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter(P31246-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000591</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"5290286","datemodified":"2021-02-25T13:34:31","file_list":["16_29_1016-MCX515A-CCA_HPE_Ax.pldm.signed","16_29_1016-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"5bbe8c65cdb77270f70251eaf8bb147f","name":"16_29_1016-MCX515A-CCA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:31:27","revision":"0","sha1sum":"facf232f37507fbf2e799a792916dfda0c9b8935","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101715900346"],"type_of_change":"1","version":"16.29.1016"}],"id":{"product":"96fe9c5a9b9741d5bcf4ae73623359e0","version":"1a32d84d0b52452dae3dbaacd817b8f3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 MCX515A-CCAT PCIe3 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-05T17:13:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul>\n</ul>\n\n<ul>\n\t<li>Ethernet wqe_too_small Mode<strong>: </strong>New counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>The&nbsp;cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>2 new Mini CQE formats:\n\t<ul>\n\t\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX515A-CCAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16130354","datemodified":"2021-01-28T11:38:42","file_list":["/CP045653_BUILD_6.data","/CP045653.vmexe","/CP045653.vmexe64","/CP045653.vmfile","/CP045653_VMw.zip","/CP045653.xml","/payload.json","/CP045653_VMw.zip/index.xml","/CP045653_VMw.zip/vendor-index.xml","/CP045653_VMw.zip/metadata.zip","/CP045653_VMw.zip/vib20/CP045653/HPE_bootbank_CP045653_HPD4.6-7.0.0.15843807.vib","/CP045653_VMw.zip/metadata.zip/vendor-index.xml","/CP045653_VMw.zip/metadata.zip/vmware.xml","/CP045653_VMw.zip/metadata.zip/vibs/CP045653-7800808895398213361.xml","/CP045653_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045653_HPD4.6-7.0.0.15843807.xml"],"md5sum":"6b8e975ee11565ad3609d0756ab0730f","name":"CP045653.zip","release":"2021-01-28T11:36:05","revision":"0","sha1sum":"155a3a379e53e92cc7c37c1faead82c187bd8042","size":"15MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045653","version":"HPD4.6-7.0.0.15843807"}]}],"id":{"product":"8e3928e62813480eab785be8f1d93fd8","version":"1ad673c88f804f46832bacf6a5a76b71"},"installation":{"command":"CP040513.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:52:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5662056","datemodified":"2020-12-18T02:26:10","file_list":["SignedImageInstaller64.dll","U23_2.90_11_27_2020.signed.flash","cp046423.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"324aec465ef6e85313e7a1ede6dda1cf","name":"cp046423.exe","release":"2020-12-18T02:09:10","revision":"0","sha1sum":"2b55f695572e9bd95ce450d47358b4c89c498e79","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.90_11-27-2020"}],"id":{"product":"7a60cc43d9b440378249c6f65bfb67c0","version":"47f9676217f04501bf174a4063882427"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:&nbsp;</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the&nbsp;Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the&nbsp;Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the&nbsp;Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 </p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。 </p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p style=\"margin-left:0in; margin-right:0in\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen9 (U23) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML30 Gen9 (U23)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-11T06:08:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9).<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381 and INTEL-SA-00389. The Intel microcode patches included in this release are versions 0x000000DC (CPUID 506E3) and 0x0000000DE (CPUID 906E9). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode: 0x000000E2 (CPUID 506E3). This Intel microcode patch provide mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-8696 and CVE-2020-8698. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381. These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"}],"sw_keys":[{"name":"U23","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6236799","datemodified":"2020-10-29T21:27:33","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/CP046199.xml","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/U18_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u18-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046199.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046199.scexe"],"md5sum":"65bf1277827fe4d99ad914efdba27ccb","name":"firmware-system-u18-2.80_2020_10_16-1.1.i386.rpm","release":"2020-10-29T21:18:06","revision":"0","sha1sum":"549b9ad7501c733d6f6f852210623c66ff364242","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"10608c086312418089d4590d5f0549ab","version":"f5161b20738247278904ef7d39a0e505"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL730f/XL740f/XL750f Gen9 (U18) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL730f/XL740f/XL750f Gen9(U18)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-29T21:12:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"}],"sw_keys":[{"name":"U18","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEeD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG1800JFHMH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4874837","datemodified":"2020-12-13T08:39:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/CP045394.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/T14SEeD7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045394.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045394.scexe"],"md5sum":"0331b23a47bb259e0e0eb2abddd65422","name":"firmware-hdd-7fc5497116-HPD7-6.1.x86_64.rpm","release":"2020-12-13T08:26:04","revision":"0","sha1sum":"1fc402b8ffcbd7564b7877490fdc62913b96827f","size":"4MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"07f321e61ae446eba28c1b93476d5170","version":"96d9d87d2a094439a55f380333877c4c"},"installation":{"command":"CP040318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JFHMH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB1000GVYZE、MB2000GVYZF、MB3000GVYZHおよびMB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3401544","datemodified":"2020-12-16T20:01:14","file_list":["cp045537.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNTG4.rel"],"md5sum":"10b4e35d0f02dae70fddb8a7e1a7b3e5","name":"cp045537.exe","release":"2020-12-16T19:37:04","revision":"0","sha1sum":"50b52829f5c754d781eb9995065ff70f1de6e6f6","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d905350ec9f94f94adf8077625981965","version":"307df1bd14324e279f4fd67aee3dbad7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:45:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17401080","datemodified":"2021-01-28T16:20:56","file_list":["/CP045978_BUILD_3.data","/CP045978.vmexe","/CP045978.vmexe64","/CP045978.vmfile","/CP045978_VMw.zip","/CP045978.xml","/payload.json","/CP045978_VMw.zip/index.xml","/CP045978_VMw.zip/vendor-index.xml","/CP045978_VMw.zip/metadata.zip","/CP045978_VMw.zip/vib20/CP045978/HPE_bootbank_CP045978_HPG3.3-7.0.0.15843807.vib","/CP045978_VMw.zip/metadata.zip/vendor-index.xml","/CP045978_VMw.zip/metadata.zip/vmware.xml","/CP045978_VMw.zip/metadata.zip/vibs/CP045978--551824977138812334.xml","/CP045978_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045978_HPG3.3-7.0.0.15843807.xml"],"md5sum":"07707a329d22cbaffe60934b22a14ff3","name":"CP045978.zip","release":"2021-01-28T16:18:10","revision":"0","sha1sum":"009eacc2c430aa5e8923dc8cb57e7fcb401a30a3","size":"16MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP045978","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"df6ba3c2e569412ab3999b9575ddb1d8","version":"45f37b0ce267449e8d1f48fa116d88e7"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-01T07:26:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20050350","datemodified":"2021-01-28T22:11:46","file_list":["/CP045692_BUILD_15.data","/CP045692.vmexe","/CP045692.vmexe64","/CP045692.vmfile","/CP045692_VMw.zip","/CP045692.xml","/payload.json","/CP045692_VMw.zip/index.xml","/CP045692_VMw.zip/vendor-index.xml","/CP045692_VMw.zip/metadata.zip","/CP045692_VMw.zip/vib20/CP045692/HPE_bootbank_CP045692_HPK4.15-7.0.0.15843807.vib","/CP045692_VMw.zip/metadata.zip/vendor-index.xml","/CP045692_VMw.zip/metadata.zip/vmware.xml","/CP045692_VMw.zip/metadata.zip/vibs/CP045692--7396166301620240216.xml","/CP045692_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045692_HPK4.15-7.0.0.15843807.xml"],"md5sum":"050c418159a995b049e62acbbbcd6ec6","name":"CP045692.zip","release":"2021-01-28T22:09:04","revision":"0","sha1sum":"584949c5113904dd97d9aa6069f5bac629b11221","size":"19MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045692","version":"HPK4.15-7.0.0.15843807"}]}],"id":{"product":"496a47bbdbd9415dbba6770e6ba0409b","version":"ff00b14c2dbc426f89fb2c5b34207165"},"installation":{"command":"CP040921.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:27:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_29_1016-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter&nbsp;(P10180-B21)</td>\n\t\t\t<td>22.29.1016</td>\n\t\t\t<td>MT_0000000435</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6176751","datemodified":"2021-02-25T13:15:35","file_list":["22_29_1016-MCX623105AS-VDA_Ax.pldm.signed","22_29_1016-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"md5sum":"b190855f03b0de4a3f7643a0d2c91858","name":"22_29_1016-MCX623105AS-VDA_Ax.pldm.fwpkg","release":"2021-02-25T13:12:05","revision":"0","sha1sum":"47dbf87f5bbdcc5add66e3f11437c788a759115c","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"type_of_change":"1","version":"22.29.1016"}],"id":{"product":"f5b93810cc2347bb802707c26e414376","version":"0996077fc8944fe5b1740c8983cfacfa"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter "}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-11T20:09:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Optimized vDPA performance for PPS in scalability of up to 127 devices per port.</li>\n\t<li>When using a Multi-Host device, the firmware can now discover who is the external SmartNIC host (the Embedded CPU PF (ECPF) ) with the highest index that is responsible for performing offload activities to the adapter card</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Eye-Opening: supported only when using NRZ signal. (Beta)</li>\n\t<li>Option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order. To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command and set DPP relevant attributes.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>Error statistics and reporting for vDPA.</li>\n\t<li>IPv6 TSO offload.&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR</li>\n\t<li>&quot;iperf3&quot; and&nbsp;&quot;iperf3 -l 512&quot;&nbsp; issue fixed&nbsp;from having traffic for virtio hardware offload solution .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) -  MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3014336","datemodified":"2020-12-16T19:06:00","file_list":["cp045541.xml","cpqsetup.exe","payload.json","setup.dll","TTMRNSD4.REL"],"md5sum":"cf712f363a9f80395adcc9c09253b091","name":"cp045541.exe","release":"2020-12-16T18:51:05","revision":"0","sha1sum":"d9a14676e19ac881c5e5d11ac0bf20310039709a","size":"2MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"96868d9680c84d50b81011a5d4811094","version":"b78206ee68034a2fa934cf6d2af09b90"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFDSL and MB4000JFDSN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:46:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"530219","datemodified":"2021-01-28T08:43:39","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1160.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"535e11a08b319d8d313a2a8d970a871b","name":"kmod-elx-lpfc-12.8.352.11-1.rhel7u9.x86_64.rpm","release":"2021-01-28T08:27:06","revision":"0","sha1sum":"fa1fb92ff5fe73154d280eabc994b79405b8f51c","size":"517KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"7cf8ba0f8b844dfea7c2c8e00f2f739c","version":"3f8e9beb42b04e1e9d4e264a15b1a354"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.79"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.79"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"41499194","datemodified":"2020-09-01T05:58:23","file_list":["/CP045810_BUILD_2.data","/CP045810.vmexe","/CP045810.vmexe64","/CP045810.vmfile","/CP045810_VMw.zip","/CP045810.xml","/payload.json","/CP045810_VMw.zip/index.xml","/CP045810_VMw.zip/vendor-index.xml","/CP045810_VMw.zip/metadata.zip","/CP045810_VMw.zip/vib20/CP045810/HPE_bootbank_CP045810_1.79.2-7.0.0.15843807.vib","/CP045810_VMw.zip/metadata.zip/vendor-index.xml","/CP045810_VMw.zip/metadata.zip/vmware.xml","/CP045810_VMw.zip/metadata.zip/vibs/CP045810--8337671217085660801.xml","/CP045810_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045810_1.79.2-7.0.0.15843807.xml"],"md5sum":"ee095829447562b7a0bfb5420592ee49","name":"CP045810.zip","release":"2020-09-01T05:40:06","revision":"0","sha1sum":"521e5b4543997d8f8ee1c9c8e980c25d94fb557d","size":"39MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"1.79","vib_list":[{"name":"CP045810","version":"1.79.2-7.0.0.15843807"}]}],"id":{"product":"a57e8b5260a8406f910d3b1039eaf2da","version":"852d6e24b56d47a0ab7a3e05b8d89c8c"},"installation":{"command":"CP045810.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, for the firmware update to take effect</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-30T17:46:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"914144","datemodified":"2019-10-24T22:59:11","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp039931.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"746411ce6afcc96d398b2e6a03c2d62c","name":"cp039931.exe","release":"2019-10-24T21:44:03","revision":"0","sha1sum":"d8ae6b9adf201fbafe1672a6b0dea792c36bc509","size":"892KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"9017d5d393b24dab905e04b38c0d82f3","version":"e176eabb9c134c88ae1e0d1f591d5735"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers. "}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"7495896","datemodified":"2021-03-18T15:14:33","file_list":["/cp047031.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/vendor-index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/vib20/hpessacli/MIS_bootbank_hpessacli_5.10.45.1-7.0.0.15525992.oem.vib","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vendor-index.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vmware.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/vibs/hpessacli-1653002473151447380.xml","/hpessacli-component_5.10.45.1-7.0.0_17771110.zip/metadata.zip/bulletins/hpessacli-component_5.10.45.1-7.0.0.xml"],"md5sum":"cab759a7fdc45788f118568dff963294","name":"cp047031.zip","release":"2021-03-18T15:12:08","revision":"0","sha1sum":"e38efef5efc3b3e28524b61fe295cee7dcd56a13","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ecc5c305d1"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"hpessacli","version":"5.10.45.1-7.0.0.15525992.oem"}]}],"id":{"product":"91a15c09dbd5425fbdb19fbefcf76977","version":"fc189eb7b32a49e485a32e6a9194d91f"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 7.0 "}],"prerequisites":{"required_diskspace":{"size_kb":"7100"},"supported_devices":[{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"},{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cc","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cd","type":"pci","ven":"103c"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a106159000c0","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a107159000c0","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ce","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cb","type":"pci","ven":"103c"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d661590009d","type":"pci","ven":"8086"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d061590009c","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-193f103c3381","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21be","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c0","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ca","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bd","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c4","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c4","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c9","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c9","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bf","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c7","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c6","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-05T14:04:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpessacli:5.10.45.1-7.0.0.15525992.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli-component:5.10.45.1-7.0.0","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None.</p>\n\n<p><strong>Known Issues:<br />\n     </strong> None</p>"}],"files":[{"bytes":"3634096","datemodified":"2020-12-16T17:03:04","file_list":["cp045554.xml","cpqsetup.exe","HAHC8SDB.rel","payload.json","setup.dll"],"md5sum":"6c6a7c4bf43d5ade1371e28325f12d53","name":"cp045554.exe","release":"2020-12-16T16:54:04","revision":"0","sha1sum":"11778c646c14522815d65821239e372c1a6bdf74","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"f8be51b7e24840dda7b3bf9d2b21fe22","version":"bdc7ccf8a9c6404e91d0116af31ef84d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:51:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892700","datemodified":"2021-01-14T08:29:02","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"1957e512d762d485d15167e516341024","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"44f845ff564809965b476481a94e287f18c82493","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"870976","datemodified":"2021-01-14T08:15:11","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"09216072a0e70cfcbfbe2202bfa800db","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"bb47fb22cf0b2e51bf11aab8289e7e2799a8ab53","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1e813f94062740e78e298970d25a3203","version":"058d8b512c4e4243a6a2850b0e861ad7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045271.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.208"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2152468","datemodified":"2020-11-02T08:37:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/CP045273.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/cp045271.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/cp045271.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.208-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045273.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045273.scexe"],"md5sum":"cdb21581396e6e0c6f9ee93335b46b3c","name":"firmware-dl20ml30gen10sps-05.01.04.208-1.1.x86_64.rpm","release":"2020-11-02T08:30:15","revision":"0","sha1sum":"32ac34a328cd6336d4a69f3d1fee7c612f00194b","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"1","version":"05.01.04.208"}],"id":{"product":"e9b531c475a54ce6b287402b5c425933","version":"bfa6197aff884133a476aeffee4d9c6f"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-18T02:34:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This image contains the latest Intel Server Platform Services (SPS) Firmware which contains mitigations for a variety of security vulnerabilities. The following vulnerabilities have been addressed in this SPS release: CVE-2020-0545 and CVE-2020-0586. These issues are not unique to HPE Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 4 Channel Interface Driver allows software to communicate with the  iLO 4 management controller.  The driver is used by the ProLiant Health Monitor, Insight Management Agents and WBEM Providers, Agentless Management Service, and other utilities."},{"lang":"ja","x_late":"iLO 4 チャネルインターフェイスドライバーは、iLO 4マネジメントコントローラーとの通信を行うことを可能にするソフトウェアです。ドライバーは、ProLiant Health Monitor、Insightマネジメントエージェント、WBEMプロバイダー、Agentless Management Service、およびその他のユーティリティで使用されます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"970816","datemodified":"2019-07-19T13:44:30","file_list":["cp039984.xml","cpqsetup.exe","hpqilo3chif.cab","hpqilo3chif.msi","install.xml","multisetup.dll"],"md5sum":"f613ce12bcf5498234cb4fec367f7408","name":"cp039984.exe","release":"2019-07-19T13:43:02","revision":"0","sha1sum":"aa57be924969f6a134fb71abe5668b9b2237365d","size":"948KB","target_guids":[],"type_of_change":"0","version":"4.1.0.0"}],"id":{"product":"18101e2f386d4a08b577a4dbb3f10bb2","version":"391f0c310c924657a228daaf899c4102"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件放在臨時目錄中，按兩下執行。<p>選擇「Install (安裝)」開始解壓縮至硬碟上的一個臨時位置。   <p>按一下「Install (安裝)」繼續進行驅動程式的安裝。"},{"lang":"en","x_late":"Place the Smart Component in a temporary directory, then double-click it to run.<p>Select \"Install\" to start extracting to a temporary location on the hard drive.   <p>Click the \"Install\" button to perform the driver installation."},{"lang":"ko","x_late":"스마트 구성 요소를 임시 디렉터리에 저장하고 이를 더블 클릭하여 실행합니다.<p>\"설치\"를 선택하여 하드 드라이브의 임시 디렉터리에 압축을 풉니다.   <p>\"설치\" 버튼을 클릭하여 드라이버 설치 작업을 시작합니다."},{"lang":"cn","x_late":"将智能组件置于临时目录中，然后双击运行。<p>选择“安装”，开始提取至硬盘的临时位置。   <p>点击“安装”按钮继续执行驱动程序安装。"},{"lang":"ja","x_late":"Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。   <p>インストールボタンをクリックしてドライバーインストールを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"iLO 4 Channel Interface Driver for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"iLO 4チャネルインターフェイスドライバー for Windows Server 2012 および Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Aligned system and operating system support with the production Service Pack for ProLiant.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Corrected a potential Windows bugcheck 0x50 (PAGE_FAULT_IN_NONPAGED_AREA) that could occur if Windows restarts the driver without unloading it.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpqilo3chif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM4_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2226680","datemodified":"2021-01-29T05:26:16","file_list":["cp043315.xml","cpqsetup.exe","payload.json","setup.dll","UBM4_V1.20.hex.fw"],"md5sum":"0ccbe6739b35deae69b0792ac1ae91ef","name":"cp043315.exe","release":"2021-01-29T05:11:08","revision":"0","sha1sum":"4e8cae96643e96503b058efbf1257c65b25d2a37","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.20"}],"id":{"product":"091f1e01734d4924a66d971602e115bc","version":"3ea923d652164fa5a30668de3dbc85f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM4 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"2048"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-28T14:26:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG2"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG2"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG2"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWTHA、VK000960GWTHB、VK001920GWTHC およびVK003840GWTHDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5677624","datemodified":"2021-01-05T08:32:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/CP046507.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/K401HPG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046507.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046507.scexe"],"md5sum":"b05a7645315bfed5dff16c3f32f5d37a","name":"firmware-hdd-492a9952f6-HPG2-1.1.x86_64.rpm","release":"2021-01-05T08:14:04","revision":"0","sha1sum":"fe674a8c7de99b61c4309c02ba4430cc157c7b30","size":"5MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"0","version":"HPG2"}],"id":{"product":"fde211973c7e4009ac1207f980953529","version":"979326ec59914e4aa9b823e9eeb1fd33"},"installation":{"command":"CP041497.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-05T08:10:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.40 (02/23/2021)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33817686","datemodified":"2021-02-25T07:10:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/A43_2.40_02_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/CP044524.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.40_2021_02_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044524.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044524.scexe"],"md5sum":"1ab272f23905f706e22d3d07ab3acdbb","name":"firmware-system-a43-2.40_2021_02_23-1.1.x86_64.rpm","release":"2021-02-25T07:01:39","revision":"0","sha1sum":"bedd3dc233e25c307e860b2a2343bcfe19f2ed35","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"1","version":"2.40_02-23-2021"}],"id":{"product":"be8e1065c14f4a6883e7804dae8c691e","version":"747eef619d2542c8b3387153b4270db5"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-09T10:06:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) for dual bifurcation (quadfurcation) of PCIe Adapters to the Advanced PCIe Configuration Options. This option will allow a x16 PCIe device to be bifurcated into four x4 devices.  This option would only be used for PCIe Adapters that support his level of bifurcation. <p>Added support to increase the maximum amount of system memory to 8TB.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addressed an issue where the server may encounter an Uncorrectable Machine Check Exception (UMCE) with a Bank of 0x00000005 or an Uncorrectable PCI Express Error with status 0x00040000 or 0x00010000. These errors will result in either an unexpected reset of the server or the server becoming unresponsive (such as Blue Screen with Windows, Purple Screen with VMware, or Kernel Panic with Linux).  This revision of the System ROM includes the latest revision of AMD firmware which addresses this issue.  This issue is not unique to HPE servers.<p>Addressed a rare issue where the system may fail to boot after a warm reset.<p>Addressed an issue where the Advanced Options for Secure Boot failed to export all keys.<p>Addressed an issue where One-Button Secure Erase was not completed when SmartRAID SW RAID support is enabled.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p><p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.</p><p>Added driver and option to enable SmartRAID SW RAID support for direct attached SATA and NVMe drives.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the fan runs at a higher than expected speed after upgrading the firmware of HPE Smart Array E208i or E408i to version 3.0.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300027","languages":[{"lang":"tw","x_late":"驅動程式 ─ 系統"},{"lang":"en","x_late":"Driver - System"},{"lang":"ko","x_late":"드라이버 - 시스템"},{"lang":"ja","x_late":"ドライバ - システム"},{"lang":"cn","x_late":"驱动程序 - 系统"}]}],"description":[{"lang":"en","x_late":"This component provides drivers for HPE NVDIMM-N devices and HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory) installed on systems running Microsoft Windows Server 2012 R2 and 2016."},{"lang":"ja","x_late":"このコンポーネントは、Microsoft Windows Server 2012 R2および2016を実行しているシステムにインストールされているHPE NVDIMM-NデバイスおよびHPE Persistent Memoryデバイス(Intel Optane DC Persistent Memoryを搭載)のドライバを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1015488","datemodified":"2021-02-01T03:15:23","file_list":["cp042922.xml","cpqsetup.exe","hpenvmbus.cat","HpeNvmBus.inf","HpeNvmBus.pdb","HpeNVMBus.sys","HpeNvmBusApi.h","HpeNVMdisk0101.cat","HpeNvmDisk0101.inf","HpeNvmDisk0101.pdb","Hpenvmdisk0101.sys","HpeNvmDsm.h","HpeNvmInstaller.dll","install.xml"],"md5sum":"1b049bf417c034de5f8b35820763448a","name":"cp042922.exe","release":"2021-02-01T03:13:04","revision":"0","sha1sum":"c151b679488b242f311d0255098eb0666d808ba1","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"type_of_change":"1","version":"3.0.2.0"}],"id":{"product":"45e734b674094fd09fe52836988b3440","version":"af8ed8c436a9407b83b20b9744f055d5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Steps to install this Smart Component:</p>\n\n<ul>\n\t<li>If a previous version is already installed, it is recommended to first stop all use of the Persistent Memory devices and disks, and uninstall&nbsp;it from the Control Panel, Uninstall a Program.</li>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the Install button to proceed with the installation.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>このSmartコンポーネントをインストールする手順：</p>\n\n<ul>\n\t<li>以前のバージョンがすでにインストールされている場合は、最初にPersistent Memoryデバイスとディスクの使用をすべて停止し、[コントロールパネル]の[プログラムのアンインストール]からアンインストールすることをお勧めします。</li>\n\t<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>\n\t<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>\n\t<li>[インストール]ボタンをクリックして、インストールを開始してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2012 R2 and 2016"},{"lang":"ja","x_late":"HPE 不揮発性メモリドライバーfor Microsoft Windows Server 2012 R2および2016"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"ACPI\\VEN_ACPI&DEV_0012","target_guid":"","type":"pnp"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-02-15T01:56:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These Non-Volatile Memory&nbsp;drivers enable support for Persistent Memory technology on select HPE Servers running Microsoft Windows Server 2012 R2 and 2016.</p>\n\n<ul>\n\t<li>Added support for HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory), on WS2012R2 and WS2016.</li>\n\t<li>Added support for HPE 16GB NVDIMM devices, on WS2012R2.</li>\n\t<li>Changed block sector size from 512B to 4096B. Old data won&#39;t be accessible and must be backed up first if it needs to be preserved.</li>\n</ul>\n\n<p>For more information about Persistent Memory technology offered on HPE Servers, please consult the following links:</p>\n\n<ul>\n\t<li><a href=\"https://www.hpe.com/us/en/servers/persistent-memory.html\">https://www.hpe.com/us/en/servers/persistent-memory.html</a></li>\n\t<li><a href=\"https://persistentmemory.hpe.com/windows/nvdimm\">https://persistentmemory.hpe.com/windows/nvdimm</a></li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>These Non-Volatile Memory&nbsp;drivers enable support for Persistent Memory technology on select HPE Servers running Microsoft Windows Server 2012 R2 and 2016.</p>\n\n<ul>\n\t<li>Added support for Microsoft virtual NVDIMMs (aka vNVDIMMs) presented by Hyper-V Server 2019, on WS2012R2 and WS2016 guests.</li>\n\t<li>Added support for HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory), on WS2012R2 and WS2016.</li>\n\t<li>Added support for HPE 16GB NVDIMM devices, on WS2012R2.</li>\n\t<li>Changed block sector size from 512B to 4096B. Old data won&#39;t be accessible and must be backed up first if it needs to be preserved.</li>\n</ul>\n\n<p>For more information about Persistent Memory technology offered on HPE Servers, please consult the following links:</p>\n\n<ul>\n\t<li><a href=\"https://www.hpe.com/us/en/servers/persistent-memory.html\">https://www.hpe.com/us/en/servers/persistent-memory.html</a></li>\n\t<li><a href=\"https://persistentmemory.hpe.com/windows/nvdimm\">https://persistentmemory.hpe.com/windows/nvdimm</a></li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HpeNvmInstaller.dll","sw_key_expectedpath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6964574","datemodified":"2020-11-04T21:30:35","file_list":["/CP046157.vmexe","/CP046157.vmfile","/CP046157.xml","/README.txt"],"md5sum":"ade370b8e62b593003c102748c85cb12","name":"CP046157.zip","release":"2020-11-05T03:28:06","revision":"0","sha1sum":"cf0f624e23063deb4ec601492530912c8c82ad6e","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"0efab16660ef48c2b6333da634ea3a4e","version":"efb9f008e6164ee9a1f02ec497517294"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant ML350 Gen9 (P92) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant ML350 Gen9（P92）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T13:36:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"}],"sw_keys":[{"name":"P92","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication."},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13505728","datemodified":"2021-03-18T21:37:35","file_list":["/cp047036.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/index.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/vendor-index.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/MIS_bootbank_hpessacli-5.10.45.1-6.7.0.7535516.oem.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/hponcfg-6.7.0.5.5-0.18.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/ilo_670.10.7.0.4-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/testevent-6.7.0.02-01.00.12.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/bootcfg-6.7.0.02-06.00.14.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/conrep_670.10.7.0.1-6.7.0.7535516.vib","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vendor-index.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vmware.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/hpessacli--6756622436348618397.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/hponcfg--6504653738878051635.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/cru--1581854872647123919.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/ilo-5382991387560295609.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/testevent--7260039959213699592.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/bootcfg-3356455625267296249.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/vibs/conrep-6106948375270150941.xml","/HPE-Utility-Component_6.7.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.7.0.10.7.1-8.zip/bulletins/esxi6.7-util-bundle-10.7.1-8.xml"],"md5sum":"5961033d5395e4362ce838a30cff8e8d","name":"cp047036.zip","release":"2021-03-18T21:35:05","revision":"0","sha1sum":"12a0dd2fd5a348a321f8fa8a05848f0be1bcaed5","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6"],"type_of_change":"1","version":"2021.04.02","vib_list":[{"name":"hpessacli","version":"5.10.45.1-6.7.0.7535516.oem"},{"name":"hponcfg","version":"6.7.0.5.5-0.18.7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"},{"name":"ilo","version":"670.10.7.0.4-1OEM.670.0.0.7535516"},{"name":"testevent","version":"6.7.0.02-01.00.12.7535516"},{"name":"bootcfg","version":"6.7.0.02-06.00.14.7535516"},{"name":"conrep","version":"670.10.7.0.1-6.7.0.7535516"}]}],"id":{"product":"53bb40aec8a14ed088d9afe01e9aba86","version":"e50d5f3453dd405ba2a481a888406327"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Managerの手順に従って、アップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.7 "},{"lang":"ja","x_late":"HPE ユーティリティバンドル Smartコンポーネント for ESXi 6.7 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-08T01:27:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Includes an updated the HPE Smart Storage Administrator CLI&nbsp;(SSACLI).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Pickup latest SIGNED hpssacli.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.7.0.02-06.00.14.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:670.10.7.0.1-6.7.0.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli:5.10.45.1-6.7.0.7535516.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"hponcfg:6.7.0.5.5-0.18.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:670.10.7.0.4-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"testevent:6.7.0.02-01.00.12.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8752052","datemodified":"2020-11-25T08:03:03","file_list":["/CP044794_BUILD_7.data","/CP044794.vmexe","/CP044794.vmexe64","/CP044794.vmfile","/CP044794_VMw.zip","/CP044794.xml","/payload.json","/CP044794_VMw.zip/index.xml","/CP044794_VMw.zip/vendor-index.xml","/CP044794_VMw.zip/metadata.zip","/CP044794_VMw.zip/vib20/CP044794/HPE_bootbank_CP044794_2021.02.01.7-6.7.0.7535516.vib","/CP044794_VMw.zip/metadata.zip/vendor-index.xml","/CP044794_VMw.zip/metadata.zip/vmware.xml","/CP044794_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044794_2021.02.01.7-6.7.0.7535516.xml","/CP044794_VMw.zip/metadata.zip/vibs/CP044794-7270523306043167804.xml"],"md5sum":"8d16c6d97f3efe97500599bd92ef8aab","name":"CP044794.zip","release":"2020-11-25T07:59:05","revision":"0","sha1sum":"dc6a0401d2ed7fabf9770dda31b83cd5f12232b9","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP044794","version":"2021.02.01.7-6.7.0.7535516"}]}],"id":{"product":"8dd88e1b96d74e199d82e65682ededf4","version":"4c166e3167bf463e9a54b3ddfa067b59"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T09:31:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for 8 Gb and 16 Gb&nbsp;products.</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td style=\"width:50px\">UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2572 8Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.03.00</td>\n\t\t\t<td>8.08.231</td>\n\t\t\t<td>7.02</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from the unexpected behavior described in Customer Advisory titled: &ldquo;HPE ProLiant, Synergy and Superdome Flex Host Bus Adapters (HBA) - Certain Fibre Channel HBA Firmware May Cause the Operating System to Halt and Potentially Compromise Filesystem Data Integrity&quot; at the following link:</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></p>\n\n<ul>\n\t<li>Address unexpected behavior when Fibre Channel adapters were simultaneously running traffic to an array which supports 3PAR Persistent Checksum AND another array which is running T10-PI (also known as T10-DIF) or no block checksum technology at all</li>\n\t<li>Fibre Channel adapter firmware versions were not showing up as expected in the AHS log.</li>\n\t<li>Port statistics counters would sometimes not update in the event of Loss of Signal or Loss of Sync</li>\n\t<li>link downs would occur during specific frame sequences used by the HPE XP8 array after array-side link loss</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx4 is the low level driver implementation for the ConnectX®-3 and ConnectX®-3 Pro adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx4は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-3およびConnectX®-3 Proアダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2798457","datemodified":"2020-11-24T07:55:32","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip","/cp046261.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-rdma-1214697530.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-en-1132928091.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-core--114843923.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_core-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_en-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_rdma-3.16.70.2.xml"],"md5sum":"8e137dace023b758639d11e15d219cdc","name":"cp046261.zip","release":"2020-11-24T07:53:10","revision":"0","sha1sum":"fcbe6c42a7eeafff1b7d123fe1e5504d5453e6d9","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-core","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-en","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-rdma","version":"3.16.70.2-1OEM.650.0.0.4598673"}]}],"id":{"product":"4fdb2c37f619467eb44cb380a68bf092","version":"26a0e9fca5e04cc2bbfae7a4598f52e4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx4_en Driver Component for VMware 6.5"},{"lang":"ja","x_late":"nmlx4_enドライバーコンポーネント for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-core:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-en:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.54.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.54.4"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.2836.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"本套件包含可升級 HPE Intel 乙太網路網路卡 ROM 映像的公用程式和二進位檔，適用於 Linux x86_64 平台。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE Intel Ethernet NICs ROM 이미지를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包包含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE Intel以太网卡ROM映像。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>Single NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361i Adapter</td>\n\t\t\t<td>8000106F</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361T Adapter</td>\n\t\t\t<td>80000F91</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 363i Adapter</td>\n\t\t\t<td>80000D00</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Communication Board</td>\n\t\t\t<td>80000EBF</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Adapter</td>\n\t\t\t<td>8000105E</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td>\n\t\t\t<td>80001060</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366T Adapter</td>\n\t\t\t<td>8000105F</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368i Adapter</td>\n\t\t\t<td>800027FA</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 369i Adapter</td>\n\t\t\t<td>800027FB</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</td>\n\t\t\t<td>80000838</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560SFP+ Adapter</td>\n\t\t\t<td>80000835</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561T Adapter</td>\n\t\t\t<td>80000636</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</td>\n\t\t\t<td>800005B6</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568i Adapter</td>\n\t\t\t<td>800027FC</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td>\n\t\t\t<td>800027F8</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 563i Adapter</td>\n\t\t\t<td>800035C0</td>\n\t\t\t<td>1.1375.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td>\n\t\t\t<td>80009655</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td>\n\t\t\t<td>8000137D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.4</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td>\n\t\t\t<td>800095AA</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562T Adapter</td>\n\t\t\t<td>8000137C</td>\n\t\t\t<td>1.2836.0</td>\n\t\t\t<td>10.54.4</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18 &amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n\n<p>The combo image v1.1375.0 includes: Boot Agent: 1GbE - v1.5.72, 10GbE - v2.3.46, 40GbE - v1.0.21 &amp; UEFI Drivers: 1GbE - v6.9.13, 10GbE - v5.0.20, 40GbE - v1.5.14</p>\n\n<p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p>\n"}],"files":[{"bytes":"11099031","datemodified":"2021-01-21T15:33:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/CP045035.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/CP045035.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_361T_H65030-003_2.25_80000F91.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366FLR_G41713-00x_80001060.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366FLR_G41713-00x_80001060.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366T_Quad_H73104-00x_8000105F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366T_Quad_H73104-00x_8000105F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p10_800027FB.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_80000838.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_80009655.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_562FLR-T_B0_AT2_3p10_8000137D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_562SFP_DP_H44490-000_800095AA.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_3p10_8000137C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_5p10_800027FC.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_5p10_800027F8.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1514_P23_NCSI_5p10_800027FA.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.21.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045035.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045035.scexe"],"md5sum":"5b1e11b419af45350bede2c3be592ae2","name":"firmware-nic-intel-1.21.6-1.1.x86_64.rpm","release":"2021-01-21T15:23:06","revision":"0","sha1sum":"68a4e013fef1ab04491c90efa6b7ee1e4a4f948b","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"0","version":"1.21.6"}],"id":{"product":"d8c86b5c3ce7444dbebf7bd215bf1a32","version":"c967b9da294b44c9b2454162a3a43d32"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP045035.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP045035.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP045035<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP045035.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 4-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"HPE Intel 線上韌體升級公用程式 (適用於 Linux x86_64)"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE Intel 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an WOL issue that system wakes up automatically if any magic packet being sent before system was shut down.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Systems Insight Display (SID) modul is green when there&#39;s no Network connection.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:intel_nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 64-bit to enable the HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"734770","datemodified":"2020-12-02T16:56:41","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"f1190631efe89081def3a589626b686d","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles12sp4-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"2799d520bd3323269e33b9c822bd7e59ce6907e7","size":"717KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"741637","datemodified":"2020-12-02T17:04:00","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"7943ba2cb17e19f007a9687eef9d0847","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles12sp5-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"8e41553b3f29c8ad37082e50bc9fe20d1a02811d","size":"724KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"849f086e086c48be8b248502b935c97a","version":"81118136e9504f57bd718b3fc3fca469"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a controller Driver for 64-bit SUSE LINUX Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T13:14:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8041995","datemodified":"2021-03-15T22:39:58","file_list":["/CP047164.vmexe","/CP047164.vmexe64","/CP047164.vmfile","/CP047164.xml","/README.txt"],"md5sum":"d04e1b0e3950120f43eecaa5d9e095fe","name":"CP047164.zip","release":"2021-03-16T03:37:05","revision":"0","sha1sum":"f2b764353e74d73ba82dbdd7ad63f08436485342","size":"7MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"77de034d485c4fb1942e2bf46cd3c50b","version":"dda393c5c45c4fa5a4fce7e43bc8d504"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.</p>\n\n<p>The minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp; SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。</p>\n\n<p>5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant DL580 Gen9 (U17) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-16T03:29:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the component packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision (B) if a previous component revision was used to upgrade the firmware to 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000016 (CPUID 306F4) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"}],"sw_keys":[{"name":"U17","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9061264","datemodified":"2020-11-03T03:43:51","file_list":["cp045749.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_2.20_10_27_2020.signed.flash"],"md5sum":"d64ad2a13c842b875d7f2bd51fae68e9","name":"cp045749.exe","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"78211ccf06f5a5f6ae1e671c2850ee1c02e4ab08","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"321dd379dd1a436ab919b4529b332ece","version":"a51c7b7d3b844340a7ee56abd94485ea"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB001000GWCBCおよびMB002000GWCBDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     HPG4<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3991984","datemodified":"2020-12-17T08:28:57","file_list":["cp045514.xml","cpqsetup.exe","payload.json","setup.dll","WRN620G6.rel"],"md5sum":"358b420189eeed74a1740a225cf06f42","name":"cp045514.exe","release":"2020-12-17T08:20:09","revision":"0","sha1sum":"97c5b32ece8c522d0e9d9ae2186defe440eaa5a3","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"39fa471cea234b3883e794de990ad252","version":"3ce04928439d432f9674b31804140b14"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:37:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPEService Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"31530472","datemodified":"2021-01-28T15:23:34","file_list":["archives/","archives/hpoa350.bin","cp046217.xml","cp_data.xml","oa497.bin","oaupgrade.exe"],"md5sum":"846c6f4a9c96f5d7fa920fc4783acc15","name":"cp046217.exe","release":"2021-01-28T15:19:06","revision":"0","sha1sum":"8290f2d8103f5c74631967a529bfdc8f0d174ad9","size":"30MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"771e2c2febad408da9107df2836d8e4d","version":"70086c3a4faf40419d579e87c25c79aa"},"installation":{"command":"oaupgrade.exe","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a stand alone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a stand alone component</strong></p>\n\n<p>This smart component is a self-extracting executable. The smart component unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.</p>\n\n<p>The general command line syntax for this smart component is</p>\n\n<p><br />\n&nbsp;&nbsp;&nbsp;cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</p>\n\n<p><br />\nwhere cpxxxxxx.exe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul dir=\"ltr\">\n\t<li>&nbsp;/target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The netAddress parameter is the IP address or DNS name of the OA to target.&nbsp; This should be the Active OA if two OA&rsquo;s are in an enclosure.&nbsp; There is a space between the /target and the netAddress parameter.</li>\n\t<li>&nbsp;/user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The username is the userid to use when attempting to login to the OA.&nbsp; There is a space between the /user and the username parameter.</li>\n\t<li>&nbsp;/passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA.&nbsp; There is a space between the /passwd and the password parameter.</li>\n\t<li>&nbsp;/s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;The silent option will silently install the firmware, if needed.</li>\n\t<li>&nbsp;/f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>&nbsp;/logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; This optional parameter is used to redirect the output from the OA flash utility to a different directory&nbsp;than the default location of %SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\&lt;netAddress&gt;. The redirected location is &lt;path&gt;\\hp\\log\\&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>&nbsp;Download the smart component file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>&nbsp;Execute cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are :</p>\n\n<ul>\n\t<li>&nbsp;0&nbsp; &nbsp;&nbsp; Success</li>\n\t<li>&nbsp;1&nbsp;&nbsp; &nbsp; Reserved</li>\n\t<li>&nbsp;2&nbsp;&nbsp; &nbsp;&nbsp;Upgrade is not needed because firmware version is current</li>\n\t<li>&nbsp;3&nbsp;&nbsp; &nbsp; Upgrade is not needed because newer firmware version is present</li>\n\t<li>&nbsp;4&nbsp;&nbsp; &nbsp; Target not found</li>\n\t<li>&nbsp;5&nbsp;&nbsp;&nbsp; &nbsp;User terminated session</li>\n\t<li>&nbsp;6&nbsp;&nbsp;&nbsp;&nbsp; Incorrect parameter</li>\n\t<li>&nbsp;7&nbsp;&nbsp;&nbsp;&nbsp; General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上にあるHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSmartコンポーネントは、自己解凍型実行可能ファイルです。Smartコンポーネントは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。</p>\n\n<p>このSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p><br />\n   cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</p>\n\n<p><br />\ncpxxxxxx.exeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul dir=\"ltr\">\n\t<li> /target <netAddress>           netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。  1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。  /targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li> /user <username>               ユーザー名はOAにログインするときに使用するユーザーIDです。  /userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li> /passwd <password>            パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。  /passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li> /s[ilent]                                サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li> /f[orce]                                forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li> /logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所%SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\<netAddress>ではなく、異なるディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>\\hp\\log\\<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li> アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSmartコンポーネントファイルをダウンロードします。</li>\n\t<li> Execute cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li> 0 成功</li>\n\t<li> 1 予約済み</li>\n\t<li> 2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li> 3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li> 4  ターゲットが見つからない</li>\n\t<li> 5     ユーザーによって中止されたセッション</li>\n\t<li> 6     パラメーターが不正</li>\n\t<li> 7     一般障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Windows"},{"lang":"ko","x_late":"Windows용 온라인 HPE BladeSystem c-Class Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Windows 的联机 HPE BladeSystem c-Class Onboard Administrator 固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages.</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name</strong> (CN) field and IP address in <strong>SAN </strong>field.</li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers.</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>.Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on&nbsp;OA version 4.90 and less than 4.90. This issue is caused by the introduction of new&nbsp;&nbsp; signature in the iLO5 firmware version 2.10.</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.56(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"10257599","datemodified":"2018-12-12T14:13:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/CP037766.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/Talladega-Release-1.56-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/libsetup2.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/setup2","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/storcli-1.25.12-1.noarch.rpm","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/supplement","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037766.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037766.scexe"],"md5sum":"f616851c186ef1fd361cba750a5310bc","name":"firmware-smartarray-815b1ae26d-1.56-3.1.x86_64.rpm","release":"2018-12-12T20:09:13","revision":"0","sha1sum":"f480236b56ed307607026b69f1ad7a294cc3c8af","size":"9MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56"}],"id":{"product":"8ab91a2b5ff149e8a59b3d86d5fbcc3d","version":"a77e6866a83f46a1a35d16f76a8417ba"},"installation":{"command":"CP037766.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037766.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-815b1ae26d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037766.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-815b1ae26d-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - HPE Apollo 45xx Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-03T16:52:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"tw","x_late":"Smart Storage Administrator Diagnostic Utility CLI 是適用於 Smart Array 控制器及任何受支援裝置之基於命令列的磁碟組態程式，包括為受支援的磁碟機提供 SmartSSD 磨損測量計資訊。"},{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."},{"lang":"ko","x_late":"스마트 스토리지 관리자 진단 유틸리티 CLI는 스마트 어레이 컨트롤러 및 지원되는 장치에 대한 명령줄 기반의 디스크 구성 프로그램이며 지원되는 드라이브에 대한 SmartSSD Wear Gauge 정보도 제공합니다."},{"lang":"cn","x_late":"Smart Storage Administrator Diagnostic Utility CLI 是一款面向智能阵列控制器和所有支持设备的基于命令行的磁盘配置程序，包括为支持的驱动器提供 SmartSSD Wear Gauge 信息。"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility CLIは、サポートされたドライブのSmartSSD Wear Gauge情報の提供を含む、Smartアレイコントローラーおよびサポートされたデバイスのためのコマンドラインベースのディスク構成プログラムです。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Running SSADUCLI<br />\n------------------------------------------------------------------------<br />\nTo run the command-line application:&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />\n&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p>\n\n<p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />\n&nbsp;&nbsp;<br />\n&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\nAdditional Notes<br />\n----------------<br />\nBoth the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />\n&nbsp; (ZIP) format.</p>\n\n<p>The diagnostic report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />\n&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />\n&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />\n&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />\n&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p>\n\n<p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HP Smart<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p>\n\n<p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p>\n\n<p>The SmartSSD wear gauge report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p>\n\n<p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />\n&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p>\n\n<p>Known Issues<br />\n------------<br />\n* When installing the 32-bit version of SSADUCLI on a system that has a<br />\n&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />\n&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />\n&nbsp; installation to fail.</p>\n"}],"files":[{"bytes":"3341304","datemodified":"2021-02-15T15:56:45","file_list":["cp041184.xml","cpqsetup.exe","genericmsi.dll","SSADU510440_X64.msi"],"md5sum":"f225426e3a40a1b01b33307a9b702be4","name":"cp041184.exe","release":"2021-02-15T15:55:04","revision":"0","sha1sum":"36be2e877844d35a006056719c937f54ec1d4938","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"type_of_change":"0","version":"5.10.44.0"}],"id":{"product":"3ac61ed209fd49fb908341fa7b77c3ea","version":"b59d963226f64c51b1431817280b8466"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Adding support&nbsp;to the HPE&nbsp;SR Gen10 Plus&nbsp;Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"594372","datemodified":"2021-01-28T09:14:48","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-240.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"3cdbc079056ad09512d950f9629e714b","name":"kmod-elx-lpfc-12.8.352.11-1.rhel8u3.x86_64.rpm","release":"2021-01-28T09:04:06","revision":"0","sha1sum":"b35ed58f18a37a2d558049992f66e59b123593df","size":"580KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"a1969a6dced74b848f7c8392464ddc8c","version":"d29fc94b9f5c4c378c479ec8f37909e2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-11.2.xxx.x_3.0.76_0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.6.275.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4216191","datemodified":"2021-03-08T18:14:03","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"203b91ac5167e02c38e1de393b0cc8cc","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"8d5cc710beefa743ae2adda67fa78b8f8a0360c8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4099344","datemodified":"2021-03-08T18:15:23","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"a339e4390c75808ef95dae101c437133","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"c8ddbf34e027cc801dcab7917bd100c63f5268fb","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"5eee6ab16a2542c6ab8115b98b119c8f","version":"de1c9c07fe0f4f4d834b26da4175dabe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Windows. Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows用Marvell FastLinQ 10/25/50 GbEドライバーのドライバーが含まれています。Windows Server 2016およびWindows Server 2019"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>Windows qevbd Driver is 8.55.5.0</li>\n\t<li>Windows qend Driver is 8.55.3.0</li>\n\t<li>Windows qefcoe Driver is 8.55.2.0</li>\n\t<li>Windows qxdiag Driver is 8.14.0.0</li>\n\t<li>Windows qeois Driver is 8.53.51.0</li>\n</ul>\n"}],"files":[{"bytes":"6305392","datemodified":"2021-01-08T10:11:16","file_list":["cp044988.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"md5sum":"b404b4720186f2dffa644e6edcdd07a4","name":"cp044988.exe","release":"2021-01-08T09:51:09","revision":"0","sha1sum":"d153305d7978b79ac8ceb2ef18965f33a6562b13","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"0","version":"8.55.5.0"}],"id":{"product":"8484f11834644aea8a2a14d1d0d58403","version":"4cfe13454e1c4df894f88d52890c10c7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"Marvell FastLinQ 10/25/50 GbEドライバー for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixes the Virtual Function (VF) sleep duration on the channel while it waits for Physical Function(PF) response.</li>\n\t<li>This product correct an issue which System crashed when Single Root I/O Virtualization(SR-IOV) enabled on few partitions and disabled on few partitions using OneView.</li>\n\t<li>This product correct an issue which operating system boot failure after update Firmware to 08.50.27.</li>\n\t<li>This product correct an issue which System crashed is seen while upgrading drivers on enabled Network Partitioning (NPAR) and Single Root I/O Virtualization(SR-IOV) with enterprise data Center mode.&nbsp;</li>\n\t<li>This product correct an issue which Virtual Machines (VMs) crash randomly upon advanced property disable/enable with Max virtual functions (VFs) enumerated on all Physical Functions(PFs).</li>\n\t<li>This product correct an issue which System crashed seen while disabling Network Driver Interface Specification (NDIS) driver while running &nbsp;RoCEv2 IPv6 traffic on Management OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an Wake-on-LAN (WoL) function unavailable.</li>\n\t<li>This product correct high CPU usage with Virtual Machine Multiple Queues (VMMQ).</li>\n\t<li>This product addresses a BSOD seen when using the netsh utility to configure global RSS.</li>\n\t<li>This product correct an issue which fixes BSOD in case of NicSwitch and send NBL has vport id which exceeds max vports capability.</li>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen where an SR-IOV virtual function to assign while installing driver.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"qevbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD8"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5444596","datemodified":"2020-12-13T14:35:32","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/CP045452.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/SAVNGSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045452.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045452.scexe"],"md5sum":"d7f21d7354899bdfc6fe2aa0721be720","name":"firmware-hdd-b04257b77b-HPD8-6.1.x86_64.rpm","release":"2020-12-13T14:24:09","revision":"0","sha1sum":"61fad4e9e3eabef538b54817043095fe50408b9b","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"0","version":"HPD8"}],"id":{"product":"4cf79b782386458fa01aea2ca94f4962","version":"28f66a2d6f1d44b59d144e5dee50c4c1"},"installation":{"command":"CP040271.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic,&nbsp;version 1.0.57.0</li>\n\t<li>qfle3i,&nbsp;version 1.1.5.0</li>\n\t<li>qfle3f,&nbsp;version 1.1.15.0</li>\n\t<li>qfle3 version 1.1.12.0</li>\n</ul>\n"}],"files":[{"bytes":"1382880","datemodified":"2021-01-18T03:42:29","file_list":["/cp046404.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.12.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.57.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.15.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3-711707153.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qcnic--1732253406.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3f-504550429.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.57.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.15.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.12.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"48056077a73c7dc6e99e287a6047ebb9","name":"cp046404.zip","release":"2021-01-18T03:41:05","revision":"0","sha1sum":"805e408454e67aad00dcd64cc3d28ee46192f8b6","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qcnic","version":"1.0.57.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.15.0-1OEM.650.0.0.4598673"},{"name":"qfle3","version":"1.1.12.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"5cd2c31f18d541c09e937a83715365ee","version":"a2871e4bb75b4433a7b38b1a5e50eaa7"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-08T09:54:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where Purple Screen Of Death(PSOD) when ethernet link connected to 533FLR-T/536FLR-T Adapters.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an incorrect MTU value displayed by the ESXCLI tool.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qcnic:1.0.57.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.15.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.12.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD8"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp; </strong>Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3859568","datemodified":"2020-12-17T12:28:49","file_list":["cp046269.xml","cpqsetup.exe","payload.json","setup.dll","SKESTED8.rel"],"md5sum":"28e38c6c73fd95de7e8b385f3427db5d","name":"cp046269.exe","release":"2020-12-17T12:15:09","revision":"0","sha1sum":"3587da7097b0a706f3c7622ed6dd3c432fd56041","size":"3MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"308794285e444711a0eb3833d54eb10e","version":"7e4baf405fae43b691ff59270bb5c701"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-14T20:56:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD2"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n     </strong>Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPD2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <strong> </strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4046560","datemodified":"2020-12-11T20:53:16","file_list":["cp045585.xml","cpqsetup.exe","payload.json","SCIMARRNESD2.rel","setup.dll"],"md5sum":"2e4350084461842d9266fd5229885e57","name":"cp045585.exe","release":"2020-12-11T20:33:04","revision":"0","sha1sum":"0602828d2a78c779e3969f3290a3341c01625b18","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"8e4da865e5b44ea38e4b650ce9a93715","version":"139146773b66413e911e830525227a74"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:04:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD7"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD7"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD7"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD7"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD7"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD7"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD7"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD7"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD7"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD7"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD7"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD7"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD7"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV\n"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC およびMO001920JWWWV\n"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\nOnline&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4827739","datemodified":"2020-12-13T15:51:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/CP045466.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/TAPM5ALLHPD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045466.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045466.scexe"],"md5sum":"d002ace943a003ba032dfb7836fe2680","name":"firmware-hdd-9ad359dac1-HPD7-6.1.x86_64.rpm","release":"2020-12-13T15:40:04","revision":"0","sha1sum":"0f1fbfb5fed010fad8c7ac4490ad4e3ac4c6f25d","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"c47b4b11bb744418a62b9ae668fd0ea6","version":"dbbb547126dd49c9a172e29ce2c6aa71"},"installation":{"command":"CP040601.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:19:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEFNAおよびMB6000GEFNBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) -  MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features for :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n     </strong> None</p>"}],"files":[{"bytes":"3431712","datemodified":"2020-12-16T18:33:57","file_list":["cp045544.xml","cpqsetup.exe","payload.json","setup.dll","SMKRATG6.rel"],"md5sum":"7ea66a8269863cacbe6c42e4a5a9709c","name":"cp045544.exe","release":"2020-12-16T18:22:05","revision":"0","sha1sum":"acc131d12ceb90bf72eabb85d64323c9512128da","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"edc1764ca6d04bbd943cd314f29904b6","version":"09cc22faf5214b179feab91b33133b7b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEFNA and MB6000GEFNB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:47:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8732248","datemodified":"2021-03-08T18:37:56","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"4cfe0f7d92403a2a0fe38025cc8fac4f","name":"kmod-netxtreme2_bl-7.14.76-1.rhel8u2.x86_64.rpm","release":"2021-03-08T18:16:08","revision":"0","sha1sum":"8e43139cbbf013f1afff149852266873b286df5c","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"8930619","datemodified":"2021-03-08T18:36:21","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"36468e2ef129d637f0fb48a95591ad77","name":"kmod-netxtreme2_bl-7.14.76-2.rhel8u3.x86_64.rpm","release":"2021-03-08T18:16:08","revision":"0","sha1sum":"6e4e0801dcc0f891342da50b07b1889032192f5a","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"b3f391bd1aa44685b17f74a3d4ddf32c","version":"04113cbd23174aefba554409620997fd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers correct an issue where iSCSI target discovery fails to complete when booting from SAN or a local HD.</p>\n\n<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2012 R2, Windows Server 2016, and Windows Server 2019 for the HPE Smart Array S100i SR Gen10 SW RAID"},{"lang":"ja","x_late":"このドライバーは、Windows Server 2012 R2、Windows Server 2016およびWindows Server 2019 for the HPE SmartアレイS100i SR Gen10 SW RAIDをサポートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1636712","datemodified":"2020-03-18T13:08:58","file_list":["cp043250.xml","cpqsetup.exe","generic.dll","install.xml","smartdq.cat","SmartDQ.inf","SmartDQa.sys","SmartDQco002.dll","SmartDQp.sys","SmartDQr.sys"],"md5sum":"80ade24f28d3f53005ee8d2f2c4bfab8","name":"cp043250.exe","release":"2020-03-19T00:00:00","revision":"3","sha1sum":"cd635362bd99b7b7c0c30a11e782c40d01f8de3d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59"],"type_of_change":"1","version":"106.12.6.0"}],"id":{"product":"d2e7aa5024a34aef908b398a3c4e0625","version":"a1e6ea89c5c54463b0eaa2d4888cdf11"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n\n<p><strong>注: </strong>Microsoft kb #2031031について(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>)、 ユーザーはUSBインストールが終わるまではUSBを削除したり、取り外したりすることはできません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2012 R2, Windows Server 2016, and Windows Server 2019"},{"lang":"ja","x_late":"HPE SmartアレイS100i SR Gen10 SW RAIDドライバーfor Windows Server 2012 R2、Windows Server 2016およびWindows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Storage Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-28T15:46:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for AMD.</p>\n","latest_fixes_x_late":"<p>Addressed an issue where the HPE Smart Array s100i Software RAID may experience potential data inconsistency during initial configuration or operation of a RAID volume configured in RAID 0/1/5/10 Fault Tolerant Modes.&nbsp;</p>\n\n<p style=\"margin-left:48px\">This issue does not impact systems configured in other RAID configurations such as RAID 0 or 1. This issue does not impact systems that have not enabled Smart Array s100i support.</p>\n\n<ul>\n\t<li>For additional information, reference&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00097734en_us\" style=\"color:#0563c1; text-decoration:underline\" target=\"_blank\">Customer Bulletin a00097734en_us</a>.</li>\n</ul>\n\n<p style=\"margin-left:48px\"><strong>IMPORTANT INFORMATION:</strong></p>\n\n<ul>\n\t<li>An array configured with a single RAID 0 logical drive is NOT affected.</li>\n\t<li>An array configured with a single RAID 1 logical drive is NOT affected.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Added support for AMD.</p>\n","curr_fixes_x_late":"<p>Addressed an issue where the HPE Smart Array s100i Software RAID may experience potential data inconsistency during initial configuration or operation of a RAID volume configured in RAID 0/1/5/10 Fault Tolerant Modes.&nbsp;</p>\n\n<p style=\"margin-left:48px\">This issue does not impact systems that have not enabled Smart Array s100i support.</p>\n\n<ul>\n\t<li>For additional information, reference&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00097789en_us\">Customer Bulletin a00097789en_us. </a></li>\n</ul>\n\n<p style=\"margin-left:48px\"><strong>IMPORTANT INFORMATION:</strong></p>\n\n<ul>\n\t<li>An array configured with a single RAID 0 logical drive is NOT affected.</li>\n\t<li>An array configured with a single RAID 1 logical drive is NOT affected.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"","value":"HPE Apollo k6000 Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"SmartDQa.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD8"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SATA drive models: MB008000JWJRQ and MB006000JWJRP "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB008000JWJRQおよびMB006000JWJRP "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16137066","datemodified":"2021-01-28T17:28:44","file_list":["/CP046240_BUILD_3.data","/CP046240.vmexe","/CP046240.vmexe64","/CP046240.vmfile","/CP046240_VMw.zip","/CP046240.xml","/payload.json","/CP046240_VMw.zip/index.xml","/CP046240_VMw.zip/vendor-index.xml","/CP046240_VMw.zip/metadata.zip","/CP046240_VMw.zip/vib20/CP046240/HPE_bootbank_CP046240_HPD8.3-7.0.0.15843807.vib","/CP046240_VMw.zip/metadata.zip/vendor-index.xml","/CP046240_VMw.zip/metadata.zip/vmware.xml","/CP046240_VMw.zip/metadata.zip/vibs/CP046240-6776375106679808859.xml","/CP046240_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046240_HPD8.3-7.0.0.15843807.xml"],"md5sum":"5341a4e4a631b438024177ebb046ffef","name":"CP046240.zip","release":"2021-01-28T17:26:04","revision":"0","sha1sum":"fa6e4ee9e84264bbe3f1c8ec577c5eeea9daf468","size":"15MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP046240","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"5e76fbf672b8432aa6436d748dacb463","version":"ef11319d45874ea5aaee0661212f8edc"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWJRQおよび MB006000JWJRP ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-05T15:38:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."},{"lang":"ja","x_late":"HPE SmartアレイイSRベント通知サービスは、HPE SmartアレイSRコントローラードライバーを使用しているシステムで、64ビットMicrosoft Windows Serverシステムイベントログへのイベント通知をサポートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"700776","datemodified":"2021-02-19T05:00:05","file_list":["cp045133.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"md5sum":"3d015543e48cc72b776d26812693edc1","name":"cp045133.exe","release":"2021-02-19T04:58:04","revision":"0","sha1sum":"6abf80cdba2cae1591a5be43079c670470df6a97","size":"684KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"type_of_change":"1","version":"1.2.1.65"}],"id":{"product":"ccde97956825448f97ee8427bc2eccdb","version":"1372fc9624c54e198d6c2c7b19848bb0"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"62.0.28.64","description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"},{"lang":"ja","x_late":"Windows Server 64ビットEditions向けHPE SmartアレイSRベント通知サービス "}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-07T08:52:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Corrected unknown or unrecognized class information in the System Event Log.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed for the version information</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"hpepqiesrv.exe","sw_key_expectedpath":"%programfiles%\\hpe\\hpepqiesrv"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD3"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG000600JWFUVおよびEG001200JWFVA ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWFUV and EG001200JWFVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15914902","datemodified":"2021-01-27T11:34:18","file_list":["/CP045606_BUILD_4.data","/CP045606.vmexe","/CP045606.vmexe64","/CP045606.vmfile","/CP045606_VMw.zip","/CP045606.xml","/payload.json","/CP045606_VMw.zip/index.xml","/CP045606_VMw.zip/vendor-index.xml","/CP045606_VMw.zip/metadata.zip","/CP045606_VMw.zip/vib20/CP045606/HPE_bootbank_CP045606_HPD3.4-7.0.0.15843807.vib","/CP045606_VMw.zip/metadata.zip/vendor-index.xml","/CP045606_VMw.zip/metadata.zip/vmware.xml","/CP045606_VMw.zip/metadata.zip/vibs/CP045606-4384123425541355976.xml","/CP045606_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045606_HPD3.4-7.0.0.15843807.xml"],"md5sum":"cf60aa5871f54e1294ab6cdf6293305d","name":"CP045606.zip","release":"2021-01-27T11:31:26","revision":"0","sha1sum":"bbdd0c8fbc9cacfef3f3d9f55482345dcc8e6982","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"0","version":"HPD3","vib_list":[{"name":"CP045606","version":"HPD3.4-7.0.0.15843807"}]}],"id":{"product":"239d1dd26f2c4614bfcd9033d0a83734","version":"337d9c52c43747febf42f57b47fa2e5e"},"installation":{"command":"CP040635.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:12:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for SUSE Linux Enterprise Server 15 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、64-bit SUSE LINUX Enterprise Server 15用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"1019771","datemodified":"2020-06-29T09:59:22","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"2d7e9f882e69a66b7b1eae514f21f165","name":"hpdsa-kmp-default-1.2.10-182.sles15sp2.x86_64.rpm","release":"2020-06-29T09:44:04","revision":"0","sha1sum":"830e146c7f71eb47a8ffe87b883a54863e1a1277","size":"0MB","target_guids":[],"type_of_change":"1","version":"1.2.10-182"},{"bytes":"1015664","datemodified":"2020-06-29T09:54:46","file_list":["./etc/dracut.conf.d/hpdsa.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hpdsa.ko","./usr/share/smartupdate/hpdsa-kmp-default/component.xml"],"md5sum":"ff2221b9e87ceb5e09c79d6a168de600","name":"hpdsa-kmp-default-1.2.10-182.sles15sp1.x86_64.rpm","release":"2020-06-29T09:44:04","revision":"0","sha1sum":"4341b24d5347743907592bd4601481556b2cc3da","size":"0MB","target_guids":[],"type_of_change":"1","version":"1.2.10-182"}],"id":{"product":"f0faaea8688741debca7931ae839b647","version":"c7591184ddea4b9986320216bc40df2e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">注記：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e hpdsa-kmp-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"lang":"ja","x_late":"SUSE LINUX Enterprise Server 15(64-bit)用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-27T22:00:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for SUSE Linux Enterprise Services15 SP1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Support for SUSE Linux Enterprise Service 15.2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hpdsa-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2012 R2用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1943776","datemodified":"2021-02-09T07:37:01","file_list":["cp045130.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"43e5b5f6d99c639195861c9824d6e03a","name":"cp045130.exe","release":"2021-02-09T07:22:10","revision":"0","sha1sum":"caad16621a109b2065895a0b7d767a9561aa5e32","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"0","version":"2.60.23957.0"}],"id":{"product":"4f88f457c2f54e169ae4af95c2b1199f","version":"8cc616e5d3184452b20245ea5acad6b2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟及目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。<br>"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>설치 버튼을 클릭하여 설치 작업을 시작합니다.<br>"},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击安装按钮继续执行安装。<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ol>\n\t<li>The number of VMs is limited to 124 VMs with VMQ(Virtual Machine Queue) mode.</li>\n\t<li>The driver supports up to 200 vPorts in ConnectX-4 Lx and 254 vPorts in ConnectX-5 with SRIOV(Single Root I/O Virtualization).</li>\n</ol>\n","latest_fixes_x_late":"<ol>\n\t<li>This product correct an issue which caused memory corruption in case the OS provided continues memory across multiple pages that did not start with offset zero on aligned memory address.</li>\n\t<li>This product correct an issue that prevented the device from being updated with the new driver because the driver was already in the driver store.</li>\n\t<li>This product correct an issue which occasionally prevented the VF counters from being displayed correctly in perfmon.</li>\n\t<li>This product correct an issue which caused the driver to report zero link speeds supported when working with firmware older than 1x.18.0240.</li>\n\t<li>This product correct an issue which fixed a memory leak issue in error flow during driver initialization.</li>\n</ol>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a Windows Stop Error (BSOD) seen when running Mellanox NdStat Utility (mlx5cmd -ndstat) while ND connections was closing.</li>\n\t<li>This product corrects driver loading failures seen due to incorrect INF file.</li>\n\t<li>This product correct an issue where the vSwitch unavailable to assign on WS2012R2.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1563238","datemodified":"2021-01-27T02:33:46","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"0e8472ff1e455d081358ac99899461e0","name":"kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u2.x86_64.rpm","release":"2021-01-27T01:19:04","revision":"0","sha1sum":"2aa0ce4ee4a01e37fbf996376385d445ed9dd77a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"},{"bytes":"1313840","datemodified":"2021-01-27T02:35:58","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/rdma.conf","./etc/rdma/sriov-vfs","./etc/security","./etc/security/limits.d","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./lib/udev/mlnx_bf_udev","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/2e","./usr/lib/.build-id/2e/69333cf31a9973feca289064dbdeb1e2c28ad2","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/f5866863c897ffa9a2c50a12e11fe3b12fc643","./usr/lib/.build-id/7b","./usr/lib/.build-id/7b/f98da976ac382e331dfa0f2d1589f0ab3b3815","./usr/lib/.build-id/99","./usr/lib/.build-id/99/6a882fe8802e828e06b30425daf3cfbf840edb","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/4a6452865f4551843c28e68a25bf8e3d4af133","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/5d483b246a2a536cdc1e008af6f2d7fe8f9d41","./usr/lib/.build-id/c7","./usr/lib/.build-id/c7/873b30a996f52d289edad08eedc20e37debca3","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/45a1344b1461aee535e9923df0ea590b4d1592","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/e223b3f0c40249896f0fb0f9df22f26014f2c2","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/7441d854b6faaadee729fd69d61da232ca377e","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.32.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.11.32.0","./usr/lib64/libibverbs/libmlx5-rdmav25.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.16.32.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.32.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.2.2","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/libexec/rdma-set-sriov-vf","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/README.txt","./usr/share/doc/libvma/VMA_VERSION","./usr/share/doc/libvma/journal.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"8d778fe0de0c13f32bd812b8a20a794f","name":"mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u2.x86_64.rpm","release":"2021-01-27T01:19:04","revision":"0","sha1sum":"d183868a9701cff7fab5b75ab4d545cd772bdaa9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.2"}],"id":{"product":"ae6fc04bc51546468d12da8ed18bb5b3","version":"06c39365e33749a39deeb680a7f50dab"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.2&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version &nbsp;4.18.0-193.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u2.x86_64.rpm mlnx-ofa_kernel-5.2-OFED.5.2.1.0.4.1.rhel8u2.x86_64.rpm</strong><br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 2 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T08:09:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.1:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>The user can now set a packet pacing rate on the special queues that forward traffic from one physical port to the other.</li>\n\t\t<li>Connection Tracking (TC) offload on network interfaces that are in NIC mode, as opposed to SwitchDev mode. Note: This support is currently available for interfaces with physical functions only.</li>\n\t\t<li>Limiting SMP MADs on the wire using a Send window mechanism. This allows the user to keep track of the outstanding number of SMP MADs per-port, and allows for limiting this number to shape traffic when the pace of SMP MADs requires control.</li>\n\t\t<li>Direct Rule (DR) API support for sampling action to allow duplication and sampling of some ratio of the traffic. The API also allows to perform a set of different DR actions on the sampled traffic.</li>\n\t</ul>\n\t</li>\n\t<li>Enabled on-demand device memory sync to free cached memory.&nbsp;</li>\n\t<li>Simplified the sanity test that verified which systems must use python3 and not python2, so that when rebuilding the kernel packages using --add-kernel-support, the systems based on RHEL/CentOS 8 were detected.&nbsp;</li>\n\t<li>Added back rx_dct_connect counter that queries the number of received connection requests for the associated DCTs</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.1:</strong></p>\n\n<ul>\n\t<li>Extended mlx5 recovery-flow delay on VF driver when PCI interface went down</li>\n\t<li>ibv_get_device_list returned only accessible devices.</li>\n\t<li>&ldquo;rpmbuild&rdquo; (that includes basic support for building RPM packages) was not installed by the install script on SLES15 SPx systems when trying to rebuild packages.</li>\n\t<li>AF_XDP was not functional.</li>\n\t<li>neohost-backend and neohost-sdk packages were not properly removed by the uninstallation procedure and might have required manual removal before re-installing or upgrading MLNX_OFED driver.</li>\n\t<li>During MLNX_OFED installation, warning messages related to modules iw_cxgb3 and iw_nes might have appeared in the log.</li>\n\t<li>Command timeouts occurred when the Hypervisor disabled the VF&#39;s PCI interface. This fix reduces the device removal time to 2 seconds.</li>\n\t<li>MLNX_OFED/MLNX_EN installer will no longer automatically remove the spdk package when installing the driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and new features in HPE Mellanox RoCE driver&nbsp;version 5.2:</strong></p>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>CQE compression support for Rx multi-strides packets.</li>\n\t\t<li>Configuring QoS on a single QP or on a group of QPs.</li>\n\t\t<li>Encap/decap hardware offload of IPv4 traffic over MPLS-over-UDP. This can be used in networks with MPLS routers to achieve more efficient routing.</li>\n\t\t<li>Connection tracking rules on VFs to forward traffic from one VF to the other.</li>\n\t\t<li>Offloading sFlow sampling rules.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>A locking mechanism to enable parallel insertion of rules into the software steering using the mlx5dv_dr API. The parallel insertion improves the insertion rate and takes place when adding Rx and Tx rules via the FDB domain.</li>\n\t\t<li>Option to match mlx5dv_dr API on Geneve tunnel using a dynamic flex parser. The option header consists of class, type, length and data. The parser should be configured using devx command, after which a rule can be created to match on parser ID and data.</li>\n\t\t<li>Geneve tunneling offload, including matching on extension header.</li>\n\t\t<li>Parallel insertion and deletion of offloaded rules using multiple&nbsp;OVS threads.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>[Beta] Modify GTP-U TEID. This support requires flex parser&nbsp;configuration.</li>\n\t\t<li>[Beta] Improved performance of OVS Connection Tracking flows by&nbsp;enabling the merge of the multi-table flow matches and actions into one joint flow.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Dx Adapters and above:</strong></p>\n\n<p>Added support for the following features:</p>\n\n<ul>\n\t<li>Transmitted packet timestamping accuracy can be improved when using a timestamp generated at the port level instead of a timestamp generated upon CQE creation. Tx port time-stamping better reflects the actual time of a packet&#39;s transmission. This feature is disabled by default. The feature can be enabled or disabled using the following command. ethtool --set-priv-flags tx_port_ts on / off.</li>\n\t<li>Offloading tunnel rules when the source interface is VF (in addition to uplink) in the Hypervisor.</li>\n\t<li>Using Mirroring Offload with Connection Tracking.</li>\n\t<li>ASO flow meter using the mlx5dv_dr API, which allows for monitoring the packet rate for specific flows. When a packet hits a flow that is connected to a flow meter, the rate of packets through this meter is evaluated, and the packet is marked with a color copied into one of the C registers, according to the current rate compared to the reference rate.</li>\n\t<li>ASO first hit using the mlx5dv_dr API, which allows for tracking rule hits by packets. When a packet hits a rule with the ASO first hit action, a flag is set indicating this event, and the original value of the flag is copied to one of the C registers.</li>\n\t<li>mlx5dv_dr API support for matching on a new field &quot;gtpu_first_ext_dw_0&quot;. This field enables packet filtering based on the GTP-U first extension header (first dword only). To enable parsing of tunnel GTP-U extension header, run the following command. ./cloud_fw_reset.py FLEX_PARSER_PROFILE_ENABLE=3.</li>\n</ul>\n\n<p><strong>For&nbsp;ConnectX-6 Lx Adapters and above:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>IPsec full offload support for extended sequence number, replay protection window and lifetime packet limit.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>For&nbsp;All HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>New query GID API that allows for querying a single GID entry by its port and GID index, or querying for all GID tables of a specific device. This API works over ioctl instead of sysfs, which accelerates the querying process.</li>\n\t\t<li>Performing multi-host firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reload.</li>\n\t\t<li>[Alpha] Firmware live patching in the driver. Live patching updates the firmware without the need to perform firmware reset. However, it can only be applied in scenarios where the difference between the current and new firmware versions are minor, which is decided upon by the firmware itself.</li>\n\t\t<li>devlink tool for performing firmware reset in order to upgrade the device firmware. Firmware reset loads the new firmware in case it was burnt on the flash and was pending activation, and reloads the current firmware image from the flash in case no new firmware was pending. For further information, please refer to the the devlink man page.</li>\n\t\t<li>A resiliency mechanism for the driver to manually poll the command event queue (EQ) in case of a command timeout. In case the resiliency mechanism finds unhandled event queue entry (EQE) due to a lost interrupt, the driver will handle it, after which the command interface returns to a healthy state.</li>\n\t\t<li>Setting a sniffer private flag is deprecated and no longer required. In order to capture offloaded/RoCE traffic, tcpdump can now be run on the RDMA device.</li>\n\t\t<li>Added per-port reporters to devlink health to manage per-port health activities. Users can now access the devlink port reporters by specifying the port index in addition to the device devlink name through the devlink health commands API. This update was first introduced in iproute2 v5.8. As part of this feature, mlx5e Tx and Rx reporters are now redefined as devlink port reporters. For examples, please see devlink-health manpage</li>\n\t\t<li>Optimized memory consumption of memory registration in huge page systems. As an example, in a 2MB huge page system, 600 MB would be saved for 100 GB memory registration.</li>\n\t\t<li>mlx5dv API to modify the configured UDP source port for RoCE packets of a given RC/UC QP when QP is in RTS state.</li>\n\t\t<li>Accelerating Tx datapath by saving PCI bandwidth and CPU utilization. The savings are achieved by aggregating multiple packets into a single WQE. The feature is driven by xmit_more for certain traffic types, such as UDP.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.2:</strong></p>\n\n<ul>\n\t<li>Clearing min_rate on all SR-IOV legacy VFs after setting min_rate to at least one of the VFs did not disable QoS min_rate.</li>\n\t<li>An empty /usr/src/mlnx-ofa_kernel/default is now no longer created.</li>\n\t<li>An issue where installing packages through a repository failed after generation of metapackages using --add-kernel-support. The failure occurred due to excessive and incorrect Obsolete headers in those metapackages.Enabled installation of mlnx-ofa_kernel package to /bin/python3 instead of / usr/bin/python3 on RHEL 8.x systems.</li>\n\t<li>All IPoIB offload packets were wrongly counted as rx_csum_complete. These packets are now identified as rx_csum_unnecessary packets.</li>\n\t<li>mlx5dv_dr_rule_destroy segmentation fault could happen in rare cases with multiple rules on the same matcher with a different number of actions. This could happen after reusing an already deleted rule memory with less actions.</li>\n\t<li>An issue of moving to SwitchDev mode after configuring DSCP (Differentiated Service Code Point).</li>\n\t<li>Global traffic class configuration did not take effect on DC QPs (Dynamically Connected Queue Pairs).</li>\n\t<li>ib_send_bw traffic frequently dropped to zero when RDMA CM was used, because of incorrect&nbsp;min_rnr_timer setting on the responder side. The min_rnr_timer setting is now aligned with the setting in non-RDMA CM cases.</li>\n\t<li>Traffic did not pass over VFs with VST QinQ feature is enabled.</li>\n\t<li>When traffic was sent over Geneve VLAN with Tx VLAN offload enabled and TSO (TCP Segmentation Offload)&nbsp;or Tx csum enabled, traffic could be dropped and not sent to the wire.</li>\n\t<li>An issue that caused the firmware to restart upon installing mlnxofed-dpdk-upstream-libs package manually.</li>\n\t<li>Bad utility paths in rdma-core &quot;dracut&quot; hooks on SLES systems, which used to result in the following errors when running &quot;dracut&quot; with the &quot;--add rdma&quot; option. dracut-install:\n\t<ul>\n\t\t<li>ERROR: installing &lsquo;/usr/libexec/mlx4-setup.sh&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/mlx4-setup.sh dracut-install: ERROR: installing &lsquo;/usr/libexec/rdma-set-sriov-vf&rsquo; dracut: /usr/lib/dracut/dracut-install -D /var/tmp/dracut.UdCOSJ/ initramfs /usr/libexec/rdma-set-sriov-vf</li>\n\t</ul>\n\t</li>\n\t<li>Traffic class value was not updated in DCT when set via sysfs.</li>\n\t<li>A doorbell loss issue on AMD platforms with Secure Memory Encryption (SME).</li>\n\t<li>Registering memory using mlx5dv_devx_umem_reg while forking. Without this fix, applications which use fork() or similar syscalls while using a memory registered with umem_reg could hang due to incorrect physical page mapping. This fix requires setting the IBV_FORK_SAFE environment variable.</li>\n\t<li>When&nbsp;unbinding the device resulted in the following message being printed to the dmesg: &quot;failed to disable DC tracer&quot;</li>\n\t<li>Content of file /sys/class/net//statistics/ multicast might have been out of date and might have displayed values lower than the real values.</li>\n\t<li>ERSPAN (Encapsulated Remote SPAN) protocol was available only when turning off Tx checksum offload.</li>\n\t<li>A udev script issue which caused non-mellanox devices to be renamed.</li>\n\t<li>Missing representor statistics when using ifconfig.</li>\n\t<li>Fixed wrong value of skb mark of received packets on representors.</li>\n\t<li>An issue which caused second port representors to be named as first port representors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB Drives "},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEFNAおよびMB6000GEFNBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"16970132","datemodified":"2021-01-28T11:55:20","file_list":["/CP045656_BUILD_4.data","/CP045656.vmexe","/CP045656.vmexe64","/CP045656.vmfile","/CP045656_VMw.zip","/CP045656.xml","/payload.json","/CP045656_VMw.zip/index.xml","/CP045656_VMw.zip/vendor-index.xml","/CP045656_VMw.zip/metadata.zip","/CP045656_VMw.zip/vib20/CP045656/HPE_bootbank_CP045656_HPG6.4-7.0.0.15843807.vib","/CP045656_VMw.zip/metadata.zip/vendor-index.xml","/CP045656_VMw.zip/metadata.zip/vmware.xml","/CP045656_VMw.zip/metadata.zip/vibs/CP045656-4105641474618672107.xml","/CP045656_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045656_HPG6.4-7.0.0.15843807.xml"],"md5sum":"9cb0eb20875fcce46cc3456cebf174ea","name":"CP045656.zip","release":"2021-01-28T11:51:21","revision":"0","sha1sum":"3408a9c2e3809dc97c84271dfcf89f2f2d7bb463","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP045656","version":"HPG6.4-7.0.0.15843807"}]}],"id":{"product":"27c04cd9178a40abb16f9409a4957000","version":"cc56f8eb530242988bdb51624abb5cd8"},"installation":{"command":"CP039421.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:57:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD2"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD2"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n     </strong>None</p>"}],"files":[{"bytes":"2990320","datemodified":"2020-12-17T14:01:27","file_list":["cp045492.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEn0HPD2.REL"],"md5sum":"c9ad58483375dd9eed710180bfe725b4","name":"cp045492.exe","release":"2020-12-17T13:53:15","revision":"0","sha1sum":"e90488940f8e291a76ee8107ba8af80db4a641cd","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"d09d3bc174174ab69b229c1370a5ce48","version":"472c76d84358440e8dcf6f46511a4e03"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:29:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD2"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18211829","datemodified":"2021-01-28T15:40:36","file_list":["/CP045696_BUILD_4.data","/CP045696.vmexe","/CP045696.vmexe64","/CP045696.vmfile","/CP045696_VMw.zip","/CP045696.xml","/payload.json","/CP045696_VMw.zip/index.xml","/CP045696_VMw.zip/vendor-index.xml","/CP045696_VMw.zip/metadata.zip","/CP045696_VMw.zip/vib20/CP045696/HPE_bootbank_CP045696_HPD2.4-7.0.0.15843807.vib","/CP045696_VMw.zip/metadata.zip/vendor-index.xml","/CP045696_VMw.zip/metadata.zip/vmware.xml","/CP045696_VMw.zip/metadata.zip/vibs/CP045696--7824885895600222716.xml","/CP045696_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045696_HPD2.4-7.0.0.15843807.xml"],"md5sum":"ebe6a92a3bcdc182e4d8429ec1a366f0","name":"CP045696.zip","release":"2021-01-28T15:38:04","revision":"0","sha1sum":"39daead31107f967cf7e5b3620985a2bb2aa28ab","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045696","version":"HPD2.4-7.0.0.15843807"}]}],"id":{"product":"386eb9df6414454ca63bfe17b21ac760","version":"d47a5a14853d45daaae563592e9c5c58"},"installation":{"command":"CP043259.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:30:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1620000","datemodified":"2019-10-24T20:09:04","file_list":["bepnic.dll","bepnic.rtf","cp039928.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"796753d16dc2c99cf5f101385739f9fe","name":"cp039928.exe","release":"2019-10-24T19:55:07","revision":"0","sha1sum":"ed3fdcdb8062af2d74919908fab869c333b2efdd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"950aa10923d94fe39adbfe18fa1f4f69","version":"b84df531ebff46cd852c26f657f1d0b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18154747","datemodified":"2021-01-27T16:05:48","file_list":["/CP045644_BUILD_5.data","/CP045644.vmexe","/CP045644.vmexe64","/CP045644.vmfile","/CP045644_VMw.zip","/CP045644.xml","/payload.json","/CP045644_VMw.zip/index.xml","/CP045644_VMw.zip/vendor-index.xml","/CP045644_VMw.zip/metadata.zip","/CP045644_VMw.zip/vib20/CP045644/HPE_bootbank_CP045644_HPG2.5-7.0.0.15843807.vib","/CP045644_VMw.zip/metadata.zip/vendor-index.xml","/CP045644_VMw.zip/metadata.zip/vmware.xml","/CP045644_VMw.zip/metadata.zip/vibs/CP045644-5628697141372717721.xml","/CP045644_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045644_HPG2.5-7.0.0.15843807.xml"],"md5sum":"3bf5e6c8955bae50b593d2b2e63dc3cf","name":"CP045644.zip","release":"2021-01-27T16:03:05","revision":"0","sha1sum":"62b93cc19ccaf38f41540f723e87253b9804422e","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP045644","version":"HPG2.5-7.0.0.15843807"}]}],"id":{"product":"3fa689b1e0c54064af40f5128fac0e5b","version":"d1953cb3dddb46558bf5dd5cdccd4992"},"installation":{"command":"CP041453.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:45:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp045309.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.423"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3799376","datemodified":"2020-10-30T08:32:02","file_list":["cp045309.compsig","cp045309.zip","cp045310.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"a85e20cd8c27ff0f6b0b86cd28a90196","name":"cp045310.exe","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"db31136c08d465a42e3ab7f314db90e226e4a051","size":"3MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"1","version":"04.01.04.423"}],"id":{"product":"ffc5db5b28504df99cd08b4bf08ccc7d","version":"78c334e5f6094fde8245444c9d5ca7ab"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">HP USB Key Utility</a></strong>を使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Gen10サーバー向けServer Platform Services(SPS)ファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-12-11T03:52:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services Firmware provides mitigations for security vulnerability documented as CVE-2020-8755. This security vulnerability is documented in Intel Security Advisory INTEL-SA-00391. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD3"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB004000JWFVK and MB006000JWFVL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWFVKおよびMB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>      </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3022360","datemodified":"2020-12-17T06:50:45","file_list":["cp045520.xml","cpqsetup.exe","payload.json","setup.dll","TATCATdsHPD3.REL"],"md5sum":"310aae1cd7ab846d49c4777fa5ae62fd","name":"cp045520.exe","release":"2020-12-17T06:34:09","revision":"0","sha1sum":"84c7e4831190f3df8351cd481403a781efbd6626","size":"2MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"e0822b357e024225a58d203426c0d686","version":"fb12431d29f0473889e007503eb43659"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:39:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:40px\">None</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4864302","datemodified":"2020-12-13T13:54:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/CP045436.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/TTMRESD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045436.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045436.scexe"],"md5sum":"eff2505d177df07a0f406e81e91f8cca","name":"firmware-hdd-0f923833e9-HPD9-5.1.x86_64.rpm","release":"2020-12-13T13:43:04","revision":"0","sha1sum":"9d5b5468fa1b76a7de3e153be40a492da9e65913","size":"4MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"15b4903e0d104da184afbca47ab6234b","version":"09c9fe93422b439a99cf3bb12c1b7881"},"installation":{"command":"CP040306.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:16:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6956260","datemodified":"2020-10-29T10:09:37","file_list":["/CP046127.vmexe","/CP046127.vmfile","/CP046127.xml","/README.txt"],"md5sum":"e0f1c7d1002da23131543a450ffb50b6","name":"CP046127.zip","release":"2020-10-29T15:07:05","revision":"0","sha1sum":"d3df1d98e0ade5d2fd57feab78584fc4f11f4dba","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"40ac168079914e77b07d902faf8d27db","version":"adc0f7486c2e4410af71e13eceebc06a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi- HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - HPE ProLiant XL230a/XL250a Gen9（U13）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T17:48:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3185168","datemodified":"2020-12-11T11:17:03","file_list":["cp046320.xml","cpqsetup.exe","GPM1643ASAD4.rel","payload.json","setup.dll"],"md5sum":"e32e3f28b853f07e249bf4426c185540","name":"cp046320.exe","release":"2020-12-11T11:05:04","revision":"0","sha1sum":"25fa4ae9cc20fd9e7fd35e3fed417a4ad81c57b9","size":"3MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e5d8389759aa4832a8475a2ff763f16b","version":"c544a421a31c4531bb6b8af729eaa718"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T18:35:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPFand EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>       None</p>\n\n<p><strong>Known Issues:</strong><br />\n       None</p>"}],"files":[{"bytes":"2796672","datemodified":"2020-12-17T09:59:56","file_list":["cp045511.xml","cpqsetup.exe","GS865aG3.rel","payload.json","setup.dll"],"md5sum":"57529da15c64af6e22d5834c64190f88","name":"cp045511.exe","release":"2020-12-17T09:51:08","revision":"0","sha1sum":"4260a3b502b9113a590be88b237d1170271859e6","size":"2MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"249ebde928b24f7cb7ebdd3c20053940","version":"1b95fab71aaf4a879d0b4706c082a423"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:36:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4663456","datemodified":"2020-06-03T19:31:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/CP043983.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043983.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043983.scexe"],"md5sum":"35dd8ea30a343af5bb973d3e0dd7b5b2","name":"firmware-hdd-9a826ccd8a-HPK4-5.1.x86_64.rpm","release":"2020-06-03T19:21:05","revision":"0","sha1sum":"00a27e59cd181cfd2f7d74fee350ae1e29e4326d","size":"4MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"a35c5c84e8e149fe9fff61ed94a4a7ac","version":"fc959504d0a14bd78d2f9a092504c608"},"installation":{"command":"CP040088.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-08T14:50:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SLES12SP1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5960896","datemodified":"2020-10-29T15:23:32","file_list":["SignedImageInstaller64.dll","U13_2.80_10_16_2020.signed.flash","cp046125.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"8f7dd6306d4f5d03d1492761fcfcb2b9","name":"cp046125.exe","release":"2020-10-29T15:05:05","revision":"0","sha1sum":"11019aa9363a108b64a5101b64b8e9a411a6f5ec","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"536a9a6bb7f448b9be57c310c5a0b4ef","version":"ca777ad6a7614b7d80877b1e5d3e3e2d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230a/XL250a Gen9 (U13) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230a/XL250a Gen9 (U13)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"hpc","major":"6","minor":"1","name":"Microsoft Windows HPC Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-22T17:35:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"}],"sw_keys":[{"name":"U13","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"3388230","datemodified":"2021-03-21T03:33:01","file_list":["/cp044460.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/index.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/vendor-index.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/metadata.zip","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/vib20/sut/HPE_bootbank_sut_701.2.8.0.28-1OEM.701.0.0.16555998.vib","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/metadata.zip/vendor-index.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/metadata.zip/vmware.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/metadata.zip/vibs/sut-3737423172099332770.xml","/sutComponent_700.2.8.0.20-0-signed_component-17782108.zip/metadata.zip/bulletins/sutComponent_700.2.8.0.20-0.xml"],"md5sum":"c16f255ae724af84bb8707928b454aeb","name":"cp044460.zip","release":"2021-03-21T03:32:05","revision":"0","sha1sum":"ffd1982d367c3ebbfe4d56f2e052bf40546b9af2","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"type_of_change":"1","version":"2021.04.00","vib_list":[{"name":"sut","version":"701.2.8.0.28-1OEM.701.0.0.16555998"}]}],"id":{"product":"113bb71009854458ba860147296f93b4","version":"bc565d0b36d544ec995833ca638c5fdf"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li>\n\t<li>Enter the iLO credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li>\n</ol>\n\n<p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p>\n\n<p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmiS7agzZPZ\">SUM User Guide</a></p>\n\n<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the component bundle.</li>\n\t<li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.8.0 for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-01T10:30:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhyMagzZPY\">iSUT Release Notes</a> for information about the enhancements added&nbsp;in this release</p>\n","latest_fixes_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhxlqgzZPY\">iSUT Release Notes</a> for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhyMagzZPY\">iSUT Release Notes</a> for information about the enhancements added&nbsp;in this release</p>\n","curr_fixes_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhxlqgzZPY\">iSUT Release Notes</a> for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sutComponent:700.2.8.0.20-0","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-mezzanine Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2096464","datemodified":"2020-12-10T10:33:35","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp042241.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"9b4e0052797f66e31ddbbd0155f98890","name":"cp042241.exe","release":"2020-12-10T10:28:04","revision":"0","sha1sum":"caa8cdb2a8cfd98e7481f6e58803ee8e467f3b8f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"65745918a4694cd0a7c96fde04278213","version":"0ff7d2cb59c94744bf68b5821e0ae522"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2012R2/2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T11:00:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2012R2"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6090193","datemodified":"2020-11-05T05:02:15","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/CP046177.xml","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/U21_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u21-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046177.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046177.scexe"],"md5sum":"0021f4f0a52dc9d9b8c8c386ee3630f6","name":"firmware-system-u21-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-05T04:53:09","revision":"0","sha1sum":"a95d4bd486dc4e492c0d114f2a801d03626e3a4f","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"f68cbf39561d4281ab240a4897aa0415","version":"10de5bd087fa4a8aa1999e518b6e79bf"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL450 Gen9(U21)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T07:54:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"3645104","datemodified":"2020-12-17T13:15:23","file_list":["cp045498.xml","cpqsetup.exe","payload.json","setup.dll","STHBTND6.rel"],"md5sum":"3357338e83ef52591d9127de882899d4","name":"cp045498.exe","release":"2020-12-17T13:07:08","revision":"0","sha1sum":"39a96220e47cce8280efd1e69e20adf98abb0c92","size":"3MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"935cb1f792604e6aaead9dbf6e50463c","version":"fddd605d0f4b4b3e8eac3b776bf5e9a2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:31:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 7.0, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 7.0用lsi-mr3コントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"109485","datemodified":"2021-02-25T06:17:27","file_list":["/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip","/cp044980.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807.vib","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vibs/lsi-mr3-1377627193146561843.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807.xml"],"md5sum":"82834e1771a86e5ac7563f3ee0be2c77","name":"cp044980.zip","release":"2021-03-23T00:00:00","revision":"2","sha1sum":"bdea04824405306558d8cb07997d8fdb111810c1","size":"106KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba","20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"lsi-mr3","version":"7.716.03.00-1OEM.700.1.0.15843807"}]}],"id":{"product":"011fd838183d4fe38c4af2e3f27ece00","version":"b8b62b868b8847fdbe93e646676f8067"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hpe/swpackages and ./hpesum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li> CD /hpe/swpackages および ./hpesum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller (64-bit) Driver for vSphere 7.0 (Driver Component)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T08:40:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Initial Build for the MR416i-p, MR216i-a, MR416-a, MR216i-p drivers</strong></p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Initial&nbsp;release for the MR416i-p, MR216i-a, MR416-a, MR216i-p drivers</strong></p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-mr3:7.716.03.00-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-lsi-mr3:7.716.03.00-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HPE 6Gb SAS BL Switch. After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HPE 6Gb SAS BLスイッチのファームウェアイメージが含まれています。コンポーネントをダウンロードしてディレクトリにファームウェアイメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Windows&nbsp;(x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.3.6.0 (B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (C):</strong>&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"34248016","datemodified":"2018-11-27T03:29:38","file_list":["cp038273.xml","cp_data.xml","Entry.bsh","vsm_release_4.3.6.0.img"],"md5sum":"dd34c209e5f44e8294c17058ac55a93a","name":"cp038273.exe","release":"2018-11-27T09:28:04","revision":"0","sha1sum":"a28dcfb93408d6ad568751c732f5dc51abb55f76","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"3ed50c140ece462d9878c300a512c4f5","version":"2b418b1cf2454e5d9af13cfa6c71ef45"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><strong>To update firmware from&nbsp;Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.&nbsp;</li>\n\t<li>Double-click on the Smart Component.&nbsp;</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the </strong><a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u>&nbsp;</a><strong>&nbsp;(SPP) and follow these steps:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the firmware to be updated in the directory, \\SPP20xxxxx\\packages on the USB key.</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。 </li>\n\t<li>Smartコンポーネントをダブルクリックします。 </li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\">HP Service Pack for ProLiant</a><u>（SPP）を入手して、以下の手順を実行することをおすすめします。</u></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの\\SPP20xxxxx\\packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HPE 6Gb SAS BL Switch Firmware Smart Component for Windows (x86/x64)"},{"lang":"ja","x_late":"オンラインHPE 6 Gb SAS BLスイッチファームウェアSmart Component for Windows (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"10"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-27T09:14:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>\n\t<p style=\"margin-left:0in; margin-right:0in\">Improved integration with Smart Update Manager</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB2000GCWLT, MB3000GCWLU, and MB4000GCWLV Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n  Online HDD/SSD Flash Component for Windows (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3314816","datemodified":"2020-12-16T19:29:23","file_list":["cp045539.xml","cpqsetup.exe","HMKPB6G4.rel","payload.json","setup.dll"],"md5sum":"dc676806178ae47da4af4ce247f4b64e","name":"cp045539.exe","release":"2020-12-16T19:16:06","revision":"0","sha1sum":"1111559e21f61a59b940b56c11ea4fe0646b7538","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"451308857c63431786ef6960ba605a64","version":"f4fa59f7657a46b49ac8ec4f38076edc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:46:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027296","datemodified":"2020-12-02T21:32:19","file_list":["cp045177.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"2f387f26e76d9ffb512fa76889977a37","name":"cp045177.exe","release":"2020-12-02T21:09:13","revision":"0","sha1sum":"419e0223af8764d72dedd67739339b64fad3c77c","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"cad34a66b4fc4a06bf8a262ac99afab3","version":"9dc69c717b5840878cb37e21f6f3a865"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library ixtmsg.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16605706","datemodified":"2021-01-21T12:34:03","file_list":["/CP045969_BUILD_3.data","/CP045969.vmcfg","/CP045969.vmexe","/CP045969.vmexe64","/CP045969.vmfile","/CP045969_VMw.zip","/CP045969.xml","/payload.json","/CP045969_VMw.zip/index.xml","/CP045969_VMw.zip/vendor-index.xml","/CP045969_VMw.zip/metadata.zip","/CP045969_VMw.zip/vib20/CP045969/HPE_bootbank_CP045969_2.74.3-7.0.0.15525992.vib","/CP045969_VMw.zip/metadata.zip/vendor-index.xml","/CP045969_VMw.zip/metadata.zip/vmware.xml","/CP045969_VMw.zip/metadata.zip/vibs/CP045969--2105343978114660855.xml","/CP045969_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045969_2.74.3-7.0.0.15525992.xml"],"md5sum":"130de4826b35c1b35a7b7cd74e321929","name":"CP045969.zip","release":"2021-01-21T12:29:05","revision":"0","sha1sum":"c386518faa863e4eebf5c0d4075eb88700a35307","size":"15MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74","vib_list":[{"name":"CP045969","version":"2.74.3-7.0.0.15525992"}]}],"id":{"product":"8bcfdc333663490ba14bb0a7e2286062","version":"ff406fc4a93f4a84b8c37010f4fc22ac"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"HPE D6020 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-29T05:12:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v183133/D6020_P07232-008.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v191364/D6020_v2.74I.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYYV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYYV Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3682232","datemodified":"2020-12-16T16:58:24","file_list":["cp045555.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6SD2.rel"],"md5sum":"e7b67c0384ae0dc1a9ec8f1b31fd9b08","name":"cp045555.exe","release":"2020-12-16T16:50:04","revision":"0","sha1sum":"23c4b23734985d617517f1f5a007c8828a3fd0c1","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"eec8feb6cff84dc79bfbc2fc3ee22488","version":"91356dfd2b574e7aaccd3a59a0bfd081"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYYV Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:51:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6340338","datemodified":"2020-11-04T03:37:08","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/CP046146.xml","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/P89_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p89-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046146.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046146.scexe"],"md5sum":"386b87b8364f98ae013178324aa86c5e","name":"firmware-system-p89-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-04T03:27:05","revision":"0","sha1sum":"1556d71f50f95344d0b031ac574f618b2ddf5060","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"341b142bb61745f792508954cf786af9","version":"a580c721dedc4316afb93995088fe0d6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":" Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers"},{"lang":"ja","x_late":" オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen9/DL360 Gen9（P89）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T07:06:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137.  This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"P89","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.7.20.</p>\n"}],"files":[{"bytes":"352850","datemodified":"2019-10-24T14:38:10","file_list":["/cp039953.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/ixgben-1.7.20-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/doc/README.txt","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/doc/release_note_ixgben_1.7.20-1OEM.670.0.0.8169922.txt","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/vib20/ixgben/INT_bootbank_ixgben_1.7.20-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-ixgben-1.7.20.xml","/VMW-ESX-6.7.0-ixgben-1.7.20-14162871.zip/VMW-ESX-6.7.0-ixgben-1.7.20-offline_bundle-14162871.zip/metadata.zip/vibs/ixgben--3021017326292478617.xml"],"md5sum":"099e4c8aedd09d6edb0695b165f8146e","name":"cp039953.zip","release":"2019-10-24T19:38:03","revision":"0","sha1sum":"47d8eb5cc55dc929fa1631174e39de794bf23174","size":"344KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"ixgben","version":"1.7.20-1OEM.670.0.0.8169922"}]}],"id":{"product":"64cacd5223744f8db526479e2a86e773","version":"1c671ff8414c4d91818629790cf7a0f0"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.7.20-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.57.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.15.0</li>\n\t<li>qfle3, version 1.1.12.0</li>\n</ul>\n"}],"files":[{"bytes":"1381248","datemodified":"2021-01-13T14:25:21","file_list":["/cp045168.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.12.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.57.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.15.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3-711707153.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qcnic--1732253406.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/vibs/qfle3f-504550429.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.57.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.15.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.12.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.136-offline_bundle-17285089.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"9dffb534096d330445917a107fc87397","name":"cp045168.zip","release":"2021-01-13T14:24:06","revision":"0","sha1sum":"1a02e854667fb55bdeada48e66ee248e46a5d069","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344"],"type_of_change":"0","version":"2021.04.19","vib_list":[{"name":"qcnic","version":"1.0.57.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.15.0-1OEM.650.0.0.4598673"},{"name":"qfle3","version":"1.1.12.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e3347115cdc54c64abafd1793b901484","version":"b9631f0be28b4898a03bc75cbbbdb270"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses a VMkernel&nbsp;critical error&nbsp;(PSOD) seen during N-Port ID Virtualization&nbsp;(NPIV) VM power off.</p>\n\n<p>This product addresses a PSOD seen&nbsp;with FCoE.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qcnic:1.0.57.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.15.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.12.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1050369","datemodified":"2021-01-14T08:12:01","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"391cf277e9181d32d7c8c88c1fb70587","name":"be2iscsi-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"f4c69b955262ad19c50484d5be2e4cd9291156ae","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"978624","datemodified":"2021-01-14T07:58:20","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"2f7e5d427d02ae9abf84cc0848984d27","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"8039e9e645120611d5084ceeaa12336dd4d1180b","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"dd5b092a7dec4d3e9ecd257e4f87af47","version":"90e50c8ec51142778ad28c7f963aff19"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 1 and&nbsp;SUSE Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33595497","datemodified":"2021-01-27T21:59:04","file_list":["payload.json","U37_2.42_01_23_2021.signed.flash","U37_2.42_01_23_2021.xml"],"md5sum":"08d066eb3e09bcf73dcd51820682796f","name":"U37_2.42_01_23_2021.fwpkg","release":"2021-01-27T21:55:05","revision":"0","sha1sum":"28925bb9f7facf96dba5e7fe3e1257ef3fb31c80","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"644b370c36714c6490fce699ffce22e9","version":"d8b06a92707d4b72871ede7c1c64c3e9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T19:57:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727E0D6-F37B-447D-A9E4-5A7FB0B9DC8A","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5435_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-514180897A09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory 128 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5435_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-560580897A09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory 256 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5435_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-001080897A09","Version":"1.2.0.5435"},{"DeviceName":"Intel Optane DC Persistent Memory 512 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5435_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-551580897A09","Version":"1.2.0.5435"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This firmware package provides firmware for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のファームウェアを提供します。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"273477","datemodified":"2020-08-05T07:58:13","file_list":["dcpmm_01.02.00.5435.xml","fw_ekvb0_1.2.0.5435_rel.bin","payload.json"],"md5sum":"1b1ca5e30a98dcad10406c4f5cf2a3da","name":"dcpmm_01.02.00.5435.fwpkg","release":"2020-08-05T07:56:08","revision":"0","sha1sum":"989147867ed73db8b66059ab85fbff2cbf2d5a47","size":"267KB","target_guids":["805DD01C-EB5A-1E76-8089-514180897A09","805DD01C-EB5A-1E76-8089-560580897A09","805DD01C-EB5A-1E76-8089-001080897A09","805DD01C-EB5A-1E76-8089-551580897A09"],"type_of_change":"1","version":"01.02.00.5435"}],"id":{"product":"5618354fdcd14e80979abf0ff965a3f7","version":"0c2af031ff7542d9ba938890af81420f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the <strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>localhost OSの例：<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n\n<p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Intel Corporation"}],"name":[{"lang":"en","x_late":"Firmware package for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"},{"lang":"ja","x_late":"HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のファームウェアパッケージ"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-18T08:04:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains mainly performance improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains mainly performance improvements.</p>\n\n<p>This product now supports Red Hat Enterprise Linux 8, SUSE Linux Enterprise Server 12 and VMware ESXi 7.0.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK74H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK74H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK74H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3およびMZPLJ6T4HALA-000H3ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>EPK74H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"9363276","datemodified":"2021-01-23T12:50:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/CP046471.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/EPK74H3Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK74H3Q-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046471.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046471.scexe"],"md5sum":"2fcb0334f9681416049ec925db4aaa8a","name":"firmware-hdd-6628fce235-EPK74H3Q-1.1.x86_64.rpm","release":"2021-03-03T00:00:00","revision":"1","sha1sum":"b822ce99fc987f81ea909ce373ae7af58196e2cc","size":"8MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"1","version":"EPK74H3Q"}],"id":{"product":"77f2ff3d7ebf4999a5ec47887c09ecdf","version":"b724da62b8994d3dbf9ef3f6720001c5"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"},{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-16T08:11:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic FastLinQ Open-iSCSI driver for QLogic FastLinQ NICs running under Red Hat Enterprise Linux 8 Update 0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"584055","datemodified":"2019-10-07T17:58:01","file_list":["./sbin/iscsiadm.ql","./sbin/iscsid.ql","./sbin/iscsistart.ql","./usr/lib/.build-id","./usr/lib/.build-id/2e","./usr/lib/.build-id/2e/9366aca53704941bce26f858bf20d06a4da9e4","./usr/lib/.build-id/4e","./usr/lib/.build-id/4e/d23cc9d9b0f0a96b2da609f96d1b8772fb897e","./usr/lib/.build-id/93","./usr/lib/.build-id/93/e52a2820739a0534c2c6e7f00530a55fba3bfc","./usr/share/smartupdate/qlgc-open-iscsi/component.xml"],"md5sum":"76224f9fd28e833a56b551297eaad013","name":"qlgc-open-iscsi-2.0_873.113.rhel8u0-1.x86_64.rpm","release":"2019-10-07T17:57:02","revision":"0","sha1sum":"d8605e7a61f6f502d330cab229572b785ddbe134","size":"570KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17f154d7"],"type_of_change":"0","version":"2.0-873.113-1"}],"id":{"product":"a473be5520454dd493b4181c89c38278","version":"2c43cde3dbea42e4b20b37ee7784749a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package&nbsp;provided by&nbsp;this product is a&nbsp;pre-compiled kernel module driver&nbsp;built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp;HPE has tested and approved this&nbsp;pre-compiled kernel module RPM&nbsp;for use with the specified kernel.&nbsp;</p>\n\n<p>This pre-compiled RPM package&nbsp;may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Open-iSCSI Driver for Red Hat Enterprise Linux 8 Update 0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"qlgc-open-iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"332663","datemodified":"2021-01-14T07:59:42","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-193.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/f604ce6ba689784fd16c28956d99419bbca20d","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/3e8c1d1aab8e96a48688e3bb3ec6ec6e5b3769","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"d282c5d26409b0130dbe7aa194b56859","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel8u2.x86_64.rpm","release":"2021-01-14T07:45:04","revision":"0","sha1sum":"ebc7e3ce47119cb2d3498e006f593b4cc34e30df","size":"324KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"},{"bytes":"332571","datemodified":"2021-01-14T07:56:41","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/85","./usr/lib/.build-id/85/e71560552c72a92a8b798570ff996d89e31f7b","./usr/lib/.build-id/d2","./usr/lib/.build-id/d2/423e5bc79db491636e0b46f6d0095f0c0a1bb6","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"918ab36dba5801be59b738d85f15ed59","name":"kmod-bnxt_en-1.10.2-218.0.67.0.rhel8u3.x86_64.rpm","release":"2021-01-14T07:45:04","revision":"0","sha1sum":"f21c6db8df7eb16a99121a034e433b0699f8a03b","size":"324KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-218.0.67.0"}],"id":{"product":"12bc299e14c0483f95f66950ee1bea77","version":"e3a4f5c54acb4a5dac4f8ca4f09a183b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 Update 1</li>\n\t<li>This product now sets Maximum Transmission Unit(MTU) default value from firmware returned value</li>\n\t<li>This product now not support user establishing connections using RDMA communication manager(CM) when Priority-based Flow Control (PFC) configured VLAN ID is 0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which offload is not happening on bond(vf and virtio) interface after the fail over with VF as the active slave</li>\n\t<li>This product corrects an issue which driver loading failed on kdump kernel.</li>\n\t<li>This product corrects an issue which RoCE driver causes input&ndash;output memory management unit(IOMMU) warnings</li>\n\t<li>This product corrects an issue which RoCE Link Aggregation (RoCE LAG) when Maximum Transmission Unit(MTU) was changed.</li>\n\t<li>This product corrects an issue which Link up failed after resuming from hibernation</li>\n\t<li>This product corrects an issue which Virtual Function RoCE driver causes Virtual Machine to be rebooted</li>\n\t<li>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     HPG3<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None </p>\n\n<p><strong>Enhancements/New Features:  </strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2999680","datemodified":"2020-12-15T19:58:54","file_list":["4IYVHPG5.rel","cp045601.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"291b7016da8c21c41704e0aaf9b21d32","name":"cp045601.exe","release":"2020-12-15T19:36:05","revision":"0","sha1sum":"b364131cd0261ccc2f30b3b318fec21aa86fb117","size":"2MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"01713b1febed4cc9a463023eeb2cf6ee","version":"e80490f86e23458a80c86d1588c117fe"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:11:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15706545","datemodified":"2020-06-15T18:04:49","file_list":["/CP044497_BUILD_3.data","/CP044497.vmexe","/CP044497.vmexe64","/CP044497.vmfile","/CP044497_VMw.zip","/CP044497.xml","/payload.json","/CP044497_VMw.zip/index.xml","/CP044497_VMw.zip/vendor-index.xml","/CP044497_VMw.zip/metadata.zip","/CP044497_VMw.zip/vib20/CP044497/HPE_bootbank_CP044497_HPK4.3-7.0.0.15843807.vib","/CP044497_VMw.zip/metadata.zip/vendor-index.xml","/CP044497_VMw.zip/metadata.zip/vmware.xml","/CP044497_VMw.zip/metadata.zip/vibs/CP044497--6581979948749291332.xml","/CP044497_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044497_HPK4.3-7.0.0.15843807.xml"],"md5sum":"fd6c96eb5c861d2e0361e447d7edda7c","name":"CP044497.zip","release":"2020-06-15T18:02:04","revision":"0","sha1sum":"6572c2c00f576d54c310f8e49ba89d3573578455","size":"14MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP044497","version":"HPK4.3-7.0.0.15843807"}]}],"id":{"product":"151b3249eb8946acb43e16f663033dfa","version":"2967067fa0064d0381dd7464c1e8ea02"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-04T22:32:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"389232","datemodified":"2021-01-14T06:18:18","file_list":["/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip","/cp045075.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vibs/bnxtnet-2270757399935237568.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/vibs/bnxtroce--4512647262758159893.xml","/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807_17359297.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_218.0.243.0-1OEM.700.1.0.15843807.xml"],"md5sum":"0c3fbf91869dc97b4f525ef2be2e19bd","name":"cp045075.zip","release":"2021-01-14T06:17:05","revision":"0","sha1sum":"db314b401812e94ac0ad236d32212247e3ccd4e8","size":"380KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtnet","version":"218.0.38.0-1OEM.700.1.0.15843807"},{"name":"bnxtroce","version":"218.0.16.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"11a6992c4ec7430e9b4f2b44f5d06fe1","version":"9fd6d7637c6d4917a99111f0453038b8"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-bnxt-Net-RoCE:218.0.243.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4446077","datemodified":"2021-01-28T10:40:08","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/qlgc-qla2xxx","./lib/modules/4.12.14-195-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.12.14-195-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"817de735966f6022f5dcbc4f7612fbab","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-28T10:29:05","revision":"0","sha1sum":"ba25b59372e161220dc79d7f475830401ee67708","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"2ef4b1fccb0b4e4aa4c8281327ada522","version":"5094c3687a294a379cbdd89ef6fae593"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 1 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Driver for:</p>\n\n<p>SuSE Linux Enterprise Server 15 Service Pack&nbsp;1 version 10.01.00.64.15.1-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7203150","datemodified":"2021-01-21T22:05:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/CP045374.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/GP1725b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045374.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045374.scexe"],"md5sum":"6be4a1731366168c06a465b1aedbe2d8","name":"firmware-hdd-cea219e4b1-HPK3-1.1.x86_64.rpm","release":"2021-01-21T21:54:05","revision":"0","sha1sum":"bebfbeace0209b794acd11b0ec9198716418b0cb","size":"6MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"9548ad0612e149baa76eccbb5ce95cee","version":"cb3cf49c131c43dbbd880aa0106af292"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:25:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3646808","datemodified":"2020-12-16T19:23:37","file_list":["cp045540.xml","cpqsetup.exe","HAKPNFG6.rel","payload.json","setup.dll"],"md5sum":"8f2658b0c3ae8d73f10a8393ff467469","name":"cp045540.exe","release":"2020-12-16T19:08:04","revision":"0","sha1sum":"cd5ce2d2054d9e7344162a0ed1d1909a18bba351","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"c3a161d21e2947f3af496f6cde08c95f","version":"e9dd3ae6827c4dd9b2ee860fabf647e4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:46:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.16.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.16"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14015895","datemodified":"2021-01-29T04:25:10","file_list":["/CP043320_BUILD_61.data","/CP043320.vmexe","/CP043320.vmexe64","/CP043320.vmfile","/CP043320_VMw.zip","/CP043320.xml","/payload.json","/CP043320_VMw.zip/index.xml","/CP043320_VMw.zip/vendor-index.xml","/CP043320_VMw.zip/metadata.zip","/CP043320_VMw.zip/vib20/CP043320/HPE_bootbank_CP043320_1.16.61-7.0.0.15843807.vib","/CP043320_VMw.zip/metadata.zip/vendor-index.xml","/CP043320_VMw.zip/metadata.zip/vmware.xml","/CP043320_VMw.zip/metadata.zip/vibs/CP043320--3476641737704676686.xml","/CP043320_VMw.zip/metadata.zip/bulletins/Smart-Component-CP043320_1.16.61-7.0.0.15843807.xml"],"md5sum":"9657197231f3be8189a87ecf1c218c82","name":"CP043320.zip","release":"2021-01-29T04:06:04","revision":"0","sha1sum":"efa8971cf72954fb8c196d0e01076a96d0c46b70","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.16","vib_list":[{"name":"CP043320","version":"1.16.61-7.0.0.15843807"}]}],"id":{"product":"6c850a8782474532b42a51c8d341beac","version":"b323183f5407417ea4d0c6075671750e"},"installation":{"command":"CP043320.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HP Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM2 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"00000000-0000-0000-0000-000039363735","type":"pic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-04-02T09:45:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial release</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWFVC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>     </strong>  None</p>\n\n<p><strong>Known Issues:<br />\n       </strong>None</p>"}],"files":[{"bytes":"3026528","datemodified":"2020-12-17T13:43:19","file_list":["cp045494.xml","cpqsetup.exe","payload.json","setup.dll","T14SEhD3.REL"],"md5sum":"b855756a9f9f8808c13ca2f924353b39","name":"cp045494.exe","release":"2020-12-17T13:33:08","revision":"0","sha1sum":"9723f585740f3da984682e654fe77a71f2b14f59","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"55c20afa55214e04bc6d7e8985b8d0b6","version":"840b6903ae464c1bb89d3c61967cb719"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>RunÂ <em>launch_sum.bat</em> scriptÂ which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:29:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n     </strong>Online HDD/SSD Flash Component for Windows (x64) - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <strong> </strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3309448","datemodified":"2020-12-11T19:08:52","file_list":["cp045587.xml","cpqsetup.exe","payload.json","PLTGIID7.rel","setup.dll"],"md5sum":"551f0618d520d2675cb80f2f58ed61d4","name":"cp045587.exe","release":"2020-12-11T19:00:05","revision":"0","sha1sum":"e164ccfe901c9a0b1897abf976dfcb4698e611f2","size":"3MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"a5c4c8dc7b4a47d3abf311a168b0a29d","version":"08ff3a3ba3fd4dc5900fdc7a89393788"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:05:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5927096","datemodified":"2021-02-08T01:35:30","file_list":["P85_2.80_10_16_2020.signed.flash","SignedImageInstaller64.dll","cp046867.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"38bfc4a690f943da53417fcd8cdb3e96","name":"cp046867.exe","release":"2021-02-08T01:18:04","revision":"0","sha1sum":"7e020b11f451d06bb9a4753f9478dc3123c46da0","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"c740e1c15c784d9bb5ce0ea0e215f139","version":"276224996c4d4c65b0fd07dca2feb64b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen9 (P85)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-08T01:11:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 2.80_10-16-2020(B) contains updates to the firmware packaging and is functionally equivalent to ver. 2.80_10-16-2020. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 2.80_10-16-2020.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"}],"files":[{"bytes":"342007","datemodified":"2021-01-14T06:17:23","file_list":["/cp045073.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtnet--817500090.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtroce-2119692319.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtnet-218.0.38.0.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtroce-218.0.16.0.xml"],"md5sum":"888b963a3d1cdf1138f8392f166850b9","name":"cp045073.zip","release":"2021-01-14T06:16:06","revision":"0","sha1sum":"263568c9eca3a586b59481fe3c8a5a0716ee119a","size":"333KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"bnxtnet","version":"218.0.38.0-1OEM.650.0.0.4598673"},{"name":"bnxtroce","version":"218.0.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e382d013e99549e7a97161015561d31e","version":"6d7c2749736b46a2a8d83bec0de0b73d"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where RDMA Ethernet Controller error description on ESXi Host.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 - SAS Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 - SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; Apollo 2000 System</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.00(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15&nbsp; OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5181315","datemodified":"2018-09-26T20:08:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/CP034964.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/firmware-Release-1.00-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-1.00-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP034964.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP034964.scexe"],"md5sum":"41bd61a9d110293bbdf239892e01d7cf","name":"firmware-smartarray-3bf7ece88e-1.00-3.1.x86_64.rpm","release":"2018-09-27T00:55:08","revision":"0","sha1sum":"a65eadd368be57b08213fdcbe0a1b664b62c71eb","size":"4MB","target_guids":[],"type_of_change":"1","version":"1.00"}],"id":{"product":"5db40f307a93428cb2929e6801c9f6ed","version":"fc50dd7d9ed04af4aaf03b52e08f2ffd"},"installation":{"command":"CP034964.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP034964.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-3bf7ece88e-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP034964.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-3bf7ece88e-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-3bf7ece88e-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE Apollo 2000 System - SAS Expander"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 2000 System - SASエキスパンダー"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-03-15T06:36:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager.</li>\n</ul>\n\n<p style=\"margin-left: 40px;\">Note: Upgrading to version 1.00(B) is not necessary if the Apollo 2000 SAS Expander was previously updated to version 1.00.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15&nbsp; OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"}],"sw_keys":[{"name":"HP Apollo r2800","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-874253-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817749-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-817753-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28836171","datemodified":"2021-02-03T06:49:04","file_list":["/CP045194.vmexe64","/CP045194.vmfile","/CP045194_VMw.zip","/CP045194.xml","/payload.json","/README.txt","/CP045194_VMw.zip/index.xml","/CP045194_VMw.zip/vendor-index.xml","/CP045194_VMw.zip/metadata.zip","/CP045194_VMw.zip/vib20/CP045194/HPE_bootbank_CP045194_1.0.0-7.0.0.15525992.vib","/CP045194_VMw.zip/metadata.zip/vendor-index.xml","/CP045194_VMw.zip/metadata.zip/vmware.xml","/CP045194_VMw.zip/metadata.zip/vibs/CP045194--2079234640780550429.xml","/CP045194_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045194_1.0.0-7.0.0.15525992.xml"],"md5sum":"f13fe9ba8c3c5a28febc2d0d48d72ef4","name":"CP045194.zip","release":"2021-02-03T06:54:04","revision":"0","sha1sum":"68734b3f229bc21af94a4e65d2ae20aec6ecae5d","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045194","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"4a88cfeb4a984c96a13ab1090bcaab71","version":"94c469cdb1be47998e2b35d3fd753df2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox Ethernet only adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-12T07:11:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HP Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HP Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.27.4000:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.27.2008:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction:\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The sent packet hung while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>The completions (CQ)completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.&nbsp;</li>\n\t<li>The fragmented IP packets were dropped.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.29.1016:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.29.1016:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><strong>New features and changes in version 14.29.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>cq_overrun counter: This counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.28.1016:</strong></p>\n\n<p style=\"margin-left:40px\">Added support for following features:</p>\n\n<ul>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>ixes submitted in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) &nbsp;NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused&nbsp;packets to drop due to header size issues and/or failing checks. The issue was caused due to a Linux issue that caused&nbsp;VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was&nbsp;enabled by NVCONFIG and a large number of VFs were configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>&nbsp;An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>&nbsp;An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>The&nbsp;eth_wqe_too_small counter to count&nbsp;ODP page used to fail.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>An issue that resulted in low performance after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to dead IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"}],"files":[{"bytes":"3564592","datemodified":"2019-10-24T14:37:29","file_list":["/cp039935.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"ca98f9436ce75271d57af62b5c502ee3","name":"cp039935.zip","release":"2019-10-24T19:37:06","revision":"0","sha1sum":"569d731dd3673ac54bb50ac20a47eccdc7f5a7bc","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7cdc9cd1c70149848e6e26c6af8613a5","version":"51005bcbd2fb480a9f049a581ad94152"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"837912","datemodified":"2021-02-01T06:57:40","file_list":["cp046080.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"a8bf21047fa553ccdcc5c939de4b1b48","name":"cp046080.exe","release":"2021-02-01T06:41:04","revision":"0","sha1sum":"1a61822d2db6fe53e74ab64ce32c749ca750f590","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"7a409aa1e5444a57b8b10f884c98ae5f","version":"e3e9525cbf9e4cd9a3568ee12f365d20"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPS1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPS1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPS1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPS1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVMe drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMeドライブモデルのファームウェアを提供します。MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPS1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"6853551","datemodified":"2020-12-12T22:15:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/CP045368.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/HPS1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPS1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045368.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045368.scexe"],"md5sum":"6b3450ecdc43381b9d35381b7e66dac9","name":"firmware-hdd-8e8ddc5265-HPS1-5.1.x86_64.rpm","release":"2020-12-12T22:04:05","revision":"0","sha1sum":"9692b2974808922b368a18c12c9d73db16137115","size":"6MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPS1"}],"id":{"product":"0d61f1ea72cf4d4991d4093a05f8808a","version":"c34aa76301cc44ed932bb02ef65f5f7f"},"installation":{"command":"CP040131.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:16:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR&nbsp;and VK001600GWCNT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4662768","datemodified":"2020-12-13T15:16:51","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/4IDVHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/CP045458.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045458.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045458.scexe"],"md5sum":"99a9393e7b44131f28230d136bac0fa6","name":"firmware-hdd-6e3845def5-HPG1-5.1.x86_64.rpm","release":"2020-12-13T15:05:08","revision":"0","sha1sum":"ff6793666ca3b7f90de1078da0f847d309033aed","size":"4MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"bc34fe37ff6f4e0b9f7866222b805e05","version":"d46e4c1d21f54177a615a7aa45fe9846"},"installation":{"command":"CP040345.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:18:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-r Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1052"},{"DeviceName":"HPE NS204i-t Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_NS204i_Gen10P_1052.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1052"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The x64 Smart Component provides firmware for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r\n\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\nOnline ROM Flash Component for ESXi&nbsp;- HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1052<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.0.14.1047<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Support for HPE Gen10+ Boot Controllers: NS204i-p, NS204i-d, NS204i-t, NS204i-r.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2455702","datemodified":"2021-02-08T11:07:19","file_list":["/CP044515_BUILD_18.data","/CP044515.vmexe","/CP044515.vmexe64","/CP044515.vmfile","/CP044515_VMw.zip","/CP044515.xml","/payload.json","/CP044515_VMw.zip/index.xml","/CP044515_VMw.zip/vendor-index.xml","/CP044515_VMw.zip/metadata.zip","/CP044515_VMw.zip/vib20/CP044515/HPE_bootbank_CP044515_1.0.14.1052.18-7.0.0.15843807.vib","/CP044515_VMw.zip/metadata.zip/vendor-index.xml","/CP044515_VMw.zip/metadata.zip/vmware.xml","/CP044515_VMw.zip/metadata.zip/vibs/CP044515--8177777706529310120.xml","/CP044515_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044515_1.0.14.1052.18-7.0.0.15843807.xml"],"md5sum":"735af71e6213decb742fe2d8b91191c3","name":"CP044515.zip","release":"2021-02-08T11:05:04","revision":"0","sha1sum":"b688e02cdfe176e6215fb838eaab2bbd7d4ad08c","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310"],"type_of_change":"1","version":"1.0.14.1052","vib_list":[{"name":"CP044515","version":"1.0.14.1052.18-7.0.0.15843807"}]}],"id":{"product":"f0c6d80ec7ba4100b11a93d13a983f16","version":"9618ed9dc6844f03970889cad066d536"},"installation":{"command":"CP044515.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Flash for ESXi - HPE NS204i-p, NS204i-d, NS204i-t, NS204i-r Gen10+ Boot Controller"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"0310","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-224115900310","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030f","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030e","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-08T08:13:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Firmware Smart Component release for HPE Gen10+ Boot Controller</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>&nbsp;</p>\n\n<ul>\n\t<li>Added support for Gen10+ Snap4 models: NS204i-d, NS204i-t, NS204i-r</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"03101590","sw_key_expectedpath":"firmware:sd:"},{"name":"030E1590","sw_key_expectedpath":"firmware:sd:"},{"name":"030F1590","sw_key_expectedpath":"firmware:sd:"},{"name":"02F61590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16812733","datemodified":"2020-11-03T04:50:30","file_list":["payload.json","U44_2.20_10_27_2020.signed.flash","U44_2.20_10_27_2020.xml"],"md5sum":"21888ee76e63cc959a089b39c6687035","name":"U44_2.20_10_27_2020.fwpkg","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"da3b5356e74b71e905605ee4c43e2c47370cb3f8","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"f2f901fd357f4c6692fae66dcbbb15ed","version":"725a4aed694a459998940a94170f2ff2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10(U44)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2099856","datemodified":"2021-01-22T06:29:36","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp042530.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"eb8b39998687963afc857370de3624b9","name":"cp042530.exe","release":"2021-01-22T06:25:06","revision":"0","sha1sum":"be86c122cf94e78e74f30a2a11bd3e17602d4f6b","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"bbe1b570fa0b489d9f3ea7ce12b8f909","version":"8359557e7e404ddfb9de8efe90f3027b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p> </p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:44:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Added support for following:</p>\n\n<p>Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Added support for following:</p>\n\n<p>Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P230i、P430、P431、 P731m、P830i 和 P830"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P230i、P430、P431、P731m、P830i 及 P830"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P230i, P430, P431, P731m, P830i, P830"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP230i, P430, P431, P731m, P830i, およびP830のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array Smart Array P230i,&nbsp;P430, P431, P731m, P830i, and P830</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;5.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;4.54(A)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.10<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4522856","datemodified":"2019-08-08T19:34:34","file_list":["cp039412.xml","cpqsetup.exe","firmware_signed.bin.fw","setup.dll"],"md5sum":"132789cbb848580920360dac59e1f3c5","name":"cp039412.exe","release":"2019-08-08T19:17:06","revision":"0","sha1sum":"cd610b589b2428ac72216bcbe2d1c3df054ea109","size":"4MB","target_guids":[],"type_of_change":"0","version":"5.02"}],"id":{"product":"9aa489b872204af29fd466db29be29fa","version":"7f9840894d3d417c9e7db6d3d61dd138"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the <a href=\"http://www.hpe.com/info/spp\">HPE </a></strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><a href=\"http://www.hp.com/go/spp\"> </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには <a href=\"http://www.hpe.com/info/spp\">HPE </a></strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><a href=\"http://www.hp.com/go/spp\"> </a><strong>:</strong></strong></p>\n\n<p> </p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします</li>\n\t<li>ISOのルートにあるStart.htmlを特定します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array P230i, P430, P431, P731m, P830i, and P830"},{"lang":"cn","x_late":"Windows (x64)版在线ROM刷新组件 - 智能阵列P230i、P430、P431、P731m、P830i和P830"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 - Smart Array P230i、P430、P431、P731m、P830i 與 P830"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P230i, P430, P431, P731m, P830i 및 P830"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - SmartアレイP230i、P430、P431、P731m、P830i および P830"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-05-09T06:05:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>The firmware updates could fail while SmartCache is enabled due to active I/O in the Smart Cache.</li>\n\t<li>The serial output of the expander could fail to be populated in the controller logs due to the buffer not being handled appropriately by the controller</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"}],"sw_keys":[{"name":"1928103c","sw_key_expectedpath":"firmware"},{"name":"1923103c","sw_key_expectedpath":"firmware"},{"name":"1922103c","sw_key_expectedpath":"firmware"},{"name":"1924103c","sw_key_expectedpath":"firmware"},{"name":"1921103c","sw_key_expectedpath":"firmware"},{"name":"1926103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6173865","datemodified":"2020-12-13T12:53:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/CP045424.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/HLEBHssseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045424.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045424.scexe"],"md5sum":"c1a455bb66f3242afdb2d2c627a4183f","name":"firmware-hdd-cfd7436fcc-HPD2-4.1.x86_64.rpm","release":"2020-12-13T12:42:08","revision":"0","sha1sum":"e501b16b60c9ce0d681a7b8ffa1e5bdf5d24e60f","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"6cc89934ad1740b582b096e05315f04a","version":"301df59b8e4e463d84bf5bd4de2c9a91"},"installation":{"command":"CP041518.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5969160","datemodified":"2020-11-04T11:07:11","file_list":["SignedImageInstaller64.dll","U20_2.80_10_16_2020.signed.flash","cp046153.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"e05d4bd6c2e413a6c7c1b090fe505049","name":"cp046153.exe","release":"2020-11-04T10:50:07","revision":"0","sha1sum":"8383dedc12d7b75dc7984b8d78b4839b931b1a83","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"749b691cbdee45b1901a105f2f1d7a48","version":"5324c45a18f548328abc9f74279c0012"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen9/DL180 Gen9 (U20) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T09:19:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"}],"sw_keys":[{"name":"U20","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1639371","datemodified":"2021-01-22T05:02:21","file_list":["./opt/broadcom/sles15sp1/i386/lib/libbrcmdfc.so","./opt/broadcom/sles15sp1/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles15sp1/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp1/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles15sp1/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles15sp1/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles15sp1/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles15sp1/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp1/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles15sp1/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"6078e6c12695b15c2a1f383c27a9303f","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles15sp1.x86_64.rpm","release":"2021-01-22T04:57:28","revision":"0","sha1sum":"1747a78262f43e20a765b3e5e22a4647a7abb269","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"},{"bytes":"1639368","datemodified":"2021-01-22T05:06:07","file_list":["./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"45a28f1431755099bb4348f285ade8ff","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles15sp2.x86_64.rpm","release":"2021-01-22T04:57:28","revision":"0","sha1sum":"92417847b3347e1c500929f2a7789915d0e7c65e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"c901792d2373446f89ecbbbaab9a8f09","version":"dd56668620fb4ffb99be094656d7c8c2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:52:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1264.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD8"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5709033","datemodified":"2020-12-13T08:35:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/CP046267.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/SKESTED8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046267.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046267.scexe"],"md5sum":"a9d2cd63c5a94a8c0ffd3ae60f57f90f","name":"firmware-hdd-a05f29cef3-HPD8-2.1.x86_64.rpm","release":"2020-12-13T08:24:09","revision":"0","sha1sum":"c0bf8a7a5173b0805f90afe9efa523117e6b19fa","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"365d207e25654d61b3829f731965d204","version":"bf7553f20c2c45a68e3bb7d6aad8fb04"},"installation":{"command":"CP040712.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:  <em>rpm -ivh <rpm_filename>. </em> This extracts the contents of the rpm to the '/usr/lib/x86_64-linux-gnu' location.</li>\n\t<li>The CP<nnnnnn>.scexe script is located in the 'scexe-compat' folder. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the first step above.  </li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP<nnnnnn>.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location (OR)</li>\n\t\t<li><em>./setup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e <rpm_package_name></em>, which is the rpm filename without the '.rpm' extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio <rpm_filename>.rpm | cpio -id. </em> This extracts the contents of the rpm to 'usr' folder in the current directory.</li>\n\t<li>Navigate to the 'usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*' location and run <em>./setup</em> to update the firmware. The actual name of the 'firmware-hdd-<xxxxxxxxxx>-*' folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.  It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a> on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run <em>launch_sum.sh</em> script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-12T17:13:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component provides 64-bit Microsoft Windows Server 2012, 2012 R2, 2016, and 2019 editions support for the HPE Smart Array SAS/SATA Controllers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"641160","datemodified":"2019-08-08T18:29:23","file_list":["cp037982.xml","cpqsetup.exe","generic.dll","hpcisss3.cat","HpCISSs3.inf","HpCISSs3.sys","install.xml"],"md5sum":"e88061a72ff394691b660c5623939c09","name":"cp037982.exe","release":"2019-08-08T18:28:02","revision":"0","sha1sum":"254caef290fcbee936a85a53a45a9579c390dd1b","size":"626KB","target_guids":[],"type_of_change":"1","version":"106.26.0.64"}],"id":{"product":"32cb58a13b764af9aba40956dbeca3b6","version":"90b6d3b309174d6f86065034ff4ebdab"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。下載的檔案為自我解壓縮的可執行檔，其檔名包含智慧型元件編號。 <br><p>從該磁碟和目錄，執行下載的檔案。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다. 다운로드한 파일은 스마트 구성 요소 번호에 따라 파일 이름이 지정된 자동 압축 풀기 실행 파일입니다. <br><p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다."},{"lang":"cn","x_late":"将智能组件下载到硬盘目录中，然后转至该目录。下载的文件是一个自解压可执行文件，其文件名基于 Smart Component 编号命名。 <br><p>在该硬盘目录中，执行下载的文件。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。 <br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array HPCISSS3 Controller Driver for 64-bit Microsoft Windows Server 2012/2012 R2/2016/2019 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1920","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1925","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows 8 (64-bit)","platform":"nt-x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-26T06:51:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>System could potentially&nbsp;display a BSOD while executing a hot replace due to a memory aligment problem</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"R02","value":"HP X1600 Network Storage System"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A29","value":"HP ProLiant DL585 Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpcisss3.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB6000JVYZD and MB4000JVYZC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：MB6000JVYZDおよびMB4000JVYZCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5538288","datemodified":"2020-12-13T14:27:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/CP045445.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/SMBPESD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045445.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045445.scexe"],"md5sum":"be238f01409c4f334385aa364b829a57","name":"firmware-hdd-e800e8d3b9-HPD4-5.1.x86_64.rpm","release":"2020-12-13T14:15:05","revision":"0","sha1sum":"878394d8b695fdbe690a0fcc2e709dd993c20540","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f433cea5bd0849d286e6c1b1e45a60d4","version":"cd4be0be3e2e449db1f2aeabc8dd6f4f"},"installation":{"command":"CP040325.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB6000JVYZD and MB4000JVYZC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.57.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.14.2</li>\n\t<li>qfle3, version 1.1.12.0</li>\n</ul>\n"}],"files":[{"bytes":"1383589","datemodified":"2021-01-27T16:00:13","file_list":["/cp045167.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.12.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.14.2-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.57.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3--2209508695182818550.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3f-6322780130870546795.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/vibs/qcnic-5446603038068585093.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922-offline_bundle-17389891.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.135.2-1OEM.670.0.0.8169922.xml"],"md5sum":"b0e6ca1293acb982b3b4a279821d8d54","name":"cp045167.zip","release":"2021-01-27T15:58:05","revision":"0","sha1sum":"8bf0fe4acda5411bdbd91f6e4fdcd311a5392626","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe"],"type_of_change":"0","version":"2021.04.19","vib_list":[{"name":"qfle3","version":"1.1.12.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3f","version":"1.1.14.2-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.57.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"86ed65a9ad3d4de69d4874b14dbe2a9a","version":"b90333ff56d04a63a5c221754fa46c9f"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses a VMkernel&nbsp;critical error&nbsp;(PSOD) seen during N-Port ID Virtualization&nbsp;(NPIV) VM power off.</p>\n\n<p>This product addresses a PSOD seen&nbsp;with FCoE.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware vShere 6.7 U3.<br />\nThis product has improved handling of complex flooding and race condition issues.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qfle3:1.1.12.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.14.2-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.57.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2012 R2を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1589824","datemodified":"2020-06-12T10:46:39","file_list":["bepnic.dll","bepnic.rtf","cp044540.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd64.cat","ocnd64.inf","ocnd64.sys"],"md5sum":"0d94a80e865a3ae659c8dcb2dd273d49","name":"cp044540.exe","release":"2020-06-12T10:33:05","revision":"0","sha1sum":"9f5c08a08ca75a06c423d78f294dd553e349399d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec173970a5"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"ab8b689939f94b78976081b76f12fa41","version":"b277a830033240b4a5a985cfb14cfe76"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ocnd64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3109792","datemodified":"2021-01-21T07:03:30","file_list":["cp044812.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"bccf7e2f5a9f9d8388f621f127ff16ab","name":"cp044812.exe","release":"2021-01-21T06:53:06","revision":"0","sha1sum":"2073043c9a69d1e068b2321ef85a31b4f49a1c02","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"0","version":"5.2.4.0"}],"id":{"product":"dcd60b858b6c4ac298dc49b61299aeb5","version":"45bde9430773406fb2b796799e73862c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"8.37.37.0","description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product corrects the abnormal disconnection of iLO web page while performing under Shared Networking on Flexible-LOM.</li>\n\t<li>This product addresses an issue where the HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 and &nbsp;HPE Ethernet 10/25Gb 2-port 621SFP28 adapter UMCE (Uncorrectable Machine Check Exception) was followed by Unrecoverable I/O error, Uncorrectable PCI express error on Server and one of the ports suddenly no longer can send or receive traffic.</li>\n\t<li>This product addresses an issue where driver doesn&rsquo;t load upon booting up by correct memory relocation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLBBFWUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"tw","x_late":"此元件可更新 HPE Gen9 伺服器上的進階功率限定微控制器韌體。"},{"lang":"en","x_late":"This component updates the  Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"이 구성 요소는 HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어를 업데이트합니다."},{"lang":"cn","x_late":"该组件可更新用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"このコンポーネントは、アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバーをアップデートします"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"551616","datemodified":"2018-10-04T15:53:26","file_list":["cp037781.xml","cpqsetup.exe","cpqsysio64.sys","PICGen9_1.0.9s.hex","SignedImageInstaller64.dll"],"md5sum":"43e10003f21256b4394da0184657a611","name":"cp037781.exe","release":"2018-11-05T00:00:00","revision":"1","sha1sum":"12d4158d8a4830d6df28229489fb1802238b4742","size":"538KB","target_guids":[],"type_of_change":"0","version":"1.0.9(I)"}],"id":{"product":"fdcd2417f5b44570a83d4b1a96ea2478","version":"713c43e07cd74641a292dcc844f52f57"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired components&nbsp;to be updated in the directory, \\packages on the USB key. To use with HPE SUM 7.6.0 or earlier, place the components in \\hp\\swpackages on the USB Key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p>This component can only be executed on Windows x64.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。HPE SUM 7.6.0またはそれ以前のバージョンを使用するには、\\hp\\swpackages内のコンポーネントをUSBキーにコピーしてください。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br />\n </p>\n\n<p>このコンポーネントは、Windows x64上でのみ実行できます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的 ROM 線上更新 - 適用於 HPE Gen9 伺服器的進階功率限定微控制器韌體"},{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen9 Servers"},{"lang":"ko","x_late":"Windows x64용 온라인 ROM 플래시 - HPE Gen9 서버의 고급 전원 캐핑 마이크로컨트롤러 펌웨어"},{"lang":"cn","x_late":"用于 Windows x64 的在线 ROM 刷新 - 用于 HPE Gen9 服务器的高级功率封顶微控制器固件"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Windows  x64  - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen9サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-02T05:54:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.9(I) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9.  It is not necessary to upgrade with Revision I if a previous component Revision was used to upgrade the firmware to version 1.0.9.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems.  This fix increases the accuracy of the minimum capping value set during POST.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<P><B>Important Notes:</B></P>Ver. 1.0.9(I) contains updates to the component packaging and is functionally equivalent to ver. 1.0.9.  It is not necessary to upgrade with Revision I if a previous component Revision was used to upgrade the firmware to version 1.0.9.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Addresses an issue in which the minimum power capping value was incorrectly being calculated on certain systems.  This fix increases the accuracy of the minimum capping value set during POST.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U16","value":"HP ProLiant SE2160w Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U19","value":"HPE ProLiant XL420 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"}],"sw_keys":[{"name":"PowerPIC-Gen9","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver provides Windows 2012/2012 R2 x64, Windows server 2016/2019 support for:\n Dynamic Smart Array B140i Controller."},{"lang":"ja","x_late":"このドライバーは、Windows 2012/2012 R2 x64およびWindows Server 2016/2019サポートを提供します。Dynamic SmartアレイB140iコントローラー。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"1430104","datemodified":"2020-02-27T14:20:52","file_list":["cp042594.xml","cpqsetup.exe","generic.dll","HPpSA.sys","hpsa3.cat","HPSA3.inf","Hpsa3.sys","hpsa3co002.dll","install.xml","libsa3.sys"],"md5sum":"a598c94b88b84be9ef2d454a519473d4","name":"cp042594.exe","release":"2020-02-27T14:19:07","revision":"0","sha1sum":"f74f2703dd0baf180c36079e4a3c165e79b642bd","size":"1MB","target_guids":[],"type_of_change":"1","version":"62.16.2.64"}],"id":{"product":"78fc77876f754f93b5ef96248fa664b1","version":"ae53a398a9c74968aef2d220f2d67d15"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n\n<p><strong>注： </strong>Microsoft kb #2031031について(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), ユーザーはUSB インストールが終わるまではUSBを削除したり、取り外したりすることはできません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Dynamic Smart Array B140i Controller Driver for 64-bit Microsoft Windows Server 2012/2012 R2/2016/2019 Editions"},{"lang":"ja","x_late":"Dynamic SmartアレイB140iコントローラードライバーfor 64ビットMicrosoft Windows Server 2012/2012 R2/2016/2019 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Storage Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-04T09:20:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved integration with Smart Update Manager.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix error handling of AHCI reported Fatal errors with NCQ and Non-NCQ commands in SATL potentially causing RAID stack timeouts and excessive read/write command timeouts leading to SCSI bus reset with M.2 SSD drives configured with SW RAID.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"","value":"HP SL6700 Chassis"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"hpsa3.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP0."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP0で動作するQLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロードのためのARP/DHCPサポートを提供するHPE QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"99306","datemodified":"2019-10-25T06:40:27","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio/component.xml"],"md5sum":"4676db3c5f99fba6cd943622d59034c8","name":"iscsiuio-2.11.5.13-3.sles15sp0.x86_64.rpm","release":"2019-11-01T00:00:00","revision":"2","sha1sum":"6dad75e14a2741d13221bec9b954f03f30dc9637","size":"96KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec563dc806"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"5dd47ac24fdd4dd783c15530b1c51692","version":"de8e1535518d4e4498bc70a5ea77a4a1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-12T15:26:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n"},{"curr_enhancements_x_late":"<p>This product no longer supports ProLiant Blade servers and devices. Blade&nbsp;servers and devices&nbsp;are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-f399524fff61468eae3c47fd12\">HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP0</a>.</p>\n\n<p>This product no longer supports Synergy servers and devices. Synergy servers and devices are now supported by the&nbsp;<a href=\"https://www.hpe.com/global/swpublishing/MTX-cb89d67a37bf4e67b982b1dcc0\">HPE Synergy QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP0</a>.</p>\n","curr_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iscsiuio","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.40_02_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.40 (02/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33740102","datemodified":"2021-02-25T12:46:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/A47_2.40_02_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/CP046229.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.40_2021_02_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046229.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046229.scexe"],"md5sum":"ccb96ac4c64699b22a86a5322c36e28e","name":"firmware-system-a47-2.40_2021_02_23-1.1.x86_64.rpm","release":"2021-02-25T12:39:04","revision":"0","sha1sum":"0b985dc66ecc42488e7b6943cd6664854e453a52","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"0","version":"2.40_02-23-2021"}],"id":{"product":"4a7391c65f0b46d485ea7105b1cfb339","version":"e9bca1ac7c864024a1a5d1aab3e43da9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-04T22:41:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"Added support for AMD EPYC 7003 processors.<p>Added support for Direct Liquid Cooling solution.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.<p>Added a new BIOS/Platform Configuration (RBSU) for Platform RAS Policy to control the Platform Resiliency and Serviceability (RAS) policy. This option controls whether platform firmware or the operating system has control of corrected error handling and reporting.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>HPE ProLiant XL675d Gen10Plus CPLD version 0F<p>HPE Apollo 6500 Gen10 Plus Chassis CPLD version 0909<P><B>Problems Fixed:</B></P>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该x64智能组件为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此 x64 智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 及 P822"},{"lang":"ko","x_late":"이 x64 스마트 구성 요소는 다음과 같은 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラー：SmartアレイP220i, P222, P420i, P420, P421, P721m, およびP822のファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"7103448","datemodified":"2018-10-03T12:12:19","file_list":["746374726C00.firmware.bin.fw","747365700069443232323073620076312E303200.Baz-102.fuf.fw","cp037741.xml","cpqsetup.exe","d2220sb.bin.fw","setup.dll"],"md5sum":"62ce24341b0d1fe2a8e765b4bad36a05","name":"cp037741.exe","release":"2018-10-03T17:05:03","revision":"0","sha1sum":"ef0014c0f0e663541d06676b0740b97f03a1ef08","size":"6MB","target_guids":[],"type_of_change":"1","version":"8.32"}],"id":{"product":"4998c3a06d0e4ed8ac22e37618080a1f","version":"dc0fa2598792465d8d5eaab1e2679052"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HP Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"cn","x_late":"<p><strong>要从目标服务器上的 Windows 操作系统更新固件：</strong></p>\n\n<ul>\n\t<li>将 Smart Component 存放到一个临时目录中。</li>\n\t<li>双击 Smart Component。</li>\n\t<li>按照 Smart Component 提供的说明执行操作。</li>\n\t<li>如要让更新立即生效，请重新启动系统。</li>\n</ul>\n\n<p><strong>如要通过 HP ProLiant服务包 </strong><strong><a href=\"http://www.hp.com/go/spp\">使用 HP智能升级管理器 </a><strong>：</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>将更新使用的目标固件放在 \\SPP20xxxxx\\hp\\swpackages 目录中</li>\n\t<li>找到在 ISO 根位置中发现的 Start.html</li>\n\t<li>打开支持的浏览器中的 html 文件</li>\n\t<li>按照屏幕上的说明操作</li>\n</ul>\n\n<p> </p>\n"},{"lang":"tw","x_late":"<p><strong>若要在目標伺服器上從 Windows 作業系統更新韌體：</strong></p>\n\n<ul>\n\t<li>請將智慧型元件置於暫存目錄中。</li>\n\t<li>在智慧型元件上連按兩下。</li>\n\t<li>請依照智慧型元件所提示的相關指示進行。</li>\n\t<li>重新啟動系統，使更新立即生效。</li>\n</ul>\n\n<p><strong>若要從  </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Service Pack for ProLiant (適用於 ProLiant 的服務套件) </a><strong> 中使用 HP Smart Update Manager (HP 智慧型更新管理器)：</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>將想要更新的韌體放入目錄 \\SPP20xxxxx\\hp\\swpackages</li>\n\t<li>尋找 ISO 的 root 中發現的 Start.html</li>\n\t<li>用支援的瀏覽器開啟 html 檔案</li>\n\t<li>遵循畫面上的說明</li>\n</ul>\n\n<p> </p>\n"},{"lang":"ko","x_late":"<p><strong>대상 서버의 Windows 운영 체제에서 펌웨어를 업데이트하는 방법:</strong></p>\n\n<ul>\n\t<li>스마트 구성 요소를 임시 디렉터리에 저장합니다.</li>\n\t<li>스마트 구성 요소를 더블 클릭합니다.</li>\n\t<li>스마트 구성 요소의 설명에 따라 진행합니다.</li>\n\t<li>업데이트를 바로 적용하려면 시스템을 다시 부팅해야 합니다.</li>\n</ul>\n\n<p><strong>HP Service Pack for ProLiant을 통해  </strong><strong><a href=\"http://www.hp.com/go/spp\">HP Smart Update Manager를 사용하는 방법: </a><strong>:</strong></strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>업데이트하려는 펌웨어를 \\SPP20xxxxx\\hp\\swpackages 디렉터리에 저장합니다.</li>\n\t<li>ISO의 루트에 있는 Start.html을 찾습니다.</li>\n\t<li>지원되는 브라우저에서 html 파일을 엽니다.</li>\n\t<li>화면의 설명에 따라 진행합니다</li>\n</ul>\n\n<p> </p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant</a>からHP Smart Update Managerを使用するには、以下の手順に従ってください。</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるStart.htmlを選択します。</li>\n\t<li>htmlファイルをサポートされているブラウザーで開きます。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"面向 Windows (x64) 的在线 ROM 刷新组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 - 智慧型陣列 P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m, P822"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-29T17:12:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added HPE Digital Signature</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Improved Integration with Smart Update Manager</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"cn","x_late":"驱动程序 - 视频"},{"lang":"ja","x_late":"ドライバ - ビデオ"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eHビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"1604072","datemodified":"2019-07-19T14:20:34","file_list":["cp038691.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO.inf","mxg2hdo64.cat","MxG2hDO64.sys"],"md5sum":"a072ee5975b6a7bee9c041dbced9f0a0","name":"cp038691.exe","release":"2019-07-19T14:19:02","revision":"0","sha1sum":"662ad48d18afb2efd4ebf96f3b6285c89422240d","size":"1MB","target_guids":[],"type_of_change":"0","version":"9.15.1.224"}],"id":{"product":"d90597ae6e7441a698018da6a13176bc","version":"e5fc3b642cf5449d99c1cb8ba85bc66f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"Matrox G200eH Video Controller Driver for Windows Server 2012 and Server 2012 R2"},{"lang":"ja","x_late":"Matrox G200eHビデオコントローラードライバー for Windows Server 2012および2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0533","subdev":"330E","subven":"103C","target_guid":"","type":"pci","ven":"102B"},{"dev":"0533","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-09-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Improved video performance compared to the 9.15.1.174 release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix for random screen corruption when changing resolution that could occur with driver versions 9.15.1.184 and 9.15.1.218.</li>\n\t<li>Fix for a display freeze that could occur when running the Windows Display Diagnostics tool (dispdiag.exe).</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models:MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルにファームウェアを提供します：MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16774654","datemodified":"2021-01-28T10:51:39","file_list":["/CP045677_BUILD_4.data","/CP045677.vmexe","/CP045677.vmexe64","/CP045677.vmfile","/CP045677_VMw.zip","/CP045677.xml","/payload.json","/CP045677_VMw.zip/index.xml","/CP045677_VMw.zip/vendor-index.xml","/CP045677_VMw.zip/metadata.zip","/CP045677_VMw.zip/vib20/CP045677/HPE_bootbank_CP045677_HPD3.4-7.0.0.15843807.vib","/CP045677_VMw.zip/metadata.zip/vendor-index.xml","/CP045677_VMw.zip/metadata.zip/vmware.xml","/CP045677_VMw.zip/metadata.zip/vibs/CP045677--9015280790130932372.xml","/CP045677_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045677_HPD3.4-7.0.0.15843807.xml"],"md5sum":"bb4bbcbfa61971bbe860ad9b117dc09e","name":"CP045677.zip","release":"2021-01-28T10:49:04","revision":"0","sha1sum":"f7946eacd25c95c79cd41b76db011b34d7d9289f","size":"15MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP045677","version":"HPD3.4-7.0.0.15843807"}]}],"id":{"product":"22bf9e4ced19410ca8b8850245112a89","version":"ffaf778df3c840f69d3fec6f2cd4fc32"},"installation":{"command":"CP039420.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:15:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3327200","datemodified":"2021-01-28T09:20:25","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"e5028b2f6f043c20a9bd1c3175a3eb7c","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-28T09:11:06","revision":"0","sha1sum":"d9e68ac5a87f67b2e015d598cf01ea918b173a38","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"676bdef4b7644815a191aa651f44dc5d","version":"0dd0d7a56b7b4b0d8fd452ebc0303ad7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles11sp3.x86_64.rpm</p>\n\n<p>4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。</p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e brcmfcoe-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 update 9 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:35:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1259.0</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<table>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<ul>\n\t\t\t\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n\t\t\t</ul>\n\t\t\t&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4099519","datemodified":"2021-01-09T01:39:40","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"0bcb2e1b8f6bc6a7d89191d8f3c35abe","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T01:29:05","revision":"0","sha1sum":"2c2e7889f03dd48f7fd63b00e389b691cfc7a6c7","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4216415","datemodified":"2021-01-09T01:35:56","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"0a1109a8720d402c1ef70378ce2a8e8b","name":"hp-ixgbe-kmp-default-5.9.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T01:29:05","revision":"0","sha1sum":"bc8838c6ddbf850ce4504e33bd99a566bb17fbe5","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"926b8a90acf147dd8614685a9453a0ed","version":"1dab5bf9eb75410999037da04153edc7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 9 x86_64."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"24697","datemodified":"2021-02-11T00:28:19","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"1daeba3a63d6f205d1e6a31ab2020f57","name":"libbnxt_re-218.0.7.0-rhel7u9.x86_64.rpm","release":"2021-02-11T00:25:03","revision":"0","sha1sum":"d683f7c71346c45dccca5a39ec6b836b47cb112b","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"1ff674590ea54295a0a402207a50999a","version":"8a623fc47ccb4689921f70c98423a92e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 9"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n     </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n     None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:  </strong><br />\n     None <br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>     </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2771376","datemodified":"2020-12-16T12:13:43","file_list":["cp045574.xml","cpqsetup.exe","GPM863G1.rel","payload.json","setup.dll"],"md5sum":"3a4c5387672225f2f15b13498671e55a","name":"cp045574.exe","release":"2020-12-16T12:05:04","revision":"0","sha1sum":"12dbd0360e9fa0b46a8296b74c0fd3cb23fffc92","size":"2MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3aebaee5a0504648985c2d89d7e4e8d9","version":"1ccd5db7ab204de39c63a7259172160f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:59:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1943976","datemodified":"2020-12-02T14:16:16","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio/mdev","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio/mdev/i915.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio/mdev/kvmgt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio/mdev/mdev.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"abd47fbffbeec57080a31a04898dfc3a","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.2.2.4.1.sles12sp4.x86_64.rpm","release":"2020-12-02T12:31:04","revision":"0","sha1sum":"696c2f107d22c7a0f3fae1bc1afd1270cd24c6a6","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"},{"bytes":"1933441","datemodified":"2020-12-02T14:19:28","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"532ca22945770fa271d9d55759375da8","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles12sp4.x86_64.rpm","release":"2020-12-02T12:31:04","revision":"0","sha1sum":"dde88e1795e57178c033b5c2fdc4f3104c6f010e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9"}],"id":{"product":"eff3fb3bc296490cb954337b0cfc0052","version":"4ad38537a1c84790ba61b0c31ed58589"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.sles12sp4.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.2.2.4.1.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:40:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3015456","datemodified":"2020-12-16T17:44:44","file_list":["cp045548.xml","cpqsetup.exe","payload.json","setup.dll","TTMRESD9.REL"],"md5sum":"83d044157d0fd43766ab607b06debfcf","name":"cp045548.exe","release":"2020-12-16T17:33:09","revision":"0","sha1sum":"54a061b897050c65f1fe877097a631a1ea60445a","size":"2MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"705c5706f7b64a23bc5fcf7fbd4a5be7","version":"1f4cb3994034431591590d05d214c6a3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:48:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1054791","datemodified":"2021-01-09T00:30:27","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"eef03cea783070a730ece6f1c6831013","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-09T00:17:05","revision":"0","sha1sum":"cf07545a9209073daf61b4bd7332fb06980a81f7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1027253","datemodified":"2021-01-09T00:28:07","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"e258a73037027999efdc23d663455fa8","name":"hp-ixgbevf-kmp-default-4.9.3_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-09T00:17:05","revision":"0","sha1sum":"a66a00efb5ae308d575966266f276bd7f78e45b9","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"cff92813aa394a808304dff72295152b","version":"7ec0ddeec2514f92a584d20b278cfa37"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6116376","datemodified":"2020-11-03T13:32:57","file_list":["./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/CP046151.xml","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/P85_2.80_10_16_2020.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-p85-2.80_2020_10_16-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP046151.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP046151.scexe"],"md5sum":"ce8d35ff49309af772bad0e0084af575","name":"firmware-system-p85-2.80_2020_10_16-1.1.i386.rpm","release":"2020-11-03T13:23:10","revision":"0","sha1sum":"872317020db3209cdd9d2f64150ae235fc792259","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"68ce71d480544726b13cf1bf182ff422","version":"33ba810b1e7a4e6089ce1ea388348ad2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen9 (P85) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen9(P85)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Oracle Linux 6 (AMD64/EMT64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Oracle Linux 7","platform":"Oracle Enterprise Linux","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T09:13:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains the latest support for Red Hat Enterprise Linux 8.x Server. Ver. 2.76_10-21-2019(B) contains updates to the firmware packaging and is functionally equivalent to ver. 2.76_10-21-2019.&nbsp; It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 2.76_10-21-2019.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-0151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"}],"sw_keys":[{"name":"P85","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify various chipset devices."},{"lang":"ja","x_late":"このコンポーネントは、各種のチップセットデバイスを認識するための、ドライバーなしのINFをインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"cn","x_late":"服务器选项"},{"lang":"ja","x_late":"サーバ オプション"}]}],"documentation":[],"files":[{"bytes":"607888","datemodified":"2019-09-26T01:32:14","file_list":["broadwell-de.cat","Broadwell-DESystem.inf","cp040885.xml","cpqsetup.exe","haswelle.cat","HaswellESystem.inf","hpgen9.dll","hpgen9inst.dll","lynxpoint.cat","LynxPointSystem.inf","null_heci.cat","NULL_HECISystem.inf","sunrisepoint-h.cat","SunrisePoint-HSystem.inf","wellsburg.cat","WellsburgSystem.inf"],"md5sum":"8895eb15a08318f8e5d9723520f39936","name":"cp040885.exe","release":"2019-09-26T01:31:02","revision":"0","sha1sum":"3776ba9c606a98180769c67cb23d02dd69cf9393","size":"593KB","target_guids":[],"type_of_change":"0","version":"10.1.17969.8134"}],"id":{"product":"fcc983919bfc411fa0536a632fac1e38","version":"cb8d45c15706411e8416dae1af18c4a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。 ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。 \n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen9 Chipset Identifier for Windows Server 2012 R2 to Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"A123","subdev":"8165","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"A123","subdev":"7270","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D22","subdev":"8030","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D22","subdev":"21EB","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"2F20","subdev":"18A8","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"6F28","subdev":"21EA","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Updated to match the latest version available from Intel for the devices supported by this component.</li>\n\t<li>Removed Windows Server 2012 to align operating system support with the production Service Pack for ProLiant.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"hpgen9.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\HPGEN9"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2899248","datemodified":"2020-12-17T11:50:40","file_list":["cp045507.xml","cpqsetup.exe","payload.json","setup.dll","TA13SXD5.rel"],"md5sum":"c053847d54a910de01568353f3a83c0a","name":"cp045507.exe","release":"2020-12-17T11:35:15","revision":"0","sha1sum":"0d56a03d635e1d54b3eb420709193961ad54fb1d","size":"2MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8de9ca424f8f4678aeecd66cdfe60068","version":"119129998bb641aba1a4c18b486640bf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:34:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn and ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Intel ixnおよびixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"954880","datemodified":"2021-02-01T06:27:57","file_list":["cp045152.xml","cpqsetup.exe","cp_data.xml","install.xml","nicco5.dll","nicdrvr.dll","NicInVXN.dll","vxn64x64.cat","vxn64x64.din","vxn64x64.inf","vxn64x64.sys","vxnmsg.dll"],"md5sum":"1e6efa53e7ed4d79e65b511f05a1e42f","name":"cp045152.exe","release":"2021-02-01T06:11:04","revision":"0","sha1sum":"fdf260769c9cc48b3ea7ff45595077d0d6ed41cd","size":"932KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5befedc7"],"type_of_change":"0","version":"1.2.199.0"}],"id":{"product":"d431c0fab9a74249883baa6f26e0c6aa","version":"5fd35e9bf09f465d81dd6c8916162e91"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Intel vxnドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"vxn64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: EH0600JDYTN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>None.</li>\n</ul>\n"}],"files":[{"bytes":"5536947","datemodified":"2020-12-13T09:01:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/CP045401.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/HKFL4CD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045401.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045401.scexe"],"md5sum":"19dd362cf8056ec2693151732899c63f","name":"firmware-hdd-f3faa195ff-HPD7-7.1.x86_64.rpm","release":"2020-12-13T08:48:05","revision":"0","sha1sum":"deb293e7cf2d290a849e0f7074d847d5f0274761","size":"5MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"dc8e1d549b6c46c4a9bd046b4dd1950e","version":"4668f8028f6b4d53af0f7ecd8a2d0e69"},"installation":{"command":"CP040340.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:13:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read. </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"5551182","datemodified":"2019-08-07T15:57:11","file_list":["./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/.cpq_package.inc","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/.setup","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/CP040772.xml","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/U26_2.66_07_19_2019.signed.flash","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/hpsetup","./usr/lib/i386-linux-gnu/firmware-system-u26-2.66_2019_07_19-1.1/setup","./usr/lib/i386-linux-gnu/hp-scexe-compat","./usr/lib/i386-linux-gnu/hp-scexe-compat/CP040772.scexe","./usr/lib/i386-linux-gnu/scexe-compat","./usr/lib/i386-linux-gnu/scexe-compat/CP040772.scexe"],"md5sum":"ca5b885189b4b13f38fd154010adbd24","name":"firmware-system-u26-2.66_2019_07_19-1.1.i386.rpm","release":"2019-08-07T15:52:03","revision":"0","sha1sum":"8ebf09c2db967ab611ed15cfd14e409ca6689c66","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.66_07-19-2019"}],"id":{"product":"2292648d1a8a4c6db1c16819d8335faf","version":"cee280b6ccca4b71b1af9d8eba25e0ee"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component will fail if it is unable to communicate with iLO.&nbsp; This can occur if HPE ProLiant Agentless Management Service (<strong>AMS</strong>) and HPE SNMP Agents (<strong>SNMP Agents</strong>) are both running.&nbsp; HPE does not recommend running AMS and the SNMP Agents at the same time.&nbsp; If an &quot;iLO device not found&quot; error occurs, stop AMS or the SNMP Agents, and run the flash component again.<br />\n<br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager 8.0.0 or later, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、iLOとの通信ができない場合に失敗します。  これは、HPE ProLiant Agentless Management Service (<strong>AMS</strong>)およびHPE SNMPエージェント(<strong>SNMP Agents</strong>)の両方が実行されているときに発生します。  HPEでは、AMSおよびSNMPエージェントを同時に実行させないことを推奨します。  「iLO device not found」エラーが発生した場合、AMSまたはSNMPエージェントを停止させて、再度フラッシュコンポーネントを実行します。<br />\n<br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISO上のSmart Update Manager 8.0.0以降を使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant EC200a (U26) Server/HPE ProLiant Thin Micro TM200 (U26) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12 for ARM","platform":"suse_linux_enterprise_server_aarch64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-08-24T23:01:21","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>Updated the Intel processor microcode to the latest version.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"<p>None</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for an Intel sighting where the system may experience a machine check after updating to the latest System ROM which contained a fix for an Intel TSX (Transactional Synchronizations Extensions) sightings. The previous microcode was first introduced in the v2.62 System ROM. This issue only impacts systems configured with Intel Xeon&reg; D-1500 processors. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"}],"sw_keys":[{"name":"U26","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"914336","datemodified":"2019-10-24T20:47:51","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp039932.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"ed3b97052e6341ef1f2550d293795307","name":"cp039932.exe","release":"2019-10-24T20:34:04","revision":"0","sha1sum":"2ad030e4582c7eb56db125ce02ac69385f2174cd","size":"892KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"36e4d61e9116490288f4da49e28def20","version":"2c841fddfbb64e23bec22456fe365dbb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11583048","datemodified":"2021-01-28T11:58:39","file_list":["cp046641.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_2.42_01_23_2021.signed.flash"],"md5sum":"8132a6080ea2795275d6a65aa9e3e76d","name":"cp046641.exe","release":"2021-01-28T11:56:05","revision":"0","sha1sum":"6272e02d99b3a3a34f7acec1c0e07708d46e0c9a","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"c94eb717d55e4213952a8c5723962404","version":"c248489df93f409f8f1704814d6cf1ef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30116","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30052","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 10/25GbE 2P SFP28 MCX512F, HPE 10/25GbE 2P SFP28 MCX562A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 6.7."},{"lang":"ja","x_late":"このパッケージには、ESXi 6.7上のHPE 10GbE 2P SFP + MCX4121A、HPE 10GbE 2p SFP + MCX4621A OCP3、HPE 10/25GbE 2P SFP28 MCX512F、HPE 10/25GbE 2P SFP28 MCX562A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (P13188-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (P10112-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"36498824","datemodified":"2021-02-03T03:12:23","file_list":["/CP045141.vmexe","/CP045141.vmfile","/CP045141_VMw.zip","/CP045141.xml","/payload.json","/CP045141_VMw.zip/index.xml","/CP045141_VMw.zip/vendor-index.xml","/CP045141_VMw.zip/metadata.zip","/CP045141_VMw.zip/vib20/CP045141/HPE_bootbank_CP045141_1.0.1-6.7.0.7535516.vib","/CP045141_VMw.zip/metadata.zip/vendor-index.xml","/CP045141_VMw.zip/metadata.zip/vmware.xml","/CP045141_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045141_1.0.1-6.7.0.7535516.xml","/CP045141_VMw.zip/metadata.zip/vibs/CP045141--1405020143341953169.xml"],"md5sum":"515d13c20627293a88e92a3c34163328","name":"CP045141.zip","release":"2021-02-03T03:18:05","revision":"0","sha1sum":"900dd6ea4f7d6a313649946d3cd5d7130597d15e","size":"34MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30116","a6b1a447-382a-5a4f-15B3-101715B30052","a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.4","vib_list":[{"name":"CP045141","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"e880844ad1a74e7f8866fa15b1ed3ae6","version":"e1c64836e7654865bd0f860ada5ac18d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 6.7）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:55:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.27.4000:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.27.2008:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>New Feature and Changes in Version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.29.1016:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<p><strong>New Feature and Changes in Version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Ethernet wqe_too_small Mode: A per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats:</li>\n\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused packets to drop due to header size issues and/or failing checks. This issue was caused due to a Linux issue that caused VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) might take longer than when MKEY_BY_NAME was disabled.</li>\n\t<li>In rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>An issue that caused the device to go to dead IRISC as one of the firmware semaphores could not be released when a speed change or port state change was triggered.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the eth_wqe_too_small counter to count ODP page faults.</li>\n\t<li>A low performance was observed after enabling the RoCE Accelerator capability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD8"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3018856","datemodified":"2020-12-16T09:22:30","file_list":["cp046242.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06scHPD8.REL"],"md5sum":"9809ad002dd0742765261583ed01cdc3","name":"cp046242.exe","release":"2020-12-16T09:11:04","revision":"0","sha1sum":"da85adacbd54f7f5e365b7c1577d3b97db6f246c","size":"2MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"0c95f7c054f047b69fbfe7c93264a982","version":"165b632ec89b4fb793c47ad6ae7acf76"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000JWJRQおよび MB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-05T16:00:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protections against hangs in certain corner cases, and cleans up some error handling and command behavior issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEBTP Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000GEBTPドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5063364","datemodified":"2020-12-13T13:54:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/CP045438.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/HAHC6FG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045438.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045438.scexe"],"md5sum":"b7d3fc60e822b117f51f97dc81419c16","name":"firmware-hdd-3243fce9a0-HPG4-8.1.x86_64.rpm","release":"2020-12-13T13:43:08","revision":"0","sha1sum":"d4c47d276b3c3dac9da880abc119332165d8c270","size":"4MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"aa6bec5edbc1481bba28cd93023707d3","version":"8d00b8c4469341cfb065995caa857b19"},"installation":{"command":"CP040321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEBTP Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA4_FH_2p24_PLDMoMCTP_800059D9.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"2.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td>\n\t\t\t<td>800059D9</td>\n\t\t\t<td>1.2839.0</td>\n\t\t\t<td>2.24</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2839.0 includes: Intel(R) Boot Agent ICE v2.2.01 &amp; UEFI x64 100 gigabit driver v2.2.07.</p>\n"}],"files":[{"bytes":"10516253","datemodified":"2021-01-21T10:25:36","file_list":["HPE_E810_XXVDA4_FH_2p24_PLDMoMCTP_800059D9.HPb","HPE_E810_XXVDA4_FH_2p24_PLDMoMCTP_800059D9.xml","payload.json"],"md5sum":"b5f898b13b826c554969b6bb6bae237c","name":"HPE_E810_XXVDA4_FH_2p24_PLDMoMCTP_800059D9.fwpkg","release":"2021-01-21T10:21:04","revision":"0","sha1sum":"c0ae8b44f803eb561a0b9fffcf39bca7a049ede4","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159380860005"],"type_of_change":"1","version":"2.24"}],"id":{"product":"955cffa0d4fe4b76923c0ea7afeca0bf","version":"3ff52e73e0ec4103a3cc3ad83afdfb80"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 2-port SFP28 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"INTEL_E810_XXV4_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_1002-843400-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.1002"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872723-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.29.1016"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_29_1016-872725-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.1002</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"7149234","datemodified":"2021-01-25T07:03:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/CP045139.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw/fw-ConnectX4-rel-12_28_1002-843400-B21_Ax_Bx-UEFI-14.21.16-FlexBoot-3.6.101.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-872723-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw/fw-ConnectX5-rel-16_29_1016-872725-B21_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045139.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045139.scexe"],"md5sum":"4ff7f85788924e16264486c77e325a82","name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.7-1.1.x86_64.rpm","release":"2021-01-25T07:00:04","revision":"0","sha1sum":"c90bdf561ebd21ad91cf56f5a4cfee206c0d85dc","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.7"}],"id":{"product":"f148b53c7b96447699a0d01706827644","version":"e98b14b335c2497f9d9247e43badcea8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:55:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.27.4000:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.27.2008:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observered while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.1002:</strong></p>\n\n<p>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n<br />\n<strong>New Feature and Changes in Version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><br />\n<strong>Firmware for the following devices are updated to 16.29.1016:</strong></p>\n\n<p>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of the cluster.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compared to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats: Responder Mini CQE With Flow Tag Layout Responder Mini CQE With l3_l4_info Layout</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT&nbsp;command.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>A new counter per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>PCIe Rx modifications to prevent the adapter cards from disappearing from the system.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n\t<li>cq_overrun counter. The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>[Beta]&nbsp;Enabled the capability to allow Virtual Functions to send Pause Frames packets.</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that prevented&nbsp;VXLAN packets with svlan/ cvlan tag from being matched.</li>\n\t<li>An issue that caused the&nbsp;eth_wqe_too_small counter to count&nbsp;ODP (On-Demand Paging) page faults.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>&nbsp;Ani ssue that resulted in low performance after enabling the RoCE Accelerator capability. Note:&nbsp;The fix is available when all ports are set as Ethernet.&nbsp;</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>The chassis manager calculation for Multi-Host and Socket-Direct adapter cards to allow running NC-SI commands by the chassis manager BMC. Now the chassis manager is count as BMC with index 0, regardless of how many BMC there are.</li>\n\t<li>An issue that caused&nbsp;the device to go to down IRISC as one of the firmware semaphores could not be released&nbsp;when a speed change or port state change was triggered.&nbsp;</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 12.28.1002:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"840696","datemodified":"2020-06-03T02:29:50","file_list":["cp042038.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"md5sum":"7724450bda7b0525d4efc261a4c3d726","name":"cp042038.exe","release":"2020-06-03T02:16:09","revision":"0","sha1sum":"73b004740258bfbd18854c5e4bdb245b06f95379","size":"820KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"b88ebb63a68747808884160b11c000eb","version":"a1d6c87c6f5846a992a7a4a2617d15bc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2019"},{"lang":"ja","x_late":"Windows Server 2019用HPE Intel vxsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager（SUM）と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5879816","datemodified":"2020-10-29T18:25:45","file_list":["SignedImageInstaller64.dll","U25_2.80_10_16_2020.signed.flash","cp046196.xml","cpqsetup.exe","cpqsysio64.sys"],"md5sum":"954e928b5d1a3a1391d7dfa4275fdb89","name":"cp046196.exe","release":"2020-10-29T18:08:06","revision":"0","sha1sum":"5c8301a32848e4a35cd25b326976f1a7bd93354f","size":"5MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020"}],"id":{"product":"d4f71c14a668436aace9f00c7057e76e","version":"e1c3dc3aa9974b18b7f7e85eebe8b96f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL270d (U25) Accelerator Tray"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant XL270d (U25) アクセラレータトレイ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-29T18:02:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390.  These issues are not unique to HPE servers.<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"}],"sw_keys":[{"name":"U25","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"cn","x_late":"软件 - 管理"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi CRU Driver Smart Component for ESXi 7.0 includes the latest HPE CRU Driver. The HPE CRU Driver provides hardware memory and PCI Config Space access to HPE Server Configuration tools and firmware flash components."},{"lang":"ja","x_late":"HPE ESXi CRU ドライバー Smartコンポーネント for ESXi 7.0には、最新のHPE CRUドライバーが含まれています。HPE CRUドライバーは、HPEサーバー構成ツールおよびファームウェアフラッシュコンポーネントへのハードウェアメモリおよびPCI構成スペースアクセスを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"21644","datemodified":"2020-06-17T18:54:49","file_list":["/cp044598.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vib20/cru/HPE_bootbank_cru_700.10.16-1OEM.700.0.0.14828939.vib","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vmware.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vibs/cru--3587722627266947823.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/bulletins/cru-driver_700.10.16-1OEM.700.0.0.14828939.xml"],"md5sum":"b15fcccba65f1a201e75668f7235c216","name":"cp044598.zip","release":"2020-06-17T18:54:04","revision":"0","sha1sum":"1062a6263027ebed11f844c940fdd7d86fcde628","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecab5ae383","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6"],"type_of_change":"1","version":"2020.04.01","vib_list":[{"name":"cru","version":"700.10.16-1OEM.700.0.0.14828939"}]}],"id":{"product":"2bca574323fb4462b57e23c3b359f69c","version":"2310590f205e43e0ae97f59492d0a40a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE CRU Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-17T18:45:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Support&nbsp;for VMware ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add new supported servers</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru-driver:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"cru:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_242.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.42"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HP Smart Update Manager."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HP Smart Update Managerと一緒に使用することが出来ます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"33906894","datemodified":"2021-04-06T03:25:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/CP046457.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/ilo5_242.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.42-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046457.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046457.scexe"],"md5sum":"aba0aa9bbc6659e6d0af269c83f1ecde","name":"firmware-ilo5-2.42-1.1.x86_64.rpm","release":"2021-04-06T03:16:08","revision":"0","sha1sum":"15e403452dcc10927dc02af95d217bdbf0e0fb28","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"2","version":"2.42"}],"id":{"product":"8aa4f1e30dfc4417885cea85b551314e","version":"9b6c89640e0948e1b0bafd59a155335c"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from the Linux operating system on target server:</strong><br />\nDownload the SCEXE file to the target server.<br />\nExecute: sh CP0xxxxx.scexe</p>\n\n<p>&nbsp;<strong>To obtain firmware image for updating via iLO user interface, utilities, or scripting interface:</strong><br />\nDownload the SCEXE file to a client running&nbsp;a Linux operating system.&nbsp; Execute: sh&nbsp; CP0xxxxx.scexe&nbsp;--unpack=directory<br />\nThis command will unpack the ilo5_XXX.bin into a user specified &quot;directory&quot;. If the directory does not exist, the unpacker will attempt to create it.</p>\n\n<p><strong>To use HP Smart Update Manager on the Firmware Maintenance CD</strong><strong>:</strong><br />\nPlace the Firmware Maintenance CD on a USB key using the USB Key Creator Utility.&nbsp;<br />\nCopy&nbsp; CP0xxxxx.scexe&nbsp;to /compaq/swpackages directory on the USB Key.<br />\nFollow HP Smart Update Manager steps to complete firmware update.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86)","platform":"red_hat_enterprise_linux_client_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-15T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support to import large sized LDAP CA certificate</li>\n\t<li>Support enablement for latest Intel Persistence Memory</li>\n\t<li>iLO GUI to display the Host Operating System Version</li>\n\t<li>Display platform Resiliency and Serviceability (RAS) policy in iLO GUI</li>\n\t<li>Added standard redfish schema support for Computer System &ndash; Reset, Graceful restart actions&nbsp;</li>\n\t<li>Real CPU temperature is reported in addition to normalized temperature (this feature requires ROM 2.40 version)</li>\n\t<li>Support for Active Health System logging by RDE ( Redfish Device Enablement ) enabled devices</li>\n\t<li>Support alerting feature for RDE ( Redfish Device Enablement ) enabled devices&nbsp;</li>\n\t<li>Ability to control LED for locating direct attached SATA drives</li>\n\t<li>Ability to reset power for direct attached SATA drives&nbsp;</li>\n\t<li>Added write protect setting feature for Liquid cooled Delta/Redstone GPU cards.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>iLO 5 reporting incorrect Power Supply count with iLO 5 v2.10</li>\n\t<li>Continuous logging to IML of a CHIF Error running ESXi with iLO 5 v1.46</li>\n\t<li>Random messages &quot;smad[]: No response from iLO for Hello&quot; seen in certain Operating Systems&nbsp;</li>\n\t<li>Incorrect MAC address shown in iLO for Synergy 4820C network adapter</li>\n\t<li>InfiniBand card not syncing with Oneview in iLO 5 v2.30</li>\n\t<li>Copy/paste may not work for more than 255 characters to VSP terminal in Linux platforms&nbsp;</li>\n\t<li>547FLR / 1100Q NIC may reset to default mode after flashing from 1.48 to 2.xx</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>- Added Server Identity (iLO IDevID, iLO LDevID, System IDevID, System IAK and Platform certificates)&nbsp;<br />\n&nbsp; capability to uniquely identify a server across networks that is cryptographically verifiable<br />\n- EAP-TLS based authentication for onboarding into an 802.1X access-controlled network<br />\n- Enabled support for Intel VROC</p>\n\n<ul>\n\t<li>Device discovery and inventory of VROC SATA Controller and drives attached to it</li>\n\t<li>Firmware inventory of Intel VROC(VMD NVMe RAID) and VROC SATA Controller</li>\n</ul>\n\n<p>- Extend size for firmware versions supported to 48 bytes<br />\n- Liquid Cooling support for Apollo systems<br />\n- Server Platform Services Descriptor verification and recovery<br />\n- Enabled Discovery, Inventory and Thermal support for Pensando Cloud Adapters</p>\n\n<ul>\n\t<li>P41849-B21: Pensando DSP DSC-25 Cld-SP 10/25Gb Card</li>\n\t<li>P41852-B21: Pensando DSP DSC-100 Cld-SP 100Gb Card</li>\n</ul>\n\n<p>- For Synergy, restricted the capability to change below settings.</p>\n\n<p>&nbsp; Note : Changes to these settings can affect communication between One-view and iLO</p>\n\n<ul>\n\t<li>iLO Web service&nbsp;</li>\n\t<li>iLO Web service Non-SSL Port</li>\n\t<li>Web server SSL Port</li>\n\t<li>iLO RIBCL Interface</li>\n</ul>\n","curr_fixes_x_late":"<p>- Corrected Product Name listed under Device Inventory as &quot;NVIDIA Quadro M3000SE&quot;, that was wrongly listed as &quot;Synergy 75W MXM Mezzanine&quot; with iLO firmware v2.16 and higher<br />\n- iLO stops monitoring the second Pensando card after the first one fails with a PCIe error<br />\n&nbsp;</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920/e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_29_1016-P11338-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 6.7."},{"lang":"ja","x_late":"このパッケージには、ESXi 6.7上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート548SFP+アダプター（P11338-B21）</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15755462","datemodified":"2021-02-03T07:15:39","file_list":["/CP045198.vmexe","/CP045198.vmfile","/CP045198_VMw.zip","/CP045198.xml","/payload.json","/CP045198_VMw.zip/index.xml","/CP045198_VMw.zip/vendor-index.xml","/CP045198_VMw.zip/metadata.zip","/CP045198_VMw.zip/vib20/CP045198/HPE_bootbank_CP045198_1.0.1-6.7.0.7535516.vib","/CP045198_VMw.zip/metadata.zip/vendor-index.xml","/CP045198_VMw.zip/metadata.zip/vmware.xml","/CP045198_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045198_1.0.1-6.7.0.7535516.xml","/CP045198_VMw.zip/metadata.zip/vibs/CP045198--2225541766847407455.xml"],"md5sum":"67dcdd82891b8bc3bd7e91ed68fbb8e7","name":"CP045198.zip","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"45d8323d21233b9a87b87ad2a7cb5eab2548aa59","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.4","vib_list":[{"name":"CP045198","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"24a612c609984b6d85fe7fd4ee8bdcc3","version":"c07eb3e84dc2404a968ffb147b972246"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 6.7）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T20:24:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.28.1002:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.28.1002:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</p>\n\n<p><strong>Following New features and Changes are included in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>Added mlxconfig support for power reduction: PCI CAP AUTO_POWER_SAVE_LINK_DOWN\n\t<ul>\n\t\t<li>PCI CAP</li>\n\t\t<li>AUTO_POWER_SAVE_LINK_DOWN</li>\n\t</ul>\n\t</li>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the sent packet to hang while the device entered FLR mode.</li>\n\t<li>Enabled Bar configuration bytewise by applying the write_en bitmask.</li>\n\t<li>A rare case where the the device froze&nbsp;while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance while using the VSC to trigger the send_ring_doorbells.</li>\n\t<li>An error that prevented the completions (CQ) from being completed due to a race condition in the firmware transport error handlers, and the error stressors, where the error stressors would hang the firmware transport error handler flow.</li>\n\t<li>An issue that caused the fragmented IP packets to drop was fixed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11450670","datemodified":"2021-01-27T20:20:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/CP046685.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/U38_2.42_01_23_2021.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.42_2021_01_23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046685.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046685.scexe"],"md5sum":"b4ceac32988a4e3677dede8e5eabf62a","name":"firmware-system-u38-2.42_2021_01_23-1.1.x86_64.rpm","release":"2021-01-27T20:07:05","revision":"0","sha1sum":"d058a740957bee724c32a410487ddd439c83bc4e","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"7ebf7b3b32234babb113c6746f09f68e","version":"f62ab96edcaf45bd90a727afcd989a5c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-22T20:46:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers.</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.<p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC+1). This support also requires the latest version of iLO Firmware, version 2.40 or later.","curr_fixes_x_late":"<P><B>Important Notes:</B></P>None<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.<p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.<p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.<p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.<p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.<P><B>Known Issues:</B></P>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.42_01_23_2021.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.42 (01/23/2021)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11581128","datemodified":"2021-01-28T11:54:34","file_list":["cp046644.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_2.42_01_23_2021.signed.flash"],"md5sum":"4fe18673c64ac79c22897e840af8362d","name":"cp046644.exe","release":"2021-01-28T11:52:12","revision":"0","sha1sum":"01f60874a40a9a6f0aee1f8fe4d9ee3cc51c6568","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.42_01-23-2021"}],"id":{"product":"bf6c1988a6474823969dd84808070288","version":"013183a1a8c349be8e048b9ce56a25fc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-21T03:16:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM to allow for an increased amount of 64-bit Memory Mapped I/O available for third party options cards.  <p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.  <p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the system ROM includes updates to the Intel Memory Reference Code which may help improve memory stability for systems configured with two DIMMs per channel. Please consult Intel sighting documentation for more details on the improvements included in the Intel IPU.2.2020 release. This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-0381. The Intel microcode patches included in this release are version 0x02006A08 (CPUID 50654), 0x04003003 (CPUID 50656) and 0x05003003 (CPUID 50567). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0587, CVE-2020-0588, CVE-2020-0590, CVE-2020-0591, CVE-2020-0592 and CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8739, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which addressed an issue where the system may get stuck in a reboot loop during memory training. This issue was introduced with the v2.30 System ROM. This issue was not unique to HPE servers</p>\n\n<p>Addressed an issue where the memory locality of the ACPI SLIT table was not being created properly. In rare cases, the incorrect ACPI SLIT values could cause unexpected impacts to system performance. This issue was introduced in the v2.10 version of the System ROM and was not seen with previous versions of the System ROM.</p>\n\n<p>Addressed an issue where NVMe Hot-plug and Hot-add would not function properly with VMware. This issue did not impact NVMe Hot-plug or Hot-add with other operating systems.</p>\n\n<p>Addressed an issue where the system would not properly call out a memory replacement event in the Integrated Management Log (IML) if an uncorrected memory failure occurred during an Advanced Double DRAM Device Correction (ADDDC) sparing operation. This fix only impacts the incorrect logging of these events and does not impact the normal operation of the system in terms of causing uncorrected memory failures or causing any change to the operation of A3DC functionality. This issue only impacts systems configured for fast Fault Tolerant Memory Mode (ADDDC).</p>\n\n<p>Addressed an issue where the BIOS/Platform Configuration (RBSU) option for the Extended Memory Test could be automatically disabled after a system reboot. This issue was introduced with the v2.30 System ROM and was not seen with earlier version of the System ROM.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Updated the support for Fast Fault Tolerant Memory Mode (ADDDC) to improve system uptime.</p><p>Added support to the BIOS/Platform Configuration (RBSU) Time Zones to add Dublin/London (UTC 1). This support also requires the latest version of iLO Firmware, version 2.40 or later.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception under heavy stress with short loops of instructions. This may result in a machine check exception in Bank 3 with MSCOD = 0080 and MCACOD = 0400h, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). This issue only impacts 2nd generation Intel Xeon Scalable Performance processors. This issue is not unique to HPE servers.</p><p>This revision of the System ROM includes the latest revision of the Intel microcode which provides a fix for a potential machine check exception when high levels of posted interrupt traffic occurs on PCIe. This may result in a machine check exception in Bank 9, 10 or 11 with MSCOD = 000Ch, as logged in the Integrated Management Log (IML). The Intel microcode patches included in this release are versions 0x02006A09 (CPUID 50654), 0x04003005 (CPUID 50656) and 0x05003005 (CPUID 50567). As part of this change, a new BIOS/Platform Configuration (RBSU) option in Advanced Performance Options has been added to allow a customer to disable this mitigation. This issue is not unique to HPE servers.</p><p>Addressed an extremely rare issue where the Real Time Clock may become corrupted on a server boot. This was typically seen as an unexpected change to the RTC Year field but could impact other parts of the Date and Time. This issue is not unique to HPE servers.</p><p>Addressed an issue where the Extended Memory Test is not run when configured in BIOS/Platform Configuration (RBSU) to Enabled.  Note that this option is Disabled by default.  This issue was introduced in the v2.40 revision of the System ROM.</p><p>Addressed an issue where the server system fans may run higher than anticipated when a server is configured with AHCI SATA drives.</p><p>Addressed an issue where a bad LRDIMM memory device could be mapped out but was not properly reported in the Integrated Memory Log (IML). This issue only impacted systems configured with LRDIMMs.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GVYZBおよびMB4000GVYZAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17136145","datemodified":"2021-01-28T15:53:55","file_list":["/CP045665_BUILD_4.data","/CP045665.vmexe","/CP045665.vmexe64","/CP045665.vmfile","/CP045665_VMw.zip","/CP045665.xml","/payload.json","/CP045665_VMw.zip/index.xml","/CP045665_VMw.zip/vendor-index.xml","/CP045665_VMw.zip/metadata.zip","/CP045665_VMw.zip/vib20/CP045665/HPE_bootbank_CP045665_HPG4.4-7.0.0.15843807.vib","/CP045665_VMw.zip/metadata.zip/vendor-index.xml","/CP045665_VMw.zip/metadata.zip/vmware.xml","/CP045665_VMw.zip/metadata.zip/vibs/CP045665--837090065737588225.xml","/CP045665_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045665_HPG4.4-7.0.0.15843807.xml"],"md5sum":"cc606a7044f0200189c81d4ab884f3df","name":"CP045665.zip","release":"2021-01-28T15:50:04","revision":"0","sha1sum":"c491d7499c179880f49d4000c4900f25b5ff7c08","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045665","version":"HPG4.4-7.0.0.15843807"}]}],"id":{"product":"474dacedc05a47e69c05eb6235e4913d","version":"ba114f28fec843b8b356a82b12b2bf2e"},"installation":{"command":"CP040687.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:06:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Blade Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"8243623","datemodified":"2021-03-09T17:58:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560FLB_G33590-000_2.45_800008F0.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560M_G43498-00X_2.18_8000083D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/ofvpdfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/rfendfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045078.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045078.scexe"],"md5sum":"55753286ff1cc2ba87f8059fd4015d6e","name":"firmware-nic-intel-bl-1.2.3-1.1.x86_64.rpm","release":"2021-03-09T17:50:06","revision":"0","sha1sum":"f298bc0185b14c3c82cdf60cd9c09d77c8068de5","size":"7MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3"}],"id":{"product":"efc60b9bf1a141328e5b2c582be6ef7b","version":"8758a32e4f124005a0652bf87381acbb"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP045078.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP045078.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP045078.scexe in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP045078.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n\n<p>&nbsp;</p>\n\n<p>This product now supports the following operatings systems:</p>\n\n<ul>\n\t<li>Red Hat Enterprise Linux 7 Update 7</li>\n\t<li>Red Hat Enterprise Linux 8 Update 0</li>\n\t<li>SUSE Linux Enterprise Server 15 SP1</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an issue where the &quot;Firmware Image Properties,&quot;&nbsp;&quot;Device Level Configuration,&quot;&nbsp;and &quot;Link Speed Status&quot; options in NIC HII menu disappear when F7 is pressed.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800223","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"986372","datemodified":"2021-01-22T05:09:09","file_list":["./opt/emulex/rhel8/x86_64/lib64/libdfc.so","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12.8.316","./opt/emulex/rhel8/x86_64/lib64/libemsdm.so","./opt/emulex/rhel8/x86_64/lib64/libemulexhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/87","./usr/lib/.build-id/87/1f7b2a7900eeec7136801397269cace1613bbc","./usr/lib/.build-id/87/1f7b2a7900eeec7136801397269cace1613bbc.1","./usr/lib/.build-id/be","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955.1","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7.1","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.316","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"58fe7bef48cb40cb53519df028347f2e","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.352.11-1.rhel8.x86_64.rpm","release":"2021-01-22T05:04:41","revision":"0","sha1sum":"99eb2ec13ff712afc0df3288137875925edcc8de","size":"963KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.352.11"}],"id":{"product":"55aaafbf4e5149bd9a06cddaff69d915","version":"070071e7593a45f79bc8ecf111983fa1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"F100","subven":"10DF","target_guid":"a6b1a447-382a-5a4f-10df-f10010dff100","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:51:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.6.272.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.352.11</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGE"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGE"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGE"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGE"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGE"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGE"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n      </strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3119080","datemodified":"2020-12-16T13:59:01","file_list":["cp045567.xml","cpqsetup.exe","M5100MGE.rel","payload.json","setup.dll"],"md5sum":"aea4163e9bcd28571ed9daa35c27e1c2","name":"cp045567.exe","release":"2020-12-16T13:50:04","revision":"0","sha1sum":"7da1990af16377a29f094af31a2975a23b4eaeca","size":"2MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGE"}],"id":{"product":"acb1ff6d668a45ae89fbb3be24e50b7f","version":"b87c6ca7c45a4c10872f04394156c8ae"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:56:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"},{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MK000240GWCEU、MK000480GWCEV、MK000960GWCFA、およびMK001920GWCFBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2798216","datemodified":"2020-12-16T15:38:48","file_list":["cp045560.xml","cpqsetup.exe","GS863aG3.rel","payload.json","setup.dll"],"md5sum":"f4b28ad8d4161c4644b19da562c674bc","name":"cp045560.exe","release":"2020-12-16T15:27:06","revision":"0","sha1sum":"4682c2c12389f457466966af0bb37527b42d894c","size":"2MB","target_guids":["4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"707803ff432e4432b9c2ea604ffe836c","version":"c04d500fdc0040b7bb89d21ca4c1a0bc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:53:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Error Recovery Optimization Enhancements</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"958408","datemodified":"2020-06-03T02:28:03","file_list":["cp042036.xml","cpqsetup.exe","cp_data.xml","install.xml","nicco5.dll","nicdrvr.dll","NicInVXS.dll","vxs64x64.cat","vxs64x64.din","vxs64x64.inf","vxs64x64.sys","vxsmsg.dll"],"md5sum":"3c372659e078bbf8878d2091cac08d95","name":"cp042036.exe","release":"2020-06-03T02:13:04","revision":"0","sha1sum":"e5257d94644df38537d60249e796cb7e0b4930b2","size":"935KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec84549fb3"],"type_of_change":"0","version":"1.2.199.0"}],"id":{"product":"68f339cee17941e6924c89aa13ccc526","version":"9b2351ded5034f2b8c828cc6da56d790"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30116","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30052","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.29.1016"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 10/25GbE 2P SFP28 MCX512F, HPE 10/25GbE 2P SFP28 MCX562A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Windowsオペレーティングシステム上のHPE 10GbE 2P SFP + MCX4121A、HPE 10GbE 2p SFP + MCX4621A OCP3、HPE 10/25GbE 2P SFP28 MCX512F、HPE 10/25GbE 2P SFP28 MCX562A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.29.1016</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (P13188-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (P10112-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.29.1016</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"24486672","datemodified":"2021-01-25T16:34:53","file_list":["cp045143.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_29_1016-MCX4121A-XCH_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX4Lx-rel-14_29_1016-MCX4621A-ACA_Ax-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX5-rel-16_29_1016-MCX512F-ACH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX5-rel-16_29_1016-MCX516A-CCH_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","fw-ConnectX5-rel-16_29_1016-MCX562A-ACA_Ax_Bx-UEFI-14.22.14-FlexBoot-3.6.204.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"8a4095339f5800f51ba3646eb2050eb6","name":"cp045143.exe","release":"2021-01-25T16:33:05","revision":"0","sha1sum":"2aeb14cccb9b45b3bbf3f497bf701053dada72ed","size":"23MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30116","a6b1a447-382a-5a4f-15B3-101715B30052","a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.0.4"}],"id":{"product":"a8ea930bfde1449ab4444eb61f65be31","version":"9e32b7debcb24a8a9625efaf2d6cb1ce"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n [インストール]ボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-08T08:56:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.27.4000:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.27.2008:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>New Feature and Changes in Version 12.27.4000:</strong></p>\n\n<ul>\n\t<li>Added the following segments, as appeared in the PRM, to the Resource Dump:\n\t<ul>\n\t\t<li>PRM_QUERY_QP</li>\n\t\t<li>PRM_QUERY_CQ</li>\n\t\t<li>PRM_QUERY_MKEY</li>\n\t\t<li>QUERY_VNIC_ENV</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.27.2008:</strong></p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<ul>\n\t<li>Improved init_hca performance in Parallel Function initialization.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 16.27.2008:</strong></p>\n\n<ul>\n\t<li>Although the effective BER (after FEC) was expected to meet the design&nbsp;targets (e.g. 10e-14 or lower), occasionally it was higher.</li>\n\t<li>High BER occured when connecting cables of type 0.5/1m DAC to an&nbsp;HDR speed.</li>\n\t<li>The PCIe Tx parameters did not load correctly when the speed was changed after the PCIe link was disabled.</li>\n\t<li>The desched_threshold field did not work properly.</li>\n\t<li>The &quot;roce_adp_retrans&quot; counter was presenting the&nbsp;values of the &quot;local_ack_timeout_err&quot; counter.</li>\n\t<li>If Relaxed Ordering was&nbsp;disabled by running the &quot;setpci&quot; command, it would not be functional even after re-enabling it by running the &quot;setpci&quot; command again.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 14.27.4000:</strong></p>\n\n<ul>\n\t<li>The device hung while running the sw reset flow under heavy stress and with many open resources.</li>\n\t<li>Low PXE performance observerd while using the VSC to trigger the&nbsp;send_ring_doorbells.</li>\n\t<li>IPoIB and DC would not work together.</li>\n\t<li>DC funtionality issues.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.29.1016:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)<br />\nP11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.29.1016:</strong></p>\n\n<p>P13188-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter)<br />\nP21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)<br />\nP10112-B21 (HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter)</p>\n\n<p><strong>This release contains important reliability improvements and security hardening&nbsp;enhancements. Upgrade the&nbsp;firmware of the device to this release to improve the devices&rsquo; firmware&nbsp;security and reliability.</strong></p>\n\n<p><strong>New Feature and Changes in Version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Ethernet wqe_too_small Mode: A per vPort that counts the number of packets that reached the Ethernet RQ but cannot fit into the WQE due to their large size. Additionally, we added the option to control if such packet will cause &ldquo;CQE with Error&rdquo; or &ldquo;CQE_MOCK&rdquo;.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>cq_overrun counter: The counter represents the number of times CQs enter an error state due to overflow that occur when the device tries to post a CQE into a full CQ buffer.</li>\n\t<li>Enabled the capability to allow Virtual Functions to send Pause Frames packets. (Beta)</li>\n\t<li>Enabled 10/25GbE auto-sensing with 3rd party when using 10/25GbE optical cables.</li>\n</ul>\n\n<p><strong>New Feature and Changes in Version 16.29.1016:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p style=\"margin-left:40px\">Added support for the following features:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HW support for Flow Metering to utilize Advanced Steering Operation (ASO).&nbsp;HW Flow Meter allows higher scale, more accuracy, and better performance compare to the FW Flow Metering.</li>\n\t<li>Trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>2 new Mini CQE formats:</li>\n\t<li>Responder Mini CQE With Flow Tag Layout.</li>\n\t<li>Responder Mini CQE With l3_l4_info Layout.</li>\n\t<li>Steering DP hash flow groups.</li>\n\t<li>ignore_flow_level is now enabled by the TRUST LEVEL access registry.&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 14.29.1016 and 16.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that caused packets to drop due to header size issues and/or failing checks. This issue was caused due to a Linux issue that caused VFs to set the wrong header size value in wqe_inline_header_mode input.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) might take longer than when MKEY_BY_NAME was disabled.</li>\n\t<li>In rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n\t<li>An issue that caused the device to go to dead IRISC as one of the firmware semaphores could not be released when a speed change or port state change was triggered.</li>\n</ul>\n\n<p><strong>Following issues have been fixed in firmware version 16.29.1016:</strong></p>\n\n<ul>\n\t<li>An issue that caused the eth_wqe_too_small counter to count ODP page faults.</li>\n\t<li>A low performance was observed after enabling the RoCE Accelerator capability.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5408530","datemodified":"2021-01-26T18:21:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/CP046385.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046385.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046385.scexe"],"md5sum":"f394898b0fa6c3a21e79e93075f7dcde","name":"firmware-smartarray-7b5e8400dd-1.27-1.1.x86_64.rpm","release":"2021-01-26T18:03:04","revision":"0","sha1sum":"87a41837b71553028ff4ae1ef08ded11ba69bfb4","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"id":{"product":"b94490ecb4854ca6989ed2491e061c4b","version":"24d2af3292a346209305cb8ad90a068a"},"installation":{"command":"CP046385.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP046385.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP046385.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-03T13:04:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000300JWBHR"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG000300JWBHR Drive<br />\n </p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>      </strong>HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"3017800","datemodified":"2020-12-17T14:06:29","file_list":["cp045490.xml","cpqsetup.exe","payload.json","setup.dll","T14SEnD4.REL"],"md5sum":"444b850437ede5ab14bf5abb58c72fe5","name":"cp045490.exe","release":"2020-12-17T13:58:08","revision":"0","sha1sum":"6852a3cc2608b03e001d3db237bd3df6ab8ac96a","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"a893ea1028be45a18d3b23d1c1c00c64","version":"d416ad114af947d7831757c035a99fb3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWBHR Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:28:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4499426","datemodified":"2021-01-09T01:09:30","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-i40e","./lib/modules/5.3.18-22-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"c6c28e0ec5b09f0ec7da29f7b798bec3","name":"hp-i40e-kmp-default-2.13.10_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-09T00:59:10","revision":"0","sha1sum":"ee90aeabc7633a78e2484402b7583624977fec93","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.13.10-1"},{"bytes":"3885029","datemodified":"2021-01-09T01:07:04","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-i40e","./lib/modules/4.12.14-195-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"47ddcf23a8bc51f6c25c0c3d18824407","name":"hp-i40e-kmp-default-2.13.10_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-09T00:59:10","revision":"0","sha1sum":"0c088d2bf5b4ce4bf95ce7a27729febfed3d5998","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"0","version":"2.13.10-1"}],"id":{"product":"7204c0f5c514445a87ae5a6c742f6a37","version":"199c1380a23348df92e3b8a180a4a234"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</li>\n\t<li>This product corrects an issue which querying DCB configuration data failed on Intel Carslville controller if driver probe or set &nbsp;at 2.5/5G speed.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product supports new feature called software DCB(Data Center Bridging) which allows using DCB without firmware LLDP(Link Layer Discovery Protocol) agent being turned on.</li>\n\t<li>This product supports new feature which allows user to specify VLAN(Virtual Local Area Network) field and add it to flow director via ethtool</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where server hungs after loading XDP(eXpress Data Path) program in case of LLDP(Link Layer Discovery Protocol) agent disabled&nbsp;</li>\n\t<li>This product addresses an issue where it is not possible to change MAC(Media Access Control) address on VF(Virtual Function) from VM(Virtual Machine) when VF is in trusted mode</li>\n\t<li>This product addresses an issue where it cannot create VF(Virtual Function) VLAN(Virtual Local Area Network) interface inside a namespace&nbsp;</li>\n\t<li>This product addresses an issue where system crash during removing driver when VSI(VIrtual Station Interface) is in reset recovery mode</li>\n\t<li>This product addresses an issue where VF(Virtual Function) receives unicast packets from other VF</li>\n\t<li>This product addresses an issue where using Intel nvmupdate utility never ending update</li>\n\t<li>Thips product addresses an issue where kernel crash in vf driver(iavf) reset when pf driver(i40e) is removing</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb15900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"218.0.166000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.166000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"218.0.166000"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 218.0.166000 with the following firmware versions:</p>\n\n<ul>\n\t<li>Bootcode Version: 218.0.152.0</li>\n\t<li>NCSI Version: 218.0.125.0</li>\n\t<li>MBA Version:&nbsp;218.0.29.0</li>\n\t<li>UEFI Version:&nbsp;218.0.64.0</li>\n\t<li>CCM Version:&nbsp;218.0.19.0</li>\n\t<li>RoCE Version:&nbsp;218.0.5.0</li>\n</ul>\n"}],"files":[{"bytes":"8060474","datemodified":"2021-02-09T07:29:38","file_list":["bcm218.0.166000.Optimized.pup.HPb","bcm218.0.166000.Optimized.pup.xml","payload.json"],"md5sum":"c5136fcb6f46a0208bf5a5378681f077","name":"bcm218.0.166000.Optimized.pup.fwpkg","release":"2021-02-09T07:25:10","revision":"0","sha1sum":"0134d3a6b5ee6ae15d1af68dc8e0124caaa959a9","size":"7MB","target_guids":["a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16eb15900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16d815900212"],"type_of_change":"1","version":"218.0.166000"}],"id":{"product":"8d2bd99747b540d2a364efef8e58a91c","version":"523b8eb282404350b8cb2426c220088c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses a modification on help string of Family Firmware Version.</li>\n\t<li>This product addresses an enhancement on LLDP functional option naming under RBSU and the interactivity of DCB protocol option.</li>\n\t<li>This product addresses an issue about lack of MAC address while querying via RedFish.</li>\n\t<li>This product addresses an issue about failing to recognize the adapter firmware version under Microsoft Windows(R).</li>\n\t<li>This product addresses an issue for receiving PCIe errors while installing SUSE Linux Enterprise Server.</li>\n\t<li>This product addresses an issue for packets missing when UDP multicast application is started/stopped.</li>\n\t<li>This product addresses an issue for HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter not linking up during POST.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"NIC_NXE_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 8 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"97391","datemodified":"2020-12-09T05:21:14","file_list":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/megaraid_sas","./lib/modules/4.18.0-193.el8.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/58","./usr/lib/.build-id/58/2a0e491587075ef621ae092bfb7baea8c20b1a","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"2a2cf471de8264c57035e7596337349f","name":"kmod-megaraid_sas-07.716.02.00_el8.2-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"c608ffa9efeb1349d270d720ae6ae2bbc8240dbd","size":"95KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"97389","datemodified":"2020-12-09T05:24:21","file_list":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/megaraid_sas","./lib/modules/4.18.0-240.el8.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/6b4e12bddc853a03b81a7d11da8a98772d0ff3","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"e87fcf768970a0f4a08470817f91a920","name":"kmod-megaraid_sas-07.716.02.00_el8.3-1.x86_64.rpm","release":"2021-03-22T00:00:00","revision":"2","sha1sum":"6c3ae339da0aa96cd1fa34b628da16b8f82336d2","size":"95KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"d8869737bfef407fbb159aff392990e1","version":"508d96363da141d680c0c40ce3402ecc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-29T13:12:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication. "},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティーが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"10871861","datemodified":"2021-03-18T21:34:44","file_list":["/cp047035.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/index.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/vendor-index.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/hponcfg-6.0.0.5.5-0.37.2494585.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/bootcfg-6.0.0.02-06.00.16.2494585.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/conrep_650.10.7.0.1-6.5.0.2494585.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/ilo_650.10.7.0.4-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/testevent-6.5.0.02-01.00.9.4240417.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/MIS_bootbank_hpessacli-5.10.45.1-6.5.0.4240417.oem.vib","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vendor-index.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vmware.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/hponcfg-1881737420209856034.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/bootcfg-1749855250648854147.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/cru-6087260586819000143.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/conrep--1459825434788523466.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/hpessacli-1806097827822448831.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/testevent--766157199079035683.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/vibs/ilo--424181866709235809.xml","/HPE-Utility-Component_6.5.0.10.7.1-8.zip/metadata-HPE-Utility-Component_6.5.0.10.7.1-8.zip/bulletins/esxi6.5-util-bundle-10.7.1-8.xml"],"md5sum":"0406fd1be5792765583ca24f810f1ac5","name":"cp047035.zip","release":"2021-03-18T21:32:04","revision":"0","sha1sum":"3a4658fc77da6d137979b904586945564397907c","size":"10MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9"],"type_of_change":"1","version":"2021.04.02","vib_list":[{"name":"hponcfg","version":"6.0.0.5.5-0.37.2494585"},{"name":"bootcfg","version":"6.0.0.02-06.00.16.2494585"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"},{"name":"conrep","version":"650.10.7.0.1-6.5.0.2494585"},{"name":"hpessacli","version":"5.10.45.1-6.5.0.4240417.oem"},{"name":"testevent","version":"6.5.0.02-01.00.9.4240417"},{"name":"ilo","version":"650.10.7.0.4-1OEM.650.0.0.4240417"}]}],"id":{"product":"161a304825cb434e83dc121e59667140","version":"39c33a1b6177441dab7920f0232b6bdd"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&amp;lang=en&amp;cc=us\">HP USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"http://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=8788688&lang=en&cc=us\">HP USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Managerの手順に従って、アップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.5 "},{"lang":"ja","x_late":"HPE ユーティリティ バンドルSmartコンポーネント for ESXi 6.5 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-08T01:26:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Includes an updated the Smart Storage Administrator CLI&nbsp;(SSACLI).</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Pickup latest SIGNED hpssacli.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpessacli:5.10.45.1-6.5.0.4240417.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"testevent:6.5.0.02-01.00.9.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:650.10.7.0.1-6.5.0.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"hponcfg:6.0.0.5.5-0.37.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:650.10.7.0.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.0.0.02-06.00.16.2494585","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGE"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGE"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGE"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGE"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGE"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGE"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGE"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGE.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGE"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK, and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16368814","datemodified":"2021-01-28T12:06:50","file_list":["/CP045694_BUILD_4.data","/CP045694.vmexe","/CP045694.vmexe64","/CP045694.vmfile","/CP045694_VMw.zip","/CP045694.xml","/payload.json","/CP045694_VMw.zip/index.xml","/CP045694_VMw.zip/vendor-index.xml","/CP045694_VMw.zip/metadata.zip","/CP045694_VMw.zip/vib20/CP045694/HPE_bootbank_CP045694_HPGE.4-7.0.0.15843807.vib","/CP045694_VMw.zip/metadata.zip/vendor-index.xml","/CP045694_VMw.zip/metadata.zip/vmware.xml","/CP045694_VMw.zip/metadata.zip/vibs/CP045694--3320695078835153148.xml","/CP045694_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045694_HPGE.4-7.0.0.15843807.xml"],"md5sum":"1f3d098d809847a322c05e973cc81815","name":"CP045694.zip","release":"2021-01-28T12:04:05","revision":"0","sha1sum":"0dc216bb892db0ef008ae47b4af42dc1c2f1ba34","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"0","version":"HPGE","vib_list":[{"name":"CP045694","version":"HPGE.4-7.0.0.15843807"}]}],"id":{"product":"3a33d0d2b6ca440681703cda5e638a33","version":"dcfa3d0fa65042e5b08b49755a129c57"},"installation":{"command":"CP041318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:29:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19698360","datemodified":"2021-01-24T09:41:24","file_list":["cp044872.xml","cpqsetup.exe","fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"02adb5ea65df38d2f62778f7264f7d4a","name":"cp044872.exe","release":"2021-01-24T09:40:04","revision":"0","sha1sum":"f24c237f4da3510d3d51f134219fba5bc4f68544","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.0.3"}],"id":{"product":"25bee0f636714c0e8bface2301234fec","version":"504a9c7f1e354acab91ba4e7f72387fd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T11:59:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.27.6008:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when&nbsp;connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>ConnectX-6: 20.27.2008*<br />\n\t\t*Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link&nbsp;speeds.</li>\n\t</ul>\n\t</li>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>Enabled KP4RS FEC on Active Fiber cable up to 30m.</li>\n\t\t<li>FDR protocol.</li>\n\t\t<li>Enabled updating End-to-End (E2E) credit packets instantly.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>There are no new fixes in firmware version 20.27.6008.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.29.1016:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n</ol>\n\n<ol start=\"7\">\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n\n<ul>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55081","datemodified":"2021-01-19T03:12:24","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"0cf510c6030263e52ff037331af8a9e7","name":"kmod-hp-ixgbevf-4.9.3-1.rhel8u2.x86_64.rpm","release":"2021-01-19T03:00:05","revision":"0","sha1sum":"89e2ceafb185936ee086408fc31a20380269d6b2","size":"53KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"55132","datemodified":"2021-01-19T03:10:26","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"b6f96ed78fcdbbd1febe845045fbb022","name":"kmod-hp-ixgbevf-4.9.3-1.rhel8u3.x86_64.rpm","release":"2021-01-19T03:00:05","revision":"0","sha1sum":"2546479b1a6a0701e71a5944e67aec17bc6be255","size":"53KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"30f1903e29c9444e8763652af6b41477","version":"7daec0f74d024ffc917804c41ba8db47"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product update Linux kernel documentation and Configure IRQ affinity tools</p>\n","latest_fixes_x_late":"<p>This product corrects an issue which errata kernel loads inbox driver instead of this component after booting into OS</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"22086","datemodified":"2021-01-28T18:11:04","file_list":["/cp045983.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/index.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/vendor-index.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/metadata.zip","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/vib20/ilo/HPE_bootbank_ilo_700.10.7.0.6-1OEM.700.1.0.15843807.vib","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/metadata.zip/vendor-index.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/metadata.zip/vmware.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/metadata.zip/vibs/ilo--5650754520179440249.xml","/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807_17481969.zip/metadata.zip/bulletins/ilo-driver_700.10.7.0.6-1OEM.700.1.0.15843807.xml"],"md5sum":"dfce33d1f54b6335a1f7bc33eb249601","name":"cp045983.zip","release":"2021-01-28T18:10:04","revision":"0","sha1sum":"e4e9815a6cfa082f98fe90dba5188cc6c00a7a9e","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"ilo","version":"700.10.7.0.6-1OEM.700.1.0.15843807"}]}],"id":{"product":"6439c3485f63410da139047f5f5bc562","version":"cc43930523c74752b1e37147bbf2243e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE iLO Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-10T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Supports VMware ESXi 7.0 U1 and ESXi 7.0 U2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ilo:700.10.7.0.6-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"ilo-driver:700.10.7.0.6-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2902931","datemodified":"2021-03-22T15:35:31","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"2cd7de5ea08c91453920603bf24783b5","name":"amsd-2.4.1-1571.4.rhel7.x86_64.rpm","release":"2021-03-22T15:26:13","revision":"0","sha1sum":"007dfa4c8fcd3f896210150ef85c3f4576d2608e","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"2","version":"2.4.1"}],"id":{"product":"f9f0f575f0ee448d89b3c55f9e30c251","version":"060a997cbeb24642af4c2668607fd1a8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-04T16:32:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed the following item:</p>\n\n<ul>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp; Customers experiencing this issue are requested to update to amsd version 2.3.1.&nbsp;&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This release contains the following enhancements:</p>\n\n<ul>\n\t<li>Enhance the robust communication with iLO. The enhancement has a proper process exist and OS signal handling.</li>\n\t<li>Enhance the SMA logging system for better recording of the communication events.</li>\n\t<li>The AMSD reports the Open NIC controllers SN to align with iLO for avoiding the un-sync information.</li>\n</ul>\n","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>Addressed a small amount of memory leak as outlined in the Customer Advisory,&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00053824en_us\">a00053824en_us</a></li>\n\t<li>A customer may experience where smad may periodically report: No response from iLO for Hello.&nbsp; After losing connection with iLO, the subagent may experience&nbsp;high CPU utilization for trying the reconnection. This issue is documented in Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111063en_us</a>.&nbsp;</li>\n\t<li>The cpqIde service not able to start while the AMSD configuration is agent mode.</li>\n\t<li>Addressed&nbsp;buffer overflow issues in select&nbsp;corner cases.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2016用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"907296","datemodified":"2020-06-12T06:47:06","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044561.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"d7398cbac6a655eb182f2b86ba3d8494","name":"cp044561.exe","release":"2020-06-12T06:33:15","revision":"0","sha1sum":"93c0e7dbdda6b4f84f1fca21bb803d28b49d12df","size":"886KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"70f19ffffee546149605e6df93bd9de3","version":"0ce26dd3cd4744ca9f29d5a742fa7ceb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; Added support for Windows Server 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4446880","datemodified":"2020-12-11T18:39:56","file_list":["cp045901.xml","cpqsetup.exe","GSM883G3.rel","payload.json","setup.dll"],"md5sum":"568cf777815eba49da81942596e905f1","name":"cp045901.exe","release":"2020-12-11T18:29:05","revision":"0","sha1sum":"32b1877f6121108b212d2c3d90e989d38ba4c3c0","size":"4MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"2a24f9ce00084650b7c1f83427a4e25f","version":"a02261c5a06247f6856decd2852f7b4c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T12:37:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>PrefetchClear logic error on Write CMD.</li>\n\t<li>ICRC Data Integrity improvement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE 81E 8Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3281","Version":"1280A3"},{"DeviceName":"HPE 82E 8Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C3282","Version":"1280A3"},{"DeviceName":"HPE SN1000E 16Gb 1-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E4","Version":"12.8.352.12"},{"DeviceName":"HPE SN1000E 16Gb 2-port PCIe Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C17E5","Version":"12.8.352.12"},{"DeviceName":"HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197F","Version":"12.8.352.12"},{"DeviceName":"HPE  SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C197E","Version":"12.8.352.12"},{"DeviceName":"HPE 84E 4-port 8Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//boot//UU1280A3.PRG","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F100103C2238","Version":"1280A3"},{"DeviceName":"HPE SN1100E 4-port 16Gb Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200159000FB","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.352.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.352.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.352.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12835212.grp","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.352.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900215","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"18174763","datemodified":"2021-01-29T06:33:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/CP044731.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/boot","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/boot/UU1280A3.PRG","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/elxflashStandalone-linux-12.8.352.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/firmware/A12835212.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/firmware/B12835212.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/firmware/P12835212.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/firmware/UD210X6.ALL","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2021.02.01-1.23/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP044731.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP044731.scexe"],"md5sum":"677faf01b36ed4ed5c7e88032913d38b","name":"firmware-fc-emulex-2021.02.01-1.23.x86_64.rpm","release":"2021-01-29T06:20:06","revision":"0","sha1sum":"674b615209fe7eb87a8a4826cfeadb38dc5e0f5e","size":"17MB","target_guids":["a6b1a447-382a-5a4f-10DF-F100103C3281","a6b1a447-382a-5a4f-10DF-F100103C3282","a6b1a447-382a-5a4f-10DF-E200103C17E4","a6b1a447-382a-5a4f-10DF-E200103C17E5","a6b1a447-382a-5a4f-10DF-E200103C197F","a6b1a447-382a-5a4f-10DF-E200103C197E","a6b1a447-382a-5a4f-10DF-F100103C2238","a6b1a447-382a-5a4f-10DF-E200159000FB","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D6","a6b1a447-382a-5a4f-10DF-F400159002D5"],"type_of_change":"1","version":"2021.02.01"}],"id":{"product":"ccd2fccdbff94b0ab75d085d46522784","version":"26463067cde141168363c49d5447a0c1"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"},{"lang":"ja","x_late":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br />\n <br />\n 1. ファームウェアインストレーションツール：rpm -Uhv <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64-bitシステム）。<br />\n <br />\n 2. 使用するシステムの適切な場所へcd し、./.setupを実行してファームウェアをアップデートします<br />\n <br />\n ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F100","subdev":"3281","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3281","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"3282","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c3282","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e4","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"17E5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c17e5","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197f","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"197E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c197e","type":"pci","ven":"10DF"},{"dev":"F100","subdev":"2238","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-f100103c2238","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"00FB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e200159000fb","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T11:50:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp; have separate components to update fibre channel and converged network adapters.&nbsp;This is a fibre channel&nbsp;update component.</p>\n\n<p><strong>Contains:</strong></p>\n\n<p>&nbsp;</p>\n\n<p>32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16/32 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>16 Gb universal boot 12.6.275.12(EFI 12.6.275.7 BOOT BIOS 12.6.271.0 Firmware 12.6.275.12)</p>\n\n<p>8 Gb HBA Standup firmware 2.10X6<br />\n8 Gb standup universal boot image 12.60a4(12.6.302.0 BIOS, 12.6.284.0 UEFI)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 81E 8Gb Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 82E 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE 84E 8Gb Quad Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">8Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.80a3</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">2.10X6</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.183.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.9.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1000E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100E Quad Port 16Gb Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:top\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16474508","datemodified":"2021-01-28T19:22:06","file_list":["/CP046318_BUILD_3.data","/CP046318.vmexe","/CP046318.vmexe64","/CP046318.vmfile","/CP046318_VMw.zip","/CP046318.xml","/payload.json","/CP046318_VMw.zip/index.xml","/CP046318_VMw.zip/vendor-index.xml","/CP046318_VMw.zip/metadata.zip","/CP046318_VMw.zip/vib20/CP046318/HPE_bootbank_CP046318_HPD4.3-7.0.0.15843807.vib","/CP046318_VMw.zip/metadata.zip/vendor-index.xml","/CP046318_VMw.zip/metadata.zip/vmware.xml","/CP046318_VMw.zip/metadata.zip/vibs/CP046318--6476620441256413095.xml","/CP046318_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046318_HPD4.3-7.0.0.15843807.xml"],"md5sum":"57b7b15252bf1e08beaeb24ee26ee56c","name":"CP046318.zip","release":"2021-01-28T19:19:04","revision":"0","sha1sum":"81a2d445fc15521a7a5fd8254d711b6a06799896","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP046318","version":"HPD4.3-7.0.0.15843807"}]}],"id":{"product":"0b3bbfed90454334ba3331c2f9efa2ea","version":"c7013c08f08a4e3995b6ce9f08a8cc44"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-23T18:18:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Increased Queue Size from 32 to 128 to be equal to the max number of chips.</li>\n\t<li>Refresh NM SRAM area periodically only when idle as a possible work around on NM SRAM parity error.</li>\n\t<li>Change the error response as 0x3 (SP_Busy) or 0x07 ( NO_SESSION_AVAILABLE) when host attempts to open another session while a session is already opened.</li>\n\t<li>Disable verify compare if APP_CHK=0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 (64-bit) to enable the HPE Smart Array B140i SATA RAID controller."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array B140i SATA RAIDコントローラーを有効にする、Red Hat Enterprise Linux 7（64-bi）用のビルド済みバイナリドライバーモジュールを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"912627","datemodified":"2020-10-01T12:01:23","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpdsa","./lib/modules/3.10.0-1127.el7.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"4b31e33aa3d0cc40cb1bb6226e3ec4c5","name":"kmod-hpdsa-1.2.10-184.rhel7u8.x86_64.rpm","release":"2020-10-01T11:47:05","revision":"0","sha1sum":"c1f72d0bbc85a1eb7cddff690e8926686999010c","size":"891KB","target_guids":[],"type_of_change":"1","version":"1.2.10-184"},{"bytes":"912629","datemodified":"2020-10-01T11:55:15","file_list":["./etc/depmod.d/hpdsa.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpdsa","./lib/modules/3.10.0-1160.el7.x86_64/extra/hpdsa/hpdsa.ko","./usr/share/smartupdate/kmod-hpdsa/component.xml"],"md5sum":"9fa812b5f309d97df3886dd23f7c76b3","name":"kmod-hpdsa-1.2.10-184.rhel7u9.x86_64.rpm","release":"2020-10-01T11:47:05","revision":"0","sha1sum":"4cd0b696f2801fd6fd52893888563608f70e3f07","size":"891KB","target_guids":[],"type_of_change":"1","version":"1.2.10-184"}],"id":{"product":"45de3d94e74d43a1ad4f5b8b01de0092","version":"80676a7ea3f24dfe983233cfea632a09"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p dir=\"ltr\"><strong>To install&nbsp;or&nbsp;upgrade&nbsp;the driver type:</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">NOTE: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p dir=\"ltr\">&nbsp;</p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit&nbsp;<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p dir=\"ltr\"><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<p># rpm -Uvh kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p>Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p dir=\"ltr\">注：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<p dir=\"ltr\"># rpm -e kmod-hpdsa-<version>.<OSupdate>.x86_64.rpm</p>\n\n<p dir=\"ltr\"> </p>\n\n<p dir=\"ltr\"><strong><u>Enterprise Support</u></strong><br />\nエンタープライズサポートSmartアレイコントローラーのサポートに関しては <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Dynamic Smart Array B140i SATA RAID Controller Driver for Red Hat Enterprise Linux 7 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7（64-bit）用HPE Dynamic SmartアレイB140i SATA RAIDコントローラードライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-08T15:52:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 8</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add support for Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U25","value":"HP ProLiant XL280d Accelerator Tray - cancelled"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpdsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06154-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06250-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.29.1016"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_29_1016-P06251-B21_Ax-UEFI-14.22.14-FlexBoot-3.6.204.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.29.1016"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (P06154-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (P06250-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (P06251-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"26847908","datemodified":"2021-02-03T04:10:03","file_list":["/CP044869.vmexe","/CP044869.vmfile","/CP044869_VMw.zip","/CP044869.xml","/payload.json","/README.txt","/CP044869_VMw.zip/index.xml","/CP044869_VMw.zip/vendor-index.xml","/CP044869_VMw.zip/metadata.zip","/CP044869_VMw.zip/vib20/CP044869/HPE_bootbank_CP044869_1.0.1-6.5.0.4240417.vib","/CP044869_VMw.zip/metadata.zip/vendor-index.xml","/CP044869_VMw.zip/metadata.zip/vmware.xml","/CP044869_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044869_1.0.1-6.5.0.4240417.xml","/CP044869_VMw.zip/metadata.zip/vibs/CP044869-153460443900433663.xml"],"md5sum":"038e08e62a1a5db2269188d8d2215203","name":"CP044869.zip","release":"2021-02-03T04:14:04","revision":"0","sha1sum":"322076a699db1a4a4718351bbc16f4966b2ce0b3","size":"25MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP044869","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"08ec266b2d2d49f5bd28c75479361f16","version":"8bc8caf473734efca692527d8ac54b6e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-14T11:59:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.27.6008:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.27.6008:</strong></p>\n\n<ul>\n\t<li>The following are the minimal software/firmware versions that support PAM4 link speeds when&nbsp;connected using Mellanox NIC to Mellanox Switch and Mellanox NIC to 3rd Party Switches:\n\t<ul>\n\t\t<li>Mellanox Onyx: 3.9.0830-038</li>\n\t\t<li>ConnectX-6: 20.27.2008*<br />\n\t\t*Note: NICs with this firmware version support Mellanox-to-Mellanox connectivity with PAM4 link&nbsp;speeds.</li>\n\t</ul>\n\t</li>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>Enabled KP4RS FEC on Active Fiber cable up to 30m.</li>\n\t\t<li>FDR protocol.</li>\n\t\t<li>Enabled updating End-to-End (E2E) credit packets instantly.</li>\n\t</ul>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>There are no new fixes in firmware version 20.27.6008.</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.29.1016:</strong></p>\n\n<p>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21<br />\n&nbsp;</p>\n\n<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ul>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD5"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Added support for RHEL 8.3</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5994698","datemodified":"2020-12-13T12:49:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/CP045418.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/HLIBRHsseFD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045418.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045418.scexe"],"md5sum":"85b863a7b6e5de510d81616c01eed084","name":"firmware-hdd-6ec35faf90-HPD5-6.1.x86_64.rpm","release":"2020-12-13T12:34:08","revision":"0","sha1sum":"83ea5e016cdad711deb1aeeca4eefc8b46817ba6","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"2","version":"HPD5"}],"id":{"product":"21c2460d0eda43ee8d9561eb3baf6bcd","version":"1a0991d8a5624f7d9ebc33a33dcc65aa"},"installation":{"command":"CP040326.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:15:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.  </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2257180","datemodified":"2020-12-02T11:14:41","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"7539d051d2e79e3238d437912b503112","name":"mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel7u9.x86_64.rpm","release":"2020-12-02T09:36:05","revision":"0","sha1sum":"4142517c57075248e191da36958bf975ebc7ace7","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9"},{"bytes":"1709686","datemodified":"2020-12-02T11:18:29","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i915.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-kvmgt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vfio_mdev.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/i915.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/kvmgt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/mdev.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/mdev/vfio_mdev.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"36e10c217d74e11a8507909ae17b2f2d","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel7u9.x86_64.rpm","release":"2020-12-02T09:36:05","revision":"0","sha1sum":"a3a3230bbe985e487d051cdffb63da7f32c13dbd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9"}],"id":{"product":"408f4a25d4b44e79916ac17904fc2648","version":"be8dc6678c024860b819cd47cd51bd6a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.rhel7u9.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.2.2.4.1.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-02T08:42:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>An issue where injecting EEH (Extended Error Handlng) may cause extra Kernel prints, such as: &ldquo;EEH: Might be infinite loop in mlx5_core driver&rdquo; was fixed.</li>\n\t<li>RPM-based OSs with non-default kernels, using repositories after re-creating the installer (using --add-kernel-support) were&nbsp;resulting&nbsp;in improper installation of the drivers.</li>\n\t<li>A typo in perftest package where help messages wrongly displayed the conversion result between Gb/s and MB/s (20^2 instead of 2^20).</li>\n\t<li>When one of the LAG slaves went down, LAG deactivation failed, ultimately causing bandwidth degradation.</li>\n\t<li>The mlx5 driver maintains a subdirectory for every open eth port in /sys/kernel/debug/. For the default network namespace, the sub-directory name is the name of the interface, like &quot;eth8&quot;. The new convention for the network interfaces moved to the non-default network namespaces is the interfaces name followed by &quot;@&quot; and the port&#39;s PCI ID. For example: &quot;eth8@0000:af:00.3&quot;.</li>\n\t<li>&quot;openibd&quot; script load used to fail when esp6_offload module did not load successfully.</li>\n\t<li>Added dependency of package mpi-selectors on perl-Getopt-Long system package. On minimal installs of RPM-based OSs, installing mpi-selectros will also install the required system package perl-Getopt-Long.</li>\n\t<li>During certain rare scenarios, due to Rx page not being replenished, the same page fragment mistakenly became assigned to two different Rx descriptors.</li>\n\t<li>Driver load issue existed with Errata-kernel on SLES15 SP1.</li>\n\t<li>An issue in the Hairpin feature which prevented adding hairpin flows using TC tool was fixed.</li>\n\t<li>WQ (Work Queue)&nbsp;queue flushing was not handled properly in the event of EEH.</li>\n\t<li>A rare kernel crash scenario when exiting an application that uses RMPP mads intensively.</li>\n\t<li>A possible kernel crash scenario when AER/slot reset in done in parallel to user space commands execution.</li>\n\t<li>Added missing ECN (Explicit Congestion Notification) configuration under sysfs for PFs in SwitchDev mode.</li>\n\t<li>When firmware response time to commands became very long, some commands failed upon timeout. The driver may have then triggered a timeout completion on the wrong entry, leading to a NULL pointer call trace.</li>\n\t<li>Added driver support for kernels with the old XDP_REDIRECT infrastructure that uses the following NetDev operations: .ndo_xdp_flush and .ndo_xdp_xmit.</li>\n\t<li>Usage of --excludedocs Open MPI RPM option resulted in the removal of non-documentation related files.</li>\n\t<li>Disabled automated loading of some modules through udev triggers to preserve the startup process of previous MLNX_OFED versions.</li>\n\t<li>Reference count (refcount) for RDMA connection ID (cm_id) was not incremented in rdma_resolve_addr() function, resulting in a cm_id use-after-free access. A fix was applied to increment the cm_id refcount</li>\n\t<li>A race condition which caused kernel panic when moving two ports to SwitchDev mode at the same time.</li>\n\t<li>Allowed accessing sysfs hardware counters in SwitchDev mode</li>\n\t<li>Function smp_processor_id() is called in the RX page recycle flow to determine the core to run on. This is intended to run in NAPI context. However, due to a bug in backporting, the RX page recycle was mistakenly called also in the RQ close flow when not needed.</li>\n\t<li>Port link state was automatically changed (without admin state involvement) to &quot;UP&quot; after reboot.</li>\n\t<li>ConnectX-3 adapter cards froze when running over SLES 11 OS.</li>\n\t<li>RDMA CM (Remote Direct Memory Access Communation Manager) connection failed when port space was small.</li>\n\t<li>Traffic mirroring with OVS (Open VSwitch)offload and non-offload over VxLAN interface is now supported. Note: For kernel 4.9, make sure to use a dedicated OVS version.</li>\n\t<li>When working with VF LAG while the bond device is in active-active mode, running fwreset would result in unequal traffic on both PFs, and PFs would not reach line rate.</li>\n\t<li>When bond was created over VF (Virtuaal Function)&nbsp;netdevices in SwitchDev mode, the VF netdevice would be treated as representor netdevice. This caused the mlx5_core driver to crash in case it received netdevice events related to bond device.</li>\n\t<li>An issue where following a bad affinity occurrence in VF LAG mode, traffic was sent after the port went up/down in the switch.</li>\n\t<li>Added support for VLAN (Virtual Local Area Network)&nbsp;header rewrite on CentOS 7.2 OS.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Windows Server 2016. 的 HPE Mellanox CX3 Ethernet NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX3 Ethernet NICs for Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Windows Server 2016용 HPE Mellanox CX3 이더넷 NIC에 사용할 수 있는 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"该组件包内含面向Windows Server 2016的HPE Mellanox CX3以太网网卡驱动程序。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX3 Ethernet NIC for Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"18458896","datemodified":"2019-10-08T04:23:44","file_list":["cp040866.xml","cpqsetup.exe","cp_data.xml","ibbus.sys","install.xml","ipoib6x.cat","ipoib6x.inf","ipoib6x.sys","MLNX_VPI_WinOF-5_35_HP_win2016_x64.exe","mlx4eth63.cat","mlx4eth63.inf","mlx4eth63.sys","mlx4_bus.cat","mlx4_bus.inf","mlx4_bus.sys","mlx_setup.dll","ndfltr.sys","nicdrvr.dll","RestartDriver.exe","Tenable-Upgrade.ps1","winctxtune_bus.dll","winctxtune_eth.dll","winctxtune_ipoib.dll","winmad.sys","winverbs.sys"],"md5sum":"b220f0690db3002afa6b4474d1086ea9","name":"cp040866.exe","release":"2019-10-08T04:08:02","revision":"0","sha1sum":"75a861b9027084526b5b891aba07d5e836a3aa5e","size":"17MB","target_guids":[],"type_of_change":"0","version":"5.35.12978.0"}],"id":{"product":"99585b9bf89c4f4eb41d039eef8811c2","version":"cacefc2d3dc3479fafb26a7c8438c4f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Mellanox CX3 驅動程式"},{"lang":"en","x_late":"HPE Mellanox CX3 Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Mellanox CX3 드라이버"},{"lang":"cn","x_late":"用于Windows Server 2016的HPE Mellanox CX3驱动程序"},{"lang":"ja","x_late":"HPE Mellanox CX3ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"8020","subven":"103C","target_guid":"","type":"pci","ven":"15B3"},{"dev":"1004","subdev":"801F","subven":"103C","target_guid":"","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product restores support for the following network adapters:</p>\n\n<ul>\n\t<li>HP Ethernet 10G 2-port 546FLR-SFP+ Adapter</li>\n\t<li>HP Ethernet 10G 2-port 546SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"mlx4_bus.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2012 R2."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2012 R2で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"979440","datemodified":"2020-12-02T17:11:16","file_list":["cp045178.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo36.dll","nicco5.dll","nicdrvr.dll","NicInVXN.dll","vxn64x64.cat","vxn64x64.din","vxn64x64.inf","vxn64x64.sys","vxnmsg.dll"],"md5sum":"3532d65aec4e39cfcb8867e62ff830b1","name":"cp045178.exe","release":"2020-12-02T16:57:22","revision":"0","sha1sum":"d2434ef5cfc096a568788041a5a5418fbe8a6091","size":"956KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5befedc7"],"type_of_change":"0","version":"1.2.199.0"}],"id":{"product":"04dc2cf5b5cc44668cfd3459661fd5db","version":"c62d019301f54441acbfc0bbde4e210f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2012 R2"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2012 R2"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, vxnmsg.dll, nicco5.dll, and nicinvxn.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn64x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.20_10_27_2020.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.20 (10/27/2020)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9061056","datemodified":"2020-11-03T04:48:46","file_list":["cp045752.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_2.20_10_27_2020.signed.flash"],"md5sum":"8d833740b11018e75717b1ddd4a8ed4f","name":"cp045752.exe","release":"2020-11-09T00:00:00","revision":"1","sha1sum":"57a67824021b1c8549e4ad5553bdca6004140f3a","size":"8MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.20_10-27-2020"}],"id":{"product":"c5181c3bc0654e9db312aa6200639426","version":"443e094424f24bc6a65a9be721424bd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-25T03:17:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","latest_fixes_x_late":"<P><B>Important Notes:</B></P>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.<P><B>Firmware Dependencies:</B></P>None<P><B>Problems Fixed:</B></P>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358.  These issues are not unique to HPE servers.<P><B>Known Issues:</B></P>None"},{"curr_enhancements_x_late":"Added a new BIOS/Platform Configuration (RBSU) option to Memory Options called Refresh Watermarks. When selecting the Low Watermark setting, the memory controller will help reduce susceptibility to a DDR4 RowHammer attack. It is expected that a memory performance impact will be seen when enabling the Low Watermark setting. The default operation of the system has not changed and customers wanting to provide additional RowHammer protection should enable this setting.  <p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.<p>Updated the System ROM support for One Button Secure Erase functionality with the latest HPE option devices.<p>Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigations for security vulnerabilities documented as CVE-2020-8696, CVE-2020-8694 and CVE-2020-8695. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00381 and INTEL-SA-00389. The Intel microcode patches included in this release are version 0x000000DE (CPUIDs 906ED, 906EC, 906EB and 906EA). These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0593. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>Addressed an issue where the &quot;Minimum Processor Idle Power Package C-State&quot; RBSU option was missing.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD, and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3528776","datemodified":"2020-12-17T11:33:04","file_list":["cp045509.xml","cpqsetup.exe","payload.json","setup.dll","SVKBPND4.rel"],"md5sum":"95c1988ca23de59b497a58c3d2da58bd","name":"cp045509.exe","release":"2020-12-17T11:18:09","revision":"0","sha1sum":"c20d9f798b9dd95253fd0a6766f96c040fce4f87","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"33a82ad709014bf88daa4d5451b9b3d6","version":"581d8f4184c948aa9adf50bdd6c11888"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:35:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>  Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>      None</p>"}],"files":[{"bytes":"3641304","datemodified":"2020-12-16T18:07:05","file_list":["cp045546.xml","cpqsetup.exe","payload.json","setup.dll","SMKRASD9.rel"],"md5sum":"3322cfe799938602e054f56deafa4f82","name":"cp045546.exe","release":"2020-12-16T17:56:13","revision":"0","sha1sum":"7793bd0ee4e9c22d59d3fb5879d0e081f0a43229","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"fc0a79d6952d41d4919e3578b5303d5a","version":"5241556771f44c028d2e15279f1a1bdc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:48:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8915500","datemodified":"2021-02-09T15:34:45","file_list":["./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"d75c54bee6e7f085b22bd79c80ebf490","name":"mft-4.16.0-105.rhel7u9.x86_64.rpm","release":"2021-02-09T15:27:04","revision":"0","sha1sum":"1d97f86c8c540e4d663234bd32c525e5e9904a55","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"},{"bytes":"17682","datemodified":"2021-02-09T15:36:06","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"cf19ab746e577d4a2bcfbe11f6ae6313","name":"kmod-kernel-mft-mlnx-4.16.0-1.rhel7u9.x86_64.rpm","release":"2021-02-09T15:27:04","revision":"0","sha1sum":"3c0fcf053d84403304b0046c9eaa19e6b326bb50","size":"17KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.16"}],"id":{"product":"7cbddfc3ba97405ea0a71d3635caace8","version":"5c6778e4dc0b44fa959c2b15e80b1463"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.16.0-1.rhel7u9.x86_64.rpm&nbsp;&nbsp;mft-4.16.0-105.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-11T19:55:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"该 Smart Component 可为以下存储控制器提供固件： 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"此智慧型元件提供適用於下列儲存控制器的韌體： Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"이 스마트 구성 요소는 다음 스토리지 컨트롤러용 펌웨어를 제공합니다. 스마트 어레이 P220i, P222, P420i, P420, P421, P721m 및 P822"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。 SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online ROM Flash Component for VMware ESXi - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(D)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 8.32(C)</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for ESXi 7.0</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"25567173","datemodified":"2020-08-28T03:26:38","file_list":["/CP045344.vmexe","/CP045344.vmexe64","/CP045344.vmfile","/CP045344.xml","/payload.json","/README.txt"],"md5sum":"9006f9f9715e6965c8c451717abae65e","name":"CP045344.zip","release":"2020-08-28T03:12:09","revision":"0","sha1sum":"c4ba54d32077a5a85bebc6e650fae4ce0e442f4b","size":"24MB","target_guids":[],"type_of_change":"1","version":"8.32","vib_list":[]}],"id":{"product":"191698dcecb7439eb6e537a0877ed0e1","version":"a6915b77f1284ff488472fe13fc5de03"},"installation":{"command":"CP045344.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActiveIfPresent","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfd368f11","ServerModel":["*"],"Target_guids":[],"Type":"NE","Version":"100.18.2.64","description":"HPE ProLiant Smart Array HPCISSS3 Controller Driver version 100.18.2.64 must not be used for firmware update.  Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run Smart Update Manager (SUM).</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For Smart Update Manager (SUM) 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp; &nbsp; or chmod +x CPXXXXX.vmexe64 (for ESXi7.0)</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe or ./CPXXXXX.vmexe64 (for ESXi7.0)</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - Smart Array P220i, P222, P420i, P420, P421, P721m, and P822"},{"lang":"cn","x_late":"面向 VMware ESXi 的在线 ROM Flash 组件 - 智能阵列 P220i、P222、P420i、P420、P421、P721m 和 P822"},{"lang":"tw","x_late":"適用於 VMware ESXi 的線上 ROM 更新元件 - Smart Array P220i、P222、P420i、P420、P421、P721m 與 P822"},{"lang":"ko","x_late":"VMware ESXi용 온라인 ROM 플래시 구성 요소 - 스마트 어레이 P220i, P222, P420i, P420, P421, P721m, P822"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware ESXi - SmartアレイP220i、P222、P420i、P420、P421、P721m、およびP822"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-24T10:29:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for ESXi 7.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"}],"sw_keys":[{"name":"3355103c","sw_key_expectedpath":"firmware"},{"name":"3352103c","sw_key_expectedpath":"firmware"},{"name":"3356103C","sw_key_expectedpath":"firmware"},{"name":"3351103c","sw_key_expectedpath":"firmware"},{"name":"D2220sb","sw_key_expectedpath":"firmware"},{"name":"3350103c","sw_key_expectedpath":"firmware"},{"name":"3354103c","sw_key_expectedpath":"firmware"},{"name":"3353103c","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GEBTP Drive"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB6000GEBTPドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16541837","datemodified":"2021-01-28T12:15:51","file_list":["/CP045661_BUILD_4.data","/CP045661.vmexe","/CP045661.vmexe64","/CP045661.vmfile","/CP045661_VMw.zip","/CP045661.xml","/payload.json","/CP045661_VMw.zip/index.xml","/CP045661_VMw.zip/vendor-index.xml","/CP045661_VMw.zip/metadata.zip","/CP045661_VMw.zip/vib20/CP045661/HPE_bootbank_CP045661_HPG4.4-7.0.0.15843807.vib","/CP045661_VMw.zip/metadata.zip/vendor-index.xml","/CP045661_VMw.zip/metadata.zip/vmware.xml","/CP045661_VMw.zip/metadata.zip/vibs/CP045661-8641994752990085475.xml","/CP045661_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045661_HPG4.4-7.0.0.15843807.xml"],"md5sum":"6c87e4c3298ae15d33443e443ad49b61","name":"CP045661.zip","release":"2021-01-28T12:13:04","revision":"0","sha1sum":"ad17dbe09c521fd4034b143b4369250990cc776a","size":"15MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP045661","version":"HPG4.4-7.0.0.15843807"}]}],"id":{"product":"f08c2998f0194b1483b2e21050a3b5a3","version":"50b74377044c4844af9358215b794000"},"installation":{"command":"CP040543.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:02:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic NX2/FastLinQ userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8 Update 0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"98142","datemodified":"2019-09-16T13:36:05","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/b4ad24d1483e26abcb54e79e3a95dc25b0ee46","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio/component.xml"],"md5sum":"543f01a33ad8664d14fd4cf91833c6f5","name":"iscsiuio-2.11.5.13-3.rhel8u0.x86_64.rpm","release":"2019-09-16T13:33:02","revision":"0","sha1sum":"1baa30f2290a98600da931ccd13678959de916eb","size":"95KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec563dc806"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"4e575045dc6d4bff9cf8a8d6613b0cd4","version":"035a461dc93142d6a01389a8448efa17"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic iSCSI Offload IO Daemon for Red Hat Enterprise Linux 8 Update 0"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-10-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iscsiuio","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GVYYU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n      </strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"3407040","datemodified":"2020-12-16T17:17:53","file_list":["cp045552.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6TG2.rel"],"md5sum":"9d09b218815940f487381c86b5ee8920","name":"cp045552.exe","release":"2020-12-16T17:07:04","revision":"0","sha1sum":"720c3bdc8fd1d8cafdd97399221861ce83bfdb8f","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"f620be56e3714dd58684aa99e9723c4b","version":"146ac5e072ca46f6b866f700dba59b3a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:50:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEeD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JFHMH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EG1800JFHMH Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"16143639","datemodified":"2021-01-27T16:01:49","file_list":["/CP045615_BUILD_3.data","/CP045615.vmexe","/CP045615.vmexe64","/CP045615.vmfile","/CP045615_VMw.zip","/CP045615.xml","/payload.json","/CP045615_VMw.zip/index.xml","/CP045615_VMw.zip/vendor-index.xml","/CP045615_VMw.zip/metadata.zip","/CP045615_VMw.zip/vib20/CP045615/HPE_bootbank_CP045615_HPD7.3-7.0.0.15843807.vib","/CP045615_VMw.zip/metadata.zip/vendor-index.xml","/CP045615_VMw.zip/metadata.zip/vmware.xml","/CP045615_VMw.zip/metadata.zip/vibs/CP045615--8009202338205285271.xml","/CP045615_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045615_HPD7.3-7.0.0.15843807.xml"],"md5sum":"4a0ea8eec31c0668bed9b31fe8d03e34","name":"CP045615.zip","release":"2021-01-27T15:59:06","revision":"0","sha1sum":"77244b0472b43ca73dec21324635255d937cfade","size":"15MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP045615","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"b013dc662ea446dbabf5ade1d9cf8d6f","version":"27b266f0612947b18f051b09f7249a6b"},"installation":{"command":"CP040626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:19:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：<br />\n     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.00(B)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>SUSE Linux Enterprise Server 15 OSのサポートを追加しました</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点：</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"5246419","datemodified":"2018-09-25T13:59:51","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/CP037610.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/TiogaPass-Release-1.00-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037610.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037610.scexe"],"md5sum":"85ecb6e6cfe6fc900fa01a0c6c0a103e","name":"firmware-smartarray-9f082dffb4-1.00-2.1.x86_64.rpm","release":"2018-10-23T00:00:00","revision":"1","sha1sum":"1737d6844da1dbe5ea5a50bf4691f77f86f99a09","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00"}],"id":{"product":"b59071ade4f9427093d3054145f8756e","version":"f6958296a88d45ea87f64a0f531f8a89"},"installation":{"command":"CP037610.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037610.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-9f082dffb4-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037610.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-9f082dffb4-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP037610.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-smartarray-9f082dffb4-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./CP037610.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*'の場所に<em>./setup</em>を追加してください。</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-9f082dffb4-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong></p>\n\n<p><strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>USB Key Utility for Windows</u></a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux（x64） - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-04T14:11:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD7"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD7"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD7"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD7"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD7"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD7"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD7"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD7"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD7"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD7"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD7"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD7"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD7"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16041094","datemodified":"2021-01-28T13:28:54","file_list":["/CP045688_BUILD_3.data","/CP045688.vmexe","/CP045688.vmexe64","/CP045688.vmfile","/CP045688_VMw.zip","/CP045688.xml","/payload.json","/CP045688_VMw.zip/index.xml","/CP045688_VMw.zip/vendor-index.xml","/CP045688_VMw.zip/metadata.zip","/CP045688_VMw.zip/vib20/CP045688/HPE_bootbank_CP045688_HPD7.3-7.0.0.15843807.vib","/CP045688_VMw.zip/metadata.zip/vendor-index.xml","/CP045688_VMw.zip/metadata.zip/vmware.xml","/CP045688_VMw.zip/metadata.zip/vibs/CP045688-7158150996705377835.xml","/CP045688_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045688_HPD7.3-7.0.0.15843807.xml"],"md5sum":"b736d8a50854cff12e81c13d37d996b0","name":"CP045688.zip","release":"2021-01-28T13:26:05","revision":"0","sha1sum":"40babdd607bd26aaa64e0cf2733fb1803479f9fb","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP045688","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"7004592a3bf74fab99a6fe756662ebbc","version":"0ab6707015ec485bbf88e7376ad6b187"},"installation":{"command":"CP040758.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネント for VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:24:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2213409","datemodified":"2021-02-25T10:49:53","file_list":["/cp045860.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vendor-index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vmware-storcli.vib","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vendor-index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vmware.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vibs/vmware-storcli--8232902898101632508.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/bulletins/HPE-esx-6.7.0-storcli-007.1616.0000.0000.xml"],"md5sum":"0030c84ede3e14d3c0bb8a3f37fba171","name":"cp045860.zip","release":"2021-02-25T10:49:04","revision":"0","sha1sum":"720ea694c1d9d931ecb20138a894b0a648f170f3","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec16a8689d"],"type_of_change":"1","version":"2021.04","vib_list":[{"name":"vmware-storcli","version":"007.1616.0000.0000-01"}]}],"id":{"product":"89a2a097a7fc4af6987e0d04ef00de6a","version":"141e6e7c72144a15a6805876d9b696b2"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7&nbsp;host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Support for maintaining, monitoring and configuring MegaRAID Gen10+ Controllers: MR416i-a, MR416i-p, MR216i-a, MR216i-p</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"vmware-storcli:007.1616.0000.0000","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17406241","datemodified":"2021-01-28T01:46:15","file_list":["/CP045652_BUILD_4.data","/CP045652.vmexe","/CP045652.vmexe64","/CP045652.vmfile","/CP045652_VMw.zip","/CP045652.xml","/payload.json","/CP045652_VMw.zip/index.xml","/CP045652_VMw.zip/vendor-index.xml","/CP045652_VMw.zip/metadata.zip","/CP045652_VMw.zip/vib20/CP045652/HPE_bootbank_CP045652_HPG6.4-7.0.0.15843807.vib","/CP045652_VMw.zip/metadata.zip/vendor-index.xml","/CP045652_VMw.zip/metadata.zip/vmware.xml","/CP045652_VMw.zip/metadata.zip/vibs/CP045652--3409994657381203225.xml","/CP045652_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045652_HPG6.4-7.0.0.15843807.xml"],"md5sum":"86658967418d6becb7cb87685e02cf59","name":"CP045652.zip","release":"2021-01-28T01:43:05","revision":"0","sha1sum":"fdb02b9ae959eeab75bea649cc0c19192de01818","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6","vib_list":[{"name":"CP045652","version":"HPG6.4-7.0.0.15843807"}]}],"id":{"product":"63f9bb70bcb94f2c9378d569ebb38b7e","version":"b3ac0e1a44b6453b9379469977b4ec9e"},"installation":{"command":"CP040642.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"},{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEXYA and MB6000JEXYB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16131870","datemodified":"2021-01-28T12:11:48","file_list":["/CP045660_BUILD_5.data","/CP045660.vmexe","/CP045660.vmexe64","/CP045660.vmfile","/CP045660_VMw.zip","/CP045660.xml","/payload.json","/CP045660_VMw.zip/index.xml","/CP045660_VMw.zip/vendor-index.xml","/CP045660_VMw.zip/metadata.zip","/CP045660_VMw.zip/vib20/CP045660/HPE_bootbank_CP045660_HPD9.5-7.0.0.15843807.vib","/CP045660_VMw.zip/metadata.zip/vendor-index.xml","/CP045660_VMw.zip/metadata.zip/vmware.xml","/CP045660_VMw.zip/metadata.zip/vibs/CP045660--992128675713425699.xml","/CP045660_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045660_HPD9.5-7.0.0.15843807.xml"],"md5sum":"ac93b7601254df86fa64da5a84d6df77","name":"CP045660.zip","release":"2021-01-28T12:09:05","revision":"0","sha1sum":"534fdbd032e64625ef482be88bf00e5ee106d6a4","size":"15MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP045660","version":"HPD9.5-7.0.0.15843807"}]}],"id":{"product":"1bfd9c2e979e4c999fa2978061e8b412","version":"5f68d7d834124fa2bb667b093a5289fe"},"installation":{"command":"CP040533.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:02:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5665807","datemodified":"2021-01-28T09:14:48","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"447ccb91b3ad19b7192a3b2fc94320ce","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel8u3.x86_64.rpm","release":"2021-01-28T08:56:06","revision":"0","sha1sum":"d541b9237bfd9698c9716b01d96ab8f59a81e9e5","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"a970944cf8a44d27bcff8a800d52aa6b","version":"4605a3d3ebb84d00bcacc344d0ff81bf"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial driver for RedHat Enterprise Linux Server&nbsp;8 update 2 version&nbsp;10.01.00.64.08.0-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.7"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.9.0.</p>\n"}],"files":[{"bytes":"219113","datemodified":"2021-01-08T21:28:33","file_list":["/cp045743.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/vib20/i40en/INT_bootbank_i40en_1.10.9.0-1OEM.670.0.0.8169922.vib","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vendor-index.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vmware.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/vibs/i40en-360149877953999718.xml","/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922-offline_bundle-16117660.zip/metadata.zip/bulletins/Intel-i40en_1.10.9.0-1OEM.670.0.0.8169922.xml"],"md5sum":"6b3ca2cf1c09b838ff9a3717263b854f","name":"cp045743.zip","release":"2021-01-08T21:27:05","revision":"0","sha1sum":"a549c957ab899a14bf28b943522291178661860c","size":"213KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"i40en","version":"1.10.9.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"cbfe1835cecf43e391be405d2fc118ca","version":"fb25419d7aab4c0abf1a0a6f1a35810c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel i40enドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which PCI device information passing to intnetcli Command-Line Interface (Intel&reg; ESXCLI Plug-In Managing tool ).</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue obtain PCI addresses information when execution intnet CLI tools.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40en:1.10.9.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17377348","datemodified":"2021-01-28T16:08:49","file_list":["/CP045666_BUILD_3.data","/CP045666.vmexe","/CP045666.vmexe64","/CP045666.vmfile","/CP045666_VMw.zip","/CP045666.xml","/payload.json","/CP045666_VMw.zip/index.xml","/CP045666_VMw.zip/vendor-index.xml","/CP045666_VMw.zip/metadata.zip","/CP045666_VMw.zip/vib20/CP045666/HPE_bootbank_CP045666_HPDB.3-7.0.0.15843807.vib","/CP045666_VMw.zip/metadata.zip/vendor-index.xml","/CP045666_VMw.zip/metadata.zip/vmware.xml","/CP045666_VMw.zip/metadata.zip/vibs/CP045666--2083583419935944900.xml","/CP045666_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045666_HPDB.3-7.0.0.15843807.xml"],"md5sum":"88d9a024631dc0a4b1a8ce6d045abb79","name":"CP045666.zip","release":"2021-01-28T16:05:05","revision":"0","sha1sum":"3125509dd598a8257b0d1b55a0d73a65a5573f06","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP045666","version":"HPDB.3-7.0.0.15843807"}]}],"id":{"product":"1d0e9b382f8640e89092917ac97996ce","version":"7860b153a7d24baf989a922306bac235"},"installation":{"command":"CP040519.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi  - MB6000JEQUV およびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:06:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800215","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"816832","datemodified":"2021-01-22T08:57:50","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp044778.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"8822ab99a9256f332b499a3ef6e56b73","name":"cp044778.zip","release":"2021-01-22T08:57:05","revision":"0","sha1sum":"24c9ecfb6a871fa473900c6ef50c9b2c05427bf3","size":"797KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"0a5c3792d04d4b22a3b657bedf5eaefc","version":"5e77a2ef1f9c4110bdef59afe945ae29"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Driver version 3.1.36.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Mezzanine Host Bus Adapter driver support for HPE Blade Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2096328","datemodified":"2020-12-10T10:31:52","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp042240.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"0e770cb5759b8d8c63072abea7ddf95f","name":"cp042240.exe","release":"2020-12-10T10:27:04","revision":"0","sha1sum":"83b42484755850b0a354d022ae956581b815960a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"44342a3601e1466c9e7b89e65ba92f03","version":"525bf62de5ab4cb8aa743703a25072cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage Mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-19T10:57:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Added support for following:</p>\n\n<p>Updated to driver version 12.0.1192.0</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD5"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"18381593","datemodified":"2021-01-28T08:04:00","file_list":["/CP045640_BUILD_3.data","/CP045640.vmexe","/CP045640.vmexe64","/CP045640.vmfile","/CP045640_VMw.zip","/CP045640.xml","/payload.json","/CP045640_VMw.zip/index.xml","/CP045640_VMw.zip/vendor-index.xml","/CP045640_VMw.zip/metadata.zip","/CP045640_VMw.zip/vib20/CP045640/HPE_bootbank_CP045640_HPD5.3-7.0.0.15843807.vib","/CP045640_VMw.zip/metadata.zip/vendor-index.xml","/CP045640_VMw.zip/metadata.zip/vmware.xml","/CP045640_VMw.zip/metadata.zip/vibs/CP045640-6258049343302533661.xml","/CP045640_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045640_HPD5.3-7.0.0.15843807.xml"],"md5sum":"8214e7ca7414c77eabcd82e0a2d1c331","name":"CP045640.zip","release":"2021-01-28T08:01:06","revision":"0","sha1sum":"04e210111212187673523b4952ccc83c35f0ee04","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"2","version":"HPD5","vib_list":[{"name":"CP045640","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"58002f5fbb3c4bdca0598c03bb921813","version":"78dbc7efc2d84846ad51a0aab8e97e31"},"installation":{"command":"CP040637.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:42:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.Â  This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands. This issue was only found in supplier ongoing lab testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD4"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD4"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp; Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17985715","datemodified":"2021-01-28T16:46:42","file_list":["/CP045979_BUILD_4.data","/CP045979.vmexe","/CP045979.vmexe64","/CP045979.vmfile","/CP045979_VMw.zip","/CP045979.xml","/payload.json","/CP045979_VMw.zip/index.xml","/CP045979_VMw.zip/vendor-index.xml","/CP045979_VMw.zip/metadata.zip","/CP045979_VMw.zip/vib20/CP045979/HPE_bootbank_CP045979_HPD4.4-7.0.0.15843807.vib","/CP045979_VMw.zip/metadata.zip/vendor-index.xml","/CP045979_VMw.zip/metadata.zip/vmware.xml","/CP045979_VMw.zip/metadata.zip/vibs/CP045979-7076866331907835712.xml","/CP045979_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045979_HPD4.4-7.0.0.15843807.xml"],"md5sum":"47bff24ccbd29d0fbbcb33615585a882","name":"CP045979.zip","release":"2021-01-28T16:44:09","revision":"0","sha1sum":"6abddacc06467947b0ad89c22803bed62f9bbaa9","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP045979","version":"HPD4.4-7.0.0.15843807"}]}],"id":{"product":"b1381f6ec67b40269898593ac27aca95","version":"1cf079f4c1b648dd889a1e178a193b88"},"installation":{"command":"CP043266.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加します。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-01T09:43:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update includes a fix that prevents unrecoverable read errors in highly localized write intensive workload, and a new servo code revision that improves performance under specific vibration conditions.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300215","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4170010","datemodified":"2021-01-28T09:52:17","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"36abe6ed691d2fff4175a0636452eaed","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-28T09:40:07","revision":"0","sha1sum":"0f7da71c0ce7179d3c47a4967f0a815da2933c40","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"933e42b273b146ee8ce7b3d90a74c2b2","version":"3bac55d05c7246759fedb7acd77fb04c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3262","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3262","type":"pci","ven":"1077"},{"dev":"2532","subdev":"3263","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2532103c3263","type":"pci","ven":"1077"},{"dev":"2532","subdev":"00FC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2532159000fc","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E7","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e7","type":"pci","ven":"1077"},{"dev":"2031","subdev":"17E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c17e8","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015D","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015d","type":"pci","ven":"1077"},{"dev":"2532","subdev":"015C","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-25321077015c","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-07T08:26:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated driver for:</p>\n\n<p>SuSE Linux Enterprise Server 12 service pack&nbsp;5 (SLES12 sp5) version 10.01.00.64.12.5-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n   Online HDD/SSD Flash Component for Windows (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2930056","datemodified":"2020-12-16T14:16:50","file_list":["cp045565.xml","cpqsetup.exe","payload.json","setup.dll","TAPM4VVEHPD5.rel"],"md5sum":"bc0ac6c181834cea1db8072942cafe05","name":"cp045565.exe","release":"2020-12-16T14:08:04","revision":"0","sha1sum":"1a7dbb9ce19157f9c0ea8b2a20505aa448695848","size":"2MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0d44f7068b8b4ccebd15e4e19fe5c5fa","version":"145f218c38594cffbc95a1aa3f156b70"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:55:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、 LO2000KEFJU、LT0800KEXVA、LT1600KEXVBおよび LT2000KEXVC ドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online NVMe SSD Flash Component for Windows (x64) -  LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n     HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p><strong>   </strong>  Added support for Windows 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"2866504","datemodified":"2021-04-07T10:27:52","file_list":["4IFDHPK4.rel","cp045513.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"7c50f93ffc3a4b8bbf4f857358777746","name":"cp045513.exe","release":"2021-04-07T10:19:18","revision":"0","sha1sum":"49c234bb0c3568af9f6cae13d2cd8af8fdcdcf45","size":"2MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"8f00f37b744a48c992007d0537ca5fe1","version":"9fc97ed54c974096acd65b849ed7c1a9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:37:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1188624","datemodified":"2021-01-09T09:31:44","file_list":["cp045122.xml","cpqsetup.exe","cp_data.xml","e1r65x64.cat","e1r65x64.din","e1r65x64.inf","e1r65x64.sys","e1rmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"a920089969ddeb7083ab889ce100a6cd","name":"cp045122.exe","release":"2021-01-09T09:16:14","revision":"0","sha1sum":"6646894ed231730d8406300b041982386b764328","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac"],"type_of_change":"0","version":"12.16.3.1"}],"id":{"product":"2131145ed95b459da9bb06449e0c1401","version":"af007ed6060b482b92cee7b2f45ba59c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i350 Driver for Windows Server 2016"},{"lang":"ja","x_late":"Intel i350ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"e1r65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD6"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD6"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL and EH000900JWCPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17650072","datemodified":"2021-01-27T17:00:00","file_list":["/CP046301_BUILD_2.data","/CP046301.vmexe","/CP046301.vmexe64","/CP046301.vmfile","/CP046301_VMw.zip","/CP046301.xml","/payload.json","/CP046301_VMw.zip/index.xml","/CP046301_VMw.zip/vendor-index.xml","/CP046301_VMw.zip/metadata.zip","/CP046301_VMw.zip/vib20/CP046301/HPE_bootbank_CP046301_HPD6.2-7.0.0.15843807.vib","/CP046301_VMw.zip/metadata.zip/vendor-index.xml","/CP046301_VMw.zip/metadata.zip/vmware.xml","/CP046301_VMw.zip/metadata.zip/vibs/CP046301-7234201451710495194.xml","/CP046301_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046301_HPD6.2-7.0.0.15843807.xml"],"md5sum":"c9696ef1636261df387fa1056b02c7da","name":"CP046301.zip","release":"2021-01-27T16:57:05","revision":"0","sha1sum":"8a7acb3323ff148acc16818fe84748325b8034f2","size":"16MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP046301","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"070f2ccb66ec4478ba85a2e3d9712434","version":"2336d9615387402b8fabd13a221023ec"},"installation":{"command":"CP040541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-19T12:32:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This update improves performance for random read workloads with delays between reads.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_29_1016-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.29.1016"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter(P23665-B21)</td>\n\t\t\t<td>20.29.1016</td>\n\t\t\t<td>MT_0000000452</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5524012","datemodified":"2021-02-25T13:25:55","file_list":["20_29_1016-MCX653105A-ECA_HPE_Ax.pldm.signed","20_29_1016-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"9adfc819897a9788294c4d44de6d682f","name":"20_29_1016-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","release":"2021-02-25T13:23:05","revision":"0","sha1sum":"bc42e0bc4e06d3b924dc6d964656361b8d25b586","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"type_of_change":"1","version":"20.29.1016"}],"id":{"product":"cca7377cd12644cab41f5bd7e94cc2bd","version":"153ac93d8b554afa839dff52fe01ac49"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-12T10:48:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 20.29.1016:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.29.1016:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"},{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000GWFGH および MB001000GWFGF "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n      </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/NewFeatures :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>       None</p>\n\n<p><strong>Known Issues:</strong><br />\n       None</p>"}],"files":[{"bytes":"3311168","datemodified":"2020-12-17T07:41:28","file_list":["cp045517.xml","cpqsetup.exe","payload.json","setup.dll","SNEMOTG3.rel"],"md5sum":"142a62cfcd4996e5342a1b7921ba1eab","name":"cp045517.exe","release":"2020-12-17T07:29:10","revision":"0","sha1sum":"e925e9350203655630077585d613c49018f52247","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757464746","4d2340a5-3042-3230-3030-304757464748"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"606295772f834fc984488410e9459b3e","version":"80e442ed055b4cf2a7cd9796d4efab1c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000GWFGH and MB001000GWFGF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:38:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.56(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added HPE Smart Array p824i-p controller support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5731776","datemodified":"2018-12-12T14:04:04","file_list":["cp037765.xml","cpqsetup.exe","flash_Exp_1.00.bat","payload.json","setup.bat","setup.dll","storcli64.exe","Talladega-Release-1.56-build-000.bin"],"md5sum":"143ec9be382ba3121af59a7bd7c0cbfd","name":"cp037765.exe","release":"2018-12-12T19:56:04","revision":"0","sha1sum":"1323db26a9c8351b8b23825c5e577fe5915fb5c8","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56"}],"id":{"product":"466714784bac4803a010a4a944178d10","version":"597ef8fdd0c9438da8f7c1eb7edfbc73"},"installation":{"command":"setup.bat","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、\n          </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant:</a>から以下の手順に従ってください</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.bat スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 45xx Gen10 Backplane Expander Firmware "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-03T16:51:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array p824i-p controller support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE Blade QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade QLogic NX2 10/20 GbEマルチファンクションGigabitサーバーアダプタードライバーfor Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>10GbE VBD driver version 7.13.196.0</li>\n\t<li>NDIS 6.0 driver version 7.13.183.0</li>\n\t<li>FCoE offload driver version 7.14.22.0</li>\n\t<li>FCoE crash dump driver version 7.13.6.0</li>\n\t<li>iSCSI offload driver version 7.14.16.0</li>\n\t<li>iSCSI crash dump driver version 7.13.4.0</li>\n</ul>\n"}],"files":[{"bytes":"3403992","datemodified":"2021-02-25T15:58:57","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp045208.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys"],"md5sum":"70feb46971fea44c8a728d48d8182c06","name":"cp045208.exe","release":"2021-02-25T15:42:04","revision":"0","sha1sum":"0b249ce10d6b14c8d5610ffd4fdc07e07c967fdc","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"0","version":"7.13.196.0"}],"id":{"product":"4a7b934c55fe47768eb7c9f45376dbee","version":"2a19e992cf664481a0959883b298c7e4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now privately supports Windows 10.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now provides non-SRIOV NIC switch and UDP hash support for Windows Server 2016.</p>\n","curr_fixes_x_late":"<p>This product corrects a Windows Stop Error (BSOD) seen when uninstalling the NDIS driver.<br />\nThis product corrects a BSOD with error code 7E seen when a system is heavily loaded with network traffic.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG1800JEMDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>       None</p>\n\n<p><strong>Known Issues:<br />\n       </strong>None</p>"}],"files":[{"bytes":"3762968","datemodified":"2020-12-17T12:52:38","file_list":["cp045501.xml","cpqsetup.exe","payload.json","setup.dll","STHBT2D5.rel"],"md5sum":"a638b89ab78a7cc9108037356b5a7bde","name":"cp045501.exe","release":"2020-12-17T12:44:09","revision":"0","sha1sum":"1e7f12c2767ca7e69b46d65c553d3f2072f71c25","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0099c8dbd23e4805b57e681e858e79b9","version":"a446d1edc1154e7490e374e4878243a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:32:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n      HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n     </strong> None</p>"}],"files":[{"bytes":"4232464","datemodified":"2020-12-17T06:40:24","file_list":["cp045521.xml","cpqsetup.exe","HVLAnAsseFD1.rel","payload.json","setup.dll"],"md5sum":"57c26aac98afd1d1956936f2a6ef565e","name":"cp045521.exe","release":"2020-12-17T06:25:08","revision":"0","sha1sum":"db9155d3d71a9c360e3326446646a0c977f424bd","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"96853662d13b4def814a5c153a747271","version":"e6ec9820b4854fc7a4ab64066689ac57"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:39:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for Broadcom NetXtreme-E devices for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2016用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1017632","datemodified":"2021-01-14T09:17:45","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045254.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"529af92643339b8aff039ede88b319cc","name":"cp045254.exe","release":"2021-01-14T09:03:05","revision":"0","sha1sum":"0ab41c01f8b39fde8318f720d1d082b189367a38","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"4db7819f5f294e828ed2663d73c4bc75","version":"ad377dec54a74be9a64df62a6fb23369"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NetXtreme-E Driver for Windows Server 2016"},{"lang":"ja","x_late":"Broadcom NetXtreme-Eドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41593","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41592","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41593","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41592","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41595","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41594","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41597","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41596","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41595","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41597","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41596","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D6","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41593","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41593","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41595","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41594","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41597","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41595","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41594","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41596","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1249760","datemodified":"2021-01-08T21:10:01","file_list":["cp045319.xml","cpqsetup.exe","cp_data.xml","i40ea65.cat","i40ea65.din","i40ea65.inf","i40ea65.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"04993f54636e390568a4d696ffc2b8c3","name":"cp045319.exe","release":"2021-01-08T20:54:04","revision":"0","sha1sum":"c78d59474ccabb8f8cbee342efbaf5f8216f269d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3"],"type_of_change":"0","version":"1.13.104.0"}],"id":{"product":"408cc9357d7a4fdb8b6243b952746726","version":"674cfbdff576400c9578c177df218836"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i40ea Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"}],"sw_keys":[{"name":"i40ea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedentv, version&nbsp;3.11.16.0</li>\n\t<li>qedrntv, version&nbsp;3.11.16.0</li>\n\t<li>qedf, version&nbsp;1.3.42.50</li>\n\t<li>scsi-qedil, version 1.15.15.0</li>\n</ul>\n"}],"files":[{"bytes":"4297259","datemodified":"2021-01-18T03:32:50","file_list":["/cp046222.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedf/QLC_bootbank_qedf_1.3.42.50-1OEM.600.0.0.2768847.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/scsi-qedil/QLC_bootbank_scsi-qedil_1.15.15.0-1OEM.600.0.0.2494585.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vmware.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/bulletins/qedentv-bundle-3.0.201.7_signed.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedrntv--5432460915364582024.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedf-403674252693421673.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedentv--7190238033104912737.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/scsi-qedil--2754727834483470936.xml"],"md5sum":"3baffdf1a90192768387b0996e077de6","name":"cp046222.zip","release":"2021-01-18T03:31:30","revision":"0","sha1sum":"3386889242cc37f94d2a6c517ab3de348470ccff","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec660dedd2","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"type_of_change":"0","version":"2021.04.05","vib_list":[{"name":"qedrntv","version":"3.11.16.0-1OEM.650.0.0.4598673"},{"name":"qedf","version":"1.3.42.50-1OEM.600.0.0.2768847"},{"name":"scsi-qedil","version":"1.15.15.0-1OEM.600.0.0.2494585"},{"name":"qedentv","version":"3.11.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"cc4bfdeb5e654d1bb1a491db23bb09b4","version":"cc1e1edd585648c0adab7dce36affd66"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue where Fibre Channel over Ethernet (FCoE) frame with CRC size and End Of Frame(EOF) size.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue runs out of MSI-X interrupt vectors caused what Purple Screen of Death (PSOD)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"scsi-qedil:1.15.15.0-1OEM.600.0.0.2494585","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:1.3.42.50-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6883239","datemodified":"2020-11-04T23:05:33","file_list":["/CP046176.vmexe","/CP046176.vmfile","/CP046176.xml","/README.txt"],"md5sum":"079bbf9e9fcb94582ae85c6c221a7a7b","name":"CP046176.zip","release":"2020-11-05T05:03:08","revision":"0","sha1sum":"6bcf40075c3639df1254031b451c0ba3b6dd8e80","size":"6MB","target_guids":[],"type_of_change":"1","version":"2.80_10-16-2020","vib_list":[]}],"id":{"product":"8dacb77af98a4fc9af98892b534614a5","version":"224867b02856423e999e6dc25548f5e8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>IMPORTANT: This component requires that the CRU driver be loaded before the component can run.<br />\nThe minimum CRU version for 5.1 is 5.0.3.9.<br />\nThe minimum CRU version for 5.5 is 5.5.4.1.<br />\nThe minimum CRU version for 6.0 is 6.0.8.<br />\nThe minimum CRU version for 6.5 is 6.5.8.<br />\nThe minimum CRU version for 6.7 is 6.7.10.<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>SPP Offline mode boots a special Linux OS environment, thus the Linux Components are used, not the VMware Components</li>\n</ul>\n\n<p><br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run&nbsp;SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>Refer to the SPP documentation for detailed instructions at:&nbsp; <a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong><strong>To update firmware from VMware ESXi operating system on target server:</strong> </strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Component ( CPxxxxxx.zip) in a temporary directory</li>\n\t<li>From the same directory, unzip the Component:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>To perform the standalone installation, execute the command:<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>Follow the directions given by the Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>重要：このコンポーネントは、実行する前にCRUドライバーがロードされている必要があります。<br />\n5.1の最小CRUバージョンは5.0.3.9です。<br />\n5.5の最小CRUバージョンは5.5.4.1です。<br />\n6.0の最小CRUバージョンは6.0.8です。<br />\n6.5の最小CRUバージョンは6.5.8です。<br />\n6.7の最小CRUバージョンは6.7.10です。<br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMwareコンポーネントではなく、Linuxコンポーネントが用いられます</li>\n</ul>\n\n<p><br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<p> </p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします</li>\n\t<li>SPPにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います</li>\n\t<li>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/servers/spp\">www.hpe.com/servers/spp</a></li>\n</ul>\n\n<p><strong><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong> </strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>コンポーネント (CPxxxxxx.zip)を一時ディレクトリに置きます</li>\n\t<li>同じディレクトリからコンポーネントをunzipします:<br />\n\tunzip CPxxxxxx.zip</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：<br />\n\tCPxxxxxx.vmexe</li>\n\t<li>コンポーネントの指示に従います</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>システムを再起動し、ファームウェアのアップデートを有効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware - HPE ProLiant XL450 Gen9 (U21) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for VMware - HPE ProLiant XL450 Gen9（U21）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_operating_systems":[{"major":"5","minor":"1","name":"VMware vSphere 5.1","platform":"vmware_esx_server","sr":"OEM"},{"major":"5","minor":"5","name":"VMware vSphere 5.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-27T07:52:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest support for Intel Trusted eXecution Technology (TXT) which provides mitigation for CVE-2019-151. This mitigation is only needed for systems that have TXT enabled&nbsp;(TXT is disabled by default). This issue is not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code support that provides mitigation for CVE-2019-11137. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Added support to BIOS/Platform Configuration (RBSU) to allow importing and exporting Secure Boot signature lists as a signed binary file. This is useful to import the Microsoft revocation list binary file into the Secure Boot DBX as found on the UEFI forum at https://uefi.org/revocationlistfile.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2020.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the System ROM includes the latest revision of Intel microcode. The Intel microcode patches included in this release are versions 0x00000044 (CPUID 306F2) and 0x00B00003A (CPUID 406F1).</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2020-0591 and CVE-2020-0592. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00358. These issues are not unique to HPE servers.</p>\n\n<p>This revision of the System ROM includes the latest revision of the Intel Reference Code which provides mitigations for BIOS platform code advisories and security vulnerabilities documented as CVE-2020-8738, CVE-2020-8740, and CVE-2020-8764. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00390. These issues are not unique to HPE servers.</p>\n\n<p>This version of the System ROM contains an updated UEFI Driver for the SmartArray B140i SATA RAID controller. This update addresses an issue where the system may periodically experience an operating system boot issue such as experiencing a Linux kernel panic on boot.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"}],"sw_keys":[{"name":"U21","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>None</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"15878112","datemodified":"2021-01-27T12:31:03","file_list":["/CP045610_BUILD_3.data","/CP045610.vmexe","/CP045610.vmexe64","/CP045610.vmfile","/CP045610_VMw.zip","/CP045610.xml","/payload.json","/CP045610_VMw.zip/index.xml","/CP045610_VMw.zip/vendor-index.xml","/CP045610_VMw.zip/metadata.zip","/CP045610_VMw.zip/vib20/CP045610/HPE_bootbank_CP045610_HPD2.3-7.0.0.15843807.vib","/CP045610_VMw.zip/metadata.zip/vendor-index.xml","/CP045610_VMw.zip/metadata.zip/vmware.xml","/CP045610_VMw.zip/metadata.zip/vibs/CP045610-7478476920384627271.xml","/CP045610_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045610_HPD2.3-7.0.0.15843807.xml"],"md5sum":"9558be659713944228af83d6328c5036","name":"CP045610.zip","release":"2021-01-27T12:28:05","revision":"0","sha1sum":"6b90b5663e188c83f24302e63e0b6661005ec64f","size":"15MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP045610","version":"HPD2.3-7.0.0.15843807"}]}],"id":{"product":"4b93b2211c95475cbce045b32636c34c","version":"d8e352da11b34e0d80f8e264d15d3576"},"installation":{"command":"CP040531.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T16:15:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE ProLiant Smart Array Px4x and Hx4x series controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE ProLiant SmartアレイPx4xおよびHx4xシリーズコントローラーを有効にするためのプレビルドバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"77767","datemodified":"2020-11-18T09:55:25","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hpsa","./lib/modules/4.18.0-193.el8.x86_64/extra/hpsa/hpsa.ko","./usr/lib/.build-id","./usr/lib/.build-id/1d","./usr/lib/.build-id/1d/8883af3641f8a33eb973313837b93a2ffc265b","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"68042fe74fe9d69756efc0e6ff3e02c3","name":"kmod-hpsa-3.4.20-203.rhel8u2.x86_64.rpm","release":"2020-11-18T09:43:04","revision":"0","sha1sum":"9eaa2ebda90cd9ed46132725dd4dd5604a061b0b","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-203"},{"bytes":"77758","datemodified":"2020-11-18T09:51:20","file_list":["./etc/depmod.d/hpsa.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hpsa","./lib/modules/4.18.0-240.el8.x86_64/extra/hpsa/hpsa.ko","./usr/lib/.build-id","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/82af689741ba6ca32ab169ec9b5b3df42dbbde","./usr/share/smartupdate/kmod-hpsa/component.xml"],"md5sum":"659d5c503b5ce5b7b9d03b87e7175eb4","name":"kmod-hpsa-3.4.20-203.rhel8u3.x86_64.rpm","release":"2020-11-18T09:43:04","revision":"0","sha1sum":"dc851ad145c367dc2704dc6d5aa85bfcb45b8c99","size":"75KB","target_guids":[],"type_of_change":"1","version":"3.4.20-203"}],"id":{"product":"4f66ba55022c4d27b6cbd8baecfe7d6d","version":"a796c1afb8264186b90e79e967a69a40"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMを<br />\nご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p><strong>ドライバーをインストールまたはアップグレードするには次のようにタイプします。</strong></p>\n\n<ul>\n\t<li># rpm -Uvh kmod-hpsa-<version>.<OSupdate>.x86_64.rpm  </li>\n</ul>\n\n<p style=\"margin-right:0px\">Setup is now complete. コンピューターをただちに再起動してください。</p>\n\n<p><strong>注記</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。</p>\n\n<ul>\n\t<li># rpm -e kmod-hpsa-<version>.<OSupdate>.x86_64.rpm</li>\n</ul>\n\n<p> </p>\n\n<p><strong><u>エンタープライズサポート</u></strong><br />\nSmartアレイコントローラーのサポートに関しては、<a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a>を参照してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 8 (64-bit)"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8（64-bit）用HPE ProLiant Smartアレイコントローラー（64-bit）ドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"323c","subdev":"1928","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1922","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1923","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1926","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3353","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1924","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323c","subdev":"1921","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3355","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3350","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3351","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3354","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323b","subdev":"3352","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"323B","subdev":"3356","subven":"103C","target_guid":"","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-26T15:42:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 8.2</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Red Hat Enterprise Linux 8.3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"P74","value":"HP ProLiant SL140s Gen8 Server (private)"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 v2 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I14","value":"HP ProLiant BL480c Server"}],"sw_keys":[{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hpsa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000GWWQUおよびMB006000GWWQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3754392","datemodified":"2020-12-11T20:53:34","file_list":["cp045584.xml","cpqsetup.exe","payload.json","SCIMARRNETG2.rel","setup.dll"],"md5sum":"ad0b221d0dc0813bf6dde617cd640080","name":"cp045584.exe","release":"2020-12-11T20:32:05","revision":"0","sha1sum":"d849f70225af82173a4f0bf9291bc24b39c9dbd0","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"c65e02b4990e43eea4fa2402b45960eb","version":"08f233ba77d145f5a543911423652281"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:03:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"8732456","datemodified":"2021-01-08T14:11:01","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-193.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"0ed42da5a271c5d4fd1f00e8004e8e0a","name":"kmod-netxtreme2-7.14.76-1.rhel8u2.x86_64.rpm","release":"2021-01-08T13:49:04","revision":"0","sha1sum":"67513855e3cc5ffafba4164207fb54f884ff4a49","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.76-1"},{"bytes":"8930583","datemodified":"2021-01-08T14:13:16","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-235.el8.x86_64","./lib/modules/4.18.0-235.el8.x86_64/extra","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-235.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"5e668bac29f5a734bfe1b8a3a1e1b37f","name":"kmod-netxtreme2-7.14.76-1.rhel8u3.x86_64.rpm","release":"2021-01-08T13:49:04","revision":"0","sha1sum":"3c9b42a69210fa181bbbb6573e4aa7bff914a225","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"0","version":"7.14.76-1"}],"id":{"product":"9f8f92dcaee7444992d11c0fa284d349","version":"e36b80191aea4f34bad8a4bd36c8d3c9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the driver Precision Time Protocol (PTP) is not working due to timestamp problem.</li>\n\t<li>This product addresses an issue where the Firmware installation failure when enabling secure boot under SUSE Linux Enterprise Server 15 SP2.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue obtain Medium Dependent Interface(MDI) and Medium Dependent Interface Crossover (MDIX) information when execution ethtool tools</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1336.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-T Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C8144","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C220A","Version":"12.0.1336.0"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1336.0.ufi","InstallDurationSec":90,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C220A","Version":"12.0.1336.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12899144","datemodified":"2021-01-21T17:58:38","file_list":["/CP042527_BUILD_7.data","/CP042527.vmexe","/CP042527.vmexe64","/CP042527.vmfile","/CP042527_VMw.zip","/CP042527.xml","/payload.json","/CP042527_VMw.zip/index.xml","/CP042527_VMw.zip/vendor-index.xml","/CP042527_VMw.zip/metadata.zip","/CP042527_VMw.zip/vib20/CP042527/HPE_bootbank_CP042527_2021.02.01.7-6.7.0.7535516.vib","/CP042527_VMw.zip/metadata.zip/vendor-index.xml","/CP042527_VMw.zip/metadata.zip/vmware.xml","/CP042527_VMw.zip/metadata.zip/bulletins/Smart-Component-CP042527_2021.02.01.7-6.7.0.7535516.xml","/CP042527_VMw.zip/metadata.zip/vibs/CP042527--7783229411486902542.xml"],"md5sum":"bd8953f95a24313327cab60fe97830c6","name":"CP042527.zip","release":"2021-01-21T17:55:04","revision":"0","sha1sum":"411fc3c539640eb07187adb586f25113b97524a4","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153","a6b1a447-382a-5a4f-10DF-0720103C8144","a6b1a447-382a-5a4f-10DF-0722103C8144","a6b1a447-382a-5a4f-10DF-0724103C8144","a6b1a447-382a-5a4f-10DF-0720103C220A","a6b1a447-382a-5a4f-10DF-0724103C220A","a6b1a447-382a-5a4f-10DF-0722103C220A"],"type_of_change":"1","version":"2021.02.01","vib_list":[{"name":"CP042527","version":"2021.02.01.7-6.7.0.7535516"}]}],"id":{"product":"91d189194b084bd98d6e01e6c3e2ba6d","version":"491835f2059e495bb053fdb25f751726"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:42:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\"><strong>Firmware</strong></p>\n\n<p><strong>Contains:</strong></p>\n\n<p>CNA (XE100 series) firmware 12.0.1280.5</p>\n","latest_fixes_x_late":"<p>Fixed the following:</p>\n\n<p>UEFI:</p>\n\n<ul>\n\t<li>HPE FlexFabric 20Gb 2-port 650FLB Adapter and HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;does not complete&nbsp;to create boot source on 2nd port</li>\n</ul>\n\n<p>Firmware:</p>\n\n<ul>\n\t<li>Light Emiiting Diode(LED) is in&nbsp;invalid state when disable the port under Unified Extensible Firmware Interface (UEFI)</li>\n\t<li>Duplicate Entries found in firmware report under NIC details for few adaptors.</li>\n\t<li>Full adapter name is not displayed for HPE FlexFabric 20Gb 2-port 650M Adapter&nbsp;in some Rom Based Setup Utility (RBSU).</li>\n\t<li>On any HPE ProLiant server configured with the HPE Emulex XE-102 Based network adapter HPE FlexFabric 10Gb 2-port 556FLR-T Adapter with CNA (XE100 series) firmware 12.0.1110.0, 12.0.1110.10, or 12.0.1110.11 (or later), the network adapters may experience a &quot;link down&quot; state that is not recoverable by a power-cycle or reset.</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;For more details please go through the document titled &quot;HPE ProLiant Servers Configured With Certain HPE Emulex XE-102 Based Network Adapters May Experience Link Down Due To a Firmware Issue&quot; at the following link:<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us\" rel=\"noreferrer noopener\" tabindex=\"-1\" target=\"_blank\" title=\"https://support.hpe.com/hpesc/public/docdisplay?docid=emr_na-a00099050en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00099050en_us</a></p>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GVYYU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5251648","datemodified":"2020-12-13T13:58:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/CP045441.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/SMPN6TG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045441.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045441.scexe"],"md5sum":"de0f8668d484f3a697535ee60e8c92ef","name":"firmware-hdd-bdc37cb37f-HPG2-8.1.x86_64.rpm","release":"2020-12-13T13:46:36","revision":"0","sha1sum":"9ce95014f4692e0016d70a2029c77ebe2c1e66f0","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ff74c7c5dcd8491d9c1177c5c1de73f4","version":"74248605ae304cc9ba33ce9cfa233734"},"installation":{"command":"CP040310.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:17:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n      Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n      HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n      None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n      None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n      None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>      None</p>\n\n<p><strong>Known Issues:<br />\n      </strong>None</p>"}],"files":[{"bytes":"4019088","datemodified":"2020-12-17T05:06:45","file_list":["cp045532.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"md5sum":"7c10210efecdf2bbd570a534b926cb37","name":"cp045532.exe","release":"2020-12-17T04:57:04","revision":"0","sha1sum":"1e24746c230c21e88338aa7705f7e269638a5c67","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ed9a4b98eb61471ab66480b22d4e9c4f","version":"8a52fb0b0bab4387bb5c535a30a62090"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:43:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD5"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online HDD/SSD Flash Component for Windows (x64) - MB010000JWAYK and MB008000JWAYH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n      None</p>"}],"files":[{"bytes":"4138640","datemodified":"2020-12-17T05:28:09","file_list":["cp045528.xml","cpqsetup.exe","HLIBRHsseFD5.rel","payload.json","setup.dll"],"md5sum":"614cc586610164ff22ff2298021adf65","name":"cp045528.exe","release":"2020-12-17T05:20:05","revision":"0","sha1sum":"2b04d4448ad88ed629c03d0038a41c3471d45a8c","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"2","version":"HPD5"}],"id":{"product":"e4254455513a49c0ad5f61c79ab13950","version":"064f9174dc2b4c889878bce61029814f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWAYK and MB008000JWAYH Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T14:42:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR, and MS000800KWDUT Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n     Online NVMe SSD Flash Component for Windows (x64) - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n     HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n     None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n     None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n     None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>     Added support for Windows 2019.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>     None</p>\n\n<p><strong>Known Issues:</strong><br />\n     None</p>"}],"files":[{"bytes":"4913576","datemodified":"2021-01-25T06:20:36","file_list":["cp045582.xml","cpqsetup.exe","payload.json","setup.dll","spannmK4.rel"],"md5sum":"257d6d110623d031dc83c5f21b1fd211","name":"cp045582.exe","release":"2021-01-25T06:12:08","revision":"0","sha1sum":"1562e3a4c95b3dfa0053d5cff22fa7ca7c1413e6","size":"4MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"537734d235b44d80ac3623e8cb9c5d5b","version":"1e080cae2b134740afaa658dbcc913b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T15:02:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}}]}